ACS 500S1 2000VA - EM TestACS 500 Output Power 6000VA Input Power 3 x 400V 32A Output Current 50 Hz...
Transcript of ACS 500S1 2000VA - EM TestACS 500 Output Power 6000VA Input Power 3 x 400V 32A Output Current 50 Hz...
ACS 500S1 2000VA AC Source
for Harmonics & Flicker testing
ACS 500S1 is a single phase AC source, specially designed for testing
Harmonics and Flicker. It provides a perfect sinusoidal and stable
voltage, adjustable both in frequency and amplitude.
The specifications are in accordance with EN / IEC 61000-3-2 / -3.
and JIS C 610000-3-2
S p e c i f i c a t i o n
• EN/IEC 61000-3-2
• JIS C 61000-3-2
• EN/IEC 61000-3-3
e m c t e s t e q u i p m e n t
Specifications
EM TEST AG Tel: +41 (0)61 717 91 91Sternenhofstr. 15 Fax: +41 (0)61 717 91 99 data sheet ACS 500S1 V200.docCH-4153 Reinach email: [email protected] 10.12.2007Switzerland URL http://www.emtest.com Page 2/3
The output voltage is guaranteed to be perfectly sinusoidal, with a low distortion (THD) less than 0.1% regardless of the load. The value ofoutput voltage is kept perfectly stable within 0.1% independent of the load. ACS 500S1 is capable to keep the voltage stable even with variableloads, as for example pulsating loads.
ACS 500S1 allows the setting of the output frequency between 10Hz and 80Hz. The output frequency can be adjusted continuously within thespecified frequency range with a stability of 0.01%.
Block diagram
The ACS 500S1 is controlled from the DPA 500 by a RS 232 link.
The DPA 500 measures the voltage and current for harmonic and flickeranalyzing. A built in lumped flicker impedance can be bypassed for theharmonic measurement.
The system is operated from the computer with the windows softwareISMDPA.
System for Harmonic and Flicker measurement with AC sourceACS 500S1 and analyzer DPA 500
OutputVoltage Range 0 to 300VVoltage Resolution 0.025% (12 bit)Output Frequency 10Hz to 80 HzFrequency Resolution 0.02 HzFrequency accuracy, stability 100ppmOutput Power 2000VAOutput connector Safety banana plug
Output Current maximum 50 Hz 60 Hz
Continuous 7.7 A 8.0 ARMS max. 3s 15.1 A 15.4 ARepetitive. peak 60 A 60 A
RegulationVoltage Sense internal or
external 4 wiresTotal harmonic distortion < 0.1%Output voltage stability < 0.1%Output voltage accuracy < 0.5%Max. compensatable drop on wires 5% f.s.Protection Overcurrent
OvertemperatureOvervoltageUntervoltage
InputSupply voltage 230V L N PE Input current 16ALine frequency 50Hz / 60HzFuse 16A internalConnector 16A
Specifications
EM TEST AG Tel: +41 (0)61 717 91 91Sternenhofstr. 15 Fax: +41 (0)61 717 91 99 data sheet ACS 500S1 V200.docCH-4153 Reinach email: [email protected] 10.12.2007Switzerland URL http://www.emtest.com Page 3/3
Overload curve (rms)
Overload curve ( resistive )
Ambient conditionsTemperature operating 0° to 35°Humidity 80% non condensing
ControlInterface RS 232 9pole Sub D
DimensionsHousing 19”, 6HUWeight 23 kgACS 500 S1 287 x 449 x 500
Rearside
Rear side view ACS 500S1
OptionsDPA 500 Harmonic and Flicker meter 16ARack 25 HU with Safety Circuit
Additional Model ConfigurationACS 500 Output Power 6000VAInput Power 3 x 400V 32A
Output Current 50 Hz 60 HzContinuous 24.0 A 24.9 APeak ( max. 3s ) 47.0 A 47.9 A