ACUIX™ ES PTZ Dome Quick Installation Guide SW2: Baud Rate and Parity SW4: Dome Address OFF (default) Not terminated ON Terminated in 120 Ohms Switch SW5 RS485 Termination SW5: RS485 Termination Typical SW2 and SW3 Switch Settings (Protocol, Baud and Parity) DIP Switch Close Up Scan Assembly Mainboard Switches SW2 to SW5 Parity SW2/5 SW2/6 None (PAL default) OFF OFF Even (NTSC default) ON OFF Odd OFF ON SW5 is located on the opposite side from the DIP switches. SW2 - Baud/Parity SW3 - Protocol SW4 - Address SW5 on other side Pre-installation Cautions All types of installations must be performed by qualified technical personnel and must be in accordance with all national and local mechanical and electrical codes. Ensure the mounting surface and installation hardware can hold the combined weight of the scan assembly, housing, lower dome and mount. Any wall or ceiling mounting of the product should follow the manufacturer’s instructions for the mount used and use best installation practice appropriate for the structure and material the mount is being attached to. To prevent damage to the mainboard, follow standard industry precautions for electrostatic discharge sensitive devices. Cable preparation should be completed prior to the installation. Each dome requires 24V AC at 1 A or 12V DC at 1.5 A. The power supply should be located as close to the dome as possible for service and electrical isolation purposes. How to Use this Guide 1. Follow the instructions on pages 2 or 3 for your specific installation type (indoor pendant, surface mount or in-ceiling). 2. Refer to pages 1 and 4 for switch, power and wiring information, which is the same for all installations. 3. Numbered steps have cross references to the insets labeled A through F. These instructions are only a basic guide. Refer to the ACUIX ES Installation and Configuration Guide for detailed safety and installa- tion information not included here and to configure the domes. Not all models or options are shown and the step order may vary. A * NTSC default settings: MAXPRO-mode protocol, 9600 baud, even parity. ** PAL default settings: VCL 485 protocol, 9600 baud, no parity. 1 ON SW5 RS485 Termination 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 IntelliBus™ 38400 baud, no parity OFF ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON MAXPRO* 9600 baud, even parity* OFF OFF ON OFF ON OFF OFF OFF OFF ON OFF OFF OFF OFF OFF ON VCL - RS485** 9600 baud, no parity** OFF OFF ON OFF OFF OFF OFF OFF ON ON OFF OFF OFF OFF OFF ON VCL UTC 9600 baud, no parity OFF OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF ON Diamond 9600 baud, even parity OFF OFF ON OFF ON OFF OFF OFF ON OFF OFF OFF OFF OFF OFF ON Pelco P 4800 baud, no parity (default for P-type control) ON ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF OFF OFF OFF ON Pelco D 2400 baud, no parity (default for D-type control) OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON OFF OFF OFF OFF ON Protocol Baud and Parity Description SW2 - Baud and Parity Settings SW3 – Protocol Setting Baud Rate SW2/1 SW2/2 SW2/3 SW2/4 600 OFF OFF OFF OFF 1200 ON OFF OFF OFF 2400 OFF ON OFF OFF 4800 ON ON OFF OFF 9600 (default) OFF OFF ON OFF 19200 ON OFF ON OFF 38400 OFF ON ON OFF 57600 ON ON ON OFF 115200 OFF OFF OFF ON For most installations, leave SW3-8 ON, otherwise users can make changes from the OSD menu. NTSC or PAL settings are based on camera model. Binary Value/Dome Address SW4/1 SW4/2 SW4/3 SW4/4 SW4/5 SW4/6 SW4/7 SW4/8 1 (default) ON OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF 5 ON OFF ON OFF OFF OFF OFF OFF See the ACUIX ES Installation and Configuration Guide for a more extensive table.

Transcript of ACUIX™ ES PTZ Dome Quick Installation Guide · PDF fileACUIX™ ES PTZ Dome Quick...

ACUIX™ ES PTZ Dome Quick Installation Guide

SW2: Baud Rate and Parity

SW4: Dome Address

OFF (default) Not terminated

ON Terminated in 120 Ohms

Switch SW5 RS485 Termination

SW5: RS485 Termination

Typical SW2 and SW3 Switch Settings (Protocol, Baud and Parity)

DIP Switch Close Up

Scan Assembly Mainboard Switches SW2 to SW5

Parity SW2/5 SW2/6

None (PAL default) OFF OFF

Even (NTSC default) ON OFF

Odd OFF ON

SW5 is located on the opposite side from the DIP switches.

SW2 - Baud/Parity

SW3 - ProtocolSW4 - Address

SW5 on other side

Pre-installation CautionsAll types of installations must be performed by qualified technical personnel and must be in accordance with all national and local mechanical and electrical codes.

Ensure the mounting surface and installation hardware can hold the combined weight of the scan assembly, housing, lower dome and mount. Any wall or ceiling mounting of the product should follow the manufacturer’s instructions for the mount used and use best installation practice appropriate for the structure and material the mount is being attached to.

To prevent damage to the mainboard, follow standard industry precautions for electrostatic discharge sensitive devices.

Cable preparation should be completed prior to the installation. Each dome requires 24V AC at 1 A or 12V DC at 1.5 A. The power supply should be located as close to the dome as possible for service and electrical isolation purposes.

How to Use this Guide1. Follow the instructions on pages 2 or 3 for your specific installation type (indoor pendant, surface mount or in-ceiling).2. Refer to pages 1 and 4 for switch, power and wiring information, which is the same for all installations.3. Numbered steps have cross references to the insets labeled A through F.

These instructions are only a basic guide. Refer to the ACUIX ES Installation and Configuration Guide for detailed safety and installa-tion information not included here and to configure the domes. Not all models or options are shown and the step order may vary.

A

* NTSC default settings: MAXPRO-mode protocol, 9600 baud, even parity.** PAL default settings: VCL 485 protocol, 9600 baud, no parity.

1

ON SW5 RS485 Termination

1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8IntelliBus™ 38400 baud, no parity OFF ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON

MAXPRO* 9600 baud, even parity* OFF OFF ON OFF ON OFF OFF OFF OFF ON OFF OFF OFF OFF OFF ON

VCL - RS485** 9600 baud, no parity** OFF OFF ON OFF OFF OFF OFF OFF ON ON OFF OFF OFF OFF OFF ON

VCL UTC 9600 baud, no parity OFF OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF ON

Diamond 9600 baud, even parity OFF OFF ON OFF ON OFF OFF OFF ON OFF OFF OFF OFF OFF OFF ON

Pelco P 4800 baud, no parity (default for P-type control)

ON ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF OFF OFF OFF ON

Pelco D 2400 baud, no parity (default for D-type control)

OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON OFF OFF OFF OFF ON

ProtocolBaud and Parity

DescriptionSW2 - Baud and Parity Settings SW3 – Protocol Setting

Baud Rate SW2/1 SW2/2 SW2/3 SW2/4

600 OFF OFF OFF OFF

1200 ON OFF OFF OFF

2400 OFF ON OFF OFF

4800 ON ON OFF OFF

9600(default)

OFF OFF ON OFF

19200 ON OFF ON OFF

38400 OFF ON ON OFF

57600 ON ON ON OFF

115200 OFF OFF OFF ON

For most installations, leave SW3-8 ON, otherwise users can make changes from the OSD menu.

NTSC or PAL settings are based on camera model.

Binary Value/Dome Address SW4/1 SW4/2 SW4/3 SW4/4 SW4/5 SW4/6 SW4/7 SW4/8

1 (default)ON OFF OFF OFF OFF OFF OFF OFF

2OFF ON OFF OFF OFF OFF OFF OFF

3ON ON OFF OFF OFF OFF OFF OFF

4OFF OFF ON OFF OFF OFF OFF OFF

5ON OFF ON OFF OFF OFF OFF OFF

See the ACUIX ES Installation and Configuration Guide for a more extensive table.

Refer to inset

All ACUIX ES pendant/surface mount shipments include both the skirt and top cap. Use the part appropriate to the type of installation.

Installing the Indoor Pendant or Surface Mount Dome

Skirt

Wiring access hole

Surface MountB

Ceiling mount (HDCM1)

Corner adapter (HDXCMA1)

Pole mount adapter (HDXPMA1)

Lower dome

Cover

Top cap

Wall mount (HDVWM1)

Pendant Mounts and Adapters

Indoor Pendant

C

Top Cap

Skirt

Scan Assembly*

Cover

Lower Dome

* Surface mount with skirt shown

Pendant and Surface Components

2

B

C

A

F

B

C

F

Video Switch, Plugs and BNC Connector

4

3

5

6

Indoor Pendant (Using the Top Cap)Drill the mount holes into the ceiling or wall. Before securing the mount to the surface, pull the field wiring through the mount. Make sure the wires extend at least 12 inches (305 mm) past the end of the ceiling or wall mount threaded pipe.

Pull the wiring from the mount and through the top cap. Cut the cable length to 6 inches (152 mm). Screw the top cap into the wall or ceiling threaded pipe. For the wall mount, use the supplied conduit.

Surface Mount (Using the Skirt)Pull the wires through the skirt wiring access hole and mount the skirt on the ceiling.

Finish pulling the field wiring through the skirt. Cut the cable length to 6 inches (152 mm).

Both Installations (Pendant and Surface)

Set the switches on the scan assembly mainboard (SW2, SW3, SW4 and SW5) and the outside of the scan assembly (SW1). Attach the lanyard from the top cap or skirt to the scan assembly.

Remove the plugs from the scan assembly, screw the wiring (power, RS485 data, contacts) into the holes then put the plugs back. If required, connect the BNC (for coax).

Secure the scan assembly to the top cap or skirt using 8-32 0.375 Pan Phil machine screws.

Align the 3 hooks on the cover with the 3 holes on the inside of the top cap or skirt. Rotate the cover until it is secure inside the top cap or skirt.

Align the 2 holes on the lower dome with the 2 screw holes on either side of the scan assembly. Secure the lower dome to the scan assembly.

1

2

1

2

7

Pendant installed with a wall mount

C

Installing the In-Ceiling Dome into a Dropped or Hard Ceiling

Refer to inset

Lower Dome

Trim Ring

Scan Assembly and Housing

Lower dome

Cable can

In-ceiling

Turning screws and wing tabs

Trim ring

DWiring access hole and clamp

Cable Can

Components

Video Switch, Plugs and BNC Connector

Hard CeilingUsing the mounting template, cut a 7 5/8” (194 mm) diameter ceiling hole.

If the ceiling is drywall or plaster, seal the perimeter of the hole with tape or plastic channel to prevent debris from contaminating the scan assembly.

Dropped (False) CeilingRemove the ceiling panel and place the ceiling tile on the dropped ceiling plate (part number 517082-7130). Trim the ceiling tile and press it into the plate.

Using the mounting template, cut a 7 5/8” (194 mm) diameter ceiling hole flush with the hole in the center of the plate.

Both Installations (Hard or Dropped Ceiling)

If required, attach a safety cable from a building support structure to the safety cable bracket. Use a 3/32” (2.4 mm) plastic coated aircraft cable with looping sleeve.

Unsnap/remove the cable can and set the switches on the scan assembly mainboard (SW2, SW3, SW4 and SW5) and outside of the scan assembly housing (SW1).

Remove the plugs from the scan assembly housing, screw the wiring (power, RS485 data, contacts) into the holes then put the plugs back. If required, connect the BNC (for coax).

Pull all the wiring from the plugs through the cable can hole. Ensure the wiring extends at least 1 foot (0.3 m) past the end of the hole and cut the cable to 6 inches (152 mm). Tighten the wire clamp to hold the wires in place.

Attach the cable can to the top of the housing. Insert the cable can and housing through the hole in the ceiling.

Position the wing tabs. Make the space between the wing tabs and the housing flange greater than the thickness of the ceiling and stagger the wing tabs to different heights. Position flat and turn clockwise to rotate the tabs out and tighten against the ceiling.

Insert the trim ring into the housing and rotate it to secure. Secure the lower dome to the housing with the screws.

1

2

3

1

4

2

5

6

7

8

9

Safety Cable Bracket

Wing Tab

Safety Cable Bracket and Wing Tabs

Turning Screw

Stagger the Wing Tabs

E

3

A

F

E

D

E

D

D

F

Honeywell Systems Group2700 Blankenbaker Pkwy, Suite 150Louisville, KY 402991.800.796.CCTV (2288)

www.honeywellvideo.com

800-01116 Rev BOctober 2008© 2008 Honeywell International Inc.

Video, Data, Power, Contact and UTP CablingType Recommended Cable Maximum Distance

VideoCoaxial Cable - RG59/U

Connector - BNC crimp on for RG59/U1000 feet (305 m)

DataOne shielded twisted pair, RS485 cable,

can also be Cat5 or better4000 feet (1219 m)

Power 18 AWG 2-conductor See gauge chart for each unit

Contact 20 gauge unshielded twisted pair 10,000 feet (3048 m)

Unshielded Twisted Pair (UTP) Video

CAT5 or better; 1 twisted pair for data, 1 twisted pair for video

750 feet (230 m)

PIN Description

1 24V AC input A or 12V DC (+) or (-)

2 ESD (electrostatic discharge) grounding

3 24V AC input B or 12V DC (+) or (-)

4 RS485 data (-) communication signal

5 RS485 data (+) communication signal

PIN Description

1 Contact input 1

2 Contact input common

3 Contact input 2

PIN Description

1 UTP + signal

2 UTP - signal

3 Contact input 3

4 Contact input 4

5 Contact input 5

6 Contact input 6

7 Contact input 7

8 Contact input 8

9 Contact input common

Wire Gauge for Maximum Distance to Dome

P1 Power, Data and RS485 (5-pin Plug)

P2 Contact (3-pin Plug)P3 Contact (9-pin Plug)Power Supply

Wire Gauge (AWG)

mm2 Feet Meters

24 0.5 35 10

Doubled 24 0.5 x 2 70 20

18 1 145 45

16 1.5 230 70

14 2.5 360 110

24 0.5 15 5

Doubled 24 0.5 x 2 35 10

18 1 70 20

16 1.5 115 35

14 2.5 180 55

24V AC

12V DC

Wiring and Power Information

Power Supplies

SW1 Video

Video Switch SW1, Plugs and BNC Connector

F

Each dome requires a 24V AC at 1 A or 12V DC at 1.5A ± 15% power source when measured at the dome.

To maintain this at each dome, the proper wire size for the distance and the number of domes must be determined.

ON

OFF

P3

P2

Contact Wiring Plugs

Power and Data Wiring Plug

SW1 Video

PlugsP1

BNC Connector

A good earth ground must be connected at the 5-pin connector, P1, pin 2. Surge, ESD and EMC performance will be compromised if the unit is not connected to a good earth ground.

OFF (default) COAX video enabled

ON UTP video enabled

Switch SW1 Video Selection

Pendant/surface shown. In-ceiling is similar.

Application Specification

Internal - 1 per ACUIX ES24V AC 1 amp x 1, or 12V DC 1.5 amp x 1