Accurate Experimental Charge Density Data: Tips & Tricks for...

40
Accurate Experimental Charge Density Data: Tips & Tricks for Data Collection & Processing Holger Ott [email protected] Bruker AXS/MIT Symposium 2019 February 23, 2019 February 23, 2019

Transcript of Accurate Experimental Charge Density Data: Tips & Tricks for...

Page 1: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Accurate Experimental Charge Density Data: Tips & Tricks for Data Collection & Processing

Holger Ott

[email protected]

Bruker AXS/MIT Symposium 2019

February 23, 2019

February 23, 2019

Page 2: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Overview

• Before we start

• Experiment phase

• Data processing

2 February 23, 2019

Page 3: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

February 23, 2019 3

How many people in this rooms have done charge density data collections before?

Who is doing them for less than 1 year?

Who is planning to do charge density experiments in the future?

Charge Density Experiments: Survey

Page 4: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Charge Density Experiments: Anything to Consider Before We Start?

February 23, 2019 4

• Beam okay?

• Beam through goniometer center?

• Video microscope okay? Goniometer okay?

• Correct collimator on?

• Goniometer head properly fixed? Worn out?

• Magnet tight? (for pin mounting)

• Low-T okay? (no ice, no shadow, centered)

• How to mount the sample?

Page 5: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

February 23, 2019 5

We should make sure that the diffractometer is in good conditions before we start!

What to check:

• Primary beam intensity still okay?

• Comparing test shots from installation under \frames\alignment

• Run ylid test crystal with same strategy as in “cust” project

• Beam passing through goniometer center?

• Half beam alignment procedure (don’t use steel ball shadow)

• Collimator fine?

• Not clipping the beam (IµS ~3 % counts; removed air scatter)

• No diffuse background around beam stop

• Beam stop good?

• Right size (low res. reflections important; now long axis beam stop available)

• Properly centered (important for beam stop masking)

• No back scattering at high resolution!

Checking the Instrument

Page 6: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

February 23, 2019 6

When the beam stop “shoots back”!

Checking the Instrument

High-res. Low-res.

Page 7: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

February 23, 2019 7

• Corrections: 2θ zero adjusted?

• Beam center, detector distance, detector rotations set?

• Vertical beam tilt & omega zero okay?

• Check the „unconstraint global unit cell“ angles of the ylid crystal.

• They should be well within 0.03 deg. Otherwise, modify the tilt angle in Determine Unit Cell - Unit Cells - Edit and recheck. Apply corrections again if needed

Please note: Don’t modify the Chi angle on the goniometers!

• Low temperature nozzle perfectly centered above crystal?

• Goniometer head tight (check carefully during crystal centering)

• Magnet fixed?

• Attenuator stored (used during beam check)/ unchecked BIS option?

Checking the Instrument

Page 8: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Low-Temperature Device

Needs to be:

• Stable

• Operating ice-free for a long time (1 - 14 days):

• Slim brass/copper pin (I prefer ALS style pins)

• Adjust shield stream to achieve a laminar flow

• Comply with service intervals of shield stream compressor

• Magic angle of a FIXED-CHI beneficial for minimal turbulences; Chi angle can be limited on a KAPPA with coolerlowkappa and coolerhighkappa commands in the bn-config.py file

• Sometimes better to switch cabinet fans off (DIFFRAC.TOOLS - Enclosure)

• Reach the lowest possible temperature (deconvolute ED from atomic movement; avoid thermal diffuse scattering, TDS)

8 February 23, 2019

Page 9: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Low-Temperature Device

• Should not shade detector area, but sometimes this is not possible

• In the past one had to rely on the active mask creation (do not use with PHOTON detectors), paint a custom mask file or use the outlier masking in SADABS

• Now, you can add the Cryostream 700/800, Helix, or Kryoflex II to the Goniometer Viewer

• The current cryo nozzle distance can be updated under Instrument - Update Cryo Nozzle Distance…

9 February 23, 2019

Page 10: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Mask File

• The name_xa_0X_0001.sfrm file contains the cryo nozzle shadow as an integration mask

• The 2019.1 version can make use of the mask file to improve the strategy optimization.

• The options are (cummulative): “Not used”: only beam catcher is considered “Basic”: bad pixels are considered “Positional”: beam stop holder and cryo nozzle shadow

10 February 23, 2019

Page 11: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Mask File

• Inspection of missing reflections with the 3D strategy result viewer

• Additional sphere shows beamstop shaded area

• Number of affected reflections are listed now

11 February 23, 2019

Page 12: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

12 February 23, 2019

The CRYSTAL

• Find the perfect imperfect crystal! i.e. no splitting, twinning, (localized diffuse scattering) sufficient mosaicity to minimize extinction effects

• Try to match the crystal size with the beam. Scaling can compensate for crystal volume effects

• Shape ideally isotropic

The Driver

• Take your time for the preparation and the design of the experiment

• Make sure that you got enough beam time

Ready to Go?!

Page 13: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

13 February 23, 2019

Crystal Size

• Regular fine-focus sealed tube beams can be tuned in size with the collimators. Don’t use a too large collimator for a smaller crystal, as you increase the diffuse background and affect the I/σ(I).

• Modern microfocus (rotating anode or sealed-tube) sources provide fine Gaussian-type beam profiles around 100 micron in FWHM.

• Ideally, the crystal should fully “bath” in beam. However, this is not always possible for charge density research, because the diffraction power of a 100 micron crystal may not be sufficient to achieve the required resolution.

• Depending on the content of the crystal a larger crystal size may also work. The weaker absorbing the sample, the larger the size can be. 300 to 400 microns normally work for organic samples, heavier absorbing samples should be smaller

Ready to Go?!

Page 14: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Sample Mount

Requirements:

• Stable crystal position (i.e. no nylon loops, thin glass fibers)

• Minimal interference with cold stream

• As little oil or other crystal fixation means as possible

The diffuse background signal is limiting the crude I/σ(I) for photon

counting detectors

• Crystal should preferable not be aligned along the phi axis

14 February 23, 2019

Page 15: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Starting the Experiment

February 23, 2019 15

GCP (Good Crystallography Practice): Crystal Centering

1. Mount sample and center the crystal properly

2. Start Fast Scan (even 370 deg phi scan, ≤ 0.5 deg steps)

3. Determine unit cell

4. Calculate strategy

5. Re-center crystal now that the sample holder/gonio-head is cold (in tricky cases consult crystal translations in Determine Unit Cell or use X-ray centering with the AGH)

6. Start data collection

Page 16: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Starting the Experiment

February 23, 2019 16

GCP: Basics

Never leave the instrument before you see the first image! Be aware of:

• Dummy beamstops

• Bent beamstop (mechanical stress or pushed by low-T nozzle)

• Removed beamstop on single source instruments

• Cryo mounting

• Desperate approach to get low resolution reflections

Always check the goniometer viewer when you take over the diffractometer!

Page 17: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

The Unit Cell Determination

February 23, 2019 17

GCP: Unit Cell determination

1. Determine Unit Cell from pre-scans

2. Start data collection (optimized or canned)

3. Re-determine unit cell from main runs

Pre-Scan Main run(s)

Page 18: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

The Experiment Parameters

February 23, 2019 18

• Detector distance - Short is not always the best

Consider:

• Reflection overlap

• Goniometer limits

• Diffuse scattering signals drop off with 1/r2

• Oblique/incident angle correction

Standard APEX II/PHOTON 100/PHOTON II/PHOTON III C have ~92 % phosphor efficiency for Mo and ~68 % for Ag radiation.

The more acute the reflections hit the detector, the more needs the intensity of the reflections at the edge of the detector be corrected (reduced)

Page 19: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

The Experiment Parameters

February 23, 2019 19

• Resolution

• IUCr/Acta requirements: 0.464 Å (100 deg in 2θ for Mo)

• There should be at least a data/parameter ratio after the multipole refinement of 10

• Exposure time

• The software can help with the “Expected resolution” table or the new “Estimate Exposure Time” feature.

• Make use of the available time! Increase exposure time or redundancy?

• Redundancy

• At least 30 for low resolution data in correct point group

• More than 10 for the highest resolution shell

Page 20: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

The Experiment Parameters

February 23, 2019 20

• Chi limitation for KAPPA goniometers?

• Coolerlowkappa = 40.0 Coolerhighkappa = 100.0

• This reduced “ice-beard” formation and turbulences

• Never go too low with chi, otherwise your crystal height will change! e.g. 50 microns at Chi = 10 deg

• Take off Cu beamstop on VENTURE dual wavelength systems

Page 21: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

The Experiment Parameters

February 23, 2019 21

• 3λ Filter?!

• First described: Storm, A. B., Michaelsen, C., Oehr, A. & Hoffmann, C. (2004). Proc. SPIE, 5537, 177–181.

• I recommend to use it for all mirror sources

• 100 mu Al foil works

R. Herbst-Irmer, D. Stalke, Acta Cryst., 2017. B73, 531–543

Page 22: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Charge Density Strategy Optimization

22 February 23, 2019

2θ Detector Settings

• Large 10 (20) x 14 cm active detector area allows to collect high resolution data in one or just a few 2θ positions

• Regular strategy settings will lead only to high resolution runs (may minimize the need for data scaling)

Field of view

@ 6 cm [deg] PHOTON II/III 14 APEX II

Equatorially 80 54

Vertically 98 54

Diagonally 110 71

Page 23: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Charge Density Strategy Optimization

23 February 23, 2019

I recommend the following procedure:

1. Use fine slicing for charge density (0.25 to 0.5 deg steps; ultra fine slicing not required)

2. Optimize a low resolution data set using the correct point group with 2θ close to 0 deg (depending on wavelength and detector distance 0.65 to 0.80 Å) and add runs to experiment list.

3. Run strategy optimizer with correct point group from scratch (restart) asking for the desired resolution and append runs

4. Add a few medium resolution runs to the experiment

5. Import all runs to the optimizer, check redundancy, and extend strategy for a lower symmetry

6. Add 1 to 3 fast scans with different exposure times, but similar scan width

7. New for PHOTON III detectors: Mix sensitive and dynamic mode runs (for weakly diffracting samples more sensitive mode runs at high 2θ)

Page 24: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Charge Density Strategy Optimization

24 February 23, 2019

Dynamic Range Considerations

• Pixels may get saturated when too many X-rays are collected

• Reflections that contain saturated pixels are automatically rejected during the integration step and may affect data completeness

• Data collection strategy should include a set of “Fast Scans”

• These are quick low 2θ runs in which no pixel gets saturated. This is achieved by reducing the exposure time, (increasing the scan width), or attenuating the primary beam

• Fast scans are treated separately during scaling

• CCD charge density results are also positively affected by using quick scans rather than an overflow protection (“retake if topped” option)

Page 25: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Charge Density Strategy Optimization

25 February 23, 2019

New features in the Run Experiment plugin

Different detector modes and attenuation settings are now available in the experiment table:

• PHOTON III: Dynamic (PHOTON II charge integration mode) or Sensitive mode (MIXED MODE, photon counting & charge integration)

• PHOTON 100: Shuttered or Shutterless operation

• CCDs: Automatic, uncorrelated or correlated images

• Attenuation: rotary absorber foil in/out

Page 26: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Charge Density Strategy Optimization

26 February 23, 2019

• Exposure Times

• The longer the exposure time, the less detector noise in the charge integration mode/dynamic mode (until the detector is noise free)

• Long exposure times lead to more Zinger contamination on uncorrelated images without the PHOTON III HEED feature (high energy event discrimination)

• My procedure:

1. I assign a “guessed” (you can also rely on the software suggestions) exposure to the different 2θ settings and inspect the diffraction pattern after a few images. If necessary, I try longer/shorter exposure times.

2. Modify the experiment list accordingly by hand or since 2017.3, you can also use the theta dependent exposure time function of the strategy optimizer.

3. Finally slightly alter the exposure time of the later runs by hand, so that you avoid using just a single exposure time per detector setting

Page 27: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Charge Density Strategy Optimization

27 February 23, 2019

Example: Ag Strategy

Fast Scan

Low res.

High res.

Low res.

High res. redundancy

Med res.

Low res. redundancy

Page 28: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Data Work-Up

28 February 23, 2019

Integration

• Try different background determination methods: I strongly recommend to use the “Best Plane” method (especially useful for diffuse signals)

Does that change anything? Charge Density: highest res. density dropped from 0.9 to 0.5 e/Å3

High Pressure Data: R1 dropped from 12 to 2 %

Do you like to make that mode the default?

Create a text file on C:\ called saint.ini with the following entries: [INTEGRATE] PLANEBG=1

Page 29: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Data Work-Up

29 February 23, 2019

Integration

• Check different profile fitting thresholds (default 8 I/σ(I)).

• Keep an eye on the frame queue half width. The default (7) may be too small for fine sliced data.

• High resolution cut-off for low resolution runs, if data gets weak at the corners of the detector. “Negative” side-effect of large detectors: they may be hard to fully “illuminate”.

One can set individual high resolution cut-offs for each run with the new SAINT version. For the moment being, this can be only done with the command line version by modifying the saint.ini, but we are working on a GUI implementation

Page 30: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Data Work-Up

February 23, 2019 30

Absorption and Scaling: Scale plug-in (GUI for SADABS) Generally, the most likely data processing step where people ruin their data!

• Scaling is essential for micro-focus sources!

• It ONLY works with the correct Laue (or point) group

• Some less known tweaks:

• Additional spherical absorption correction factor

• The empirical (multi-scan) absorption correction method is 2θ independent.

• In order to include the dependency, calculate the product of the absorption coefficient and crystal radius

• Does it matter? If the product > 0.5, your residual density will become more asymmetric, the ADPs will shrink and the R1 is worse!

Page 31: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Data Work-Up

February 23, 2019 31

Absorption and Scaling

• Restraint ESD for Scale Factors

• Symptoms to look for:

Page 32: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Data Work-Up

February 23, 2019 32

Absorption and Scaling

• Restraint ESD for Scale Factors

• The cure: Increase the value (default 0.005)

Page 33: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Data Work-Up

February 23, 2019 33

Absorption and Scaling

• Restraint ESD for Scale Factors

• The cure: Increase the value (default 0.005)

• Or do a numerical absorption correction (crystal must not exceed the beam)

Before After

Page 34: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Data Work-Up

34 February 23, 2019

Absorption and Scaling

• Make use of the diagnostic plots/numbers to identify outliers

• Use charge density settings for the error model part: g = 0; K = 1 Available on the command line (non-expert mode):

Page 35: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Data Work-Up

35 February 23, 2019

Absorption and Scaling

• Write XD hkl (command line or Scale plug-in)

Irons out systematic absences, averages data, and removes 0 or negative intensities and standard uncertainties

Page 36: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Data Work-Up

36 February 23, 2019

Absorption and Scaling

• λ/2 or 3λ corrections (command line or Scale plug-in)

• Fast scan treatment

• Take fast scans as regular runs if data quality is sufficient

• Use the fast scan high resolution cut-off in the Advanced Options for weaker cases (or the option on the command line)

Page 37: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Data Work-Up & (Weighting Scheme)

37 February 23, 2019

Standard Structure Quality Indicators

• XPREP statistics

• Consult regular quality criteria (APEX3, Olex2, WinGX)

• Inspect residual density like we learned yesterday

• Consider deeper validation methods (J. Henn, A. Thorn, …)

Page 38: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Data Work-Up & (Weighting Scheme)

40 February 23, 2019

Standard Structure Quality Indicators

• XPREP statistics

• Consult regular quality criteria (APEX3, Olex2, WinGX)

• Inspect residual density like we learned yesterday

• Consider deeper validation methods (J. Henn, A. Thorn, …)

XD refinement :

• Use 1/σ2 weights

• However, this often leads to large GoF values

• A way around: CAPOW: a standalone program for the calculation of optimal weighting parameters for least-squares crystallographic refinements (open access) N. T. Johnson, H. Ott, M. Probert, J. Appl. Cryst., 2018, 51, 200

Page 39: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Conclusion

41 February 23, 2019

• Accurate high quality data is the key for Quantum Crystallography

• You will only get that if you know your sample and instrument/ software well and take your time

• Diffractometer and experimental conditions need to be very good

• A smart experiment design will pay off

• Data processing has a strong influence on the final data quality

• Don’t get frustrated. The success rate will be far below 50 %

Page 40: Accurate Experimental Charge Density Data: Tips & Tricks for …web.mit.edu/x-ray/Ott_talk_2019.pdf · 2019. 3. 22. · Accurate Experimental Charge Density Data: Tips & Tricks for

Innovation with Integrity

© Copyright Bruker Corporation. All rights reserved.