R[nilil'sPI5 ilD NIilGT SUPTR PlISTIGIIIR ]||R RTIIG DESCRIPTION ADDMIX@ SP75is a ready-to-use liquid admixture designed to produce rheoplastic qualities to concrete. lt contains no chlorides and meetsthe requirements of ASTM C494 (TypeD and G) and BS 5075 for high range water-reducing admixtures. RECOMMENDED FOR . high quality concrete used undernormal conditions . pumped concrete . ready-mixed concrete . hot weather concreting - densely reinforced concrete - mass concrete pours - use with all cements and air-entrainino - admixtures approved underASTM, - AASHTO, CRD and BSI specifications FEATURES / BENEFITS . highreliability . highstrength . lowerpermeability . improved durability . improved pumping. PFRFORMANCE DATA ADDMIX@ SP75 improves compressive strength considerably. Typical results when dosedat 1 L per 100 kg cementis illustrated below: Testing basedon ASTM C494 Maximum Aggregate Size : 20 mm Cement Content : 320 kg/m3 Concrete moist curedat25'C +l- 2'C Note: Testresult may vary depending on site conditions WORKABILITY ADDMIX@ SP75 ensures that rheoplastic concrete remains workable for a predictable extended time. The precise duration of extended workability depends on the temperature, and also on the type of cement, the nature of aggregates and method of transportation. lt is strictly recommended that concrete shouldbe properly curedafterwards particularly in hot and dry climates. PROPERTIES Supply form : Color : liquid Dark brown COMPATIBILITY ADDMIX@ SP75is compatible with all water reducers and air-entraining agents approved under ASTM,AASHTO and BS specifications but it shouldbe dispensed separately intothe concrete mix. lt should only be usedwith water reducers afterspecific testing at the recommended dose rates, as certain combinations of dosages can extendretardation. DOSAGE ADDMIX@ SP75is normally dispensed at a rateof 0.7- 1.2 liters per 100 kg of cement. Other dosages may also be useddepending on the specific working conditions. BostikPhilippines, Inc. (BPl) doesnot advise employing dosageratesoutside the recommended range without trial testing. Consult you local BPI representative for assistance in determining the dosageratefor optimum performance. 137 Age (Days) f Plain concrete I witnnoovtx.zs

Transcript of Addmix SP 75 Midrange Plasticizer Type D and Type G

Page 1: Addmix SP 75 Midrange Plasticizer Type D and Type G

R[nilil'sPI5ilD NIilGT SUPTR PlISTIGIIIR ]||R RTIIG

DESCRIPTIONADDMIX@ SP75 is a ready-to-use l iquid admixturedesigned to produce rheoplastic qualities toconcrete. lt contains no chlorides and meets therequirements of ASTM C494 (Type D and G) andBS 5075 for high range water-reducing admixtures.

RECOMMENDED FOR. high quality concrete used under normalcondit ions

. pumped concrete

. ready-mixed concrete

. hot weather concreting- densely reinforced concrete- mass concrete pours- use with al l cements and air-entrainino- admixtures approved underASTM,- AASHTO, CRD and BSI specifications

FEATURES / BENEFITS. high rel iabi l i ty. high strength. lower permeability. improved durability. improved pumping.

PFRFORMANCE DATAADDMIX@ SP75 improves compressive strengthconsiderably.

Typical results when dosed at 1 L per 100 kgcement is illustrated below:

Testing based on ASTM C494Maximum Aggregate Size : 20 mmCement Content : 320 kg/m3Concrete moist cured at25'C +l- 2'C

Note: Test result may vary depending on sitecondit ions

WORKABILITYADDMIX@ SP75 ensures that rheoplastic concreteremains workable for a predictable extended time.The precise duration of extended workabilitydepends on the temperature, and also on the typeof cement, the nature of aggregates and method oftransportation. lt is strictly recommended thatconcrete should be properly cured afterwardspart icularly in hot and dry cl imates.

PROPERTIESSupply form :Color :

l iquidDark brown

COMPATIBILITYADDMIX@ SP75 is compatible with al l waterreducers and air-entraining agents approved underASTM, AASHTO and BS specifications but itshould be dispensed separately into the concretemix. lt should only be used with water reducersafter specific testing at the recommended doserates, as certain combinations of dosages canextend retardation.

DOSAGEADDMIX@ SP75 is normally dispensed at a rate of0.7- 1.2 l i ters per 100 kg of cement. Other dosagesmay also be used depending on the specif icworking condit ions.

Bost ik Phi l ippines, Inc. (BPl) does not adviseemploying dosage rates outside the recommendedrange without tr ial testing. Consult you local BPIrepresentative for assistance in determining thedosage rate for optimum performance.137

Age (Days)

f Plain concrete I witnnoovtx.zs

Page 2: Addmix SP 75 Midrange Plasticizer Type D and Type G

RATE OF HARDENINGSetting time is influenced by the chemical andphysical composition of the basic ingredients of theconcrete, temperature of the concrete and climateconditions. Trial mixes should be made with jobmaterials to determine the optimum dosagerequired for a specified setting time and a givenstrength requirement.

ADDMIX@ SP75 is introduced into the mixertogether with mixing water. The plasticizing effect orwater reduction is higher if the admixture is addedto the damp concrete after 50 - 70 % of the waterhas been added. The addition of ADDMX@ Sp75to dry aggregate or cement is not recommended asit lowers the plasticizing effect or water reduction.

/^Yi C Mix

PACKAGINGADDMIX@ SP75 is available in 205 liter drums or inbulk.

STORAGEADDMIX@ SP75 must be stored at moderatetemperatures in sealed original drums.

SHELF LIFEADDMIX@ SP75 can be stored for 12 months ifstored as recommended in unopened originalcontainers.

PRECAUTIONSADDMIX@ SP75 does not contain any hazardoussubstances requiring labeling. lt is safe for use withstandard precautions fol lowed i n constructionindustry such as use of hand gloves, safetygoggles, etc.

IMPORTANT REMINDERTechnical Support and Services whenever provided do not constitute

supervisory responsibility. Suggestion or Recommendation made by BplRepresentative either orally or in writing may be followed, modified or

rejected by the owner, engineer or contractor since they, and not BPI areresponsible for carrying out procedures appropriate to specific application.

Bostik Phil ippines, Inc.35/F Raffles Corporate Center. F. Ortioas Jr. Road.0rtigas Business Center, Pasig City 1600, PhilippinesTel. No. (632) 900-5656 .-wwiv. bostik.com.ph