About This Manual P/N: 4710.01486A01 Product Model: E1 Release Date: January, 2018 Copyright © 2018 SonoScape Medical Corp. All rights reserved. Statement SonoScape Medical Corp. (hereinafter called SonoScape) owns the intellectual property rights to this manual, and also maintains the contents of this manual as confidential information. This manual is a reference for the operation, maintenance and cleaning of this product and does not convey any license under the patent rights of SonoScape, nor the rights of others. This manual contains the information protected by copyrights or patents. Reproduction, amendment or translation of this manual in any manner whatsoever without the written permission of SonoScape is strictly prohibited. All information contained in this manual is believed to be correct. SonoScape shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this manual. SonoScape does not assume any liability arising out of any infringements of patents or other rights of third parties. This manual is based on the maximum configuration and therefore some contents may not apply to your product. This manual is subject to change without prior notice and legal obligation. Manufacturer’s Responsibility SonoScape is responsible for the effects on safety, reliability and performance of this product, only if all the following requirements are met. All installation operations, expansions, changes, modifications and repairs of this product are conducted by SonoScape authorized personnel. The use or application of the product or the use of parts or accessories is approved by SonoScape. The electrical installation of the relevant room complies with the applicable national and local requirements. The product is used in accordance with the instructions for use. Documentation SonoScape provides the documentation consisting of various manuals: The basic user manual (this manual) describes the basic functions and operating procedures of the system.

Transcript of About This Manual Statement - Creche Innovations

Page 1: About This Manual Statement - Creche Innovations

About This ManualP/N: 4710.01486A01

Product Model: E1

Release Date: January, 2018

Copyright © 2018 SonoScape Medical Corp. All rights reserved.

StatementSonoScape Medical Corp. (hereinafter called SonoScape) owns the intellectual property rights to this manual, and also maintains the contents of this manual as confidential information. This manual is a reference for the operation, maintenance and cleaning of this product and does not convey any license under the patent rights of SonoScape, nor the rights of others.

This manual contains the information protected by copyrights or patents. Reproduction, amendment or translation of this manual in any manner whatsoever without the written permission of SonoScape is strictly prohibited.

All information contained in this manual is believed to be correct. SonoScape shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this manual. SonoScape does not assume any liability arising out of any infringements of patents or other rights of third parties.

This manual is based on the maximum configuration and therefore some contents may not apply to your product.

This manual is subject to change without prior notice and legal obligation.

Manufacturer’s ResponsibilitySonoScape is responsible for the effects on safety, reliability and performance of this product, only if all the following requirements are met.

● All installation operations, expansions, changes, modifications and repairs of this product are conducted by SonoScape authorized personnel.

● The use or application of the product or the use of parts or accessories is approved by SonoScape.

● The electrical installation of the relevant room complies with the applicable national and local requirements.

● The product is used in accordance with the instructions for use.

DocumentationSonoScape provides the documentation consisting of various manuals:

● The basic user manual (this manual) describes the basic functions and operating procedures of the system.

Page 2: About This Manual Statement - Creche Innovations

● The advanced user manual provides information about the measurements and calculations available in each mode.

● Compact Disc (CD) provides the acoustic output data related to the system. Understand the meanings of the following items clearly before reading this manual.

Item Meaning

!Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

Indicates a potentially hazardous situation which, if not avoided, may result in malfunction or damage of the system.

Indicates a potentially biological hazardous situation which, if not avoided, may result in disease transmission.

NOTE Indicates precautions or recommendations that should be used in operating the system.

BoldfacedWord

Indicates controls on the control panel, or on-screen objects such as menu items or keys.

Click Move the cursor to the controls on the display and press the confirm key on the control panel.

> Select a menu item or a key following the path.

Contact InformationManufacturer: SonoScape Medical Corp.

Address: 4/F, 5/F, 8/F, 9/F & 10/F, Yizhe Building, Yuquan Road, Nanshan, Shenzhen, 518051, Guangdong, China

Tel: +86 755 2672 2890

Fax: +86 755 2672 2850

http://www.sonoscape.com

E-mail: [email protected]

EU Representative: SonoScape Europe S.r.l.

Address: Via Luigino Tandura, 74-00128 Rome, Italy

Tel: +39 06 508 2160

Fax: +39 06 508 4752

http://www.sonoscapeurope.com

Page 3: About This Manual Statement - Creche Innovations

I

Contents

1    Safety ........................................................................................................................................ 1

1.1 Intended Use ............................................................................................................................2

1.2 Safety Precautions ...................................................................................................................2

1.2.1 Electrical Safety ............................................................................................................2

1.2.2 Mechanical Safety .........................................................................................................4

1.2.3 Accessories Caring ........................................................................................................4

1.2.4 Biohazard Considerations .............................................................................................5

1.3 Acoustic Power Principle ........................................................................................................5

1.3.1 Biological Safety...........................................................................................................6

1.3.2 ALARA .........................................................................................................................6

1.3.3 Mechanical and Thermal Indices ..................................................................................6

1.3.4 Probe Surface Temperature Limits ...............................................................................7

1.3.5 Imaging Functions that Change Acoustic Output .........................................................8

1.4 Safety Symbols ........................................................................................................................8

2    System Overview ................................................................................................................... 11

2.1 System Configuration ............................................................................................................12

2.2 Physical Specifications ..........................................................................................................12

2.3 System Components ..............................................................................................................12

2.3.1 Front Panel ..................................................................................................................13

2.3.2 Side View ....................................................................................................................14

2.3.3 Back View ...................................................................................................................15

2.3.4 Bottom View ...............................................................................................................15

2.3.5 Control Panel ..............................................................................................................16

2.3.6 Key Panel ....................................................................................................................19

2.3.7 Basic Screen ................................................................................................................21

3    Preparing the System ............................................................................................................ 23

3.1 Positioning the System .........................................................................................................24

3.2 Powering the System .............................................................................................................24

3.2.1 Using the Adaptor .......................................................................................................24

3.2.2 Using the Battery ........................................................................................................25

Page 4: About This Manual Statement - Creche Innovations

Contents

II

3.2.3 Installing/Removing the Battery .................................................................................26

3.2.4 Status Indicator ..........................................................................................................27

3.3 Powering On/Off the System.................................................................................................28

3.3.1 To Power On the System .............................................................................................28

3.3.2 To Activate Screen Saver ............................................................................................28

3.3.3 To Enter the Standby Mode ........................................................................................28

3.3.4 To Power Off the System ............................................................................................29

3.4 Adjusting the Brightness of the Monitor ..............................................................................29

3.5 Connecting the Probe ............................................................................................................29

3.6 Connecting the Peripheral Device .........................................................................................29

3.6.1 Connecting the Foot Switch (optional) .......................................................................29

3.6.2 Connecting the Printer ................................................................................................30

4    Customizing Your System ..................................................................................................... 33

4.1 General System Settings ........................................................................................................34

4.1.1 General Settings ..........................................................................................................34

4.1.2 Display Settings ..........................................................................................................36

4.1.3 Save Settings ...............................................................................................................38

4.1.4 Biopsy Settings ...........................................................................................................39

4.2 Exam Preset Settings .............................................................................................................41

4.3 Annotation Settings ...............................................................................................................42

4.3.1 Tools Settings ..............................................................................................................42

4.3.2 List Settings ................................................................................................................43

4.4 Body Mark Settings ...............................................................................................................44

4.5 Measurement Settings ...........................................................................................................45

4.5.1 General Measurement Settings ...................................................................................45

4.5.2 Application Settings ....................................................................................................47

4.5.3 List Settings ................................................................................................................50

4.6 Report Settings ......................................................................................................................51

4.7 Peripheral Devices Settings ...................................................................................................53

4.7.1 Basic Settings ..............................................................................................................53

4.7.2 Network Settings.........................................................................................................54

4.8 DICOM Settings ....................................................................................................................55

4.8.1 DICOM Service Settings ............................................................................................55

4.8.2 DICOM Local Settings ...............................................................................................64

Page 5: About This Manual Statement - Creche Innovations

Contents

III

4.9 Help Settings .........................................................................................................................65

4.10 Defining System Defaults ...................................................................................................65

4.10.1 Loading System Defaults ..........................................................................................65

4.10.2 Creating System Defaults .........................................................................................66

4.10.3 Exporting or Importing System Defaults ..................................................................66

4.11 Viewing System Information ...............................................................................................67

5    Preparing for an Exam ......................................................................................................... 69

5.1 Acquiring Patient Information ...............................................................................................70

5.1.1 Beginning a New Patient ............................................................................................70

5.1.2 Retrieving Archived Information ................................................................................72

5.1.3 Using DICOM Worklist ..............................................................................................73

5.1.4 Using Query/Retrieve List ..........................................................................................73

5.2 Pausing/Resuming/Completing an Exam ..............................................................................73

5.2.1 To Pause an Exam .......................................................................................................73

5.2.2 To Resume an Exam ...................................................................................................73

5.2.3 To Complete an Exam .................................................................................................74

6    Acquiring Images .................................................................................................................. 75

6.1 Selecting a Probe and an Exam Type ....................................................................................76

6.1.1 To Customize a Preset .................................................................................................76

6.1.2 To Arrange the Presets Display ...................................................................................77

6.2 Acquiring B-Mode Images ....................................................................................................78

6.2.1 Entering B Mode .........................................................................................................78

6.2.2 Optimizing B-Mode Images .......................................................................................78

6.3 Acquiring M-Mode Images ...................................................................................................83

6.3.1 M Mode.......................................................................................................................83

6.3.2 Optimizing M-Mode Images ......................................................................................85

6.4 Acquiring Spectral Doppler Images (Optional) .....................................................................87

6.4.1 PW Mode ....................................................................................................................87

6.4.2 Optimizing Spectral Doppler Images .........................................................................89

7    Working with Images ............................................................................................................ 93

7.1 Imaging Features ...................................................................................................................94

7.1.1 Imaging Reverse .........................................................................................................94

7.1.2 Split Screen Display....................................................................................................94

Page 6: About This Manual Statement - Creche Innovations

Contents

IV

7.1.3 Auto Optimization.......................................................................................................95

7.1.4 Harmonic Imaging .....................................................................................................96

7.1.5 Panoramic Imaging .....................................................................................................96

7.2 Magnifying an Image ............................................................................................................97

7.2.1 Filling the Full Screen.................................................................................................97

7.2.2 Magnifying the Whole Image .....................................................................................98

7.2.3 Magnifying the ROI ....................................................................................................98

7.3 Freezing an Image .................................................................................................................99

7.4 Using Cine .............................................................................................................................99

7.4.1 Reviewing Cine ..........................................................................................................99

7.4.2 Cutting Cine ................................................................................................................99

7.5 Annotations and Body Marks ..............................................................................................100

7.5.1 Annotating an Image with Typed Words ...................................................................100

7.5.2 Annotating an Image with Arrows ............................................................................100

7.5.3 Body Mark ................................................................................................................101

7.5.4 Deleting Annotations and Body Marks .....................................................................101

7.6 ECG Module........................................................................................................................102

8    Managing Images/Data ....................................................................................................... 105

8.1 Storing an Image/Cine .........................................................................................................106

8.1.1 Storing an Image ......................................................................................................106

8.1.2 Storing a Cine ...........................................................................................................106

8.2 Viewing an Image/Cine .......................................................................................................106

8.2.1 Viewing a Current Image/Cine .................................................................................106

8.2.2 Retrieving an Image ..................................................................................................108

8.3 Backing up Data ..................................................................................................................108

8.4 Importing Data to the System ..............................................................................................109

9    Working with DICOM .........................................................................................................111

9.1 Verifying Connectivity ........................................................................................................112

9.2 DICOM Storage ..................................................................................................................112

9.3 DICOM Print .......................................................................................................................113

9.4 DICOM Worklist .................................................................................................................113

9.5 Query/Retrieve List .............................................................................................................114

9.6 MPPS ...................................................................................................................................116

9.7 Storage Commitment ...........................................................................................................117

Page 7: About This Manual Statement - Creche Innovations

Contents

V

9.8 DICOM Queue ....................................................................................................................117

10    Probes and Biopsy Brackets  ............................................................................................ 119

10.1 Probe ..................................................................................................................................120

10.1.1 Available Probes......................................................................................................120

10.1.2 Probe Usage ............................................................................................................121

10.1.3 Cleaning the Probe ..................................................................................................123

10.1.4 Disinfecting or Sterilizing the Probe ......................................................................124

10.1.5 Sterilizing the Probe................................................................................................127

10.1.6 Disinfecting and Sterilizing the Probe Cable ..........................................................127

10.1.7 Storage and Transportation .....................................................................................128

10.2 Biopsy ................................................................................................................................129

10.2.1 Available Biopsy Brackets ......................................................................................129

10.2.2 Assembling the Biopsy Bracket ..............................................................................130

10.2.3 Preparing for a Biopsy ............................................................................................133

10.2.4 Verifying the Biopsy Bracket ..................................................................................133

10.2.5 Performing a Biopsy ...............................................................................................134

10.2.6 Cleaning the Biopsy Bracket ..................................................................................135

10.2.7 Sterilizing the Biopsy Bracket ................................................................................135

10.2.8 Storage ....................................................................................................................136

11    System Maintenance ......................................................................................................... 137

11.1 Cleaning the System ..........................................................................................................138

11.1.1 To Clean the System Surface ..................................................................................138

11.1.2 To Clean the Trackball ............................................................................................138

11.2 Maintenance Checks ..........................................................................................................139

11.2.1 Electrical Safety ......................................................................................................139

11.2.2 Battery Safety .........................................................................................................139

11.2.3 Mechanical Safety ...................................................................................................139

11.2.4 Image Recording .....................................................................................................139

11.3 Troubleshooting .................................................................................................................139

11.4 Equipment Disposal ...........................................................................................................140

11.5 Customer Service ...............................................................................................................140

Appendix  A  Specifications ..................................................................................................... 141

Appendix  B  EMC Guidance and Manufacturer’s Declaration ......................................... 142

Page 8: About This Manual Statement - Creche Innovations

Contents

VI

B.1 Electromagnetic Emissions .................................................................................................142

B.2 Electromagnetic Immunity .................................................................................................142

B.3 Recommended Separation Distances between Portable and Mobile RF Communications Equipment and the Equipment ...................................................................................................145

Appendix  C  In Situ, Derated, and Water Value Intensities ............................................... 146

Appendix  D  Recommended Coupling Gel, Cleaner and Disinfectant .............................. 147

D.1 Coupling Gel ......................................................................................................................147

D.2 Cleaner ................................................................................................................................148

D.3 Disinfectant .........................................................................................................................149

Appendix  E  Acoustic Output Data ....................................................................................... 150

Page 9: About This Manual Statement - Creche Innovations

1

1    Safety

This chapter describes the important information for operating this system. To ensure the safety of both operator and patient, please read the relevant details in this chapter carefully before using this system.

You should be thoroughly familiar with the precautions provided in this manual. Otherwise, the manufacturer is not responsible for the effects on safety, reliability and performance of the system.

Page 10: About This Manual Statement - Creche Innovations

1 Safety

2 Basic User Manual

1.1 Intended Use

The system is intended for the following applications: Fetal, Abdominal, Pediatric, Small Organ (breast, testes, thyroid), Cephalic (neonatal and adult), Trans-rectal, Trans-vaginal, Peripheral Vascular, Cerebral Vascular, Musculo-skeletal (Conventional and Superficial), Cardiac (pediatric and adult), OB/Gyn and Urology.

The system also provides the measurement and calculation packages used for clinical diagnosis purposes. For details, please refer to the advanced user manual.

Contraindication: The system is not intended for ophthalmic use or any use causing the acoustic beam to pass through the eye.

!Precautions must be considered in the use of any application. Otherwise, it may result in system damage or serious injury.

1.2 Safety Precautions

Read and understand all precautions in this manual before attempting to use the system. Keep this manual with the system at all times. Periodically review the procedures for operation and safety precautions.

1.2.1 Electrical Safety

! ● Only qualified physicians or sonographers can perform ultrasound scanning on human

subjects for medical diagnostic reasons.

● Any unauthorized personnel should not tamper with the main unit of the system.

● Do not service or maintain the system while it is in use with a patient.

● Do not position the system to make it difficult to disconnect the system from the mains supply.

● Do not use the system with flammable anaesthetics (category AP) or flammable anaesthetics with oxidants (category APG).

● Do not use the system with other equipment such as an electric knife, high-frequency therapy equipment, or a defibrillator. Otherwise, electrical shock may occur.

● Connect the protective earth conductor only before powering on the system. Disconnect the ground wire only after powering off the system. Otherwise, electrical shock may occur.

● Connect the system to the other electrical equipment by using the potential-equalization lead wire before connecting the power plug of the system to an electrical outlet.

● Do not place the multiple socket-outlet on the floor.

Page 11: About This Manual Statement - Creche Innovations

1 Safety

Basic User Manual 3

● The video printer should be connected to the specific interface by using the cable provided by the manufacturer. Otherwise, electrical shock may occur.

● Within the environment that is 1.8 meters (6 feet) around a patient, connect peripherals to the auxiliary power outlet which is capable of isolation protection; or, power the peripherals by the auxiliary output cable or the isolation transformer complied with EN/IEC 60601-1, or the power input of the same safety level.

● Within the patient environment, when removing the covers or the connectors from the non-medical electrical equipment without tools during maintenance, calibration or other operations, do not touch the parts of the non-medical electrical equipment and the patient simultaneously.

● Use only the probes provided by the manufacturer. Otherwise, the system will not perform, and an accident such as a fire may result in the worst case.

● Only the peripherals and accessories provided or recommended by the manufacturer can be used. Using other devices or accessories may degrade the system performance and even cause electrical shock.

● Do not pour any fluid onto the system surfaces, as fluid seepage into the electrical circuitry may cause excessive electrical current leakage or system failure. If any water is spilled onto the system carelessly, stop using the system and contact the local distributor immediately.

● The AC power plug for the system is a three-prong grounded plug and should never be adapted to any two-prong outlet or by using an adapter. Connect the AC power plug of the multiple socket-outlet to a hospital-grade power outlet.

● If the system is transported to the operating environment with a great temperature change, leave it for approximately 4 hours before powering it on. Ensure that the temperature and humidity inside and around the system are equivalent before an operation.

● Do not use the system around a strong electric field, a strong electromagnetic field, or the devices which generate radio waves, such as a radio, cellular telephones, or transceivers. Using the system in an improper environment may result in malfunction or damage.

● Select the conformed multiple socket-outlet with protective grounding, and ensure that its maximum output power exceeds the requirement of the system.

● The multiple socket-outlet can only be used to provide power to the recommended peripherals of the system.

● Do not connect other devices to the multiple socket-outlet. Otherwise, the rated output power of the multiple socket-outlet may be exceeded, and it may result in failure.

Page 12: About This Manual Statement - Creche Innovations

1 Safety

4 Basic User Manual

● Accessory equipment connected to the analog and digital interfaces must be certified according to the respective EN/IEC standards (for example, EN/IEC 60950 for data processing equipment and EN/IEC 60601-1 for medical equipment). Furthermore, all configurations shall comply with the system standards EN/IEC 60601-1.

● Do not use an endocavitary probe on the body surface of a patient. Otherwise, the electromagnetic compatibility of the probe may be degraded.

● If the non-medical electrical equipment used with the system is supplied by a multiple socket-outlet with separating transformer, connect the AC power plug of the multiple socket-outlet to a hospital-grade power outlet. Consult a professional to ensure that the connection complies with the safety standards.

1.2.2 Mechanical Safety

! ● To avoid possible personnel injury and system damage, move the system slowly and

carefully.

● Do not place other objects on top of the control panel. Do not sit on the control panel or any other part of the system.

● Disconnect the foot switch and the power cable before moving the system.

● Do not knock or shake the system.

● Always use the handle to move the system.

1.2.3 Accessories Caring

! ● Do not use the foot switch in the operating room.

● Use the probe carefully. If any part of the transducer surface is scratched, stop using the probe immediately. Otherwise, electrical shock may occur.

● After disinfecting the accessories, wash out chemicals or discharge gases thoroughly from the accessories. Residual chemicals or gases could result in damage to the accessories, and be harmful to human bodies.

● Only trained physicians or sonographers under ultrasound guidance can handle the biopsy needle guides. During the operation, the operator must observe proper needle insertion sequencing with the needle guide to avoid undue discomforts, unnecessary risks or injuries to the patient.

● Use the legally marketed probe sheath. Refer to package labeling to determine latex content. Natural rubber latex may cause anaphylactic reactions in some individuals. Avoid contact with items containing natural rubber latex. Refer to the FDA Medical Alert, March 29, 1991.

Page 13: About This Manual Statement - Creche Innovations

1 Safety

Basic User Manual 5

● Use the legally marketed coupling gel in accordance with relevant local regulations. Read and understand all precautions in the relevant manual of the coupling gel before use.

● Prepare, use, store and dispose the cleaner, disinfectant and sterilant according to the instructions provided by manufacturers.

● Do not disconnect the probe during the real-time scan. Otherwise, it may damage the probe and the system.

● Disconnect the probe from the system after freezing an image or powering off the system. Otherwise, the system or the probe could be damaged.

1.2.4 Biohazard Considerations

● To minimize the risk of cross-contamination or infectious diseases when performing a biopsy, the operator should wear disposable gloves, protective clothing or protective goggles if it is needed. Follow the working regulations strictly in case the skin contacts the samples.

● Some disinfectants or sterilants are acid or alkaline. Use them with caution, and prevent hands or clothing from coming into direct contact with them. Wash hands or eyes immediately in case of any contamination by disinfectants.

● Dispose of cleaners, disinfectants or solutions in accordance with local standards or regulations.

1.3 Acoustic Power Principle

! ● Perform ultrasound procedures prudently under the guidance of the ALARA (as low

as reasonably achievable) principle. Only expose the patient to the lowest practical transmit power levels in the shortest possible period to achieve a satisfactory diagnosis.

● Freeze the image at any time if you are not operating the system for a long period of time.

● Do not scan the same part of an patient continuously or expose the patient to prolonged scanning. Doing so may harm the patient.

● Do not expose the fetus to prolonged scanning in the Doppler mode.

● Although the output power is automatically controlled for the selected applications, high TI values should be kept to a minimum or avoided in obstetric applications.

● You should be familiar with the performances and operations of the system, observe the ultrasound output parameters on the screen at all times.

Page 14: About This Manual Statement - Creche Innovations

1 Safety

6 Basic User Manual

1.3.1 Biological Safety

Diagnostic ultrasound is recognized as being safe, but the possibility of biological effects exists when using it in high exposure levels and long exposure times. Thus ultrasound should be used in a prudent manner to provide medical benefit to the patient.

1.3.2 ALARA

It is required to practice ALARA when using ultrasound energy. Practicing ALARA ensures that the total energy level is controlled below a low enough level at which bioeffects are not generated while diagnostic information is being accumulated. The total energy is controlled by output intensity and total radiation time. The output intensity necessary for examinations differs depending on the patient and the clinical case.

Not all examinations can be performed with an extremely low level of acoustic energy. Controlling the acoustic level at an extremely low level leads to low-quality images or insufficient Doppler signals, adversely affecting the reliability of the diagnosis. However, increasing the acoustic power more than necessary does not always contribute to an increase in quality of information required for diagnosis, rather increasing the risk of generating bioeffects.

The operator must take responsibility for the safety of the patients and utilize the ultrasound deliberately. Deliberate use of the ultrasound means that output power of the ultrasound must be selected based on ALARA. Additional information regarding the concept of ALARA and the possible bioeffects of Ultrasound is available in a document from the AIUM (American Institute of Ultrasound Medicine) title “Medical Ultrasound Safety”.

1.3.3 Mechanical and Thermal Indices

The display of the system consists of two parts: Thermal Index (TI) and Mechanical Index (MI).

■  MI/TI Explanation

In October 1987, the American Institute of Ultrasound in Medicine (AIUM) ratified a report prepared by its Bioeffects Committee (Bioeffects Considerations for the Safety of Diagnostic Ultrasound, J Ultrasound Med.,Sept. 1988: Vol. 7, No. 9 Supplement), sometimes referred to as the StoweReport, which reviewed available data on possible effects of ultrasound exposure. Another report “Bioeffects and Safety of Diagnostic Ultrasound” dated January28, 1993, provides more current information.

● Mechanical Index (MI)

Page 15: About This Manual Statement - Creche Innovations

1 Safety

Basic User Manual 7

Mechanical bioeffects are threshold phenomena that occur when a certain level of output is exceeded. The threshold level varies, however, with different types of tissue. The potential mechanical bioeffects varies with peak pressure and ultrasound frequency. The MI accounts for these two factors. The higher the MI value, the greater the likelihood of mechanical bioeffects occurring. There is no specific MI value that means that a mechanical effect is actually occurring. The MI should be used as a guide for implementing the ALARA principle.

● Thermal Index (TI)

The TI value informs the operator about the conditions that might lead to an increase in temperature on the surface of the body, within the body tissue, or at the point of focus of the ultrasound beam on bone. That is, the TI value informs the operator about the potential temperature rise in body tissue. It is an estimate of temperature increase in body tissue with specific properties. The actual amount of any temperature rise is influenced by factors such as tissue type, vascularity, mode of operation and others. The TI value should be used as a guide for implementing the ALARA principle.

Depending on the examination and type of tissue involved, TI could be one of three types:

− Soft Tissue Thermal Index (TIS) is used when imaging soft tissue only, it provides an estimate of potential temperature rise in soft tissue.

− Bone Thermal Index (TIB) is used when bone is near the focus of the image as in the trimester, it provides an estimate of potential temperature rise in the bone or adjacent soft tissue.

− Cranial Bone Thermal Index (TIC) is used when bone is near the skin surface as in transcranial examination, it provides an estimate of potential temperature rise in the bone or adjacent soft tissue.

■  MI/TI Display

TI and MI values are displayed in the real time scan on the screen. The operator should observe these index values during examinations and ensure that exposure time and output values are maintained at the minimum amounts needed for effective diagnosis.

The MI and TI precision is 0.1.

1.3.4 Probe Surface Temperature Limits

For probes intended for internal applications, e.g. the endocavitary probe or transesophageal probes, the surface temperature of the probe may change by adjusting system parameters.

Page 16: About This Manual Statement - Creche Innovations

1 Safety

8 Basic User Manual

The maximum surface temperature of the endocavitary probes is 43°C. To protect the patient against the harm of excessive temperature, the probe stops working automatically when its temperature reaches the limit. The surface temperature of the probe is displayed on the screen.

PAT 37°C Patient Temperature

Transducer Tip TemperatureTIP <28°C

1.3.5 Imaging Functions that Change Acoustic Output

The qualified operator may use the system controls to limit the ultrasound output and to adjust the quality of the images. The operator should observe the acoustic output display for possible effects.

There are three categories of system controls relative to output. They are controls that have direct effect on the output, controls that indirectly control output and controls that are receiver controls.

1.4 Safety Symbols

The following table is provided for your identification of important symbols located in labels on the system.

Symbol Meaning

Caution

Dangerous voltage

Risk of explosion if used in the presence of flammable anesthetics.

0197This product is provided with a CE marking in accordance with the regulations stated in Council Directive 93/42/EEC

Authorized representative in the European community

Type BF Applied Part

Power On/Off button

Page 17: About This Manual Statement - Creche Innovations

1 Safety

Basic User Manual 9

Symbol Meaning

Alternating current

Direct current

Degree of IP protection

Non-ionizing electromagnetic radiation.

Manufacturer

Date of manufacture

Follow instructions for use

Network Port

USB Port

Fragile

AUDIO output

Keep dry

Maximum stacking limit of packages

Maximum of two layers allowed for the system

Keep this way upward

Page 18: About This Manual Statement - Creche Innovations

1 Safety

10 Basic User Manual

Symbol Meaning

Serial Number

Use it in ventilated and dry indoor environment (for AC adaptor only)

Rechargeable (for battery only)

This symbol indicates that waste electrical and electronic equipment must not be disposed of as unsorted municipal waste and must be collected separately. Please contact an authorized representative of the manufacturer for information concerning the decommissioning of your equipment.

Page 19: About This Manual Statement - Creche Innovations

11

2    System Overview

This system adopts advanced ultrasonic Doppler technologies.

To ensure the performance and availability of this system, you should be thoroughly familiar with the operations of system components, the control panel, the key panel and the basic screen.

Page 20: About This Manual Statement - Creche Innovations

2 System Overview

12 Basic User Manual

2.1 System Configuration

The standard system configuration mainly consists of the followings items:

● Main unit

● Probes

● Others: See the Packing List in the packaging box.

2.2 Physical Specifications ● LCD monitor: 15.6’’ color display

● System dimensions: approx. 378mm(W) × 352mm(H) × 114mm(D)

● System weight: approx. 6.5kg (at most, including battery)

2.3 System Components

Figure 2-1 System Overview

Page 21: About This Manual Statement - Creche Innovations

2 System Overview

Basic User Manual 13

2.3.1 Front Panel

3

2

1

4

65

Figure 2-2 Front View

1 Handle 4 Control panel

2 Probe holder 5 Indicators

3 LCD monitor 6 Release latch

Page 22: About This Manual Statement - Creche Innovations

2 System Overview

14 Basic User Manual

2.3.2 Side View

1

2

34567 8

Figure 2-3 Side Views

1 HDMI video output port 5 Print control port

2 USB port 6 S-Video output port

3 Audio output port 7 Network port (DICOM)

4 Audio input port 8 Power on/off button

Page 23: About This Manual Statement - Creche Innovations

2 System Overview

Basic User Manual 15

2.3.3 Back View

1

3

45

78

6

2

Figure 2-4 Back View

1 Ventilation holes 5 Foot switch port

2 Cable hanger holder (optional) 6 AC adaptor port

3 Probe port 7 Video output port

4 ECG port (optional) 8 Grounding terminal

2.3.4 Bottom View

1

2

Figure 2-5 Bottom View 

1 Battery lock 2 Battery

Page 24: About This Manual Statement - Creche Innovations

2 System Overview

16 Basic User Manual

2.3.5 Control Panel

1

2

34

56

7

89

10

11

12 13 14 15 16 17 18 1920

2122

23 24 25 26 27 28

29

303132

33

34

35

37 36

Figure 2-6 Control Panel

No. Name Description

1 Probe Select the corresponding exam type.

2 Patient Enter the New Patient screen.

3 Report Enter the Measurement Report screen.

4 Review Display the Patient Exam List screen.

Or, to enter the Review Exam screen after creating a new patient exam.

5 End Exam End the current real-time examination.

6 Key Panel Use it to enter patient information. For details, refer to Section 2.3.6 Key Panel.

7 Baseline Adjust the position of the baseline in the PW mode.

8 Scale Adjust the velocity scale.

Page 25: About This Manual Statement - Creche Innovations

2 System Overview

Basic User Manual 17

No. Name Description

9 Angle ● Adjust the flow direction in the PW mode.

● Adjust the arrow direction when the arrow annotation feature is activated.

● Adjust the measurement angle of the hip joint when performing the HIP measurement.

10 P1 Save images. Or, the function of this key can be set as required. For details, refer to Section 4.1.3 Save Settings.

11 P2 Save screenshot. Or, the function of this key can be set as required. For details, refer to Section 4.1.3 Save Settings.

12 Body Mark ● Press it to add body mark on an image.

● Rotate it to adjust the probe mark direction if the body mark annotation feature is activated.

13 Annot Annotate an image with typed words.

14 Clear Remove all measurement results, annotations, arrows and body mark from the display.

15 Pointer Activate the trackball cursor.

16 Confirm Key

Confirm the current operation.

17 Calc Activate the application-specific measurement and calculation features.

18 Trackball Move the cursor and adjust ROI.

19 Update ● Enter the M/PW mode in an inactivated M/PW mode.

● Switch between measurement markers when performing distance or ellipse measurement.

● Undo the trace when performing a trace measurement.

● Select the interest area when the zoom feature is activated.

20 Caliper Activate the basic measurement and calculation features.

21 Confirm Key

Confirm the current operation.

22 ● Activate dual-split screen display.

● Switch between two images in dual-split display.

Page 26: About This Manual Statement - Creche Innovations

2 System Overview

18 Basic User Manual

No. Name Description

23 Freeze Freeze the image in the real time mode or restore the real time scan.

24 M Enter or exit the M mode.

PW Enter or exit the PW mode.

CFM Reserved

B Enter the B mode.

25 Auto/Gain ● Press it to automatically optimize an image.

● Rotate it to adjust the gain of the current mode.

26 Standby Indicator

Indicates the system standby status.

27 Charging Indicator

Indicates the battery charging status. For details, refer to Section 3.2.4 Status Indicator.

28 Discharging indicator

Indicates the battery discharging status. For details, refer to Section 3.2.4 Status Indicator.

29 Image Save an image in the real time mode or frozen mode.

30 Cine ● The function of this key can be set through the system.

● The cine storage is the default function. For details, refer to Section 4.1.3 Save Settings.

31 Print Print the current screen displayed on the monitor.

32 Depth Adjust the scan depth.

33 Zoom ● Press it to activate or exit the zoom feature.

● Rotate it to magnify the interest area of the ultrasound image.

34 Focus Adjust the focus position.

35 TGC Adjust the TGC settings at different scan depth.

36 NEXT Key ● This key corresponds to the function key located at the bottom of the screen.

● Press it to go to the next or previous page.

Page 27: About This Manual Statement - Creche Innovations

2 System Overview

Basic User Manual 19

No. Name Description

37 Function Keys

● These six function keys corresponds to the menu items located at the bottom of the screen.

● Press it to select the corresponding menu item.

● Rotate it to set the selected menu item.

2.3.6 Key Panel

1 102 3 4 5 96 7 8 11 12 1413

16

192021 18 17

15

Figure 2-7 Key Panel

No. Name Description

1 Esc Exit the System Settings screen or New Patient screen.

2 Help Reserved

3 F3The function of this shortcut key can set through the system. The screenshot storage is default functions. For details, refer to Section 4.1.3 Save Settings.

4 F4The function of this shortcut key can set through the system. The image print is default functions. For details, refer to Section 4.1.3 Save Settings.

5 3D Reserved

6Activate quad-split screen display.

Switch among four images in quad-split display.

7 Reverse an image up or down.

Page 28: About This Manual Statement - Creche Innovations

2 System Overview

20 Basic User Manual

No. Name Description

8 Reverse an image left or right.

9 Pan Press it to enter panoramic mode

10 PDI Reserved

11 TDI Reserved

12 CW Reserved

13 ECG Enable or disable the ECG feature.

14 Del

● Delete the selected annotation, arrow or body mark when annotating an image.

● Delete the selected measurement marker and result when performing a manual trace measurement or other measurement.

15 Biopsy Enable or disable the biopsy feature.

16Up/Down/Left/

Right Arrow

Used in conjunction with the Shift key to adjust the volume of PW mode and the brightness of display.

17 THI Enter or exit the THI mode.

18 MenuActivate the menu area when ECG or biopsy feature is activated.

19 Space Enter a space.

20 Setup Enter the System Settings screen.

21 Arrow Add arrows to an image.

Page 29: About This Manual Statement - Creche Innovations

2 System Overview

Basic User Manual 21

2.3.7 Basic Screen

3

6 51012 78911

21

SonoscapeNew hosp.

XXX

XXXXX

MI 0.2女 XXXXXX TIS 0.732Dr Ng Kit Lenug

2014-11-06 10:39AM 19700101_203151

0

5

10

15

NEXT

7.5 4/20

1/1P

1

2

3

4

Cine

s

415

16

13

14

Frequncy3.7-4.5

Line DensityMed

Gray Map2

ChromaOff

μScan3

PersistLow

DR140

Power100%

Sector Width/Angle100%

Focus Area3

WidescanOff

Compond1

Figure 2-8 Basic Screen 

1 Manufacturer logo

2 Information bar

3 Status bar

4 Clipboard

5 NEXT key

6 Cine loop icon (in frozen mode)

7 Measured result box

8 Imaging area

9 Cine loop status (in frozen mode)

10 Imaging parameters

11 Parameter value/level

12 Advanced function keys

13 Depth scale and focal position

14 Imaging information

15 Measurement parameter/annotation box/menu area

16 Grayscale map

Page 30: About This Manual Statement - Creche Innovations

T h i s p a g e i s i n t e n t i o n a l l y l e f t b l a n k .

Page 31: About This Manual Statement - Creche Innovations

23

3    Preparing the System

System preparation is necessary before using the system. The preparation includes but is not limited to positioning and adjusting the system, connecting the probe and the peripheral devices.

Page 32: About This Manual Statement - Creche Innovations

3 Preparing the System

24 Basic User Manual

3.1 Positioning the System 

Leave at least 20cm at the back and both sides of the system for ventilation. Otherwise, the temperature rise could cause failures.

Place this system on a level surface.

You can place the system on the trolley (sold separately) provided by manufacturer. For details on installing the system to the trolley, please refer to the relevant user manual.

3.2 Powering the System

AC adaptor and rechargeable battery can be used to provide power for the system.

3.2.1 Using the Adaptor

! ● The accompanying adaptor can only be used for power supply or battery charge of the

system. Other usages may damage the adaptor or even cause an electrical shock.

● Ensure that the adaptor is not damaged before use. If damage exists, stop using it immediately and contact the manufacturer or the local distributor.

● Use only the adaptor provided by the manufacturer.

● Do not hang the adaptor in the air.

● The adaptor should be placed in a well ventilated area during use. Do not cover the adaptor with any other objects.

Perform the following steps to connect the adaptor

1. Place the connector as shown in Figure 3-1 and connect the adaptor to the system firmly.

Sliding block

This surface faces upwards.

Figure 3-1 Adaptor Connector

Hold and pull the sliding block to disconnect the adaptor.

2. Connect the other end of the adaptor to the mains supply firmly.

Page 33: About This Manual Statement - Creche Innovations

3 Preparing the System

Basic User Manual 25

3.2.2 Using the Battery

! ● Do not disassemble or alter the battery. Otherwise, there is a danger of explosion.

● Replace the battery with the type recommended by the manufacturer.

● Install/Remove the battery only when the system is powered off.

● Do not short-circuit the battery by directly connecting the system with metal objects.

● If the battery emits an odor or heat, is deformed or discolored, or appears abnormal during use, charging or storage, remove it and stop using it immediately. If you have any questions about the battery, please contact the manufacturer.

● Do not use the battery if it leaks. If your skin or clothing is stained with the fluid from the battery, thoroughly wash the area immediately with clean water. If the fluid comes into contact with your eyes, immediately flush your eyes with water and seek an oculist for help.

● If the battery is damaged, severely degraded or used for 3 years, dispose of it in accordance with local laws or regulations.

If the system is connected to the mains supply with the adaptor, the battery is charged automatically. If the adaptor is disconnected, the system is powered by the battery.

A fully charged battery can work continuously for more than one hour. The specifications of the battery are as follows.

● Nominal voltage: 14.4V

● Capacity: 6.2Ah/89.28Wh

!To avoid battery damage causing system damage, observe the following precautions:

● Do not immerse the battery in water or allow it to get wet.

● Do not discard the battery in a fire.

● Do not expose the battery under the sunlight or leave it in the environment over 60°C.

● Keep the battery away from fire and other heat sources during use and charge.

● Do not pierce the battery with a sharp object, hit or step on it.

● Do not place the battery into a microwave oven or other pressure vessels.

Page 34: About This Manual Statement - Creche Innovations

3 Preparing the System

26 Basic User Manual

● Only use the battery if there is an emergency or no reliable AC power supply. It is recommended to use the AC supply instead of the battery.

● If you do not attempt to use the battery within 3 months, fully charge the battery and store it in the temperatures of -20°C to 45°C. If the battery has been stored for more than 3 months, it is recommended to charge the battery at least once every 3 months to avoid liquid leakage.

● Charge the battery in the temperature of 0°C to 45°C and discharge it in the temperature of 0°C to 60°C to prolong the service life of the battery.

● When the battery capacity is low and the battery cannot be charged in time, you should save the data before system shutdown to avoid data loss.

3.2.3 Installing/Removing the Battery

■  To Install the Battery 

Install the battery into the battery compartment as shown in the following figure. If it is installed in place, a click will be heard.

■  To Remove the Battery

Switch the battery lock to the position and take out the battery, as shown in the following figure.

Page 35: About This Manual Statement - Creche Innovations

3 Preparing the System

Basic User Manual 27

3.2.4 Status Indicator

The status indicators are located on the control panel to indicate the battery charging and discharging statuses. When the system is powered on, you can move the cursor onto the battery icon by using the trackball to view the current battery capacity. The battery icon is displayed in the status bar.

The description of status indicators are as shown in Table 3-1.

Table 3-1 Status Indicator

Status Indicators

Mains SupplyBattery 

With Battery Without Battery

(charge)

Lights in green when fully charged.

Lights in yellow during charge.

Lights in green.

Off

(discharge) Off Off

Lights in green: 90%-100%

Lights in yellow: 5%-90%.

Off: less than 5% (the system shuts down automatically.)

Page 36: About This Manual Statement - Creche Innovations

3 Preparing the System

28 Basic User Manual

3.3 Powering On/Off the System

● Do not power off the system during system upgrade or a data transmission.

● An extra 30-60 seconds are needed for powering on the system if it is powered off in an abnormal way previously.

● Do not forcibly power off the system during system operation. Otherwise, it may cause permanent damage to the system or data loss.

● Wait approximately 20 seconds before powering on the system again after powering off. Otherwise, a failure may result.

● To maintain the safety and functionality of the system, regular maintenance must be performed as described in 11 System Maintenance.

● Ensure the system works in accordance with requirements in Appendix A Specifications.

3.3.1 To Power On the System

Press the button on the control panel of the system to power on the system.

3.3.2 To Activate Screen Saver

If the system is idle for a set period of time, the system enables the screen saver automatically. Press any key to exit the screen saver. For details, refer to Section 4.1.2 Display Settings.

3.3.3 To Enter the Standby Mode

Perform one of the following ways.

● Press the button and click Standby on the pop-up menu to enter the standby mode.

Press the button in the standby mode to exit the standby mode. ● Close the upper cover of the system, and the system automatically enters the standby

mode.

Open the upper cover of the system, and the system automatically exits the standby mode.

● Set automatical standby time. If the system is idle for a set period of time, the system will automatically enter the standby mode. For details, refer to Section 4.1.2 Display Settings.

Press the button in the standby mode, and the system automatically exits the standby mode.

Page 37: About This Manual Statement - Creche Innovations

3 Preparing the System

Basic User Manual 29

3.3.4 To Power Off the System

Press the button and select Shutdown on the pop-up menu to power off the system.

3.4  Adjusting the Brightness of the Monitor

Press Shift and the up/down arrow keys to adjust the brightness.

3.5 Connecting the Probe

Disconnect the probe from the system after freezing an image or powering off the system. Otherwise, the system or the probe could be damaged.

Perform the following steps.

1. Put the cable leftwards, rotate the locking lever anticlockwise to the position, and then insert the probe connector into the probe port firmly.

2. Rotate the locking lever to the position to lock the probe firmly.

3.6 Connecting the Peripheral Device

3.6.1 Connecting the Foot Switch (optional)

● To avoid damaging the foot switch, do not place the foot switch on the ultrasound system.

● Use only the foot switch provided by the manufacturer. Otherwise, the ultrasound system or the foot switch may be malfunctioning.

Connect the foot switch to the foot switch port of the ultrasound system as the figure shows below.

Page 38: About This Manual Statement - Creche Innovations

3 Preparing the System

30 Basic User Manual

Used for image freezing

Used for printing

Ultrasound system

Foot SW

3.6.2 Connecting the Printer

Video printer, Window printer and USB printer recommended by the manufacturer can be connected to the system.

■  Video Printer

Connect a video printer to the system.

VIDEO OUT

PRINT REMOTE

VIDEO INPUT

Ultrasound system Video printer

The printer can work without any configurations after a successful connection.

■  Windows Printer 

Perform the following steps.

1. Connect the system to the local network of the computer by using a network cable.

2. Install the driver file Setup-PrinterProxy-2.1.exe provided by the manufacturer on the computer.

3. Press the Setup key to enter the System Settings screen and click Peripheral > Basic.

Page 39: About This Manual Statement - Creche Innovations

3 Preparing the System

Basic User Manual 31

4. Set Default Printer to Windows Printer, input the IP address of the desired computer, and set the Printer Port Number to 6050.

NOTE:• IP address of the computer and the system should be set in the same network

segment.

• Ensure that a printer is available for the computer.

5. Click Apply.

The printer can work without any configurations.

■  USB Printer

Perform the following steps.

1. Connect the system to the USB printer by using a USB cable.

2. Copy the file deskjet.ppd provided by the manufacturer to the USB drive.

3. Insert the USB drive into the USB port of the system.

4. Press the Setup key to enter the System Settings screen and click Peripheral > Basic.

5. Set Default Printer to USB Printer, and click Adding Printer  to connect. The printer can be used after successfully connected.

Page 40: About This Manual Statement - Creche Innovations

T h i s p a g e i s i n t e n t i o n a l l y l e f t b l a n k .

Page 41: About This Manual Statement - Creche Innovations

33

4    Customizing Your System

The System Settings menu allows you to specify the operating status, system date and time, monitor brightness, etc. All your customized settings can remain even after rebooting the system.

Page 42: About This Manual Statement - Creche Innovations

4 Customizing Your System

34 Basic User Manual

After you power on the system, the LCD monitor displays the Application Mode screen. Press the Setup key on the key panel to enter the System Settings menu.

To make settings on the System Settings menu,

● Select one tab to enter a settings menu.

● Move the cursor to a text box beside an item and use the key panel to manually type the value.

● Select an option from each drop-down list.

● Click Load Defaults to restore the factory settings.

● Click Apply to save any changes.

● Click Exit to exit the System Setting menu.

4.1 General System Settings

You can make general system settings on the General, Display, Save and Biopsy tab.

4.1.1 General Settings

Exam Preset

Comment

Bodymark

Measure

Report

Peripheral

General

3

Medical

2015/01/07 16:00:00

DICOM

Help

Load Default

About

Apply

Biopsy

24

SystemSettings

Exit

General Display Save

Hospital Name

Freeze Response

End Exam Response

Trackball Sensitivity

Cine

Scan

Language and Time

LanguageTime Zone

English

(GMT+08:00) Beijing, Chongqing, Hong Kong, Urumqi

Set Time

Current System Time: Date/Time Setting

Date Format: Time Format:

YYYY/MM/DDMM/DD/YYYYDD/MM/YYYY

Load Defaults

Figure 4-1 General Settings Menu - General Tab

Page 43: About This Manual Statement - Creche Innovations

4 Customizing Your System

Basic User Manual 35

Item Description

Hospital Name Enter the institution’s name.

End Exam Response Select the feature to be enabled after you press the End Exam key.

Trackball Sensitivity Adjust the sensitivity for the trackball movement. A greater value brings about a higher sensitivity.

Language Choose a system language for the user interface.

NOTE:Reboot the system for the system to take effect after choosing a system language.

Time Zone Set the local time zone.

Date/Time Setting Select this item to set the system date and time manually in the pop-up text box.

NOTE:You should set the system date and time for your initial use of the system.

Date Format Set the date format for the system.

Time Format Set the time format for the system.

Page 44: About This Manual Statement - Creche Innovations

4 Customizing Your System

36 Basic User Manual

4.1.2 Display Settings

Width Ruler

LGC

On

Ivory

15

On

30

0 100

0 100

Show Gallery

SystemSettings

Exam Preset

Comment

Bodymark

Measure

Report

Peripheral

General

DICOM

Help

Load Default

About

Apply

Exit

General Display Save Biopsy

System Sleep

Screen Saver Wait

System Standby

Key Volume

Volume

Min

Min

Brightness&Colors

Auto

Keyboard

Monitor

Colors

Monitor Colors Warm

Off

Trackball

Light color

Show Gallery

Load Defaults

On

Off

Auto Wait

Keyboard & Monitor Brightness

Figure 4-2 General Settings Menu - Display Tab

Item Description

Screen Saver Set the period to activate the screen saver.

Auto Standby Set the wait time of entering the auto standby mode.

LGC Enable or disable the LGC feature.

Width Ruler Enable or disable the display of the width ruler.

Key Volume Enable or disable the key tone.

Trackball Color Set the backlight color of the trackball.

Keyboard & Monitor Brightness

Set the brightness of the keyboard and the monitor,

Monitor Colors Set the color temperature of the monitor.

Show Gallery View images and cines coming with the system or imported from external storage devices.

Page 45: About This Manual Statement - Creche Innovations

4 Customizing Your System

Basic User Manual 37

■  Show Gallery

Perform the following steps to perform a demonstration.

1. Click Show Gallery to enter the Show Gallery screen, as shown in Figure 4-3.

.

Play Interval

4 seconds

Show GalleryTop

Up

Down

Bottom

Import

Load Default

Delete

Exit

Figure 4-3 Show Gallery Screen

2. Load default demos or import demos from an external storage device.

− Select a demo and click Top, Up, Down or Bottom to arrange the order. − Select a demo and click Play Interval from the drop-down list to set the interval of demo playing.

− Select a demo and click Delete to remove it from the gallery.3. Select a demo and press the confirm key twice on the control panel to start a

demonstration.

− Press the Up/Down/Left/Right arrow key to go to the previous or next demo. − Press the confirm key to pause or resume the demonstration. − Press the button to stop the demonstration.

Page 46: About This Manual Statement - Creche Innovations

4 Customizing Your System

38 Basic User Manual

4.1.3 Save Settings

Save Format/Area

P1

P2F3

F4

Cine

AVI

JPG

Low NoneHighSave SoundSend cine to DICOM storage

Time s

retrospective storeprospective store

prospective store

Time s s

Freeze Store

SystemSettings

Exam Preset

Comment

Bodymark

Measure

Report

Peripheral

General

DICOM

Help

Load Default

About

Apply

Exit

General Display Save Biopsy

120 Time

Save Operation

Send image to DICOM storage

Load Defaults

Save Image

Save Cine

Screen Shot

Print Image

AreaCine

Image

ImageArea+InfoBar

Key Function

Figure 4-4 General Settings Menu - Save Tab

Item Description

P r o s p e c t i v e Store

Set the time span for the prospective storage of the cine.

Retrospect ive Store

Set the time span for the retrospective storage of the cine.

Freeze Store Set the time span for cine storage in the frozen mode.

Area Set the area to be saved.

Cine Set the cine storage format.

Image Set the image storage format.

Key Function Set the functions for the shortcut keys P1, P2, F3, F4 or Cine.

Send image to DICOM storage

Tick it, the system sends an image to the DICOM storage server every time the image is saved.

Page 47: About This Manual Statement - Creche Innovations

4 Customizing Your System

Basic User Manual 39

Item Description

S e n d c i n e t o DICOM storage

Tick it, the system sends a cine to the DICOM storage server every time the cine is saved.

Save Sound Set the volume level of the storage tone.

4.1.4 Biopsy Settings

3C-AL7413P-AC6136V1

12°45°14°12°3°

C322 5°EC9-5 1.5°

Exam Preset

Comment

Bodymark

Measure

Report

Peripheral

General

DICOM

Help

Load Default

About

Apply

Exit

General Display Save Biopsy

Biopsy Guide Line Biopsy Grid

Bracket

Probe Type Biopsy

Biopsy Parameters

Guide Line Type

Guide Line Display

Line

On

Load Defaults

SystemSettings

Figure 4-5 General Settings Menu - Biopsy Tab

■  Biopsy Guideline

Item Description

Biopsy Set the default biopsy angle for the probe.

Page 48: About This Manual Statement - Creche Innovations

4 Customizing Your System

40 Basic User Manual

Item Description

Guide Line Type Select a type for the biopsy guideline.

● Set it to Line, and one biopsy guideline is displayed when performing a biopsy.

● Set it to Range, and two parallel biopsy guidelines are displayed when performing a biopsy. The two guidelines make up the guide zone within which is used to guide a safe biopsy.

Guide Line Display Hide or display the biopsy guideline.

■  Biopsy Grid

Item Description

Biopsy Grid Display Style Set the display style of the biopsy grid.

Biopsy Grid Display Color Set the display color of the biopsy grid.

Biopsy Grid Edit Set the code of the point on the horizontal axis and the vertical axis of the biopsy grid.

NOTE:The code can be uppercase letters, lowercase letters and numbers. And the numbers include decimals.

Page 49: About This Manual Statement - Creche Innovations

4 Customizing Your System

Basic User Manual 41

4.2 Exam Preset Settings

SystemSettings

Load Defaults

Available Items

Selected Items

Delete

Probe Selection L741

C-Vascular Thyroid Breast Superficial Testicular Arterial

MSKL-NerveU-NerveVenous

C-Vascular Thyroid Breast Superficial Testicular Arterial

MSKL-NerveU-NerveVenous

Exam Preset

Comment

Bodymark

Measure

Report

Peripheral

General

DICOM

Help

Load Default

About

Apply

Exit

Exam Preset

Figure 4-6 Exam Preset Settings Menu

Select one probe and all the preset exam type icons are displayed in the Available Items list. You can modify the layout of the Application Mode screen by moving the icon left or right, up or down or deleting the desired icon in the Selected Items list and restore the factory defaults.

● Click the drop-down list beside Probe Selection to select the desired probe model.

● Select an exam type icon in the Available Items list and click to move this icon to the Selected Items list.

● Press and hold the confirm key, move the trackball to select one or more exam type icons and click to move all the selected icons to the Selected Items list.

● Select an exam type icon in the Selected Items list and click , , or to move this icon.

● Select an exam type icon in the Selected Items list and click Delete to delete this icon from the list.

● Click Apply to save the settings and the set icons are displayed on Figure 6-1.

Page 50: About This Manual Statement - Creche Innovations

4 Customizing Your System

42 Basic User Manual

4.3 Annotation Settings

You can make annotation settings on the Tools and List tabs

4.3.1 Tools Settings

Exam Preset

Comment

Bodymark

Measure

Report

Peripheral

General

DICOM

Help

Load Default

About

Apply

Exit Load Defaults

SystemSettings

Tools List

AnnotationSelect annotation Language English

Font size Medium

Clear annotation while unfreezing image On

ArrowArrow size Medium

On

Set home

Clear annotation while unfreezing image

Figure 4-7 Annotation Settings Menu - Tools Tab

■  Text Annotation Settings 

Item Description

Select annotation

language

Set the language of the text annotations.

Font size Set the font size of the typed words.

Clear annotation while unfreezing image

Enable or disable the auto-clear text annotation feature after unfreezing an image.

● Set it to ON, all annotations are cleared after you press the key in the text annotation editing mode.

● Set it to OFF, all annotations are not cleared after you press the key in the text annotation editing mode.

Page 51: About This Manual Statement - Creche Innovations

4 Customizing Your System

Basic User Manual 43

■  Arrow Annotation Settings

Item Description

Arrows size Set the size of the arrow.

Clear arrow while unfreezing image

Enable or disable the auto-clear arrow feature after unfreezing an image.

● Set it to ON, all arrows are cleared after you press the key in the arrow annotation editing mode.

● Set it to OFF, all arrows are not cleared after you press the key in the arrow annotation mode.

■  Set Home Settings

Item Description

Middle, Bottom, Left, Top, Right

Set the initial position of annotations and arrow annotations.

4.3.2 List Settings

Load Defaults

Tools List

Application

Annotation selected

ABD

Library

LiverCaudateR-LobeL-LobeHepatic VM-Hepatic VR-Hepatic VL-Hepatic VPortal VHepatic AGBBile DuctPanPan Duct

ABD

Page1 Page2

Shadow>

>>

<

<<

Add Delete

Add Delete

Liver CaudateR-Lobe L-LobeHepati... V M-Hep...R-Hep... V L-Hep...Portal V Hepati...GB Bile DuctPan Pan Duct

Exam Preset

Comment

Bodymark

Measure

Report

Peripheral

General

DICOM

Help

Comment

Load Default

About

Apply

Exit

SystemSettings

Figure 4-8 Comment - Settings tab

Page 52: About This Manual Statement - Creche Innovations

4 Customizing Your System

44 Basic User Manual

Perform the following steps.

1. Select an exam type from the drop-down list beside Application.

2. Select a text annotation library from the drop-down list beside Library.

3. Add the desired text annotations in the selected library to the Annotation Selected list.

− Select a text annotation and click > to add it to the Annotation Selected list. − Click >> to add all text annotations in the selected library to the Annotation Selected list.

− Select a text annotation in the Annotation Selected list and click < to remove it from the Annotation Selected list.

− Click << to remove all text annotations from the Annotation Selected list.4. Select a text annotation in the Annotation Selected list and click , , or to

arrange its display.

4.4 Body Mark Settings

List

>

>>

<<

<

Exam Preset

Comment

Bodymark

Report

Peripheral

General

DICOM

Help

Measure

Load Default

About

Apply

Exit

Bodymark

System Setting

Application ABD

AvailableApplication ABD

Selected

Load Default

Figure 4-9 Body Mark Settings Screen

1. Select an exam type from the drop-down list beside Application.

2. Select a body mark library from the drop-down list beside Application of Available.

3. Add the desired body marks in the body mark library to the Selected list.

− Select a body mark and then click > to add it to the Selected list.

Page 53: About This Manual Statement - Creche Innovations

4 Customizing Your System

Basic User Manual 45

− Click >> to add all the body marks in the selected body mark library to the Selected list.

− Select a body mark in the Selected list and click < to remove it from the Selected list.

− Click << to remove all the body marks from the Selected list.4. Select a body mark in the Selected list and then click , , or to arrange its

display.

4.5 Measurement Settings

You can adjust measurement settings on the General, Application and List tabs.

4.5.1 General Measurement Settings

Load Defaults

2D

M+D

MediumCross Cursor Size

On

OnMeasure Line Size

OnDist. Dash Line Disp.

OnVel. Cross Line Disp.

OnEllip. Cross Line Disp.

Volume Flow Method TAmean

Volume Flow compensation with TAmax 0.50

MediumResult Font Size

WhiteResult Font Color

BSA Eastern

Keep Result Window On

Exam Preset

Comment

Bodymark

Measure

Report

Peripheral

General

DICOM

Help

Measure

Load Default

About

Apply

Exit

System Setting

General Application List

General Result Position

Left Top

Left TopLine ID Disp.

Figure 4-10 General Measurement Settings Screen

Item Description

Cross Cursor Size Set the size of the cross cursor.

Line ID Disp. Enable or disable the display of line number when performing a measurement.

Page 54: About This Manual Statement - Creche Innovations

4 Customizing Your System

46 Basic User Manual

Item Description

Measure Line Size Set the thickness of the measurement line.

Dist. Dash Line Disp. Enable or disable the display of a dash line between two points when performing a distance measurement.

Vel. Cross Line Disp. Enable or disable the display of a reticle between two points when performing a velocity measurement.

Ellip. Cross Line Disp. Enable or disable the display of dash lines for long and short axes when performing an ellipse measurement.

Volume Flow Method Set the measurement method of volume flow.

Vo l u m e F l o w w i t h Compensation TAmax

Set the coefficient of volume flow with compensation TAmax.

Result Font Size Set the font size of the result box.

Result Font Color Set the font color of the result box.

BSA In accordance with the setting of this item, the system calculates BSA value automatically after you enter the height and weight of the patient on the Patient Information screen.

Keep Result Window while unfreezing image

Enable or disable the display of the current result box when unfreezing the image.

■  Result Position

Item Description

2D Set the position of the result box in 2D, M mode and Doppler mode.M+D

Page 55: About This Manual Statement - Creche Innovations

4 Customizing Your System

Basic User Manual 47

4.5.2 Application Settings

AC/BPD(Hadlock)HadlockWilliamsg

BPD,HC,AC,FL

NO

YES

AUACUA/AUAPS

ED

RI

PI

S/D

TAmax

TAmean

VTI

HR

Auto/Man Trace

Num 1

Num2

Num3

Num4

Num5

Num 6

Num7

Num8

Num9

Num0

Exam Preset

Comment

Bodymark

Measure

Report

Peripheral

General

DICOM

Help

Measure

Load Default

About

Apply

Exit

General ListApplication

Application

OB

Shortcut Key Measurement Setting

Add 1 week to EDD

Show EDD on screenEquation

GA&GrowthNew Table

Fetal WeightEstimation

Age by EFW

EFW GP/SD

Unit

CUA

CUA

Load Default

System Setting

Figure 4-11 Application Settings Screen

■  Auto/Man Trace

After selecting an exam type from the drop-down list below the Application tab, set the measurement items of Auto/Man Trace in the spectral Doppler mode.

■  Shortcut Key

Select OB, GYN or Cardiac from the drop-down list beside Application, and then select a measurement item from the drop-down list beside Num 0 to Num 9. After adjusting these settings, you can perform the Obstetrics, Gynecology or Cardiology measurement by using the defined shortcut key.

■  Small Parts Measurement Settings

Select SMP from the drop-down list beside Application and set the calculation coefficient of the thyroid volume formula.

■  Obstetrics Measurement Settings

Set the formula for obstetrics measurement.

Page 56: About This Manual Statement - Creche Innovations

4 Customizing Your System

48 Basic User Manual

Item Description

CUA/AUA Set to display CUA or AUA on the measurement report.

CUA stands for Composite Ultrasound Age, and AUA stands for Average Ultrasound Age.

Add 1 week to EDD Set to add one week to EDD.

Show EDD on screen Set to display EDD in the measured result box.

Estimation Set the formula to estimate EFW.

If it is set to None, the system will not estimate fetal weight and no corresponding value displays on the measurement report.

Age by EFW Set the formula to estimate GA by EFW.

If it is set to None, the system will not estimate GA by EFW and no corresponding values will be displayed on the measurement report.

EFW GP/SD Set the formula of the fetal growth curve.

If it is set to None, no values of the fetal growth curve are displayed on the measurement report.

Unit Set the weight unit.

CUA Set the CUA formula.

If it is set to None, the system will not estimate CUA and no corresponding values are displayed on the measurement report.

You can customize the formula for gestational age and growth curve.

Perform the following steps as follows:

1. Click New Table to pop up the New Table dialog box.

2. Select New GA Table or New Growth Table and click OK. The screen shown in Figure 4-12 or Figure 4-13 pops up.

Page 57: About This Manual Statement - Creche Innovations

4 Customizing Your System

Basic User Manual 49

GA Table

Measurement

Meas[mm] -2SD[w+d] Mean[w+d] +2SD[w+d]

Unit

Author Deviation -2SD/+2SD

mmMeas

12345678910111213141516171819

-2SD Mean +2SDw+d w+d w+d

ExitSave&Exit

Figure 4-12 GA Table

Growth Table

Measurement

Age[w+d] -2SD[mm] Mean[mm] +2SD[mm]

Unit

Author Deviation -2SD/+2SD

w+dAge

12345678910111213141516171819

-2SD Mean +2SDmm mm mm

ExitSave&Exit

Figure 4-13 Growth Table

Page 58: About This Manual Statement - Creche Innovations

4 Customizing Your System

50 Basic User Manual

3. Select or input the Measurement, Author, Deviation and the corresponding Unit.

4. Enter the gestational weeks and the values of measurement items in the table.

5. Click Save&Exit to save the customized formula and exit.

4.5.3 List Settings

B Color M Doppler

Default

Exam Preset

Comment

Bodymark

Measure

Report

Peripheral

General

DICOM

Help

Measure

Load Default

About

Apply

Exit

General Application List

Application Abdomen

Caliper Calc

List

Category Collection Measurement

Liver

Port.V. HeightGallbladder WidthPancreasSpleenKidneyRenal AAortaBladder

Length

Measurement

Add Delete

Load Default

System Setting

Figure 4-14 List Settings Screen

You can add, delete or reorder the measurement collections and items in each imaging mode of the selected application.

■  To Add a Collection or Measurement

Perform the following steps as follows:

1. Select an exam type from the drop-down list beside Application.

2. Select Caliper or Calc.

3. Select an imaging mode in the List frame and click the Collection or Measurement.

4. Click Add to add the desired collection or measurement on the pop-up screen.

5. Click Close to complete.

■  To Delete a Collection or Measurement

Perform the following steps as follows:

Page 59: About This Manual Statement - Creche Innovations

4 Customizing Your System

Basic User Manual 51

1. Select an exam type from the drop-down list beside Application.

2. Select Caliper or Calc.

3. Select an imaging mode in the List frame and select the collection item or measurement item that you wish to delete.

4. Click Delete.

4.6 Report Settings

Exam Preset

Comment

Bodymark

Measure

Peripheral

General

DICOM

Help

Load Default

About

Apply

Exit

SystemSettings

Report

Load DefaultsPreview

bmp: 170×60

Patient Information

0/0

Title 1

Title 2

Title 3

Content

Import/Export

Title/Font/Color

Display Items For Report

24 Title 24

Sub-Title 14

Background Color

Text Color

20

20

12

Patient InformationExam InformationExam Information

MeasurementsMeasurementsImagesImagesGraphsGraphs

ConclusionComment

Logo

Figure 4-15 Report Settings Menu

Item Description

Import/Export Connect the USB drive containing the report logo (170×60 pixels, bmp format) to the system. Import/Export is highlighted after the USB drive is successfully detected by the system.

Click Import/Export, and then click the desired logo in the pop-up dialog box to add the logo.

If there is more than one logo, you can click icon or icon to select the desired logo.

Page 60: About This Manual Statement - Creche Innovations

4 Customizing Your System

52 Basic User Manual

Item Description

Title 1/2/3 Input the title name in the textbox and then set the font size using the drop-down list.

Context Set the text font size.

Title Set the font size of the headline.

Subtitle Set the font size of the subtitle.

Background Color Set the background color of the measurement report.

Content Set the font size of report content.

Text Color Set the text color.

Display Items for Report

Select items to be displayed on the measurement report. Patient and exam information is displayed on the report by default. Other information can also be displayed on the report after you tick Measurement, Image, Graphs or Comments.

After settings, you can click Preview to preview the report.

Page 61: About This Manual Statement - Creche Innovations

4 Customizing Your System

Basic User Manual 53

4.7 Peripheral Devices Settings

4.7.1 Basic Settings

Exam Preset

Comment

Bodymark

Measure

General

DICOM

Help

Load Default

About

Apply

Exit

SystemSettings

Report

Load Defaults

Peripheral

Video Output

Basic Network

CVBS/S-VIDEO

HDMI

Foot Switch

Printer

Default Printer

Printer IP AddressPrinter Port Number

Windows Printer192.168.1.1016050

CLOSE

Area Picture Area

CLOSE

Left Key Save Image

Right key Freeze/Unfreeze

Figure 4-16 Peripheral Devices Settings - Basic Tab

Item Description

Area Set the video output area.

CVBS/S-VIDEO Set the video type.

HDMI Set the definition of HDMI output.

Default Printer Set the type of the default printer.

Printer IP Address Set the IP address of the computer connecting a printer.

Printer Port Number Set the port number of the printer.

Left Key/Right Key Set the function of the foot switch.

Page 62: About This Manual Statement - Creche Innovations

4 Customizing Your System

54 Basic User Manual

4.7.2 Network Settings

Exam Preset

Comment

Bodymark

Measure

General

DICOM

Help

Load Default

About

Apply

Exit

SystemSettings

Report

Load Defaults

Peripheral

Basic Network

DHCP

Local Network

IP Address:Mr.Wu Unconnected

Connect

Static IP

Netmask:

Enable

Default Gateway:

Disconnect

Refresh Advance

Mac Address:

Ping IP Address:

Ping

Wireless NetworkEnable

Name State Level

192.168.8.149

255.255.255.0

192.168.8.1

Figure 4-17 Peripheral Device Settings - Network Tab

■  Local Network

Item Description

Local Network Enable or disable the local network from the drop-down list.

Address Mode Select an IP address mode.

IP Address Set the IP address of the system.

Netmask Set the netmask address of the system.

Default Gateway Set the gateway address of the system.

Mac Address View the MAC address of the system.

Ping IP Addr. Type an IP address and click Ping to test the connection.

Page 63: About This Manual Statement - Creche Innovations

4 Customizing Your System

Basic User Manual 55

■  Wireless Network

Item Description

Wireless Network Enable or disable the wireless network.

Name Displays the name of the wireless network.

State Displays the connection status of the wireless network.

Level Displays the signal strength of the wireless network.

Advance Click Advance to view the information of your current network, and make settings of your local network.

Connect the wireless network as follows.

1. Click Refresh to display all wireless networks on the menu.

2. Select the desired wireless network and click Connect.

3. Input the password in the pop-up dialo box if needed and click OK.

4.8 DICOM Settings

4.8.1 DICOM Service Settings

You can add, edit or delete DICOM servers, and test connectivity on the DICOM Service tab.

● Click Add, and select a DICOM server type and input server information. When server is added to the Service List, Service Type, Service Name, AE Tiltle, IP Address will be displayed.

● Select Service List, and click Edit to edit server information in the pop-up dialog box.

● Select Service List, and click Delete to delete the server.

● Select Service List, and click Ping to test if the network is connect well. Click Verify to test the connectivity between the system and the server.

Page 64: About This Manual Statement - Creche Innovations

4 Customizing Your System

56 Basic User Manual

Exam Preset

Comment

Bodymark

Measure

General

DICOM

Help

Load Default

About

Apply

Exit

SystemSettings

Report

Peripheral

Service List

DICOM Service Local Setting

Add Edit Delete Ping Verify

Service Type

StoreSCP DicomStore AE 192.168.254.104 104

Service Name AE Title IP Address Port

Figure 4-18 DICOM Service Settings Screen

■  Storage Server Settings

Add Dicom Service

Service Type Storage

Service Name

AE Title

IP Address

Port Number

Storage Commitment Server

Ping

Verify

ResetCancelSave

Item Description

Service Name Set the server name of the DICOM storage server.

AE Title Set the Application Entity (AE) title of the DICOM storage server.

Page 65: About This Manual Statement - Creche Innovations

4 Customizing Your System

Basic User Manual 57

Item Description

IP Address Set the IP address of the DICOM storage server.

Click Ping to test the connection.

Port Number Set the port number of the DICOM storage server.

Storage Commitment Server

Set the storage commitment server of the DICOM storage server.

Click Verify to verify the connection between the system and the DICOM storage server after you input the settings for Service Name, AE Title, IP Address and Port Number.

■  Structured Report Settings

Add Dicom Service

Service Type Structured Report

Service Name

AE Title

IP Address

Port Number

Storage Commitment Server

Ping

Verify

ResetCancelSave

Item Description

Service Name Set the server name of the DICOM report server.

AE Title Set the Application Entity (AE) title of the DICOM report server.

IP Address Set the IP address of the DICOM report server.

Click Ping to test the connection.

Port Number Set the port number of the DICOM report server.

Storage Commitment Server

Set the storage commitment server of the DICOM report server.

Click Verify to verify the connection between the system and the DICOM storage server after you input the settings for Service Name, AE Title, IP Address and Port Number.

Page 66: About This Manual Statement - Creche Innovations

4 Customizing Your System

58 Basic User Manual

■  Storage Commitment Server Settings

Add Dicom Service

Service Type Storage Commitment

Service Name

AE Title

IP Address

Port Number

Ping

Verify

ResetCancelSave

Item Description

Service Name Set the server name of the DICOM storage commitment server.

AE Title Set the Application Entity (AE) title of the DICOM storage commitment server.

IP Address Set the IP address of the DICOM storage commitment server.

Click Ping to test the connection.

Port Number Set the port number of the DICOM storage commitment server.

Click Verify to verify the connection between the system and the DICOM storage server after you input the settings for Service Name, AE Title, IP Address and Port Number.

Page 67: About This Manual Statement - Creche Innovations

4 Customizing Your System

Basic User Manual 59

■  Worklist Settings

Study Type

Maximum Results

Query Date

Add Dicom Service

Service Type Worklist

Service Name

AE Title

IP Address

Port Number

Ping

Verify

ResetCancelSave

Item Description

Service Name Set the server name of the DICOM worklist server.

AE Title Set the Application Entity (AE) title of the DICOM worklist server.

IP Address Set the IP address of the DICOM worklist server.

Click Ping to test the connection.

Port Number Set the port number of the DICOM worklist server.

Study Type Set the automatic study type of the DICOM worklist server.

Maximum Results Set the maximum number of patient records that can be sent to the system.

Query Date Set the time range automatic query of the DICOM worklist server.

Click Verify to verify the connection between the system and the DICOM storage server after you input the settings for Service Name, AE Title, IP Address and Port Number.

Page 68: About This Manual Statement - Creche Innovations

4 Customizing Your System

60 Basic User Manual

■  MPPS Settings

Storage Server

SR Server

Add Dicom Service

Service Type MPPS

Service Name

AE Title

IP Address

Port Number

Ping

Verify

ResetCancelSave

Item Description

Service Name Set the server name of the MPPS server.

AE Title Set the Application Entity (AE) title of the MPPS server.

IP Address Set the IP address of the MPPS server.

Click Ping to test the connection.

Port Number Set the port number of the MPPS server.

Storage Server Set the storage server of the DICOM MPPS server.

Structured Report Set the structured report of the DICOM MPPS server.

Click Verify to verify the connection between the system and the DICOM storage server after you input the settings for Service Name, AE Title, IP Address and Port Number.

Page 69: About This Manual Statement - Creche Innovations

4 Customizing Your System

Basic User Manual 61

■  Query Retrieve Settings

Add Dicom Service

Service Type Query Retrieve

Service Name

AE Title

IP Address

Port Number

Maximum Results

Ping

Verify

ResetCancelSave

Item Description

Service Name Set the server name of target ultrasound system that retrieve patient information of the DICOM query retrieve server.

AE Title Input the Application Entity (AE) title of target ultrasound system that retrieve patient information of the DICOM query retrieve server.

IP Address Input the IP address of target ultrasound system that retrieve patient information of the DICOM query retrieve server.

Click Ping to test the connection.

Port Number Input the port number of target ultrasound system that retrieve patient information of the DICOM query retrieve server.

Maximum Results Set the maximum number of patient records that can be sent to the system.

Click Verify to verify the connection between the system and the DICOM storage server after you input the settings for Service Name, AE Title, IP Address and Port Number.

Page 70: About This Manual Statement - Creche Innovations

4 Customizing Your System

62 Basic User Manual

■  Print Settings

Service Type Print

Service Name

AE Title

IP Address

Port Number

Ping

Verify

ResetCancelSave

Format 1x1

Mid

Paper

Portrait

A4

Magazine

Cubic

1

1

Yes

White

White

Grey

20

320

Priority

Medium

Orientation

Film Size

Film Destination

Magnification

Copies

Smoothing Type

Trim

Border

Empty Image

Color

Min Density

Max Density

Configure Information

Film Session Label

Print Advance Config

Add Dicom Service

Item Description

Service Name Set the name of the DICOM printing server.

AE Title Input the Application Entity (AE) title of the DICOM printing server.

Port Number Input the port number of the DICOM printing server.

IP Address Input the IP address of the DICOM printing server.

Click Ping to test the connection.

Format Set the printing format.

Trim Set to print or not to print a crop box around each image.

Priority Set the printing priority.

Border Set the color of the border to fill in the gap between the images.

Medium Select the print medium.

Empty Image Set the color of the empty images.

Orientation Set the print orientation.

Page 71: About This Manual Statement - Creche Innovations

4 Customizing Your System

Basic User Manual 63

Item Description

Color Set the color of the image.

Film Size Set the film size.

Min. Density Set the minimum density level of the film.

Film Destination Set the film destination.

● Set it to MAGAZINE, the image will be stored in a film magazine.

● Set it to PROCESSOR, the image will be processed in a film processor.

Max. Density Set the maximum density level of the film.

Magnification Set the method used for magnifying images during the print.

Configure Information Make special image quality settings.

Copies Set the number of copies to print.

Film Session Label Enter a name to be applied on a group of the film labels.

Smoothing Type Set the value of magnification interpolation for the printer.

Click Verify to verify the connection between the system and the DICOM storage server after you input the settings for Service Name, AE Title, IP Address and Port Number.

Page 72: About This Manual Statement - Creche Innovations

4 Customizing Your System

64 Basic User Manual

4.8.2 DICOM Local Settings

Exam Preset

Comment

Bodymark

Measure

General

DICOM

Help

Load Default

About

Apply

Exit

SystemSettings

Report

Peripheral

Load Defaults

Local Device Storage Setting

Station Name

AE Title

Port Number

Timeout(sec)

2D Compression JPEG

2D JPEG Quality Lossless

Cine Compression JPEG

Cine JPEG Quality Lossless

Send at end of exam On

DICOM Service Local Setting

Figure 4-19 DICOM Local Settings Screen

■  Local Device Settings

Item Description

Station Name Input the name of the system.

AE Title Input the Application Entity (AE) title of the system.

Port Number Input the port number of the system.

Connect Timeout(sec) Set the time limit for the network connection timeout.

Page 73: About This Manual Statement - Creche Innovations

4 Customizing Your System

Basic User Manual 65

■  Storage Settings

Item Description

2D Compression Set the compression format of the image.

2D JPEG Quality Set the compression quality of the image.

Cine Compression Set the compression format of the cine.

Cine JPEG Quality Set the compression quality of the cine.

Send at end of exam Tick this item and the system sends all saved images to the DICOM storage server after the exam is complete.

4.9 Help Settings

You can read user manual in electronic format on the Help screen.

4.10 Defining System Defaults

You can define the system defaults on the Loading Defaults menu.

Exam Preset

Comment

Bodymark

Measure

General

DICOM

Help

Load Default

About

Apply

Exit

SystemSettings

Report

Peripheral

NewLoad Import/Export

default

Figure 4-20 Loading Defaults Menu

4.10.1 Loading System Defaults

1. Click Load, select the desired default system settings and then a dialog box pops up.

Page 74: About This Manual Statement - Creche Innovations

4 Customizing Your System

66 Basic User Manual

2. Click Yes to load the system default.

Click Cancel to cancel loading default settings, or click Delete to delete the selected default settings.

4.10.2 Creating System Defaults

Click New, and the name of the new default settings will be shown on the Load tab.

If the name of the new default settings already exists, you can click Replace to replace the existing default settings.

4.10.3 Exporting or Importing System Defaults

Click Export/Import to enter the Export/Import menu.

System Setting

Peripheral

General

Comment

Measure

Bodymark

Report

Peripheral

DICOM

Load Default

About

Exit

Save&Exit

New Export/ImportLoad

Make sure USB drive in the USB slot

Copy user setting to USB

Copy user preset to USB

Load USB user setting to system

Load USB user preset to system

Export Log

Caution: Copy USB to hard drive will replace all user settingin the system including patient database, Please use it wisely

Figure 4-21 Exporting or Importing System Defaults

Ensure the USB drive is connected to the system before exporting or importing the system defaults.

● Click Copy user setting to USB to back up the system defaults to the USB drive.

● Click Copy user preset to USB to back up the customized system defaults to the USB drive.

● Click Load USB user setting to system to copy the system settings to the system.

● Click Load USB user preset to system to copy the customized system to the system.

● Click Export Log to export the log to the USB drive.

Page 75: About This Manual Statement - Creche Innovations

4 Customizing Your System

Basic User Manual 67

4.11 Viewing System Information

You can view the current hardware version, the software version and the control number on the System tab. The control number is a unique number for the system.

Page 76: About This Manual Statement - Creche Innovations

T h i s p a g e i s i n t e n t i o n a l l y l e f t b l a n k .

Page 77: About This Manual Statement - Creche Innovations

69

5    Preparing for an Exam

You can start an exam without entering any patient information. To avoid patient identification errors, you should always verify the identification information with the patient.

Page 78: About This Manual Statement - Creche Innovations

5 Preparing for an Exam

70 Basic User Manual

5.1 Acquiring Patient Information

You can acquire the patient information in the following ways.

● Create new patient information.

● Retrieve archived patient information.

● Receive patient information using the DICOM worklist.

● Retrieve patient information from other ultrasound systems.

5.1.1 Beginning a New Patient

Press the Patient key on the control panel to display the New Patient screen in Figure 5-1.

New Patient

Base Information

Exam Information

Patient ID

Last Name M.I

First Name

DOB Age D01/01/1970

Sex Comments

Accession#

Description

Chief Compliant

Past History

Referring.M.D

Performing.M.D

Sonographer

Comments

OB

Weight kg lb

Height

Eastern

cm

BSA(m^2)

in

Auto

Patient List WorkList

BP(mmHg) (KPa)/ /Y M

Unknown

OK Cancel

GYN Cardiac Vascular Urology SMP PED MSKABD Nerve Ortho Others

Suspend Exam Clear Data

Figure 5-1 New Patient Screen

NOTE:

• You can move the cursor by using the trackball and then press the confirm key to select the desired item.

• You can enter the information by using the keyboard.

Perform the following steps to begin a new patient.

1. Enter the relevant patient information

Page 79: About This Manual Statement - Creche Innovations

5 Preparing for an Exam

Basic User Manual 71

Patient ID Enter the patient ID. The system will generate the patient ID automatically according to the current system time if this item is left blank.

NOTE:The patient ID is an important identification. Once it is saved, you cannot modify it.

Name Enter first name, middle name and last name of the patient.

DOB Enter the date of birth for the current patient. The date format depends on the settings on the System Settings menu > General menu > General tab.

Age The patient’s age will be automatically calculated if you enter the information in the DOB textbox.

Sex Select the gender of the current patient from the drop-down list.

Accession# Enter the exam ID for the current patient. Only numbers are allowed to be entered.

Weight and Height Enter the weight and height for the current patient.

BSA The system will automatically calculate the body surface area after you enter the weight and height. You can select the calculation formula from the corresponding drop-down list.

BP Enter the blood pressure for the current patient.

Comments Make comments for the current patient.

2. Select the exam type

Exam type Select an exam type for the current patient, including Abdomen, Obstetrics, Gynecology, Cardiology, Vascular, Urology, Small Parts, Pediatrics, Musculoskeletal, Neurology, Orthopedics and others.

Description Enter the information related to the exam type.

Primary Indications Enter the related information.

Secondary Indications Enter the related information.

Page 80: About This Manual Statement - Creche Innovations

5 Preparing for an Exam

72 Basic User Manual

NOTE:• You must enter the height and weight for the current patient when you

select Cardiology as the exam type. BSA will be automatically calculated in accordance with the BSA set on the Measure menu.

• You must enter LMP or EDD for the current patient when you select Obstetrics as the exam type. AUA will be automatically calculated.

3. Enter the related operating information

R e f e r r i n g . M . D /P e r f o r m i n g . M . D /Sonographer

Enter the name.

Comment Enter the notice or necessary information.

4. Click OK to save the modifications.

− Click Clear Data to delete the patient information. − Click Cancel to abort editing the patient information and exit the New Patient screen.

5.1.2 Retrieving Archived Information

You can retrieve the archived information by choosing the Patient key > Patient List.

Patient Exam List

Patient ID Last Name First Name Age Sex

Date --11/9/2017 11/9/2017

Exit

Exam Type

ABD 2015/12/12-01:13:24 0.73M Suspend

Exam Date/Time Image Size

Reset

Resume Exam New Exam

Store State Exam StatusPatient Review Exam Review 20150505_160337_101232

Close Exam View Image

Description Sonographer

Delete Exam DICOM SendDICOM Print

Import Screen

Export Screen

Current Exam

New Patient

PPS Screen

DICOM Queue

DICOM Q/R

Free Space:

Figure 5-2 Exam View Screen

Perform the following steps to retrieve information.

1. Search for the archived information

Enter the search requirements, such as Patient ID, First/Last Name, Sex, Date or Age, and the desired information is displayed in the list.

Page 81: About This Manual Statement - Creche Innovations

5 Preparing for an Exam

Basic User Manual 73

View New Exam Delete Patient

Patient ReviewPatient ID

20150505 Mary Unknown 2015/05/05-16:04:03 40.82M

Patient Name Birth Date Sex Exam Time Image Size Status

Patient Exam List

Patient ID Last Name First Name Age Sex

Date --11/9/2017 11/9/2017

Exit

Reset

Import Screen

Export Screen

Current Exam

New Patient

PPS Screen

DICOM Queue

DICOM Q/R

Free Space:

Figure 5-3 Patient View Screen

2. Select the desired information

Move the cursor to the desired information, and press the confirm key on the control panel to select it.

3. Exam the desired patient

Click New Exam to start a new exam.

5.1.3 Using DICOM Worklist

You can acquire the patient information by using the DICOM worklist if the system is configured with the DICOM module. For details, refer to Section 9.4 DICOM Worklist.

5.1.4 Using Query/Retrieve List

You can acquire the patient information from other ultrasound systems by using the Query/Retrieve List and copy the patient information to the system if the system is configured with the DICOM module. For details, refer to Section 9.5 Query/Retrieve List.

5.2 Pausing/Resuming/Completing an Exam

5.2.1 To Pause an Exam

Press the Patient key on the control panel to enter the New Patient screen, and then click Suspend Exam to pause the exam.

5.2.2 To Resume an Exam

1. Press the Patient key on the control panel to enter the New Patient screen, and then click Patient List > Patient View to enter the Patient View screen.

Page 82: About This Manual Statement - Creche Innovations

5 Preparing for an Exam

74 Basic User Manual

2. Select the desired patient information, and then click View to enter the Exam View screen.

3. Select the desired exam, and then click Resume Exam to resume the exam.

5.2.3 To Complete an Exam

Press the End Exam key on the control panel to end the current exam.

Click Confirm on the pop-up dialog box to confirm to end the current exam.

Page 83: About This Manual Statement - Creche Innovations

75

6    Acquiring Images

You can acquire images by optimizing the relevant parameters for clinical diagnosis.

Page 84: About This Manual Statement - Creche Innovations

6 Acquiring Images

76 Basic User Manual

6.1 Selecting a Probe and an Exam Type

Once you power on the system, the system enters the real time B mode by default. You can press the Probe key to enter the Application Mode screen (as shown in Figure 6-1) and select the desired application mode.

XXX

C-Vascular Thyroid Breast Superficial Testicular Arterial

MSKL-NerveU-NerveVenous

Figure 6-1 Application Mode Screen

NOTE:

Ensure the probe model and icon displayed on the application mode screen are consistent with the connected probe. If a problem is found, check that the probe is connected to the system firmly. If the problem still exists, please stop using the system immediately and contact the manufacturer.

You can make modifications in an exam type and save them as an application preset for future use. Moreover, the layout of the application mode screen can be modified and factory defaults can be restored.

6.1.1 To Customize a Preset

1. Select the desired probe and exam type.

2. Select an imaging mode and optimize the image.

NOTE:Parameter optimizing is only available for the current imaging mode.

3. Press the S key on the key panel.

4. Click Yes in the pop-up dialogue box to enter the User Pre-set Menu screen, as shown in Figure 6-2.

Page 85: About This Manual Statement - Creche Innovations

6 Acquiring Images

Basic User Manual 77

Save Exit

Type

Name

Abdomen

Part C-Vascular

User Pre-Set Menu

Figure 6-2 User Pre-set Menu Screen

5. Enter the name of the application preset in the Name textbox.

6. Select the department and exam type from the Type and Part lists.

7. Click Save to create the customized application preset.

If the name of the application preset exists, you can click Yes in the pop-up dialogue box to replace it.

6.1.2 To Arrange the Presets Display

Press the S key on the Application Mode screen to enter the User Preset Menu screen, as shown in Figure 6-3.

Load Default

Delete

Down

Up

Preset Exam:

C-VascularThyroidBreastSuperficialTesticular

ArterialVenousU-NerveL-NerveMSKa

User Preset Menu

Exit

Figure 6-3 Preset Display Screen

● Select one desired application preset and click Up or Down to arrange the preset on the application mode screen.

● Select one desired application and click Delete > Yes to delete the application preset.

● Click Load Default > Yes in the pop-up dialogue box to restore factory defaults.

Page 86: About This Manual Statement - Creche Innovations

6 Acquiring Images

78 Basic User Manual

6.2 Acquiring B-Mode Images

B-mode imaging is intended to provide information of anatomical structure of soft tissue.

6.2.1 Entering B Mode

The system enters B mode by default after you select a probe model and an exam type.

You can press the B key on the control panel to enter B mode from other imaging modes.

The basic screen in the B mode is displayed as follows:

1

2

3

4

NEXT

FR

B

7.5

14.07.5-10.5F

D50GN50DR

75PWR

offµS

s

1/1P

Frequency3.7-4.5

Line DensityMed

Gray Map2

ChromaOff

μScan3

PersistLow

DR140

Power100%

Sector Width100%

Focus Area3

WidescanOff

Compound1

0

5

10

15

Figure 6-4 B-Mode Imaging Screen

For details on operating the basic screen, refer to Section 2.3.7 Basic Screen.

6.2.2 Optimizing B-Mode Images

After entering the B mode, the imaging parameters display at the bottom of the LCD monitor as shown in Figure 6-4.

To optimize the image:

● Press the function key on the control panel to select the corresponding parameter.

● Rotate the function key to adjust the settings of the corresponding parameter.

● Press the NEXT/BACK key corresponding to NEXT to go to the next or previous page.

Page 87: About This Manual Statement - Creche Innovations

6 Acquiring Images

Basic User Manual 79

NOTE:

You can adjust all parameters in the real time B mode, but can only adjust Rotation, Chroma, Gray Map and μScan in the frozen B mode.

■  Gain

The B mode gain (2D gain) determines the amplifying factors for the received echoes and the brightness of the ultrasound image. The echoes are amplified with the same gain value regardless of depth.

You can rotate the Gain knob on the control panel to adjust the value.

■  TGC

TGC (Time Gain Compensation) is used to adjust the gain that allows compensation for attenuation of the echoes over time (depth). It is adjustable during the real time mode regardless of the imaging mode and display format.

TGC balances the image so that the density of echoes is the same throughout the image.

You can move the desired TGC slider to adjust the value.

NOTE:

• Modifications of TGC values cannot be saved if you shift to use another imaging mode.

• The TGC curve is displayed at the right side of the imaging area when you adjust TGC values, and the curve disappears if TGC values are not adjusted for more than 3 seconds.

■  LGC

It is used to adjust the brightness on the left or right part of the image.

To adjust the LGC:

1. Press the function key to select the desired LGC menu item.

2. Rotate the function key to adjust the values.

■  Focus Area

It is used to adjust the depth range of the ultrasound beam and the focal span. Focus optimizes the image by increasing the resolution for a specific area.

To adjust the focal area:

1. Press the function key to select Focus Area.

2. Rotate the function key to adjust the settings.

You can also press the Focus switch to adjust the focus position.

Page 88: About This Manual Statement - Creche Innovations

6 Acquiring Images

80 Basic User Manual

■  Depth

Depth is used to adjust the distance over which the B-Mode image is anatomized.

You can press the Depth switch to adjust the depth range of the 2D image and the size of image.

NOTE:

• The frame rate varies with the depth.

• The range of the scanning depth varies with the probe. D (depth) is displayed at the left side of the screen.

■  Frequency

The probe is capable of receiving a broadband signal with a certain start frequency and a certain bandwidth. A higher frequency brings about higher resolution and lower penetration.

To adjust the frequency:

1. Press the function key to select Frequency.

2. Rotate the function key to adjust the value.

■  Chroma

Chroma is used to colorize the gray scale image to enhance the discrimination capability.

To adjust the chroma:

1. Press the function key to select Chroma.

2. Rotate the function key to choose a color scheme.

■  Persistence

Persistence is used to average consecutive frames to provide a smoother appearance with less noise. Use lower persistence values for fast-moving organs or tissues and higher persistence values for a smoother appearance.

To adjust the persistence:

1. Press the function key to select Persist.

2. Rotate the function key to adjust the settings.

■  Gray Map

Gray map optimizes the brightness of each pixel in accordance with the corresponding echo.

To adjust the gray map:

Page 89: About This Manual Statement - Creche Innovations

6 Acquiring Images

Basic User Manual 81

1. Press the function key to select Gray Map.

2. Rotate the function key to adjust the value.

■  Compound Imaging

Compound imaging is used to acquire a series of overlapping image frames from substantially differing spatial directions and combining these images to reduce speckle and improve contrast resolution.

To use the compound imaging:

1. Press the function key to select Compound.

2. Rotate the function key to enable or disable the feature.

■  Line Density

Line density refers to the amount of ultrasound beam that makes up the image. Increasing the value of line density improves the resolution and decreases frame rate. Therefore, you have to balance the frame rate and the image quality when adjusting the line density.

A higher line density is useful in obtaining a very high resolution, such as the thyroid or testicles. A lower line density is useful when scanning fetal heart beat, adult cardiac applications and in clinical radiology applications.

To adjust the line density:

1. Press the function key to select Line Density.

2. Rotate the function key to adjust the settings.

■  Dynamic Range

Dynamic range increases the adjustable range of contrast by enhancing the intensities of parts in the grayscale. It optimizes the ultrasound image texture.

To adjust the dynamic range:

1. Press the function key to select DR.

2. Rotate the function key to adjust the value.

■  Sector Width/Angle

Sector width (for linear probes) or sector angle (for curved and phased array probes) is used to adjust the frame rate. You can adjust the sector width or angle to get more information without moving the probe.

The region of interest of the object can be adjusted after you adjust the sector width or sector angle.

To adjust the sector width/angle:

Page 90: About This Manual Statement - Creche Innovations

6 Acquiring Images

82 Basic User Manual

1. Press the function key to select Sector Width.

2. Rotate the function key to adjust the width or angle of the interest area.

■  Power

Power is used to select the amount of ultrasound acoustic power produced by the probe in the B mode. The adjustment range of the power is 1%-100%, and ±5% can be adjusted each time.

To adjust the power:

1. Press the function key to select Power.

2. Rotate the function key to adjust the value.

NOTE:

Expose the patient to the lowest practical transmit power level for the shortest possible period of time to achieve a satisfactory diagnosis.

■  μScan

μScan is used to improve the image quality.

To use the μScan:

1. Press the function key to select μScan.

2. Rotate the function key to adjust the settings or disable the feature.

■  Tissue Specific Imaging

Tissue specific imaging (TSI) refers to the speed of ultrasound passing through the tissue. TSI optimizes the image used for measurement and calculations. The greater tissue specific characteristics the faster the ultrasound passes through the tissues.

To adjust the tissue specific imaging:

1. Press the function key to select TSI.

2. Rotate the function key to choose a tissue type.

■  Widescan

Widescan is used to enlarge the imaging area when performing a real time scan by using the linear probes.

To use the widescan:

● Select Widescan on the control panel to enable the feature.

● Or, select Widescan again on the control panel to disable the feature.

Page 91: About This Manual Statement - Creche Innovations

6 Acquiring Images

Basic User Manual 83

■  Steer

Steer can be adjusted to change the direction of the acoustic beam when performing a real time mode by using the linear probes.

To adjust the steer:

1. Press the function key to select Steer.

2. Rotate the function key to adjust the settings.

NOTE:

Only the linear probes are available when adjusting the steer.

■  Image Rotation

You can rotate the image to get more information.

To rotate the image:

1. Press the function key to select Rotation.

2. Rotate the function key to adjust the settings.

6.3 Acquiring M-Mode Images

M mode is generally used with B mode imaging, and is helpful for cardiac applications. In the M mode, you can position the M line in the B mode image on the anatomy of interest, and then learn about the tissue motion along that line in M-mode trace. In the M-mode, y-axis is used to display the position or depth of the tissue, and x-axis is the time scale.

6.3.1 M Mode

The M line can be only positioned 90° within the ultrasound beam. Therefore, the M mode is used to view motion patterns for regular objects.

Perform the following steps to acquire M-mode images.

1. Optimize a B-mode image.

2. Press the M key on the control panel to enter the inactivated B+M mode.

Page 92: About This Manual Statement - Creche Innovations

6 Acquiring Images

84 Basic User Manual

s 0

5

10

15

M Line

Figure 6-5 Inactivated B+M-Mode Imaging Screen

3. Adjust the position of the M line by using the trackball.

4. Press the Update key to activate the M mode.

The B-mode image with a M line is displayed at the upper part of the screen and the M-mode image is displayed at the lower part of the screen after being activated, as shown in Figure 6-6.

0

5

10

s 0

5

10

15

Y axis: depth

M ImageX axis: time

Figure 6-6 M-Mode Imaging Screen

− X-axis is the time scale. − Y-axis is the depth scale.

Page 93: About This Manual Statement - Creche Innovations

6 Acquiring Images

Basic User Manual 85

NOTE:Once the M mode is activated, you can move the trackball to stop the M trace and adjust the M line. The system continues tracing if the trackball is idle for more than 0.5s.

5. Optimize M-mode image. For details, refer to Section 6.3.2 Optimizing M-Mode Images.

6. Press the M key to exit.

6.3.2 Optimizing M-Mode Images

After activating the M trace, the imaging parameters display at the bottom of the LCD monitor.

To optimize the image:

● Press the function key on the control panel to select the corresponding parameter.

● Rotate the function key to adjust the settings of the corresponding parameter.

NOTE:

You can adjust all parameters in the real time M mode, but can only adjust Chroma and GrayMap in the frozen M mode.

■  Gain

M gain controls the overall brightness of the M trace.

You can rotate the Gain knob to adjust the value.

■  Frequency

The probe is capable of receiving a broadband signal with a certain start frequency and a certain bandwidth in the real time B mode. The higher frequency brings about higher resolution and lower penetration.

To adjust the frequency:

1. Press the function key to select Frequency.

2. Rotate the function key to adjust the value.

■  Gray Map

Gray map optimizes the brightness of each pixel in accordance with the corresponding echo.

To adjust the grayscale curve:

1. Press the function key to select Gray Map.

2. Rotate the function key to adjust the value.

Page 94: About This Manual Statement - Creche Innovations

6 Acquiring Images

86 Basic User Manual

■  Sweep Speed

Sweep speed is used to set the sweep speed of the M trace. A faster speed is more suitable to view the motion.

To adjust the sweep speed:

1. Press the function key to select Sweep Speed.

2. Rotate the function key to adjust the value.

■  Chroma

Chroma is used to colorize the gray scale image to enhance the discrimination capability.

To adjust the chroma:

1. Press the function key to select Chroma.

2. Rotate the function key to choose a color scheme.

■  Display Format

Display format is used to view the image better.

To adjust the display format:

1. Press the function key to select Display Form.

2. Rotate the function key to adjust the settings.

■  Persistence

Persistence is used to average consecutive frames to provide a smoother appearance with less noise. Use lower persistence values for fast-moving organs or tissues and higher persistence values for a smoother appearance.

To adjust the persistence:

1. Press the function key to select Persist.

2. Rotate the function key to adjust the settings.

■  Focus Area

By adjusting the focal area of ultrasound beam, increase the resolution of the special area to focus and optimize the image.

To adjust Focus area:

1. Press the function key to select Focus Area.

2. Rotate the function key to adjust the settings.

You can also press the Focus switch to adjust the focus position.

Page 95: About This Manual Statement - Creche Innovations

6 Acquiring Images

Basic User Manual 87

■  Power

Power is used to select the amount of ultrasound acoustic power produced by the probe in the real time M mode.

To adjust the power:

1. Press the function key to select Power.

2. Rotate the function key to adjust the value.

NOTE:

Expose the patient to the lowest practical transmit power level for the shortest possible time to achieve a satisfactory diagnosis.

6.4 Acquiring Spectral Doppler Images (Optional)

Spectral Doppler imaging is intended to provide measurement data concerning the velocity, the direction, and the category of the arterial or vein flow.

6.4.1 PW Mode

Pulsed Wave Doppler (PW) is a Doppler mode that measures velocity in a PW sample volume and displays that information in a spectral trace with audio output. PW includes conventional PW and High Pulse Repetition Frequency (HPRF). PW Doppler can be combined with the B mode for rapidly selecting the anatomical site for PW Doppler examination. The site where PW Doppler data is derived appears graphically on the B-Mode image.

Perform the following steps to acquire PW-mode images.

1. Optimize a B-mode image.

2. Press the PW key on the control panel to enter the inactivated B+PW mode 1.

Page 96: About This Manual Statement - Creche Innovations

6 Acquiring Images

88 Basic User Manual

Line-Pos

SV-Size

s0

5

10

15

Spectral Doppler Line

Sample Volume Gate

Flow Cursor

2D Image

Figure 6-7 Inactivated B+PW Mode 1 Imaging Screen

− The spectral Doppler line and the sample volume gate are used to locate the qualitative analysis on the image.

− The flow cursor needs to be adjusted parallel to the flow when measuring the velocity.

3. Select Line-Pos by pressing the confirm key to adjust the position and angle of the spectral Doppler line.

− Position the sample volume gate on the spectral Doppler line by moving the trackball up or down.

− Adjust the angle of the spectral Doppler line by moving the trackball left or right.4. Select SV-Size by pressing the confirm key and move the trackball to adjust the size

of the sample volume gate.

5. Rotate the Angle knob to adjust the angle of the flow cursor.

6. Press the Update key to activate the PW mode.

The PW spectrum is displayed at the lower part of the screen after being activated, as shown in Figure 6-8.

Page 97: About This Manual Statement - Creche Innovations

6 Acquiring Images

Basic User Manual 89

s

cm/s

50

-50

0

5

10

15

PW spectrum

Y axis: frequency

X axis: time

Figure 6-8 PW-Mode Imaging Screen

− X-axis is the time scale. − Y-axis is Doppler frequency scale, including positive and negative indicators.

Press the Shift and left/right arrow keys to adjust the audio volume.

Or, rotate the function key corresponding to Volume to adjust the audio volume.

NOTE:Once the PW mode is activated, you can move the trackball to stop the Doppler trace and adjust the sample volume gate. The system continues tracing if the trackball is idle for more than 0.5s.

7. Optimize the PW-mode image. For details, refer to Section 6.4.2 Optimizing Spectral Doppler Images.

If needed, press the Update key on the control panel to enter the inactivated B+PW mode 2, the following screen appears.

Page 98: About This Manual Statement - Creche Innovations

6 Acquiring Images

90 Basic User Manual

s

cm/s

50

-50

0

5

10

15

X axis: time

Y axis: frequency

Figure 6-9 Inactivated B+PW Mode 2 Imaging Screen

You can also adjust the position and angle of spectral Doppler line, the size of sample volume gate, and the direction of the flow cursor.

8. Press the PW key to exit.

6.4.2 Optimizing Spectral Doppler Images

After activating the PW mode, the imaging parameters display at the bottom of the LCD monitor.

To optimize the image as follows,

● Press the function key on the control panel to select the corresponding parameter.

● Rotate the function key to adjust the settings of the corresponding parameter.

NOTE:

You can adjust all parameters in the real time PW mode, but can only adjust Auto Trace, Invert and Chroma and Quick Angle in the frozen PW mode.

■  Gain

PW gain is used to adjust the gain of the spectrum map. Increasing the gain will brighten the image allowing you to see more received signals with less noise.

You can rotate the Gain knob to adjust the value.

Page 99: About This Manual Statement - Creche Innovations

6 Acquiring Images

Basic User Manual 91

■  Scale

Scale is used to adjust the velocity scale.

You can press the Scale switch to adjust the value.

NOTE:

The value of wall filter may change with the scale value.

■  Baseline

Baseline represents the position of zero velocity or frequency. The velocity range in one direction can be increased or decreased by adjusting the baseline.

You can press the Baseline switch to adjust the value.

■  Wall Filter

Wall filter is used to filter the low frequency noise from tissues, such as the vascular wall.

To adjust the wall filter:

1. Press the function key to select WF.

2. Rotate the function key to adjust the value.

■  Display Format

Display format is used to view the image better.

To set the display format:

1. Press the function key to select Display Form

2. Rotate the function key to adjust the settings.

■  Chroma

Chroma is used to colorize the gray scale image to enhance the discrimination capability.

To adjust the chroma:

1. Press the function key to select Chroma.

2. Rotate the function key to choose a color scheme.

■  Frequency

The probe is capable of receiving a broadband signal with a certain frequency and bandwidth.

To adjust the frequency:

1. Press the function key to select Frequency.

2. Rotate the function to adjust the value.

Page 100: About This Manual Statement - Creche Innovations

6 Acquiring Images

92 Basic User Manual

■  Sweep Speed

Sweep speed is used to set the sweep speed of the Doppler trace. The refresh speeds of the time scale and the frequency scale vary with the sweep speed.

To adjust the sweep speed:

1. Press the function key to select Sweep Speed.

2. Rotate the function key to adjust the value.

■  Power

Power is used to select the amount of ultrasound acoustic power produced by the probe. The adjustment range of the power is 1%-100%, and ±5% can be adjusted each time.

To adjust the power:

1. Press the function key to select Power.

2. Rotate the function key to adjust the value.

NOTE:

Expose the patient to the lowest practical transmit power level for the shortest possible time to achieve a satisfactory diagnosis.

■  Angle Correction

Angle correction is used to adjust the angle of the flow cursor in the PW mode.

To set the angle correction:

● Rotate the Angle key on the control panel to adjust the settings.

● Rotate the function key corresponding to Quick Angle to adjust the settings.

NOTE:

You only need to set it when performing measurement related to velocity.

■  Invert

Invert is used to view the flow velocity from a different perspective.

To enable or disable the flow invert:

1. Press the function key to select Invert.

2. Rotate the function key to enable or disable the feature

■  Steer

Steer can be adjusted to change the angle of the spectrum Doppler line when performing a real time mode by using the linear probes.

To adjust the steer:

Page 101: About This Manual Statement - Creche Innovations

6 Acquiring Images

Basic User Manual 93

1. Press the function key to select Steer.

2. Rotate the function key to adjust the settings.

NOTE:

Only the linear probes are available when adjusting the steer.

■  Simult

Simult is used to synchronously display two real time scans in the B mode and the PW modes.

To enable or disable the feature:

1. Press the function key to select Simult in the activate PW or inactivated PW 2 mode.

2. Rotate the function key to enable or disable the feature.

NOTE:

Simult is only available in the PW mode.

■  Auto Trace

Auto trace measurement in the spectral Doppler mode is used to measure the velocity, Pressure Gradient (PG) or other indexes for clinical diagnosis purposes while the system automatically traces one or more Doppler waveforms.

To enable or disable auto trace:

1. Press the function key to select Auto Trace.

2. Rotate the function key to enable or disable the feature.

Page 102: About This Manual Statement - Creche Innovations

T h i s p a g e i s i n t e n t i o n a l l y l e f t b l a n k .

Page 103: About This Manual Statement - Creche Innovations

95

7    Working with Images

You can work with the acquired images by using the features provided by the system, such as the split screen display and annotations.

Page 104: About This Manual Statement - Creche Innovations

7 Working with Images

96 Basic User Manual

7.1 Imaging Features

7.1.1 Imaging Reverse

● Press the key on the key panel to reverse the real time scan left or right.

● Press the key on the key panel to reverse the real time scan up or down.

7.1.2 Split Screen Display

You can position two or four images side by side on the screen to compare the images by using the split screen display.

■  Dual-Split Screen Display

In the B mode, press the key on the control panel to activate the dual-split screen display. Press the key again, the image is duplicated into two parts with a frozen image on the left and a real time scan on the right. The real time B-mode is taken as an example in the following figure.

FRB

7.5

14.07.5-10.5F

D50GN50DR75PWR3µS

s s0

5

10

15

0

5

10

15

Figure 7-1 Frozen + Real Time B

● Press the THI key on the control panel to enter the corresponding mode for the real time scan.

● Press the key on the control panel to freeze the real time scan only.

● Press the key to freeze the real time scan and unfreeze the other image. ● Press the B key to exit the dual display.

■  Quad-Split Screen Display

In the B mode, press the key on the control panel to activate the quad-split screen display. The B-mode image is taken as an example in the following figure.

Page 105: About This Manual Statement - Creche Innovations

7 Working with Images

Basic User Manual 97

FRB

7.5

14.07.5-10.5F

D50Gn50DR75PWR

TM 30

3µS

s

0

5

10

15

Figure 7-2 Quad-Split Screen Display

● Press the THI key on the control panel to enter the corresponding mode for the real time scan.

● Press the key on the control panel to freeze the real time scan only.

● Press the key on the control panel to freeze the real time scan and unfreeze the following clockwise image.

● Press the B key to exit the quad-split screen display.

7.1.3 Auto Optimization

Auto optimization optimizes the image quality.

To enable or disable auto optimization,

● Press the Auto key on the control panel to enable this feature.

● Double click the Auto key to disable this feature.

NOTE:

Auto is displayed in the imaging information area of the basic screen when the feature is enabled.

Page 106: About This Manual Statement - Creche Innovations

7 Working with Images

98 Basic User Manual

7.1.4 Harmonic Imaging

Harmonic Imaging (THI) uses the harmonic frequencies generated by tissue. The fundamental transmit frequency results in a harmonic frequency echo. The harmonic frequency received from the tissue is a multiple of the fundamental transmit frequency. The fundamental and any accompanying artifacts are missing from the harmonic frequency that the system receives. The artifact reduction, and the concomitant reduction in haze and clutter, increases contrast resolution and improves border delineation. THI is useful in difficult-to-image patients. Harmonic Imaging contains THI and PHI.

In real time B mode, press the THI key on the key panel to enable the THI mode, and THI or PHI appears on the left side of the screen. Optimize the image the same way you did in the B mode.

Press the THI key again to exit the imaging, and THI or PHI disappears from the screen

NOTE:

• The system automatically optimizes certain parameters (B-mode gain, frequency and acoustic output power) upon enabling THI.

• Compared to the B-mode imaging, THI improves image resolution but decreases the depth. Therefore, you should make an optimal balance when choosing an imaging mode.

• THI is only available with compatible probes.

7.1.5 Panoramic Imaging

Panoramic imaging is an imaging process that produces a panoramic image by using certain probes. The panoramic image provides sequentially and individually aligned B mode images on a static image. The B mode images are real-time, showing their anatomical context of an adjacent structure. Panoramic imaging allows you to display, view and measure a new stitched image constantly.

NOTE:

• Panoramic imaging is only available with linear probes.

• Apply an adequate amount of coupling gel along the intended path of the scan.

• Do not shake, rotate or tilt the probe during the scan.

• Ensure the probe remains to be in contact with the skin perpendicularly during the scan.

• Do not change the scan direction or move the probe backwards and forwards.

• When the scan depth increases, it is generally required to decrease the scan speed.

Perform the following steps to apply real-time panoramic imaging.

Page 107: About This Manual Statement - Creche Innovations

7 Working with Images

Basic User Manual 99

1. Position the B-mode image to the desired scan position.

2. Press the Pan key on the key panel to enter the inactivated Panoramic Imaging mode.

3. Press the Update button on the control panel to enter the real-time panoramic imaging.

4. Perform the scan and the screen will display the real time joint image.

5. Press the button to display the panorama or thumbnail.

FR

D

DRPWR

F

GN

μS

B

Z

7.5

14.0

5075

7.5-10.5

50

31.4

Figure 7-3 Real-Time Panoramic Imaging Screen

6. Work with the image.

a. Zoom in/out the ImageSelect Zoom menu and rotate the corresponding function key to zoom in or out the image, and a thumbnail is displayed in the lower left corner of the screen. Use the trackball to position the interest area.

b. Select Rotate menu and rotate the corresponding function key to rotate the image.c. Select Overview menu and rotate the corresponding function key to restore the

image to the default setting.

d. Make measurements, annotations and body marks. 7. Press the B button to return to B real-time mode image.

7.2 Magnifying an Image

7.2.1 Filling the Full Screen

You can magnify the imaging area to fill the full screen in the real-time or frozen mode.

Page 108: About This Manual Statement - Creche Innovations

7 Working with Images

100 Basic User Manual

NOTE:

Exit the text annotation editing mode before performing this function. For details, refer to Section 7.5.1 Annotating an Image with Typed Words.

Perform the following steps.

1. Press the Z key on the key panel to magnify the imaging area, information bar, and general parameter area into full screen.

2. Press the Z key on the key panel again to magnify the imaging area to fill the full screen.

3. Press the Z key on the key panel again to exit the full-screen display.

7.2.2 Magnifying the Whole Image

You can magnify the whole image in the real-time or frozen mode.

Perform the following steps.

1. Rotate the Zoom button on the control panel to magnify the image.

− A size multiplier is displayed on the general parameters area. − A thumbnail is displayed in the lower left corner of the screen.

2. Use the trackball to select an interest area on the thumbnail.

3. Rotate the Zoom button to adjust the size multiplier.

4. Press the Zoom button to disable this feature.

7.2.3 Magnifying the ROI

You can magnify an interest region on the imaging area in the real time or frozen mode.

The real time B mode is taken as an example in the following steps.

1. Press the Zoom key on the control panel and a zoom box appears on the imaging area.

2. Select Z-Pos or Z-Size by pressing the confirm key.

− When Z-Pos is highlighted, move the trackball to position the zoom box. − When Z-Size is highlighted, move the trackball to adjust the size of the ROI.

3. Press the Zoom or Update key and the selected image area in the zoom box is magnified and displayed in the imaging area.

4. Rotate the Zoom key to zoom in or out the image and move the trackball to view the magnified image.

A size multiplier is displayed on the imaging information area of the basic screen.

5. Press the Zoom key to exit.

Page 109: About This Manual Statement - Creche Innovations

7 Working with Images

Basic User Manual 101

7.3 Freezing an Image

Press the key on the control panel to capture an image in a real time scan, Cine is displayed at lower right corner of the screen, and the feature to be applied is also activated. For the setting, refer to Section 4.1.1 General Settings.

You can select any desired image mode, magnify the image, perform measurement, add

annotations and body marks and adjust imaging parameters in the frozen mode.

7.4 Using Cine

The cine review is available by pressing the key in the real time scan and the progress bar appears on the screen.

You can review the cine and can also cut the desired cine segments.

7.4.1 Reviewing Cine 

■  To Review the Cine Manually

● You can review the cine frame by frame by using the trackball.

● Or, rotate the function key corresponding to F by F to review the cine frame by frame.

Each image is identified by a number which indicates its position in the cine.

NOTE:• You can adjust Rotation, Chroma, GrayMap and μScan parameters when

reviewing a cine.

• You can rotate the function key corresponding to To First or To Last on the menu to review the first or last frame.

■  To Review the Cine Automatically

● Rotate the function key corresponding to Auto Play in the frozen B mode to play or stop the cine review automatically.

● Rotate the function key corresponding to Loop Speed to adjust the review speed during cine review.

● Rotate the function key corresponding to Play Mode to adjust the play sequence during cine review.

7.4.2 Cutting Cine

To cut the cine,

1. Rotate the function key corresponding to Set First to select the start frame in the frozen mode.

Page 110: About This Manual Statement - Creche Innovations

7 Working with Images

102 Basic User Manual

2. Rotate the function key corresponding to Set Last to select the end frame.

3. Press the Cine key on the control panel to save the cut cine.

7.5 Annotations and Body Marks

The annotation feature allows you to type an annotation or add an annotation from the predefined annotation library. Arrows and body marks are also provided to annotate the image.

NOTE:

• You should define an annotation library before applying this feature. For details, refer to Section 4.3 Annotation Settings.

• You can set the default initial position of text annotations and arrow annotations. For details, refer to 4.3.1 Tools Settings.

7.5.1 Annotating an Image with Typed Words

Perform the following steps.

1. Press the Annot key on the control panel in any mode. A green vertical mark appears on the screen. And the predefined annotations appear at the left of the screen.

2. Use the trackball to select the added annotation and select the confirm key to add the annotation to the image. Move the annotation to the desired place by using the trackball.

3. Press the confirm key again to confirm.

4. Repeat the step 2-3 to add more annotations if needed.

You can also perform the following operations when adding an annotation.

− To input an annotation manuallyInput the desired annotation by using the key panel. After finishing, press the confirm key to add the annotation to the image.

− To move an annotationMove the cursor to one annotation. Press the confirm key to activate this annotation and move it to the desired place by using the trackball. Then press the confirm key to confirm.

− To revise an annotation Move the cursor to one annotation and revise it by using the key panel.

5. Press the Annot key again to exit.

7.5.2 Annotating an Image with Arrows

Perform the following steps.

Page 111: About This Manual Statement - Creche Innovations

7 Working with Images

Basic User Manual 103

1. Press the Arrow key on the key panel in any mode, and an arrow displays on the screen.

2. Position the arrow to the desired place by using the trackball.

Rotate the Angle knob to adjust the arrow angle if needed.

3. Press the confirm key to confirm.

4. Repeat step 2-3 to add more arrows if needed.

5. Press the Annot key again to exit.

7.5.3 Body Mark

Perform the following steps.

1. Press the Body Mark key on the control panel in any mode.

Body marks of the selected exam type display on the left of the screen.

2. Select the desired body mark by using the trackball, and press the confirm key to add it to the image.

3. If necessary, rotate the Body mark knob to adjust the angle.

4. Press the Update key to move the body mark to the desired position by using the trackball.

5. Press the confirm key to confirm.

NOTE:

The body mark feature is not available when the display format is set to Full in the PW/M mode.

7.5.4 Deleting Annotations and Body Marks

■  To Delete an Annotation

If an annotation is being edited, you can press the Del key on the control panel to delete this annotation from the screen.

If an annotation has been edited and the system exits the editing status, you can first press the Annot key, move the cursor to the annotation by using the trackball and press the Del key to delete it from the screen.

■  To Delete an Arrow

If an arrow is being edited, press the Del key to delete the last arrow.

If an arrow has been edited and the system exits the editing status, you can first press the Arrow key and press the Del key to delete it from the screen.

Page 112: About This Manual Statement - Creche Innovations

7 Working with Images

104 Basic User Manual

■  To Delete a Body Mark

If a body mark is being edited, press the Del key to delete the body mark on the current image.

If a body mark has been edited and the system exits the editing status, you can first press the Body Mark key and press the Del key to delete it from the screen.

■  To Delete All Annotations and Body Marks

You can press the Clear button on the control panel to delete all annotations and body marks from the image. Perform this deletion with caution.

7.6 ECG Module

By using an optional ECG module (Type BF), 3-channel ECG signals are provided in cardiac applications. During an cardiac application, you can configure the ECG-control so that the ECG trace is displayed at the bottom of the screen.

The ECG cable includes three color-coded ECG electrode connectors: LL (left leg, red), LA (left arm, black), and RA (right arm, white). The ECG module provided by this ultrasound system is for collecting and displaying 3-lead ECG trace.

! ● This ECG module is not suitable for intracardiac use or direct cardiac contact.

● This ECG module provides 3-channel ECG signals, and it cannot be used for diagnosis and monitoring.

● To avoid electrical shock, ensure the ECG cable is intact and correctly connected.

● Conductive parts of electrodes and connectors for ECG should not come into contact with other conductive parts including earth/grounding.

● Stop using the system, if the patient use a pacemaker or implantable cardioverter-defibrillators. This system may interfere with these devices.

● If the ECG waveform is abnormal, check if the ECG cable and electrodes are connected properly.

Perform the following steps.

1. Power off the system, and connect the I/O docking station (optional) to the port of docking station on the left side of the system.

2. Connect the ECG cable to the port of docking station of the system.

3. Power on the system, and attach the ECG electrodes on the patient’s body, as shown in the following figure.

ECG feature is automatically enabled.

Page 113: About This Manual Statement - Creche Innovations

7 Working with Images

Basic User Manual 105

R L

N F

RA LA

RL LL

IEC Standard AHA Standard

I I

II IIIII III

Red

Black

Yellow

Green Green Red

White Black

Figure 7-4 Electrode Placement

4. Make the relevant ECG settings.

a. Press the Menu key on the key panel to activate the menu.b. Click ECG, and ECG parameters are displayed on the screen.c. Rotate the key corresponding to the menu item to adjust the parameters.

Item Description

ECG Gain Set the amplitude of the ECG waveform.

ECG Invert Enable or disable the waveform inversion function.

ECG Position Set the vertical position of the ECG waveform.

ECG Velocity Set the scan speed of ECG signal.

5. Press the key on the control panel to freeze an image, and the ECG waveform is frozen at the same time. Review the ECG waveform frame by frame by using the trackball.

6. Exit the ECG mode, and remove ECG electrodes from the patient.

Page 114: About This Manual Statement - Creche Innovations

T h i s p a g e i s i n t e n t i o n a l l y l e f t b l a n k .

Page 115: About This Manual Statement - Creche Innovations

107

8    Managing Images/Data

Images in this system include frame images and cine, you can save or review them after the acquisition. Meanwhile, images can also be backed up to a USB drive for future review if it is needed.

Page 116: About This Manual Statement - Creche Innovations

8 Managing Images/Data

108 Basic User Manual

8.1 Storing an Image/Cine

The following methods can be used to store images/cines.

Before storing an image or a cine, set the storage time of cine, storage format of file, and pre-defined key for storage. For details, refer to Section 4.1.3 Save Settings.

8.1.1 Storing an Image

Store an image as follows.

● Press the Image key on the control panel in the real time mode or frozen mode to save the current image. Or press the key pre-defined as image storing key to save the screen shot.

● Press the key pre-defined as screen shot to save the current screen shot.

The thumbnails of the stored image will be added to the clipboard.

8.1.2 Storing a Cine

■  Storing a Cine in the Real Time Mode

In the real-time B mode, real time storage is only allowed in the real-time B mode.

● Press the key pre-defined as prospective storage key, and all the frames over the preset time span before the current time will be saved as a cine.

● Press the key pre-defined as retrospective storage key , and all the frames over the preset time span after the current time will be saved as a cine.

The thumbnail of the stored cine will be added to the clipboard.

■  Storing a Cine in the Frozen Mode

Press the key pre-defined as cine key in the frozen mode to save the current cine.

The thumbnail of the stored cine will be added to the clipboard.

8.2 Viewing an Image/Cine

You can view an image or a cine for the current or a previously examined patient by using the clipboard or the Review Exam screen.

8.2.1 Viewing a Current Image/Cine

■  To View an Image/Cine by Using the Clipboard

1. Press the Pointer key in the real time mode or frozen mode.

2. Select an image or a cine in the clipboard at the right of the screen by using the trackball and press the confirm key to view the image/cine.

Page 117: About This Manual Statement - Creche Innovations

8 Managing Images/Data

Basic User Manual 109

− Click the or icon to go to the previous or next clipboard page.

− Click the icon to select all images. − Click the icon to export images to the DICOM server. − Click the icon to export images to a USB drive. − Press the icon to delete the selected image/cine.You can also perform a measurement, magnification and replay while review the cine.

■  To View an Image on the Review Exam Screen

1. Press the Review key on the control panel to enter the Review Exam screen.

The following screen is displayed with images and cine thumbnails.

Review Exam

Patiemt ID: 19700109_092839 Patient Name: Files Number: 19 Exam All Images

2 × 2

Exit

Patient List

Reports

Select All

Delete

Print

DICOM Send

DICOM Print

Export

1 2

3

Figure 8-1 Review Exam Screen

If the patient has had more than one exam, you can select the desired exam from the Exam drop-down list.

2. Move the cursor to the thumbnails by using the trackball and press the confirm key to choose an image. You can delete or print an image, or send an image to the DICOM storage server.

3. After selecting an image, press the confirm key twice to view the image. Press the key to exit.

Page 118: About This Manual Statement - Creche Innovations

8 Managing Images/Data

110 Basic User Manual

8.2.2 Retrieving an Image

Perform the following steps.

1. Select the Patient key > Patient List > Patient View to enter the Patient View screen.

2. Select the desired patient, and then click View to enter the Exam View screen.

3. Select the desired exam, and click View Image to retrieve the image.

8.3 Backing up Data

All data is saved to the system by default. To avoid data loss due to unexpected system breakdown or software update, it is strongly recommended you back up data to a USB drive or DICOM server. For details about DICOM server backup, please refer to Section 9.2 DICOM Storage.

NOTE:

• Complete all exams before backing up the data.

• Please use a legally marketed USB drive ( FAT, FAT32 and NTFS format) to back up the data.

Perform the following steps.

1. Connect a USB drive to the system.

2. Select Patient key to enter Patient List.

3. Select the Patient List > Patient View to select desired patients, and click Export Screen. Then select a USB drive from the drop-down list of USB devices and exported image format.

If you select PC image format, you can also select the exported image, cine or report format.

Export

USB devices:

System

Images:Cines:Report:

BMP JPG TIF

Select File Size:Disk Free Size:

CancelExport

AVI WMV PDF TXT HTML

PC Format

DICOMDIR

4. Click Export to back up the selected patient data to the USB.

Page 119: About This Manual Statement - Creche Innovations

8 Managing Images/Data

Basic User Manual 111

8.4 Importing Data to the System

NOTE:

• Only data generated by this system can be imported.

• Ensure the current exam is completed before you import data. Otherwise, you may have a failure data import.

Perform the following steps.

1. Connect the USB drive to the system.

2. Select the Patient key > Patient List > Patient View to enter the Patient View screen.

3. Click Import Screen.

View Import PatientDelete Patient

Patient ReviewPatient ID

20150505 Mary Unknown 2015/05/05-16:04:03 40.82M

Patient Name Birth Date Sex Exam Time Image Size Status

Import Screen

Patient ID Last Name First Name Age Sex

Date --11/9/2017 11/9/2017

Exit

Reset

Import

Figure 8-2 Import Screen

4. Select a USB drive from the drop-down list and select the imported patient information.

5. Click Import Patient to import the desired data.

Page 120: About This Manual Statement - Creche Innovations

T h i s p a g e i s i n t e n t i o n a l l y l e f t b l a n k .

Page 121: About This Manual Statement - Creche Innovations

113

9    Working with DICOM

DICOM (Digital Imaging and Communications in Medicine) is a standard created by National Electrical Manufacturers Association (ACR-NEMA) to regulate the distribution and viewing of medical images such as ultrasound images and cine.

If the system is configured with the DICOM module, you can:

● Search the archived patient information set on the DICOM server, and copy the patient information to the system so that the correct patient can be examined.

● Search the archived patient information on the other ultrasound system and copy the patient information to the system so that the correct patient can be examined

● Send stored images or data on the system to the DICOM server.

● Print images on a DICOM printer.

DICOM service of the system consists of DICOM storage, structured report, DICOM print, DICOM worklist, query/retrieve list, MPPS storage commitment and DICOM queue.

If you need DICOM 3.0 Compatibility Declaration, please contact the manufacturer.

Page 122: About This Manual Statement - Creche Innovations

9 Working with DICOM

114 Basic User Manual

9.1 Verifying Connectivity

Perform the following steps.

1. Connect the system to the local DICOM network server by using a network cable.

2. Edit the relative settings for the local network and DICOM server. For details, refer to Section 4.7.2 Network Settings and Section 4.8 DICOM Settings.

3. After the verification is successful, you can use the DICOM services.

NOTE:

Ensure the system is connected to the server before using the DICOM service. Otherwise, the service cannot be used.

9.2 DICOM Storage

DICOM Storage is used to send patient data to the DICOM storage server for storage.

9.2.1 To Store the Current Image

1. Click the checkbox beside Send image to DICOM storage on the SystemSettings screen > General menu > Save tab.

2. Select the Image key or the predefined key in the real-time or frozen mode to send the current image to the DICOM storage server.

9.2.2 To Store the Current Cine

1. Click the checkbox beside Send cine to DICOM storage on the SystemSettings screen > General menu > Save tab.

2. Select the cine key or the predefined key in the frozen mode to send the current cine to the DICOM storage server.

9.2.3 To Store Patient Data

1. Select the Patient key > Patient List > Patient View to enter the Patient View screen.

2. Select the desired patient, and then click View to enter the Review Exam screen.

3. Select the desired exam.

4. Click DICOM Send to send the patient data to the DICOM storage server.

If you only want to send images or DICOM structured report, click View Image to enter the Review Exam screen, select the desired images or cines, and then click DICOM Send.

If you want to check the status of items sent to the DICOM storage server, choose the Patient key > Patient List > DICOM Queue.

Page 123: About This Manual Statement - Creche Innovations

9 Working with DICOM

Basic User Manual 115

9.3 DICOM Print

DICOM Print is used to send images to the DICOM print server for printing.

You should properly connect the system to the print server and edit the relevant settings. For details, refer to Section 4.8 DICOM Settings.

1. Choose the Patient button > Patient List > Patient Review to enter the Patient Review screen.

2. Select the desired patient, and then click View to enter the Exam Review screen.

3. Select the desired exam.

4. Click DICOM Print to send the patient information and the relevant images to the DICOM print server.

If you only want to print images, press the Review button on the control panel to enter the View Image screen, select the desired images and then click DICOM Print  to print the image.

If you want to check the status items sent to the DIOCM print server, choose Patient button > Patient List > DICOM Queue.

9.4 DICOM Worklist

The DICOM Worklist is used to search the archived patient information on the DICOM server, and copy the patient information to the system so that the correct patient can be examined.

Press the Patient button on the control panel to enter the New Patient screen and then click WorkList to enter the WorkList screen.

Page 124: About This Manual Statement - Creche Innovations

9 Working with DICOM

116 Basic User Manual

WorkList

WorkList Information

Patient ID Last Name Accession#

Requested Procedure IDDate --11/09/2017

Patient ID Patient Name Birth Date Sex Description Requested Procedure ID Accession# Date Time

Search

Reset

Start ExamSelect Cancel

11/09/2017

First Name

Only US

Figure 9-1 WorkList Screen

Perform the following steps.

1. Search for the patient information.

Enter the search requirements, such as Patient Name, Patient ID, Accession#, Exam Date/Time or Requested Procedure ID, and then click Search to search for the desired information.

Clicking Reset can clear all the search information.

Clicking Date/Time can display the patient data by order of oldest or newest input date/time.

2. Start an exam.

Select the desired patient.

− Click Select to enter New Patient screen. Input patient information and select Application.

− Click Start Exam to start an exam.

9.5 Query/Retrieve List

The DICOM Query/Retrieve List is used to retrieve patient information from other ultrasound systems, and copy the retrieved patient information to the system for examination.

Press the Patient key on the control panel to enter New Patient list. Click Patient List to enter Patient List screen and click DICOM Q/R to enter the Query/Retrieve List screen.

Page 125: About This Manual Statement - Creche Innovations

9 Working with DICOM

Basic User Manual 117

Query/Retrieve List

Patients

Exam TypeABD

Last Name

Accession#

Patient ID First Name

Date --10/22/2017

Patient ID Patient Name Birth Date Exams Sex Last Exam

Exams

Patient ID Accession#NO. Exam Time Img Exam Size

Query Patients

Query Exams

Retrieve Images

Import

Exit

ResetOnly Us10/22/2017

0/0P

Figure 9-2 Query/Retrieve List

Perform the following steps.

1. Retrieve patient information

Select the desired query condition, such as Patient ID, and input related information. Click Query Patient, and matching patient information will be displayed on the patient list.

Click Reset to delete the entered query condition.

Click Last Exam, the system will arrange the patient information in chronological order of exams.

2. Retrieve exam types

Select the desired patient information on the patient list and click Query Exam. Exam types of the patient will be displayed on the exam list.

Click Exam Time, the system will arrange the exam types in chronological order of exams.

3. Retrieve images

Select an exam type from the exam list. Click Retrieve Images, and images and cines saved in this exam type will be displayed on the image and cine box on the bottom of the screen.

4. Import patient information

Page 126: About This Manual Statement - Creche Innovations

9 Working with DICOM

118 Basic User Manual

a. Move the cursor to the desired image or cine, and press the confirm key.Click the or icon to go to the previous or the next page of the image and cine box. Click the icon to select all images or cines.

b. Select desired exam type from the Exam Type drop-down list and click Import.The selected patient information and the corresponding images or cines will be imported into the system.

9.6 MPPS

MPPS is used to send exam status information to the MPPS server, which facilitates the other systems to obtain the exam progress in time.

The status information is described as below:

● When the exam is started, the system sends the status information “In Process” to the MPPS server.

● When the exam is completed by pressing the End Exam button on the control panel, the system sends the status information Complete or Discontinue to the MPPS server.

If you want to check the status items sent to the MMPS server, choose the Patient button > Patient List > DICOM Queue.

You can add MPPS manually to check the processing status of the discontinued exam or other order operations.

NOTE:

MPPS can only be added when you perform the scan or other order operations.

Perform the following steps.

1. Choose the Patient button > Patient List to enter the Patient Review screen.

2. Click PPS Screen to enter the PPS screen.

Page 127: About This Manual Statement - Creche Innovations

9 Working with DICOM

Basic User Manual 119

PPS Screen

Information

Patient ID Patient Name BirthDate Sex Description Start Time StateEnd time

CompletedExit DiscontinueAppend

Figure 9-3 PPS Screen

The PPS screen displays MPPS information about the current patient.

− Click Discontinue to suspend the current exam. − Click Completed to end the current exam. − Click Append to restart the exam..

9.7 Storage Commitment

Storage commitment is used to confirm whether the images or structured reports are successfully stored to the DICOM storage server.

If you want to check the status of items sent to the DICOM storage server, choose the Patient key > Patient List > DICOM Queue.

9.8 DICOM Queue

The DICOM Queue is used to check the sending status of DICOM storage.

Select the Patient key > Patient List > DICOM Queue to enter the DICOM Queue screen.

Page 128: About This Manual Statement - Creche Innovations

9 Working with DICOM

120 Basic User Manual

DICOM Queue

DICOM Queue Information

Patient ID Last Name Type

Date --11/09/2017

Type Patient ID Patient Name Server Start Time Size Run State Status Details

Reset

ResendResend Fail DeleteExit Refresh All Select

11/09/2017

First Name

Figure 9-4 DICOM Queue Screen

Perform the following steps.

1. Search for the patient information

Enter the search requirements, such as Patient ID, Patient Name, Type or Date, and the desired information is displayed in the list.

2. Check the sending status

You can check the sending status by viewing Run State, Status or Details.

3. Deal with the failure sending information

− Select the desired patient information and click Refresh. If it does not work, you can click Resend to resend the information.

− Click Resend Fail to resend all information.

− Select the desired patient information and click Delete to delete the sending status.

Page 129: About This Manual Statement - Creche Innovations

121

10    Probes and Biopsy Brackets 

You should become thoroughly familiar with the operations of the probe and biopsy bracket before using them. To ensure the performance of the probe and the biopsy bracket, you should periodically check, clean, disinfect and maintain them.

Page 130: About This Manual Statement - Creche Innovations

10 Probes and Biopsy Brackets

122 Basic User Manual

NOTE:

A general instruction for the probe and biopsy bracket is provided in this manual. For details, refer to the relevant manuals.

10.1 Probe

This system supports a wide range of probes which make the system remarkably versatile.

The schematic diagrams of probes are as follows.

Transducer

Transducer

Orientation Mark

Junction Line

Junction LineHandle

Body Surface Probe Endocavitary Probe

Handle

10.1.1 Available Probes

The available probes are listed as follows.

Probe Model  Application

L741, 3C-A, 3P-A,7P-B, 12L-B, C613, PWD2.0, 12LI-A, 10I2, 6CT-A

Body surface

6V1, 6V3, EC9-5 Intracavitary

Page 131: About This Manual Statement - Creche Innovations

10 Probes and Biopsy Brackets

Basic User Manual 123

10.1.2 Probe Usage

! ● Use only the probes provided by the manufacturer. Otherwise, the system may not

perform and an accident such as a fire may result.

● Use the probe carefully. If any part of the probe surface is scratched, immediately stop using the probe. Otherwise, electrical shock may occur.

● A legally marketed probe sheath is required for intracavitary operations. If lubricant is used, it must be water-soluble. Do not apply coupling gel directly on the patient’s skin. Please dispose of the sheath in accordance with local laws and regulations.

● Use a sterile probe sheath and sterile coupling gel when performing an intraoperative, trans-vaginal, trans-rectal or trans-esophageal (Cardiac) exam. If lubrication is insufficient because of age and personal reason during the exam, you need to apply a sufficient amount of sterile coupling gel on the surface of the sheath.

● To avoid contamination, please use the coupling gel and probe sheath before performing an exam.

● Use legally marketed coupling gel in accordance with relevant local regulations. Read and understand all precautions in the relevant manual of the coupling gel before use. For recommended coupling gels, please refer to Appendix D.1 Coupling Gel.

● Latex or natural rubber contained inside medical equipments or accessories can cause severe anaphylactic reactions in some individuals. It’s suggested by the FDA that the operator should identify latex-sensitive patients and be prepared to treat anaphylactic reactions promptly.

● After being contaminated by pathogenic bacterium that is hard to kill, such as cryptosporidium or prion virus, the probe and its accessories should be destroyed by melting or burning when necessary because they cannot be completely disinfected or sterilized.

● Avoid immersing the transducer surface in the coupling gel for a long period of time. Otherwise, damage to the probe may occur.

● Avoid any fluid flowing into the probe or probe connector when cleaning, disinfecting or sterilizing the probe and probe cable.

■  Special Concerns before Probe Usage

Inspect the probe before each use. If the following damage is found, stop using the probe immediately.

● Cracks on the probe handle (user section).

● Cracks on the transducer surface (applied section).

● Scratches on the transducer surface (acoustic window surface).

Page 132: About This Manual Statement - Creche Innovations

10 Probes and Biopsy Brackets

124 Basic User Manual

● Swelling of the acoustic window material.

● Cracks or wear on the probe cable.

● Cracks on the probe connector or any other kinds of visible damage.

● Deformed pins or broken pins inside the probe connectors.

● Damage or deformation on the probe cable.

■  Body Surface Probe Usages

1. Wear sterile medical gloves.

2. Orient the probe.

3. Perform a scan.

■  Endocavitary Probe Usages

1. Wear sterile medical gloves.

2. Cover the probe with the probe sheaths (only for the endocavitary probes).

a. Remove the packaging and unfold the probe sheath.b. Apply an appropriate amount of coupling gel to the inside of the sheath and onto

the face of the probe.

c. Hold the probe and unroll the sheath onto the probe.d. Pull the probe sheath tightly over the face of the probe to remove wrinkles.e. Secure the sheath to the probe with the adhesive tapes or elastic bands.

3. Orient the probe

Check the probe orientation mark before the scan.

4. Perform a scan.

Page 133: About This Manual Statement - Creche Innovations

10 Probes and Biopsy Brackets

Basic User Manual 125

10.1.3 Cleaning the Probe

! ● To avoid electrical shock, disconnect the probe from the system before cleaning.

● To avoid potential disease transmission, you should wear sterile medical gloves and protective goggles while cleaning.

● Do not use the cleaner that contains sodium sulfate and/or sodium hypochlorite to clean the probe. Otherwise, the probe may be damaged.

● To avoid probe damages, do not bump the probe on hard surfaces.

● Use only the cleaner recommended by the manufacturer to clean the probe. Otherwise, the probe may be damaged.

You should clean the probe before and after each use. Probe cleaning is an essential step of the disinfection and sterilization.

Perform the following steps to clean the probe.

1. Remove the coupling gel from the probe surface after exam.

2. Disconnect the probe from the system and remove the probe sheath and biopsy bracket from the probe.

3. Use a lint-free soft cloth dampened with mild soapy water or the recommended cleaner (see Appendix D.2 Cleaner) to wipe the probe.

If there are dried stains on the surface or in the grooves of the probe, remove them by a brush dampened with an enzymatic clearer.

4. Rinse the surfaces of the probe with the fresh running water to completely remove any residual cleaner.

5. Dry the probe with a lint-free soft dry cloth.

Page 134: About This Manual Statement - Creche Innovations

10 Probes and Biopsy Brackets

126 Basic User Manual

10.1.4 Disinfecting or Sterilizing the Probe

! ● There is a cleared list of sterilants and high-level disinfectants for use in processing

reusable medical and dental devices on the FDA website. That list can be consulted to find agents that may be useful for probe disinfection. Please refer to the following URL for FDA-Cleared Sterilants and High Level Disinfectants: http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/ReprocessingofSingle-UseDevices/ucm133514.htm.

● Use the liquid disinfectant/sterilant that meets local laws and regulations or the recommended disinfectant/sterilant.

● The probe sheath may be damaged during exam and contamination risk level caused by the damaged sheath is difficult to estimate. Therefore, probe sheath cannot change the level of disinfection for a probe. Please clean and sterilize (or high level disinfect) the endocavitary probe and clean and sterilize the probe for biopsy and coming into contact blood after exam.

● Do not use an expired disinfectant/sterilant.

● Store the probe in a sterile environment, and review its expiration date before use.

● If you use the recommended disinfectant/sterilant, ensure the requirements for the disinfection level and probe soaking period are met. Otherwise, the probe could be damaged and your warranty might be void. If you have further use or needs for the probe, ensure the level of the make-up disinfectant/sterilant and the probe soaking period are suitable for the intended clinical application.

● Do not use the following methods to sterilize the probe.

− Autoclave

− Ultraviolet sterilizer

− Gamma ray sterilizer

− Ethylene oxide gas

− Ethylene oxide

− Thermal disinfection/sterilization. Temperature higher than 66°C (150°F) will damage the probe.

● Do not allow any disinfectant/sterilant to be air-dried on the probe.

■  Disinfection Levels

To choose an appropriate disinfectant, you must first determine the required level of disinfection, based on the probe classification.

Page 135: About This Manual Statement - Creche Innovations

10 Probes and Biopsy Brackets

Basic User Manual 127

Classification Definition Level of Disinfection Application

Critical A device that enters normally sterile tissue or the vascular system.

Sterilization Intraoperat ive , b i o p s y u s e o r blood contacting probe

Semi-critical A device that comes into contact with intact mucous membranes and does not ordinarily penetrate sterile tissue.

High-level disinfection E n d o c a v i t a r y probe

Noncritical Devices that do no ordinarily touch the patient or touch only intact skin.

Medium or low-level disinfection

B o d y s u r f a c e probe

■  Soaking Requirements

Do not immerse the probe beyond its junction line.

■  To Disinfect the Body Surface Probe

You should disinfect the body surface probe after each use.

Perform the following steps.

1. Clean the probe.

For details, refer to Section 10.1.3 Cleaning the Probe.

2. Perform the medium-level disinfection to the probe as shown in Table 10-1.

Or select a recommended disinfectant (see Appendix D.3) to disinfect the probe by following the instruction provided by disinfectant’s manufacturer.

3. Rinse the probe with fresh running water to completely remove the residual disinfectant.

4. Dry the probe with a lint-free soft dry cloth.

Page 136: About This Manual Statement - Creche Innovations

10 Probes and Biopsy Brackets

128 Basic User Manual

Table 10-1 Recommended Method for Medium-level Disinfection

Disinfectant Manufacturer ActiveIngredient

Level for Active Ingredient

ContactType

ContactPeriod

70% Isopropyl alcohol

ALL 70% Isopropyl alcohol

70% Spray/Wipe

<10 minutes

T-spray II Pharm. Inc. Quat. Ammonia

/ Spray/Wipe

<10 minutes

T-spray Pharm. Inc. Quat. Ammonia

/ Spray/Wipe

<10 minutes

■  To Disinfect the Endocavitary Probe

You should disinfect the endocavitary probe before and after each use.

Perform the following steps.

1. Clean the probe.

For details, refer to Section 10.1.3 Cleaning the Probe.

2. Perform the high-level disinfection to the probe as shown in Table 10-2.

Or select the recommended disinfectant (see Appendix D.3) to disinfect the probe by following the instruction provided by disinfectant’s manufacturer.

3. Rinse the probe with running sterile water to completely remove the residual disinfectant.

4. Dry the probe with a lint-free soft dry cloth.

Table 10-2 Recommended Method for High-level Disinfection

Disinfectant Manufacturer Active Ingredient

Level for Active Ingredient

ContactType

ContactPeriod

Cidex™ Activated

Dialdehyde Solution

J&J Glutaraldehyde 2.4% Soak 45-50 minutes

Resert XL HLD

STERIS 2.0% H2O2 2.0% Soak 8 minutes

Page 137: About This Manual Statement - Creche Innovations

10 Probes and Biopsy Brackets

Basic User Manual 129

10.1.5 Sterilizing the Probe

You should sterilize the intraoperative, biopsy use probe or any probe that comes into contact with blood after each use.

Perform the following steps.

1. Clean the probe.

For details, refer to Section 10.1.3 Cleaning the Probe.

2. Sterilize the intraoperative probe as shown in Table 10-3.

Or select the recommended disinfectant (see Appendix D.3) to sterilize the probe by following the instruction provided by disinfectant’s manufacturer.

3. Rinse the probe with running sterile water to completely remove the residual sterilant.

4. Dry the probe with a lint-free soft dry cloth.

Table 10-3 Recommended Method for Sterilization

Disinfectant Manufacturer Active Ingredient

Level of Active Ingredient

Contact Type

Contact Period

C i d e x ™ Activated

Dialdehyde Solution

J&J Glutaraldehyde 2.4% Soak 1 0 hours

10.1.6 Disinfecting and Sterilizing the Probe Cable

!To avoid potential disease transmission, you should wear sterile medical gloves and protective goggles during disinfection or serialization.

Do not immerse the probe cable in alcohol or isopropyl alcohol at any concentration for a long period of time. Avoid any contact with iodine or phenols. Otherwise, it will accelerate the aging of the cable and decrease the service time of the probe, or even result in cable damages.

■  Disinfection

Perform the following steps to disinfect the probe cable.

1. Use a lint-free soft dry cloth dampened with mild soapy water to wipe the probe cable.

2. Rinse the cable with fresh running water to completely remove the residual cleaner.

3. Perform the medium-level disinfection to the probe cable as shown in Table 10-4.

Page 138: About This Manual Statement - Creche Innovations

10 Probes and Biopsy Brackets

130 Basic User Manual

4. Rinse the surfaces of the probe cable with fresh running water to completely remove the residual disinfectant.

5. Dry the probe cable with a lint-free soft dry cloth.

Table 10-4 Recommended Method for Medium-level Disinfection

Disinfectant Manufacturer Active Ingredients

Level of Active Ingredients

Contact Type

Contact Period

T-spray II Pharm. Inc. Quat. Ammonia

/ Spray/Wipe

<10 minutes

T-spray Pharm. Inc. Quat. Ammonia

/ Spray/Wipe

<10 minutes

■  Sterilization

If the probe cable comes into contact with any blood or body fluid, you should sterilize it. For details, refer to the information about probe sterilization.

10.1.7 Storage and Transportation

You should store or transport the probe in accordance with Appendix A Specifications.

■  To Store the Probe

Follow the following items to store the probe.

● Store the probe in a probe holder or specific package when not in use.

● Ensure the probe holder is clean before storing it.

● To avoid contaminating the package, disinfect or sterilize the probe before storage or store it in a disposable probe package.

● Do not expose it to direct sunlight or sudden environmental temperature changes.

● Store the probe alone to avoid any impact on the probe head.

● Carefully wind the probe cable.

● Dry the probe before storing it.

■  To Transport the Probe

Perform the following steps to transport the probe.

1. Clean and disinfect the probe before transportation.

2. Place the probe fully into the carrying case and carefully wind the cable.

3. Close the cover of the carrying case.

4. Pack the carrying case with sponge and place it in a carton.

Page 139: About This Manual Statement - Creche Innovations

10 Probes and Biopsy Brackets

Basic User Manual 131

10.2 Biopsy

You should properly assemble and verify the biopsy bracket before performing a biopsy.

! ● Only use the biopsy bracket in conjunction with the probe provided by the

manufacturer. Otherwise, the system and probe may be damaged, an accident such as a fire may result in the worst case.

● Only trained physicians or sonographers under ultrasound guidance can handle the biopsy needle guides. During operation, the operator must observe the proper needle insertion sequencing with the needle guide in order to avoid undue discomfort and unnecessary risk and injury to the patient.

● The biopsy guidelines that display on the monitor are intended as a reference. It is the operator’s responsibility to verify the correct positioning of the needle during a biopsy.

● Do not use a needle guide if the path of the needle is not accurately indicated by the on-screen guidelines. The path of the needle must be displayed within the guidelines. Contact the manufacturer or the local distributer if the needle path is not accurately indicated.

● Do not freeze an image when performing a biopsy.

● To avoid hurting the patient accidentally, the operator should be highly focused during a biopsy.

● You should activate the biopsy guidelines before performing a biopsy.

● The biopsy needle is disposable.

● To avoid infection, disinfect the probe and cover it with the probe sheath when performing a biopsy.

● To avoid possible personnel injury, the operator should perform the biopsy using an appropriate biopsy bracket.

10.2.1 Available Biopsy Brackets

BiopsyBracket Model

AvailableProbe Model

Available Biopsy Needle  Application

NGBC613 C613 14G, 16G, 18G, 20G, 22G Body surface

NGB3C-A 3C-A 14G, 16G, 18G, 20G, 22G Body surface

NGBL741 L741 14G, 16G, 18G, 20G, 22G Body surface

NGB12L-B 12L-B 14G, 16G, 18G, 20G, 22G Body surface

NGB3P-A 3P-A 14G, 16G, 18G, 20G, 22G Body surface

Page 140: About This Manual Statement - Creche Innovations

10 Probes and Biopsy Brackets

132 Basic User Manual

BiopsyBracket Model

AvailableProbe Model

Available Biopsy Needle  Application

NGB6V3 6V3 16G, 18G, 20G, 22G Intracavitary

NGB6V1 6V1 16G, 18G, 20G, 22G Intracavitary

NGBEC9-5 EC9-5 16G, 18G, 20G, 22G Intracavitary

10.2.2 Assembling the Biopsy Bracket

■  To Assemble the Surface Biopsy Bracket

Tube Holder

Fixing Bracket

Protrusion

Biopsy Guide Tube

Perform the following steps.

1. Wear sterile gloves.

2. Unfold the probe sheath, and apply an appropriate amount of coupling gel into the sheath and onto the face of the probe.

3. Hold the probe and unroll the sheath onto the probe. Pull the probe sheath tightly over the face of the probe to remove any wrinkles.

4. Align the biopsy bracket with the orientation mark of the probe.

5. Attach the biopsy bracket to the probe and apply four protrusions with firm pressure. Ensure the biopsy bracket is firmly attached to the probe.

Orientation Mark

Page 141: About This Manual Statement - Creche Innovations

10 Probes and Biopsy Brackets

Basic User Manual 133

6. Place the biopsy guide tube into the tube holder.

7. Insert the biopsy needle into the tube.

8. Unfold another probe sheath, and apply an appropriate amount of coupling gel to the inside of the sheath.

9. Hold the probe attached with the biopsy bracket and unroll the sheath onto them.

■  To Assemble the Endocavitary Biopsy Bracket

Inner PartFixing Bracket

Locking Screw

Top Housing

Perform the following steps.

1. Wear sterile gloves.

2. Unfold the probe sheath, and apply an appropriate amount of coupling gel to the inside of the sheath and onto the face of the probe.

Page 142: About This Manual Statement - Creche Innovations

10 Probes and Biopsy Brackets

134 Basic User Manual

3. Hold the probe and unroll the sheath onto the probe. Pull the probe sheath tightly over the face of the probe to remove wrinkles.

4. Slide the inner part into the top housing and push forward until it clicks.

5. Align the biopsy bracket with the orientation mark of probe.

Orientation Mark

6. Attach the biopsy bracket to the probe and fasten the biopsy bracket with the locking screw.

7. Insert the biopsy needle into the tube and ensure the biopsy bracket is firmly attached to the probe .

Page 143: About This Manual Statement - Creche Innovations

10 Probes and Biopsy Brackets

Basic User Manual 135

8. Unfold another probe sheath, and apply an appropriate amount of coupling gel to the inside of the sheath.

9. Hold the probe attached with the biopsy bracket and unroll the sheath onto them.

10.2.3 Preparing for a Biopsy

!Before and after using a rectal or transvaginal probe to perform a biopsy, you should clean and sterilize the probe and all the biopsy accessories. Otherwise, it may cause a infection risk to the next patient who uses the probe and accessories.

You should prepare the following items before performing a biopsy.

● New, straight, biopsy needle

● Sterilized container of sterile and degassed water

● Probe attached with biopsy needle

● Activated biopsy guidelines

● Sterile probe sheath

10.2.4 Verifying the Biopsy Bracket

NOTE:

Ensure the biopsy bracket is properly attached to a compatible probe before verification.

Perform the following steps.

1. Select the Biopsy key on the key panel in the real-time B mode.

2. Immerse the probe (the part that is not beyond the junction line) in the degassed water.

3. Insert the biopsy needle into the maximum depth of the water.

4. Verify that the path of the needle is displayed according to the guidelines shown on the image screen. After verification, the needle guide is ready for use.

Page 144: About This Manual Statement - Creche Innovations

10 Probes and Biopsy Brackets

136 Basic User Manual

10.2.5 Performing a Biopsy

NOTE:

Ensure the biopsy bracket is properly attached to the compatible probe and be verified before you perform a biopsy.

Perform the following steps.

1. Choose Setup > General > Biospy > Biopsy Guide Line, set Biopsy Angle and Guide Line Type, and then set Guide Line Display to On. For details, refer to Section 4.1.4 Biopsy Settings.

2. Select the Biopsy key on the key panel in the real-time B mode.

You can set the biopsy angle and the size of dots for the guideline.

− Rotate the function key corresponding to Biopsy to select a biopsy angle. − Rotate the function key corresponding to Dot Size to adjust the size of dots for the guideline.

NOTE:You can press the Menu key on the key panel to activate the menu area, and click Imaging Parameters or Biopsy to switch to corresponding parameter menu.

3. Perform a scan to locate the target.

4. Perform the puncture by sliding the needle through the groove in the guide until the needle, as shown on the display, intercepts the target.

You can rotate the function knob corresponding to Biopsy Cali. to On to adjust the biopsy guideline.

− Rotate the function key corresponding to Angle to adjust the angle of the biopsy guideline freely.

− Rotate the function key corresponding to Offset to adjust the position of the biopsy guideline gradually.

− Rotate the function key corresponding to Save to save settings of the biopsy guideline.

− Rotate the function key corresponding to Load Default to restore the preset angle and the default position of the biopsy guideline.

5. Adjust the brightness of the biopsy needle on the image.

For linear probes, rotate the function key corresponding to Vis-Needle to On to enhance the brightness for the biopsy needle.

Page 145: About This Manual Statement - Creche Innovations

10 Probes and Biopsy Brackets

Basic User Manual 137

a

Biopsy Needle

Biopsy Enhanced Region LineUltrasound Image

Press the function key corresponding to SteerAngle and rotate the function key to adjust the angle of the biopsy enhanced region line. Angle a becomes more closely to 90°, and brightness of the biopsy needle becomes more stronger.

6. Gently remove the probe from the patient after completing the biopsy.

10.2.6 Cleaning the Biopsy Bracket

! ● Clean the biopsy bracket after each use.

● Wear sterile medical gloves and protective goggles during cleaning.

Perform the following steps.

1. Disconnect the probe from the system, and remove the biopsy bracket and biopsy guide tube from the probe.

2. Brush and rinse the bracket with enzymatic cleaner to remove any residue.

3. Dry the bracket with a lint-free soft dry cloth.

10.2.7 Sterilizing the Biopsy Bracket

! ● Disinfect the biopsy bracket after each use.

● Use the liquid sterilant that meets local laws and regulations.

● If you use the recommended sterilant, ensure the requirements for the sterilant level and biopsy bracket soaking period are met. Otherwise, the biopsy bracket could be damaged and your warranty may be void. If you have further use or needs for the probe, ensure the level of the make-up sterilant and the biopsy bracket soaking period are suitable for the intended clinical application.

● Do not use the expired sterilant.

● If you use other contact type to sterilize the biopsy bracket, ensure it is guaranteed by the manufacturer or the local distributer.

● Do not sterilize the biopsy bracket with ethylene oxide.

● Do not allow any sterilant to be air-dried on the biopsy bracket.

Perform the following steps.

Page 146: About This Manual Statement - Creche Innovations

10 Probes and Biopsy Brackets

138 Basic User Manual

1. Clean the biopsy bracket.

For details, refer to Section 10.2.6 Cleaning the Biopsy Bracket.

2. Sterilize the biopsy bracket as shown in Table 10-5 for the entire recommended soaking period.

3. Rinse the bracket with running sterile water to completely remove the residual sterilant.

4. Dry the bracket with a lint-free soft dry cloth.

Table 10-5 Recommended Method for Sterilization

Sterilant Manufacturer Active Ingredients

Level for Active Ingredient

Contact Type

Contact Period

Cidex™ Activated Dialdehyde Solution

J&J Glutaraldehyde 2.4% Soak 10 hours

10.2.8 Storage

Ensure the biopsy bracket is cleaned, sterilized and completely dried before storing it. Store the biopsy bracket in a sterile environment and keep it away from the environment of sudden temperature changes or direct sunlight.

Page 147: About This Manual Statement - Creche Innovations

139

11    System Maintenance

To maintain the safety and functionality of the system, periodically perform the maintenance for the system and accessories.

Page 148: About This Manual Statement - Creche Innovations

11 System Maintenance

140 Basic User Manual

! ● To avoid electric shock and damage to the system, power off and unplug the system

from the AC power outlet before cleaning.

● To maintain the safety and functionality of the system, maintenance must be performed at least once every year. Electrical safety tests must also be performed at regular intervals as specified by local safety regulations.

11.1 Cleaning the System

11.1.1 To Clean the System Surface

1. Power off and unplug the system from the AC power outlet.

2. Dampen a lint-free soft cloth with 75% ethyl alcohol.

3. Use this lint-free soft cloth to clean the surfaces of the monitor screen and the control panel.

4. Use a cotton swab to remove solids from between keys and controls.

5. In case of blood or any infectious fluids or materials, use a lint-free soft cloth dampened with 70% isopropyl alcohol.

11.1.2 To Clean the Trackball

1. Power off and unplug the system from the AC power outlet.

2. Press the bulges in the ring with both hands.

3. Turn the ring anticlockwise until the ring lifts.

4. Take out the ring and trackball (be careful not to drop the trackball) from the control panel.

5. Use a lint-free soft cloth dampened with 75% ethyl alcohol to clean the trackball.

6. Use a cotton swab dampened with 75% ethyl alcohol to remove stains from the ring.

7. Place the trackball and the ring back in the control panel, press the bulges in the ring with both hands and turn the ring clockwise to install the trackball.

Page 149: About This Manual Statement - Creche Innovations

11 System Maintenance

Basic User Manual 141

11.2 Maintenance Checks

To maintain the safety and functionality of the system, the following maintenance checks must be performed by service personnel at least every 1 year.

11.2.1 Electrical Safety

● Integrity of power cable

● Protective conductor resistance

● Patient leakage current

● Patient auxiliary leakage current

11.2.2 Battery Safety 

Check the intactness and performance of the battery.

● Battery Appearance

Ensure there is no bulge, crack, damage, leakage or corrosion.

● Battery Performance

a. Connect the AC adaptor to the system to fully charge the battery.b. Disconnect the AC adaptor from the system, and then run the system with the fully

charged battery until the system automatically shuts down. c. The discharge period of the battery indicates the battery performance. If the

discharge period is less than 30 minutes, you should replace the battery or contact the service department of the manufacturer.

11.2.3 Mechanical Safety

● Appearance of the system enclosure

● Appearance of the control panel

NOTE:The surfaces of the control panel may be abrasive because of the split liquid or other cleaning sprays. Check the potential problems carefully when performing maintenance checks.

● Connectivity of interfaces

11.2.4 Image Recording

● Images in each mode

● Image recording using the standard probe

11.3 Troubleshooting

Q1: The system cannot be powered on.

Page 150: About This Manual Statement - Creche Innovations

11 System Maintenance

142 Basic User Manual

A1: Check whether the battery is exhausted, or whether the system is correctly connected to the mains supply.

Q2: No images are displayed on the LCD monitor.

A2: Check whether the power supply cable is well connected.

Q3: The LCD monitor displays abnormal.

A3: Check whether the appropriate probe and compatible exam type are selected, or the imaging parameters are optimized correctly.

Q4: The system crashed or cannot be normally powered off

A4: Press and hold the button for more than 5s to power the system off.

If any of the above problems still exist, please contact the Customer Service Department of the manufacturer for help.

11.4 Equipment Disposal

Date of manufacture is located on the product label. Under normal conditions, the service life of the probe is about twenty-five thousand hours. Once the time expires, you should dispose of it in accordance with local laws or regulations.

You should dispose of the main unit, the probe, the biopsy bracket and other accessories in accordance with local laws and regulations.

For the detailed disposal information, consult the manufacturer or the local distributor. The manufacturer is not responsible for any system content or accessories that have been discarded improperly.

11.5 Customer Service

Only the service personnel of or authorized by the manufacturer can service the system. Any feedback or inquires concerning our product or services should be directed to the following address.

Address: 4/F, 5/F, 8/F, 9/F & 10/F, Yizhe Building, Yuquan Road, Nanshan, Shenzhen, 518051, Guangdong, China

Zip Code: 518051

Tel: +86 755 2672 2890

Fax: +86 755 2672 2850

E-mail: [email protected]

Page 151: About This Manual Statement - Creche Innovations

143

Appendix  A  Specifications

Comply with EN 60601-1 (IEC 60601-1), Medical electrical equipment Part 1: General requirements for basic safety and essential performance

EN 60601-2-37 (IEC 60601-2-37), Medical Electrical Equipment Part 2-37: Particular Requirements for the Basic Safety and Essential Performance of Ultrasonic Medical Diagnostic and Monitoring Equipment

EN 60601-1-2 (IEC 60601-1-2), Medical Electrical Equipment Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests

Classifications Type o f p ro t ec t i on a g a i n s t e l e c t r i c a l shock

Class I ME equipment (with Adaptor);

Internally Powered ME equipment (when not connected to supply mains)

Degree of protection against electrical shock

Type-BF applied part

Installation Type Portable equipment

Degrees of protection a g a i n s t h a r m f u l liquid

● System is IPX0

● Probe (from the acoustic window to the junction line) is IPX7

● Foot switch is IPX8

A c c o r d i n g t o t h e degree of safe ty of application

The equipment is not suitable for use in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.

Environmental

Requirement

Operations Storage and Transportation

Relative Humidity 30%-85%

(no condensation)

20%-90%

(no condensation)

Ambient Temperature 0°C to +40°C -20°C to +55°C

Atmospheric Pressure 700hPa-1060hPa 700hPa-1060hPa

Power supply AC/DC Adaptor:

Input: 100-240Va.c., 1.5-0.75A, 50-60Hz; Output: 19Vd.c., 4.74A

Main unit: 19Vd.c., 4.74A

Applied Parts Probe, ECG electrodes

Page 152: About This Manual Statement - Creche Innovations

144

Appendix  B  EMC Guidance and Manufacturer’s Declaration

B.1  Electromagnetic EmissionsThe equipment is intended for use in the electromagnetic environment specified below. The customer or the user of the EQUIPMENT should assure that it is used in such an environment.

Emissions Test Compliance Electromagnetic Environment and Guidance

RF emissions

CISPR 11

Group 1 The equipment uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.

RF emissions

CISPR 11

Class B The equipment i s su i tab le for use in a l l establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.

Harmonic emissions

IEC 61000-3-2

Class A

Voltage fluctuations/

flicker emissions

IEC 61000-3-3

Complies

B.2  Electromagnetic ImmunityThe equipment is intended for use in the electromagnetic environment specified below. The customer or the user of the equipment should assure that it is used in such an environment.

Immunity Test IEC 60601 Test Level

Compliance Level

Electromagnetic Environment and Guidance

Electrostatic

d i s c h a r g e (ESD)

IEC 61000-4-2

±6 kV Contact

±8 kV Air

±6 kV Contact

±8 kV Air

Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%.

Page 153: About This Manual Statement - Creche Innovations

Appendix B EMC Guidance and Manufacturer’s Declaration

Basic User Manual 145

Immunity Test IEC 60601 Test Level

Compliance Level

Electromagnetic Environment and Guidance

Electrical fast

transient/burst

IEC 61000-4-4

±2 kV for power

supply lines;

±1 kV for input/

output lines

±2 kV for power

supply lines;

±1 kV for input/

output lines

Mains power quality should be that of a typical commercial or hospital environment.

Surge

IEC 61000-4-5

±1 kV l ine to line

±2 kV l ine to earth

±1 kV l ine to line

±2 kV l ine to earth

Mains power quality should be that of a typical commercial or hospital environment.

Vol tage d ips and

S h o r t interruptions

IEC 61000-4-11

<5 % UT

(>95 % dip in UT) for

0.5 period

40 % UT

(60 % dip in UT) for 5 periods

70 % UT

(30 % dip in UT) for 25 periods

<5 % UT

(>95 % dip in U T ) f o r 2 5 0 periods

<5 % UT

( > 9 5 % d i p in UT) for 0.5 period

40 % UT

(60 % dip in UT) for

5 periods

70 % UT

(30 % dip in UT) for

25 periods

<5 % UT

(>95 % dip in UT) for

250 periods

Mains power quality should be that of a typical commercial or hospital e n v i r o n m e n t . I f t h e u s e r o f t h e equipment requires continued operation during power mains interruptions, it is recommended for the equipment to be powered from an uninterrupted power supply.

P o w e r frequency

(50/60Hz)

magnetic field IEC 61000-4-8

3 A/m 3 A/m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment.

NOTE: UT is the AC mains voltage prior to application of the test level.

The equipment is intended for use in the electromagnetic environment specified below. The customer or the user of the equipment should assure that it is used in such an environment.

Page 154: About This Manual Statement - Creche Innovations

Appendix B EMC Guidance and Manufacturer’s Declaration

146 Basic User Manual

Immunity Test

IEC 60601Test Level

ComplianceLevel

Electromagnetic Environment and Guidance

Conducted RF

IEC 61000-4-6

3Vrms

1 5 0 k H z - 8 0 MHz

3 Vrms Portable and mobile RF communications equipment should be used no closer to any part of the EQUIPMENT, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.

Recommended separation distance:

80MHz-800 MHz

80 MHz-2.5GHz

Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey,a should be less than the compliance level in each frequency range. b Interference may occur in the vicinity of equipment marked with the following symbol:

R a d i a t e d R F IEC 61000-4-3

3V/m

8 0 M H z -2.5GHz

3 V/m

NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.

NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.

Page 155: About This Manual Statement - Creche Innovations

Appendix B EMC Guidance and Manufacturer’s Declaration

Basic User Manual 147

Immunity Test

IEC 60601Test Level

ComplianceLevel

Electromagnetic Environment and Guidance

a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the EQUIPMENT is used exceeds the applicable RF compliance level above, the EQUIPMENT should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the EQUIPMENT.b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.

B.3  Recommended Separation Distances between Portable and Mobile RF Communications Equipment and the Equipment

The equipment is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the equipment can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the equipment as recommended below, according to the maximum output power of the communications equipment.

Rated Maximum Output Power of Transmitter (W)

Separation distance according to frequency of transmitter (m)

150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2.5 GHz

0.01 0.12 0.12 0.23

0.1 0.38 0.38 0.73

1 1.2 1.2 2.3

10 3.8 3.8 7.3

100 12 12 23

For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.

NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.

NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.

Page 156: About This Manual Statement - Creche Innovations

148

Appendix  C  In Situ, Derated, and Water Value Intensities

All intensity parameters are measured in water. Since water absorbs very little acoustic energy, these water measurement represent a worst case value. Biological tissue does absorb acoustic energy. The true value of the intensity at any point depends on the amount and type of tissue and the frequency of the ultra-sound that passes through the tissue. The intensity value in the tissue, In Situ, has been estimated by using the following formula:

In Situ = Water[e-0:23alf]

where: In Situ = In Situ Intensity Value

Water = Water Value Intensity

e = 2.7183

a = Attenuation Factor

Tissue = a (dB/cm-MHz)

Amniotic Fluid = 0.006

Brain = 0.53

Heart = 0.66

Kidney = 0.79

Liver = 0.43

Muscle = 0.55

l = Skin line to measurement depth (cm)

f = Center frequency of the transducer/system/mode combination (MHz)

Since the ultrasonic path during an examination is likely to pass through varying lengths and types of tissue, it is difficult to estimate the true In Situ intensity. An attenuation factor of 0.3 is used for general reporting purposes; therefore, the In Situ value which is commonly reported uses the formula:

In Situ derated = Water[e-0.069lf]

Since this value is not the true In Situ intensity, the term “derated” is used.

Page 157: About This Manual Statement - Creche Innovations

149

Appendix  D  Recommended Coupling Gel, Cleaner and Disinfectant

NOTE:

• Coupling gels, cleaners and disinfectants listed in this manual are recommended because of their chemical compatibility with product materials, not their biological effectiveness. For the biological effectiveness of a disinfectant, refer to the guidelines and recommendations of the disinfectant manufacturer, Association for Practitioners in Infection Control, U.S. Food and Drug Administration, and U.S. Centers for Disease Control.

• This appendix contains the latest information about the recommended coupling gels, cleaners and disinfectants when the user manual is released. The appendix is subject to change without prior notice.

• Some of the probe models listed in the following tables can be used with this system. For details, refer to Section 10.1.1 Available Probes.

D.1 Coupling Gel

Probe Model Applicable Inapplicable

MPTEE Mini 7-4, MPTEE 7-4, MPTEE, MPTEE mini, 12C-ER

Aquasonic 100, Aquasonic Clear, Sterile Aquasonic, Clear Image/Single, Sterile Ultraphonic Gel

Transonic gel , Clear Scanning Gel, Multigel Gel

LAP7, C9-5, 10I2, 6CI-A, 6CT-A, 7LI4, 10I3, 10L-I, 12L-I, 12LI-A, 12LT-A, 11L-I

Aquasonic 100, Aquasonic Clear, Sterile Aquasonic, Clear Image/Single, Sterile Ultraphonic Gel, Transonic gel

Clear Scanning Gel, Multigel Gel

EC2, EC9-5, 5V1, 6V1, 6V3, 6V4, 6V5, BCC9-4, BCC9-5, BCL10-5, 6V-A, 6V1A, 6V2A, 6V3A, 6V7, 8V-A, 6CT4

Aquasonic 100, Aquasonic Clear, Sterile Aquasonic, Clear Image/Single, Sterile Ultraphonic Gel, Transonic gel, Clear Scanning Gel

Multigel Gel

VC6-2, VC8-3, VC311, VE9-5, VC6-2, VL12-5, CWD2.0, CWD4.0, CWD5.0, CWD8.0, PWD2.0

Aquasonic 100, Aquasonic Clear, Sterile Aquasonic, Clear Image/Single, Sterile Ultraphonic Gel, Transonic gel

Clear Scanning Gel, Multigel Gel

Page 158: About This Manual Statement - Creche Innovations

Appendix D Recommended Coupling Gel, Cleaner and Disinfectant

150 Basic User Manual

Probe Model Applicable Inapplicable

2P1, 5P1, 10L1, C311, C321, C343, C344, C351, C352, C361, C362, C511, C521, C541, C542, C543, C611, C612, C721, L541, L561V, L662V, L741, L741V, L742, L743, L745, L746, L751, L752, L761V, L744, C312, C322, C345, C353, C354, C544, C613, C5-1, 3C-A, C1-6, 2P2, 3P1, 3P-A, 4P-A, 4P-B, 5P2, 7P-A, 7P-B, 8P1, 12P-A, 12P-B, P5-1, 3C-B, 9L-A, 13L-A, 18L-A, LAP7, S1-5, 12L-A

Aquasonic 100, Aquasonic Clear, Sterile Aquasonic, Clear Image/Single, Sterile Ultraphonic Gel, Transonic gel, Clear Scanning Gel, Multigel Gel

/

D.2 Cleaner

Probe Model Applicable Inapplicable

MPTEE Mini 7-4, MPTEE 7-4, MPTEE, MPTEE mini, 12C-ER

Mild soapy water T-spray, T-spray II, Transeptic, 70% IPA

LAP7, C9-5, 10I2, 6CI-A, 6CT-A, 7LI4, 10I3, 10L-I, 12L-I, 12LI-A, 12LT-A, 11L-I

T-spray, T-spray II , mild soapy water

Transeptic, 70% IPA

EC2, EC9-5, 5V1, 6V1, 6V3, 6V4, 6V5, BCC9-4, BCC9-5, BCL10-5, 6V-A, 6V1A, 6V2A, 6V3A, 6V7, 8V-A, 6CT4

T-spray, T-spray II , mild soapy water

Transeptic, 70% IPA,

VC6-2, VC8-3, VC311, VE9-5, VC6-2, VL12-5, CWD2.0, CWD4.0, CWD5.0, CWD8.0, PWD2.0

T-spray, T-spray II , mild soapy water

Transeptic, 70% IPA

2P1, 5P1, 10L1, C311, C321, C343, C344, C351, C352, C361, C362, C511, C521, C541, C542, C543, C611, C612, C721, L541, L561V, L662V, L741, L741V, L742, L743, L745, L746, L751, L752, L761V, L744, C312, C322, C345, C353, C354, C544, C613, C5-1, 3C-A, C1-6, 2P2, 3P1, 3P-A, 4P-A, 4P-B, 5P2, 7P-A, 7P-B, 8P1, 12P-A, 12P-B, P5-1, 3C-B, 9L-A, 13L-A, 18L-A, LAP7, S1-5, 12L-A

T-spray, T-spray II , mild soapy water, 70% IPA

Transeptic

Page 159: About This Manual Statement - Creche Innovations

Appendix D Recommended Coupling Gel, Cleaner and Disinfectant

Basic User Manual 151

D.3 Disinfectant

Probe Model Applicable Inapplicable

MPTEE Mini 7-4, MPTEE 7-4, MPTEE, MPTEE mini, 12C-ER

C i d e x O P A Solution, Cidex, Metricide 14

Met r i c ide 28 , Me t r i c ide 30 , Resert XL HLD

LAP7, C9-5, 10I2, 6CI-A, 6CT-A, 7LI4, 10I3, 10L-I, 12L-I, 12LI-A, 12LT-A, 11L-I

C i d e x O P A Solution, Cidex, Metricide 14

Met r i c ide 28 , Me t r i c ide 30 , Resert XL HLD

EC2, EC9-5, 5V1, 6V1, 6V3, 6V4, 6V5, BCC9-4, BCC9-5, BCL10-5, 6V-A, 6V1A, 6V2A, 6V3A, 6V7, 8V-A, 6CT4

C i d e x O P A Solution, Cidex, M e t r i c i d e 1 4 , Resert XL HLD

Met r i c ide 28 , Metricide 30

VC6-2, VC8-3, VC311, VE9-5, VC6-2, VL12-5, CWD2.0, CWD4.0, CWD5.0, CWD8.0, PWD2.0

C i d e x O P A Solution, Cidex, Metricide 14

Me t r i c ide 28 , Me t r i c ide 30 , Resert XL HLD

2P1, 5P1, 10L1, C311, C321, C343, C344, C351, C352, C361, C362, C511, C521, C541, C542, C543, C611, C612, C721, L541, L561V, L662V, L741, L741V, L742, L743, L745, L746, L751, L752, L761V, L744, C312, C322, C345, C353, C354, C544, C613, C5-1, 3C-A, C1-6, 2P2, 3P1, 3P-A, 4P-A, 4P-B, 5P2, 7P-A, 7P-B, 8P1, 12P-A, 12P-B, P5-1, 3C-B, 9L-A, 13L-A, 18L-A, LAP7, S1-5, 12L-A

C i d e x O P A Solution, Cidex, M e t r i c i d e 1 4 , Resert XL HLD

Met r i c ide 28 , Metricide 30

Page 160: About This Manual Statement - Creche Innovations

152

Appendix  E  Acoustic Output Data

Please consult the accompanying CD.