AAA Stent Graft System · 2019. 1. 18. · The Anaconda™ AAA Stent Graft System: 2-Year Clinical...

4
The world’s FIRST repositionable stent graft Patented magnet cannulation system NEW ONE-LOK™ BODY Additional ring stents designed to maximise lumen diameter and blood flow Common distal lumen docking zone diameter AAA Stent Graft System

Transcript of AAA Stent Graft System · 2019. 1. 18. · The Anaconda™ AAA Stent Graft System: 2-Year Clinical...

  • The world’s FIRSTrepositionable

    stent graft

    Patented magnet cannulation system

    NEW ONE-LOK™ BODYAdditional ring stents

    designed to maximise lumen diameter and

    blood flow

    Common distal lumen docking zone diameter

    AAA Stent Graft System

  • introducer sheathThe hydrophilic coating enhances the passage of the

    delivery sheath through the arteries 2

    REPOSITIONABILITY• The world’s first repositionable stent graft system

    • Enables accurate infrarenal placement of the stent graftproximal ring stents 1

    PATENTEDmagnet cannulation system

    Significantly reduces the cannulation time of thebifurcate body contralateral limb compared

    with standard cannulation techniques 1

    • Deployed • Re-deployed• Collapsed

    AAA Stent Graft System

  • NEW ONE-LOK™ BODYadditional body ring stents

    designed to • Maximise lumen diameter and

    blood flow 5

    • Provide an open lumen for ipsilateral leg cannulation 5

    NEW ONE-LOK™ BODYcommon distal lumen

    docking zone diameter• Ease of device selection 6

    • Optimal body: leg combinations 6

    SECUREThe dual proximal ring stent design with hooks provides excellent sealing function with positive fixation 2,3,4

    FLEXIBILITYThe multiple independent leg ring stent design

    • Provides maximum flexibility to cater for varying patient anatomies 4

    • Minimises the potential for kinking 1, 3

  • AAA Stent Graft System

    Product Ordering Information

    B I F U R C A T E B O D I E SCATALOGUE DEVICEOUTErDIAmETEr COmpATIbLEAOrTICVESSEL SYSTEmDELIVErYSHEATHNUmbEr A(mm) INTErNALDIAmETErrANGE(mm) OUTErDIAmETEr(Fr)

    OLB21 21.5 17.5 - 19.5 20OLB23 23.5 19.5 - 21.0 20OLB25 25.5 21.0 - 23.0 23OLB28 28.0 23.0 - 25.0 23OLB30 30.5 25.0 - 27.5 23OLB32 32.0 26.5 - 29.0 23OLB34 34.0 28.5 - 31.0 23

    S T R A I G H T L E G SCATALOGUE OUTErDIAmETEr LENGTH COmpATIbLEDISTALILIACVESSEL SYSTEmDELIVErYSHEATHNUmbEr A(mm) L(mm) INTErNALDIAmETErrANGE(mm) OUTErDIAmETEr(Fr)

    L12X060 12 60 10.0 - 11.5 18L12X080 12 80 10.0 - 11.5 18L12X100 12 100 10.0 - 11.5 18L12X120 12 120 10.0 - 11.5 18L12X140 12 140 10.0 - 11.5 18

    T A P E R E D L E G SCATALOGUE OUTErDIAmETEr LENGTH COmpATIbLEDISTALILIACVESSEL SYSTEmDELIVErYSHEATHNUmbEr proximal Distal L(mm) INTErNALDIAmETErrANGE(mm) OUTErDIAmETEr(Fr) A(mm) b(mm)

    TL1210X080 12 10 80 8.5 - 9.5 18TL1210X110 12 10 110 8.5 - 9.5 18TL1210X130 12 10 130 8.5 - 9.5 18

    F L A R E D L E G SCATALOGUE OUTErDIAmETEr LENGTH COmpATIbLEDISTALILIACVESSEL SYSTEmDELIVErYSHEATHNUmbEr proximal Distal L(mm) INTErNALDIAmETErrANGE(mm) OUTErDIAmETEr(Fr) A(mm) b(mm)

    FL1213X080 12 13 80 11.0 - 12.5 18FL1213X110 12 13 110 11.0 - 12.5 18FL1213X130 12 13 130 11.0 - 12.5 18FL1215X080 12 15 80 12.5 - 14.0 18FL1215X110 12 15 110 12.5 - 14.0 18FL1215X130 12 15 130 12.5 - 14.0 18FL1217X080 12 17 80 13.5 - 15.0 18FL1217X110 12 17 110 13.5 - 15.0 18FL1217X130 12 17 130 13.5 - 15.0 18FL1219X085 12 19 85 15.5 - 17.0 18FL1219X110 12 19 110 15.5 - 17.0 18FL1219X130 12 19 130 15.5 - 17.0 18FL1221X085 12 21 85 16.5 - 19.0 18FL1221X110 12 21 110 16.5 - 19.0 18FL1221X130 12 21 130 16.5 - 19.0 18FL1223X090 12 23 90 18.5 - 21.0 18FL1223X110 12 23 110 18.5 - 21.0 18FL1223X130 12 23 130 18.5 - 21.0 18

    VASCUTEK, a TErUmO CompanyNewmains Avenue, Inchinnan

    Renfrewshire PA4 9RR Scotland, UK Tel: (+44) 141 812 5555 Fax: (+44) 141 812 7170

    www.vascutek.com

    B298/1E

    References1. Rodel S, Geelkerken R, Prescott R, Florek H, Kasprzak P and Brunkwall J. The Anaconda™ AAA Stent Graft

    System: 2-Year Clinical and Technical Results of a Multicentre Clinical Evaluation Eur J Vasc Endovasc Surg 38, 732-740 (2009).

    2. Supporting Clinical Data on file at Vascutek.3. Stella A, Freyrie A, Gargiulo M and Faggioli G. The Advantages of the Anaconda™ for AAA J Cardiovasc Surg

    2009;50:145-1524. Freyrie A, Testi G, Faggioli G, Gargiulo M, Giovanetti F, Serra C and Stella A. Ring-Stents Supported

    Infrarenal Aortic Endograft Fits Well in Abdominal Aortic Aneurysms with Tortuous Anatomy J Cardiovasc Surg 2010;51(4):467-474

    5. Data on file.6. ONE-LOKTM Sizing Chart.

    , ONE-LOKTM and are trademarks of Vascutek Ltd

    Patent No. US 6,264,662 Products available subject to local regulatory approval.OO86

    A

    A

    B

    A

    L

    L

    L

    A

    B

    A comprehensive range of aortic extension cuffs is also available.