IZM circuit-breakers IN switch-disconnectors up to 6300 A
Modern protection technology covering the rated current range from 630 A to 6300 A.
This overview will assist you to effi ciently use the Moeller concept for the open circuit-breaker IZM. It shows you a whole range of available options and the system involved for function enhancements.
Measurement, signalling, communication- Communication module
Part no. +IZM-COM-DP, Page 11/32
- Measuring module Part no.: +IZM-XMH, Page 11/32
- Display for universal circuit-breaker,Part no. +IZM-XAM,
Page 11/26
- Operations counter Page 11/38
- Position signalling switches For withdrawable unit Part no.: +IZM-XHIAV... Page 11/49
- Auxiliary contacts (Trip-indicating, Availability signal, Spring charge state, Voltage release state)
Part no.: +IZM-XHI... Page 11/36
- Expansion modules Part no.: IZM-XEM-... Page 11/34
Comprehensive fi xed mounted accessories- Main circuit terminals (V = vertical, F = front, A = fl ange) Part no.: +IZM...-XAT...V(F, A)... Page 11/50
- Auxiliary springloaded terminals Part no.: +IZM-XKLZ... Page 11/38
- Door sealing frames, external actuation, IP40
Part no.: IZM-XRT Page 11/44
- Protective cover, transparent, IP55 Part no.: IZM-XDT Page 11/44
High availability- Withdrawable units
Part no.: +IZM...-XAV... Page 11/48
- Arcing chamber covers Part no.: +IZM...-XKLA...-AV Page 11/49
Basic unit- Switching capacity 440 V AC,
Icu = Ics from 50 to 100 kA - 3- or 4 pole- Electronic release for system
protection, selective protection, universal protection and digital release with graphic display
- Rated current In from 630 to 6300 A- Rated voltage Ue 1000 V Part no.: +IZM...-...-X1000V
Page 11/10
Operate with comfort- Motor drives Part no.: +IZM-XM... Page 11/38
- Parameter defi nition systems Part no.: IZM-XEM-...PG...
Page 11/31
- Shunt releases, Part no. +IZM-XA… Page 11/40
- Closing releases Part no.: +IZM-XE...
Page 11/40
- Undervoltage releases Part no.: +IZM-XU... Page 11/42
Circ
uit-
Brea
ker
IZM
fro
m 6
30 A
to
6300
A,
Swit
ch-D
isco
nnec
tor
IN f
rom
630
A t
o 63
00 A
11/1ContentsMoeller HPL0211-2007/2008
Circuit-breakers, switch-disconnectors from 630 to 6300 A
Page
Technical overview
IZM circuit-breakers 11/2
IN switch-disconnectors 11/3
Electronic releases for circuit-breakers 11/4
System overview
Circuit-breakers 11/6
Description
Circuit-breaker, switch-disconnector 11/8
Ordering
IZM1 circuit-breakers, 3 pole …
… For system protection (A) 11/10
… For selective protection (V) 11/10
… For universal protection (U) 11/10
… With digital release (D) 11/10
IZM2 circuit-breakers, 3 pole …
… For system protection (A) 11/12
… For selective protection (V) 11/12
… For universal protection (U) 11/12
… With digital release (D) 11/12
IZM3 circuit-breakers, 3 pole …
… For selective protection (V) 11/14
… For universal protection (U) 11/14
… With digital release (D) 11/14
IZM1 circuit-breakers, 4 pole …
… For system protection (A) 11/16
… For selective protection (V) 11/16
… For universal protection (U) 11/16
… With digital release (D) 11/16
IZM2 circuit-breakers, 4 pole …
… For system protection (A) 11/18
… For selective protection (V) 11/18
… For universal protection (U) 11/18
… With digital release (D) 11/18
IZM3 circuit-breakers, 4 pole …
… For selective protection (V) 11/20
… For universal protection (U) 11/20
… With digital release (D) 11/20
Page
Ordering
Switch-disconnectors, 3- and 4 pole 11/22
Increasing the rated operational voltage to 1000 V AC
11/24
Electronic overcurrent releases 11/25
Test units, rated current module 11/25
Earth-fault protection 11/26
Accessories for electronic overcurrent releases
11/26
Description
Components for communication 11/29
Ordering
Parameter defi nition systems 11/31
Communication and measuring function
11/32
Expansion modules 11/34
Auxiliary contact 11/36
Motor operator 11/38
Closing release, trip block 11/40
Electrically ON, Emergency-Stop, brackets, door seals
11/44
Page
Engineering
Control circuit plug terminal assignment plan
11/45
Ordering
Locking devices 11/46
Locking arrangements 11/47
Withdrawable units 11/48
Ordering, withdrawable units
Withdrawable unit 11/48
Fixed mounting conversion kit for withdrawable units
11/49
Position signalling switch 11/49
Shutters 11/49
Arcing chamber cover 11/49
Coding system 11/49
Ordering
Connection systems for fi xed mounting
11/50
Connection system for withdrawable unit
11/52
Engineering
Selectivity tables 415 V AC 11/54
Tripping characteristics 11/61
Technical data
Permissible continuous current 11/65
Circuit-breakers 11/66
Switch-disconnector 11/72
Control unit 11/76
Auxiliary contact 11/76
Voltage release 11/77
Motor operator 11/77
Current consumption 11/78
Safety clearances 11/78
Dimensions
External dimensions, door cut-out 11/80
Fixed mounting and optional connection terminals, 3 and 4-pole
11/81
Withdrawable units and optional connection terminals, 3 and 4-pole
11/83
Fixed mounted, 3 and 4 pole 11/85
Optional connection terminals 11/86
Measuring transformers, voltage releases
11/91
11/2Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A
Moeller HPL0211-2007/2008 http://catalog.moeller.net
Technical overviewCircuit-breaker
Circuit-breakerwith main switch and isolating characteristics (in combination with the “interlock in OFF” facility) from 630 … 6300 A
Basic switching capacity (B)
Normal switching capacity (N)
High switching capacity (H)
Rated ultimate short-circuit breaking capacity Icu at rated operational voltage Ue
Rated current n = rated uninterrupted current Iu
A
440 V
cu = cs
690 V
cu = cskA
440 V
cu = cskA
690 V
cu = cskA
440 V
cu = cskA
690 V
cu = cskA
1000 V
cu = cskA
IZM
IZM…1(-4)-…50 42 65 50
a
a
IZM…2(-4)-…
a
a
IZM…3(-4)-…
IZM … … … … …
Switching capacitysee above Bsee above Nsee above H
Frame size630 … 1600 A 1800 … 3200 A 24000 … 6300 A 3
Poles3 pole ()4 pole -4
Electronic releases page 11/6
Standard release ASelective-operating release V
Universal release UDigital release D
Rated current in AFrame size 1 630…1600Frame size 2 800…3200Frame size 3 4000…6300
IZM
11/3
Technical overviewSwitch-disconnectors INCirc
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Switch-disconnectorswith main switch and isolating characteristics (in combination with the “interlock in OFF” facility) from 630 … 6300 A
Basic switching capacity (B)
Normal switching capacity (N)
High switching capacity (H)
Rated ultimate short-circuit making capacity cmrated short-time withstand current cw t = 1 s
Rated current n = rated uninterrupted current u
Acm
kAcw
kAcm
kAcw
kAcm
kAcw
kA
IN
IN…1(-4)-…630 … 1600 105 42 143 50
page 11/22
IN…2(-4)-…800 … 3200 121 55 176 65 220 80
page 11/22
INH3(-4)-…4000 … 5000 220 806300 220 100
page 11/23
IN
11/4Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A
Moeller HPL0211-2007/2008 http://catalog.moeller.net
Feature overviewElectronic releases for circuit-breakers
IZM …-A…
System protection630 … 3200 A
IZM …-V…
Selectively-opening circuit-breakers630 … 6300 A
IZM …-U…
Universal protection630 … 6300 A
IZM …-D…
Digital release630 … 6300 A
IZM …-D… + IZM-XZMRDigital release exclusively featur-ing external param-eterization access630 … 6300 A
Basic protective functionsOverload protection Ir L K K K K K
Adjustable delay time tr … … K K K
Short-time delayed short-circuit protection Isd S … K K K K
Non-delayed short-circuit protection Ii I K K2) K K K
Neutral conductor protection N … k K K K
Earth-fault protection G … k k k k
Additional functionsN conductor protection can be … k K K K
Short time delayed short-circuit protection can be activated/deactivated
… … K K K
Non-delayed short-circuit protection can be activated/deactivated
… … K K K
Thermal memory can be activated/deactivated … … K K K
Load monitoring … … K K K
Leading “L” trip signal, 200 ms … … K K K
Short-time delayed short-circuit protection I2t can be selected
… … K K K
Overload protection can be set to I4t … … K K K
Overload protection can be activated/deactivated … … … K K
N conductor protection adjustable … … K K K
Earth-fault protection convertible to I2t … … K K K
Earth fault alarm … … k k k
Selectable parameter sets … … … K K
Zone-selective interlocking … … k k k
Parametric programming and visualizationParametric programming via rotary coding switch K K K … …Parametric programming via communication (absolute values)
… … … K K
Parametric programming via communication … … … K …Remote parameter definition of the basic functions … … … K K
Remote parameter definition of additional functions … … K K K
Setting using parameter assignment module IZM-XEM-PG or PROFIBUS-DP1)
Comm … … … K K
Menu-assisted setting directly on release1) Menu … … … K …Alphanumeric LCD (4-line display) … … k … …Graphic LCD … … … K …
OtherConnection feature for an external 24 V DC power supply
… … K K K
Notes 1) Step size for setting Menu/Comm or Comm
2) Fixed at Ii f 20 x In, max. 50 kA
K standardk optionalSetting range Step width
0 … 11 … 100100 … 500500 … 10001000 … 16001600 … 10 00010 000 … max.
0.11510501001000
IZM
11/5
http://catalog.moeller.net Moeller HPL0211-2007/2008
Technical overviewElectronic releases for circuit-breakers
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
IZM …-A…
System protection630 … 3200 A
IZM …-V…
Selectively-opening circuit-breakers630 … 6300 A
IZM …-U…
Universal protection630 … 6300 A
IZM …-D…
Digital release630 … 6300 A
IZM …-D… + IZM-XZMRDigital release exclusively featur-ing external param-eterization access630 … 6300 A
Measuring function“harmonic” measuring function … … k k k
CommunicationInternal system bus … … K K K
PROFIBUS-DP communication … … k k K
Communication using Ethernet … … k k k
LED display featuresRelease active K K K K K
Alarm 100 % Ir K K K K K
Control unit error message K K K K K
Overload trip L … K K K K
Short-time delayed short-circuit trip S … K K K K
Non-delayed short-circuit trip I … K K K K
Neutral conductor trip N … K1) K K K
Earth-fault protection trip G … K1) K2) K2) K2)
Earth-fault protection alarm G … … K3) K3) K2)
Trip by extended protective function … … K K K
Communication … … K K K
Signals via signalling switch with external system bus modules (relay)
Overload warning 100 % Ir … … K K K
Load shedding, load pick-up … … K K K
Leading overload signal 100 ms … … K K K
Temperature alarm … … K K K
Phase imbalance … … K K K
Overload trip L … … K K K
Short-time delayed short-circuit trip S … … K K K
Non-delayed short-circuit trip I … … K K K
Neutral conductor trip N … … K K K
Earth-fault protection trip G … … K2) K2) K
Earth-fault protection alarm G … … K3) K3) K
Auxiliary relay … … K K K
Control unit error message … … K K K
Notes 1) (only possible with option +IZM-XT)2) (only possible with option (+)IZMU-XT)3) (only possible with option (+)IZMD-XT(A))
K standardk optional
IZM…
11/6Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A
Moeller HPL0211-2007/2008 http://catalog.moeller.net
System overviewCircuit-breakers
01695 910
12
11
11
2
2
17
15
16
13
8 8
1
55
4
7
6
7
3
14
1111
555
IZM
11/7
http://catalog.moeller.net Moeller HPL0211-2007/2008
System overviewCirciut-breakers
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Base units
Circuit-breakers IZM 1Rated current from 630 … 6300 A 4-stage switching capacity4 release types for different protection and indication functions3 and 4-pole versionsa page 11/10
Communication
Communication module 3for PROFIBUS-DP a page 11/32
External expansion modules 2a page 11/35
Electronic releases 11Standard protection functionsOptional protection functionsAdditional functionsParametric programming and visualiza-tionMeasuring functionsCommunicationa page 11/24
Parameter assignment module 12a page 11/31
Earth-fault protection module 13Earth-fault alarm modulea page 11/26
Add-on functions
Position signalling switch 4Module for withdrawable unitModule 1• Connected position: 1 changeover con-
tact• Test position: 1 changeover contact• Disconnected position: 1 changeover
contactModule 2• Connected position: 3 changeover con-
tacts• Test position: 2 changeover contacts• Disconnected position: 1 changeover
contacta page 11/49
Control circuit plugs 7Screw terminals Spring-loaded terminalsa page 11/38
Auxiliary contacts 8Normal auxiliary contacts with 2 N/C and 2 N/O contacts (standard)2 N/C contacts and 2 N/O contacts addi-tionally possibleReady-to-close auxiliary contactsTrip indicationSpring energy store status signalVoltage release status signala page 11/37
Motor operator 9Automatic charging of the stored energy mechanism for ON and OFF operationsMotor cut-off switcha page 11/38
Operations counter 10a page 11/38
Rated current modules 15Rating pluga page 11/25
Emergency-Stop mushroom actuator 16a page 11/44
Voltage release 17Closing release Shunt releaseUndervoltage release• Non-delayed• Off-delayeda page 11/40
Mounting accessories
Terminations 5Horizontal connection (standard)Vertical connectionFront connection (single hole fitting, double hole fitting)Flanged connection (on withdrawable units)a page 11/50
Replacing the switch by insertion and withdrawal
6
3 positions, lockable • Connected position• Test position• Disconnected positionIndication of the positions by position signalling switchArcing chamber cover for reduction of the safety clearanceShutter for automatic locking of the input and output contacts within the withdra-wable unit, lockableReplacing the switch by insertion and withdrawala page 11/48
Door seal 14For door mounting, degree of protection IP40Protective cover to IP55a page 11/44
IZM
11/8Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A
Moeller HPL0211-2007/2008 http://catalog.moeller.net
DescriptionCircuit-breakers, switch-disconnectors
The IZM from Moeller embodies a concept for open circuit-breakers that exceeds the standard throughout the world. Based on state-of-the-art system engineering, the-se switches open up a new dimension in the rated current range from 630 to 6300 A. They excel not only for their performance, but also for their functio-nality, especially in their communications capabilities and their ease of handling and installation.A comprehensive operator manual is supplied with each device.
Coupler switches: Beside the IZM circuit-breakers, IN switch-disconnectors are avai-lable. These are used, for example, as coupler switches between different power supplies.Main switches: You can use both IN switch-disconnectors and IZM circuit-breakers as mains isolating switches. When fitted with a lockable handle, all IZM circuit-bre-akers (and IN switch-disconnectors) fulfil the main switch and isolating characteris-tics according to IEC/EN 60204-1. Depending on the type of apparatus to be protected, the tasks of the circuit-breakers can be split into four main applications:
• System protection• Motor protection• Transformer protection• Generator protection.
These key applications make different demands on the switches, which are met with a range of control units.Switches with closing release are suitable for synchronization tasks.
Numerous locking features are provided or can be fitted by the user, on the one hand to protect the switch and system from unauthorised switching, and on the other for the protection of maintenance and operating personnel.Further safety features are:
• Power feed from top or bottom as required• Standard locking facility for the withdrawable unit when the switch is removed• Standard locking facility for the switch in withdrawable unit to prevent removal• High degree of protection with IP 55 terminal cover• Standard with mechanical closing lockout after overload or short-circuit release• The operating panel cannot be removed when the switch is operational• Delivery including all auxiliary circuit connectors corresponding to built-in fea-
tures including coding device to prevent mix-up of plug-connectors with fixed mounted breakers
• Devices with +IZM-XCOM-DP communication interfacing feature temperature sensors on the built-in microswitch detection units (XBSS) and on the commu-nication module.
IZM circuit-breaker has the following standard equipment:• Electronic overcurrent releases• Rated current module (with the exception of IZM…-A…)• Mechanical ON and mechanical OFF switch• Manual drive for charging the spring-operated stored energy mechanism• Switch position indication 0 / I• Ready indication OK• Charge state display• Auxiliary circuit switch 2 M + 2 B• Horizontal main terminals on rear with fixed mounted and with withdrawable
units up to 5000 A and on rear with vertical main terminals at 6300 A• With 4-pole switches the 4th pole (N) is fitted on the left and can be loaded to
100 %• Display of the contact erosion of the main contacts• Auxiliary current plug system with screw terminals. The switch is always equip-
ped with the required number of auxiliary current plugs.• Mechanically tripped display of the overcurrent release system• Mechanical reclosing lockout after trip• Operation manual in English
Additional with withdrawable units:• Main contacts: Laminated contacts on the back plate of the withdrawable unit,
contact pin on basic unit• Position display with operating console of the plug-in switch• Captive crank handle for switch movement with withdrawable system• Withdrawable unit with guide rails for simple handling• Locking facility for switch movement in the withdrawable unit• The switch cannot be moved in the withdrawable unit in the on state• Rated current coding between the withdrawable unit and the switch.
The compact design of the circuit-breakers provides optimum utilization of the avai-lable space, allowing control panels to be equipped more efficiently. The IZM for a rated current up to 6300 A, for example, can be installed in am 800 mm wide control panel field. Switches with a rated current of 1600 A need only a 400 mm field.
The operating panel is designed to ensure that it can protrude through a cut-out in the door and that all operation elements and displays can be accessed when the control panel door is closed. The operating panels of all switches (fixed mounted/withdrawable, 3/4-pole) are identical. The operating panel provides IP20 degree of protection.
IZM circuit-breakers
Applications
Safety and reliability
Standard version
Design
Operating panel
IZM, IN
11/9
http://catalog.moeller.net Moeller HPL0211-2007/2008
DescriptionCircuit-breakers, switch-disconnectors
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
The new open circuit-breaker IZM covers the entire range from 800 A … 6300 A with just two frame sizes. The compact frame size IZM1 extends the rated current range downwards to 630 A. If required, the range can be extended to 250 A by ex-changing the rating plug. And all this with a setting range of 0.4 … 1 x In.
The IZM devices have the same height and depth across their entire current range. Only their device varies depending on the number of poles and the frame size.
As standard, IZM circuit-breakers are fitted with horizontal connections. Optionally, the following connections are possible: vertical connections, connections that are accessible from the front and flanged connections.
The IZM features microprocessor-controlled control units as standard. Five different control units are available for selection and thus offer optimum protection for your system: From simple system protection with overload and short-circuit release ex-tending to a digital circuit-breaker with graphic display and the option of setting up time-discriminating networks.
The built-in auxiliary switches are connected to the male connector on the switch.Irrespective of the mounting type, the customer connects the auxiliary power circuits to the control circuit plugs at the top of the circuit-breaker. The standard terminals are screw-type; spring-loaded terminals are optional.ON fixed mounting units, the control circuit plugs are fitted directly to the plug con-nectors on the switch and are coded against accidental reversal.To allow withdrawable units to be moved, a sliding contact module is fitted between switch and mounting. The sliding contact module allows a secure connection of the control circuit cable connectors in the “connected” and “test” positions of the switch.
Because components are installed from the front, retrofitting accessories is especial-ly quick and easy. This allows you to respond flexibly to changing requirements within your system.
With their communication-capability, the IZM circuit-breakers open up new possibi-lities in power distribution. Providing and transmitting all important operational in-formation, they increase system transparency and shorten the response times to states such as overcurrent, phase asymmetry and overvoltage. A rapid intervention in a process can, for example, prevent downtimes and help to schedule maintenance activities and therefore boost plant availability.Internal system busThe IZM universal and digital circuit-breakers contain an internal system bus as standard, which connects all intelligent components of the circuit-breaker.Through the communications interface, the information from the intelligent compo-nents can then be transmitted through PROFIBUS-DP, for example with the IZM-XCOM communication module.Expansion modules for the internal system bus:External add-on modules can be connected to the IZM circuit-breakers through the internal system bus without extensive additional wiring. Digital input modules and digital and analog output modules are available for this purpose. A further module implements reduced-time selectivity control between IZM circuit-breakers.
Fundamental criteria for the selection of circuit-breakers:• Max. short-circuit at the point of installation of circuit-breaker Ik max: this value
determines the short-circuit breaking capacity or the short-circuit current car-rying capacity of the circuit-breaker. It is compared with the value Icu, Ics, Icw of the switch and mainly determines the size of the switch a technical data.
• Rated current In which should flow through the respective branch circuit: this value may not be greater than the maximum switch rated current of the circuit-breaker. The rated current is defined with the IZM with the rated current module (exception: overcurrent release for system protection XZMA).
• Ambient temperature of the circuit-breaker: this is generally the internal control panel temperature. Observe the derating table with increased ambient tempe-rature a Technical data.
• Circuit-breaker type: fixed mounted or withdrawable, 3 or 4-pole.• Minimum short-circuit current, which flows through the switchgear: The release
must recognize this value as a short-circuit and may react with a trip.• Protection functions of the circuit-breaker: This is determined by the selection
of the respective overcurrent release.
Operating manual AWB1230-1407D/GB, part no. 232792
Approved circuit-breakers IZM can be found under “Approvals for world markets”.
Current range
Dimensions
Connection by
Control units
Control circuit connections
Modular design
Communication-capability
Selection criteria for IZM circuit-breakers
Documentation
Approvals
IZM, IN
11/10Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
from
630
A t
o 63
00 A
11/11
Moeller HPL0211-2007/2008 Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Ordering OrderingCircuit-breakers, 3-pole Circuit-breakers, 3-pole
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rsfr
om 6
30 A
to
6300
A
Rating data Setting range Basic switching capacity (B) Normal switching capacity (N)
Rated current = rated uninterrupted current
Overload releases
Short-circuit releases Icu = Ics = 50kA at 415 V 50/60 Hz Icu = Ics = 65kA at 415 V 50/60 Hz
Delayed Non-delayed Part no.Article no.
Pricesee price list
Std. pack Part no.Article no.
Pricesee price list
Std. pack NotesIn = Iu Ir Isd Ii
A A A A
IZM…1-…Circuit-breakers for distribution circuit protection (A)
630 315 – 630 1260 … 5040 IZMB1-A630229889
1 off IZMN1-A630229894
1 off • Adjustable overload release Ir = 0.5 – 1 x In• Delay time tr = 10s at 6 x Ir• Adjustable non-delayed short-circuit release Ii = 2 – 8 x In800 400 – 800 1600 … 6400 IZMB1-A800
229890IZMN1-A800229895
1000 500 – 1000 2000 … 8000 IZMB1-A1000229891
IZMN1-A1000229896
1250 625 – 1250 2500 … 10000 IZMB1-A1250229892
IZMN1-A1250229898
1600 800 – 1600 3200 … 12800 IZMB1-A1600229893
IZMN1-A1600229899
Circuit-breaker for selective operation (V) and motor protection630 252 – 630 788 … 7560 12600 IZMB1-V630
2299001 off IZMN1-V630
2299051 off • Adjustable overload release Ir = 0.4 – 1 x In
• Delay time tr = 10s at 6 x Ir• Adjustable delayed short-circuit release Isd = 1.25 – 12 x In• Delay time tsd = 0, 20 (motor protection), 100, 200, 300, 400 ms• Non-delayed short-circuit release Ii f 20 x In
800 320 – 800 1000 … 9600 16000 IZMB1-V800229901
IZMN1-V800229906
1000 400 – 1000 1250 … 12000 20000 IZMB1-V1000229902
IZMN1-V1000229907
1250 500 – 1250 1563 … 15000 25000 IZMB1-V1250229903
IZMN1-V1250229908
1600 640 – 1600 2000 … 19200 32000 IZMB1-V1600229904
IZMN1-V1600229909
Circuit-breaker for universal protection (U) and motor protection630 252 – 630 788 … 7560 945 … 7560, OFF IZMB1-U630
2299131 off IZMN1-U630
2299181 off • Adjustable overload release Ir = 0.4 – 1 x In
• Delay time tr = 2 – 30 s when set to J at 6 x Ir, tr = 1, 2, 3, 4, 5 s when set to I4t• Adjustable N conductor protection In = 0.5 x In, 1 x In, OFF (external transducer required for N conductor)• Adjustable delayed short-circuit release Isd = 1.25 – 12 x In• Delay time tsd = OFF, 20 (motor protection), 100, 200, 300, 400 ms• Adjustable non-delayed short-circuit release Ii = 1.5 – 12 x In; further settings: max. 0.8 x Ics, OFF: Ics = Icw
800 320 – 800 1000 … 9600 1200 – 9600 , OFF IZMB1-U800229914
IZMN1-U800229919
1000 400 – 1000 1250 … 12000 1500 – 12000 , OFF IZMB1-U1000229915
IZMN1-U1000229920
1250 500 – 1250 1563 … 15000 1875 … 15000, OFF IZMB1-U1250229916
IZMN1-U1250229921
1600 640 – 1600 2000 … 19200 2400 – 19200 , OFF IZMB1-U1600229917
IZMN1-U1600229922
Digital circuit-breaker (D) incl. graphic display630 252 – 630 1.25 x In – 0.8 x Icw 1.5 x In – 0.8 x Ics IZMB1-D630
2299231 off IZMN1-D630
2299331 off • Adjustable overload release Ir = 0.4 – 1 x In
• Delay time tr = 2 – 30 s when set to J, tr = 1, 2, 3, 4, 5 s with setting to I4t• Adjustable N conductor In = 0.5 – 2 x In, (external transducer required for N conductor).• Adjustable delayed short-circuit release Isd = 1.25 x In – 0.8 x Icw, with max. setting of 0.8 x Icw the setting of the
delay time tsd is only permissible to max. 400 ms, Icw, see Technical data• Delay time tsd = OFF, 80 – 4000 ms• Observe adjustable non-delayed short-circuit release Ii = 1.5 x In – 0.8 x Ics, OFF: Ics = Icw!• External 24 V DC power supply required (description a “Components for communication”).
800 320 – 800 IZMB1-D800229927
IZMN1-D800229934
1000 400 – 1000 IZMB1-D1000229930
IZMN1-D1000229935
1250 500 – 1250 IZMB1-D1250229931
IZMN1-D1250229936
1600 640 – 1600 IZMB1-D1600229932
IZMN1-D1600229937
Notes rated current reduction: a Accessories “Rated current module”
I I
IZM...1 IZM...1
11/12Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A11/13
Moeller HPL0211-2007/2008 Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Ordering OrderingCircuit-breakers, 3-pole Circuit-breakers, 3-pole
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Rating data Basic switching capacity (B) Normal switching capacity (N) High switching capacity (H)
Rated current = rated uninterrupted current
Setting range Icu = Ics = 55kA at 415 V 50/60 Hz Icu = Ics = 80kA at 415 V 50/60 Hz Icu = Ics = 100kA at 415 V 50/60 Hz
Overload releases
Short-circuit releasesDelayed Non-delayed Part no.
Article no.Pricesee price list
Std. pack Part no.Article no.
Pricesee price list
Std. pack Part no.Article no.
Pricesee price list
Std. pack NotesIn = Iu
A
Ir
A
Isd
A
Ii
A
IZM…2-…Circuit-breakers for distribution circuit protection (A)
800 400 – 800 1600 … 6400 IZMB2-A800225530
1 off IZMN2-A800225534
1 off IZMH2-A800225545
1 off • Adjustable overload release Ir = 0.5 – 1 x In• Delay time tr = 10s at 6 x Ir• Adjustable non-delayed short-circuit release Ii = 2 – 8 x In1000 500 – 1000 2000 … 8000 IZMB2-A1000
225531 IZMN2-A1000
225535 IZMH2-A1000
225546
1250 625 – 1250 2500 … 10000 IZMB2-A1250225532
IZMN2-A1250225536
IZMH2-A1250225547
1600 800 – 1600 3200 … 12800 IZMB2-A1600225533
IZMN2-A1600225537
IZMH2-A1600225548
2000 1000 – 2000 4000 … 16000 IZMB2-A2000229979
IZMN2-A2000225538
IZMH2-A2000225549
2500 1250 – 2500 5000 … 20000 IZMB2-A2500229980
IZMN2-A2500225539
IZMH2-A2500225550
3200 1600 – 3200 6400 … 25600 IZMB2-A3200229982
IZMN2-A3200225540
IZMH2-A3200225551
Circuit-breaker for selective operation (V) and motor protection800 320 – 800 1000 … 9600 16000 IZMB2-V800
2299951 off IZMN2-V800
2300041 off IZMH2-V800
2300141 off • Adjustable overload release Ir = 0.4 – 1 x In
• Delay time tr = 10 s at 6 x Ir• Adjustable delayed short-circuit release Isd = 1.25 – 12 x In• Delay time tsd = 0, 20 (motor protection), 100, 200, 300, 400 ms• Non-delayed short-circuit release Ii f 20 x In, max. 50 kA
1000 400 – 1000 1250 … 12000 20000 IZMB2-V1000229996
IZMN2-V1000230007
IZMH2-V1000230016
1250 500 – 1250 1563 … 15000 25000 IZMB2-V1250229997
IZMN2-V1250230008
IZMH2-V1250230017
1600 640 – 1600 2000 … 19200 32000 IZMB2-V1600229998
IZMN2-V1600230009
IZMH2-V1600230018
2000 800 – 2000 2500 … 24000 40000 IZMB2-V2000229999
IZMN2-V2000230010
IZMH2-V2000230027
2500 1000 – 2500 3125 … 30000 50000 IZMB2-V2500230001
IZMN2-V2500230011
IZMH2-V2500230028
3200 1280 – 3200 4000 … 38400 50000 IZMB2-V3200230003
IZMN2-V3200230012
IZMH2-V3200230029
Circuit-breaker for universal protection (U) and motor protection800 320 – 800 1000 … 9600 1.5 – 12 x In, OFF IZMB2-U800
2255561 off IZMN2-U800
2255601 off IZMH2-U800
2255721 off • Adjustable overload release Ir = 0.4 – 1 x In
• Delay time tr = 2 – 30 s when set to J with 6 x Ir, tr = 1, 2, 3, 4, 5 s with setting to I4 t
• Adjustable N conductor IN = 0.5 x In, 1 x In, (external transducer required for N conductor)
• Adjustable delayed short-circuit release Isd = 1.25 – 12 x In• Delay time tsd = OFF, 20 (motor protection), 100, 200, 300, 400
ms• Adjustable non-delayed short-circuit release Ii = 1.5 – 12 x In,
note further setting values: max. = 0.8 x Ics, OFF: Ics = Icw
1000 400 – 1000 1250 … 12000 1.5 – 12 x In, OFF IZMB2-U1000225557
IZMN2-U1000225561
IZMH2-U1000225573
1250 500 – 1250 1563 … 15000 1.5 – 12 x In, OFF IZMB2-U1250225558
IZMN2-U1250225562
IZMH2-U1250225574
1600 640 – 1600 2000 … 19200 1.5 – 12 x In, OFF IZMB2-U1600225559
IZMN2-U1600225564
IZMH2-U1600225575
2000 800 – 2000 2500 … 24000 1.5 – 12 x In, OFF IZMB2-U2000230069
IZMN2-U2000225565
IZMH2-U2000225576
2500 1000 – 2500 3125 … 30000 1.5 – 12 x In, OFF IZMB2-U2500230070
IZMN2-U2500225566
IZMH2-U2500225577
3200 1280 – 3200 4000 … 38400 1.5 – 12 x In, OFF IZMB2-U3200230071
IZMN2-U3200225567
IZMH2-U3200225578
Digital circuit-breaker (D) incl. graphic display800 320 – 800 1.25 x In – 0.8 x Icw 1.5 x In – 0.8 x Ics IZMB2-D800
2300831 off IZMN2-D800
2300901 off IZMH2-D800
2300971 off • Adjustable overload release Ir = 0.4 – 1 x In
• Delay time tr = 2 – 30 s when set to J, tr = 1, 2, 3, 4, 5 s with setting to I4t
• Adjustable N conductor IN = 0.5 – 2 x In, (external transducer required for N conductor)
• Adjustable delayed short-circuit release Isd = 1.25 x In – 0.8 x Icw, with max. setting of 0.8 x Icw the setting of the delay time tsd is only permissible to max. 400 ms, Icw a Technical data
• Delay time tsd = OFF, 80 – 4000 ms• Observe adjustable non-delayed short-circuit release
Ii = 1.5 x In – 0.8 x Ics, OFF: Ics = Icw!• External 24 V DC power supply required (description a
“Components for communication”).
1000 400 – 1000 1.25 x In – 0.8 x Icw 1.5 x In – 0.8 x Ics IZMB2-D1000230084
IZMN2-D1000230091
IZMH2-D1000230098
1250 500 – 1250 1.25 x In – 0.8 x Icw 1.5 x In – 0.8 x Ics IZMB2-D1250230085
IZMN2-D1250230092
IZMH2-D1250230099
1600 640 – 1600 1.25 x In – 0.8 x Icw 1.5 x In – 0.8 x Ics IZMB2-D1600230086
IZMN2-D1600230093
IZMH2-D1600230100
2000 800 – 2000 1.25 x In – 0.8 x Icw 1.5 x In – 0.8 x Ics IZMB2-D2000230087
IZMN2-D2000230094
IZMH2-D2000230101
2500 1000 – 2500 1.25 x In – 0.8 x Icw 1.5 x In – 0.8 x Ics IZMB2-D2500230088
IZMN2-D2500230095
IZMH2-D2500230102
3200 1280 – 3200 1.25 x In – 0.8 x Icw 1.5 x In – 0.8 x Ics IZMB2-D3200230089
IZMN2-D3200230096
IZMH2-D3200230103
Notes rated current reduction: a Accessories “Rated current module”
I I
IZM...2 IZM...2
11/14Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A11/15
Moeller HPL0211-2007/2008 Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Ordering OrderingCircuit-breakers, 3-pole Circuit-breakers, 3-pole
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Rating dataRated current = rated uninterrupted current
Setting range High switching capacity (H)
Overload releases Short-circuit releases Icu = Ics = 100 kA at 415 V 50/60 HzDelayed Non-delayed Part no.
Article no.Pricesee price list
Std. pack Notes
In = Iu Ir Isd Ii
A A A A
IZM…3-…Circuit-breaker for selective operation (V) and motor protection
4000 1600 – 4000 5000 … 48000 50000 IZMH3-V4000230051
1 off • Adjustable overload release Ir = 0.4 – 1 x In• Delay time tr = 10 s at 6 x Ir• Adjustable delayed short-circuit release Isd = 1.25 – 12 x In• Delay time tsd = 0, 20 (motor protection), 100, 200, 300, 400 ms• Non-delayed short-circuit release Ii f 20 x In, max. 50 kA
5000 2000 – 5000 6250 – 60000 IZMH3-V5000230053
6300 2520 – 6300 7875 – 75600 IZMH3-V6300 1)
232158
Circuit-breaker for universal protection (U) and motor protection4000 1600 – 4000 5000 … 48000 1.5 – 12 x In, OFF IZMH3-U4000
2255801 off • Adjustable overload release Ir = 0.4 – 1 x In
• Delay time tr = 2 – 30 s when set to J with 6 x Ir, tr = 1, 2, 3, 4, 5 s with setting to I4 t • Adjustable N conductor IN = 0.5 x In, 1 x In, (external transducer required for N conductor) • Adjustable delayed short-circuit release Isd = 1.25 – 12 x In• Delay time tsd = OFF, 20 (motor protection), 100, 200, 300, 400 ms• Adjustable non-delayed short-circuit release Ii = 1.5 – 12 x In, note further setting values: max. = 0.8 x Ics,
OFF: Ics = Icw
5000 2000 – 5000 6250 … 60000 IZMH3-U5000225581
6300 2520 – 6300 7875 … 75600 IZMH3-U6300 1)
232159
Digital circuit-breaker (D) incl. graphic display4000 1600 – 4000 1.25 x In – 0.8 x Icw 1.5 x In – 0.8 x Ics IZMH3-D4000
2301041 off • Adjustable overload release Ir = 0.4 – 1 x In
• Delay time tr = 2 – 30 s when set to J, tr = 1, 2, 3, 4, 5 s with setting to I4t• Adjustable N conductor IN = 0.5 – 2 x In, (external transducer required for N conductor)• Adjustable delayed short-circuit release Isd = 1.25 x In – 0.8 x Icw, with max. setting of 0.8 x Icw the setting of
the delay time tsd is only permissible to max. 400 ms, Icw a Technical data• Delay time tsd = OFF, 80 – 4000 ms• Observe adjustable non-delayed short-circuit release Ii = 1.5 x In – 0.8 x Ics, OFF: Ics = Icw!• External 24 V DC power supply required (description a “Components for communication”).
5000 2000 – 5000 IZMH3-D5000230105
6300 2520 – 6300 IZMH3-D6300 1)
232160
Notes rated current reduction: a Accessories “Rated current module”Only vertical version of main terminals possible
I I
IZM...2, IZM...3 IZM...2, IZM...3
11/16Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A11/17
Moeller HPL0211-2007/2008 Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Ordering OrderingCircuit-breakers, 4-pole Circuit-breakers, 4-pole
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Rating dataRated current = rated uninterrupted current
Setting range Basic switching capacity (B) Normal switching capacity (N)Overload releases
Short-circuit releases Icu = Ics = 50kA at 415 V 50/60 Hz Icu = Ics = 65 kA at 415 V 50/60 Hz
Delayed Non-delayed Part no.Article no.
Pricesee price list
Std. pack Part no.Article no.
Pricesee price list
Std. pack NotesIn = Iu Ir Isd Ii
A A A A
IZM...1-4...Circuit-breakers for distribution circuit protection (A)
630 315 – 630 1260 … 5040 IZMB1-4-A630229938
1 off IZMN1-4-A630229943
1 off • Adjustable overload release Ir = 0.5 – 1 x In• Delay time tr = 10 s at 6 x Ir• Adjustable non-delayed short-circuit release Ii = 2 – 8 x In• without overload protection in the 4th pole, therefore not suitable for IT networks
800 400 – 800 1600 … 6400 IZMB1-4-A800229939
IZMN1-4-A800229944
1000 500 – 1000 2000 … 8000 IZMB1-4-A1000229940
IZMN1-4-A1000229945
1250 625 – 1250 2500 … 10000 IZMB1-4-A1250229941
IZMN1-4-A1250229946
1600 800 – 1600 3200 … 12800 IZMB1-4-A1600229942
IZMN1-4-A1600229947
Circuit-breaker for selective operation (V) and motor protection630 252 – 630 788 … 7560 12600 IZMB1-4-V630
2299481 off IZMN1-4-V630
2299531 off • Adjustable overload release Ir = 0.4 – 1 x In
• Delay time tr = 10 s at 6 x Ir• Adjustable delayed short-circuit release Isd = 1.25 – 12 x In• Delay time tsd = 0, 20 (motor protection), 100, 200, 300, 400 ms• Non-delayed short-circuit release Ii f 20 x In• without overload protection in the 4th pole, therefore not suitable for IT networks• (optional with overload protection in the 4th pole: +IZM-XT additionally necessary)
800 320 – 800 1000 … 9600 16000 IZMB1-4-V800229949
IZMN1-4-V800229954
1000 400 – 1000 1250 … 12000 20000 IZMB1-4-V1000229950
IZMN1-4-V1000229955
1250 500 – 1250 1563 … 15000 25000 IZMB1-4-V1250229951
IZMN1-4-V1250229956
1600 640 – 1600 2000 … 19200 32000 IZMB1-4-V1600229952
IZMN1-4-V1600229957
Circuit-breaker for universal protection (U) and motor protection630 252 – 630 788 … 7560 945 7560, OFF IZMB1-4-U630
2299581 off IZMN1-4-U630
2299631 off • Adjustable overload release Ir = 0.4 – 1 x In
• Delay time tr = 2 – 30 s when set to J with 6 It = 1, 2, 3, 4, 5 I4ts with setting to
• Adjustable delayed short-circuit release Isd = 1.25 – 12 x In• Delay time tsd = OFF, 20 (motor protection), 100, 200, 300, 400 ms• Adjustable non-delayed short-circuit release Ii = 1.5 – 12 x In, note further setting values: max. = 0.8 x Ics,
OFF: Ics = Icw!• With overload protection on the 4th pole, can be set to OFF, 100 or 50 % Ir
800 320 – 800 1000 … 9600 1200 9600, OFF IZMB1-4-U800229959
IZMN1-4-U800229964
1000 400 – 1000 1250 … 12000 1500 12000, OFF IZMB1-4-U1000229960
IZMN1-4-U1000229965
1250 500 – 1250 1563 … 15000 1875 15000, OFF IZMB1-4-U1250229961
IZMN1-4-U1250229966
1600 640 – 1600 2000 … 19200 2400 19200, OFF IZMB1-4-U1600229962
IZMN1-4-U1600229967
Digital circuit-breaker (D) incl. graphic display630 252 – 630 1.25 x In – 0.8 x Icw 1.5 x In – 0.8 x Ics IZMB1-4-D630
2299681 off IZMN1-4-D630
2299731 off • Adjustable overload release Ir = 0.4 … 1 x In
• Delay time tr = 2 … 30 s when set to J, tr = 1, 2, 3, 4, 5 s with setting to I4t• Adjustable delayed short-circuit release Isd = 1.25 x In … 0.8 x Icw, with max setting of 0.8 x Icw the setting
of the delay time tsd is only permissible to 400 ms, Icw a Technical data• Delay time tsd = OFF, 80 … 4000 ms• Observe adjustable non-delayed short-circuit release Ii = 1.5 x In … 0.8 x Ics, OFF: Ics = Icw!• With overload protection on the 4th pole, can be set to OFF, 100 % or 50 % Ir• External 24 V DC power supply required (description a “components for communication”)
800 320 – 800 IZMB1-4-D800229969
IZMN1-4-D800229975
1000 400 – 1000 IZMB1-4-D1000229970
IZMN1-4-D1000229976
1250 500 – 1250 IZMB1-4-D1250229971
IZMN1-4-D1250229977
1600 640 – 1600 IZMB1-4-D1600229972
IZMN1-4-D1600229978
Notes 1) rated current reduction: a Accessories “Rated current module”
I I
IZM...1 IZM...1
11/18Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A11/19
Moeller HPL0211-2007/2008 Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Ordering OrderingCircuit-breakers, 4-pole Circuit-breakers, 4-pole
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Rating data Setting range Basic switching capacity (B) Normal switching capacity (N) High switching capacity (H)
Rated current = rated uninterrupted current
Overload releases Short-circuit releases Icu = Ics = 55kA at 415 V 50/60 Hz Icu = Ics = 80kA at 415 V 50/60 Hz Icu = Ics = 100kA at 415 V 50/60 Hz
Delayed Non-delayed Part no.Article no.
Pricesee price list
Part no.Article no.
Pricesee price list
Part no.Article no.
Pricesee price list
Std. pack NotesIn = Iu Ir Isd Ii
A A A A
IZM...2-4...Circuit-breakers for distribution circuit protection (A)
800 400 – 800 1600 … 6400 IZMB2-4-A800225583
IZMN2-4-A800225587
IZMH2-4-A800225598
1 off • Adjustable overload release Ir = 0.5 – 1 x In• Delay time tr = 10 s at 6 x Ir• Adjustable non-delayed short-circuit release Ii = 2 – 8 x In• without overload release in the 4th pole, therefore not suitable for IT networks
1000 500 – 1000 2000 … 8000 IZMB2-4-A1000225584
IZMN2-4-A1000225588
IZMH2-4-A1000225599
1250 625 – 1250 2500 … 10000 IZMB2-4-A1250225585
IZMN2-4-A1250225589
IZMH2-4-A1250225600
1600 800 – 1600 3200 … 12800 IZMB2-4-A1600225586
IZMN2-4-A1600225590
IZMH2-4-A1600225601
2000 1000 – 2000 4000 … 16000 IZMB2-4-A2000230118
IZMN2-4-A2000225591
IZMH2-4-A2000225602
2500 1250 – 2500 5000 … 20000 IZMB2-4-A2500230119
IZMN2-4-A2500225592
IZMH2-4-A2500225603
3200 1600 – 3200 6400 … 25600 IZMB2-4-A3200230120
IZMN2-4-A3200225593
IZMH2-4-A3200225604
Circuit-breaker for selective operation (V) and motor protection800 320 – 800 1000 … 9600 16000 IZMB2-4-V800
230147IZMN2-4-V800230154
IZMH2-4-V800230162
1 off • Adjustable overload release Ir = 0.4 – 1 x In• Delay time tr = 10 s at 6 x Ir• Adjustable delayed short-circuit release Isd = 1.25 – 12 x In• Delay time tsd = 0, 20 (motor protection), 100, 200, 300, 400 ms• Non-delayed short-circuit release Ii f 20 x In, max. 50 kA• without overload release in the 4th pole, therefore not suitable for IT networks • (optional with overload protection in the 4th pole: +IZM-XT additionally
necessary)
1000 400 – 1000 1250 … 12000 20000 IZMB2-4-V1000230148
IZMN2-4-V1000230156
IZMH2-4-V1000230163
1250 500 – 1250 1563 … 15000 25000 IZMB2-4-V1250230149
IZMN2-4-V1250230157
IZMH2-4-V1250230180
1600 640 – 1600 2000 … 19200 32000 IZMB2-4-V1600230150
IZMN2-4-V1600230158
IZMH2-4-V1600230181
2000 800 – 2000 2500 … 24000 40000 IZMB2-4-V2000230151
IZMN2-4-V2000230159
IZMH2-4-V2000230182
2500 1000 – 2500 3125 … 30000 50000 IZMB2-4-V2500230152
IZMN2-4-V2500230160
IZMH2-4-V2500230183
3200 1280 – 3200 4000 … 38400 50000 IZMB2-4-V3200230153
IZMN2-4-V3200230161
IZMH2-4-V3200230184
Circuit-breaker for universal protection (U) and motor protection800 320 – 800 1000 … 9600 1.5 – 12 x In, OFF IZMB2-4-U800
225609IZMN2-4-U800225613
IZMH2-4-U800225624
1 off • Adjustable overload release Ir = 0.4 – 1 x In• Delay time tr = 2 – 30 s when set to J at 6 x Ir, tr = 1, 2, 3, 4, 5 s when set to I4t• Adjustable delayed short-circuit release Isd = 1.25 – 12 x In• Delay time tsd = OFF, 20 (motor protection), 100, 200, 300, 400 ms• Adjustable non-delayed short-circuit release Ii = 1.5 – 12 x In; further settings:
max. 0.8 x Ics, OFF: Ics = Icw• with overload protection in 4th pole, can be set to OFF, 100 % or 50 % Ir
1000 400 – 1000 1250 … 12000 IZMB2-4-U1000225610
IZMN2-4-U1000225614
IZMH2-4-U1000225625
1250 500 – 1250 1563 … 15000 IZMB2-4-U1250225611
IZMN2-4-U1250225615
IZMH2-4-U1250225626
1600 640 – 1600 2000 … 19200 IZMB2-4-U1600225612
IZMN2-4-U1600225616
IZMH2-4-U1600225627
2000 800 – 2000 2500 … 24000 IZMB2-4-U2000230198
IZMN2-4-U2000225617
IZMH2-4-U2000225628
2500 1000 – 2500 3125 … 30000 IZMB2-4-U2500230199
IZMN2-4-U2500225618
IZMH2-4-U2500225629
3200 1280 – 3200 4000 … 38400 IZMB2-4-U3200230200
IZMN2-4-U3200225619
IZMH2-4-U3200225630
Digital circuit-breaker (D) incl. graphic display800 320 – 800 1.25 x In – 0.8 x Icw 1.5 x In – 0.8 x Ics IZMB2-4-D800
230212IZMN2-4-D800230219
IZMH2-4-D800230226
1 off • Adjustable overload release Ir = 0.4 – 1 x In• Delay time tr = 2 – 30 s when set to J, tr = 1, 2, 3, 4, 5 s with setting to I4t• Adjustable delayed short-circuit release Isd = 1.25 x In – 0.8 x Icw, with max.
setting of 0.8 x Icw the setting of the delay time tsd is only permissible to max. 400 ms, Icw a Technical data
• Delay time tsd = OFF, 80 – 4000 ms• Observe adjustable non-delayed short-circuit release Ii = 1.5 x In – 0.8 x Ics,
OFF: Ics = Icw!• With overload protection on the 4th pole, can be set to OFF, 100 or 50 % Ir• External 24 V DC power supply required (description a “Components for
communication”).
1000 400 – 1000 IZMB2-4-D1000230213
IZMN2-4-D1000230220
IZMH2-4-D1000230227
1250 500 – 1250 IZMB2-4-D1250230214
IZMN2-4-D1250230221
IZMH2-4-D1250230228
1600 640 – 1600 IZMB2-4-D1600230215
IZMN2-4-D1600230222
IZMH2-4-D1600230229
2000 800 – 2000 IZMB2-4-D2000230216
IZMN2-4-D2000230223
IZMH2-4-D2000230230
2500 1000 – 2500 IZMB2-4-D2500230217
IZMN2-4-D2500230224
IZMH2-4-D2500230231
3200 1280 – 3200 IZMB2-4-D3200230218
IZMN2-4-D3200230225
IZMH2-4-D3200230232
Notes 1) rated current reduction: a Accessories “Rated current module”
I I
IZM...2 IZM...2
11/20Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A11/21
Moeller HPL0211-2007/2008 Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Ordering OrderingCircuit-breakers, 4-pole Circuit-breakers, 4-pole
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Rating data
Rated current = rated uninterrupted current
Setting range High switching capacity (H) Std. pack Notes
Overload releases Short-circuit releases Icu = Ics = 100 kA at 415 V 50/60 Hz
Delayed Non-delayed Part no.Article no.
Pricesee price list
In = Iu Ir Isd Ii
A A A A
IZM...3-4...Circuit-breaker for selective operation (V) and motor protection
4000 1600 – 4000 5000 … 48000 50000 IZMH3-4-V4000230185
1 off • Adjustable overload release Ir = 0.4 – 1 x In• Delay time tr = 10 s at 6 x Ir• Adjustable delayed short-circuit release Isd = 1.25 – 12 x In• Delay time tsd = 0, 20 (motor protection), 100, 200, 300, 400 ms• Non-delayed short-circuit release Ii f 20 x In, max. 50 kA• without overload release in the 4th pole, therefore not suitable for IT networks • (optional with overload protection in the 4th pole: +IZM-XT additionally necessary)
5000 2000 – 5000 6250 – 50000 IZMH3-4-V5000230186
6300 2520 – 6300 7875 – 50000 IZMH3-4-V6300 1)
232161
Circuit-breaker for universal protection (U) and motor protection4000 1600 – 4000 5000 … 48000 1.5 – 12 x In, OFF IZMH3-4-U4000
2256321 off • Adjustable overload release Ir = 0.4 – 1 x In
• Delay time tr = 2 – 30 s when set to J at 6 x Ir, tr = 1, 2, 3, 4, 5 s when set to I4t• Adjustable delayed short-circuit release Isd = 1.25 – 12 x In• Delay time tsd = OFF, 20 (motor protection), 100, 200, 300, 400 ms• Adjustable non-delayed short-circuit release Ii = 1.5 – 12 x In; further settings:
max. 0.8 x Ics, OFF: Ics = Icw• with overload protection in 4th pole, can be set to OFF, 100 % or 50 % Ir
5000 2000 – 5000 6250 … 60000 IZMH3-4-U5000225633
6300 2520 – 6300 7875 … 75600 IZMH3-4-U6300 1)
232162
Digital circuit-breaker (D) incl. graphic display4000 1600 – 4000 1.25 x In – 0.8 x Icw 1.5 x In – 0.8 x Ics IZMH3-4-D4000
2302331 off • Adjustable overload release Ir = 0.4 – 1 x In
• Delay time tr = 2 – 30 s when set to J, tr = 1, 2, 3, 4, 5 s with setting to I4t• Adjustable delayed short-circuit release Isd = 1.25 x In – 0.8 x Icw, with max. setting of 0.8 x Icw the setting of the delay time tsd is only permissible to max. 400 ms, Icw a Technical data
• Delay time tsd = OFF, 80 – 4000 ms• Observe adjustable non-delayed short-circuit release Ii = 1.5 x In – 0.8 x Ics, OFF: Ics = Icw!• With overload protection on the 4th pole, can be set to OFF, 100 or 50 % Ir• External 24 V DC power supply required (description a “Components for
communication”).
5000 2000 – 5000 IZMH3-4-D5000230234
6300 2520 – 6300 IZMH3-4-D6300 1)
232163
Notes rated current reduction: a Accessories “Rated current module”Only vertical version of main terminals possible
I I
IZM...2, IZM...3 IZM...2, IZM...3
11/22Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A11/23
Moeller HPL0211-2007/2008 Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Ordering OrderingSwitch-disconnectors, 3 and 4 pole Switch-disconnectors, 3 and 4 pole
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Rated current = rated uninterrupted current
Rated short-circuit making capacity
Rated short-time withstand current
Basic switching capacity (B) Normal switching capacity (N) High switching capacity (H)
t = 1 s Part no.Article no.
Pricesee price list
Part no.Article no.
Pricesee price list
Part no.Article no.
Pricesee price list
Std. pack NotesIn = Iu Icm Icw
A kA kA
IN switch-disconnectorsIN...1-... 3 pole 630 105 42 INB1-630
230261INN1-630230274
1 off The INB1(-4)-... switch-disconnector has the same construction as the IZMB1(-4)-... circuit-breaker, however, without electronic trip control. In this manner, it is possible to equip the IN series switch with the same accessory equipment as a comparable IZM circuit-breaker.The INN1(-4)-... switch-disconnector has the same construction as the IZMN1(-4)-... circuit-breaker, however, without electronic trip control. In this manner, it is possible to equip the IN series switch with the same accessory equipment as a comparable IZM circuit-breaker.
800 INB1-800230269
INN1-800230276
1000 INB1-1000230270
INN1-1000230277
1250 INB1-1250230272
INN1-1250230278
1600 INB1-1600230273
INN1-1600230279
4 pole 630 143 50 INB1-4-630230281
INN1-4-630230291
800 INB1-4-800230283
INN1-4-800230293
1000 INB1-4-1000230285
INN1-4-1000230294
1250 INB1-4-1250230287
INN1-4-1250230296
1600 INB1-4-1600230288
INN1-4-1600230297
IN...2-... 3 pole 800 121 55 INB2-800230300
INN2-800230308
INH2-800230315
1 off The INB2(-4)-... switch-disconnector has the same construction as the IZMB2(-4)-... circuit-breaker, however, without electronic trip control. In this manner, it is possible to equip the IN series switch with the same accessory equipment as a comparable IZM circuit-breaker.The INN2(-4)-... switch-disconnector has the same construction as the IZMN2(-4)-... circuit-breaker, however, without electronic trip control. In this manner, it is possible to equip the IN series switch with the same accessory equipment as a comparable IZM circuit-breaker.The INH2(-4)-... switch-disconnector has the same construction as the IZMH2(-4)-... circuit-breaker, however, without electronic trip control. In this manner, it is possible to equip the IN series switch with the same accessory equipment as a comparable IZM circuit-breaker.
1000 INB2-1000230302
INN2-1000230309
INH2-1000230316
1250 INB2-1250230303
INN2-1250230310
INH2-1250230317
1600 INB2-1600230304
INN2-1600230311
INH2-1600230318
2000 INB2-2000230305
INN2-2000230312
INH2-2000230319
2500 INB2-2500230306
INN2-2500230313
INH2-2500230320
3200 INB2-3200230307
INN2-3200230314
INH2-3200230321
4 pole 800 176 65 INB2-4-800230325
INN2-4-800230332
INH2-4-800230339
1000 INB2-4-1000230326
INN2-4-1000230333
INH2-4-1000230340
1250 INB2-4-1250230327
INN2-4-1250230334
INH2-4-1250230341
1600 INB2-4-1600230328
INN2-4-1600230335
INH2-4-1600230342
2000 INB2-4-2000230329
INN2-4-2000230336
INH2-4-2000230343
2500 INB2-4-2500230330
INN2-4-2500230337
INH2-4-2500230344
3200 INB2-4-3200230331
INN2-4-3200230338
INH2-4-3200230345
IN...3-... 3 pole 4000 220 80 INH3-4000230322
1 off
5000 80 INH3-5000230323
6300 100 INH3-63001)
232164
4 pole 4000 80 INH3-4-4000230346
5000 80 INH3-4-5000230347
6300 100 INH3-4-63001)
232165
Notes rated current reduction: a Accessories “Rated current module”1) Only vertical version of main terminals possible
IN...1, IN...2, IN...3 IN...1, IN...2, IN...3
Moeller HPL0211-2007/2008
11/24
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
OrderingIncreasing the rated operational voltage to 1000 V AC
Pole For use with basic unit
Rated operational current
Type suffixOrder number for orders with basic unit
Pricesee price list
Std. pack Notes
Ie
A
Increasing the rated operational voltage to 1000 V AC
3-pole IZMH2-...INH2-...
Up to 2000 A
Up to 2500 A
Up to 3200 A
IZMH3-...INH3-...
Up to 4000 A
Up to 5000 A
Up to 6300 A
4-pole IZMH2-4-...INH2-4-...
Up to 2000 A
Up to 2500 A
Up to 3200 A
IZMH3-4-...INH3-4-...
Up to 4000 A
Up to 5000 A
Up to 6300 A
Electronic overcurrent releasesSystem protection
Selectively-opening circuit-breakers
Selectively-opening circuit-breakers withearth-fault protection and neutral conductor protectionUniversal
Universal with “harmonic” measuring functionRemote
Remote with “harmonic” measuring function
Digital
Digital with “harmonic” measuring function
Notes
IZM2, IZM3, IZM-XZM...
+IZM2-20-X257038+IZM2-25-X257039+IZM2-32-X257040
+IZM3-40-X257041+IZM3-50-X257042+IZM3-63-X257043
+IZM2-204257044+IZM2-254257045+IZM2-324257046
+IZM3-404257047+IZM3-504257048+IZM3-634257049
Part no.Article no.
IZM-XZMA259210IZM-XZMV259211
IZM-XZMV-281344
IZM-XZMU259213IZM-XZMU-281346IZM-XZMR1
259214IZM-XZMR-281348
IZM-XZMD259215IZM-XZMD281410
1) The differcommuni
1000V 1 off A rated operational voltage of 1000 V AC is possible only for INH2-... and INH3-... switch-disconnectors and for IZMH2-... and IZMH3-... circuit-breakers with high switching capacity. Observe reduced values in the technical specifications.
1000V
1000V
1000V
1000V
1000V
-X1000V
-X1000V
-X1000V
-X1000V
-X1000V
-X1000V
Pricesee price list
Std. pack Notes
1 off Order separately for spare part requirement. State the part no. of the circuit-breaker with the order! Order internal wiring separately is required: IZM-XZM-VLIS(-VLEW). Trip release (incl. rated current module IZM-XRP…) must be ordered separately.Control circuit plug X8 is required for the release IZM-XZMU(…), IZM-XZMR(…) and IZM-XZMD(…). If not already available order control circuit plug IZM-XKL-…a Terminal assignment, page 11/5Trip accessories (incl. rating plug IZM-XRP…), please order separately.A rating plug is not included in the equipment supplied and must be ordered separately with an upgrade of the IZM-XZMA to IZMU(R, D).Upgrading of a switch-disconnector by Moeller Field Service is possible.
XT
MH
)
MH1)
-MH
ence to part no. suffix +IZM-XZMR a page 11/27 is that these part numbers do not include the cation interface IZM-XCOM-DP.
11/25
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rs
to 6
300
A
OrderingElectronic overcurrent release and additional functions
Part no.Article no.
Pricesee price list
Std. pack Notes Notes
Internal wiring for retrofitting purposes
Required with upgrade from release XZMA(V) to release XZMU(R)(D)
IZM-XZM-VLIS281411
1 off With release upgrade, the necessary “internal system bus”
With release upgrade from 4-pole IZM with XZMA(V) to
IZM-XZM
Hand-held test unitFor checking that the overcurrent releaseenergy transformer, current transformer aF5 tripping magnet are functioning correcsuitable for all overcurrent releases from02
Hand held test unit
can be exchanged
Rated curuninterrup
In = Iu
A
Rated current module/rating plug
for modification of the release rated current
IZM...-1(-4)-...IZM...-2(-4)-...
250
IZM...-1(-4)-...IZM...-2(-4)-...
315
IZM...-1(-4)-...IZM...-2(-4)-...
400
IZM...-1(-4)-...IZM...-2(-4)-...
500
IZM...-1(-4)-...IZM...-2(-4)-...
630
IZM...-1(-4)-...IZM...-2(-4)-...
800
IZM...-1(-4)-...IZM...-2(-4)-...
1000
IZM...-1(-4)-...IZM...-2(-4)-...IZM...-3(-4)-...
1250
IZM...-1(-4)-...IZM...-2(-4)-...IZM...-3(-4)-...
1600
IZM...-2(-4)-...IZM...-3(-4)-...
2000
IZM...-2(-4)-...IZM...-3(-4)-...
2500
IZM...-2(-4)-...IZM...-3(-4)-...
3200
IZM...-3(-4)-... 4000
IZM...-3(-4)-... 5000
IZM...-3(-4)-... 6300
IZM...-X…
281412
, nd tly;
07/
IZM-XPH226018
IZM-XTES107328
rent = rated ted current
In
Circ
uit-
brea
kfr
om 6
30 A
wiring between the release and X8, if communication functions or an external 24 V DC supply are to be used.X8: 1 – 4
XZMV(U)(R)(D) with neutral conductor or. earth-fault protection, an additional external measurement transducer IZM…-WX… is used a page 11/27
-VLEW 1 off Additional wiring required between release and X8: 9-12 with a release upgrade
1 off With mains cableMains voltages: 220 – 240 V or 110 – 125 V, 50/60 Hz possible.
T 1 off
Part no. suffixOrder number for orders with basic unit
Pricesee price list
Part no.Order number for separate orders
Pricesee price list
Std. pack Notes
+IZM-XRP250230675
IZM-XRP250230622
1 off Not for use with IZM...-A... circuit-breakers for system protectionThe upper limit of the rated uninterrupted current Iu of the circuit-breaker cannot be exceeded.IZM circuit-breaker supplied as standard with rating plug (corresponding to the In of the circuit-breaker).The rating plg is exchanged if the circuit-breaker is ordered with +IZM-XRP….
+IZM-XRP315230676
IZM-XRP315230623
+IZM-XRP400230677
IZM-XRP400230624
+IZM-XRP500230678
IZM-XRP500230625
+IZM-XRP630230679
IZM-XRP630230626
+IZM-XRP800230681
IZM-XRP800230628
+IZM-XRP1000230682
IZM-XRP1000230629
+IZM-XRP1250230683
IZM-XRP1250230630
+IZM-XRP1600230684
IZM-XRP1600230631
+IZM-XRP2000 IZM-XRP2000
230685 230632+IZM-XRP2500230686
IZM-XRP2500230633
+IZM-XRP3200230687
IZM-XRP3200230634
+IZM-XRP4000230688
IZM-XRP4000230635
+IZM-XRP5000230689
IZM-XRP5000230636
+IZM-XRP6300230690
IZM-XRP6300230637
Moeller HPL0211-2007/2008
11/26
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rsfr
om 6
30 A
to
6300
AOrderingElectronic overcurrent release and additional functions
Part no. suffixOrder number for orders with basic unit
Pricesee price list
Std. pack Part no.Order number for separate orders
Pricesee price list
Std. pack Notes
Earth-fault protection with selectively-operating IZM...-V... circuit-breakers
Earth-fault protection (and N-conductor protection with 4-pole circuit-breakers)
+IZM-XT230830
IZM…-U… earth-fault protection for IZM universal circuit-breaker
Earth-fault protection (alarm and trip release)
+IZMU-XT225661
Display for universal circuit-breaker
4-line +IZM-XAM230430
IZM...-X…
1 off
1 off
1 off
Settings:• tg: 0.1 – 0.5 s• Ig: (IZM...1-... and IZM...2-
...): 100, 300, 600, 900, 1200 A
• Ig: (IZM...3-...): 400, 600, 800, 1000, 1200 A
With 3-pole circuit-breakers, an external transducer for the N conductor is required for summation current formation.
IZMU-XT230426
1 off Settings:• tg: 0.1 – 0.5 s• Ig: (IZM...1-... and IZM...2-
...): 100, 300, 600, 900, 1200 A
• Ig: (IZM...3-...): 400, 600, 800, 1000, 1200 A
Through an external transducer, the earth-fault current in the transformer’s star point can alternatively be measured. Commercially available current transformers 1200 A/1 A with an apparent power of Pn = 15 VA can be used. Measuring principle changeover on earth-fault protection module.
With 3-pole circuit-breakers, an external transducer for the N conductor is required for summation current formation.
IZM-XAM232188
1 off Display of:• Currents IL1, IL2, IL3, IN, Ig, maintenance information, trip
cause and phase.In conjunction with measuring function IZM-XZM…-MH display of:• U, P, c, W, f (total harmonic distortion and peak
factor).If ordered separately a control circuit plug IZM-XKL-… is necessary for connection. Order if required, a Terminal assignment, page 11/5.For full functionality an external 24 V DC supply is required (description a „Components for communication“).Without an external power supply the data of the trip are not saved. The phase currents and the set parameters can however be read under the following conditions:• The load on the main conductors is > 80 A (applies for
frame size 1 and 2).
• The load on the main conductors is > 200 A (applies forframe size 3).
11/27
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rsto
630
0 A
OrderingElectronic overcurrent release and additional functions
Part no. suffixOrder number for orders with basic unit
Pricesee price list
Std. pack Part no.Order number for separate orders
Pricesee price list
Std. pack Notes
Earth-fault protection for IZM with digital release IZM...-R(D)...(+IZM-XZMR)
With 3-pole circuit-breakers, an external transducer for the N conductor is required for summation current formation.
Earth-fault protection (alarm and trip release)
+IZMD-X230431
Release variants exclusively with external parameterisation access
for IZM with IZM...-D... digital releasecontained in scope of delivery: communications interface +IZM-XCOM-DP
+IZM-XZ263471
N conductor protection with solely singl
EMV filter
Suppressor for dampening common-mode intby frequency inverters)
IZM-XEM
CT for N conductor and earth-fault prote
Ring-type transformer (Rogowski convertor)IZM…1-
IZM…2-
IZM…3-
Transformers with copper connectionIZM…1-
IZM…2-
IZM…3-
IZM...-X…
T
MR
For use
e pole load in IT–
erference (e.g. in
–
V –
ction
… IZM...-V
IZM...-IZM...-……
… IZM...-IZM...-IZM...-…
…
Circ
uit-
brea
kfr
om 6
30 A
1 off IZMD-XT230432
1 off Settings:• tg: 0.1 – 0.5 s• IZM...1(2)-...: 1000 – 1200 A• IZM...3-...: 400 – 1200 AThrough an external transducer, the earth-fault current in the transformer’s star point can alternatively be measured. Commercially available current transformers 1200 A/1 A with an apparent power of Pn = 15 VA can be used.Menu-driven measuring principle changeover with cursor keys.
External 24 V DC power supply required.This option is not available with the digital circuit-breaker’s graphic display and has no possibility for local operation. For applications with special safety requirements, which can be parameterized only through external access.This ordering position contains the communication interface required for remote parameterization (+IZM-XCOM-DP).
with Part no.Article no.
Pricesee price list
Std. pack Notes
networks+IZM-XIT101529
1 off Only possible with 4 pole circuit-breaker with IZM-XZMV-XT or IZM-XZMU(R, D)…
IT grids, caused
+IZM-XEMV101531
1 off Dampening (asymmetric) in the range from 40 kHz to 10 MHz > 40dB
IZM-XEMV101530
1
... IZM1-XW 1 off With 3-pole circuit-breakers, an external
U...D...230439 transducer for the N conductor is required for the earth-fault protection (for vectorial summation).An auxiliary plug IZM-XKL... is required for connection, order if necessary.a Terminal assignment, page 11/5
IZM2-XW230440
IZM3-XW230441
V...U...D...
IZM1-XWC230442
1 off
IZM2-XWC230443
IZM3-XWC230444
Moeller HPL0211-2007/2008
11/28
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rsfr
om 6
30 A
to
6300
AOrderingElectronic overcurrent release and additional functions
Rated control voltage Part no. suffixOrder number for orders with basic unit
Pricesee price list
Std. pack Part no.Order number for separate orders
Pricesee price list
Std. pack Notes
Us
V
Accessories for electronic overcurrent releases
Cover for setting buttons
Suitable for IZM...A(V)(U) control units and for IZM...D-...+IZM-XZMR (without graphic display)
+IZM-XH230638
Suitable for IZM...D control unit with graphic display (without IZM-XZMR option)
+IZM-XH232190
Automatic reset of the mechanical reclosing lockout
+IZM-XO230783
Remote reset24 DV +IZM-XF
230725DC 125AC 120
+IZM-XF230727
250 DC220 – 240 AC, 50/60 Hz
+IZM-XF230728
IZM-X…
B
BG
W
R24DC
R120AC/125DC
R230AC/250DC
1 off IZM-XHB230639
1 off Sealable cover for setting buttons,with lockable cover for reset button (with key)
1 off IZM-XHBG232191
1 off
1 off • No Reset required after overcurrent trip
• Tripped indicator (red pin) and IZM-XHIA remain as continuous signal
• Switch can be immediately switched on again
• Permissible only if a mechanical manual reset is not essential
1 off Switch is immediately ready for operation again after the Remote Reset command (on condition that the spring-operated stored-energy mechanism is charged automatically by a motor operator).IZM-XFR... includes the IZM-XOW-function:• Automatic reset of the
mechanical reclosing lockout
• Resetting the trip indication (red pin and IZM-XHIA are reset)
X8 control circuit plug required. If not available, order the IZM-XKL-… control circuit plug with the order.a Terminal assignment, page 11/5
11/29
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rs
to 6
300
A
DescriptionComponents for communications
a PROFIBUS-DPb Internal system busc External expansion modules (max. 8 modud Parameter definition of the IZM without ade Parameter assignment module IZM-XEM-Pf IZM-XMH measuring moduleg Communication module IZM-XCOM-DP
Moeller IZM...-U... and IZM...-D... circuit-breacommunication features. Extremely space-effiswitch information.• The circuit-breakers can be parameterized v
overcurrent release. All device-specific data• Built-in circuit-breaker bus for communicat
ring function, switchgear signals, remote mtion
• Connection of external module to the interntoring (also when subsequently upgrading
• Simple connection to PROFIBUS-DP with couniversal and digital circuit-breakers
• The IZM circuit-breakers can be incorporateons based on PROFIBUS-DP. Within the sysmeterized with a programmable logic contrread.
• Switching, controlling and data transfer thr• Data acquisition and power management t
The basic functions of the electronic overcurrewer. With the “Universal” and “Digital” releations which necessitate a data exchange via thare fitted with the internal system bus as standternal 24 V DC power supply is required, whic
• Primary switched-mode power supply uni• 24 V DC, G 3 %• Rated output current: 5 A per circuit-break
of external expansion modules.For example, you can use the Moeller switcheBI7, Article no. 200034.Connection to control circuit connections X8:3modules. The various components are then sunal system bus connection.
Additional functions through the use of:• Communication module• Expansion modules• Measuring module• 4-line display or graphic display• Parameter assignment module
With the 4-line display, the phase currents anwithout an external power supply, as soon as tor 200 A (with IZM...3...) on the main circuit.
If the parameter assignment module is used into an electronic release), it can not be supplie
that case, a standard commercial 24 V DC mains adapter with 5.5 mm jack (plus on the insider) and a load carrying capacity of 500 mA can be used. The mains adapter must meet the SELV regulations.
The IZM-XCOM-DP communication module enables connection of the IZM circuit-breaker to the PROFIBUS-DP. A PROFIBUS master can communicate with the IZM via the DP and DPV1 protocols for monitoring purposes.
Control voltage supply
g
f
a b
c
e
Communication module
IZM
les)ditional softwareG(E)
kers are open circcient, they provid
ia the local interf can be shown.ion between IZM onitoring, trippin
al system bus, fowithout additionammunication mo
d in wide-area cotem, the circuit-boller (PLC). All av
ough central PChrough measuring
nt release do notse it is possible toe internal systemard. For data comh must fulfil the ft
er with the great
d-mode power su
and X8:4 or to o
d
pplied with pow
d the set paramehe load exceeds
Offline mode (i.ed through the in
Circ
uit-
brea
kfr
om 6
30 A
uit-breakers with e all important
ace of the XZMD(R)
and release, measu-g and parameteriza-
r example for moni-l wiring).dule for IZM with
mmunication soluti-reakers can be para-ailable data can be
function
require auxiliary po- use additional func- bus. These devices munications, an ex-
ollowing conditions:
est possible number
pply unit SN4-050-
ne of the expansion
Maintenance information received on time (e.g. via the operating time/hours or via the wear and usage of the main contacts) enables the user to prevent system stand-stills. With threshold violation signals, users can take preventative measures before it comes to a trip. For later analysis with the IZM-XEM-PG parameter assignment module, the relevant data generated when a trip takes place is saved in the device (for example tripping current with date and time).Because the communication module is attached to the frame of the circuit-breaker, the built-in temperature sensor measures the temperature inside the control panel. The switch position is transmitted to PROFIBUS through three microswitches in the underside of the communication module (operating, test or isolated position).All microswitches that record information about the state of the circuit-breaker are installed on or connected to the breaker status sensor (BSS module) for signalling internal switching states. The module provides this digital information (ON, OFF, status of the spring energy store, availability, voltage release) on the built-in system bus. A further temperature sensor determines the temperature in the circuit-breaker. This reading is also made available through a bus line.
The internal system bus used in the circuit-breakers with communication features al-lows various external expansion modules to be connected to the data exchange pro-cess.The available modules include digital output modules, an analog output module, a digital input module and the ZSI module for reduced-time selectivity control. The di-gital output modules with relay outputs are available in a user-programmable ver-sion and a version programmable with a rotary coding switch. The power for the external expansion module is provided by the internal system bus.
“harmonic” measuring function[x263A]With the data and functions provided by the measuring function, the power distribution can be analysed in detail. With the setpoint functions of the measuring functions, users can signal or record specific events in the network. In addition, ex-tended protective functions can be implemented, providing additional tripping con-ditions that are not covered by the overcurrent release.The "harmonic" measuring function determines currents, voltages, ratings, power factors, energy values , frequencies, harmonic distortion, form factors and peak fac-tors.The measuring function provides two additional, independent curve form memories and a frequency analysis up to the 29th harmonic (fast Fourier transformation, or FFT), which can be used for a harmonic compensation.
Internal system bus
er through the inter-
ters can be viewed 80 A (at IZM...1(2)...)
. without connection ternal system bus. In
Moeller HPL0211-2007/2008
11/30
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
DescriptionComponents for communications
This module can output 6 binary data units coses and warnings) of external switching devicswitching off further system components (e.gVarious versions of digital output modules arerotary coding switch. Modules with a rotary cotwo signal blocks, each with six defined assigdelay.The digital output modules are available as veO contact, 150 mA) or with relay outputs (chatwo modules of this type can be connected to
For high-performance solutions, the configurathis unit, any event on the internal system busavailable outputs or three of these outputs ca(“OR” operation). The module can be configuXEM-PGE parameter assignment module (witAs for the output modules with rotary codingOnly one module of this type can be used per
The analog output module can be used in conto output the following measured values of thdevices in the control panel door:
• IL1, IL2, IL3, IN or• UL12, UL23, UL31, UL1N or• PL1, PL2, PL3, Sges or• c1, c2, c3, DI% or• favg, ULLavg, Pges, cavg
Four interfaces (4 … 20 mA/0 … 10 V) are avavalues for output are selected with a rotary cooutput module removes the need for additioninstallation and wiring in the main circuit. Upconnected to an IZM.
With the digital input module, six additional bted to the system. Alternatively, a changeovermotoric and regenerative operation) can be im
Where full selectivity at low delay times is an issue even if the circuit-breakers are arranged in hierarchical groups, the ZSI modules have the solution. They are used to connect the circuit-breakers with each other.If a short-circuit occurs, each circuit-breaker through which short-circuit current flows determines whether the adjacent circuit-breaker on the next lower level is also affected. This allows the exact location of the short-circuit to be identified and only the circuit-breaker immediately upstream of the fault location is tripped.
Digital output module with rotary codin
Digital output module, configurable
Analog output module
Digital input module
ZSI module
IZM
ncerning the swites (e.g. lamps, ho. frequency invert available, both wding switch allow
nments, and an a
rsions with optongeover contacts an IZM.
ble output modu can be switched dn be assigned wired with the IZMh Ethernet interfa switch, a relay ve IZM.
junction with thee circuit-breaker
ilable for this pur
g switch
ding switch. Thal transducers an to two modules
inary signals (24 between two pa
plemented quic
ching state (trip cau-rns, klaxons) or for ers).
ith and without a selection between
dditional response
-coupler outputs (N/ up to 10 A). Up to
le is available. With irectly on one of six
th up to six events -XEM-PG or IZM-ce).rsion are available.
measuring function to analog indication
pose. The measured e use of the analog d their conventional
of this type can be
With the microprocessor-controlled “delayed selectivity control”, the tripping delay of these upstream circuit-breakers can be reduced to up to 50 ms.
The IZM-XEM-PG parameter assignment module with integrated webserver allows access to all device information for analysis or parameterization purposes. The pa-rameter assignment module is connected to the local interface of the overcurrent re-lease and, acting as a Web server, makes the data available through the Hypertext Transfer Protocol (HTTP). With this interface, any PC – desktop, notebook or palm-top – with a Web browser with Java 2 Virtual Machine can become a user interface. The required HTTP files are included as standard.No additional software needs to be installed. The data is displayed in a clear tree structure for quick access. With the parameter assignment module, the switch para-meters can not only be changed, but also saved for later transmission to identical circuit-breakers.Depending on the equipment level of the IZM circuit-breaker, the following values can be displayed: current, voltage, power, energy, c, frequency and harmonics as well as temperature. All status information for the circuit-breaker, warning and trip indications, threshold violations – each with date and time of occurrence, maintenance and statistical in-formation (to reduce or prevent system downtimes).The parameter assignment module is fitted with a magnet on its back, which makes it ideally suited as a portable “online” parameterization and diagnostics tool. Alter-
Parameter assignment module
V DC) can be connec-rameter sets (e.g. for kly and easily.
natively, the parameter assignment module can be used to create and modify para-meter sets offline on a notebook. A printing function allows all processes and settings to be documented on paper.
11/31
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rs
to 6
300
A
OrderingCommunication and measurement
Description Part no.Order number for separate orders
Pricesee price list
Std. pack Notes
Parameter definition systems
Suitable for IZM...-U... and IZM...-D...
Parameter assignment module
• Parameterization, operation, monitoridiagnostics of the IZM circuit-breaker viinterface.• Includes the connectioand null modem cable tInternet Explorer with J
Parameter assignment module with Ethernet interface
• Parameterization, opediagnostics of the IZM cinterface.• Includes the connectioand null modem cable tInternet Explorer with J• With integrated EtherEthernet/Internet/Intran
Connection cable to the X8 terminal
For IZM-XEM-PGE paradevice
Notes
a PROFIBUS-DPb Internal system busc External expansion mod Parameter definition oe Parameter assignmentf Metering module IZMg Communication modu
To use the communicatioThe various components
g
f
a
e
IZM-XEM-…
n cable to the IZMo the PC/Laptop,AVA2 VM 1.4.0-0ration, monitorinircuit-breaker via
n cable to the IZMo the PC/Laptop,AVA2 VM 1.4.0-0net interface for cet.
meter assignmen
dulesf the IZM withou module IZM-XEM-XMHle IZM-XCOM-DP
b
ns interface, an are then supplied
Circ
uit-
brea
kfr
om 6
30 A
ng and a the local
circuit-breaker runs under 1.
IZM-XEM-PG230759
1 off System requirement of the input/output module is a standard browser with Java 2 Virtual Machine (e.g. Internet Explorer, V5.5 or higher or Netscape Navigator, V6.2 or higher). Once the parameter assignment module has been connected to the circuit-breaker, the browser can access the web pages of the parameter assignment module and the data from the circuit-breakers.
g and the local
circuit-breaker runs under 1.onnection to
IZM-XEM-PGE230782
1 off
t and operating IZM-XEM-VLPGE-X8281413
1 off Connection cable for connecting the IZM-XEM-PGE to the X8 terminal strip.For permanent use on a circuit-breaker, which does not feature the IZM-XCOM-DP communication modules or expansion modules.
t additional software-PG(E)
c
d
external 24 V DC power supply must be connected to terminals X8.3 and X8.4. with power through the internal system bus connection (included as standard).
11/32Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A11/33
Moeller HPL0211-2007/2008 Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Ordering OrderingCommunication and measurement Communication and measurement
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Description Part no. suffixOrder number for orders with basic unit
Pricesee price list
Std. pack Part no.Order number for separate orders
Pricesee price list
Std. pack Notes Notes
Communication modules
Suitable for IZM...-U... and IZM...-D...PROFIBUS-DP communication interface
PROFIBUS-DP communication connection including connection cable and BSS module (Breaker Status Sensor) for bus side signalling of internal switching states.With integrated temperature sensor and micro switches for position signalling (for switches in withdrawable units).
+IZM-XCOM-DP230751
1 off IZM-XCOM-DP230833
1 off With use of the communication modules, the installation feature for the IZM-XHIA, -XHIF, -XHIS and -XHIS1 auxiliary contacts is not applicable.The respective signals are detected internally via the Breaker-Status-Sensor and can be accessed with the parameter assignment module, via expansion modules or via the PROFIBUS.
External 24 V DC power supply is required.Description a „Components for communication“The part no. (+)IZM-XCOM-DP already includes the Breaker-Status-Sensor IZM-XBSS.The communication interface (+)IZM-XCOM-DP already includes the Breaker-Status-Sensor and an actuation module which are attached to the base unit. When separately ordering the base unit and the withdrawable unit, the required order options are to be assigned to the basic unit.The +IZM-XBSS plus type is only required however if the internal signals are required, without any further communication interfacing.The IZM-XBSS single type is only intended for spare part requirement.The IZM-XBSS Breaker-Status-Sensor IZM-XBSS is installed in the base unit.
Separate communication module without BSS module
Required with spare part requirement or if the communication interfacing without Breaker-Status-Sensor is to be implemented.
IZM-XCO-DP257028
1 off With use of the communication modules, the installation feature for the IZM-XHIA, -XHIF, -XHIS and -XHIS1 auxiliary contacts is not applicable. The respective signals are only available in conjunction with a BSS module via communication.
Separate Breaker-Status-Sensor (BSS module)
Required with spare part requirement or if the Breaker-Status-Sensor without communication interfacing is to be implemented. Serves for signalling internal switching states on the internal system bus:Main contact ON/OFF, trip indication, spring-charge state signals, ready-to-close indication, voltage trip stateWith integrated temperature sensor.
+IZM-XBSS259201
1 off IZM-XBSS259202
1 off With use of the BSS modules, the installation feature for the IZM-XHIA, -XHIF, -XHIS and -XHIS1 auxiliary contacts is not applicable.The respective signals are detected internally via the Breaker-Status-Sensor and can be accessed with the parameter assignment module or with external expansion modules.
Measurement modules
Suitable for IZM...-U... and IZM...-D...“harmonic” measurement function
The "harmonic" measuring function allow the I, U, P, c, W, fand also distortion factor, peak factor and form factor. Also two independant waveform memories (for current and voltage) and a frequency analysis up to 29th harmonic.An external 3-phase voltage transformer is required for the measuring function.
+IZM-XMH230437
1 off IZM-XMH230835
1 off Configuration of the measuring function (setting of the energy flow direction, transformer primary and secondary voltage and connection type):• For IZM with digital circuit-breaker (IZM...-D...):
menu assisted via graphic display• For IZM with universal circuit-breaker (IZM...-
U...): IZM-XEM-PG(E) parameter assignment module required
External 24 V DC power supply required (description a “Components for communications”).Part no. IZM-XMH can only be order on request.
Voltage transformer (3-phase)
380 … 690 V/100 V Required for measuring function IZM-XW380-690AC101526
1 off 1 voltage transformer can supply up to 6 circuit-breakers with the measurement function “harmonic.
IZM-X... IZM-X...
11/34Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A11/35
Moeller HPL0211-2007/2008 Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Ordering OrderingCommunication and measurement Communication and measurement
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Description Part no. suffixOrder number for orders with basic unit
Pricesee price list
Std. pack Part no.Order number for separate orders
Pricesee price list
Std. pack Notes Notes
Expansion module
Suitable for IZM...-U... and IZM...-D...
Digital output module relay Six digital outputs, time delay adjustable from 0 to 2 s.Outputs optionally assigned with• Signal from overload release, delayed/non-delayed short-circuit release, earth fault alarm/trip and neutral conductor trip or• early make (100 ms) signal from instantaneous overload warning, release electronics fault, load shedding, load pick-up, temperature alarm, current phase asymmetry
IZM-XEM-6DO-R230753
1 off Max. summation current, 6 channels:AC-12, 250 V: 10 ADC-12, 24 V: 10 ADC-12, 250 V: 250 mA
For connection with further modules a prefabricated connection cable is included with each expansion module. The length of the connection cable is 0.2 m.For connection to the switch the longer, prefabricated connection cable IZM-XEM-VL1(VL2)(VLM-X8) is required (not supplied).When the internal switch condition is to be read, a Breaker-Status-Sensor IZM-XBSS is necessary. External 24 V DC power supply required (description a “Components for communication”).For use without a communication module, an IZM-XKL(Z)(-AV) control circuit plug at position X8 is required. Order separately if required.Dimensions W x H x D: 70 x 86 x 95 mmInstallation on 35 mm mounting rail
Digital output module relay, freely programmable
Six digital outputs, programmable with the parameter assignment moduleor via PROFIBUS-DP with additional software (on request)
IZM-XEM-6PDO-R230755
1 off Max. summation current, 6 channels:AC-12, 250 V: 10 ADC-12, 24 V: 10 ADC-12, 250 V: 250 mA
Analog output module Four analog outputs, 4 – 20 mA or 0 – 10 VOutputs optionally assigned with phase currents, phase voltages, effective and apparent power, frequency, power factor
IZM-XEM-4AO230757
1 off
Digital input module Six digital inputs (24 V DC)Transmission of additional information to PROFIBUS-DP
IZM-XEM-6DI230758
1 off
Zone-selective interlocking Optimization of time selectivity IZM-XEM-ZSI230752
1 off Between the setting marks Isd and Ii of the short-circuit protection, the time selectivity can be optimized:• The delay is reduced on all IZM
hierarchical levels to a total of 50 ms.• One module is required per circuit-
breaker.
Connecting cables
For connecting the expansion modules to the built-in system busM 0.2 IZM with communication module IZM-XCOM-DP IZM-XEM-VL05
2308481 off
1 m IZM-XEM-VL1230850
1 off
2 m IZM-XEM-VL2230852
1 off
M 2 IZM without communication module IZM-XCOM-DPConnection to X8
IZM-XEM-VLM-X8281414
1 off
Documentation“IZM – communication solutions” manual AWB1230-1465
2634701 off
Operating instructions IZM/INGerman +AWB1230-1407D
1015401 off AWB1230-1407D
1015331 off Each circuit-breaker is delivered with an operating instruction in
English.When necessary a german operating manual must be seperately ordered (GB-Version will be exchanged for the D-Version).The operating manual is also available as download via Internet.
English AWB1230-1407GB101532
1 off
IZM-XEM-... IZM-XEM-...
11/36Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A11/37
Moeller HPL0211-2007/2008 Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Ordering OrderingAuxiliary contacts Auxiliary contacts
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Rated control voltage Part no. suffixOrder number for orders with basic unit
Pricesee price list
Std. pack Part no.Order number for separate orders
Pricesee price list
Std. pack Notes Notes
Us
V
Auxiliary contacts
Standard auxiliary contactsAdditional 2 make contacts and 2 break contacts +IZM-XHI22
2306051 off IZM-XHI22
2306061 off XHI indicates the position of the main contacts.
Depending on the selected combination the same terminal assignment applies for N/O contact and N/C contact, see terminal assignmentUp to 8 switching contacts or standard auxiliary contacts can be used simultaneouslyStandard on IZM, do not order separately• IZM-XHI standard auxiliary contact with 2 N/O contacts and 2 N/C contacts.The standard terminals are screw-type; spring-loaded terminals are optional.When ordered separately and additional control circuit cable connection may need to be fitted.a Terminal assignment, page 11/5
Additional 3 make contacts and 1 break contact +IZM-XHI31256920
1 off
Four additional make contacts +IZM-XHI40256921
1 off
2 make contacts IZM-XHI20256922
1 off
1 make contact and 1 break contact IZM-XHI11256923
1 off
Trip-indicating auxiliary contacts 1 C/O +IZM-XHIA
2634761 off IZM-XHIA
2634751off Optionally, signals trip caused by the overcurrent release: overload, short-circuit and earth-
fault tripping.ON remote switching through shunt release or undervoltage release, the IZM (unlike the NZM switch-disconnectors) does not go into its tripped position. When the circuit-breaker is fitted with the communication interfacing IZM-XCOM-DP or IZM-XBSS, the connection XHIA to X7 is not required. The signal can be accessed via the communication interface. The standard terminals are screw-type; spring-loaded terminals are optional.
1 changeover contactNecessary for IZM circuit-breakers with metal system carrier (07/2005)
IZM-XHIA-M101527
1 off
Availability signal1 make contact +IZM-XHIB
2256801 off IZM-XHIB
2258761 off Availability is also signalled locally by the OK indication and means:
• Mechanical reclosing lockout reset (red reset pin)• Spring energy store tensioned• Undervoltage release excited• Shunt release not excited• Electrical interlock in the plant control cancelled• Mechanical interlock ineffective• Locking devices not activatedThe standard terminals are screw-type; spring-loaded terminals are optional.
Spring energy store status signal 1 make contact +IZM-XHIF
2569251 off IZM-XHIF
2569241 off “Spring-operated stored energy mechanism charged” is one of several preconditions for
availability.The standard terminals are screw-type; spring-loaded terminals are optional.On circuit-breaker featuring communication connection IZM-XCOM-DP or IZM-XBSS the terminal slot for XHIF on X7 is not required. The signal of the XHIS can be read via the communication.If ordered separately a control circuit plug IZM-XKL-… is necessary for connection. Order if required.a Terminal assignment, page 11/5
Voltage release status signal 1 N/O for the 1st shunt release or for the 2nd
voltage release (+IZM-XA1..., IZM-XE/A..., (+)IZM-XU(V)...)
+IZM-XHIS230713
1 off IZM-XHIS230714
1 off XHIS and XHIS1 are of identical design
Signals whether the shunt release/undervoltage release is excited/de-energised. XHIS and XHIS1 are of identical design. When ordering separately, always choose XHIS. Up to two XHIS(1) auxiliary switches can be used.On circuit-breaker featuring communication connection IZM-XCOM-DP or IZM-XBSS the terminal slots for XHIS and XHIS1 on X7 are not required. The signal of the XHIS can be read via the communication.The standard terminals are screw-type; spring-loaded terminals are optional.If ordered separately a control circuit plug IZM-XKL-… is necessary for connection. Order if required.a Terminal assignment, page 11/5
1 N/O contact for the 2nd voltage release (+IZM-XA1…, IZM-XE/A…, (+)IZM-XU(V)…)
+IZM-XHIS1256926
1 off XHIS and XHIS1 are of identical design
IZM-XHI… IZM-XHI…
11/38Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A
Moeller HPL0211-2007/2008 Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Ordering OrderingMotor operator Motor operator
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Rated control voltage
Part no. suffixOrder number for orders with basic unit
Pricesee price list
Std. pack Part no.Order number for separate orders
Pricesee price list
Std. pack Notes Notes
Us
V
Motor operator24 – 30 DC +IZM-XM24-DC
2305381 off IZM-XM24-DC
2305391 off Automatic charging of the spring-operated stored energy mechanism
Standard: customer connection as screw terminalsIf ordered separately a control circuit plug IZM-XKL-… is necessary for connection. Order if required.a Terminal assignment, page 11/5For remote operator and additional closing release and shunt release or undervoltage release is required.
48 – 60 DC +IZM-XM48-60DC230540
1 off IZM-XM48-60DC230541
1 off
110 – 125 DC110 – 127 AC
+IZM-XM110AC/DC230542
1 off IZM-XM110AC/DC230543
1 off
220 – 250 DC208 – 240 AC
+IZM-XM230AC/220DC230544
1 off IZM-XM230AC/220DC230545
1 off
Motor cut-off switchThumb-grip handle +IZM-XMS
2307171 off IZM-XMS
2307181 off Can not be combined
with electrical ON,Only for switches with motor-operator
Operations counterMechanical, 5-position +IZM-XSZ
2307291 off IZM-XSZ
2592161 off Only possible with
motor-operatorThe operations counter can be used only in combination with the motor operator.
Control circuit connections
Spring-loaded fixed mounting +IZM-XKLZ256914
1 off Standard: customer connection as screw terminalsEach switch is equipped with the required number of auxiliary connections to match the installed accessories. On fixed mounted breakers these are protected against incorrect insertion with a coding pin.When accessories are being fitted, the auxiliary connections may need to be supplemented.a Terminal assignment, page 11/5
Spring-loaded terminals, withdrawable modules +IZM-XKLZ-AV256915
1 off
Individual parts for replacement or retrofittingScrew-type manual connector IZM-XKL-HS
2569191 off See also AWB1230-1407 (06/05)
Wiper contact, withdrawable
a Standard: with screw terminalsb Optional: screw-type terminal connectionc Optional: Spring-loaded terminalsd Option: please order positions b or c separately.e Plug on basic device
Spring-loaded manual connector IZM-XKL-HZ256918
1 off
Plug connector IZM-XKL-ML259207
1 off
Sliding contact module (optional)for combination with IZM-XKL-H…
IZM-XKL-SK259208
1 off Wiper contact, withdrawable
Blanking block IZM-XKL-B256917
1 off
Coding set for 4 hand connectors, fixed mounting IZM-XKL-C256916
1off Prevents reversal of control circuit plugs, for example during maintenance.
Wiping contact module with screw terminals IZM-XKL-SS101523
1 off
Adapter - plug connectorFor 1000 V switch IZM-XKL-AML-1000V
2634721 off One off required per
control circuit connector (only for subsequent ordering of accessories).
01695
IZM-XKL-ML
e
IZM-XKL-SK
d
IZM-XKL-HZ
c
IZM-XKL-HS
b
IZM-XKL-SS
a
IZM-XM…, IZM-XKL-... IZM-XM…, IZM-XKL-…
11/39
11/40Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A11/41
Moeller HPL0211-2007/2008 Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Ordering OrderingClosing release, trip block Closing release, trip block
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Rated control voltage Part no. suffixOrder number for orders with basic unit
Pricesee price list
Std. pack Part no.Order number for separate orders
Pricesee price list
Std. pack Notes Notes
Us
V
Closing releases
Closing release100 % duty factor24 DC – +IZM-XE24DC
2305641 off IZM-XE/A24DC
2305651 off Closing releases and shunt releases have the same construction.
The function is determined by the position where they are installed.
A closing release is necessary for remote-ON.Remote-OFF must be implemented by the shunt release or the undervoltage release.In addition to the closing release it is possible to install:• up to two shunt releases or• a shunt release and an undervoltage release
DC – 30 +IZM-XEDC230566
IZM-XE/A30DC230567
DC – 48 +IZM-XE48DC230568
IZM-XE/A48DC230569
DC – 60 +IZM-XE60DC230570
IZM-XE/A60DC230571
110 DC110 AC, 50/60 Hz
+IZM-XE110AC/DC230572
IZM-XE/A110AC/DC230573
220 DC230 AC, 50/60 Hz
+IZM-XE230AC/220DC230574
IZM-XE/A230AC/220DC230575
Over-excited closing releaseRetrieval time: 25 ms5 % duty factor24 DC – +IZM-XE24DC05
2305761 off IZM-XE/A24DC05
2305771 off Not suitable for uninterrupted operation.
With cut-off switch (internal auxiliary switch).DC – 48 +IZM-XE48DC05
230578 IZM-XE/A48DC05
230579
110 – 125 DC110 – 127 AC, 50/60 Hz
+IZM-XE110AC/DC05230580
IZM-XE/A110AC/DC05230581
220 – 250 DC208 – 240 AC, 50/60 Hz
+IZM-XE230AC/DC05230582
IZM-XE/A230AC/DC05230583
Shunt releases
First shunt release100 % duty factor24 DC – +IZM-XA24DC
2305461 off For separate order, select part no. IZM-XE/A...
Closing releases and shunt releases have the same construction. The function is determined by the position where it is installed.
For Remote ON, a closing release is required.Remote OFF must be implemented with shunt releases or undervoltage releases.The following can be fitted in addition to the closing release:• Up to two shunt releases or• one shunt release and one undervoltage releaseCapacitor store on request.
DC – 30 +IZM-XA30DC230548
48 DC – +IZM-XA48DC230550
DC – 60 +IZM-XA60DC230552
110 DC110 AC, 50/60 Hz
+IZM-XA110AC/DC230554
220 DC230 AC, 50/60 Hz
+IZM-XA230AC/220DC230556
IZM-XE… , IZM-XA… IZM-XE… , IZM-XA…
11/42Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A11/43
Moeller HPL0211-2007/2008 Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Ordering OrderingClosing release, trip block Closing release, trip block
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Rated control voltage Part no. suffixOrder number for orders with basic unit
Pricesee price list
Std. pack Part no.Order number for separate orders
Pricesee price list
Std. pack Notes Notes
Us
V
Shunt releases
Second shunt releases100 % duty factor24 DC – +IZM-XA1(24DC)
2307601 off IZM-XE/A24DC
2305651 off For separate order, select part no. IZM-XE/A...
Closing releases and shunt releases have the same construction. The function is determined by the position where it is installed.A control circuit plug IZM-XKL-... is required for the connection when ordered separately. Order separately if required.a Terminal assignment, page 11/5
For Remote ON, a closing release is required.Remote OFF must be implemented with shunt releases or undervoltage releases.The following can be fitted in addition to the closing release:• Up to two shunt releases or• one shunt release and one undervoltage releaseCapacitor store on request.
DC – 30 +IZM-XA1(30DC)230762
IZM-XE/A30DC230567
DC – 48 +IZM-XA1(48DC)230764
IZM-XE/A48DC230569
DC – 60 +IZM-XA1(60DC)230766
IZM-XE/A60DC230571
110 DC110 AC, 50/60 Hz
+IZM-XA1(110AC/DC)230768
IZM-XE/A110AC/DC230573
220 DC230 AC, 50/60 Hz
+IZM-XA1(230AC/220DC)230770
IZM-XE/A230AC/220DC230575
Undervoltage releases
Short-time delay (200 ms) possible with jumper24 DC – +IZM-XU24DC
2305841 off IZM-XU24DC
2305851 off A control circuit plug IZM-XKL-… is required for the connection
when ordered separately. Order separately if required.a Terminal assignment, page 11/5
A closing release is necessary for remote-ON.Remote-OFF must be implemented by the shunt release or the undervoltage release.In addition to the closing release it is possible to install:• up to two shunt releases or• a shunt release and an undervoltage release
DC – 30 +IZM-XU30DC230586
IZM-XU30DC230587
48 DC – +IZM-XU48DC230588
IZM-XU48DC230589
60 DC +IZM-XU60DC101525
IZM-XU60DC101524
110 – 125 DC110 – 127 AC, 50/60 Hz
+IZM-XU127AC/125DC230591
IZM-XU127AC/125DC230592
220 – 250 DC208 – 240 AC, 50/60 Hz
+IZM-XU240AC/250DC230593
IZM-XU240AC/250DC230594
380 – 415 AC, 50/60 Hz +IZM-XU415AC230595
IZM-XU415AC230596
Delayeddelay time 0.2 – 3.2 sDC – 48 +IZM-XUV48DC
2305971 off IZM-XUV48DC
2305981 off With second input for non-delayed release.
A control circuit plug IZM-XKL-… is required for the connection when ordered separately. Order separately if required.a Terminal assignment, page 11/5
110 – 125 DC110 – 127 AC, 50/60 Hz
+IZM-XUV127AC/125DC230599
IZM-XUV127AC/125DC230600
220 – 250 DC208 – 240 AC, 50/60 Hz
+IZM-XUV240AC/250DC230601
IZM-XUV240AC/250DC230602
380 – 415 AC, 50/60 Hz +IZM-XUV415AC230603
IZM-XUV415AC230604
IZM-XA… , IZM-XE… , IZM-XU… IZM-XA… , IZM-XE… , IZM-XU…
Moeller HPL0211-2007/2008
11/44
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rsfr
om 6
30 A
to
6300
AOrderingElectrically ON, emergency-stop, brackets, door seals
Part no. suffixOrder number for orders with basic unit
Pricesee price list
Part no.Order number for separate orders
Pricesee price list
Std. pack Notes
Electrical ON
Can not be combined with motor cut-off switch,Can not be combined with communication module,Can be used only in combination with closing release,If required, order cover for mechanical ON (IZXVD...) separately
Push-button with sealabshroudSafety lock, Make: CES
Emergency-Stop actuator
Mounting brackets for fixed mounted cirbreakers
Door seal
Protective cover
IZM…-X...
M-
le +IZM23072+IZM23072
+IZM23064
Part Articl
cuit-
IZM123073
IZM-X23073
IZM2307
-XEE-TP1
IZM-XEE-TP230722
1 off If ordered separately a control circuit plug is necessary for connection. Order if requireda Terminal assignment, page 11/5Order cover for mechanical ON (IZM-XVD…) separately, if required.
-XEE-C3
IZM-XEE-C230724
1 off
-XPV6
IZM-XPV230647
1 off mushroom actuator instead of the mechanical OFF-actuator
no.e no.
Pricesee price list
Std. pack Notes
/2-XTW1
1 off 1 pair, wall mounting for:• IZM...1-...• IZM...2-...• IN...1-...• IN...2-...
RT0
1 off For door cut-out with degree of protection IP40, cover of the door cut-out
-XDT50
1 off Degree of protection IP55, transparent,Can not be combined with door sealing frame.Shroud removable or can be opened to left or right.
11/45
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rs
to 6
300
A
EngineeringControl circuit plug terminal assignment plan
X814
13
12
XFR remote reset
G-converter S2
IZM-XW(IZM-XW(
External voltageExternal voltagExternal voltagExternal voltag
XH
XHIS signall
XHIS signalling
XHI sta
XHIB
XHI sta
XA1
Standard auxiliary contact XHI11/XHI22/
Standard auxiliary contact XHI11/XHI22/
Standard auxiliary contact XHI22:
Standard auxiliary contact XHI22:
X
XHI st
XHI st
Internal Terminals ExternalControl circuit plug IZM-XKL(-AV) for customer connection (a page 11/38)Control circuit plugs X8, X7, X6, X5 are identical
X8: optional control circuit plug(Connections X8:1 to X8:8 only with IZM…-U… and IZM…-D…)
X7: optional control circuit plugNot available with IZM-XCOM-DP communication function. The communications module is at positionX7.
X6: standard control circuit plug
X5: optional control circuit plug
L/L+ UsN/L-e.g. converter transformer star aelectronic
overload release
InternIntern
XHIA tripped
IF spring-operatmecha
ing switch on firs
switch on second
XE/A fi
ndard auxiliary s
XE/
“ready to close”
ndard auxiliary s
, XU, XUV second
XHI31: S3“NO”, X
XHI31: S3“NC”, X
S4“NO”, XHI31/X
Only XUV “n
andard auxiliary s
andard auxiliary s
XEE e
S4“NC”, XHI31
MS optional mo
Circ
uit-
brea
kfr
om 6
30 A
11
10
9
8
7
6
5
4
3
2
1
X714
13
12
11
10
9
8
7
6
5
4
3
2
1
X614
13
12
11
10
9
8
7
6
5
4
3
2
1
X514
13
12
11
10
9
8
7
6
5
DPWrite
FreeFree
CloseO
penO
UT
XA,XU
XEIN
12
34
56
78
9ExternalInternal
Enable– +
– +– +
a
G-converter S1C) N-converter S2C) N-converter S1 transformer stare transformer L3e transformer L2e transformer L1
0 V DC24 V DC
al system bus +al system bus …
signalling switch
ed stored energynism state signal
t voltage release
voltage release
rst shunt release
witch: S1 "N/O"
A closing release
auxiliary switch
witch: S2 "N/O"
voltage release
HI40: S7 "N/O"
HI40: S7 "N/O"
HI40: S8 "N/O"
on-delayed trip”
witch: S2 "N/C"
witch: S1 "N/C"
L1L2L3N
24 V DC external power supply
L/L+ Us
Terminating resistor, (120 O) no external system bus module
IZM-XCOM-DP
Emergency-stop or jumper
point or summation current transformer 1200 A/1 A
Jumper if no N-converter
L/L+ UsN/L-
UsL/L+N/L-
L/L+ UsN/L-
lectrically “ON”
4
3
2
1
Ma b
/XHI40: S8 "N/O"
Motor operatorstor cut-off switch
L/L+ UsN/L-
a black-whiteb brown
Moeller HPL0211-2007/2008
11/46
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rsfr
om 6
30 A
to
6300
AOrderingLocking devices
Part no. suffixOrder number for orders with basic unit
Pricesee price list
Part no.Order number for separate orders
Pricesee price list
Std. pack
Notes
ON and OFF key locking facility
Locking set with two covers for padlocks or seal, two covers for tool operation and two lock barrel holders
+IZM-XVD230642
IZM-XVD230645
1 off Prevents local switching. Electrical remote operation is still
Locking set as before, but with a CES safety lock
Locking device, locking in OFF1)
With CES safety lock
With Ronis safety lock
Castell mounting kit
Locking shackle, for up to four 6 mm padlockslockable
Locking in OFF position, independently of switch, only for withdrawable modules (CES lock in control panel door)
Locking as previously with additional Ronis safety lock
Locking device to prevent movement of the circuit-breaker in the withdrawable unit
Prevents movement of the switch in the withdrawable unitLocking of the crank handle to prevent movement (lock beside the crank handle); make: CESLock to prevent movement out of the disconnected position (lock in the control panel door); make: CESLocking as previously with additional Ronis safety lock
Operator lever locking facility
Hand lever can be locked with a padlock.
Notes
IZM-XV...
+IZM-XVDM230640
+IZM-XVDM263860
+IZM-XVDM230641
, +IZM-XVDM230778
+IZM-XVZ-A263436
+IZM-XVZ-R263438
+IZM-XVK-A230648
+IZM-XV-AV230650
+IZM-XV-R-
2634631) For mechano effect.
possible.Can be locked with a 6 to 8 mm padlock.Padlock and barrel lock are not supplied.
IZM-XVD-CES256975
1 off Prevents local switching. Electrical remote operation is still possible.
IZM-XVDM230643
1 off Locking in OFF position fulfils isolator conditions
-R IZM-XVDM-R263861
Locking in OFF position fulfils isolator conditions
E-C IZM-XVDME-C230644
Locking in OFF position fulfils isolator conditions.The lock is not included as standard.
V IZM-XVDMV230779
Locking in OFF position fulfils isolator conditions.Padlocks are not included as standard.
V IZM-XVZ-AV256986
Locking in OFF position fulfils isolator conditions.
-AV IZM-XVZ-R-AV263437
Cannot be combined with (+)IZM-XVK-AV and IZM-XVV.
V IZM-XVK-AV230649
1 off Can not be combined with (+)IZM-XV-AV and IZM-XVV.
IZM-XV-AV230651
AV IZM-XV-R-AV263464
IZM-XVS256987
1 off Prevents manual charging of the spring energy store.The padlock is not included as standard.
nical interlock with (+) IZM-XVDM… there is simultaneously an electrical interlock, i.e. closing release has
11/47
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rsto
630
0 A
OrderingLocking devices
Part no. suffixOrder number for orders with basic unit
Pricesee price list
Part no.Order number for separate orders
Pricesee price list
Std. pack Notes
Door interlockFor fixed mounting, effective when switch in ON position
+IZM-XVT230652
IZM-XVT 1 off Interlock can be overridden with tool
For withdrawable units, effective in connected position
+IZM-XVT-AV230654
Locking arrangement
Locking arrangement for open control panel utilization prevention
+2
Mechanical interlock
Mechanical interlock with Bowden cables for 2 or 3 IZM/IN switches (side-by-side or above each other)
Assembly kit for one fixed mounting switch, with 2 m Bowden cables
+2
Assembly kit for one withdrawable switch, with 2 m Bowden cables
+2
Adapter set, required from withdrawable units of frame size 3
+A2
2 m Bowden cables
3 m Bowden cables
4.5 m Bowden cables
6 m Bowden cables
Individual components for replacement or when ordering withdrawable unit and switch for AV separately
Individual components for replacement purposes or with separate order of withdrawable unit and switch for withdrawable unit.
Intermediate shaft with coupling
Mechanical locking module for withdrawable unit, with 2 m Bowden cables
IZM-XV..., IZM-XMV...
IZM-XVV30660
IZM-XMV30662
IZM-XMV-AV30663
IZM3-XMVAS-V63473
Circ
uit-
brea
kfr
om 6
30 A
230653IZM-XVT-AV230655
1 off Interlock can be overridden with tool
IZM-XVV230661
1 off Can not be combined with (+)IZM-XVK-AV and IZM-XV-AVV.
IZM-XMV232168
1 off Order an assembly kit with each switch
IZM-XMV-AV232169
Order an assembly kit with each switchFor IZM(IN)...3-..., one additional adapter set required per switch:(+)IZM3-XMVAS-AV
IZM3-XMVAS-AV263474
For withdrawable IZM(IN)...3-..., one additional adapter set required per switch:
IZM-XMVB200232176
For triple interlocks, additional Bowden cables may, depending on the application, be required (see operating manual AWB1230-1407D/GB, section 18).
IZM-XMVB300232177IZM-XMVB450232178IZM-XMVB600232179
IZM-XMVAD232175
1 off Installation on the switch for withdrawable unit.(IZM-XMV-AV) = (IZM-XMVAD) + (IZM-XMVAD-AV)
IZM-XMVAD-AV259206
1 off For fitting to the withdrawable unit.(IZM-XMV-AV) = (IZM-XMVAD) + (IZM-XMVAD-AV)
Moeller HPL0211-2007/2008
11/48
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
OrderingWithdrawable units
Pole For use with Rated current = rated uninterrupted current
Part no. suffixOrder number for orders with basic unit
Pricesee price list
Part no.Order number for separate orders
Pricesee price list
Std. pack
Notes
In = IuA
Withdrawable unit
3-pole
IZM...1-...IN...1-...
6308001000
+IZM2307
IZM...1-...IN...1-...
12501600
+IZM2307
IZM...2-...IN...2-...
8001000125016002000
+IZM2257
2500 +IZM2257
3200 +IZM2257
IZM...3-...IN...3-...
4000 +IZM2307
5000 +IZM2307
6300 +IZM2257
4-pole
IZM...1-4-...IN...1-4-...
1000 +IZM2307
IZM...1-4-...IN...1-4-...
1600 +IZM2307
IZM...2-4-...IN...2-4-...
2000 +IZM2257
2500 +IZM2257
3200 +IZM2257
IZM...3-4-...IN...3-4-...
4000 +IZM2307
5000 +IZM2307
6300 +IZM2570
Replacement switch
For withdrawable unit– – +IZM
2257
IZM... -XAV...
1-XAV1033
1-XAV16352-XAV20
72
2-XAV25732-XAV32
74
3-XAV40373-XAV50
393-XAV63
76
1-XAV104421-XAV164
442-XAV204
792-XAV254
802-XAV324
81
3-XAV404463-XAV504
48
3-XAV634
06-XAVE84
IZM1-XAV10230734
1 off Standard: Horizontal connections; versions a Connections for withdrawable unit.A rated operational voltage of 1000 V is possible only when ordering together with the basic unit for 1000 V.When ordering separately, note:• Withdrawable units already contain four control
circuit plugs (X5 – X8) with screw-type terminals.
• Can be combined only with basic units that have been prepared for withdrawable units (basic unit +IZM-XAVE or with IZM...-XUS...-AV conversion kit)
IZM1-XAV16230736
IZM2-XAV20225978
IZM2-XAV25225979
IZM2-XAV32225980
IZM3-XAV40230738
IZM3-XAV50230740
IZM3-XAV63225982
IZM1-XAV104230743
IZM1-XAV164230745
IZM2-XAV204225985
IZM2-XAV254225986
IZM2-XAV324225987
IZM3-XAV404230747
IZM3-XAV504230749
IZM3-XAV634257001
6300 A device: connections always vertical.A rated operational voltage of 1000 V is possible only when ordering together with the basic unit for 1000 V.When ordering separately, note:• Withdrawable units already contain four control
circuit plugs (X5 – X8) with screw-type terminals.
• Can be combined only with basic units that
have been prepared for withdrawable units (basic unit +IZM-XAVE or with IZM...-XUS...-AV conversion kit)1 off Type suffix for basic unit for use in withdrawable unit• For replacements or• when ordering basic unit and withdrawable
unit separatelyThe basic unit is factory-modified (cranks, control sliders, side panels) to allow its insertion in the respective withdrawable unit.
11/49
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rs
to 6
300
A
OrderingWithdrawable units
Pole For use with Part no. suffixOrder number for orders with basic unit
Pricesee price list
Part no.Order number for separate orders
Pricesee price list
Std. pack Notes
Conversion kit
Fixed mounted in withdrawable unit3-pole IZM...1-...
IN...1-...IZM1-XUS-AV256950
1 off Retrospectively converting fixed mounting switches
IZM...2-...IN...2-...IZM...3-...IN...3-...
4-pole IZM...1-4-...IN...1-4-...IZM...2-4-...IN...2-4-..IZM...3-4-IN...3-4-..
Position signalling switches
For withdrawable unit
Module 1 –
Module 2 –
Shutters
3-pole IZM...1-...IN...1-...IZM...2-...IN...2-...IZM...3-...IN...3-...
4-pole IZM...1-4-IN...1-4-..IZM...2-4-IN...2-4-..IZM...3-4-IN...3-4-..
Arcing chamber cover
For withdrawable unit F 690 V3-pole IZM...1-...
IN...1-...IZM...2-...IN...2-...IZM...3-...IN...3-...
4-pole IZM...1-4-IN...1-4-..IZM...2-4-IN...2-4-..IZM...3-4-IN...3-4-..
Coding system
for equipment dependent coding–
IZM...-XUS…, IZM-X…
.....
+IZM23070
+IZM23070
+IZM23066+IZM22580+IZM22581
....
+IZM23066
....
+IZM22580
....
+IZM22581
+IZM23069+IZM23069
+IZM2307....
+IZM2307
....
+IZM2307
....
+IZM2307
Circ
uit-
brea
kfr
om 6
30 A
(cranks, control sliders, side panels) to allow the switch to be used in the respective withdrawable unit.
IZM2-XUS-AV256951
IZM3-XUS-AV256952
IZM1-XUS4-AV256955
IZM2-XUS4-AV256957
IZM3-XUS4-AV256959
-XHIAV18
IZM-XHIAV1232166
1 off Position signalConnected position: 1 changeover contactTest position: 1 changeover contactDisconnected position: 1 changeover contact
-XHIAV29
IZM-XHIAV2232167
1 off Position signalConnected position: 3 changeover contactsTest position: 2 changeover contactsDisconnected position: 1 changeover contact
1-XIKL4
IZM1-XIKL230665
1 off Standard: Lockable with padlocks
2-XIKL8
IZM2-XIKL226007
3-XIKL0
IZM3-XIKL226009
1-XIKL46
IZM1-XIKL4230667
2-XIKL49
IZM2-XIKL4226008
3-XIKL41
IZM3-XIKL4226010
1-XLKA-AV6
IZM1-XLKA-AV230697
1 off
2-XLKA-AV8
IZM2-XLKA-AV230699
3-XLKA-AV00
IZM3-XLKA-AV230701
1-XLKA4-AV02
IZM1-XLKA4-AV230703
2-XLKA4-AV04
IZM2-XLKA4-AV230705
3-XLKA4-AV06
IZM3-XLKA4-AV230707
IZM-XCE225999
1 36 coding variants
11/50Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A11/51
Moeller HPL0211-2007/2008 Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Ordering OrderingConnection systems for fixed mounting Connection systems for fixed mounting
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
For use with Rated current = rated uninterrupted current
Type suffixOrder number for orders with basic unit
Std. pack TypeOrder number for separate orders
Std. pack Notes Notes
In = IuA
Connection type for fixed mounted unit, individual connectorsVertical connection
IZM...1(-4)-...IN...1(-4)-...
1000 +IZM1-XATV10257013
1 off IZM1-XATV10257009
1 off For the 3-pole circuit-breakers, 6 connections are to be ordered and for the 4-pole circuit-breakers, 8 connections are to be ordered
IZM...1(-4)-...IN...1(-4)-...
1600 +IZM1-XATV16230450
IZM1-XATV16230451
(+)IZM1-XATV16 consists of 2 x (+)IZM1-XATV10
IZM...2(-4)-...IN...2(-4)-...
2500 +IZM2-XATV25230877
IZM2-XATV25230878
IZM...2(-4)-...IN...2(-4)-...
3200 +IZM2-XATV32230452
IZM2-XATV32230453
(+)IZM2-XATV32 consists of 2 x (+)IZM2-XATV25
IZM...3(-4)-...IN...3(-4)-...
5000 +IZM3-XATV50230454
IZM3-XATV50230455
(+)IZM3-XATV50 has the same design as the vertical connection supplied as standard with the 6300 A (fixed mounting) devices.
Front connection top (single-hole fitting)When front connections are used, a partition between busbar and arcing space must be fitted on the system side.
IZM...1(-4)-...IN...1(-4)-...
1000 +IZM1-XAT1F10-O230456
1 off IZM1-XAT1F10-O230457
1 off For the 3-pole circuit-breakers, 3 connections are to be ordered and for the 4-pole circuit-breakers, 4 connections are to be ordered
IZM...1(-4)-...IN...1(-4)-...
1600 +IZM1-XAT1F16-O230458
IZM1-XAT1F16-O230459
IZM...2(-4)-...IN...2(-4)-...
2000 +IZM2-XAT1F20-O230460
IZM2-XAT1F20-O230461
IZM...2(-4)-...IN...2(-4)-...
2500 +IZM2-XAT1F25-O230462
IZM2-XAT1F25-O230463
IZM...2(-4)-...IN...2(-4)-...
3200 +IZM2-XAT1F32-O230464
IZM2-XAT1F32-O230465
IZM...3(-4)-...IN...3(-4)-...
4000 +IZM3-XAT1F40-O230466
IZM3-XAT1F40-O230467
Front connection bottom (single-hole fitting)IZM...1(-4)-...IN...1(-4)-...
1000 +IZM1-XAT1F10-U230468
1 off IZM1-XAT1F10-U230469
1 off For the 3-pole circuit-breakers, 3 connections are to be ordered and for the 4-pole circuit-breakers, 4 connections are to be ordered
IZM...1(-4)-...IN...1(-4)-...
1600 +IZM1-XAT1F16-U230470
IZM1-XAT1F16-U230471
IZM...2(-4)-...IN...2(-4)-...
2000 +IZM2-XAT1F20-U230472
IZM2-XAT1F20-U230473
IZM...2(-4)-...IN...2(-4)-...
2500 +IZM2-XAT1F25-U230474
IZM2-XAT1F25-U230475
IZM...2(-4)-...IN...2(-4)-...
3200 +IZM2-XAT1F32-U230476
IZM2-XAT1F32-U230477
IZM...3(-4)-...IN...3(-4)-...
4000 +IZM3-XAT1F40-U230478
IZM3-XAT1F40-U230479
Front connection, top (double-hole fitting according to DIN 43673)When front connections are used, a partition between busbar and arcing space must be fitted on the system side.
IZM...1(-4)-...IN...1(-4)-...
1000 +IZM1-XATF10-O230480
1 off IZM1-XATF10-O230481
1 off For the 3-pole circuit-breakers, 3 connections are to be ordered and for the 4-pole circuit-breakers, 4 connections are to be ordered
IZM...1(-4)-...IN...1(-4)-...
1600 +IZM1-XATF16-O230482
IZM1-XATF16-O230483
IZM...2(-4)-...IN...2(-4)-...
2000 +IZM2-XATF20-O230484
IZM2-XATF20-O230485
IZM...2(-4)-...IN...2(-4)-...
2500 +IZM2-XATF25-O230486
IZM2-XATF25-O230487
IZM...2(-4)-...IN...2(-4)-...
3200 +IZM2-XATF32-O225819
IZM2-XATF32-O226022
IZM...3(-4)-...IN...3(-4)-...
4000 +IZM3-XATF40-O230488
IZM3-XATF40-O230489
Front connection bottom (double-hole fitting according to DIN 43673)IZM...1(-4)-...IN...1(-4)-...
1000 +IZM1-XATF10-U230490
1 off IZM1-XATF10-U230491
1 off For the 3-pole circuit-breakers, 3 connections are to be ordered and for the 4-pole circuit-breakers, 4 connections are to be ordered
IZM...1(-4)-...IN...1(-4)-...
1600 +IZM1-XATF16-U230492
IZM1-XATF16-U230493
IZM...2(-4)-...IN...2(-4)-...
2000 +IZM2-XATF20-U230494
IZM2-XATF20-U230495
IZM...2(-4)-...IN...2(-4)-...
2500 +IZM2-XATF25-U230496
IZM2-XATF25-U230497
IZM...2(-4)-...IN...2(-4)-...
3200 +IZM2-XATF32-U225820
IZM2-XATF32-U226023
IZM...3(-4)-...IN...3(-4)-...
4000 +IZM3-XATF40-U230498
IZM3-XATF40-U230499
IZM...-XAT... IZM...-XAT...
11/52Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A11/53
Moeller HPL0211-2007/2008 Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Ordering OrderingConnection system for withdrawable unit Connection system for withdrawable unit
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Pole For use with Rated current = rated uninterrupted current
Part no. suffixOrder number for orders with basic unit
Std. pack Part no.Order number for separate orders
Std. pack Notes
In = IuA
Connection type for withdrawable unit, individual connectors
Vertical connectionIZM...1(-4)-...IN...1(-4)-...
1000 +IZM1-XATV10-AV230500
1 off IZM1-XATV10-AV230501
1 off For the 3-pole circuit-breakers, 6 connections are to be ordered and for the 4-pole circuit-breakers, 8 connections are to be ordered
IZM...1(-4)-...IN...1(-4)-...
1600 +IZM1-XATV16-AV230502
IZM1-XATV16-AV230503
IZM...2(-4)-...IN...2(-4)-...
2000 +IZM2-XATV20-AV230504
IZM2-XATV20-AV230505
IZM...2(-4)-...IN...2(-4)-...
2500 +IZM2-XATV25-AV230506
IZM2-XATV25-AV230507
IZM...2(-4)-...IN...2(-4)-...
3200 +IZM2-XATV32-AV230508
IZM2-XATV32-AV230509
IZM...3(-4)-...IN...3(-4)-...
5000 +IZM3-XATV50-AV230510
IZM3-XATV50-AV230511
Front connection (single-hole fitting)IZM...1(-4)-...IN...1(-4)-...
1000 +IZM1-XAT1F10-AV230514
1 off IZM1-XAT1F10-AV230515
1 off For the 3-pole switches order six connections and for the 4-pole switches order eight connections.When ordering front connectors for withdrawable units separately, additional insulators are required, which must be ordered separately. When ordering with the basic unit (type suffix), the insulators are included as standard.
IZM...1(-4)-...IN...1(-4)-...
1600 +IZM1-XAT1F16-AV230516
IZM1-XAT1F16-AV230517
IZM...2(-4)-...IN...2(-4)-...
2000 +IZM2-XAT1F20-AV230518
IZM2-XAT1F20-AV230519
IZM...2(-4)-...IN...2(-4)-...
2500 +IZM2-XAT1F25-AV230520
IZM2-XAT1F25-AV230521
IZM...2(-4)-...IN...2(-4)-...
3200 +IZM2-XAT1F32-AV230522
IZM2-XAT1F32-AV230523
IZM...3(-4)-...IN...3(-4)-...
4000 +IZM3-XAT1F40-AV230524
IZM3-XAT1F40-AV230525
Front connection (double-hole fitting according to DIN 43673)IZM...1(-4)-...IN...1(-4)-...
1000 +IZM1-XATF10-AV230526
1 off IZM1-XATF10-AV230527
1 off For the 3-pole switches order six connections and for the 4-pole switches order eight connections.When ordering front connectors for withdrawable units separately, additional insulators are required, which must be ordered separately. When ordering with the basic unit (type suffix), the insulators are included as standard.
IZM...1(-4)-...IN...1(-4)-...
1600 +IZM1-XATF16-AV230528
IZM1-XATF16-AV230529
IZM...2(-4)-...IN...2(-4)-...
2000 +IZM2-XATF20-AV230530
IZM2-XATF20-AV230531
IZM...2(-4)-...IN...2(-4)-...
2500 +IZM2-XATF25-AV230532
IZM2-XATF25-AV230533
IZM...2(-4)-...IN...2(-4)-...
3200 +IZM2-XATF32-AV230534
IZM2-XATF32-AV230535
IZM...3(-4)-...IN...3(-4)-...
4000 +IZM3-XATF40-AV230536
IZM3-XATF40-AV230537
Insulator for front connections3-pole IZM...1-...
IN...1-...– IZM1-XATFS
2569271 off For withdrawable units, the insulators for installing the front connections are required.
When ordering the front connections separately, you must order one insulator for each connection side (incoming and outgoing side).IZM...2-...
IN...2-...– IZM2-XATFS
256928
IZM...3-...IN...3-...
– IZM3-XATFS256930
4-pole IZM...1-4-...IN...1-4-...
– IZM1-XATFS4256938
IZM...2-4-...IN...2-4-...
– IZM2-XATFS4256940
IZM...3-4-...IN...3-4-...
– IZM3-XATFS4256942
Flange connectionIZM...1(-4)-...IN...1(-4)-...
1000 +IZM1-XATA10-AV230817
1 off IZM1-XATA10-AV230818
1 off For the 3-pole circuit-breakers, 6 connections are to be ordered and for the 4-pole circuit-breakers, 8 connections are to be ordered
IZM...1(-4)-...IN...1(-4)-...
1600 +IZM1-XATA16-AV230819
IZM1-XATA16-AV230820
IZM...2(-4)-...IN...2(-4)-...
2000 +IZM2-XATA20-AV230821
IZM2-XATA20-AV230822
IZM...2(-4)-...IN...2(-4)-...
2500 +IZM2-XATA25-AV230823
IZM2-XATA25-AV230824
IZM...2(-4)-...IN...2(-4)-...
3200 +IZM2-XATA32-AV230825
IZM2-XATA32-AV230826
IZM...3(-4)-...IN...3(-4)-...
4000 +IZM3-XATA40-AV230827
IZM3-XATA40-AV230828
IZM...-XAT... IZM...-XAT...
Moeller HPL0211-2007/2008
11/54
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Engineering415 V AC selectivity table
Selectivity between circuit-breakers enables separate shut-down of faulty system sections. Selectivity (discrimination) exists between incom-ing breaker 1 and outgoing breaker 2 if, only outgoing breaker 2 trips at position 2 during a short-circuit. System sections 3 and 4 continue to be operational.
Selection:Provided that the short-circuit current does not exceed those values specified (Icceff in kA). These details represent the limits of selectivity. Both circuit-breakers will switch off with higher short-circuit currents. On IZM circuit-breakers with V, U, D releases, the delay time tsd must be at least 100 ms longer than the delay time of the next downstream levels (2, 3, 4).
In:
Iu:
Ii:
Rated current
Rated uninterrupted current
Setting: non-delayed short-circuit releases
1
2 3 4
Part no. IZM…1-A…incoming c
In = Iu [A] 630Ii [A] 5040Icu[kA] 50 65
Outgoing circuit-breaker
Iu [A] Icu[kA] B NNZM...1-A... 40 25(50) 5 5
50 25(50) 5 563 25(50) 5 580 25(50) 5 5100 25(50) 5 5125 25(50) 5 5
NZM...2-A... 40 100(150) 5 550 100(150) 5 563 100(150) 5 580 100(150) 5 5100 100(150) 5 5125 25...150 5 5160 25...150 5 5200 25...150 5 5250 25...150 5 5
NZM...1-M... 40 25(50) 5 550 25(50) 5 563 25(50) 5 580 25(50) 5 5
NZM...2-M 125 25...150 5 5160 25...150 5 5200 25...150 5 5
NZM...2-VE... 100 50...150 5 5160 50...150 5 5250 50...150 5 5
NZM...3-...E... 250 50...150 5 5400 50...150 5 5630 50...150 5 5
NZM...4-...E... 630 50...100 5 5800 50...100 5 51000 50...100 5 51250 50...100 5 51600 50...100 5 5
Notes T: Full selec
IZM...1-A..., IZM...1-V...
ircuit-breakers w
800 106400 8050 65 50
B N B6 6 86 6 86 6 86 6 86 6 86 6 8
6 6 86 6 86 6 86 6 86 6 86 6 86 6 86 6 86 6 8
6 6 86 6 86 6 86 6 8
6 6 86 6 86 6 8
6 6 86 6 86 6 8
6 6 86 6 86 6 8
6 6 86 6 86 6 86 6 86 6 8
tivity
ith standard trip release (A)IZM…1-V… incoming circuit-breakers with selectively-operating release (V)
00 1250 1600 630 800 1000 1250 160000 10000 12800 12600 16000 20000 25000 32000
65 50 65 50 65 50 65 50 65 50 65 50 65 50 65
Prospective short-circuit current (kA)
N B N B N B N B N B N B N B N8 12 12 16 16 16 16 T(35) T(35) T T T T T T8 12 12 16 16 16 16 T(35) T(35) T T T T T T8 12 12 16 16 16 16 T(35) T(35) T T T T T T8 12 12 16 16 16 16 T(35) T(35) T T T T T T8 12 12 16 16 16 16 T(35) T(35) T T T T T T8 12 12 16 16 16 16 T(35) T(35) T T T T T T
8 12 12 20 20 20 20 40 40 T T T T T T8 12 12 20 20 20 20 40 40 T T T T T T8 12 12 20 20 20 20 40 40 T T T T T T8 12 12 20 20 20 20 40 40 T T T T T T8 12 12 20 20 20 20 40 40 T T T T T T8 12 12 20 20 20 20 T(40) T(40) T T T T T T8 12 12 20 20 20 20 T(40) T(40) T T T T T T8 12 12 20 20 20 20 T(40) T(40) T T T T T T8 12 12 20 20 20 20 T(40) T(40) T T T T T T
8 12 12 16 16 16 16 T(35) T(35) T T T T T T8 12 12 16 16 16 16 T(35) T(35) T T T T T T8 12 12 16 16 16 16 T(35) T(35) T T T T T T8 12 12 16 16 16 16 T(35) T(35) T T T T T T
8 12 12 20 20 20 20 T(40) T(40) T T T T T T8 12 12 20 20 20 20 T(40) T(40) T T T T T T8 12 12 20 20 20 20 T(40) T(40) T T T T T T
8 12 12 20 20 20 20 16 16 T T T T T T8 12 12 20 20 20 20 16 16 T T T T T T8 12 12 20 20 20 20 16 16 T T T T T T
8 12 12 12 12 12 12 16 16 20 20 30 30 T T8 12 12 12 12 12 12 16 16 20 20 30 30 T T8 12 12 12 12 12 12 16 16 20 20 30 30 T T
8 12 12 12 12 12 12 16 16 20 20 30 30 32 328 12 12 12 12 12 12 16 16 20 20 30 30 32 328 12 12 12 12 12 12 16 16 20 20 30 30 32 328 12 12 12 12 12 12 16 16 20 20 30 30 32 328 12 12 12 12 12 12 16 16 20 20 30 30 32 32
11/55
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rs
to 6
300
A
Engineering415 V AC selectivity table
Selectivity between circuit-breakers enables separate shut-down of faulty system sections. Selectivity (discrimination) exists between incom-ing breaker 1 and outgoing breaker 2 if, only outgoing breaker 2 trips at position 2 during a short-circuit. System sections 3 and 4 continue to be operational.
Selection:Provided that the short-circuit current does not exceed those values specified (Icceff in kA). These details represent the limits of selectivity. Both circuit-breakers will switch off with higher short-circuit currents.On IZM circuit-breakers with V, U, D releases, the delay time tsd must be at least 100 ms longer than the delay time of the next downstream levels (2, 3, 4).
In:
Iu:
Ii:
Rated current
Rated uninterrupted current
Setting: non-delayed short-circuit releases
1
2 3 4
Part no. IZM…1-U… Incoming circuit-breake
In = Iu [A] 630 800Ii [kA] 40 52 40 52Icu[kA] 50 65
OFF/ONOutgoing circuit-breaker
Iu [A] Icu[kA] B NNZM...1-A... 40 25(50) T T
50 25(50) T T63 25(50) T T80 25(50) T T100 25(50) T T125 25(50) T T
NZM...2-A... 40 100(150) T T50 100(150) T T63 100(150) T T80 100(150) T T100 100(150) T T125 25...100 T T160 25...100 T T200 25...100 T T250 25...100 T T
NZM...1-M... 40 25(50) T T50 25(50) T T63 25(50) T T80 25(50) T T100 25(50) T T
NZM...2-M... 125 25...150 T T160 25...150 T T200 25...150 T T
NZM...2-VE... 100 50...150 T T160 50...150 T T250 50...150 T T
NZM...3-...E... 250 50...150 T T400 50...150 T T630 50...150 T T
NZM...4-...E... 630 50(100) T/40 T/5800 50(100) T/40 T/51000 50(100) T/40 T/51250 50(100) T/40 T/51600 50(100) T/40 T/5
Notes T: Full se
IZM...1-U..., IZM...1-D...
50 65OFF/ON
B NT TT TT TT TT TT T
T TT TT TT TT TT TT TT TT T
T TT TT TT TT T
T TT TT T
T TT TT T
T TT TT T
2 T/40 T/522 T/40 T/522 T/40 T/522 T/40 T/522 T/40 T/52
lectivity
Circ
uit-
brea
kfr
om 6
30 A
r with universal trip-release (U)IZM…1-D… incoming circuit-breaker with digital trip-relaese (D)
1000 1250 1600 630 800 1000 1250 160040 52 40 52 40 52 40 52 40 52 40 52 40 52 40 5250 65 50 65 50 65 50 65 50 65 50 65 50 65 50 65OFF/ON OFF/ON OFF/ON
Prospective short-circuit current (kA)
B N B N B N B N B N B N B N B NT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T T
T T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T T
T T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T T
T T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T T
T T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T T
T T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T T
T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52 T/40 T/52
Moeller HPL0211-2007/2008
11/56
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Engineering415 V AC selectivity table
Selectivity between circuit-breakers enables separate shut-down of faulty system sections. Selectivity (discrimination) exists between incom-ing breaker 1 and outgoing breaker 2 if, only outgoing breaker 2 trips at position 2 during a short-circuit. System sections 3 and 4 continue to be operational.
Selection:Provided that the short-circuit current does not exceed those values specified (Icceff in kA). These details represent the limits of selectivity. Both circuit-breakers will switch off with higher short-circuit currents.
In:
Iu:
Ii:
Rated current
Rated uninterrupted current
Setting: non-delayed short-circuit releases
1
2 3 4
Part no. IZM…2-Aincoming
In = Iu [A] 800Ii [A] 6400Icu[kA] 55 80
Outgoing circuit-breaker
Iu [A] Icu[kA] B NNZM...1-A... 40 25(50) 6 6
50 25(50) 6 663 25(50) 6 680 25(50) 6 6100 25(50) 6 6125 25(50) 6 6
NZM...2-A... 40 100(150) 6 650 100(150) 6 663 100(150) 6 680 100(150) 6 6100 100(150) 6 6125 25...150 6 6160 25...150 6 6200 25...150 6 6250 25...150 6 6
NZM...1-M... 40 25(50) 6 650 25(50) 6 663 25(50) 6 680 25(50) 6 6100 25(50) 6 6
NZM...2-M... 125 25...150 6 6160 25...150 6 6200 25...150 6 6
NZM...2-VE... 100 50...150 6 6160 50...150 6 6250 50...150 6 6
NZM...3-E... 250 50...150 6 6400 50...150 6 6630 50...150 6 6
NZM...4-...E... 630 50(100) 6 6800 50(100) 6 61000 50(100) 6 61250 50(100) 6 61600 50(100) 6 6
Notes T: Full sel
IZM...2-A...
… circuit-breaker
10008000
100 55 80
H B N6 8 86 8 86 8 86 8 86 8 86 8 8
6 8 86 8 86 8 86 8 86 8 86 8 86 8 86 8 86 8 8
6 8 86 8 86 8 86 8 86 8 8
6 8 86 8 86 8 8
6 8 86 8 86 8 8
6 8 86 8 86 8 8
6 8 8
6 8 86 8 86 8 86 8 8ectivity
with standard trip-releaes (A) Ii = 8 x In1250 1600 2000 2500 320010000 12800 16000 20000 25600
100 55 80 100 55 80 100 55 80 100 55 80 100 55 80 100Prospective short-circuit current (kA)
H B N H B N H B N H B N H B N H8 10 10 10 16 16 16 T(25) T(25) T(25) T(42) T(42) T(42) T T T8 10 10 10 16 16 16 T(25) T(25) T(25) T(42) T(42) T(42) T T T8 10 10 10 16 16 16 T(25) T(25) T(25) T(42) T(42) T(42) T T T8 10 10 10 16 16 16 T(25) T(25) T(25) T(42) T(42) T(42) T T T8 10 10 10 16 16 16 T(25) T(25) T(25) T(42) T(42) T(42) T T T8 10 10 10 16 16 16 T(25) T(25) T(25) T(42) T(42) T(42) T T T
8 10 10 10 20 20 20 30 30 30 55 65 65 T T T8 10 10 10 20 20 20 30 30 30 55 65 65 T T T8 10 10 10 20 20 20 30 30 30 55 65 65 T T T8 10 10 10 20 20 20 30 30 30 55 65 65 T T T8 10 10 10 20 20 20 30 30 30 55 65 65 T T T8 10 10 10 20 20 20 T(30) T(30) T(30) T(55) T(65) T(65) T T T8 10 10 10 20 20 20 T(30) T(30) T(30) T(55) T(65) T(65) T T T8 10 10 10 20 20 20 T(30) T(30) T(30) T(55) T(65) T(65) T T T8 10 10 10 20 20 20 T(30) T(30) T(30) T(55) T(65) T(65) T T T
8 10 10 10 16 16 16 T(25) T(25) T(25) T(42) T(42) T(42) T T T8 10 10 10 16 16 16 T(25) T(25) T(25) T(42) T(42) T(42) T T T8 10 10 10 16 16 16 T(25) T(25) T(25) T(42) T(42) T(42) T T T8 10 10 10 16 16 16 T(25) T(25) T(25) T(42) T(42) T(42) T T T8 10 10 10 16 16 16 T(25) T(25) T(25) T(42) T(42) T(42) T T T
8 10 10 10 20 20 20 T(30) T(30) T(30) T(55) T(65) T(65) T T T8 10 10 10 20 20 20 T(30) T(30) T(30) T(55) T(65) T(65) T T T8 10 10 10 20 20 20 T(30) T(30) T(30) T(55) T(65) T(65) T T T
8 10 10 10 20 20 20 30 30 30 T(55) T(65) T(65) T T T8 10 10 10 20 20 20 30 30 30 T(55) T(65) T(65) T T T8 10 10 10 20 20 20 30 30 30 T(55) T(65) T(65) T T T
8 10 10 10 12 12 12 16 16 16 20 20 20 30 30 308 10 10 10 12 12 12 16 16 16 20 20 20 30 30 308 10 10 10 12 12 12 16 16 16 20 20 20 30 30 30
8 10 10 10 12 12 12 16 16 16 20 20 20 25 25 258 10 10 10 12 12 12 16 16 16 20 20 20 25 25 258 10 10 10 12 12 12 16 16 16 20 20 20 25 25 258 10 10 10 12 12 12 16 16 16 20 20 20 25 25 258 10 10 10 12 12 12 16 16 16 20 20 20 25 25 25
11/57
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rs
to 6
300
A
Engineering415 V AC selectivity table
Selectivity between circuit-breakers enables separate shut-down of faulty system sections. Selectivity (discrimination) exists between incom-ing breaker 1 and outgoing breaker 2 if, only outgoing breaker 2 trips at position 2 during a short-circuit. System sections 3 and 4 continue to be operational.
Selection:Provided that the short-circuit current does not exceed those values specified (Icc eff in kA). These details represent the lim-its of selectivity. Both circuit-breakers will switch off with higher short-circuit currents. On IZM circuit-breakers with V, U, D releases, the delay time tsd must be at least 100 ms longer than the delay time of the next downstream levels (2, 3, 4).
In:
Iu:
Ii:
Rated current
Rated uninterrupted current
Setting: non-delayed short-circuit releases
1
2 3 4
Part no. IZM…2(3)-V… incoming circuit-breaker with selectively
In = Iu [A] 800 1000 1250Ii [A] 16000 20000 25000Icu[kA] 55 80 100 55 80Outgoing cir-cuit-breakerIu [A] Icu[kA] B N H B NNZM...1-A...40 25(50) T(35) T(35) T(35) T T50 25(50) T(35) T(35) T(35) T T63 25(50) T(35) T(35) T(35) T T80 25(50) T(35) T(35) T(35) T T100 25(50) T(35) T(35) T(35) T T125 25(50) T(35) T(35) T(35) T T
NZM...2-A40 100(150) 40 40 40 T T50 100(150) 40 40 40 T T63 100(150) 40 40 40 T T80 100(150) 40 40 40 T T100 100(150) 40 40 40 T T125 25...150 T(40) T(40) T(40) T T160 25...150 T(40) T(40) T(40) T T200 25...150 T(40) T(40) T(40) T T250 25...150 T(40) T(40) T(40) T T
NZM...1-M...40 25(50) T(35) T(35) T(35) T T50 25(50) T(35) T(35) T(35) T T63 25(50) T(35) T(35) T(35) T T80 25(50) T(35) T(35) T(35) T T100 25(50) T(35) T(35) T(35) T T
NZM...2-M125 25...150 T(40) T(40) T(40) T T160 25...150 T(40) T(40) T(40) T T200 25...150 T(40) T(40) T(40) T T
NZM...2-E100 50...150 16 16 16 T T160 50...150 16 16 16 T T250 50...150 16 16 16 T T
NZM...3-...E...250 50...150 16 16 16 20 20400 50...150 16 16 16 20 20630 50...150 16 16 16 20 20
NZM...4-...E630 50...100 16 16 16 20 20800 50...100 16 16 16 20 201000 50...100 16 16 16 20 201250 50...100 16 16 16 20 201600 50...100 16 16 16 20 20
Notes T: Full selectivity
IZM...2-V..., IZM…3…-V
100 55 8
H B N
T T TT T TT T TT T TT T TT T T
T T TT T TT T TT T TT T TT T TT T TT T TT T T
T T TT T TT T TT T TT T T
T T TT T TT T T
T T TT T TT T T
20 30 320 30 320 30 3
20 3020 3020 3020 3020 30
Circ
uit-
brea
kfr
om 6
30 A
-operating trip-release (V) Iimax = 50 kA1600 2000 2500 3200 4000 5000 630032000 40000 50000 50000 50000
0 100 55 80 100 55 80 100 55 80 100 55 80 100 100 100 100Prospective short-circuit current (kA)
H B N H B N H B N H B N H B N H
T T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T T
T T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T T
T T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T T
T T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T T
T T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T T
0 30 T T T T T T T T T T T T T T T0 30 T T T T T T T T T T T T T T T0 30 T T T T T T T T T T T T T T T
30 30 32 32 32 40 40 40 T(50) T(50) T(50) T(50) T(50) T(50) T(50) T(50) T(50)30 30 32 32 32 40 40 40 T(50) T(50) T(50) T(50) T(50) T(50) T(50) T(50) T(50)30 30 32 32 32 40 40 40 T(50) T(50) T(50) T(50) T(50) T(50) T(50) T(50) T(50)30 30 32 32 32 40 40 40 T(50) T(50) T(50) T(50) T(50) T(50) T(50) T(50) T(50)30 30 32 32 32 40 40 40 T(50) T(50) T(50) T(50) T(50) T(50) T(50) T(50) T(50)
Moeller HPL0211-2007/2008
11/58
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Engineering415 V AC selectivity table
Selectivity between circuit-breakers enables separate shut-down of faulty system sections. Selectivity (discrimination) exists between incom-ing breaker 1 and outgoing breaker 2 if, only outgoing breaker 2 trips at position 2 during a short-circuit. System sections 3 and 4 continue to be operational.
Selection:Provided that the short-circuit current does not exceed those values specified (Icc eff in kA). These details represent the lim-its of selectivity. Both circuit-breakers will switch off with higher short-circuit currents. On IZM circuit-breakers with V, U, D releases, the delay time tsd must be at least 100 ms longer than the delay time of the next downstream levels (2, 3, 4).
In:
Iu:
Ii:
Rated current
Rated uninterrupted current
Setting: non-delayed short-circuit releases
1
2 3 4
Part no. IZM…2(3)-U… incoming circuit-breaker
In = Iu [A] 800 1000Ii [kA] 44 64 80 44 64Icu[kA] 55 80 100 55 80Outgoing cir-cuit-breakerIu [A] Icu[kA] B N H B N
OFF/ON OFF/ONNZM...1-A...40 25(25) T T T T T50 25(50) T T T T T63 25(50) T T T T T80 25(50) T T T T T100 25(50) T T T T T125 25(50) T T T T T
NZM...2-A40 100(150) T T T T T50 100(150) T T T T T63 100(150) T T T T T80 100(150) T T T T T100 100(150) T T T T T125 25...150 T T T T T160 25...150 T T T T T200 25...150 T T T T T250 25...150 T T T T T
NZM...1-M40 25(50) T T T T T50 25(50) T T T T T63 25(50) T T T T T80 25(50) T T T T T100 25(50) T T T T T
NZM...2-M125 25...150 T T T T T160 25...150 T T T T T250 25...150 T T T T T
NZM...2-E100 50...150 T T T T T160 50...150 T T T T T250 50...150 T T T T T
NZM...3-...E...250 50...150 45 T(64) T(80) 45 T(6400 50...150 45 T(64) T(80) 45 T(6630 50...150 45 T(64) T(80) 45 T(6
NZM...4-...E630 50(100) 45 T(64) T(80) 45 T(6800 50(100) 45 T(64) T(80) 45 T(61000 50(100) 45 T(64) T(80) 45 T(61250 50(100) 45 T(64) T(80) 45 T(61600 50(100) 45 T(64) T(80) 45 T(6
Notes T: Full selectivity
IZM...2-U..., IZM…3-U…
with universal t1250
80 44 6100 55 8
H B NOFF/O
T T TT T TT T TT T TT T TT T T
T T TT T TT T TT T TT T TT T TT T TT T TT T T
T T TT T TT T TT T TT T T
T T TT T TT T T
T T T
T TT T4) T(80) 454) T(80) 454) T(80) 45
4) T(80) 454) T(80) 454) T(80) 454) T(80) 454) T(80) 45
rip-release (U) Ii = 0.8 x Icu(= 0.8 x Ics)1600 2000 2500 3200 4000 5000 6300
4 80 44 64 80 44 64 80 44 64 80 44 64 80 800 100 55 80 100 55 80 100 55 80 100 55 80 100 100 100 100
Prospective short-circuit current (kA)
H B N H B N H B N H B N H B N HN OFF/ON OFF/ON OFF/ON OFF/ON OFF/ON
T T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T T
T T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T T
T T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T T
T T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T T
T T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T T T
T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) T(80) T(80) T(80)T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) T(80) T(80) T(80)T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) T(80) T(80) T(80)
T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) T(80) T(80) T(80)T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) T(80) T(80) T(80)T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) T(80) T(80) T(80)T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) T(80) T(80) T(80)T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80) T(80) T(80) T(80)
11/59
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rs
to 6
300
A
Engineering415 V AC selectivity table
Selectivity between circuit-breakers enables separate shut-down of faulty system sections. Selectivity (discrimination) exists between incom-ing breaker 1 and outgoing breaker 2 if, only outgoing breaker 2 trips at position 2 during a short-circuit. System sections 3 and 4 continue to be operational.
Selection:Provided that the short-circuit current does not exceed those values specified (Icc eff in kA). These details represent the lim-its of selectivity. Both circuit-breakers will switch off with higher short-circuit currents. On IZM circuit-breakers with V, U, D releases, the delay time tsd must be at least 100 ms longer than the delay time of the next downstream levels (2, 3, 4).
In:
Iu:
Ii:
Rated current
Rated uninterrupted current
Setting: non-delayed short-circuit releases
1
2 3 4
Part no. IZM…2-D… incoming circu
In = Iu [A] 800Ii [A] 44000 64000Icu[kA]
Outgoing circuit-breaker
Iu [A] Icu[kA]NZM...1-A... 40 25(50)
50 25(50)63 25(50)80 25(50)100 25(50)125 25(50)
NZM...2-A 40 100(150)50 100(150)63 100(150)80 100(150)100 100(150)125 25...150160 25...150200 25...150250 25...150
NZM...1-M... 40 25(50)50 25(50)63 25(50)80 25(50)100 25(50)
NZM...2-M 125 25...150160 25...150200 25...150
NZM...2-E 100 50...150160 50...150250 50...150
NZM...3-...E... 250 50...150400 50...150630 50...150
NZM4-...E 630 50(100)800 50(100)1000 50(100)1250 50(100)1600 50(100)
Notes
IZM...2-D...
55 80
B NT TT TT TT TT TT T
T TT TT TT TT TT TT T
T T
T TT TT TT TT T
T TT TT T
T TT TT T
T TT TT T
45 T(64)45 T(64)45 T(64)45 T(64)45 T(64)
T: Full selectivity
Circ
uit-
brea
kfr
om 6
30 A
it-breake with digital trip-release (D) Ii = 0.8 x Icu = 0.8 x Ics 1000 1250 1600
80000 44000 64000 80000 44000 64000 80000 44000 64000 80000100 55 80 100 55 80 100 55 80 100
Prospective short-circuit current (kA)
H B N H B N H B N HT T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T T
T T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T T
T T T T T T T T T T
T T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T T
T T T T T T T T T TT T T T T T T T T TT T T T T T T T T T
T T T T T T T T T TT T T T T T T T T TT T T T T T T T T T
T T T T T T T T T TT T T T T T T T T TT T T T T T T T T T
T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80)T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80)T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80)T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80)T(80) 45 T(64) T(80) 45 T(64) T(80) 45 T(64) T(80)
Moeller HPL0211-2007/2008
11/60
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Engineering415 V AC selectivity table
Selectivity between circuit-breakers enables separate shut-down of faulty system sections. Selectivity (discrimination) exists between incom-ing breaker 1 and outgoing breaker 2 if, only outgoing breaker 2 trips at position 2 during a short-circuit. System sections 3 and 4 continue to be operational.
Selection:Provided that the short-circuit current does not exceed those values specified (Icc eff in kA). These details represent the lim-its of selectivity. Both circuit-breakers will switch off with higher short-circuit currents. On IZM circuit-breakers with V, U, D releases, the delay time tsd must be at least 100 ms longer than the delay time of the next downstream levels (2, 3, 4).
In:
Iu:
Ii:
Rated current
Rated uninterrupted current
Setting: non-delayed short-circuit releases
1
2 3 4
Part no.
In = Iu [A]Ii [A]Icu [kA]
Outgoing circuit-breaker
Iu [A] Icu[kA]NZM...1-A... 40 25(50)
50 25(50)63 25(50)80 25(50)100 25(50)125 25(50)
NZM...2-A 40 100(150)50 100(150)63 100(150)80 100(150)100 100(150)125 25...150160 25...150200 25...150250 25...150
NZM...1-M... 40 25(50)50 25(50)63 25(50)80 25(50)100 25(50)
NZM...2-M... 125 25...150160 25...150250 25...150
NZM....2-E 100 50...150160 50...150250 50...150
NZM...3-...E... 250 50...150400 50...150630 50...150
NZM...4-...E 630 50(100)800 50(100)1000 50(100)1250 50(100)1600 50(100)
Notes
IZM...2-D..., IZM…3-D…
IZM…2(3)-D… incoming circu200044000 6400055 80
B NT TT TT TT TT TT T
T TT TT TT TT TT TT TT TT T
T TT TT TT TT T
T TT TT T
T TT TT T
T TT TT T
45 T(64)
45 T(64)45 T(64)45 T(64)45 T(64)T: Full selectivi
it-breaker with digital trip-release (D) Ii = 0.8 x Icu = 0.8 x Ics
2500 3200 4000 5000 630080000 44000 64000 80000 44000 64000 80000 80000 80000 80000100 55 80 100 55 80 100 100 100 100
Prospective short-circuit current (kA)
H B N H B N H B N HT T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T T
T T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T T
T T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T TT T T T T T T T T T
T T T T T T T T T TT T T T T T T T T TT T T T T T T T T T
T T T T T T T T T TT T T T T T T T T TT T T T T T T T T T
T T T T T T T T T TT T T T T T T T T TT T T T T T T T T T
T(80) 45 T(64) T(80) 45 T(64) T(80) T(80) T(80) T(80)T(80) 45 T(64) T(80) 45 T(64) T(80) T(80) T(80) T(80)T(80) 45 T(64) T(80) 45 T(64) T(80) T(80) T(80) T(80)T(80) 45 T(64) T(80) 45 T(64) T(80) T(80) T(80) T(80)T(80) 45 T(64) T(80) 45 T(64) T(80) T(80) T(80) T(80)
ty
11/61
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rs
to 6
300
A
EngineeringTripping characteristics for circuit-breakers
Release for protection of systemsL-, I-trip
The following characteristics each demonstrate the largest and smallest setting in the respective protective area. In order to receive the complete tripping characteristic, the respective characteristic sections have been brought together.
The characteristic curves indicate the behaviour of the overcurrent release when it has been activated by one of the currents flowing before the trip. If the overcurrent trip occurs directly after switch on and if the overcurrent release is not activated for this reason, the opening delay may extend by up to ms
Release for selectively-opening circuit-bL-, S, I-tripN trip with option + IZM-XTG trip with option + IZM-XTEarth-fault releaseA) IZM…1-…: 100 … 1200 AIZM…2-…: 100 … 1200 AIZM…3-…: 400 … 1200 A
10000
1000
100
10
1
0.1
0.1 10.01
Ir min.
Ii min. Ii ma
0.5 – 1.0 x In
2 –
Ir max.
t [s]
10000
1000
100
10
1
0.1
0.1 10.01
t [s]
Ir min.
Isd min.
0.4 – 1.0 x In
1.25
Ir max.
IN
IZM…-A…, IZM…-V…
reakers
10
8 x In
Is– 12 x In
0.1 – 0.4 s
10
Circ
uit-
brea
kfr
om 6
30 A
depending on the level of the overcurrent. In order to determine the total opening delay of the switch, about 15 ms are to be added to the shown opening delays for the duration of the arc.
The curves shown apply for an ambient temperature on the switch of –5 … +55 °C. The release can be operated at ambient temperatures from –20 … +70 °C (with LCD display up to 55 °C). An extended tolerance band range can apply with these temperatures.
L = current dependent delayed overload releaseS = short-time delayed short-circuit releaseI = non-delayed short-circuit releaseN = neutral pole overload releaseG = earth-fault release
100
x.
I / In
Tolerances with the setting currentsL: trip between 1.05 and 1.2 x IrS: –0% +20%I: –0% +20%G: –0% +20%
Tolerances with the trip timesL: –20% +0%S: –0 ms +60 msI: < 50 msG: –0 ms +60 ms
d max.
tsd max.
tsd min.
Ii f 20 x lnIi max. 50 kA
100I / In
Moeller HPL0211-2007/2008
11/62
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rsfr
om 6
30 A
to
6300
AEngineeringTripping characteristics for circuit-breakers
Earth-fault releaseG trip with option + IZM-XT
The following characteristics each demonstrate the largest and smallest setting in the respective protective area. In order to receive the complete tripping characteristic, the respective characteristic sections have been brought together.
The characteristic curves indicate the behaviour of the overcurrent release when it has been activated by one of the currents flowing before the trip. If the overcurrent trip occurs directly after switch on and if the overcurrent release is not activated for this reason, the opening delay may extend by up to ms
A) IZM…1-…: 100 … 1200 AIZM…2-…: 100 … 1200 AIZM…3-…: 400 … 1200 A
Release for universal protectionIZM...-U...IZM...-D...L-trip
10000
1000
100
10
1
0.1
0.1 10000.01
Ig min.
100 – 1200 A1)
0.1
Ig max.
t [s]
10000
1000
100
10
1
0.1
0.1 10.01
0.4 – 1.0x In
Ir
t [s]
IZM…-V…,IZM…-U…, IZM…-D…
10000
tg m
tg m – 0.5 s
10
I4t = const.
I2t =
depending on the level of the overcurrent. In order to determine the total opening delay of the switch, about 15 ms are to be added to the shown opening delays for the duration of the arc.
The curves shown apply for an ambient temperature on the switch of –5 … +55 °C. The release can be operated at ambient temperatures from –20 … +70 °C (with LCD display up to 55 °C). An extended tolerance band range can apply with these temperatures.
L = current dependent delayed overload releaseS = short-time delayed short-circuit releaseI = non-delayed short-circuit releaseN = neutral pole overload releaseG = earth-fault release
100000
in.
ax.
I [A]
Tolerances with the setting currentsL: trip between 1.05 and 1.2 x IrS: –0% +20%I: –0% +20%G: –0% +20%
Tolerances with the trip timesL: –20% +0%S: –0 ms +60 msI: < 50 msG: –0 ms +60 ms
100
2 – 30 str
const.
I / In
11/63
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rsto
630
0 A
EngineeringTripping characteristics
Release for universal protection
S-trip
The following characteristics each demonstrate the largest and smallest setting in the respective protective area. In order to receive the complete tripping characteristic, the respective characteristic sections have been brought together.
The characteristic curves indicate the behaviour of the overcurrent release when it has been activated by one of the currents flowing before the trip. If the overcurrent trip occurs directly after switch on and if the overcurrent release is
The characteristic curves apply for a circuit-bfault protection module
Release for universal protectionIZM...-U...IZM...-D...
I-trip
10000
1000
100
10
1
0.1
0.1 10.01
1.25 – 12 x In
Isd
I2tsd = const.
t [s]
10000
1000
1.5 x
t [s]
100
10
1
0.1
0.1 10.01
IZM...-U..., IZM...-D...
reaker IZMH2…,
10
Ii
In – 0.8 x Ics
I / In
10
Circ
uit-
brea
kfr
om 6
30 A
not activated for this reason, the opening delay may extend by up to ms depending on the level of the overcurrent. In order to determine the total opening delay of the switch, about 15 ms are to be added to the shown opening delays for the duration of the arc.
The curves shown apply for an ambient temperature on the switch of –5 … +55 °C. The release can be operated at ambient temperatures from –20 … +70 °C (with LCD display up to 55 °C). An extended tolerance band range can apply with these temperatures.
440 V with earth-
100
I2tsd = const.
tsd = const.0.02 – 0.4 s
0.1 – 0.4 s
I / In
Tolerances with the setting currentsL: trip between 1.05 and 1.2 x IrS: –0% +20%I: –0% +20%G: –0% +20%
Tolerances with the trip timesL: –20% +0%S: –0 ms +60 msI: < 50 msG: –0 ms +60 ms
kA100
Moeller HPL0211-2007/2008
11/64
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rsfr
om 6
30 A
to
6300
AEngineeringTripping characteristics
Earth-fault releaseIZM...-U...IZM...-D...G trip with option (+)IZMU-XT(A)
The following characteristics each demonstrate the largest and smallest setting in the respective protective area. In order to receive the complete tripping characteristic, the respective characteristic sections have been brought together.
The characteristic curves indicate the behaviour of the overcurrent release when it
A) IZM…1-…: 100 … 1200 AIZM…2-…: 100 … 1200 AIZM…3-…: 400 … 1200 AThe characteristic curves apply for a circuit-brprotection module
Digital release IZM...-D...S-trip
The characteristic curves apply for a circuit-brprotection moduleL-, I-, G-trip, see universal circuit-breaker
10000
1000t [s]
100
10
1
0.1
0.1 10000.01
Ig
100 – 1200 A1)
10000
1000
100
10
1
0.1
0.1 10.01
1.25 x
t [s]
0.0tsd
IZM...-D..., IZM...-U...
eaker IZMH2…, 4
10000
tg0.1 –
I2t = const.
Isd
In – 0.8 x Icw
eaker IZMH2…,
10I / In
2 – 4 s = const.
has been activated by one of the currents flowing before the trip. If the overcurrent trip occurs directly after switch on and if the overcurrent release is not activated for this reason, the opening delay may extend by up to ms depending on the level of the overcurrent. In order to determine the total opening delay of the switch, about 15 ms are to be added to the shown opening delays for the duration of the arc.
The curves shown apply for an ambient temperature on the switch of –5 … +55 °C. The release can be operated at ambient temperatures from –20 … +70 °C (with LCD display up to 55 °C). An extended tolerance band range can apply with these temperatures.
40 V with earth-fault
L = current dependent delayed overload releaseS = short-time delayed short-circuit releaseI = non-delayed short-circuit releaseN = neutral pole overload releaseG = earth-fault release
I [A]100000
0.5 s Tolerances with the setting currentsL: trip between 1.05 and 1.2 x IrS: –0% +20%I: –0% +20%G: –0% +20%
Tolerances with the trip timesL: –20% +0%S: –0 ms +60 msI: < 50 msG: –0 ms +60 ms
0.1 – 0.4 s
I2tsd = const.
440 V with earth-fault
1I / Icw
11/65
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rs
to 6
300
A
Technical DataPermissible continuous current
Permissible continuous currentIn dependence on the ambient temperature with horizontal or vertical connectionPart no. Version Ambient temperature
Up to 55 °C 60 °C 70 °C
IZM(IN)…1(-4)-IZM…1(-4)-…630 Fixed mounted 630 630 630IN…1(-4)-630 Withdrawable units 630 630 630IZM…1(-4)-…800 Fixed mountedIN…1(-4)-800 Withdrawable unitsIZM…1(-4)-…1000 Fixed mountedIN…1(-4)-1000 Withdrawable unitsIZM…1(-4)-…1250 Fixed mountedIN…1(-4)-1250 WithdrawabIZM…1(-4)-…1600 Fixed mountIN…1(-4)-1600 Withdrawab
IZM(IN)…2(-4)-…IZM…2(-4)-…800 Fixed mountIN…2(-4)-800 WithdrawabIZM…2(-4)-…1000 Fixed mountIN…2(-4)-1000 WithdrawabIZM…2(-4)-…1250 Fixed mountIN…2(-4)-1250 WithdrawabIZM…2(-4)-…1600 Fixed mountIN…2(-4)-1600 WithdrawabIZM…2(-4)-…2000 Fixed mountIN…2(-4)-2000 WithdrawabIZM…2(-4)-…2500 Fixed mountIN…2(-4)-2500 WithdrawabIZM…2(-4)-…3200 Fixed mountIN…2(-4)-3200 Withdrawab
IZM(IN)…3(-4)-…IZM…3(-4)-…4000 Fixed mountIN…3(-4)-4000 WithdrawabIZM…3(-4)-…5000 Fixed mountIN…3(-4)-5000 WithdrawabIZM…3(-4)-…6300 Fixed mountIN…3(-4)-6300 Withdrawab
(40 °C)
Notes Figure in bra
IZM..., IN...
le unitsedle units
edle unitsedle unitsedle unitsedle unitsedle unitsedle unitsedle units
edle unitsedle unitsed 6300 A (40 °Cle units 6300 A
ckets: copper bus
Circ
uit-
brea
kfr
om 6
30 A
800 800 800800 800 8001000 1000 10001000 1000 910 (1000)1250 1250 12501250 1250 1140 (1210)1600 1600 1500 (1600)1600 1600 1390 (1490)
800 800 800800 800 8001000 1000 10001000 1000 10001250 1250 12501250 1250 12501600 1600 16001600 1600 1520 (1600)2000 2000 20002000 2000 20002500 2500 2350 (2360)2500 2500 2220 (2280)3200 3150 2910 (2940)3200 3070 2790 (2870)
4000 4000 40004000 4000 40005000 5000 5000 (4860)5000 5000 5000 (4730)
) 6150 5910 (5970) 5610 (5670)5920 5810 (5900) 5400 (5500)
bar painted black, partly with reduced, recommended terminal capacities
11/66Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A11/67
Moeller HPL0211-2007/2008 Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Technical Data Technical DataCircuit-breakers Circuit-breakers
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
IZM…1(-4)-…630 IZM…1(-4)-…800 IZM…1(-4)-…1000 IZM…1(-4)-…1250 IZM…1(-4)-…1600 Notes
B N B N B N B N B N
General 1) Time for mechanical unlatching until the contacts separate + statistical average value of the arc fault time.2) Time from mechanical unlatching until tne main contacts close.3) Time from application of the voltage until closing of the main contacts. Closing delay with overexcited closing release (5 % DF): 50 ms.4) Time from application of voltage to contact separation + statististical average value of the arc.5) Maintenance means: exchange main contacts and arcing chambers
Standards IEC/EN 60947 IEC/EN 60947Climatic proofing IEC/EN 60947-2-30 IEC/EN 60947-2-30Ambient temperature Storage °C -40 – 70 (device with LCD-display up to 55 °C) -40 – 70 (device with LCD-display up to 55 °C)
Open °C -25 – 70 (device with LCD-display up to 55 °C) -25 – 70 (device with LCD-display up to 55 °C)
Mounting position
Utilization category B B B B B B B B B BProtection type IP20, IP41 with door frame seals, IP55 with protective cover IP20, IP41 with door frame seals, IP55 with protective cover
Direction of incoming supply as required as required
Main conducting pathsRated current = rated uninterrupted current In = Iu A 630 630 800 800 1000 1000 1250 1250 1600 1600Rated impulse withstand voltage Uimp V AC 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000Rated operational voltage Ue V AC 690 690 690 690 690 690 690 690 690 690Use in IT electrical power networks up to U = 440 AC IIT kA 23 23 23 23 23 23 23 23 23 23Use in IT power networks up to U = 690 Vonly for 1000 V variants
IIT kA IZM…-4-A(V)… without overload protection on the 4th. pole are not suitable for IT grids.
IZM…-4-A(V)… without overload protection on the 4th. pole are not suitable for IT grids.
Overvoltage category/pollution degree III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3Rated insulation voltage Ui V 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000Switching capacityRated short-circuit making capacity up to 440 V 50/60 Hz Icm kA 105 143 105 143 105 143 105 143 105 143
up to 690 V 50/60 Hz Icm kA 88 105 88 105 88 105 88 105 88 105up to 1000 V 50/60 Hz Icm kA – – – – – – – – – –
Rated short-time withstand current 50/60 Hz t = 0.5 s Icw kA 42 65 42 65 42 65 42 65 42 65t = 1 s Icw kA 42 50 42 50 42 50 42 50 42 50t = 2 s Icw kA 29 35 29 35 29 35 29 35 29 35t = 3 s Icw kA 24 29 24 29 24 29 24 29 24 29t = 4 s Icw kA 21 25 21 25 21 25 21 25 21 25
Rated short-circuit breaking capacity Icn
IEC/EN 60947 operating sequence Icu O-t-CO
up to 440 V 50/60 Hz Icu kA 50 65 50 65 50 65 50 65 50 65up to 690 V 50/60 Hz Icu kA 42 50 42 50 42 50 42 50 42 50up to 1000 V 50/60 Hz Icu kA – – – – – – – – – –
IEC/EN 60947 operating sequence Ics O-t-CO-t-CO
up to 440 V 50/60 Hz Ics kA 50 65 50 65 50 65 50 65 50 65up to 690 V 50/60 Hz Ics kA 42 50 42 50 42 50 42 50 42 50up to 1000 V 50/60 Hz Ics kA – – – – – – – – – –
Operating delays
Total opening delay1) ms 38 38 38 38 38 38 38 38 38 38Closing delay2) ms 35 35 35 35 35 35 35 35 35 35Closing delay electrical (via closing release)3) ms 80 80 80 80 80 80 80 80 80 80Opening delay electrical ( via shunt release / undervoltage release)4) ms 73 73 73 73 73 73 73 73 73 73
Opening delay via trip electronics (non-delayed short-circuit release) ms 50 50 50 50 50 50 50 50 50 50
Lifespan mechanical, without maintenance Operations 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000mechanical, with maintenance5) Operations 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000electrical, without maintenance Operations 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000
electrical, with maintenance5) Operations 20000 20000 20000 20000 20000 20000 20000 20000 20000 200001000 V version Operations – – – – – – – – – –
Maximum operating frequency 690 V version Operations/h 60 60 60 60 60 60 60 60 60 601000 V version Operations/h – – – – – – – – – –
Heat dissipation at rated current In with 3-phase symmetrical load
Fixed mounting W 100 100 100 100 100 100 105 105 150 150Withdrawable units W 195 195 195 195 195 195 205 205 350 350
WeightFixed mounting 3-pole kg 43 43 43 43 43 43 43 43 43 43
4-pole kg 50 50 50 50 50 50 50 50 50 50Withdrawable units 3-pole kg 70 70 70 70 70 70 70 70 70 70
4-pole kg 84 84 84 84 84 84 84 84 84 84
Terminal capacitiesCopper bar Fixed mounting blank mm 1 x 40 x 10 1 x 40 x 10 1 x 50 x 10 1 x 50 x 10 1 x 60 x 10 1 x 60 x 10 2 x 40 x 10 2 x 40 x 10 2 x 50 x 10 2 x 50 x 10
Black mm 1 x 40 x 10 1 x 40 x 10 1 x 60 x 10 1 x 60 x 10 1 x 60 x 10 1 x 60 x 10 2 x 40 x 10 2 x 40 x 10 2 x 50 x 10 2 x 50 x 10Withdrawable units blank mm 1 x 40 x 10 1 x 40 x 10 1 x 50 x 10 1 x 50 x 10 1 x 60 x 10 1 x 60 x 10 2 x 40 x 10 2 x 40 x 10 2 x 50 x 10 2 x 50 x 10
Black mm 1 x 40 x 10 1 x 40 x 10 1 x 50 x 10 1 x 50 x 10 1 x 60 x 10 1 x 60 x 10 2 x 40 x 10 2 x 40 x 10 2 x 50 x 10 2 x 50 x 10
30˚ 30˚ 30˚ 30˚ 30˚ 30˚ 30˚ 30˚
IZM...1 IZM...1
11/68Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
from
630
A t
o 63
00 A
11/69
Moeller HPL0211-2007/2008 Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Technical Data Technical DataCircuit-breakers Circuit-breakers
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rsfr
om 6
30 A
to
6300
A
IZM…2(-4)-… IZM…3(-4)-…IZM…2(-4)-…800 IZM…2(-4)-…1000 IZM…2(-4)-…1250 IZM…2(-4)-…1600 IZM…2(-4)-…2000 IZM…2(-4)-…2500 IZM…2(-4)-…3200 4000 5000 6300B N H B N H B N H B N H B N H B N H B N H H H H
GeneralStandards IEC/EN 60947 IEC/EN 60947Climatic proofing IEC/EN 60947-2-30 IEC/EN 60947-2-30Ambient temperature
Storage °C -40 – 70 (device with LCD-display up to 55 °C) -40 – 70 (device with LCD-display up to 55 °C)Open °C -25 – 70 (device with LCD-display up to 55 °C) -25 – 70 (device with LCD-display up to 55 °C)
Mounting position
Utilization category B BProtection type IP20, IP41 with door frame seals, IP55 with protective cover IP20, IP41 with door frame seals, IP55 with protective coverDirection of incoming supply as required as required
Main conducting pathsRated current = rated uninterrupted current In = Iu A 800 800 800 1000 1000 1000 1250 1250 1250 1600 1600 1600 2000 2000 2000 2500 2500 2500 3200 3200 3200 4000 5000 6300
Rated impulse withstand voltage Uimp V AC 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000Rated operational voltage Ue V AC 690 690 690
1000690 690 690
1000690 690 690
1000690 690 690
1000690 690 690
1000690 690 690
1000690 690 690
10006901000
6901000
6901000
Use in IT electrical power networks up to U = IIT kA 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
Use in IT power networks up to U = 690 Vonly for 1000 V variants1)
kA – – 50 – – 50 – – 50 – – 50 – – 50 – – 50 – – 50 50 50 50
Overvoltage category/pollution degree III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3Rated insulation voltage Ui V 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
Switching capacityRated short-circuit making capacity
up to 440 V 50/60 Hz Icm kA 121 176 220 121 176 220 121 176 220 121 176 220 121 176 220 121 176 220 121 176 220 220 220 220
up to 690 V 50/60 Hz Icm kA 105 165 187 105 165 187 105 165 187 105 165 187 105 165 187 105 165 187 105 165 187 187 187 187
up to 1000 V 50/60 Hz Icm kA – – 95 – – 95 – – 95 – – 95 – – 95 – – 95 – – 95 105 105 105
Rated short-time withstand current 50/60 Hzt = 0.5 s Icw kA 55 80 85 55 80 85 55 80 85 55 80 85 55 80 85 55 80 85 55 80 85 85 85 100
t = 1 s Icw kA 55 65 80 55 65 80 55 65 80 55 65 80 55 65 80 55 65 80 55 65 80 80 80 100
t = 2 s Icw kA 39 46 50 39 46 50 39 46 50 39 46 50 39 46 50 39 46 50 39 46 56 56 56 70
t = 3 s Icw kA 32 37 40 32 37 40 32 37 40 32 37 40 32 37 40 32 37 40 32 37 50 46 46 57
t = 4 s Icw kA 27 32 32 27 32 32 27 32 32 27 32 32 27 32 32 27 32 32 27 32 40 40 40 50
Rated short-circuit breaking capacity Icn
IEC/EN 60947 operating sequence Icu O-t-up to 440 V 50/60 Hz Icu kA 55 80 100 55 80 100 55 80 100 55 80 100 55 80 100 55 80 100 55 80 100 100 100 100
up to 690 V 50/60 Hz Icu kA 50 75 85 50 75 85 50 75 85 50 75 85 50 75 85 50 75 85 50 75 85 85 85 85
up to 1000 V 50/60 Hz Icu kA – – 45 – – 45 – – 45 – – 45 – – 45 – – 45 – – 45 50 50 50
IEC/EN 60947 operating sequence Ics O-t-up to 440 V 50/60 Hz Ics kA 55 80 100 55 80 100 55 80 100 55 80 100 55 80 100 55 80 100 55 80 100 100 100 100
up to 690 V 50/60 Hz Ics kA 50 75 85 50 75 85 50 75 85 50 75 85 50 75 85 50 75 85 50 75 85 85 85 85
up to 1000 V 50/60 Hz Ics kA – – 45 – – 45 – – 45 – – 45 – – 45 – – 45 – – 45 50 50 50
Switching capacity 1) IZM…-4-A(V)… without overload protection on the 4th. pole are not suitable for IT grids.
30˚ 30˚ 30˚ 30˚
30˚ 30˚ 30˚ 30˚
IZM...2 IZM...2, IZM...3
Moeller HPL0211-2007/2008
11/70
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Technical DataCircuit-breakers
IZM…2(-4)-…IZM…2(-4)-…800 IZM…2(-4)-…1000 IZM…2(-4)-…1250IZMB2-…-800
IZMN2-…-800
IZMH2-…-800
IZMB2-…-1000
IZMN2-…-1000
IZMH2-…-1000
IZMB2-…-1250
IZMN2-…-1250
IZMH2-…-1250
Operating delaysTotal opening delay1) ms 73Closing delay2)
Closing delay electrical (via closing release)3)
Opening delay electrical ( via shunt release / undervoltage release)4)
Opening delay via trip electronics (non-delayed short-circuit release)5)
Lifespanmechanical, without maintenance Opermechanical, with maintenance Operelectrical, without maintenance Oper
electrical, with maintenance Oper1000 V version Oper
Maximum operating frequency690 V version Oper1000 V version Oper
Heat dissipation at rated current In with 3-phase symmetrical load
Fixed mountingWithdrawable units
WeightFixed mounting
3-pole4-pole
Withdrawable units3-pole4-pole
Terminal capacitiesCopper bar
Fixed mountingblank
Black
Withdrawable unitsblank
Black
Notes
IZM...2
mm
m
m
ationsationsations
ationsations
ations/hations/h
WW
kk
kk
m
m
m
m
s 100s 100
s 73
s 50
10000 10000 10000 10000 10000 10000 10000 10000 1000015000 15000 15000 15000 15000 15000 15000 15000 150007500 7500 7500 7500 7500 7500 7500 7500 7500
15000 15000 15000 15000 15000 15000 15000 15000 15000> 1000 > 1000 > 1000 > 1000 > 1000 > 1000 > 1000 > 1000 > 1000
60 60 60 60 60 60 60 60 60– – 20 – – 20 – – 20
40 40 40 45 45 45 80 80 8085 85 85 95 95 95 165 165 165
g 56 56 56 56 56 56 56 56 56g 67 67 67 67 67 67 67 67 67
g 91 91 91 91 91 91 91 91 91g 109 109 109 109 109 109 109 109 109
m 1 x 50 x 10 1 x 60 x 10 2 x 40 x 10
m 1 x 50 x 10 1 x 60 x 10 2 x 40 x 10
m 1 x 50 x 10 1 x 60 x 10 2 x 40 x 10
m 1 x 50 x 10 1 x 60 x 10 2 x 40 x 10
1) Time for mechanical unlatching until the contacts separate + statistical average value of the arc fault time.
2) Time from mechanical unlatching until tne main contacts close.3) Time from application of the voltage until closing of the main contacts. Closing delay with over-
excited closing release (5 % DF): 50 ms.4)
Time from application of voltage to contact separation + statististical average value of the arc.5) Exception release for ‌protection of systems (XZMA): 85 ms.6) Maintenance means: exchange main contacts and arcing chambers11/71
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rs
to 6
300
A
Technical DataCircuit-breakers
IZM…3(-4)-…IZM…2(-4)-…1600 IZM…2(-4)-…2000 IZM…2(-4)-…2500 IZM…2(-4)-…3200 4000 5000 6300IZMB2-…-1600
IZMN2-…-1600
IZMH2-…-1600
IZMB2-…-2000
IZMN2-…-2000
IZMH2-…-2000
IZMB2-…-2500
IZMN2-…-2500
IZMH2-…-2500
IZMB2-…-3200
IZMN2-…-3200
IZMH2-…-3200
IZMH3-…-4000
IZMH3-…-5000
IZMH3-…-6300
73100100
73
50
10000 10000 10000 10000
15000 15000 15000 15000
7500 7500 7500 7500
15000 15000 15000 15000
> 1000 > 1000 > 1000 > 1000
60 60 60 60– – 20 –
85 85 85 180175 175 175 320
56 56 56 5667 67 67 67
91 91 91 91109 109 109 109
2 x 50 x 10 3 x 50 x
2 x 50 x 10 3 x 50 x
2 x 50 x 10 3 x 50 x
2 x 50 x 10 3 x 50 x
IZM...2, IZM...3
10000 1000
15000 1500
7500 7500
15000 1500
> 1000 > 10
60 60– 20
180 180320 320
56 5667 67
91 91109 109
10
10
10
10
Circ
uit-
brea
kfr
om 6
30 A
0 10000 10000 10000 10000 10000 10000 5000 5000 5000
0 15000 15000 15000 15000 15000 15000 10000 10000 10000
7500 7500 7500 4000 4000 4000 2000 2000 2000
0 15000 15000 15000 15000 15000 15000 10000 10000 10000
00 > 1000 > 1000 > 1000 > 1000 > 1000 > 1000 > 1000 > 1000 > 1000
60 60 60 60 60 60 60 60 60– – 20 – – 20 20 20 20
270 270 270 410 410 410 520 630 900520 520 520 710 710 710 810 1050 1600
59 59 59 64 64 64 82 82 9071 71 71 77 77 77 99 99 108
102 102 102 113 113 113 148 148 166123 123 123 136 136 136 190 190 227
2 x 100 x 10 3 x 100 x 10 4 x 100 x 10
5 x 100 x 10
6 x 120 x 10
2 x 100 x 10 3 x 100 x 10 4 x 100 x 10
4 x 120 x 10
6 x 120 x 10
2 x 100 x 10 3 x 100 x 10 4 x 100 x 10
5 x 100 x 10
6 x 120 x 10
2 x 100 x 10 3 x 100 x 10 4 x 100 x 10
4 x 120 x 10
6 x 120 x 10
Moeller HPL0211-2007/2008
11/72
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Technical DataSwitch-disconnectors
IN…1(-4)-630 IN…1(-4)-800 IN…1(-4)-1000 IN…1(-4)-1250 IN…1(-4)-1600INB1-…-630
INN1-…-630
INB1-…-800
INN1-…-800
INB1-…-1000
INN1-…-1000
INB1-…-1250
INN1-…-1250
INB1-…-1600
INN1-…-1600
GeneralStandards IEC/EN 60947
VDE 0660Climatic proofing IEC/EN 60947-2-30Ambient temperature
Storage Open
Mounting position
Utilization categoryProtection typeDirection of incoming supply
Main conducting pathsRated current = rated uninterrupted current
Rated impulse withstand voltage Rated operational voltage
Overvoltage category/pollution degreeRated insulation voltage
Switching capacityRated short-circuit making capacity
up to 440 V 50/60 Hz
up to 690 V 50/60 Hz
up to 1000 V 50/60 Hz
Rated short-time withstand current 50/60 Hzt = 0.5 s
t = 1 s
t = 2 s
t = 3 s
t = 4 s
Operating delaysTotal opening delay1)
Closing delay2)
Closing delay electrical (via closing release)3)
Opening delay electrical ( via shunt release / undervoltage release)4)
Lifespanmechanical, without maintenancemechanical, with maintenance5)
electrical, without maintenanceelectrical, with maintenance5)
1000 V versionMaximum operating frequency
690 V version1000 V version
Heat dissipation at rated current In with 3-phase symmetrical load
Fixed mountingWithdrawable units
Notas 1) Time for mechani2) Time for mechani3) Time from applica4) Time from applica5) Maintenance mea
IN...1
°C°C
In = Iu A
Uimp V AUe V A
Ui V
Icm kA
Icm kA
Icm kA
Icw kA
Icw kA
Icw kA
Icw kA
Icw kA
msmsms
ms
OperationsOperationsOperations
OperationsOperationsOperations/Operations/
WW
cal unlatching ucal untlaching ution of the voltation of voltage ns: exchange m
-40/70-25/70
BIP20, IP40 with door sealing frame, IP55 with protective coveras required
630 630 800 800 1000 1000 1250 1250 1600 1600
C 12000C 690
III/31000
105 143 105 143 105 143 105 143 105 143
88 105 88 105 88 105 88 105 88 105
–
42 65 42 65 42 65 42 65 42 65
42 50 42 50 42 50 42 50 42 50
29 35 29 35 29 35 29 35 29 35
24 29 24 29 24 29 24 29 24 29
21 25 21 25 21 25 21 25 21 25
738080
73
10000200001000020000–
h 60h –
30˚ 30˚ 30˚ 30˚
100 105 170195 205 350
ntil contact separation + statistical average value of the arc fault quench time.ntil closing of the main contacts.ge until closing of the main contacts. Closing delay with overexcited closing release (5 % DF): 50 ms.
to contact separation + statististical average value of the arc.ain contacts and arcing chambers
11/73
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rs
to 6
300
A
Technical DataSwitch-disconnectors
IN…1(-4)-630 IN…1(-4)-800 IN…1(-4)-1000 IN…1(-4)-1250 IN…1(-4)-1600
WeightFixed mounting 3-pole kg 43 43 43 43 43
4-pole kg 50 50 50 50 50Withdrawable units 3-pole kg 70 70 70 70 70
4-pole kg 84 84 84 84 84
Terminal capacitiesCopper bar
Fixed mountingblankBlackWithdrawable unitsblankBlack
IN…
WeightFixed mounting
3-pole kg 564-pole kg 67
Withdrawable units3-pole kg 914-pole kg 109
Terminal capacitiesCopper bar
Fixed mountingblank mm 1 xBlack mm 1 x
Withdrawable unitsblank mm 1 xBlack mm 1 x
WeightFixed mounting
3-pole4-pole
Withdrawable units3-pole4-pole
Terminal capacitiesCopper bar
Fixed mountingblankBlack
Withdrawable unitsblankBlack
IN...1, IN...2, IN...3
2(-4)-800 IN…
5667
91109
50 x 10 1 x 50 x 10 1 x
50 x 10 1 x 50 x 10 1 x
Circ
uit-
brea
kfr
om 6
30 A
mm 1 x 40 x 10 1 x 50 x 10 1 x 60 x 10 2 x 40 x 10 2 x 50 x 10mm 1 x 40 x 10 1 x 50 x 10 1 x 60 x 10 2 x 40 x 10 2 x 50 x 10
mm 1 x 40 x 10 1 x 50 x 10 1 x 60 x 10 2 x 40 x 10 2 x 50 x 10mm 1 x 40 x 10 1 x 50 x 10 1 x 60 x 10 2 x 40 x 10 2 x 50 x 10
2(-4)- IN…2(-4)- IN…2(-4)- IN…2(-4)- IN…2(-4)- IN…2(-4)-
56 56 56 59 6467 67 67 71 77
91 91 91 102 113109 109 109 123 136
60 x 10 2 x 40 x 10 2 x 50 x 10 3 x 50 x 10 2 x 100 x 10 3 x 100 x 10 60 x 10 2 x 40 x 10 2 x 50 x 10 3 x 50 x 10 2 x 100 x 10 3 x 100 x 10
60 x 10 2 x 40 x 10 2 x 50 x 10 3 x 50 x 10 2 x 100 x 10 3 x 100 x 10 60 x 10 2 x 40 x 10 2 x 50 x 10 3 x 50 x 10 2 x 100 x 10 3 x 100 x 10
IN…3(-4)-4000 IN…3(-4)-5000 IN…3(-4)-6300
kg 82 82 90kg 99 99 108
kg 148 148 166kg 190 190 227
mm 4 x 100 x 10 5 x 100 x 10 6 x 120 x 10mm 4 x 100 x 10 4 x 120 x 10 6 x 120 x 10
mm 4 x 100 x 10 6 x 100 x 10 6 x 120 x 10mm 4 x 100 x 10 4 x 120 x 10 6 x 120 x 10
11/74Ci
rcui
t-br
eake
rs, s
wit
ch-d
isco
nnec
tors
fr
om 6
30 A
to
6300
A11/75
Moeller HPL0211-2007/2008 Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Technical Data Technical DataSwitch-disconnectors Switch-disconnectors
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
IN…2(-4)-800 IN…2(-4)-1000 IN…2(-4)-1250 IN…2(-4)-1600 IN…2(-4)-2000 IN…2(-4)-2500 IN…2(-4)-3200 IN…3(-4)-4000
IN…3(-4)-5000
IN…3(-4)-6300
INB2-…-800
INN2-…-800
INH2-…-800
INB2-…-1000
INN2-…-1000
INH2-…-1000
INB2-…-1250
INN2-…-1250
INH2-…-1250
INB2-…-1600
INN2-…-1600
INH2-…-1600
INB2-…-2000
INN2-…-2000
INH2-…-2000
INB2-…-2500
INN2-…-2500
INH2-…-2500
INB2-…-3200
INN2-…-3200
INH2-…-3200
INH3-…-4000
INH3-…-5000
INH3-…-6300
GeneralStandards IEC/EN 60947VDE 0660 IEC/EN 60947VDE 0660Climatic proofing IEC/EN 60947-2-30 IEC/EN 60947-2-30Ambient temperature
Storage °C -40/70 -40/70Open °C -25/70 -25/70
Mounting position
Utilization category B BProtection type IP20, IP40 with door sealing frame, IP55 with protective cover IP20, IP40 with door sealing frame, IP55 with protective coverDirection of incoming supply as required as required
Main conducting pathsRated current = rated uninterrupted current In = Iu A 800 800 800 1000 1000 1000 1250 1250 1250 1600 1600 1600 2000 2000 2000 2500 2500 2500 3200 3200 3200 4000 5000 6300Rated impulse withstand voltage Uimp V AC 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000Rated operational voltage Ue V AC 690 690 690
1000690 690 690
1000690 690 690
1000690 690 690
1000690 690 690
1000690 690 690
1000690 690 690 690
10006901000
6901000
Overvoltage category/pollution degree III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3Rated insulation voltage Ui V 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
Switching capacityRated short-circuit making capacity
up to 440 V 50/60 Hz Icm kA 121 176 220 121 176 220 121 176 220 121 176 220 121 176 220 121 176 220 121 176 220 220 220 220up to 690 V 50/60 Hz Icm kA 105 165 187 105 165 187 105 165 187 105 165 187 105 165 187 105 165 187 105 165 187 187 187 187up to 1000 V 50/60 Hz Icm kA – – 95 – – 95 – – 95 – – 95 – – 95 – – 95 – – 95 105 105 105
Rated short-time withstand current 50/60 Hzt = 0.5 s Icw kA 55 80 85 55 80 85 55 80 85 55 80 85 55 85 85 55 80 85 55 80 85 85 85 100t = 1 s Icw kA 55 65 80 55 65 80 55 65 80 55 65 80 55 65 80 55 65 80 55 65 80 80 80 100t = 2 s Icw kA 39 46 50 39 46 50 39 46 50 39 46 50 39 46 50 39 46 50 39 46 56 56 56 70t = 3 s Icw kA 32 37 40 32 37 40 32 37 40 32 37 40 32 37 40 32 37 40 32 37 50 50 46 57t = 4 s Icw kA 27 32 32 27 32 32 27 32 32 27 32 32 27 32 32 27 32 32 27 32 40 40 40 50
Operating delaysTotal opening delay1) ms 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34Closing delay2) ms 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35Closing delay electrical (via closing release)3) ms 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80
Opening delay electrical ( via shunt release / undervoltage release)4)
ms 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73
Lifespanmechanical, without maintenance Operations 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 5000 5000 5000mechanical, with maintenance5) Operations 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 10000 10000 10000electrical, without maintenance Operations 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 4000 4000 4000 2000 2000 2000electrical, with maintenance5) Operations 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 10000 10000 100001000 V version Operations – – 1000 – – 1000 – – 1000 – – 1000 – – 1000 – – 1000 – – 1000 1000 1000 1000
Maximum operating frequency690 V version Operations/h 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 601000 V version Operations/h – – 20 – – 20 – – 20 – – 20 – – 20 – – 20 – – 20 20 20 20
Heat dissipation at rated current In with 3-phase symmetrical load
Fixed mounting W 40 40 40 40 40 40 80 80 80 85 85 85 180 180 180 270 270 270 410 410 410 520 630 900Withdrawable units W 95 95 95 95 95 95 165 165 165 175 175 175 320 320 320 520 520 520 710 710 710 810 1050 1600
Notes Switching capacity in N pole = 60 %1) Time for mechanical unlatching until contact separation + statistical average value of the arc fault quench time.2) Time for mechanical untlaching until closing of the main contacts.3) Time from application of the voltage until closing of the main contacts. Closing delay with overexcited closing release (5 % DF): 50 ms.4) Time from application of voltage to contact separation + statististical average value of the arc.5) Maintenance means: exchange main contacts and arcing chambers
30˚ 30˚ 30˚ 30˚ 30˚ 30˚ 30˚ 30˚
IN...2 IN...2, IN...3
Moeller HPL0211-2007/2008
11/76
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rsfr
om 6
30 A
to
6300
ATechnical DataControl unit
IZM…-A… IZM…-V… IZM…-U… IZM…-D…(XZMA) IZM…1/2… IZM…3… ZM…1/2… IZM…3… IZM…1/2… IZM…3…
Control unitsOverload protection L
Setting range Ir A 0.5 – 1.0 x In 0.4 – 1.0 x In 0.4 – 1.0 x In 0.4 – 1.0 x In 0.4 – 1.0 x In 0.4 – 1.0 x In 0.4 – 1.0 x InDelay time with
6 x Ir tr
6 x Ir with time delay setting to overcome current peaks to J
tr
6 x Ir with time delay to overcome current peaks set to I4t
tr
Phase-failure sensitivity
Thermal memory
Tolerance
ZSI functionShort-time delayed short-circuit protection
Setting range Isd
Delay time tsd
Jsd with 12 x In tsd
Non-delayed short-circuit protection ICan be de-activated
Adjustment rangetolerance: g 0 … + 20%
Ii
N-conductor protection NSetting range
Earth-fault protection G
Setting range of the response current Ig for the trip
Ig
Setting range of the response current Ig for the alarm
Ig
Delay time tg
Delay time with I2t tg
Tripping function
Alarm function
ZSI functionAcquisition of earth-fault current through summation current transformation with built-in or external transducer for the N conductor
Acquisition of earth-fault current through external transducer for the protective conductor
Notes 1) Control unit XZMR rei.e. a) with paramete
2) IZM…-4-A(V)… with
IZM-...
s 10s
s
Protectiv
A
ms
ms
A 2 – 8 x
A
A
msms
–
–
ceives a plus opr assignment moout overload pro
10 10 – – – –2 – 30 2 – 30 2 – 30 2 – 30
1 … 5 1 … 5 1 … 5 1 … 5
only with tsd = 20 (motor protection) ms
only with tsd = 20 (motor protection) ms
ON/OFF via Menu/Comm
can be switched on/off ON/OFF via Menu/Comm
e function to IEC/EN 60947 Protective function conform to IEC/EN 60947,current display F 5 %measurement function basic values F 1 %measurement function derived values F 3 %with option “IZM-XEM-ZSI” with option “IZM-XEM-ZSI”
1.25 – 12 x In 1.25 – 12 x In 1.25 x In – 0.8 x Icw (max. 0.8 x Icw)
0, 20 (motor protection), 100, 200, 300, 400
20 (motor protection), 100, 200, 300, 400, OFF
20, 100, 200, 300, 400, 500, 1000, 2000, 3000, 4000, OFF
100, 200, 300, 400, OFF 100, 200, 300, 400, OFF
OFF2) OFF2) OFF via Menu/Comm2)
OFF via Menu/Comm2)
In f 20 x In (max. 50 kA) 1.5 x In … 0.8 x Ics (max. 0.8 x Ics), OFF: Ics = Icw (0.5 s)
1.5 x In … 0.8 x Ics (max. 0.8 x Ics), OFF: Ics = Icw (0.5 s)
0 %, 100 % of In, can be switched on/off with slide switch
0 %, 50 %, 100 % of In, can be switched on/off with slide switch
Via menu/COMM 50 % to 200 % of In
Option for fixed mounting Module can be retrofitted Module can be retrofitted
OFF, 100, 300, 600, 900, 1200
OFF, 400, 600, 800, 1000, 1200
OFF, 100, 300, 600, 900, 1200
OFF, 400, 600, 800, 1000, 1200
100–1200 400–1200
100, 300, 600, 900, 1200
400, 600, 800, 1000, 1200
100–1200 400–1200
100, 200, 300, 400, 500 100, 200, 300, 400, 500 100, 200, 300, 400, 500100, 200, 300, 400, 500 100, 200, 300, 400, 500
can be switched on/off can be switched on/off ON/OFF via Menu/Comm
– – – – ON/OFF via Menu/Comm
with option “IZM-XEM-ZSI” with option “IZM-XEM-ZSI”Yes Yes yes, can be selected yes, can be selected
– – yes, can be selected yes, can be selected
tion “+IZM-XZMR”. All settings only possible via communication interfaces (via Comm), dule IZM-XEM-PG(E) or b) via PROFIBUS.tection on the 4th. pole are not suitable for IT grids.
11/77
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rs
to 6
300
A
Technical DataAuxiliary contacts
IZM-XHI... standard auxiliary contact
IZM-XHIB ready to switch on message
IZM-XHIA trip-indicating auxiliary contact
Position signalling switch IZM-XHIAV...
Auxiliary contactsRated insulation voltage
AC Ui V AC 500 – – 440DC Ui V DC 500 – – 250
Rated operational voltage Ue V AC/DCV AC/DC
52
Rated impulse withstand voltage Uimp kV 4
Short-circuit protection
max. fuseFuseless
Rated breaking capacityAC12
24 230 V110 … 127 V220/230 V400 V500 V
AC-1524 230 V110/127 V220/230 V400 V440 V500 V
DC1224 V30 V I
48 V110 V220 V
DC-1324 V48 V100 V220/250 V400 V
DC – -24 V48 V110 V220 V
Terminal capacitiesFlexible without ferrule
Flexible with ferrule
Notes
IZM-XHI...
A gL 10Type FA
A 10A 10A 10A 10A 10
A 4A 4A 4A 3A –A 2
A 10A –A 8A 3.A 1
A 8A 4A 1.A 0.A –
A 10A 4A 1.A 0.
mm2 2
mm2 2
TS
Circ
uit-
brea
kfr
om 6
30 A
0020
220220
230220
440250
– – 4
2 6 8Z-C10 – – FAZ-C6
– – –0.14 – 130.1 6 13– – –– – –
– – –– – 5– – 4– – 3– – 3– – –
0.2 6 13– – 10– – 2.5
5 – 0.4 0.80.1 0.2 0.6
– – 3– – –
2 – – –4 – – 0.1
– – –
– – –– – –
2 – – –4 – – –
x (0.5 – 2.5) 2 x (0.5 – 2.5) 2 x (0.5 – 2.5) 2 x (0.5 – 2.5)
x (0.5 – 1.5) 2 x (0.5 – 1.5) 2 x (0.5 – 1.5) 2 x (0.5 – 1.5)
erminal capacity:tandard spring-loaded terminal
Moeller HPL0211-2007/2008
11/78
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
Technical DataVoltage release, motor operator
Voltage releasesClosing release +IZM-XE/A, IZM-XE/A
+IZM-XA(1) shunt release
Undervoltage release IZM-XU(V)
100 % duty factor 5 % duty factor 100 % duty factor delayed t =....etc non-delayed and t = 200 ms
Voltage releasesRated control voltage
AC 50/60 Hz Us V
DC Us V
Power consumptionAC, 50/60 Hz VADC W
Circuit-breaker response time
ms
Minimum command time ms
Operating rangeDrop-out voltage x Us
Pick-up voltage x Us
Enhanced battery operation range
Pick-up voltage x Us
Short-circuit protection
DIAZED fuses (utilization category gL)Miniature circuit-breaker with characteristic C
W
Terminal capacitiesFlexible without ferrule mm2
Flexible with ferrule mm2
Notes
Motor operatorsRated control voltage
AC 50/60 HzDC
Operating rangeExtended operating range for battery operatioto 220 V DCNecessary time requirement for charging of tspring-operated stored energy mechanism wiStarting current
Power consumptionAC 50/60 HzDC
Short-circuit protection DIAZED fuses (utilization category gL)Miniature circuit-breaker with charactC
Terminal capacitiesFlexible without ferruleFlexible with ferrule
Notes
IZM-X...
110, 230
24, 30, 48, 60, 1220
151580
60
0.85 – 1.1
0.7 – 1.26
1 A TDz (slow)
1 A600
2 x (0.5 – 2.5)
2 x (0.5 – 1.5)
Terminal capaciStandard springRated power unAC pickup powe
Us
Us
x Us
n 24 V x Us
he th 1 x
eristic
110 … 127, 208 … 240
110, 230 110 … 127, 208 … 240, 380 … 415
110 … 127, 208 … 240, 380 … 415
10, 24, 48, 110 … 125, 220 … 250
24, 30, 48, 60, 110, 220
48, 110 … 125, 220 … 250
24, 30, 48, 60, 110 … 125, 220 … 250
15 15 5 (pick-up 200) 5 (pick-up 200)15 15 5 (pick-up 200) 5 (pick-up 200)50 73 80 non-delayed,
otherwise according to delay time
80 non-delayed, otherwise according to delay time
25 60 – –
0.35 – 0.7 0.35 – 0.70.85 – 1.1 0.85 – 1.1 0.85 – 1.1 0.85 – 1.1
0.7 – 1.26 0.7 – 1.26 0.85 – 1.26 0.85 – 1.26
1 A TDz (slow) 1 A TDz (slow) 1 A TDz (slow) 1 A TDz (slow)
1 A600 1 A600 1 A600 1 A600
2 x (0.5 – 2.5) 2 x (0.5 – 2.5) 2 x (0.5 – 2.5) 2 x (0.5 – 2.5)
2 x (0.5 – 1.5) 2 x (0.5 – 1.5) 2 x (0.5 – 1.5) 2 x (0.5 – 1.5)
ty:-loaded terminaldervoltage release:r 200 VA or DC 200 W
IZM-XM24-30DC IZM-XM48-60DC IZM-XM110AC/DC IZM-XM230AC/220DC
V 110 … 125 208 … 250V 24 … 30 48 … 60 110 … 127 220 … 225V 0.85 – 1.1 0.85 – 1.1 0.85 – 1.1 0.85 – 1.1V 0.7 – 1.26 0.7 – 1.26 0.7 – 1.26 0.7 – 1.26
s 10 10 10 10
A 19.3 (24 V DC)24.5 (30 V DC)
7.6 (48 V DC)11.6 (60 V DC)
8.8 (110 V AC)7 (110 V DC)
3.9 (220 V AC)2.6 (220 V DC)
VA 110 110 110 110W 110 110 110 110
2 A TDz (slow) 2 A TDz (slow) 2 A TDz (slow) 2 A TDz (slow)W 2 A 2 A 1 A600 1 A600
mm2 2 x (0.5 – 2.5) 2 x (0.5 – 2.5) 2 x (0.5 – 2.5) 2 x (0.5 – 2.5)mm2 2 x (0.5 – 1.5) 2 x (0.5 – 1.5) 2 x (0.5 – 1.5) 2 x (0.5 – 1.5)
Terminal capacity:Standard spring-loaded terminal
11/79
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rs
to 6
300
A
Technical dataCurrent consumption, safety clearances
Maximum continuous cur-rent
Max. starting current Part no.
I
mA A
Current consumption for the communication moduleTrip XZMU 120 2 IZM-XZMUTrip XZMR 120 2 IZM-XZMRTrip XZMDMeasuring function XMHBreaker Status Sensor XBSSCommunication module XCOM-DPZSI moduleDigital output module with rotary coding switch, relay outpuDigital output module, configurable, relay ouAnalog output moduleDigital input modulePG (E) parameter assignment module
Safety clearance to live partsRated operational voltage
Fixed mountedabove control circuit plugSide (each)Rear
Withdrawable unitswithout arc chute cover
above control circuit plugSide (each)Rear
with arc chute coverabove control circuit plugSide (each)Rear
Safety clearance to earthed partsRated operational voltage
Fixed mountedabove control circuit plugSide (each)Rear
Withdrawable unitswithout arc chute cover
above control circuit plugSide (each)Rear
with arc chute coverabove control circuit plugSide (each)Rear
Notes 1) Value for plate2) 40 mm (IZM...2
to the upper ed
IZM..., IN...
tputs
V AC
mmmmmm
mmmmmm
mmmmmm
V AC
mmmmmm
mmmmmm
mmmmmm
s, 0 mm for supp-..., IN...2-... 70 m
ge of the controCirc
uit-
brea
kfr
om 6
30 A
170 2 IZM-XZMD120 0.12 +IZM-XMH40 0.11 +IZM-XBSS125 0.28 +IZM-XCOM-DP50 0.125 IZM-XEM-ZSI
ts 180 0.125 IZM-XEM-6DO-R180 0.125 IZM-XEM-6PDO-R110 0.8 IZM-XEM-4AO30 0.125 IZM-XEM-6DI250 0.35 IZM-XEM-PG
IZM...1-..., IN...1-... IZM...2-..., IN...2-... IZM...3-..., IN...3-...440 690 440 690 1000 440 690 1000
150 300 250 600 430 75 500 43020 50 50 100 100 20 100 10020 125 20 140 125 20 125 125
150 300 250 600 350 50 500 35020 50 50 100 100 20 100 10014 14 14 30 14 14 14 14
14 14 14 14 – 14 14 –100 100 50 225 – 50 200 –14 14 14 14 – 14 14 –
IZM...1-..., IN...1-... IZM...2-..., IN...2-... IZM...3-..., IN...3-...440 690 440 690 1000 440 690 1000
751) 751) 751) 751) 180 751) 751) 1800 0 0 0 0 0 0 00 0 0 0 0 0 0 0
501) 501) 501) 501) 100 501) 501) 1000 0 0 0 0 0 0 00 0 0 0 0 0 0 0
0 0 0 0 0 0 –02) 02) 02) 02) 02) 02) –0 0 0 0 0 0 –
orts and grillsm) for plates, that cover side apertures in the drawer area. All safety clearances above the switch relate
l circuit plug - not to the upper edge of the arcing chamber! See dimensional drawings.
Moeller HPL0211-2007/2008
11/80
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rs
from
630
A t
o 63
00 A
DimensionsExternal dimensions, door cut-out
Circuit-breakers Switch-disconnectors
Door cut-out for operating panelWhen door seal is used
a Mounting areab Centre of IZM/IN operating panelc 8 mounting holes for door seald 3 mounting holes for door interlock
ab
Fxed mounting Withdrawable unitsa b c1) a b c1)
IZM…1-…, IN…1-… 320 434 357 320 460 471IZM…2-…, IN…2-… 460 434 357 460 460 471IZM…3-…, IN…3-… 704 434 357 704 460 471IZM…1-4…, IN…1-4… 410 434 357 410 460 471
40120
300
314
40 120
R5 R5
da
b
c
65o 5.5
140
175
350
o 5.5
140
o 5.5
40
21
12 11.5
IZM..., IN...
185
180
1) including dimensions for horizontal connection.Height “b” up to the control circuit plug upper edge as screw termination for circuit-breaker/switch-disconnector with UeF690 V. Deviations for Ue=1000 V see detail drawings.
Door cut-out with edge protectionCut-out after mounting the edge protection
c
IZM…2-4…, IN…2-4… 590 434 357 590 460 471IZM…3-4…, IN…3-4… 914 434 357 914 460 471
340
295
240
11/81
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rsto
630
0 A
DimensionsFixed mounting and optional terminations, 3 and 4 pole
Standard version for horizontal connection Optional terminationsFront connection (single hole fitting)IZM1-XAT1F...
15270
300 10
390
434
123.
5
439.
5275
e d
a
c
60.5
33.5h
i
541.
5
410
320
58139
60
55
90 90 90
cg g
o 13.5
4 x o 9
35
k
150
275
90 90 9060
c
aa
451
6c
421
ko 13.5
35
Rated current Iu a b cup to 1000 A 10 10 11250 – 1600 A 15 15 1
IZM…1-…, IN…1-…, IZM1-XAT…
a Mounc Groovd Controe Controf Dimeng Attachh Interloi Key opk ConneWhen fro
230
5.5
150
130
210
20
05
Circ
uit-
brea
kfr
om 6
30 A
Front connection (double-hole fitting) according to DIN 43673
IZM1-XATF...
Vertical connection IZM1-XATV...
ting area for removal of the arcing chamberses (4 mm wide, 5 mm deep) for supporting phase isolation plates in the systeml circuit plug with screw terminalsl circuit plug with spring-loaded terminalsion for internal area of closed switchgear system doorment points for circuit-breaker mounting in the systemck in OFF (optional accessories)eration (optional accessories)ction areant connections are used, a partition between the busbar and arcing space must be fitted on the system side
45
127
106f
7632
7.5
11
82
c 47
26k
90 90 9060
55 55 55 55
35
82
c 47
6
3454
1
90 90 9060
55 55 55 55
c
14
80 4042
140
80
ko 13.5
k
113.5
35
128.5
127.
530
267.
5
60
o 13.5
k
60 90 90 90
b
c
Moeller HPL0211-2007/2008
11/82
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rsfr
om 6
30 A
to
6300
ADimensionsWithdrawable mounting and optional terminations, 3 and 4 pole
Standard version for horizontal connection Optional terminationsFront connection (single hole fitting)
IZM1-XAT1F...-AV
55
270
3013
210
300
320
e
123.
527
546
5.5
j j
d
55 55 55 55
68139
25270
320
410
o 13.5
38
55
15
90 90 90
c
j j
m no
150a
a
275
460
382.5
367.5
2031
260
350
6928
7
k
603
35
373
ko 13.5
c
Rated current Iu a b cup to 1000 A 10 10 11250 – 1600 A 15 15 1
IZM…1-…, IN…1-…, IZM1-XAT
c
40
27
42
o14
c Grooved Controe Controf Dimenj Fixing k Connem IZM inn IZM ino IZM inWhen fron
05
Front connection (double-hole fitting) according to DIN 43673
IZM1-XATF...-AV
Vertical connection IZM1-XATV...-AV
Flanged connection IZM1-XATA...-AV
s (4 mm wide, 5 mm deep) for supporting phase isolation plates in the system
45
88.5
121.5
140.5
220
j
58f
7632
7.5
169.5
c 62.5114
90 90 90
55 55 55 55
15
26
35
k
62.5
6
169.5c
34
493
90 90 90
55 55 55 55
15
14
408080 40
373
o 13.5 k
k
150
165
127.
5
30
267.
5
60
o 13.5
k38
15 90 90 90
b
c
121
14 90 9015 90
55 55 55 55
c
o M12
142.
5
5959
2633
282.
5
l circuit plug with screw terminalsl circuit plug with spring-loaded terminalsion for internal area of closed switchgear system doorholes, o 10 mmction area connected position test position disconnected positiont connections are used, a partition between the busbar and arcing space must be fitted on the system side
11/83
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rsto
630
0 A
DimensionsWithdrawable mounting and optional terminations, 3 and 4 pole
Standard version for horizontal connection Optional terminationsFront connection (single hole fitting)
IZM2-XAT1F...
10
270 85
440
570
e
123.
527
5
435.
5
434
d
150
460
128
130
90
130 130 90
30
30
139
590
35
o 13.5g g
4 x o 9
k
13013090 130
a
451.
5541.
5
l
aa
c
421
ko 13.5
35
6451
Rated current Iu a bup to 2000 A 10 12500 A 15 13200 A 30 3
IZM…2-…, IN…2-…, IZM2-XAT
275
c0 105 200 20
Circ
uit-
brea
kfr
om 6
30 A
Front connection (double-hole fitting) according to DIN 43673
Vertical connection
a Mounting area for removal of the arcing chambersAt Ue = 1000 V 175 mm is required, in order to remove the arcing chamber. c Grooves (4 mm wide, 5 mm deep) for supporting phase isolation plates in the systemd Control circuit plug with screw terminalse Control circuit plug with spring-loaded terminalf Dimension for internal area of closed switchgear system doorg Attachment points for circuit-breaker mounting in the systemk Connection areal Circuit-breaker upper edge - 1000 V AC version onlyWhen front connections are used, a partition between the busbar and arcing space must be fitted on the system side
150
45
5.5
f
c
210
230
106
127
7632
7.5
130
20
90 130 130 130
40
90 90 90 90
c
26k 35
82
c
4711
c
14 4040
421
90 130 130 130
40
90 90 90 90
8080
o 13.5 k
k
82
c
6
47
541
34
113.5
35
128.5
134.
5
98290
30
30
o 13.5
k
90 130 130 130
b
c
Moeller HPL0211-2007/2008
11/84
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rsfr
om 6
30 A
to
6300
ADimensionsWithdrawable mounting and optional terminations, 3 and 4 pole
Standard version for horizontal connection Optional terminationsFront connection (single holle fitting)
IZM2-XAT1F...-AV
55350
270 40
480
j
e
j
123.
527
546
5.5
d
30
138139
95270
460
590
30
k
38o 13.5
55
90 90 90 90
45 130 130 130
jj
nm
o
150
a 275
a
367.5
382.5
2
40.5
l
530
400
c
373
35
ko 13.5
403 6
Rated current Iu a bup to 2000 A 10 12500 A 15 13200 A 30 3
IZM…2-…, IN…2-…, IZM2-XAT
2
j
460
407
42
o14
287
69
31 20
c0 105 200 20
Front connection (double-hole fitting) according to DIN 43673
IZM2-XATF...-AV
Vertical connection IZM2-XATV...-AV
Flanged connection IZM2-XATA...-AV
88.5
121.5
140.5
45
58
20 f
7632
7.5
517
55 130 130 130
40
90 90 90 90
45
2635
k
c
62.5
169.5
11
c
14 4040
373
55 130 130 130
40
90 90 90 90
45
8080
o 13.5 k
k34
493
c 62.5
169.5
6
157
172
135
100290
30
30
38
k
55 45 130 130 130
b
c
121
45 130 130 130
4090
c
5959
2633
282.
5
142.
5
o M12
At Ue = 1000 V 175 mm is required, in order to remove the arcing chamber. c Grooves (4 mm wide, 5 mm deep) for supporting phase isolation plates in the systemd Control circuit plug with screw terminalse Control circuit plug with spring-loaded terminalf Dimension for internal area of closed switchgear system doorj Fixing holes, o 10 mmk Connection areal Circuit-breaker upper edge - 1000 V AC version onlym IZM in connected positionn IZM in test positiono IZM in disconnected positionWhen front connections are used, a partition between the busbar and arcing space must be fitted on the system side
11/85
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rsto
630
0 A
DimensionsFixed mounted, 3 and 4 pole
Standard version horizontal connection F 6300 A
a Mounting area for removal of the arcing cAt Ue = 1000 V 175 mm is required, in oc Grooves (4 mm wide, 5 mm deep) for supd Control circuit plug with screw terminalse Control circuit plug with spring-loaded tef Dimension for internal area of closed swig Attachment points for circuit-breaker mouk Connection areal Circuit-breaker upper edge - 1000 V AC vWhen front connections are used, a partition
20270
680
890
e d
434
123.
527
5
30
160
210
914
704
210
15
210
248139
g
30
4 x o 9o 13.5
c
130 210 210 210
a
l
IZM…3-…, IN…3-…
hambersrder to remove porting phase iso
rminaltchgear system donting in the syst
ersion only between the bus
125
130
35
g
k
130
Circ
uit-
brea
kfr
om 6
30 A
the arcing chamber. lation plates in the system
orem
bar and arcing space must be fitted on the system side
439
230
150 45
106
127
5.5
f
c
210
35
7632
7.5
150
30
275
130
20
451.
5541.
5
Moeller HPL0211-2007/2008
11/86
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rsfr
om 6
30 A
to
6300
ADimensionsOptional terminations
Optional terminations
Front connection (single hole fitting) IZM3-XATF... F 4000 A
Front connection (double hole fitting)
Vertical connection
130 210
50 50
160
c
421
160
ko 13.5
35
1145
1
82
20
47
6
c
130 210
50 50
160
o 13.5
82
20
47
34
541
6
c
85142
162
40
107
94.5 12
0330.
5
30
15
o 13.5
k
IZM3-XAT…
IZM
IZM
210 210
160 1
210 21
160 160
210
10
20
3-XATF... F 4000 A
3-XATV... F 5000 A
60
26
k
35
4042
14014
0
160
k
k
8080
210 210
11/87
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rsto
630
0 A
DimensionsOptional terminations
Standard version horizontal connection F 5000 A
57
590
800
160270j j
e
123.
527
5
466.
5
461
d nm
o
30
367.5
382.5
40.5
l
704
914
217270
260139
3030
o 13.5
57
160
85 210 210 210
160 160 160
630
840
Rated current Iu a4000 A 405000 A 406300 A 5
IZM…3-…, IN…3-…
k
3828
769
b210210245
Circ
uit-
brea
kfr
om 6
30 A
c Grooves (4 mm wide, 5 mm deep) for supporting phase isolation plates in the systemd Control circuit plug with screw terminalse Control circuit plug with spring-loaded terminalf Dimension for internal area of closed switchgear system doorj Fixing holes, o 10 mmk Connection areal Circuit-breaker upper edge - 1000 V AC version onlym IZM in connected positionn IZM in test positiono IZM in disconnected positionWhen front connections are used, a partition between the busbar and arcing space must be fitted on the system side
220 45
88.5
121.5
140.5
f
c
j
58
7632
7.5
150 3027
5
460
40 2031 27
42
517
o14
Moeller HPL0211-2007/2008
11/88
http://catalog.moeller.net
Circ
uit-
brea
kers
, sw
itch
-dis
conn
ecto
rsfr
om 6
30 A
to
6300
ADimensionsOptional terminations
Optional terminations
Front connection (single holle fitting) IZM3-XAT1F...-AV F 4000 A
Front connection (double hole fitting)
Vertical connection
Flanged connection
57
85 210
50 50
160
373
ko 13.5
35
20 62.5
169.5
1140
3
6
57
85
50
160
o 13.5
34
493
20 62.5
169.5
6
177
197
24
94.5 12
4.5
30
330.
5 o 13.5
k
38
57
a
85 210 21
30
57
590
80
91
160 160
704
5
121
IZM3-XAT…
IZM3
IZM3
210
160 160
590
800
210 210
50
160 1
590
800
590
8
b b
10
20
704
IZM3
0 210
0
4
160 160
-XATF...-AV F 4000 A
-XATV...-AV F 6300 A
-XATA...-AV F 4000 A
160
210
26k 35
60 160
210
4040
14
373
k
k
8080
914
00
210
59
26
o M12
142.
5 282.
5
59
33
11/89
http://catalog.moeller.net Moeller HPL0211-2007/2008
ers,
sw
itch
-dis
conn
ecto
rsto
630
0 A
DimensionsMeasuring transformers, voltage releases
Measurement transformer for N-conductor protection and earth-fault protectionIZM1-XW...
IZM2-XW...
IZM3-XW...
Voltage transformersfor IZM with measuring functionfor mounting on 35 mm top-hat rail
83
55 15
97
41
170
o 13.5
5144
68 130
24
91
36
8.9
2240
81 97
119
30 30
90
o 13.5
5144
68 130
24
91
30
160
30 30
o 13.5
184
5144
68 130
24
91
260 g3
IZM1, IZM2, IZM3
131
50.5
3 x 10
12
3 x 10
125 g
1
Circ
uit-
brea
kfr
om 6
30 A
60
70
83
170
88
113
95
119
65.5
54 115
131
170
3
52
161
160
184
3 31
45 107
123
87 g2