Accessories that actively cooperate DRÄGER INFINITY · “Infinity ID accessories ensure that...
Transcript of Accessories that actively cooperate DRÄGER INFINITY · “Infinity ID accessories ensure that...
Accessories that actively cooperate
D-1
4582
-200
9
DRÄGER INFINITY® ID-ACCESSORIES
2 | DRÄGER INFINITY® ID-ACCESSORIES
D-1
4131
-200
9
Just a dream?
| 3
Move the patient from induction into the OR – without having to reenter ventilation parameters at the anesthesia workstation.
Change the water trap on schedule – without having to check stickers or logbooks.
Connect ventilation circuits and breathing bag – without losing control of making a proper connection.
With Infinity® ID-accessoriesfrom Dräger it simply is routine.
4 | DRÄGER INFINITY® ID-ACCESSORIES
Make your connection – and
breathe easierConnecting breathing circuits, changing water traps and replacing soda lime are some of the many tasks required on a daily basis within an intensive care unit or operating room. Even simple, routine tasks consume valuable time and require constant attention, with every single task just as important as the next. How easy is it to make an incorrect circuit connection? How easy is it to forget to change a water trap? What if the soda lime canister is not properly connected to the anesthetic machine? These mistakes can and do happen, and the consequences can be serious.
WHY NOT ENLIST SOME ACTIVE SUPPORT
FOR YOUR DAILY ROUTINE TASKS?
Infinity ID-accessories from Dräger do more than just fulfill their primary function such as ventilating a patient or measuring parameter values. Each and every Infinity ID-accessory has been designed to offer additional functionality, which – that has been demonstrated by the daily clinical routine at Zurich‘s University Hospital – can help you simplify routine tasks, streamline workflow and increase safety levels. This enables you to concentrate on the most important thing – your patients. D
-146
00-2
009
| 5
INFINITY® ID-ACCESSORIES AND THE DAILY
CLINICAL ROUTINE AT ZURICH’S UNIVERSITY
HOSPITAL
Infinity ID-accessories from Dräger have been in use at the University Hospital in Zurich since 2009. Following a successful test phase in the ENT and ophthalmology departments, doctors and caregivers have been working with ID-accessories throughout the hospital’s surgical unit. The following Infinity ID-accessories are in use on a daily basis: – various Infinity ID breathing circuits– the Infinity ID WaterLock 2 water trap – the soda lime system Infinity ID CLIC Absorber Free
ON THE ROAD TO STANDARDIZATION
WITH INFINITY® ID
Personnel at the University Hospital routinely rotate through different department operating rooms during the day. To ensure the same high standard of care in all areas, hospital management decided to standardize OR workplaces. One milestone toward standardization was Dräger Infinity ID. Doctors and caregivers alike needed little convincing, and everyone involved reported that learning to use Dräger Infinity ID-accessories on their Infinity Empowered devices was easy and highly intuitive.
Zurich University Hospital D
-102
04-2
011
D-1
4395
-200
9
D-1
4469
-200
9
MT-
0821
-200
8
D-1
4281
-200
9
D-1
4190
-200
9
D-2
1994
-200
9
D-1
2634
-200
9
D-1
4546
-200
9
D-1
4586
-200
9
D-1
4537
-200
9
D-1
2369
-200
9
D-1
4168
-200
9
MT-
0819
-200
8
6 | DRÄGER INFINITY® ID-ACCESSORIES
There’s
much more to it
than meets the eye
D-1
4319
-200
9D
-141
76-2
009
D-1
4183
-200
9
D-1
4185
-200
9
D-1
4192
-200
9
D-1
2561
-200
9
D-1
4269
-200
9
D-1
4195
-200
9
D-1
4301
-200
9
D-1
4311
-200
9
D-1
4326
-200
9
D-1
4373
-200
9
D-1
4558
-200
9
| 7
much more to it
than meets the eye
Dräger Infinity® ID-accessoriesSupporting care. Supporting you.
much more to it
than meets the eye
D-1
4395
-200
9
D-1
4469
-200
9
MT-
0821
-200
8
D-1
4281
-200
9
D-1
4190
-200
9
D-2
1994
-200
9
D-1
2634
-200
9
D-1
4546
-200
9
D-1
4586
-200
9
D-1
4537
-200
9
D-1
2369
-200
9
D-1
4168
-200
9
MT-
0819
-200
8
6 | DRÄGER INFINITY® ID-ACCESSORIES
There’s
much more to it
than meets the eye
D-1
4579
-200
9
There’s
much more to it
than meets the eye
D-1
4319
-200
9D
-141
76-2
009
D-1
4183
-200
9
D-1
4185
-200
9
D-1
4192
-200
9
D-1
2561
-200
9
D-1
4269
-200
9
D-1
4195
-200
9
D-1
4301
-200
9
D-1
4311
-200
9
D-1
4326
-200
9
D-1
4373
-200
9
D-1
4558
-200
9
| 7
much more to it
than meets the eye
EXPERIENCES AT THE UNIVERSITY HOSPITAL IN ZURICH*:
“Transferring ventilation settings automatically saves lots of time.”
“Not having to input the data a second time cuts down on user errors, which means a higher level of patient safety.”
“This function makes ventilation parameters transparent.”
“Infinity ID accessories ensure that initial ventilation settings are carried on continuously.”
* The statements here and on the following pages are from a questionnaire completed by at doctors and caregivers at the University Hospital in Zurich
in 2010.
TRANSFER OF VENTILATION SETTINGS (TVS)
Transport your patient while the circuit transports the ventilation settings – from one device to the next.
– Begin in the induction room with a Dräger Primus Infinity Empowered (IE) anesthesia workstation. The Primus stores ventilation settings and alarm limits continuously on an RFID chip inside the Infinity ID breathing circuit – from the first second on.
– Ready to transfer to the operating room? Simply remove the breathing circuit from the Primus IE and move your patient with the circuit into the OR.
– Once you’re there, connect the Infinity ID breathing circuit directly with the Primus IE. The parameters stored on the chip are automatically displayed; all you have to do is confirm and ventilation continues using the same settings.
much more to it
than meets the eye
D-1
4579
-200
9
There’s
much more to it
than meets the eye
D-1
4395
-200
9
D-1
4469
-200
9
MT-
0821
-200
8
D-1
4281
-200
9
D-1
4190
-200
9
D-2
1994
-200
9
D-1
2634
-200
9
D-1
4546
-200
9
D-1
4586
-200
9
D-1
4537
-200
9
D-1
2369
-200
9
D-1
4168
-200
9
MT-
0819
-200
8
6 | DRÄGER INFINITY® ID-ACCESSORIES
There’s
much more to it
than meets the eye
EXCHANGE CONTROL
You‘ll never have to worry about missing an exchange date again – our devices will remind you.
– The Infinity ID water trap from Dräger stores the date of first use on an RFID chip.
– At the end of the 28-day replacement interval, the Primus IE will notify you.
– Now you can exchange the water trap on schedule, avoiding damage to devices caused by using old water traps.
EXPERIENCES AT THE UNIVERSITY HOSPITAL IN ZURICH:
“You can keep your eye on the exchange interval because it’s shown on the display.”
“The additional functionality of the water trap is extremely useful because it avoids damage to the machine.”
There’s
much more to it
than meets the eye
D-1
4319
-200
9D
-141
76-2
009
D-1
4183
-200
9
D-1
4185
-200
9
D-1
4192
-200
9
D-1
2561
-200
9
D-1
4269
-200
9
D-1
4195
-200
9
D-1
4301
-200
9
D-1
4311
-200
9
D-1
4326
-200
9
D-1
4373
-200
9
D-1
4558
-200
9
| 7
much more to it
than meets the eye
EXPERIENCES AT THE UNIVERSITY HOSPITAL IN ZURICH:
“Correction error monitoring improves patient safety because an alarm sounds if a wrong connection is made.”
“Even when you‘re careful, incorrect connections do happen. It’s reassuring to know that the system can recognize an incorrect circuit connection right away.”
MISMATCH CONTROL
Just connect the breathing circuit. The system will help you recognize possible connection errors.
– The Primus IE recognizes the connector of an Infinity ID breathing bag or Infinity ID breathing circuit.
– If a circuit is incorrectly connected, an alarm will sound, enabling you to immediately correct the error.
much more to it
than meets the eye
EXCHANGE CONTROL
You‘ll never have to worry about missing an exchange date again – our devices will remind you.
– The Infinity ID water trap from Dräger stores the date of first use on an RFID chip.
– At the end of the 28-day replacement interval, the Primus IE will notify you.
– Now you can exchange the water trap on schedule, avoiding damage to devices caused by using old water traps.
EXPERIENCES AT THE UNIVERSITY HOSPITAL IN ZURICH:
“You can keep your eye on the exchange interval because it’s shown on the display.”
“The additional functionality of the water trap is extremely useful because it avoids damage to the machine.”
There’s
much more to it
than meets the eye
D-1
4395
-200
9
D-1
4469
-200
9
MT-
0821
-200
8
D-1
4281
-200
9
D-1
4190
-200
9
D-2
1994
-200
9
D-1
2634
-200
9
D-1
4546
-200
9
D-1
4586
-200
9
D-1
4537
-200
9
D-1
2369
-200
9
D-1
4168
-200
9
MT-
0819
-200
8
6 | DRÄGER INFINITY® ID-ACCESSORIES
There’s
much more to it
than meets the eye
EXPERIENCES AT THE UNIVERSITY HOSPITAL IN ZURICH:
“For accessories, the system doesn’t just check to see if it’s a product from a different manufacturer; it also looks to see if it is certified for use. That has a positive impact on the safety of our patients.”
COMPATIBILITY CONTROL
You can count on it: The system automatically checks to make sure if the accessories are approved for use together.
– For example, is the Infinity ID breathing circuit certified for use with the Primus IE?
– If not, the Primus will inform you of this incompatibility as soon as the connection is made, easily avoiding potential hazards for patients and devices.
There’s
much more to it
than meets the eye
D-1
4319
-200
9D
-141
76-2
009
D-1
4183
-200
9
D-1
4185
-200
9
D-1
4192
-200
9
D-1
2561
-200
9
D-1
4269
-200
9
D-1
4195
-200
9
D-1
4301
-200
9
D-1
4311
-200
9
D-1
4326
-200
9
D-1
4373
-200
9
D-1
4558
-200
9
| 7
much more to it
than meets the eye
EXPERIENCES AT THE UNIVERSITY HOSPITAL IN ZURICH:
“This function helps us use the machine more effectively.”
“If the absorber isn’t properly connected, it can translate to risk for the patient, which is why this function makes an important contribution to patient safety.”
LOCK-IN CONTROL
As quick as a click: The anesthesia workstation lets you know if the CLIC Absorber is not firmly connected.
– Is the Infinity ID absorber just parked in its holder on the Primus IE?
– The Primus IE recognizes this problem right away. The system informs you that the absorber is in park position as soon as ventilation begins, which lets you make a firm connection quickly.
much more to it
than meets the eye
EXPERIENCES AT THE UNIVERSITY HOSPITAL IN ZURICH:
“For accessories, the system doesn’t just check to see if it’s a product from a different manufacturer; it also looks to see if it is certified for use. That has a positive impact on the safety of our patients.”
COMPATIBILITY CONTROL
You can count on it: The system automatically checks to make sure if the accessories are approved for use together.
– For example, is the Infinity ID breathing circuit certified for use with the Primus IE?
– If not, the Primus will inform you of this incompatibility as soon as the connection is made, easily avoiding potential hazards for patients and devices.
There’s
much more to it
than meets the eye
D-1
4395
-200
9
D-1
4469
-200
9
MT-
0821
-200
8
D-1
4281
-200
9
D-1
4190
-200
9
D-2
1994
-200
9
D-1
2634
-200
9
D-1
4546
-200
9
D-1
4586
-200
9
D-1
4537
-200
9
D-1
2369
-200
9
D-1
4168
-200
9
MT-
0819
-200
8
6 | DRÄGER INFINITY® ID-ACCESSORIES
There’s
much more to it
than meets the eye
CONFIGURATION CONTROL
Get ready to be more efficient: The system automatically sets all parameters to correspond to those of the Infinity ID breathing circuit.
– The accessory-specific data – for example, for active humidification – is stored in the Infinity ID breathing circuit.
– When you connect the circuit to an Evita Infinity V500 ventilator, all settings are transferred automatically – no need for separate input of the ventilation settings.
CALCULATION OF REMAINING CO2
ABSORBING CAPACITY
Something you can count on: With the help of the absorber, the system automatically calculates the remaining capacity of the soda lime.
– How much soda lime has already been used? Thanks to the Infinity ID CLIC Absorber by Dräger, you won’t ever have to guess again.
– As soon as ventilation begins, the Primus IE simultaneously begins to calculate the remaining CO2 absorption capacity.
– You can see the results on the self-test page of the Primus user interface.
– If 80 % of the soda lime has been used, the system will inform you, giving you time to prepare to replace it.
There’s
much more to it
than meets the eye
D-1
4319
-200
9D
-141
76-2
009
D-1
4183
-200
9
D-1
4185
-200
9
D-1
4192
-200
9
D-1
2561
-200
9
D-1
4269
-200
9
D-1
4195
-200
9
D-1
4301
-200
9
D-1
4311
-200
9
D-1
4326
-200
9
D-1
4373
-200
9
D-1
4558
-200
9
| 7
much more to it
than meets the eye
CONFIGURATION CONTROL
Get ready to be more efficient: The system automatically sets all parameters to correspond to those of the Infinity ID breathing circuit.
– The accessory-specific data – for example, for active humidification – is stored in the Infinity ID breathing circuit.
– When you connect the circuit to an Evita Infinity V500 ventilator, all settings are transferred automatically – no need for separate input of the ventilation settings.
CALCULATION OF REMAINING CO2
ABSORBING CAPACITY
Something you can count on: With the help of the absorber, the system automatically calculates the remaining capacity of the soda lime.
– How much soda lime has already been used? Thanks to the Infinity ID CLIC Absorber by Dräger, you won’t ever have to guess again.
– As soon as ventilation begins, the Primus IE simultaneously begins to calculate the remaining CO2 absorption capacity.
– You can see the results on the self-test page of the Primus user interface.
– If 80 % of the soda lime has been used, the system will inform you, giving you time to prepare to replace it.
There’s
much more to it
than meets the eye
Accessory
Display
User
Device
What exactly are ID-accessories?
Infinity ID-accessories are based on RFID technology, which is short for Radio Frequency Identification. You may have seen RFID technology used in retail stores. If someone tries to remove an article from a store without paying for it, an alarm will sound at the exit thanks to RFID.
With Infinity ID, Dräger has pioneered the use of this technology for clinical use in intensive care units and operating rooms.
INFINITY ID-ACCESSORIES –
QUESTIONS AND ANSWERS
How does RFID technology work with Infinity ID-accessories?
Quite simply: RFID makes a wireless connection between the accessory and the device. When you connect an Infinity ID-accessory to an Infinity ID- device from Dräger, the accessory and the device exchange data. This data is transformed by the device software into useful additional functionality for your daily clinical routine.
Can the radio waves cause harm to myself or my patients?
No, the transmitter power is extremely low. The stored data needs to be transferred only a few centimeters between the accessory and the device. Infinity ID conforms to all current standards for medical products as well as for radio devices.
Can the data on the radio chip get lost?
No, the stored data is always duplicated, which rules out the possibility of losing the data.
Does the chip store patient data?
Yes, but only therapy-relevant data, such as age, weight and size. Names or other personal data are not stored.
8 | DRÄGER INFINITY® ID-ACCESSORIES
D-3
0226
-201
1
| 9
An Infinity ® ID-accessories
overviewM
T-20
99-2
007
Infinity® ID Breathing circuit
MT-
2086
-200
7
Infinity® ID Flow sensor
D-4
2848
-201
2D
-193
83-2
009
Infinity® ID WaterLock® 2
Infinity® ID Expiration valve
MT-
2005
-200
8
Infinity® ID CLIC Absorber Free
D-1
0105
-200
9
Infinity® ID Breathing bag set
10 | DRÄGER INFINITY® ID-ACCESSORIES
ACCESSORY DESCRIPTION
Breathing circuits for adults
Breathing bag sets for adults
Breathing circuits for children
Infinity® ID Breathing Circuit SmoothboreInfinity® ID Breathing Circuit Smoothbore 300Infinity® ID Breathing Circuit CoaxialInfinity® ID Breathing Circuit Watertrap 180Infinity® ID Breathing Circuit Basic 180Infinity® ID Breathing Circuit Basic 250Infinity® ID Breathing Circuit Flex 220Infinity® ID Breathing Circuit Dual HeatedInfinity® ID Breathing Circuit Heated
Infinity® ID Breathing Bag SetInfinity® ID Breathing Bag Set 150
Infinity® ID Breathing Circuit Basic (P) 180Infinity® ID Breathing Circuit Watertrap (P) 180
Breathing bag sets for children
Infinity® ID Breathing Bag Set (P) 110
Breathing bag sets for neonates
Infinity® ID Breathing Bag Set (N) 110
Soda lime container Infinity® ID CLIC Absorber 800+Infinity® ID CLIC Absorber Free
Water trap Infinity® ID WaterLock 2*
Flow sensor Infinity® ID Flow sensor
Expiration valve Infinity® ID Expiration valve (disposable)
Breathing circuits for neonates
Infinity® ID Breathing Circuit Basic (N) 180Infinity® ID Breathing Circuit Watertrap (N) 180Infinity® ID Breathing Circuit Heated (N)
EV
ITA
®
INF
INIT
Y® V
300
PE
RS
EU
S® A
50
0
(SO
FTW
AR
E R
ELE
AS
E 1
.0)
BA
BY
LOG
® V
N5
00
* Fixed exchange interval of 28 days. *** This function is not supported by the Perseus® A500 and Babylog® VN500.** This function is supported only by the Evita® Infinity® V500.
Infinity ® ID-accessories for Primus® IE, Evita® Infinity ® V500 and Babylog ® VN500 from Dräger
DRÄGER DEVICE
PR
IMU
S®
INF
INIT
Y® E
MP
OW
ER
ED
EV
ITA
®
INF
INIT
Y® V
50
0
| 11
Mis
mat
ch c
ontr
ol
Com
patib
ility
con
trol
Exc
hang
e co
ntro
l
Tran
sfer
of v
entil
atio
n
setti
ngs
(TVS
)***
Con
figur
atio
n co
ntro
l**
Lock
-in c
ontr
ol
Cal
cula
tion
of r
emai
ning
C
O2 a
bsor
ptio
n ca
paci
ty**
*
*
PART NO.
MP00340MP01325MP00342MP01326MP01350MP01348MP01347MP00344MP00345
MP00341MP01330
MP01340MP01341
MP01343
MP01329
MX50004MX50120
6872020
6871980
MP01060
MP01327MP01328MP00343
* Fixed exchange interval of 28 days. *** This function is not supported by the Perseus® A500 and Babylog® VN500.** This function is supported only by the Evita® Infinity® V500.
D-1
8862
-201
0D
-680
2-20
11
Primus® Infinity® Empowered
Perseus® A500
D-1
9538
-200
9
Babylog® VN500
D-3
8267
-201
5, D
-434
97-2
012
Evita® Infinity® V500, Evita® Infinity® V300
Infinity ® ID-accessories for Primus® IE, Evita® Infinity ® V500 and Babylog ® VN500 from Dräger
ADDITIONAL FUNCTION
90 6
6 79
5 |
15.
09-3
| C
omm
unic
atio
ns &
Sal
es M
arke
ting
| P
P |
LE
| P
rint
ed i
n G
erm
any
| C
hlor
ine-
free
– e
nvir
onm
enta
lly c
ompa
tible
| S
ubje
ct t
o m
odifi
catio
ns |
© 2
015
Drä
gerw
erk
AG
& C
o. K
GaA
CORPORATE HEADQUARTERSDrägerwerk AG & Co. KGaAMoislinger Allee 53–5523558 Lübeck, Germany
www.draeger.com
REGION CENTRAL AND SOUTH AMERICADräger Panama Comercial S. de R.L.Complejo Business Park, V tower, 10th floorPanama CityTel +507 377 9100Fax +507 377 9130 [email protected]
REGION EUROPE CENTRAL AND EUROPE NORTHDrägerwerk AG & Co. KGaA Moislinger Allee 53–5523558 Lübeck, GermanyTel +49 451 882 0Fax +49 451 882 [email protected]
REGION EUROPE SOUTHDräger Médical S.A.S. Parc de Haute Technologie d’An-tony 225, rue Georges Besse92182 Antony Cedex, FranceTel +33 1 46 11 56 00Fax +33 1 40 96 97 [email protected]
REGION MIDDLE EAST, AFRICADrägerwerk AG & Co. KGaABranch OfficeP.O. Box 505108Dubai, United Arab EmiratesTel +971 4 4294 600Fax +971 4 4294 [email protected]
REGION ASIA / PACIFICDraeger Medical South East Asia Pte Ltd.25 International Business Park#04-27/29 German CentreSingapore 609916, SingaporeTel +65 6572 4388Fax +65 6572 4399 [email protected]
Manufacturer:Drägerwerk AG & Co. KGaAMoislinger Allee 53–5523558 Lübeck, Germany
Locate your Regional Sales Representative at: www.draeger.com/contact