ABB EMAX ACB

68
© ABB SACE - 1 SACE Emax LV Air Circuit Breaker – Range - Emax

description

ABB EMAX AIR CIRCUIT BREAKER

Transcript of ABB EMAX ACB

Page 1: ABB EMAX ACB

© A

BB

SA

CE

- 1

SACE Emax LV Air Circuit Breaker –

Range - Emax

Page 2: ABB EMAX ACB

© A

BB

SA

CE

- 2

SACE Emax

SACE EMAX:SACE EMAX:THE THIRD MILLENIUM IS IN THE AIRTHE THIRD MILLENIUM IS IN THE AIR

Page 3: ABB EMAX ACB

© A

BB

SA

CE

- 3

SACE Emax - History

1960 1970 1980 1990 1996

OTOMAX G30 NOVOMAX

MEGAMAX

EMAX

Page 4: ABB EMAX ACB

© A

BB

SA

CE

- 4

SACE Emax

The ABB SACE L.V. Quality System conforms to the International Standard ISO 9001

ISO 9001

ISO 14001

Page 5: ABB EMAX ACB

© A

BB

SA

CE

- 5

SACE Emax

Electrical characteristics

Technical and design characteristics

Microprocessor-based trip units

Terminals - Accessories - Versions

Applications

Page 6: ABB EMAX ACB

© A

BB

SA

CE

- 6

SACE Emax: Electrical characteristic

Currents (definitions)

Icu = RATED ULTIMATE SHORT CIRCUIT BREAKING CAPACITY

Ics = RATED SERVICE SHORT CIRCUITBREAKING CAPACITY

Icw = RATED SHORT-TIME WITHSTAND CURRENT

Page 7: ABB EMAX ACB

© A

BB

SA

CE

- 7

SACE Emax: Electrical characteristics

DIVERSIFIED BREAKING CAPACITIES RANGERATED ULTIMATE BREAKING CAPACITIES (Icu)

Selective circuit-breakers

B = BASE Icu = 40 kA

N = NORMAL Icu = 65 kA

S = STANDARD Icu = 75 kA

H = HIGH Icu = 100 kA

V = VERY HIGH Icu = 150 kA

Current-limiting circuit-breakers

L = CURRENT LIMITING Icu = 130 kA

E1N – 50 kA

Page 8: ABB EMAX ACB

© A

BB

SA

CE

- 8

SACE Emax: Electrical characteristics

Rated Voltage Ue = 690V a.c.

Rated uninterrupted current Iu = 800 - 6300 A

Rated ultimate breaking capacity Icu = 40-150kA

Rated insulation voltage Ui = 1000 V

Rated impulse withstand voltage Uimp = 12 kV

Frequency F = 50 - 60 Hz

Page 9: ABB EMAX ACB

© A

BB

SA

CE

- 9

Performance levels B N B N L N S H S H H V

[A] 800 800 1600 1000 1250 2500 1000 800 4000 3200 4000 3200[A] 1000 1000 2000 1250 1600 3200 1250 1000 4000 5000 4000[A] 1250 1250 1600 1600 1250 6300 5000[A] 1600 1600 2000 2000 1600 6300[A] 2500 2000[A] 3200 2500[A] 3200

Breaking capacityIcu @ 415 V AC [kA] 42 50 42 65 130 65 75 100 75 100 100 150Ics @ 415 V AC [kA] 42 50 42 65 130 65 75 85 75 100 100 125

Making capacity

Icm @ 415 V AC [kA] 88.2 105 88.2 143 286 143 165 220 165 220 220 330

Rated withstand currentIcw @ 1 s [kA] 42 50 42 55 10 65 75 75 75 100 100 100Icw @ 3 s [kA] 36 36 42 42 - 65 65 65 75 75 85 85

Utilisation category B B B B A B B B B B B B

Rated current Iu

E6E1 E2 E3 E4

SACE Emax: Electrical characteristics

Page 10: ABB EMAX ACB

© A

BB

SA

CE

- 1

0

FIXED

WITHDRAWABLE

VERSIONS

SACE Emax: Technical characteristics

TYPES

THREE - POLE

FOUR - POLE

50% and 100% rated up to 6300A

Page 11: ABB EMAX ACB

© A

BB

SA

CE

- 1

1

SACE Emax: Technical and design characteristics

Icw (1s) up to 75 kA with rate current In = 1250 - 1600 - 2000 - 2500 - 3200 A

Icw (1s) up to 100 kA with rated current In = 3200 - 4000 - 5000 - 6300 A

Icw (3s) up to 75 kA with rated current In = 1250-1600-2000-2500-3200-4000-5000-6300 A

A new construction concept for peak level

performance

Page 12: ABB EMAX ACB

© A

BB

SA

CE

- 1

2

SACE Emax: Technical characteristics

- Double the number of contact points

- No mechanical junctions in live parts

Reduced Contact Wear

Long Electrical Life

Page 13: ABB EMAX ACB

© A

BB

SA

CE

- 1

3

SACE Emax: Technical characteristics

- Single pole construction concept

Page 14: ABB EMAX ACB

© A

BB

SA

CE

- 1

4

SACE Emax: Technical characteristics

- Metal supporting structure

- Double insulation between auxiliary circuits and power circuits

- Pre-wired electrical accessories connected from the front of the breaker

Page 15: ABB EMAX ACB

© A

BB

SA

CE

- 1

5

SACE Emax: Technical characteristics

- Breaking chamber visible for inspection

- Simplified changing of current transformer set

Page 16: ABB EMAX ACB

© A

BB

SA

CE

- 1

6

SACE Emax: Technical characteristics

Completeness of range

800A

6300A

Page 17: ABB EMAX ACB

© A

BB

SA

CE

- 1

7

SACE Emax: Technical characteristics

- Reduced volumes

- Only 4 mounting points

Building of compact switchboards

Page 18: ABB EMAX ACB

© A

BB

SA

CE

- 1

8

SACE Emax: Technical characteristics

Sheet steel supporting structure

Earthing contacts (one for E1, E2, E3,

two for E4, E6)

Safety shutters (Protection class IP20)

Isolating base for the terminals

Terminals (RH, RV,F)

Auxiliary contacts (conn/test/disconn)

Sliding contacts

Fixing points (4 for E1,2,3 and 6 for

E4,6)

1

2

3

4

5

6

7

8

7

2

8

3

4

5

6

1

Page 19: ABB EMAX ACB

© A

BB

SA

CE

- 1

9

SACE Emax: Technical characteristics

Page 20: ABB EMAX ACB

© A

BB

SA

CE

- 2

0

SACE Emax: Overcurrent releases

New generation of microprocessor-based overcurrent releases

Page 21: ABB EMAX ACB

© A

BB

SA

CE

- 2

1

SACE Emax: Overcurrent releases

Three versions available for the entire series

Complete range of protection functions (L, S, I, G)

Complete range of protection functions + Accessory functions

PR111PR111

PR112PR112

Complete range of protection functions + Accessory functionsPR113PR113

Page 22: ABB EMAX ACB

© A

BB

SA

CE

- 2

2

SACE Emax: Overcurrent releases

Available functions:

Protection (L, S, I, G)

Self - protection

Test

Load control

Page 23: ABB EMAX ACB

© A

BB

SA

CE

- 2

3

Available functions:

SACE Emax: Overcurrent releases

Self - control (Watchdog System)

Alarms

Measurements

Controlling and monitoring

Page 24: ABB EMAX ACB

© A

BB

SA

CE

- 2

4

SACE Emax: Overcurrent releases

Selectivity for all installation needs

Self-powered unit for protection function only

Interchangeability

Page 25: ABB EMAX ACB

© A

BB

SA

CE

- 2

5

SACE Emax: Overcurrent releases

COMPLETE RANGE OF PROTECTION FUNCTIONS (L, S, I, G)

VERSIONS AVAILABLE : - PR111/ L I- PR111/ L S I- PR111/ L S I G

SELF SUPPLIED DEVICE

POSSIBILITY TO TEST THE TRIP UNIT WITH EXTERNAL DEVICE

AVAILABLE IEC AND UL LISTED

PR111PR111

Page 26: ABB EMAX ACB

© A

BB

SA

CE

- 2

6

SACE Emax: Overcurrent releases

1

7

6 3

2 13

12

8

4

5

15 16

20

11

9

10

18 17

19

1 6 7

SACE PR111/P OVERCURRENT RELEASE

Page 27: ABB EMAX ACB

© A

BB

SA

CE

- 2

7

SACE Emax: Overcurrent releases

SACE PR111/P OVERCURRENT RELEASE

Thresholds and tripping times

FUNCTIONCurrent

thresholdsteps Tripping time Curves Cut-out relation t = f(I)

L I1 =0,4 1In 8 t1=3 18s (6xI1) 4 no t = k/I2

S I2 =1 10In 7 t2=0,05 0,5s (8xI2) 4 yes t = k/I2 e t = k

I I3 =1,5 12In 7 instantaneous - yes t = k

G I4 =0,4 1In 7 t3=0,1 0,8s 4 yes t = k/I2

Page 28: ABB EMAX ACB

© A

BB

SA

CE

- 2

8

COMPLETE RANGE OF PROTECTION FUNCTIONS (L, S, I, G)

VERSIONS AVAILABLE: - PR112/P L S I

- PR112/P L S I G

- PR112/PD L S I LON Protocol

- PR112/PD L S I G LON Protocol

- PR112/PD LSI ModBus RTU Protocol

- PR112/PD LSIG ModBus RTU Protocol

PR112PR112

SACE Emax: Overcurrent releases

Page 29: ABB EMAX ACB

© A

BB

SA

CE

- 2

9

SACE Emax: Overcurrent releases

MEASUREMENT FUNCTIONS: ammeter, contact wear, n° operations

SELF-POWERED DEVICE

SELF-PROTECTION AGAINST OVERTEMPERATURE

CONTROLLING AND MONITORING

MICROPROCESSOR SELF-DIAGNOSIS (WATCHDOG)

CERTIFICATED BY RINA, DNV,BV,GL,ABS

5 LANGUAGES DISPLAY

NEUTRAL SETTING BY DISPLAY

LOAD CONTROL AVAILABLE BY PR010/K

CONTACT K51/pl CONFIGURABLE

PR112PR112

Page 30: ABB EMAX ACB

© A

BB

SA

CE

- 3

0

SACE Emax: Overcurrent releases

SACE PR112/P AND PR112/PD OVERCURRENT RELEASES

9 10 11 12 1313

14

16 5 4 37 2

Page 31: ABB EMAX ACB

© A

BB

SA

CE

- 3

1

SACE Emax: Overcurrent releases

SACE PR112 OVERCURRENT RELEASE

Thresholds and tripping times

FUNCTION steps relation t = f(I)

L I1 =0,4 1In 0,01 t1=3 144s (3xI1) 3s no t = k/I2

S I2 =0,6 10 In 0,1 t2=00,75s (10xI2) 0,01s yes t = k/I2 e t = k

I I3 =1,5 15In 0,1 instantaneous - yes t = k

G I4 = 0,2 1In 0,02 t3=0,1 1s 0,05s yes t = k/I2 e t = k

Currentthreshold

Tripping time Steps Cut-out

Page 32: ABB EMAX ACB

© A

BB

SA

CE

- 3

2

VERSIONS AVAILABLE:

- PR113/P L S I G

- PR113/PD - M L S I G Modbus RTU

COMMUNICATION LINE

- RS485 with other Protocols

PR113 with LON protocol will available in future

PR113PR113

SACE Emax: Overcurrent releases

Page 33: ABB EMAX ACB

© A

BB

SA

CE

- 3

3

STANDARD RANGE OF PROTECTION FUNCTIONS (L, S, I, G)

(More current and time setting steps in functions)

NEW PROTECTIONS AVAILABLE:

V Minimum / Maximum / Residual voltage

F Unbalanced phase

P Inverse power flow

D Directional

NEUTRAL SETTINGNEUTRAL SETTING: 50% - 100% - 150% - 200%

PR113PR113

Protections

SACE Emax: Overcurrent releases

Page 34: ABB EMAX ACB

© A

BB

SA

CE

- 3

4

SACE PR113/P AND PR113/PD OVERCURRENT RELEASES

10 11

1

16

6 5 4

9

238 7

12 13 14 15

17

SACE Emax: Overcurrent releases

Page 35: ABB EMAX ACB

© A

BB

SA

CE

- 3

5

Ammeter

Voltages

Power (P - Q - A)

Harmonic distortion (20th)

PR113PR113

Measurements

Contact wear

N° Operations

Energy

5 Languages Graphic Display5 Languages Graphic Display NEW !!!

SACE Emax: Overcurrent releases

Page 36: ABB EMAX ACB

© A

BB

SA

CE

- 3

6

PR113PR113

Measurements

Page 37: ABB EMAX ACB

© A

BB

SA

CE

- 3

7

SACE Emax: Overcurrent releases

SACE PR111 & PR112 accessories

- SACE PR010/T Test Unit

- SACE PR010/K Signaling unit

- PR110/B Battery unit

Page 38: ABB EMAX ACB

© A

BB

SA

CE

- 3

8

SACE Emax: Overcurrent releases

SACE PR112 accessory unitSACE PR010/T

PROTECTION FUNCTION TESTING

TRIP TEST

PROGRAMMING FUNCTION

READING PARAMETERS FUNCTION

Page 39: ABB EMAX ACB

© A

BB

SA

CE

- 3

9

SACE Emax: Overcurrent releases

SACE PR112 accessory unitSACE PR010/K

EXTERNAL SIGNALING UNIT

- overload alarm function L- protection L tripped

- protection S tripped - protection I tripped - protection G tripped

- overtemperature (T=85°C)

LOAD CONTROL

- disconnection of two different loads- disconnection/connection of the same load

Page 40: ABB EMAX ACB

© A

BB

SA

CE

- 4

0

SACE Emax: Automatic Transfer Switch

Page 41: ABB EMAX ACB

© A

BB

SA

CE

- 4

1

What is ATS010:

• Automatic transfer switch device

• Microprocessor based

• All series of circuit-breakers

(Isomax, Tmax, Emax)

ATSG

1 2

LOAD

SACE Emax: Automatic Transfer Switch

Page 42: ABB EMAX ACB

© A

BB

SA

CE

- 4

2

SACE Emax: Terminals

Complete series of terminals

Modular design

Transformation kits available

Page 43: ABB EMAX ACB

© A

BB

SA

CE

- 4

3

SACE Emax: Terminals

Fixed version

Withdrawable version

Page 44: ABB EMAX ACB

© A

BB

SA

CE

- 4

4

SACE Emax: Accessories

A single range of accessories for the entire series

Page 45: ABB EMAX ACB

© A

BB

SA

CE

- 4

5

SACE Emax: Electrical accessories

Shunt Opening, Shunt Closing, Undervoltage releases

Circuit-breakers SOR Total

F1 - F2a.c.

MEGAMAXd.c.

F3 - F6a.c.

d.c.

EMAX E1 - E6 a.c./d.c.

12

2

SCR UVR

Page 46: ABB EMAX ACB

© A

BB

SA

CE

- 4

6

SACE Emax: Electrical accessories

- Opening/Closing release unified (YO/YC)

- Undervoltage release (YU)

Page 47: ABB EMAX ACB

© A

BB

SA

CE

- 4

7

SACE Emax: Electrical accessories

Shunt closing release (YC)

Undervoltage release (UVR)

Shunt closing release (YO)

Auxiliary releases

Page 48: ABB EMAX ACB

© A

BB

SA

CE

- 4

8

SACE Emax: Electrical accessories

- Time-delay device forundervoltage release

- SACE SOR Test Unit

Page 49: ABB EMAX ACB

© A

BB

SA

CE

- 4

9

SACE Emax: Electrical accessories

- Motor operator for automatic loading of closing springs

- Mechanical indication of Overcurrent release tripped

Page 50: ABB EMAX ACB

© A

BB

SA

CE

- 5

0

SACE Emax: Electrical accessories

Motor operator for automatic loadingof closing springs

Page 51: ABB EMAX ACB

© A

BB

SA

CE

- 5

1

SACE Emax: Electrical accessories

- Electrical indication of overcurrent release tripped

- Electrical signalling of circuit-breaker open/closed

Page 52: ABB EMAX ACB

© A

BB

SA

CE

- 5

2

SACE Emax: Electrical accessories

- Electrical signaling of circuit-breaker connected/test/disconnected position

- Contact for signaling closing springs loaded

Page 53: ABB EMAX ACB

© A

BB

SA

CE

- 5

3

SACE Emax: Electrical accessories

- Current transformer for external neutral

- External toroid for transformer star-centre (Source Ground Return)

Page 54: ABB EMAX ACB

© A

BB

SA

CE

- 5

4

SACE Emax: Mechanical accessories

- Operation counter

- Lock in open position (padlock or key lock devices)

Page 55: ABB EMAX ACB

© A

BB

SA

CE

- 5

5

SACE Emax: Mechanical accessories

- Lock in connected / test / disconnected position (padlock and key lock devices)

- Accessory for lock in disconnected /disconnected for test position

Page 56: ABB EMAX ACB

© A

BB

SA

CE

- 5

6

SACE Emax: Mechanical accessories

- Mechanical lock for compartment door

- Padlock device for safety shutters

Page 57: ABB EMAX ACB

© A

BB

SA

CE

- 5

7

SACE Emax: Mechanical accessories

- IP54 protective cover for door

- Protection for opening and closing push-buttons

Page 58: ABB EMAX ACB

© A

BB

SA

CE

- 5

8

SACE Emax: Electrical accessories

Current transformer set

Page 59: ABB EMAX ACB

© A

BB

SA

CE

- 5

9

SACE Emax: Mechanical accessories

Mechanical interlocks kits

Page 60: ABB EMAX ACB

© A

BB

SA

CE

- 6

0

SACE Emax: Mechanical accessories

1 2

1 2 3

G

1 32

G

1 2

Type A

Type B

Type C

Type D

O =Open Circuit-Breaker - I = Closed Circuit-Breaker

1 2 31 2 3

1 32

G

1 32

Page 61: ABB EMAX ACB

© A

BB

SA

CE

- 6

1

SACE Emax: Derived versions

• Switch-disconnector

• Isolating truck

• Earthing switch with making capacity

• Earthing truck

MS

CS

MTP

MT

MTCS MTP

Page 62: ABB EMAX ACB

© A

BB

SA

CE

- 6

2

SACE Emax: Special versions

For aggressive ambience (SO2)

For anti-seismic installations

For Navy

1000 V A.C.

1000 V D.C. (Switch disconnector only)

Page 63: ABB EMAX ACB

© A

BB

SA

CE

- 6

3

Special versionEMAX / E Ue=1000 V a.c.

SACE Emax: Special versions

E2B/E E2N/E E3H/E E4H/E

Iu [A] 1600 2000 1250 1600 2000 1250 1600 2000 2500 3200 3200 4000

Ue [V] 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

Icu [kA] 20 20 30 30 30 50 50 50 50 50 65 65

Ics [kA] 20 20 30 30 30 50 50 50 50 50 65 65

Icw [kA] 20 20 30 30 30 50 50 50 50 50 65 65

Page 64: ABB EMAX ACB

© A

BB

SA

CE

- 6

4

SACE Emax: “RETROFITTING”

Kits for simplified replacement of oldcircuit-breakers in the following series

SACE OtomaxSACE Novomax G30

With SACE Emax circuit-breakers

Page 65: ABB EMAX ACB

© A

BB

SA

CE

- 6

5

SACE Emax: Applications

POWER CENTER

Page 66: ABB EMAX ACB

© A

BB

SA

CE

- 6

6

SACE Emax: Applications

Generator/Motor protection

Transformer protection

Capacitor protection

Switching sets

Marine plants

Page 67: ABB EMAX ACB

© A

BB

SA

CE

- 6

7

SACE Emax: Applications

Automated installations

Installations characterized by high short circuit currents

Installations with special selectivity needs

Use in polluted environments

Page 68: ABB EMAX ACB

© A

BB

SA

CE

- 6

8

SACE Emax

SACE EMAX:SACE EMAX:THE THIRD MILLENIUMTHE THIRD MILLENIUM

IS IN THE AIRIS IN THE AIR