A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010
description
Transcript of A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010
![Page 1: A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010](https://reader035.fdocuments.net/reader035/viewer/2022062501/56815f60550346895dce4702/html5/thumbnails/1.jpg)
®
A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR
EWEC 2010
![Page 2: A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010](https://reader035.fdocuments.net/reader035/viewer/2022062501/56815f60550346895dce4702/html5/thumbnails/2.jpg)
®2
Overview
1. Pseudo direct drive PDD®
2. Wind generator development
3. Benefits for wind energy
![Page 3: A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010](https://reader035.fdocuments.net/reader035/viewer/2022062501/56815f60550346895dce4702/html5/thumbnails/3.jpg)
®3
Magnetic gearing&
PDD®
![Page 4: A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010](https://reader035.fdocuments.net/reader035/viewer/2022062501/56815f60550346895dce4702/html5/thumbnails/4.jpg)
®4
Video presentation
![Page 5: A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010](https://reader035.fdocuments.net/reader035/viewer/2022062501/56815f60550346895dce4702/html5/thumbnails/5.jpg)
®5
• Three components• Two are free to rotate, the third is mechanically earthed
High torque magnetic gear
![Page 6: A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010](https://reader035.fdocuments.net/reader035/viewer/2022062501/56815f60550346895dce4702/html5/thumbnails/6.jpg)
®6
0
0.1
0.2
0.3
0.4
0.5
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29
Harmonic number
Nor
mal
flux
den
sity
(T
)
-0.4-0.3-0.2-0.10.00.10.20.30.4
0 100 200 300
Angular position (degrees)
Nor
mal
flux
den
sity
(T)
Field of inner magnets without pole-pieces
4 pole-pair spatial harmonic (fundamental)
![Page 7: A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010](https://reader035.fdocuments.net/reader035/viewer/2022062501/56815f60550346895dce4702/html5/thumbnails/7.jpg)
®7
-0.7-0.5-0.3-0.10.10.30.50.7
0 100 200 300
Angular position (degrees)
Nor
mal
flux
den
sity
(T)
0
0.1
0.2
0.3
0.4
0.5
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29
Harmonic number
Nor
mal
flux
den
sity
(T
)
Harmonic at 27-4=23
Field of inner magnets with pole-pieces
Original 4 pole-pair fundamental
![Page 8: A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010](https://reader035.fdocuments.net/reader035/viewer/2022062501/56815f60550346895dce4702/html5/thumbnails/8.jpg)
®8
No pole-pieces
![Page 9: A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010](https://reader035.fdocuments.net/reader035/viewer/2022062501/56815f60550346895dce4702/html5/thumbnails/9.jpg)
®9
With pole-pieces
![Page 10: A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010](https://reader035.fdocuments.net/reader035/viewer/2022062501/56815f60550346895dce4702/html5/thumbnails/10.jpg)
®10
• Improved reliability • Improved efficiency• Reduced maintenance • No gear wear • Lighter for large torques• Inherent overload protection• Unlikely to jam• Reduced noise/vibration
Magnetic gear benefits
![Page 11: A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010](https://reader035.fdocuments.net/reader035/viewer/2022062501/56815f60550346895dce4702/html5/thumbnails/11.jpg)
®11
A combination of two magnetic transmissions
![Page 12: A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010](https://reader035.fdocuments.net/reader035/viewer/2022062501/56815f60550346895dce4702/html5/thumbnails/12.jpg)
®12
• Highest torque-density electrical machine• Removes gearbox• Overload protection• Very high efficiency• Requires little or no cooling• High power factor• Standard power electronic control
PDD® benefits
![Page 13: A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010](https://reader035.fdocuments.net/reader035/viewer/2022062501/56815f60550346895dce4702/html5/thumbnails/13.jpg)
®13
3MW wind turbine PDD® generator
![Page 14: A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010](https://reader035.fdocuments.net/reader035/viewer/2022062501/56815f60550346895dce4702/html5/thumbnails/14.jpg)
®14
3MW PDD®
• 3.8m diameter • 1.8m length • 40T mass
![Page 15: A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010](https://reader035.fdocuments.net/reader035/viewer/2022062501/56815f60550346895dce4702/html5/thumbnails/15.jpg)
®15
Advanced DD PMG 3MW5m OD 2.5m length75 tonnes
Geared DFIG 3MW Magnomatics PDD 3.8m OD 1.8 length40 tonnes.
Size reduction
![Page 16: A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010](https://reader035.fdocuments.net/reader035/viewer/2022062501/56815f60550346895dce4702/html5/thumbnails/16.jpg)
®16
Annual energy output
Taken from Garrad Hassan study
![Page 17: A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010](https://reader035.fdocuments.net/reader035/viewer/2022062501/56815f60550346895dce4702/html5/thumbnails/17.jpg)
®17
Benefits for wind energy
• Removes gearbox -> increases turbine reliability
• High efficiency
• Light weight
• Low maintenance
• Torque fuse protects drivetrain
• Scalable for larger WTs
![Page 18: A MAGNETICALLY-GEARED COMPACT 3MW DIRECT DRIVE GENERATOR EWEC 2010](https://reader035.fdocuments.net/reader035/viewer/2022062501/56815f60550346895dce4702/html5/thumbnails/18.jpg)
®18
Next steps
• Design, build and test 500kW demonstrator
• Evaluate technical and economic benefit
• Develop 3MW generator
• Test on turbine
• Certification and production engineering
• Develop 6-7MW generator for offshore