Acurlite Structural Skylights, Inc. for Commercial Daylighting - ALL … · 2020. 6. 3. · USE...
Transcript of Acurlite Structural Skylights, Inc. for Commercial Daylighting - ALL … · 2020. 6. 3. · USE...
ISOMETRIC VIEW
DOUBLE PITCHW/ GABLE END C.H.M.
DRAWN BY:
K.A.M.CHECKED BY:
DATE - ISSUE:
SHEET:
SCALE:
STANDARDSYSTEMDETAILS
PLE
ASE
NO
TEA
LL D
ETA
ILS
AS
SHO
WN
ARE
FO
R RE
FERE
NC
EO
NLY
AN
D S
UBJE
CT
TO C
HAN
GE
PER
AC
URLI
TE P
ROJE
CT
PRO
POSA
L, S
PEC
IFIC
SITE
CO
ND
ITIO
NS,
AC
URLI
TE P
.E. A
NA
LYSI
S, A
ND
GO
VER
NIN
G C
OD
E RE
QUI
REM
ENTS
.
11/30/17 - A
© 570.
759.
6882
w
ww
.acu
rlit
e.co
m
sale
s@ac
urlit
e.co
m
NO
V 3
0, 2
017
SAMPLE
N.T.S.
INSULATED CLOSURE - FOR ADDITIONAL COST(Factory Assembly Includes Rigid Insulation & Formed Backer)
ALUM. GLASS REST & SILICONE SETTING BLOCK(Located At Quarter Points - 2 Per Bay)
SILICONE GASKET
BACKER ROD & CONTINUOUS SEAL
EXTRUDED ALUMINUM PURLIN(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)
FASTEN PURLIN ASSEMBLY TO RAFTER
EXTRUDED ALUMINUM RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)
TYPICAL DETAIL
CURB MUST RESIST ALL LOADS/REACTIONSIMPOSED BY SKYLIGHT
(Reactions Provided By Acurlite P.E.)(Responsible E.O.R. to Verify and Approve)
SILL LUG(Lug Size, Type & Locations Per Acurlite P.E. Analysis)
30.26°712
D1
INSTALLATION
FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL
EXTRUDED ALUM. COVER CAP & PRESSURE CAP W/ GASKET
INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)
INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS
(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Provided For Additional Cost)
ISOLATION/WATERPROOF MEMBRANE(Not By Acurlite - Provided By Others)
FASTEN RAFTER ASSEMBLY TO LUGS - IF REQ.
FULL BEARING SHIM - IF REQUIRED(1/4" Max. Shim Space Typical - Unless Noted Otherwise)(Not by Acurlite - Provided By Others)
MINERAL WOOL TO FILL VOIDS - FOR ADDITIONAL COST(Standard Batt Type - Installer To Ensure System Weep Path Is NOT Blocked)
FASTEN SILL LUG TO CURB(Seal In & Around Lug & Fastener)
INSTALL SILL PAN IN BED OF SEALANT
SPONGE GASKET - FACTORY APPLIED TO SILL PAN(3/4" Void At System Weep As Required)
FORMED EXTERIOR CLOSURE - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)
(Typical Splice Shown As Dashed Line - Locate As Required)
SILL
DETAILS AS SHOWN ARE TYPICAL & FOR REFERENCE(Consult Factory for Additional Modification & Performance Improvements)
CURB SHOULD BE PLUMB, LEVEL & SQUAREPER INDUSTRY STANDARD TOLERANCES
(Max Allowed ±1/8" PER 12' - 0" - Unless Noted Otherwise)(Not By Acurlite - Provided By Others)
PLEASE NOTE
ALL ROOFING, TERMINATION BARS, REGLETS,COUNTER FLASHINGS & FLASHINGS NOT
INTEGRAL TO SKYLIGHT SYSTEM FUNCTION(Not By Acurlite - Provided By Others)
STRUCTURAL SEAL FLANGE - IF REQUIRED(Factory Applied To Purlin - 1/4-20 x 3/4" Flat Head Screw)
DETAILS / MATERIALS PER CONTRACT DOCUMENTS(Not By Acurlite - Provided By Others)
FORMED SILL PAN - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)
APPLY CONT. STRUCTURAL SEAL - IF REQUIRED
PROPER SUBSTRATE REQUIRED FOR ATTACHMENT(Not By Acurlite - Provided By Others)
FASTEN EXTERIOR CLOSURE TO SILL PAN(Use #10 x 1/2" Pan Head S.M.S. - Locate 12" O.C. Typical)
FASTEN EXTERIOR CLOSURE TO PURLIN / FLANGE
USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)
FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)
OPTIONS FOR THERMAL ENHANCEMENT
SNAP ON COVER CAP(Not Required For Water Tightness)
CURB / SUBSTRUCTURE BY OTHERS
STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)
SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory For Your Project Specific Requirements)
OPTIONS FOR VISUAL ENHANCEMENT
VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)
C.H.M.
DRAWN BY:
K.A.M.CHECKED BY:
DATE - ISSUE:
SHEET:
SCALE:
STANDARDSYSTEMDETAILS
PLE
ASE
NO
TEA
LL D
ETA
ILS
AS
SHO
WN
ARE
FO
R RE
FERE
NC
EO
NLY
AN
D S
UBJE
CT
TO C
HAN
GE
PER
AC
URLI
TE P
ROJE
CT
PRO
POSA
L, S
PEC
IFIC
SITE
CO
ND
ITIO
NS,
AC
URLI
TE P
.E. A
NA
LYSI
S, A
ND
GO
VER
NIN
G C
OD
E RE
QUI
REM
ENTS
.
11/30/17 - A
© 570.
759.
6882
w
ww
.acu
rlit
e.co
m
sale
s@ac
urlit
e.co
m
NO
V 3
0, 2
017
D1
6" = 1' - 0"
BACKER ROD & CONTINUOUS SEAL
FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)
OPTIONS FOR VISUAL ENHANCEMENT
FASTEN PURLIN ASSEMBLY TO RAFTER
USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)30.26°7
12
INSTALLATION
APPLY CONT. STRUCTURAL SEAL - IF REQUIRED
INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS
(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Can Be Provided For Additional Cost)
SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory For Your Project Specific Requirements)
STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)
EXTRUDED ALUM. PURLIN(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)
SILICONE GASKET
ALUM. GLASS REST & SILICONE SETTING BLOCK(Located At Quarter Points - 2 Per Bay)
EXTRUDED ALUM. RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)
INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)
STRUCTURAL SEAL FLANGE FASTENED TO PURLIN(Factory Applied To Purlin - 1/4-20 x 3/4" Flat Head Screw)
VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)
FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL
SNAP ON COVER CAP(Not Required For Water Tightness)
PURLINTYPICAL DETAIL
D2 C.H.M.
DRAWN BY:
K.A.M.CHECKED BY:
DATE - ISSUE:
SHEET:
SCALE:
STANDARDSYSTEMDETAILS
PLE
ASE
NO
TEA
LL D
ETA
ILS
AS
SHO
WN
ARE
FO
R RE
FERE
NC
EO
NLY
AN
D S
UBJE
CT
TO C
HAN
GE
PER
AC
URLI
TE P
ROJE
CT
PRO
POSA
L, S
PEC
IFIC
SITE
CO
ND
ITIO
NS,
AC
URLI
TE P
.E. A
NA
LYSI
S, A
ND
GO
VER
NIN
G C
OD
E RE
QUI
REM
ENTS
.
11/30/17 - A
© 570.
759.
6882
w
ww
.acu
rlit
e.co
m
sale
s@ac
urlit
e.co
m
NO
V 3
0, 2
017
D2
6" = 1' - 0"
TYPICAL DETAILRIDGE
D3
FASTEN EXTERIOR CLOSURE TO PURLIN / FLANGE
FASTEN PURLIN ASSEMBLIES TO RAFTER
FASTEN RAFTER ASSEMBLIES TOGETHER - IF REQ.(Gusset Factory Applied to (1) Rafter Assembly Of Each Pair)
BACKER ROD & CONTINUOUS SEAL
USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)
APPLY CONT. STRUCTURAL SEAL - IF REQUIRED
FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)
INSTALLATION
SNAP ON COVER CAP(Not Required For Water Tightness)
FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL
INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)
30.26°712
MINERAL WOOL TO FILL VOIDS - FOR ADDITIONAL COST(Standard Batt Type - Installer To Ensure System Weep Path Is NOT Blocked)
INSULATED CLOSURE - FOR ADDITIONAL COST(Factory Assembly Includes Rigid Insulation & Formed Backer)
FORMED EXTERIOR CLOSURE - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)(Typical Splice Shown As Dashed Line - Locate As Required)
SILICONE GASKET
EXTRUDED ALUMINUM PURLIN(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)
EXTRUDED ALUMINUM RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)
DETAILS AS SHOWN ARE TYPICAL & FOR REFERENCE(Consult Factory for Additional Modification & Performance Improvements)
EXTRUDED ALUM. COVER CAP & PRESSURE CAP W/ GASKET
STRUCTURAL SEAL FLANGE - IF REQUIRED(Factory Applied To Purlin - 1/4-20 x 3/4" Flat Head Screw)
OPTIONS FOR THERMAL ENHANCEMENT
INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Provided For Additional Cost)
STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)
OPTIONS FOR VISUAL ENHANCEMENT
SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory For Your Project Specific Requirements)
VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)
ALUMINUM GUSSET PLATES(Size, Thickness & Type Per Acurlite P.E. Analysis)
C.H.M.
DRAWN BY:
K.A.M.CHECKED BY:
DATE - ISSUE:
SHEET:
SCALE:
STANDARDSYSTEMDETAILS
PLE
ASE
NO
TEA
LL D
ETA
ILS
AS
SHO
WN
ARE
FO
R RE
FERE
NC
EO
NLY
AN
D S
UBJE
CT
TO C
HAN
GE
PER
AC
URLI
TE P
ROJE
CT
PRO
POSA
L, S
PEC
IFIC
SITE
CO
ND
ITIO
NS,
AC
URLI
TE P
.E. A
NA
LYSI
S, A
ND
GO
VER
NIN
G C
OD
E RE
QUI
REM
ENTS
.
11/30/17 - A
© 570.
759.
6882
w
ww
.acu
rlit
e.co
m
sale
s@ac
urlit
e.co
m
NO
V 3
0, 2
017
D3
6" = 1' - 0"
TYPICAL DETAILJAMB
D4
CURB SHOULD BE PLUMB, LEVEL & SQUAREPER INDUSTRY STANDARD TOLERANCES
(Max Allowed ±1/8" PER 12' - 0" - Unless Noted Otherwise)(Not By Acurlite - Provided By Others)
CURB MUST RESIST ALL LOADS/REACTIONSIMPOSED BY SKYLIGHT
(Reactions Provided By Acurlite P.E.)(Responsible E.O.R. to Verify and Approve)
PLEASE NOTE
ALL ROOFING, TERMINATION BARS, REGLETS,COUNTER FLASHINGS & FLASHINGS NOT
INTEGRAL TO SKYLIGHT SYSTEM FUNCTION(Not By Acurlite - Provided By Others)
SILICONE GASKETEXTRUDED ALUM. PURLIN(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)
EXTRUDED ALUM. RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)
INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Can Be Provided For Additional Cost)
STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)
OPTIONS FOR VISUAL ENHANCEMENT
SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory for your project specific needs)
EXTRUDED ALUM. COVER CAP& PRESSURE CAP W/ GASKET
VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)
CURB / SUBSTRUCTURE BY OTHERS
ISOLATION/WATERPROOF MEMBRANE(Not By Acurlite - Provided By Others)
DETAILS / MATERIALS PER CONTRACT DOCUMENTS(Not By Acurlite - Provided By Others)
PROPER SUBSTRATE REQUIRED FOR ATTACHMENT(Not By Acurlite - Provided By Others)
COUNTER FLASHING & REGLETS(Not By Acurlite - Provided By Others)
USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)
FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)
SNAP ON COVER CAP(Not Required For Water Tightness)
INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)
FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL
FASTEN EXTERIOR CLOSURE TO CURB(Shim & Seal As Required)
INSTALLATION
LAP MEMBRANE INTO SYSTEM(Not By Acurlite - Provided By Others)
FORMED EXTERIOR CLOSURE - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)(Typical Splice Shown As Dashed Line - Locate As Required)
FASTEN EXTERIOR CLOSURE TO ANGLE SPACER(Not By Acurlite - Provided By Others)
FORMED ANGLE SPACER - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)(Factory Applied To Rafter)
FASTEN PURLIN ASSEMBLY TO RAFTERBACKER ROD & CONTINUOUS SEAL
C.H.M.
DRAWN BY:
K.A.M.CHECKED BY:
DATE - ISSUE:
SHEET:
SCALE:
STANDARDSYSTEMDETAILS
PLE
ASE
NO
TEA
LL D
ETA
ILS
AS
SHO
WN
ARE
FO
R RE
FERE
NC
EO
NLY
AN
D S
UBJE
CT
TO C
HAN
GE
PER
AC
URLI
TE P
ROJE
CT
PRO
POSA
L, S
PEC
IFIC
SITE
CO
ND
ITIO
NS,
AC
URLI
TE P
.E. A
NA
LYSI
S, A
ND
GO
VER
NIN
G C
OD
E RE
QUI
REM
ENTS
.
11/30/17 - A
© 570.
759.
6882
w
ww
.acu
rlit
e.co
m
sale
s@ac
urlit
e.co
m
NO
V 3
0, 2
017
D4
6" = 1' - 0"
USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)
FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)
FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL
SILICONE GASKET
INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS
(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Can Be Provided For Additional Cost)
FASTEN PURLIN ASSEMBLY TO RAFTER
EXTRUDED ALUM. PURLIN(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)
INSTALLATIONOPTIONS FOR VISUAL ENHANCEMENT
EXTRUDED ALUM. RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)
STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)
INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)
SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory for your project specific needs)
EXTRUDED ALUM. COVER CAP& PRESSURE CAP W/ GASKET
SNAP ON COVER CAP(Not Required for Water tightness)
VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)
ALUM. GUSSET PLATES(Size & Type Per Acurlite P.E. Analysis)
FASTEN RAFTER ASSEMBLIES TOGETHER - IF REQ.(Gusset Factory Applied to (1) Rafter Assembly Of Each Pair)
RAFTERTYPICAL DETAIL
D5
C.H.M.
DRAWN BY:
K.A.M.CHECKED BY:
DATE - ISSUE:
SHEET:
SCALE:
STANDARDSYSTEMDETAILS
PLE
ASE
NO
TEA
LL D
ETA
ILS
AS
SHO
WN
ARE
FO
R RE
FERE
NC
EO
NLY
AN
D S
UBJE
CT
TO C
HAN
GE
PER
AC
URLI
TE P
ROJE
CT
PRO
POSA
L, S
PEC
IFIC
SITE
CO
ND
ITIO
NS,
AC
URLI
TE P
.E. A
NA
LYSI
S, A
ND
GO
VER
NIN
G C
OD
E RE
QUI
REM
ENTS
.
11/30/17 - A
© 570.
759.
6882
w
ww
.acu
rlit
e.co
m
sale
s@ac
urlit
e.co
m
NO
V 3
0, 2
017
D5
6" = 1' - 0"
GABLE HEADD6
TYPICAL DETAIL
SILICONE GASKETEXTRUDED ALUM. PURLIN
(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)
EXTRUDED ALUM. RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)
INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS
(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Can Be Provided For Additional Cost)
STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)
OPTIONS FOR VISUAL ENHANCEMENT
SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory for your project specific needs)
EXTRUDED ALUM. COVER CAP& PRESSURE CAP W/ GASKET
VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)
MINERAL WOOL TO FILL VOIDS - FOR ADDITIONAL COST(Standard Batt Type - Installer To Ensure System Weep Path Is NOT Blocked)
INSULATED CLOSURE - FOR ADDITIONAL COST(Factory Assembly Includes Rigid Insulation & Formed Alum. Backer)
DETAILS AS SHOWN ARE TYPICAL & FOR REFERENCE(Consult Factory for Additional Modification & Performance Improvements)
OPTIONS FOR THERMAL ENHANCEMENT
FASTEN HEAD LUG TO RAFTER(Seal In & Around Lug & Fastener)
FASTEN EXTERIOR CLOSURE TO PURLIN / FLANGE
FORMED EXTERIOR CLOSURE - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)
(Typical Splice Shown As Dashed Line - Locate As Required)
INSTALLATION
USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)
INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)
GABLE HEAD LUG(Lug Size, Type & Locations Per Acurlite P.E. Analysis)
FASTEN RAFTER ASSEMBLY TO LUGS - IF REQ.
FASTEN PURLIN ASSEMBLY TO RAFTER
FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL
SNAP ON COVER CAP(Not Required For Water Tightness)
FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)
C.H.M.
DRAWN BY:
K.A.M.CHECKED BY:
DATE - ISSUE:
SHEET:
SCALE:
STANDARDSYSTEMDETAILS
PLE
ASE
NO
TEA
LL D
ETA
ILS
AS
SHO
WN
ARE
FO
R RE
FERE
NC
EO
NLY
AN
D S
UBJE
CT
TO C
HAN
GE
PER
AC
URLI
TE P
ROJE
CT
PRO
POSA
L, S
PEC
IFIC
SITE
CO
ND
ITIO
NS,
AC
URLI
TE P
.E. A
NA
LYSI
S, A
ND
GO
VER
NIN
G C
OD
E RE
QUI
REM
ENTS
.
11/30/17 - A
© 570.
759.
6882
w
ww
.acu
rlit
e.co
m
sale
s@ac
urlit
e.co
m
NO
V 3
0, 2
017
D6
6" = 1' - 0"
TYPICAL DETAILGABLE SILL
D7
CURB SHOULD BE PLUMB, LEVEL & SQUAREPER INDUSTRY STANDARD TOLERANCES
(Max Allowed ±1/8" PER 12' - 0" - Unless Noted Otherwise)(Not By Acurlite - Provided By Others)
CURB MUST RESIST ALL LOADS/REACTIONSIMPOSED BY SKYLIGHT
(Reactions Provided By Acurlite P.E.)(Responsible E.O.R. to Verify and Approve)
PLEASE NOTE
ALL ROOFING, TERMINATION BARS, REGLETS,COUNTER FLASHINGS & FLASHINGS NOT
INTEGRAL TO SKYLIGHT SYSTEM FUNCTION(Not By Acurlite - Provided By Others)
ISOLATION/WATERPROOF MEMBRANE(Not By Acurlite - Provided By Others)
PROPER SUBSTRATE REQUIRED FOR ATTACHMENT(Not By Acurlite - Provided By Others)
DETAILS / MATERIALS PER CONTRACT DOCUMENTS(Not By Acurlite - Provided By Others)
CURB / SUBSTRUCTURE BY OTHERS
FORMED EXTERIOR CLOSURE - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)(Typical Splice Shown As Dashed Line - Locate As Required)
SILL LUG(Lug Size, Type & Locations Per Acurlite P.E. Analysis)
STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)
SPONGE GASKET - FACTORY APPLIED TO SILL PAN(3/4" Void At System Weep As Required)
INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Can Be Provided For Additional Cost)
EXTRUDED ALUM. PURLIN(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)
SILICONE GASKET
FORMED ANGLE SPACER - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)(Factory Applied To Purlin)
SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory for your project specific needs)
EXTRUDED ALUM. COVER CAP& PRESSURE CAP W/ GASKET
FORMED SILL PAN - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)
ALUM. GLASS REST & SILICONE SETTING BLOCK(Located At Quarter Points - 2 Per Bay)
EXTRUDED ALUM. RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)
OPTIONS FOR VISUAL ENHANCEMENT
VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)
FULL BEARING SHIM - IF REQUIRED(1/4" Max. Shim Space Typical - Unless Noted Otherwise)
(Not by Acurlite - Provided By Others)
INSTALLATION
INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)
FASTEN PURLIN ASSEMBLY TO RAFTER
FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL
FASTEN RAFTER ASSEMBLY TO LUGS - IF REQ.
INSTALL SILL PAN IN BED OF SEALANT
FASTEN SILL LUG TO CURB(Seal In & Around Lug & Fastener)
FASTEN EXTERIOR CLOSURE TO SILL PAN(Use #10 x 1/2" Pan Head S.M.S. - Locate 12" O.C. Typical)
FASTEN EXTERIOR CLOSURE TO ANGLE SPACER(Use Pop Rivets As Required)
FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)
USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)
SNAP ON COVER CAP(Not Required For Water Tightness)
C.H.M.
DRAWN BY:
K.A.M.CHECKED BY:
DATE - ISSUE:
SHEET:
SCALE:
STANDARDSYSTEMDETAILS
PLE
ASE
NO
TEA
LL D
ETA
ILS
AS
SHO
WN
ARE
FO
R RE
FERE
NC
EO
NLY
AN
D S
UBJE
CT
TO C
HAN
GE
PER
AC
URLI
TE P
ROJE
CT
PRO
POSA
L, S
PEC
IFIC
SITE
CO
ND
ITIO
NS,
AC
URLI
TE P
.E. A
NA
LYSI
S, A
ND
GO
VER
NIN
G C
OD
E RE
QUI
REM
ENTS
.
11/30/17 - A
© 570.
759.
6882
w
ww
.acu
rlit
e.co
m
sale
s@ac
urlit
e.co
m
NO
V 3
0, 2
017
D7
6" = 1' - 0"
TYPICAL DETAILGABLE POST
D8
SILICONE GASKETEXTRUDED ALUM. PURLIN
(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)
EXTRUDED ALUM. RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)
INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS
(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Can Be Provided For Additional Cost)
STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)
OPTIONS FOR VISUAL ENHANCEMENT
SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory for your project specific needs)
VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)
FORMED SILL PAN - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)
EXTRUDED ALUM. COVER CAP& PRESSURE CAP W/ GASKET
SILL LUG(Lug Size, Type & Locations Per Acurlite P.E. Analysis)
USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)
FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)
SNAP ON COVER CAP(Not Required For Water Tightness)
INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)
FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL
INSTALLATION
FASTEN PURLIN ASSEMBLY TO RAFTER
FULL BEARING SHIM - IF REQUIRED(1/4" Max. Shim Space Typical - Unless Noted Otherwise)(Not by Acurlite - Provided By Others)
FASTEN RAFTER ASSEMBLY TO LUGS - IF REQ.
FASTEN SILL LUG TO CURB(Seal In & Around Lug & Fastener)
INSTALL SILL PAN IN BED OF SEALANT
SILL CURB - INSIDE EDGE(Not Provided By Acurlite - Provided By Others)
C.H.M.
DRAWN BY:
K.A.M.CHECKED BY:
DATE - ISSUE:
SHEET:
SCALE:
STANDARDSYSTEMDETAILS
PLE
ASE
NO
TEA
LL D
ETA
ILS
AS
SHO
WN
ARE
FO
R RE
FERE
NC
EO
NLY
AN
D S
UBJE
CT
TO C
HAN
GE
PER
AC
URLI
TE P
ROJE
CT
PRO
POSA
L, S
PEC
IFIC
SITE
CO
ND
ITIO
NS,
AC
URLI
TE P
.E. A
NA
LYSI
S, A
ND
GO
VER
NIN
G C
OD
E RE
QUI
REM
ENTS
.
11/30/17 - A
© 570.
759.
6882
w
ww
.acu
rlit
e.co
m
sale
s@ac
urlit
e.co
m
NO
V 3
0, 2
017
D8
6" = 1' - 0"