ADDENDUM NO. 2
DATE: August 21, 2019
TO: All Plan Holders
FROM: Elliot Neph, P.E., RS&H Project Manager
RE: Arlington Municipal Airport
2019 Perimeter Fencing Improvements
TxDOT CSJ No.: 1902ARLIN
RS&H Project No. 2270054000
This Addendum is hereby made a part of the Contract Documents, Specifications, and Drawings of the
above referenced project. All other requirements of the original Contract Documents, Specifications, and
Drawings shall remain effective in their respective order. ACKNOWLEDGE RECEIPT OF THIS
ADDENDUM (PAGES 1 THRU 2 PLUS ATTACHMENTS) BY INSERTING ITS NUMBER AND DATE IN
THE PROPOSAL FORM.
A. GENERAL INFORMATION
1. Existing fence along the northeast and southeast portions of the work area currently penetrate
neighboring property boundaries. This addendum modifies the fence layout in these areas such
that they are relocated to the property boundary. Fence schedules and point tables were modified,
with the changes being reflected on four of the fencing plan sheet series.
B. MODIFICATIONS TO CONTRACT DOCUMENTS
1. N/A
C. MODIFICATIONS TO SPECIFICATIONS
1. N/A
D. MODIFICATIONS TO DRAWINGS
1. Replace Drawing Sheet CF102, Fencing Plan (2 of 12), with the attached revised drawing sheet of
the same name and number.
2. Replace Drawing Sheet CF103, Fencing Plan (3 of 12), with the attached revised drawing sheet of
the same name and number.
3. Replace Drawing Sheet CF107, Fencing Plan (7 of 12), with the attached revised drawing sheet of
the same name and number.
4. Replace Drawing Sheet CF108, Fencing Plan (8 of 12), with the attached revised drawing sheet of
the same name and number.
-
4835 LBJ Freeway
Suite 800
Dallas, TX 75244
O 469-857-7749
rsandh.com
ARLINGTON MUNICIPAL AIRPORT ADDENDUM NO. 2 2019 PERIMETER FENCING IMPROVEMENTS August 21, 2019 Page 2 of 2
E. ATTACHMENTS
1. Drawings
a. Revised Drawing Sheet CF102, Fencing Plan (2 of 12)
b. Revised Drawing Sheet CF103, Fencing Plan (3 of 12)
c. Revised Drawing Sheet CF107, Fencing Plan (7 of 12)
d. Revised Drawing Sheet CF108, Fencing Plan (8 of 12)
F. CONTRACTOR’S QUESTIONS
1. Question: To bid this job, does the bidder have to be TXDOT approved?
Answer: No. TxDOT’s Project Manager, Steve Harp, has recommended that bidders
contact Sheri Quinlan and arrange to have their names/companies placed on the project
online bidders list. This may facilitate connecting with other subcontractors or prime
contractors as needed.
ADDENDUM NO. 2 ISSUED BY:
RS&H, INC.
August 21, 2019
Elliot Neph, P.E.
END OF ADDENDUM NO. 2
-
XX
(6')
XX
(6')
XX
(6')
^
^
^
^
^
^
^^
^^
^^
^^
^^
^^
^^
^^
^
^
^
^
^
^
^^
^^
^^
^^
^^
^^
^^
^^
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
WD
F (6')
WD
F (6')
WD
F (6')
W
D
F
(6
')
W
D
F
(6
')
W
D
F
(6
')
W
D
F
(6
')
W
D
F
(6
')
WD
F
WD
F
WD
F
WD
F
W
D
F
W
D
F
W
D
F
W
D
F
W
D
F
WDF
WDF
WDF
WDF
WDF
W
D
F
G
G
G
G
G
G
G
G
G
GG
GG
G
E(O
H)
E(O
H)
E(O
H)
E(O
H)
E(O
H)
E(O
H)
E(O
H)
E(O
H)
E(O
H)
E(O
H)
E(O
H)
201
202
203
204
205
206
207
208
209
210
211
213
PROTECT EXISTING NAVAID IN-PLACE
PROTECT EXISTING COMMUNICATIONS
STRUCTURE IN-PLACE (TYP.)
PROTECT EXISTING ELECTRICAL
STRUCTURE IN-PLACE (TYP.)
PROTECT EXISTING GAS
LINE IN-PLACE (TYP.)
INSTALL NEW CORNER
POST AND RE-CONNECT
EXISTING FENCE TO REMAIN
212
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE BETWEEN
FENCE LOCATION ID 211 AND 301 WILL NOT
FOLLOW EXISTING FENCE ALIGNMENT, AND
MUST BE RELOCATED ACCORDING TO THE
FENCE LOCATION ID'S PROVIDED. VERIFY
LOCATION OF PROPOSED SECURITY FENCE
IN THE FIELD IN CONJUNCTION WITH THE
OWNER AND ENGINEER (OR RPR)
POINT TABLE
FENCE LOCATION ID
202
203
204
205
206
207
208
209
210
211
212
301
NORTHING
6931358.66
6931362.31
6931410.20
6931394.46
6931373.86
6931260.76
6931255.41
6931226.63
6931214.60
6931215.00
6931215.02
6930529.26
EASTING
2399969.50
2399985.08
2400195.16
2400416.52
2400524.65
2400684.63
2400929.91
2400954.88
2400965.44
2401000.21
2401001.39
2401007.35
PLO
T D
AT
E:
8/16/2019 2:58:10 P
M, S
cott, G
raem
eC
:\pw
_w
ork\rsh_pw
\scottg\d0248591
FILE
P
AT
H:
CF
100.dw
g
FILE
N
AM
E:
NO. DATE REVISION
SHEET NUMBER
APPROVED BY: EBN
ISSUE DATE: AUGUST 21, 2019
DRAWN BY: GDS
2019 PERIMETER FENCING
IMPROVEMENTS
ARLINGTON MUNICIPAL AIRPORT
5000 SOUTH COLLINS STREET
ARLINGTON, TX 76018
TBPE REGISTRATION NO. F-3401
4835 LYNDON B JOHNSON FWY
DALLAS, TX 75244
SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL SIZE 22 X 34 SHEET.
2
08/21/2019 ADDENDUM #2
FENCING PLAN (2 OF 12)
CF102
(12 OF 34)
MATCH LINE (SEE SHEET CF103)MATCH LINE (SEE SHEET CF101)
HORIZ SCALE IN FEET
0100'50'25'
N
PRINT SHEET IN COLOR
EXISTING EASEMENT
LEGEND
X
X (4'D)
X (6'D)
XX (6')
XX (4')
WDF
^^ ^^
XX
EXISTING FENCE TO REMAIN
EXISTING 4' FENCE TO BE REMOVED
EXISTING 6' FENCE TO BE REMOVED
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
EXISTING 4' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
PROPOSED WILDLIFE DETERRENT FENCE
PROPOSED BARBED WIRE MOUNTED
ON TOP OF EXISTING FENCE
PROPOSED SECURITY FENCE
NOTES
1. UNLESS OTHERWISE NOTED IN THE PLANS, NEW FENCE MUST BE INSTALLED
ALONG THE EXACT SAME ALIGNMENT AS EXISTING FENCE REMOVED.
COORDINATES HAVE ONLY BEEN PROVIDED FOR AREAS OF NEW FENCE
ALIGNMENTS OR NEW FEATURES (I.E. GATES, ETC.).
2. NO EXISTING PAVEMENT MARKINGS ARE SCHEDULED TO BE REMOVED OR
ADDED AS A PART OF THIS PROJECT. PROTECT ALL MARKINGS IN THE
VICINITY OF THE PROPOSED FENCE IN-PLACE. REPAINT AT NO EXPENSE TO
THE OWNER ALL MARKINGS DAMAGED BY THE CONTRACTOR. CONFIRM
REQUIREMENTS WITH THE ENGINEER PRIOR TO REPLACEMENT.
3. ALL EXISTING UTILITIES MAY NOT BE SHOWN IN PLAN. PROTECT ALL
EXISTING UTILITIES IN-PLACE UNLESS OTHERWISE SHOWN. SEE GENERAL
UTILITY NOTES ON SHEET G-003.
4. PROPOSED "NO ENTRY PERMITTED" SIGNS MUST BE SPACED NO MORE
THAN 400 FEET APART ON ALL SECURITY FENCE. EACH STRAIGHT SEGMENT
OF FENCE AND PEDESTRIAN / VEHICLE GATES MUST CONTAIN AT LEAST ONE
"NO ENTRY PERMITTED" SIGN. PLACEMENT OF THE PROPOSED "NO ENTRY
PERMITTED" SIGNS IN PLAN ARE APPROXIMATE, AND SHOULD BE
COORDINATED WITH THE OWNER AND ENGINEER (OR RPR) PRIOR TO
PLACEMENT.
5. CONFIRM THE ACTUAL LOCATION OF THE EXISTING / PROPOSED FENCE IN
THE FIELD IN CONJUNCTION WITH THE OWNER AND ENGINEER (OR RPR).
6. SEE SHEETS G-102 THROUGH G-103 FOR BARRICADE PLACEMENT
REQUIREMENTS.
EXISTING DRAINAGE STRUCTURE
EXISTING SANITARY SEWER STRUCTURE
EXISTING FIRE HYDRANT
EXISTING POTABLE WATER STRUCTURE
EXISTING ELECTRICAL STRUCTURE
EXISTING COMMUNICATIONS STRUCTURE
EXISTING STORM LINE
GEXISTING GAS LINE
EXISTING SANITARY SEWER LINE
PROPOSED PEDESTRIAN SWING GATE
PROPOSED MANUAL ACCESS VEHICLE SWING GATE
PROPOSED "NO ENTRY PERMITTED" SIGN
#
FENCE LOCATION ID
APPROXIMATE CLEARING AND GRUBBING
LIMITS (MIN. 10' BOTH SIDES OF FENCE)
WDF (6')
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED WILDLIFE DETERRENT FENCE
W EXISTING WATER LINE
E(OH)EXISTING OVERHEAD ELECTRICAL LINE
PROPOSED CONTRACTOR ACCESS ROUTE
!!! COORDINATE WITH OWNER TO
HAVE FAA MARK UNDERGROUND
UTILITIES PRIOR TO PERFORMING
ANY WORK - DO NOT ENTER
WORK AREA WITHOUT PRIOR
WRITTEN APPROVAL FROM FAA !!!
FENCE SCHEDULE
LOCATION ID DESCRIPTION
101 TO 202
EXISTING 6' FENCE TO BE REPLACED WITH PROPOSED
WILDLIFE DETERRENT FENCE
202 TO 203 PROPOSED MANUAL ACCESS VEHICLE SWING GATE
203 TO 204
EXISTING 6' FENCE TO BE REPLACED WITH PROPOSED
WILDLIFE DETERRENT FENCE
204 TO 209 PROPOSED WILDLIFE DETERRENT FENCE
209 TO 210 PROPOSED MANUAL ACCESS VEHICLE SWING GATE
210 TO 211 PROPOSED WILDLIFE DETERRENT FENCE
211 TO 212 PROPOSED SECURITY FENCE
212 TO 213
PROPOSED BARBED WIRE MOUNTED ON TOP OF
EXISTING FENCE
211 TO 301
EXISTING 6' FENCE TO BE REPLACED WITH PROPOSED
SECURITY FENCE
2
2
2
2
August 21, 2019
-
X
X
(6
')
X
X
(6
')
X
X
(6
')
X
X
(6
')
X
X
(6
')
X
X
(6
')
X
X
(6
')
X
X
(6
')
X
X
(6
')
XX (6')XX (6')
XX (6')XX (6')
XX (6')XX (6')
XX (6')XX (6')
X
X
X
X
X
X
X
X
X
X
XX
XX
XX
XX
GG
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
E
(O
H
)
E
(O
H
)
E
(O
H
)
E(O
H)
E(O
H)
E(O
H)
E
(O
H
)
E
(O
H
)
E
(O
H
)
E(O
H)
E(OH)
E(OH)
E(OH)
E(OH)
E(OH)E(OH)
E(OH)E(OH)
E(OH)E(OH)
E(OH)
302
REPLACE CORNER POST
AND RE-CONNECT EXISTING
FENCE TO REMAIN
PROTECT EXISTING
OVERHEAD ELECTRICAL
LINE IN-PLACE
301
EXISTING 6' FENCE TO BE REPLACED WITH PROPOSED SECURITY FENCE
BETWEEN FENCE LOCATION ID 301 AND 302 WILL NOT FOLLOW EXISTING
FENCE ALIGNMENT, AND MUST BE RELOCATED ACCORDING TO THE FENCE
LOCATION ID'S PROVIDED. VERIFY LOCATION OF PROPOSED SECURITY FENCE
IN THE FIELD IN CONJUNCTION WITH THE OWNER AND ENGINEER (OR RPR)
EXISTING 6' FENCE TO BE REPLACED WITH PROPOSED SECURITY FENCE
BETWEEN FENCE LOCATION ID 211 AND 301 WILL NOT FOLLOW EXISTING
FENCE ALIGNMENT, AND MUST BE RELOCATED ACCORDING TO THE FENCE
LOCATION ID'S PROVIDED. VERIFY LOCATION OF PROPOSED SECURITY FENCE
IN THE FIELD IN CONJUNCTION WITH THE OWNER AND ENGINEER (OR RPR)
POINT TABLE
FENCE LOCATION ID
211
301
NORTHING
6931215.00
6930529.26
EASTING
2401000.21
2401007.35
PLO
T D
AT
E:
8/16/2019 2:58:25 P
M, S
cott, G
raem
eC
:\pw
_w
ork\rsh_pw
\scottg\d0248591
FILE
P
AT
H:
CF
100.dw
g
FILE
N
AM
E:
NO. DATE REVISION
SHEET NUMBER
APPROVED BY: EBN
ISSUE DATE: AUGUST 21, 2019
DRAWN BY: GDS
2019 PERIMETER FENCING
IMPROVEMENTS
ARLINGTON MUNICIPAL AIRPORT
5000 SOUTH COLLINS STREET
ARLINGTON, TX 76018
TBPE REGISTRATION NO. F-3401
4835 LYNDON B JOHNSON FWY
DALLAS, TX 75244
SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL SIZE 22 X 34 SHEET.
2
08/21/2019 ADDENDUM #2
FENCING PLAN (3 OF 12)
CF103
(13 OF 34)
S
O
U
T
H
C
O
L
L
I
N
S
S
T
R
E
E
T
T
A
X
IW
A
Y
A
MA
TC
H L
IN
E (S
EE
S
HE
ET
C
F1
02)
MATCH LINE (SEE SHEET CF104)
N
HORIZ SCALE IN FEET
0100'50'25'
PRINT SHEET IN COLOR
EXISTING EASEMENT
LEGEND
X
X (4'D)
X (6'D)
XX (6')
XX (4')
WDF
^^ ^^
XX
EXISTING FENCE TO REMAIN
EXISTING 4' FENCE TO BE REMOVED
EXISTING 6' FENCE TO BE REMOVED
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
EXISTING 4' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
PROPOSED WILDLIFE DETERRENT FENCE
PROPOSED BARBED WIRE MOUNTED
ON TOP OF EXISTING FENCE
PROPOSED SECURITY FENCE
NOTES
1. UNLESS OTHERWISE NOTED IN THE PLANS, NEW FENCE MUST BE INSTALLED
ALONG THE EXACT SAME ALIGNMENT AS EXISTING FENCE REMOVED.
COORDINATES HAVE ONLY BEEN PROVIDED FOR AREAS OF NEW FENCE
ALIGNMENTS OR NEW FEATURES (I.E. GATES, ETC.).
2. NO EXISTING PAVEMENT MARKINGS ARE SCHEDULED TO BE REMOVED OR
ADDED AS A PART OF THIS PROJECT. PROTECT ALL MARKINGS IN THE
VICINITY OF THE PROPOSED FENCE IN-PLACE. REPAINT AT NO EXPENSE TO
THE OWNER ALL MARKINGS DAMAGED BY THE CONTRACTOR. CONFIRM
REQUIREMENTS WITH THE ENGINEER PRIOR TO REPLACEMENT.
3. ALL EXISTING UTILITIES MAY NOT BE SHOWN IN PLAN. PROTECT ALL
EXISTING UTILITIES IN-PLACE UNLESS OTHERWISE SHOWN. SEE GENERAL
UTILITY NOTES ON SHEET G-003.
4. PROPOSED "NO ENTRY PERMITTED" SIGNS MUST BE SPACED NO MORE
THAN 400 FEET APART ON ALL SECURITY FENCE. EACH STRAIGHT SEGMENT
OF FENCE AND PEDESTRIAN / VEHICLE GATES MUST CONTAIN AT LEAST ONE
"NO ENTRY PERMITTED" SIGN. PLACEMENT OF THE PROPOSED "NO ENTRY
PERMITTED" SIGNS IN PLAN ARE APPROXIMATE, AND SHOULD BE
COORDINATED WITH THE OWNER AND ENGINEER (OR RPR) PRIOR TO
PLACEMENT.
5. CONFIRM THE ACTUAL LOCATION OF THE EXISTING / PROPOSED FENCE IN
THE FIELD IN CONJUNCTION WITH THE OWNER AND ENGINEER (OR RPR).
6. SEE SHEETS G-102 THROUGH G-103 FOR BARRICADE PLACEMENT
REQUIREMENTS.
EXISTING DRAINAGE STRUCTURE
EXISTING SANITARY SEWER STRUCTURE
EXISTING FIRE HYDRANT
EXISTING POTABLE WATER STRUCTURE
EXISTING ELECTRICAL STRUCTURE
EXISTING COMMUNICATIONS STRUCTURE
EXISTING STORM LINE
GEXISTING GAS LINE
EXISTING SANITARY SEWER LINE
PROPOSED PEDESTRIAN SWING GATE
PROPOSED MANUAL ACCESS VEHICLE SWING GATE
PROPOSED "NO ENTRY PERMITTED" SIGN
#
FENCE LOCATION ID
APPROXIMATE CLEARING AND GRUBBING
LIMITS (MIN. 10' BOTH SIDES OF FENCE)
WDF (6')
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED WILDLIFE DETERRENT FENCE
W EXISTING WATER LINE
E(OH)EXISTING OVERHEAD ELECTRICAL LINE
PROPOSED CONTRACTOR ACCESS ROUTE
FENCE SCHEDULE
LOCATION ID DESCRIPTION
211 TO 301
EXISTING 6' FENCE TO BE
REPLACED WITH PROPOSED
SECURITY FENCE
301 TO 302
EXISTING 6' FENCE TO BE
REPLACED WITH PROPOSED
SECURITY FENCE
THIS AREA PREVIOUSLY CLEARED - NO CLEARING AND
GRUBBING REQUIRED EXCEPT FOR EXISTING 6' FENCE
TO BE REPLACED WITH PROPOSED SECURITY FENCE
2
2
2
August 21, 2019
-
XX
(6')
XX (6')XX (6')
XX (6')XX (6') XX
(6') XX (6')
XX (6') XX (6') XX (6') XX (6') XX (6')
XX
(6')
XX
(6')
XX
(6')
XX (6') XX (6') XX (6') XX (6') XX (6') XX (6') XX (6') XX (6')
XX (6')XX (6')
XX (6')XX (6')
XX (6')
XX
(6')
XX (6')
X X
X
X
701
702
PROTECT EXISTING GATE IN-PLACE
PROTECT EXISTING WATER
STRUCTURES IN-PLACE (TYP.)
PROTECT EXISTING FENCE IN-PLACE
PROTECT EXISTING
STRUCTURES IN-PLACE (TYP.)
703
704
705
706
EXISTING GATE
POSTS TO REMAIN
707
708
709
EXISTING 6' FENCE TO BE REPLACED WITH PROPOSED SECURITY FENCE
BETWEEN FENCE LOCATION ID 707 AND 708 WILL NOT FOLLOW EXISTING
FENCE ALIGNMENT, AND MUST BE RELOCATED ACCORDING TO THE FENCE
LOCATION ID'S PROVIDED. VERIFY LOCATION OF PROPOSED SECURITY FENCE
IN THE FIELD IN CONJUNCTION WITH THE OWNER AND ENGINEER (OR RPR)
EXISTING 6' FENCE TO BE REPLACED WITH PROPOSED SECURITY FENCE
BETWEEN FENCE LOCATION ID 708 AND 709 WILL NOT FOLLOW EXISTING
FENCE ALIGNMENT, AND MUST BE RELOCATED ACCORDING TO THE FENCE
LOCATION ID'S PROVIDED. VERIFY LOCATION OF PROPOSED SECURITY FENCE
IN THE FIELD IN CONJUNCTION WITH THE OWNER AND ENGINEER (OR RPR)
EXISTING 6' FENCE TO BE REPLACED WITH PROPOSED SECURITY FENCE
BETWEEN FENCE LOCATION ID 709 AND 801 WILL NOT FOLLOW EXISTING
FENCE ALIGNMENT, AND MUST BE RELOCATED ACCORDING TO THE FENCE
LOCATION ID'S PROVIDED. VERIFY LOCATION OF PROPOSED SECURITY FENCE
IN THE FIELD IN CONJUNCTION WITH THE OWNER AND ENGINEER (OR RPR)
POINT TABLE
FENCE LOCATION ID
707
708
709
801
NORTHING
6924305.09
6923830.38
6923830.06
6923384.00
EASTING
2402956.64
2402956.15
2402742.42
2402742.62
PLO
T D
AT
E:
8/16/2019 2:58:35 P
M, S
cott, G
raem
eC
:\pw
_w
ork\rsh_pw
\scottg\d0248591
FILE
P
AT
H:
CF
100.dw
g
FILE
N
AM
E:
NO. DATE REVISION
SHEET NUMBER
APPROVED BY: EBN
ISSUE DATE: AUGUST 21, 2019
DRAWN BY: GDS
2019 PERIMETER FENCING
IMPROVEMENTS
ARLINGTON MUNICIPAL AIRPORT
5000 SOUTH COLLINS STREET
ARLINGTON, TX 76018
TBPE REGISTRATION NO. F-3401
4835 LYNDON B JOHNSON FWY
DALLAS, TX 75244
SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL SIZE 22 X 34 SHEET.
2
08/21/2019 ADDENDUM #2
FENCING PLAN (7 OF 12)
CF107
(17 OF 34)
SOUTH COLLINS STREET
MA
TC
H L
IN
E (S
EE
S
HE
ET
C
F1
08)
M
A
T
C
H
L
I
N
E
(
S
E
E
S
H
E
E
T
C
F
1
0
6
)
N
HORIZ SCALE IN FEET
0100'50'25'
PRINT SHEET IN COLOR
EXISTING EASEMENT
LEGEND
X
X (4'D)
X (6'D)
XX (6')
XX (4')
WDF
^^ ^^
XX
EXISTING FENCE TO REMAIN
EXISTING 4' FENCE TO BE REMOVED
EXISTING 6' FENCE TO BE REMOVED
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
EXISTING 4' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
PROPOSED WILDLIFE DETERRENT FENCE
PROPOSED BARBED WIRE MOUNTED
ON TOP OF EXISTING FENCE
PROPOSED SECURITY FENCE
NOTES
1. UNLESS OTHERWISE NOTED IN THE PLANS, NEW FENCE MUST BE INSTALLED
ALONG THE EXACT SAME ALIGNMENT AS EXISTING FENCE REMOVED.
COORDINATES HAVE ONLY BEEN PROVIDED FOR AREAS OF NEW FENCE
ALIGNMENTS OR NEW FEATURES (I.E. GATES, ETC.).
2. NO EXISTING PAVEMENT MARKINGS ARE SCHEDULED TO BE REMOVED OR
ADDED AS A PART OF THIS PROJECT. PROTECT ALL MARKINGS IN THE
VICINITY OF THE PROPOSED FENCE IN-PLACE. REPAINT AT NO EXPENSE TO
THE OWNER ALL MARKINGS DAMAGED BY THE CONTRACTOR. CONFIRM
REQUIREMENTS WITH THE ENGINEER PRIOR TO REPLACEMENT.
3. ALL EXISTING UTILITIES MAY NOT BE SHOWN IN PLAN. PROTECT ALL
EXISTING UTILITIES IN-PLACE UNLESS OTHERWISE SHOWN. SEE GENERAL
UTILITY NOTES ON SHEET G-003.
4. PROPOSED "NO ENTRY PERMITTED" SIGNS MUST BE SPACED NO MORE
THAN 400 FEET APART ON ALL SECURITY FENCE. EACH STRAIGHT SEGMENT
OF FENCE AND PEDESTRIAN / VEHICLE GATES MUST CONTAIN AT LEAST ONE
"NO ENTRY PERMITTED" SIGN. PLACEMENT OF THE PROPOSED "NO ENTRY
PERMITTED" SIGNS IN PLAN ARE APPROXIMATE, AND SHOULD BE
COORDINATED WITH THE OWNER AND ENGINEER (OR RPR) PRIOR TO
PLACEMENT.
5. CONFIRM THE ACTUAL LOCATION OF THE EXISTING / PROPOSED FENCE IN
THE FIELD IN CONJUNCTION WITH THE OWNER AND ENGINEER (OR RPR).
6. SEE SHEETS G-102 THROUGH G-103 FOR BARRICADE PLACEMENT
REQUIREMENTS.
EXISTING DRAINAGE STRUCTURE
EXISTING SANITARY SEWER STRUCTURE
EXISTING FIRE HYDRANT
EXISTING POTABLE WATER STRUCTURE
EXISTING ELECTRICAL STRUCTURE
EXISTING COMMUNICATIONS STRUCTURE
EXISTING STORM LINE
GEXISTING GAS LINE
EXISTING SANITARY SEWER LINE
PROPOSED PEDESTRIAN SWING GATE
PROPOSED MANUAL ACCESS VEHICLE SWING GATE
PROPOSED "NO ENTRY PERMITTED" SIGN
#
FENCE LOCATION ID
APPROXIMATE CLEARING AND GRUBBING
LIMITS (MIN. 10' BOTH SIDES OF FENCE)
WDF (6')
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED WILDLIFE DETERRENT FENCE
W EXISTING WATER LINE
E(OH)EXISTING OVERHEAD ELECTRICAL LINE
PROPOSED CONTRACTOR ACCESS ROUTE
FENCE SCHEDULE
LOCATION ID DESCRIPTION
604 TO 701
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
701 TO 702
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
701 TO 703
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
704 TO 705
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
705 TO 706
PROPOSED BARBED WIRE MOUNTED ON TOP OF
EXISTING GATE
706 TO 707
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
707 TO 708
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
708 TO 709
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
709 TO 801
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
2
2
2
August 21, 2019
-
XX
(6')
XX (6') XX (6')XX (6') XX (6')
XX (6') XX (6')XX (6') XX (6')
XX (6') XX (6')
XX (6')XX (6')
XX (6')XX (6')
XX (6')
XX
(6')
XX
(6')
XX
(6')
XX
(6')
XX
(6')
XX
(6')
XX
(6')
XX
(6')
XX
(6')
X
X
X
X
X
X
X
W
D
F
W
D
F
W
D
F
W
D
F
E(O
H)
E(O
H)
E(O
H)
E(O
H)
805
E
S
T
R
U
C
T
U
R
E
I
N
P
L
A
C
E
(
T
Y
P
.
)
PROTECT EXISTING
OVERHEAD ELECTRICAL LINES
AND POLES IN-PLACE (TYP.)
PROTECT EXISTING VEHICLE ACCESS GATE IN-PLACE
PROTECT EXISTING DRAINAGE STRUCTURES IN-PLACE (TYP.)
PROTECT EXISTING ELECTRICAL STRUCTURE IN-PLACE (TYP.)
PROTECT EXISTING NAVAIDS IN-PLACE (TYP.)
INSTALL EROSION CONTROL LOGS WHILE WORKING IN THIS AREA (SEE DETAIL 3 ON SHEET G-501)
SEE DETAIL 1 ON SHEET CF507 FOR DITCH CROSSING
TEMPORARY FENCING IS NOT REQUIRED
FOR INSTALLATION OF WILDLIFE
EXCLUSION FENCE EXCEPT AS
NECESSARY TO SECURE CONNECTION
POINT TO SECURITY FENCE
804
803
EXISTING GATE
POSTS TO REMAIN
902
903
904
905
SEE INSET A FOR IMAGE OF EXISTING LARGE DITCH CROSSING
801
802
EXISTING 6' FENCE TO BE REPLACED WITH PROPOSED SECURITY
FENCE BETWEEN FENCE LOCATION ID 709 AND 801 WILL NOT
FOLLOW EXISTING FENCE ALIGNMENT, AND MUST BE RELOCATED
ACCORDING TO THE FENCE LOCATION ID'S PROVIDED. VERIFY
LOCATION OF PROPOSED SECURITY FENCE IN THE FIELD IN
CONJUNCTION WITH THE OWNER AND ENGINEER (OR RPR)
EXISTING 6' FENCE TO BE REPLACED WITH PROPOSED SECURITY
FENCE BETWEEN FENCE LOCATION ID 801 AND 802 WILL NOT
FOLLOW EXISTING FENCE ALIGNMENT, AND MUST BE RELOCATED
ACCORDING TO THE FENCE LOCATION ID'S PROVIDED. VERIFY
LOCATION OF PROPOSED SECURITY FENCE IN THE FIELD IN
CONJUNCTION WITH THE OWNER AND ENGINEER (OR RPR)
POINT TABLE
FENCE LOCATION ID
709
801
802
805
902
NORTHING
6923830.06
6923384.00
6923382.18
6923397.43
6923470.49
EASTING
2402742.42
2402742.62
2402389.64
2401463.86
2401454.22
PLO
T D
AT
E:
8/16/2019 2:58:44 P
M, S
cott, G
raem
eC
:\pw
_w
ork\rsh_pw
\scottg\d0248591
FILE
P
AT
H:
CF
100.dw
g
FILE
N
AM
E:
NO. DATE REVISION
SHEET NUMBER
APPROVED BY: EBN
ISSUE DATE: AUGUST 21, 2019
DRAWN BY: GDS
2019 PERIMETER FENCING
IMPROVEMENTS
ARLINGTON MUNICIPAL AIRPORT
5000 SOUTH COLLINS STREET
ARLINGTON, TX 76018
TBPE REGISTRATION NO. F-3401
4835 LYNDON B JOHNSON FWY
DALLAS, TX 75244
SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL SIZE 22 X 34 SHEET.
2
08/21/2019 ADDENDUM #2
FENCING PLAN (8 OF 12)
CF108
(18 OF 34)
MATCH LINE (SEE SHEET CF107)
M
A
T
C
H
L
I
N
E
(
S
E
E
S
H
E
E
T
C
F
1
0
9
)
HORIZ SCALE IN FEET
0100'50'25'
N
PRINT SHEET IN COLOR
EXISTING EASEMENT
LEGEND
X
X (4'D)
X (6'D)
XX (6')
XX (4')
WDF
^^ ^^
XX
EXISTING FENCE TO REMAIN
EXISTING 4' FENCE TO BE REMOVED
EXISTING 6' FENCE TO BE REMOVED
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
EXISTING 4' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
PROPOSED WILDLIFE DETERRENT FENCE
PROPOSED BARBED WIRE MOUNTED
ON TOP OF EXISTING FENCE
PROPOSED SECURITY FENCE
NOTES
1. UNLESS OTHERWISE NOTED IN THE PLANS, NEW FENCE MUST BE INSTALLED
ALONG THE EXACT SAME ALIGNMENT AS EXISTING FENCE REMOVED.
COORDINATES HAVE ONLY BEEN PROVIDED FOR AREAS OF NEW FENCE
ALIGNMENTS OR NEW FEATURES (I.E. GATES, ETC.).
2. NO EXISTING PAVEMENT MARKINGS ARE SCHEDULED TO BE REMOVED OR
ADDED AS A PART OF THIS PROJECT. PROTECT ALL MARKINGS IN THE
VICINITY OF THE PROPOSED FENCE IN-PLACE. REPAINT AT NO EXPENSE TO
THE OWNER ALL MARKINGS DAMAGED BY THE CONTRACTOR. CONFIRM
REQUIREMENTS WITH THE ENGINEER PRIOR TO REPLACEMENT.
3. ALL EXISTING UTILITIES MAY NOT BE SHOWN IN PLAN. PROTECT ALL
EXISTING UTILITIES IN-PLACE UNLESS OTHERWISE SHOWN. SEE GENERAL
UTILITY NOTES ON SHEET G-003.
4. PROPOSED "NO ENTRY PERMITTED" SIGNS MUST BE SPACED NO MORE
THAN 400 FEET APART ON ALL SECURITY FENCE. EACH STRAIGHT SEGMENT
OF FENCE AND PEDESTRIAN / VEHICLE GATES MUST CONTAIN AT LEAST ONE
"NO ENTRY PERMITTED" SIGN. PLACEMENT OF THE PROPOSED "NO ENTRY
PERMITTED" SIGNS IN PLAN ARE APPROXIMATE, AND SHOULD BE
COORDINATED WITH THE OWNER AND ENGINEER (OR RPR) PRIOR TO
PLACEMENT.
5. CONFIRM THE ACTUAL LOCATION OF THE EXISTING / PROPOSED FENCE IN
THE FIELD IN CONJUNCTION WITH THE OWNER AND ENGINEER (OR RPR).
6. SEE SHEETS G-102 THROUGH G-103 FOR BARRICADE PLACEMENT
REQUIREMENTS.
EXISTING DRAINAGE STRUCTURE
EXISTING SANITARY SEWER STRUCTURE
EXISTING FIRE HYDRANT
EXISTING POTABLE WATER STRUCTURE
EXISTING ELECTRICAL STRUCTURE
EXISTING COMMUNICATIONS STRUCTURE
EXISTING STORM LINE
GEXISTING GAS LINE
EXISTING SANITARY SEWER LINE
PROPOSED PEDESTRIAN SWING GATE
PROPOSED MANUAL ACCESS VEHICLE SWING GATE
PROPOSED "NO ENTRY PERMITTED" SIGN
#
FENCE LOCATION ID
APPROXIMATE CLEARING AND GRUBBING
LIMITS (MIN. 10' BOTH SIDES OF FENCE)
WDF (6')
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED WILDLIFE DETERRENT FENCE
W EXISTING WATER LINE
E(OH)EXISTING OVERHEAD ELECTRICAL LINE
PROPOSED CONTRACTOR ACCESS ROUTE
FENCE SCHEDULE
LOCATION ID DESCRIPTION
706 TO 801
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
801 TO 802
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
802 TO 803
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
804 TO 805
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
805 TO 901
EXISTING 6' FENCE TO BE REPLACED WITH
PROPOSED SECURITY FENCE
805 TO 902 PROPOSED WILDLIFE DETERRENT FENCE
SOUTHEAST GREEN OAKS BOULEVARD
!!! COORDINATE WITH OWNER TO
HAVE FAA MARK UNDERGROUND
UTILITIES PRIOR TO PERFORMING
ANY WORK - DO NOT ENTER
WORK AREA WITHOUT PRIOR
WRITTEN APPROVAL FROM FAA !!!
INSET A
2
2
2
2
2
2
August 21, 2019