  • Features

    Application

    Standards Engineering InformationClass AA stranding are used for overhead transmission lines.

    Class A stranding are primary used in covered overhead lines. Greater flexibility than Class AA.

    ASTM B-231Concentric-Lay-stranded Aluminum 1350 Conductors

    ASTM B-230Specification for Aluminum-1350-H19 Wire for Electrical purposes

    Conductor: Aluminum alloy 1350-H19 wires.

    Stranding: 1350-H19 aluminum wires concentrically stranded, consisting of one or more layers of wires helically wrapped around a central wire.

    Use as bare overhead transmission cable, and as a primary and secondary distribution cable, where a lighter conductor is desired, vs. an ACSR conductor, and conductor strength is not an important factor

    Type AAC All Aluminum Conductor

    7.1

    www.cmewire.com

    Copyright 2006 CME Wire and Cable, Inc. All Rights Reserved. For more information feel free to contact us. 495 Horizon Drive NE, Suite 100, Suwanee, Georgia 30024 Phone: 770.623.0001 Fax: 678.546.5729

  • Type AAC All Aluminum Conductor

    AAC - All Aluminum ConductorsSize Cross

    Code AWG Number Stranding Individual Complete Section Net Rated dc ac 75CWord or of Class Wires Cable Area Weight Strength 20C 75C Ampacity

    kcmil Strands inches inches Sq. Inches Lbs/Mft lbs OHMS/Mile OHMS/MileROSE 4 7 A 0,0772 0,23 0,0328 39 881 2,1880 2,6740 140IRIS 2 7 AA, A 0,0974 0,29 0,0522 62 1350 1,3740 1,6800 185

    PANSY 1 7 AA, A 0,1093 0,33 0,0657 78 1640 1,0910 1,3340 215POPPY 1/0 7 AA, A 0,1228 0,37 0,0829 99 1990 0,8646 1,0570 245ASTER 2/0 7 AA, A 0,1379 0,41 0,1045 125 2510 0,6856 0,8380 285PHLOX 3/0 7 AA, A 0,1548 0,46 0,1317 157 3040 0,5441 0,6650 330OXLIP 4/0 7 AA, A 0,1739 0,52 0,1663 198 3830 0,4311 0,5280 380DAISY 266,8 7 AA 0,1952 0,59 0,2095 250 4830 0,3418 0,4190 440

    LAUREL 266,8 19 A 0,1185 0,59 0,2095 250 4970 0,3421 0,4190 445TULIP 336,4 19 A 0,1331 0,67 0,2644 315 6150 0,2711 0,3320 515

    CANNA 397,5 19 AA, A 0,1446 0,72 0,3120 373 7110 0,2294 0,2820 570COSMOS 477 19 AA 0,1584 0,79 0,3744 447 8360 0,1914 0,2350 640

    ZINNIA 500 19 AA 0,1622 0,81 0,3926 469 8760 0,1826 0,2250 655DAHLIA 556,5 19 AA 0,1711 0,86 0,4369 522 9750 0,1641 0,2020 705ORCHID 636 37 AA, A 0,1311 0,92 0,4995 596 11400 0,1435 0,1770 765VIOLET 715,5 37 AA 0,1391 0,97 0,5623 671 12800 0,1275 0,1580 820

    PETUNIA 750 37 AA 0,1424 1,00 0,5893 703 13100 0,1216 0,1510 845ARBUTUS 795 37 AA 0,1466 1,03 0,6245 745 13900 0,1148 0,1420 880MAGNOLIA 954 37 AA 0,1606 1,12 0,7495 894 16400 0,0956 0,1200 980BLUEBELL 1033,5 37 AA 0,1671 1,17 0,8114 969 17700 0,0882 0,1110 1030MARIGOLD 1113 61 AA, A 0,1351 1,22 0,8744 1043 19700 0,0820 0,1030 1080HAWTHORN 1192,5 61 AA, A 0,1398 1,26 0,9363 1118 21100 0,0766 0,0968 1125NARCISSUS 1272 61 AA, A 0,1444 1,30 0,9990 1192 22000 0,0718 0,0911 1170COLUMBINE 1351,5 61 AA, A 0,1488 1,34 1,0608 1267 23400 0,0675 0,0861 1210CARNATION 1431 61 AA, A 0,1532 1,38 1,1244 1341 24300 0,0638 0,0817 1255GLADIOLUS 1510,5 61 AA, A 0,1574 1,42 1,1869 1416 25600 0,0604 0,0778 1295COREOPSIS 1590 61 AA 0,1614 1,45 1,2480 1490 27000 0,0674 0,0743 1330JESSAMINE 1750 61 AA 0,1694 1,52 1,3748 1640 29700 0,0521 0,0683 1405COWSLIP 2000 91 A 0,1482 1,63 1,5697 1875 34200 0,0457 0,0609 1515

    The above data are approximate and subject to normal manufacturing tolerances.Direct current resistance is based on 16.946 ohm-cmil/ft at 20C for 1350 aluminum nominal area of conductor with standard stranding increments ASTM B 231Alternating current (ac) Resistance is based on dc Resistance corrected for temperature using 0.00404 as temeprature coefficient of resistivity per degres C at 20C and skin effect Ampacities are based on the following: Conductivity 61.2%, Air Ambient 25C, Wind 2 ft/s, Sun, Sea level , Solar Absorption 0.5, Emissivity 0.5Reference: " Ampacities for Aluminum and ACSR overhead electrical conductors , The Aluminum Association, Inc,1986 "

    Diameter Resistance