7
HOT BONDER Process Equipment for the Composite Industry AHB380Q V3 For further information, call us at +33 (0) 4.78.86.86.00 or write us at [email protected] 4 ZONES HOT BONDER This dual zone unit is able to operate as four independent single zone units. It is ideal for complex repairs with different materials and sections. Thanks to the slave mode, this unit allows you to repair important areas. This unit is built inside a special case which is light weight and robust. COMPETITIVE ADVANTAGES 9 Thermocouple test / zone 9 Easy Mode TM 9 Data Acquisition 9 Unlimited programs 9 2 Quiet Venturi 9 3 types of report 9 Dual Circuit breaker 9 The only manufacturing to offer the SMS option MAIN FEATURES 9 4 heating connectors 9 8.4” TFT screen 9 32 Amp total 9 20 thermocouples total 9 5 thermocouples per zone 9 2 USB ports 9 Light weight 12Kg OPTIONS 9 SMS Alarm 9 Accessory case: 3 levels 9 64 Amp 9 Calibration software 9 Training IDEAL FOR 9 Multizone and Universal Repairs

Transcript of Aeroform 4 zones hot bonder

Page 1: Aeroform 4 zones hot bonder

H O T B O N D E R P r o c e s s E q u i p m e n t

f o r t h e C o m p o s i t e I n d u s t r y A H B 3 8 0 Q V 3

For further information, call us at +33 (0) 4.78.86.86.00 or write us at [email protected]

4 ZONES HOT BONDER

This dual zone unit is able to operate as four independent single zone units. It is ideal for complex repairs with different materials and sections. Thanks to the slave mode, this unit allows you to repair important areas. This unit is built inside a special case which is light weight and robust.

COMPETITIVE ADVANTAGES 9 Thermocouple test / zone 9 Easy Mode TM 9 Data Acquisition 9 Unlimited programs 9 2 Quiet Venturi 9 3 types of report 9 Dual Circuit breaker 9 The only manufacturing

to offer the SMS option

MAIN FEATURES 9 4 heating connectors 9 8.4” TFT screen 9 32 Amp total 9 20 thermocouples total 9 5 thermocouples per zone 9 2 USB ports 9 Light weight 12Kg

OPTIONS 9 SMS Alarm 9 Accessory case: 3 levels 9 64 Amp 9 Calibration software 9 Training

IDEAL FOR 9 Multizone and Universal

Repairs

Page 2: Aeroform 4 zones hot bonder

H O T B O N D E R P r o c e s s E q u i p m e n t

f o r t h e C o m p o s i t e I n d u s t r y A H B 3 8 0 Q V 3

For further information, call us at +33 (0) 4.78.86.86.00 or write us at [email protected]

4 ZONES HOT BONDER

9 4 independent heating zones : ABCD 9 20 thermocouples total 9 5 thermocouples per zone

Page 3: Aeroform 4 zones hot bonder

H O T B O N D E R P r o c e s s E q u i p m e n t

f o r t h e C o m p o s i t e I n d u s t r y A H B 3 8 0 Q V 3

For further information, call us at +33 (0) 4.78.86.86.00 or write us at [email protected]

EASY MODE TM:

A user without training can run a cure in 2 clicks. You do not need to be logged in.

SPECIFICATIONS & FEATURES:

PHYSICS PROPERTIES Weight 12Kg

Size 525 x 440 x 210 mm Display Type 200mm Full color, High brightness 8,4” TFT screen Input power 100 to 240 VAC self sensing

Input amperage 23 Amp Circuit Breaker 16A on zone AB or CD (total : 32 A)

GFCI 30mA Vacuum Venturi

Vacuum level 900 mbar (26,5 in Hg) Vacuum measurement 2 Thermocouples type J or K

Thermocouples per zone 5 Heating systems Heater mat, IR Lamp, Hot gun

USB Port 2 ports (memory stick and external devices) Printer Matrix printer with paper 57mm width

Click 2 : press to run

Program to be run

Click 1: Select the program among the list

Page 4: Aeroform 4 zones hot bonder

H O T B O N D E R P r o c e s s E q u i p m e n t

f o r t h e C o m p o s i t e I n d u s t r y A H B 3 8 0 Q V 3

For further information, call us at +33 (0) 4.78.86.86.00 or write us at [email protected]

SOFTWARE PROPERTIES Multi languages Yes

Units of measure F°/C° mbar/bar/mmHg/inHg/PSI Password protection 3 levels

Number of dwell 8 Modify a program in

process Yes

Parameters recorded Set point, All thermocouples temperature, vacuum, events and alarms

Frequency recording Every 2 seconds Deselection of

thermocouples during the cure

Yes

Control mode / Zone Hottest, Average, Coldest or TC 1 to 5 Power failure recovery Yes with printed notification

Alarm Color visual and audible designation of all alarm states

Programmable without a personal computer Yes

Number of storable cure programs Unlimited

Number of stored cured data Unlimited

Tracking chart values Yes, during and after the cure Data Acquisition (DAQ) Yes

REPORT Print out Yes

Print interval 1 to 10 000 seconds Number of print out stored

cure data Unlimited

Report type CSV, PDF and print out at once

Report content Show all information about the cure for traceability, including alarms and events logs on PDF format.

ALARM Thermocouples breaks Yes High and low deviation

process Yes

Over Temperature Yes Low vacuum Yes Power failure Yes

Page 5: Aeroform 4 zones hot bonder

H O T B O N D E R P r o c e s s E q u i p m e n t

f o r t h e C o m p o s i t e I n d u s t r y A H B 3 8 0 Q V 3

For further information, call us at +33 (0) 4.78.86.86.00 or write us at [email protected]

ACCESSORIES

SMS Box 1 Data Cable 1

Main Power Cable 1 SIM Card Not included

PHOTOS & PICTURES OPTION SMS:

SMS ALARM Choice of events :

- Out of band - Over temperature - TC problem - 100% heating - Vacuum level - Power failure - End of cure

Yes Yes Yes Yes Yes Yes Yes

Phone number alerted 1 to 5 SMS Test Yes

Check the data curing on process Yes by sending SMS

Alert SMS and audible alarm Type of issue

mentioned in the SMS Yes

Click 1: Press the logo to select the SMS option, before starting the cure

Click 3: Implement mobile numbers

Click 2: Select the types of alarm

SMS Module

Page 6: Aeroform 4 zones hot bonder

H O T B O N D E R P r o c e s s E q u i p m e n t

f o r t h e C o m p o s i t e I n d u s t r y A H B 3 8 0 Q V 3

For further information, call us at +33 (0) 4.78.86.86.00 or write us at [email protected]

PHOTOS & PICTURES:

Cure control on this screen

Analyse the cure in details

Page 7: Aeroform 4 zones hot bonder

H O T B O N D E R P r o c e s s E q u i p m e n t

f o r t h e C o m p o s i t e I n d u s t r y A H B 3 8 0 Q V 3

For further information, call us at +33 (0) 4.78.86.86.00 or write us at [email protected]

1. PDF Format Options of reports

The three different print out of cure results:

2. CSV Format 3. Paper Ticket Format