ACTIVE CHILLED BEAMS ACB20...

5
E U R O P E DADANCO Active Chilled Beams 1 ACB20 (2-way) ACTIVE CHILLED BEAMS

Transcript of ACTIVE CHILLED BEAMS ACB20...

Page 1: ACTIVE CHILLED BEAMS ACB20 (2-way)dadancoeu.com/images/downloads/153983_Dadanco_ACB20_Leaflet_… · active chilled beam avoids all the concerns with using inferior inclined coil

E U R O P EDADANCO

Active Chilled Beams

1

ACB20 (2-way)

ACTIVE CHILLED BEAMS

Page 2: ACTIVE CHILLED BEAMS ACB20 (2-way)dadancoeu.com/images/downloads/153983_Dadanco_ACB20_Leaflet_… · active chilled beam avoids all the concerns with using inferior inclined coil

2

The new low height twin vertical coil ACB20 (2-way)

active chilled beam avoids all the concerns with using

inferior inclined coil beams, without exceeding a height

of 286mm. The new ACB20 utilizes DADANCO’s unique

nozzle and unit fluid dynamics technology.

This patented technology provides very high air

entrainment ratios at low pressure drops and provides

the major benefit of superior performance delivered at

the lowest noise levels.

Typical Performance Data

Primary airflow

8 to 80 L/s @ Static pressure range of 50 - 175 Pa

Secondary Chilled Water

0.03 - 0.15 L/s

Performance Range

500 - 2,000 W

Typical Product Data

Length - 600 to 3000mm.

Width - Typically to suit T-Bars at 600mm centers, with fat and

tegular edge border styles as standard.

Appearance - Traditional perforated face.

Discharge - 2 way.

Coil - Vertical 2 or 4 pipe option with drip trays and sweat

or NPT fittings.

Primary air connection - Side or top entry as standard.

DADANCO Active Chilled Beams have been tested both

in-house and independently at ETL Laboratories.

DADANCO Technology

Conventional Nozzles DADANCO Nozzles

E U R O P EDADANCO

Page 3: ACTIVE CHILLED BEAMS ACB20 (2-way)dadancoeu.com/images/downloads/153983_Dadanco_ACB20_Leaflet_… · active chilled beam avoids all the concerns with using inferior inclined coil

3

‘Even with a reduced height there is no loss of performance, from the new ACB20, over its predecessor.’

ATC

COIL

COILRF

Secondary Heat Exchangers

Cross-Section of ACB20 Active Chilled Beam

Primary Air Plenum

Supply Air Grille (x2) Return Air

Grille

Condensate Safety Trays with Drains

ACB20 units icorporate 2 secondary water heat exchangers. Secondary heat exchangers must be field connected in a parallelarrangement with control and balancing valves as specified in themechanical specification for the project.

Connection must be parallel to ensure secondary air coolingperformance as specified will be delivered by each unit.

Do not connect secondary heat exchangers in series. Secondarycooling performance will be adversely affected if system designentering secondary water is not delivered equally to both heatexchangers.

Product Details ACB20

Secondary water connections

E U R O P EDADANCO

Page 4: ACTIVE CHILLED BEAMS ACB20 (2-way)dadancoeu.com/images/downloads/153983_Dadanco_ACB20_Leaflet_… · active chilled beam avoids all the concerns with using inferior inclined coil

AIR

INL

ET

CO

NN

EC

TIO

N(S

EE

TA

BLE

3 F

OR

D

IME

NS

ION

OP

TIO

NS

)

12 '' C

OIL

CO

NN

EC

TIO

N(S

EE

TA

BLE

2 F

OR

A

VA

ILA

BLE

OP

TIO

NS

)

No

te: W

hile

eve

ry effo

rt is ma

de

to e

nsu

re th

e d

eta

ils c

on

tain

ed

in th

is p

ub

licatio

n a

re c

urre

nt a

nd

up

-to-d

ate

, in th

e in

tere

st o

f ong

oin

g p

rod

uct d

eve

lop

men

t DA

DA

NC

O E

UR

OP

E re

se

rve

s th

e rig

ht to

alte

r the

sam

e w

itho

ut n

otice

Draw

1

MA

TERIA

L:

A4

SHEET 1 O

F 1S

CA

LE:

TITLE:

UN

LESS

NO

TED

OTH

ER

WIS

EA

LL DIM

ENS

ION

IN m

m

AN

GU

LAR

TOL: 1.0°

LINE

AR

TOL:±1.50m

m

DA

TE

AC

B 20/21(2WA

Y)

AC

B 20/21 SUB

MITTAL D

RA

WIN

G

22. 3. 2016.

DAD

AN

CO

EU

RO

PE

PR

OJE

CT N

AM

E

DES

IGN

:

REV

IEW:

CE

RTIFE

D:

TA

BL

E 2

AV

AIL

AB

LE

OP

TIO

NS

Ø1/2

'' O.D

.SW

T C

ON

NE

CT

ION

Ø1/2

'' FE

MA

LE

NP

T C

ON

NE

CT

ION

Ø1/2

'' MA

LE

NP

T C

ON

NE

CT

ION

AC

B21

2

AC

B2

14

AC

B2

16

AC

B2

18

AC

B2

11

CO

DE

LE

NG

TH

WID

TH

RE

F L

RE

F W

59

5

11

95

17

95

23

95

29

95

59

54

38

103

8

163

8

22

38

28

38

56

4

TA

BL

E 1

59

5

59

5

59

5

59

5

56

4

56

4

56

4

56

4

TA

BL

E 3

RE

F.

DIA

ME

TE

R

80

100

125

150

160

200

RO

UN

D

RO

UN

D

RO

UN

D

RO

UN

D

RO

UN

D

ELIP

SE

Page 5: ACTIVE CHILLED BEAMS ACB20 (2-way)dadancoeu.com/images/downloads/153983_Dadanco_ACB20_Leaflet_… · active chilled beam avoids all the concerns with using inferior inclined coil

Government, Institutional & Defense Buildings

Hospital & Healthcare………………

Schools & Universities……………

Commercial Offices……………

Green Renovations………

Laboratories………

Hotels……

Bulevar Mihajla Pupina 16V 11070 Novi Beograd Republic of Serbia Tel: +381 11 367 57 64

www.dadancoeu.com

[email protected]

Tel: +381 11 367 57 82

E U R O P E