Acme Dry Type Distribution Transformer TF217437S to TF252797S

3
Subcategory : Phase : Frequency: kVA: K rating: Pri. configuration: Sec. configuration: Reverse connectable: Winding material: Electrostatic shielded: Temperature rise: Insulation system: Enclosure rating: Enclosure material: Construction style: Mounting type: Connection type: Cooling: Agency approvals: Sound level: Warranty: Corporate Headquarters: TEMCo – Tower Electric Motor Company 41474 Christy Street Fremont, CA 94538 Inside USA (877) 474-8209 International (510) 490-2187 Fax (510) 490-1507 TF217437S to TF252797S Isolation Single 50/60 Hz 1 to 25 kVA 1 Two winding Two winding Aluminum No 115 Deg C 180 Deg C NEMA 3R Steel Enclosed - Encapsulated Core & Coil Wall Wire Leads Air/dry UL Listed, CSA Approved, CE Marked, meets NEMA, ANSI and OSHA standards. Below NEMA standards. 10 years Acme Dry Type Distribution Transformer www.temcoindustrialpower.com Yes 190/200/208/220 x 380/400/416/440 V Primary - 120/240 V Secondary

Transcript of Acme Dry Type Distribution Transformer TF217437S to TF252797S

Page 1: Acme Dry Type Distribution Transformer TF217437S to TF252797S

Subcategory :

Phase :

Frequency:

kVA:

K rating:

Pri. configuration:

Sec. configuration:

Reverse connectable:

Winding material:

Electrostatic shielded:

Temperature rise:

Insulation system:

Enclosure rating:

Enclosure material:

Construction style:

Mounting type:

Connection type:

Cooling:

Agency approvals:

Sound level:

Warranty:

Corporate Headquarters: TEMCo – Tower Electric Motor Company 41474 Christy Street Fremont, CA 94538 Inside USA (877) 474-8209 International (510) 490-2187 Fax (510) 490-1507

TF217437S to TF252797S

Isolation

Single

50/60 Hz

1 to 25 kVA

1

Two winding

Two winding

Aluminum

No

115 Deg C

180 Deg C

NEMA 3R

Steel

Enclosed - Encapsulated Core & Coil

Wall

Wire Leads

Air/dry

UL Listed, CSA Approved, CE Marked,meets NEMA, ANSI and OSHA standards.

Below NEMA standards.

10 years

Acme Dry Type Distribution Transformer

www.temcoindustrialpower.com

Yes

190/200/208/220 x 380/400/416/440 V Primary - 120/240 V Secondary

Page 2: Acme Dry Type Distribution Transformer TF217437S to TF252797S

Corporate Headquarters: TEMCo – Tower Electric Motor Company 41474 Christy Street Fremont, CA 94538 International (510) 490-2187 Fax (510) 490-1507

www.temcoindustrialpower.comInside USA (877) 474-8209

Acme Dry Type Distribution Transformer

Dimensions (in inches)

TF217437S to TF252797S

Part # KVA Height Width Depth Weight (lbs) DiagramTF217437S 1 10.5 5.5 5.13 24 BTF217439S 2 13 5.5 5.13 38 BTF249873S 3 11.5 10.31 7.13 55 CTF252520S 5 14.38 10.31 7.13 75 CTF2-52794S 7.5 15.19 13.5 10.84 115 DTF252795S 10 15.19 13.5 10.84 125 DTF252796S 15 16.94 14.12 11.59 170 DTF252797S 25 18.44 16.13 13.34 300 D

Design B Design C Design D

D

H

W

D

H

W

D

H

W

Page 3: Acme Dry Type Distribution Transformer TF217437S to TF252797S

Corporate Headquarters: TEMCo – Tower Electric Motor Company 41474 Christy Street Fremont, CA 94538 International (510) 490-2187 Fax (510) 490-1507

www.temcoindustrialpower.comInside USA (877) 474-8209

Acme Dry Type Distribution Transformer TF217437S to TF252797S

EXPORT MODEL PRIMARY: 190-220 x 380-440 SECONDARY: 120/240

X4 X1

H5

H3

H1

X2 X3

H2 H4

H6

H7 H8 H9

H10

Connect Connect Primary Primary Inter- Secondary Volts Lines To Connect Lines To

190 H1 & H7 H1 to H6 H2 to H7

200 H1 & H8 H1 to H6 H3 to H8

208 H1 & H9 H1 to H6 H4 to H9

220 H1 & H10 H1 to H6 H5 to H10 380 H1 & H7 H2 & H6 400 H1 & H8 H3 & H6 416 H1 & H9 H4 & H6 440 H1 & H10 H5 & H6Secondary Volts 240 X2 to X3 X1-X4 120/240 X2 to X3 X1-X2-X4

120 X1 to X3 X1-X4 X2 to X4

14