A Guide To Using > WinCAPS 2008 Grundfos International Version

Transcript of A Guide To Using WinCAPS 2008 -...

Page 1: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

A Guide To Using

> WinCAPS 2008

Grundfos International Version

Page 2: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Introduction.............................................................................................................................................. 4 General ............................................................................................................................................ 4 Who should use this program? .................................................................................................... 4 Disclaimer ........................................................................................................................................ 5

What's new .............................................................................................................................................. 6 New Products.................................................................................................................................. 6 New functionality Version 2008.................................................................................................... 6 New Functionality Version 7.9...................................................................................................... 7 New Functionality Version 7.8...................................................................................................... 8 New Functionality Version 7.6...................................................................................................... 9

WinCAPS Online user training ........................................................................................................... 13 General .......................................................................................................................................... 13

Internet Updates (WinCAPS only) ..................................................................................................... 14 General .......................................................................................................................................... 14

Installing WinCAPS .............................................................................................................................. 15 General .......................................................................................................................................... 15 Uninstalling WinCAPS ................................................................................................................. 16 Problems with Installation ........................................................................................................... 17 Network installation, guidelines for system administrators .................................................... 17 Client Server Installation on Local Network (Graphical Instruction)..................................... 19

Starting WinCAPS for the first time, Setting the Options Menu .................................................... 22 General .......................................................................................................................................... 22 Setting the tabs ............................................................................................................................. 22

Getting started with CAPS .................................................................................................................. 24 CAPS, a quick tour ....................................................................................................................... 24 How CAPS is built up................................................................................................................... 24 Layout of the screen .................................................................................................................... 25 The File Menu (WinCAPS only) ................................................................................................. 25

Catalogue .............................................................................................................................................. 28 General .......................................................................................................................................... 28 Viewing the pump curve in the catalogue area, extensive possibilities............................... 30 Operating point tab....................................................................................................................... 31 Hydraulic layout tab ..................................................................................................................... 31 Fluid tab ......................................................................................................................................... 32 Curve types tab............................................................................................................................. 33 Other Curves tab .......................................................................................................................... 34

Sizing - Heating .................................................................................................................................... 36 Getting started with Sizing .......................................................................................................... 36 The Sizing Wizard, a quick tour ................................................................................................. 36 Heating ........................................................................................................................................... 37

Sizing - Air Conditioning ...................................................................................................................... 45 Getting started with Sizing .......................................................................................................... 45 The Sizing Wizard, a quick tour ................................................................................................. 45 Air-Conditioning ............................................................................................................................ 46

Page 3: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Sizing - Groundwater Supply.............................................................................................................. 53 Getting started with Sizing .......................................................................................................... 53 The Sizing Wizard, a quick tour ................................................................................................. 53 Groundwater ................................................................................................................................. 54

Sizing - Domestic Water Supply ........................................................................................................ 60 Getting started with Sizing .......................................................................................................... 60 The Sizing Wizard, a quick tour ................................................................................................. 60 Domestic Water Supply ............................................................................................................... 61

Sizing - Wastewater ............................................................................................................................. 66 Getting started with Sizing .......................................................................................................... 66 The Sizing Wizard, a quick tour ................................................................................................. 66 Sewage and Wastewater ............................................................................................................ 67

Sizing - Pressure Boosting ................................................................................................................. 78 General .......................................................................................................................................... 78 The Sizing Wizard, a quick tour ................................................................................................. 78 Pressure Boosting ........................................................................................................................ 79

Sizing – Industrial Applications .......................................................................................................... 86 General .......................................................................................................................................... 86 The Sizing Wizard, a quick tour ................................................................................................. 86 Industrial Applications.................................................................................................................. 87

Sizing - Renewable Energy (WinCAPS only) .................................................................................. 94 Life Cycle Cost Calculations ............................................................................................................... 95

Calculation in five steps............................................................................................................... 95 How does the calculation work ? ............................................................................................... 96 Where can I see the result of the Life Cycle Costs calculation?........................................... 97

Additional sizing options.................................................................................................................... 100 Sizing Summary print................................................................................................................. 100 Sizing of NK pumps according to ISO 5199........................................................................... 100

Service ................................................................................................................................................. 101 General ........................................................................................................................................ 101 Accessing Service Information ................................................................................................. 101 Layout of the Service Window.................................................................................................. 102 Printing Service Information ..................................................................................................... 103

Projects (WinCAPS only) .................................................................................................................. 105 General ........................................................................................................................................ 105 Adding a selection to a project ................................................................................................. 105 Editing your Project .................................................................................................................... 105

Replacement ....................................................................................................................................... 106 General ........................................................................................................................................ 106

Selecting Accessories ....................................................................................................................... 108 General ........................................................................................................................................ 108

Working with Glycol solutions and solutions other than water .................................................... 109 General ........................................................................................................................................ 109 Working with Non Newtonian Liquids ..................................................................................... 110

Page 4: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Introduction General Dear User Thank you for using the CAPS program from Grundfos. The purpose of this program is to offer a complete tool that contains an extensive catalogue of Grundfos products and a sizing program to select the most suitable pump for your application. On top of that there is a comprehensive pump replacement function for heating circulators and the possibility to produce professional quotations including curves, drawings, quotation texts, wiring diagrams etc. You can also export all this in the most popular file formats including gif, bmp, txt, dxf, etc. Last but not least the program contains the instruction and operating manuals for nearly all pumps of Grundfos in multiple languages. Service drawings, exploded views and parts lists are available for all sewage products as well as several other pump types. The program is designed, developed and maintained especially by Grundfos in order to make use of the wide experience of more than half a century designing pumps and knowledge of applications. For the last 20 years Grundfos has developed the CAPS software, so customers and professionals all over the world can share and benefit from this experience. CAPS is available in two version; WinCAPS is available on a CD-ROM and the online version called WebCAPS is available at the Grundfos website - www.grundfos.com . Additional features in WebCAPS include CAD Drawings and Literature.

Who should use this program?

WinCAPS has specific advantages for all professional users

Generally, everybody who is involved with pumps in a professional manner will find this program useful, however there are certain specific groups of users that will benefit especially from this program as mentioned below.

Installers, Well drillers, Industrial end users or Owners of a Grundfos product If you belong to one of these groups then you can use CAPS typically to make selections from the catalogue, by product number or by using the books on the screen. If you do occasionally need to calculate a pump (in sizing), you will probably only use the short standard question catalogue. Also the replacement catalogue can be helpful when you need to replace an existing pump with a Grundfos pump. We advise you to run the program straight from the CD in order to save the space on the hard disk. Planners, Consultants, Engineers, Large installation companies, Pump dealers and Students If you are in one of the above groups you will probably appreciate, apart from the catalogue function, the advanced question catalogues in the sizing program and the ability to make accurate energy consumption calculations based on your own load profile (consumption pattern) You can also make comparisons against existing systems and calculate savings and payback periods. Dimensional drawings can be used as reference in new or replacement projects. Grundfos Staff and Service partners This group uses CAPS as reference for all Grundfos products. Many pumps have exploded views and parts lists connected to them, which are useful when ordering spare parts. Via E-Mail or fax, a salesman, service engineer or wholesaler can send drawings, technical information, manuals and pumping solutions to their customers. Regular updates of the database and the program will always supply the latest information. For news and updates please check. www.grundfos.com or www.grundfos.com/wincapssupport

Page 5: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Disclaimer Grundfos provides CAPS as a service and for information purposes only. The transmission of this information does not create any form of relationship with Grundfos. While we have attempted to maintain the information, the software and any other services in CAPS as accurately as possible, CAPS may contain errors or omissions for which we disclaim any and all liability. The material and contents posted in CAPS is provided without warranty of any kind. Grundfos is not responsible for any loss of hardware, software or files, caused by the use of CAPS or elements downloaded or used from CAPS. Hence Grundfos makes no warranty that CAPS or products or services provided through CAPS, either by Grundfos or on Grundfos' behalf (including free software downloads), will meet your requirements or will be uninterrupted, timely, secure or error-free, or that CAPS or the servers used by Grundfos are free of viruses or bugs or are fully functional or accurate.

Page 6: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

What's new New Products Each version of CAPS holds a complete new set of product data. New products are added, current products are updated and products that are not marketed anymore are removed. For details on which products are added and removed from which versions please go to the CAPS support pages at: www.Grundfos.com/wincapssupport

New functionality Version 2008

Sizing

An overview mode has been introduced as an alternative to the wizard format in Sizing. This provides you with all the questions used in the sizing process. Simply click on the ‘Overview’ or the ‘Wizard’ button when you select your sizing application to switch between the two formats . The main benefit of the Overview format is that it makes the sizing process very short and quick. At its most basic, you only need to enter your required Q and H values within a selected subapplication and then click the ‘Start Sizing’ button to get a result. More advanced users can mark the ‘More’ checkbox to get the complete set of questions:

Renewable sizing has also been updated to the wizard format

Page 7: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

New Functionality Version 7.9

Sizing

The New sizing wizard layout has applied to the sizing of Industrial applications:

Catalogue

Configuration of NB and NK products in Catalogue has been introduced. After selecting either an NB or NK product in Catalogue, click the ‘Advanced’-button to launch the Configuration options

Page 8: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

New Functionality Version 7.8 General The new sizing layout introduced in WinCAPS 7.6, where a `wizard' approach is used to guide the user through the sizing process, has also been applied to the Heating and Air-Conditioning applications in WinCAPS 7.8.

Sizing The new sizing wizard layout is applied to the sizing of Heating applications:

The new sizing wizard layout is applied to the sizing of Air Conditioning applications:

Page 9: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

New Functionality Version 7.6 General In the Help Menu, a section has been added containing legal issues

Renewed Sizing Layout Starting with WinCAPS 7.6, Grundfos introduces an easy to use sizing method base on the so-called "Wizard" concept. This sizing method is also used on the Internet based version of WinCAPS, called WebCAPS. Not all application areas are yet converted to this new method, however the area's that are now available are:

Domestic Water Supply A graphical Interface guides the user through this application area

Groundwater Groundwater sizing now includes the sizing wizard approach to make it more user-friendly to get through the sizing process.

Page 10: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Wastewater The wastewater section is subdivided in several sections as below

Each section again contains a custom graphical menu and selection options

Also a graphical display of choice of impellers facilitates the selection process

Page 11: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

In this application area, rule based accessory and controller assignment is in place. This implies that the proposed accessories and controllers are now in line with the selected pump.

Renewed Layout of Life Cycle Cost Calculation The whole calculation of life cycle costs for these renewed sizing area's is now also based on a step by step wizard approach. The steps and the position in the selection and calculation process are displayed in the top of the screen

Catalogue In the catalogue section it is now possible to switch to the "Advanced" mode, making the "point and click" selection method in the Capacity Range curve available.

Point and Click in the Curve to preselect pumps

The S Series of pumps as well as the TPE(D) Series 2000 are now available in WinCAPS and WebCAPS

Page 12: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Replacement The S Pumps are now also taken up in the replacement list as a possible replacement for the old Large AP Pumps

Page 13: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

WinCAPS Online user training General Interactive user training is available on the Internet in several languages under: www.Grundfos.com/wincapstraining This training, which is in English, German, Spanish, French, Italian, Russian and Chinese, consists of text, spoken video's screenshots and a test per subject. Also available here is a list of known bugs, FAQ's and latest version information on www.Grundfos.com/wincapssupport

Page 14: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Internet Updates (WinCAPS only) General WinCAPS version 2008 will automatically update program patches using the Internet. Go to the Options Menu and choose the Update Tab

Important

This will only update with program patches, bug fixes etc. This update will not import new products or new functionality. For this you would need a complete new version of WinCAPS, check www.Grundfos.com/wincapssupport for info on the latest versions

Page 15: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Installing WinCAPS General

WinCAPS will run Stand Alone from the CD ROM

Normally WinCAPS should start itself automatically when inserted in the CD drive. If this does not happen please run the file "Setup.exe" from the CD (In Windows: Start/Run/Browse, select the CD ROM drive and double click on "Setup.exe"). WinCAPS will start and asks whether you want to run the program from the CD or want to install it on the hard disk.

Important: Even if you want to install the program on the hard disk, always try to run it from the CD first. If for any reason the program will not start or function (see ODBC installation), it will also not run after you installed it on the hard disk. This saves you the time you would otherwise use to install it to the hard disk.

Installation Dialog Box

If you want to install the program on your hard disk, the installation program will guide you through this process. Depending on which functionalities and files you want to install, you will need between 300 and 650 Megabytes.

WinCAPS takes from 300 up to 650 Mb hard disk space, depending on installed options and I/O Manuals

At one point the installation program lets you select which components you want to install (User defined installation) or do a full installation . We recommend always installing the dimensional drawings, product pictures, wiring diagrams and quotation texts because these are relatively small files. When you also want to install the Installation Manuals (Operating and Instruction Manuals) and Service Information please put a checkmark in this box in the left column (see illustration)

and select in the right column the languages you want to have at your disposal. Should you select all languages, this will increase the size of your installation with more than 300 MB!

Page 16: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

If you run WinCAPS from the CD, you will have of course everything at your disposal. The program will create a program group named "Grundfos" from which you can start the program. You can also uninstall WinCAPS from here. Now you're ready to go..........

Uninstalling WinCAPS If you want to remove WinCAPS from your hard disk, you can use the Microsoft Uninstaller (Using Control Panel/Add Remove Programs) or the Uninstall WinCAPS icon that is in the WinCAPS program group (usually located in the Grundfos/WinCAPS program Group) This will bring up a dialog box where you can choose whether to remove the entire program or only parts of it.

Uninstalling parts of the WinCAPS program is now possible

Page 17: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Problems with Installation Acrobat Reader � The instruction manuals in WinCAPS are in the so called PDF format (Portable Document File), which is the de-facto standard for electronic distribution of manuals, and this program needs to be installed on your computer, to display them. If Acrobat Reader � is not yet present on your computer, you can install it from the WinCAPS CD ROM where there are several language versions of this program present (AR*.exe) or download it from www.Adobe.com

ODBC Installation The WinCAPS program uses a Microsoft Access database to store data. To approach this data, Windows needs a so-called ODBC driver. Upon installation WinCAPS checks whether there is already an OBDC driver installed on your computer. If this is not the case, WinCAPS asks if you want to install the ODBC driver that is included on the CD ROM. Also if you run WinCAPS from the CD only, you will still need the ODBC driver installed on your hard disk. After installation of this driver, WinCAPS should function properly. If WinCAPS detects during installation that an ODBC driver is already installed on your system (which is the case with most Windows installations), the installation procedure will continue, or if you want to run the program from CD, the start-up procedure.

Error Messages

It has appeared that in a very limited number of cases that the ODBC driver that is already installed, conflicts with the one that is needed by WinCAPS. This results in error messages such as "Can not make connection to server" or "Server error, Connection Error".

Even though WinCAPS uses standard Microsoft components (also the ODBC drivers are standard components) there can be conflicts if a certain Windows version is installed with a certain version of Microsoft Office using a certain language. As you might know, there are multiple versions of Windows 95, Windows 98, Windows 98 SE, Windows Millennium, Windows 2000, Windows NT and Windows XP. On top of that they can be combined with Office 95, Office 98, Office 2000, and Office XP, which again can be installed in several configurations. All these programs in their different languages can use different ODBC drivers, which in theory should be compatible, but which in practice are sometimes not.

Installing the ODBC driver from the WinCAPS CD ROM could lead to compatibility problems with already installed software

If you want to install the WinCAPS ODBC driver over your existing ODBC driver you can run the installation from the WinCAPS CD ROM. You start this process by running the file "Setup.exe" located in the WinCAPS/Installodbc/Disk1 directory on the CD ROM. Most probably this will have no influence on your already installed software and will allow WinCAPS to function properly, however because of the possible combinations of already installed software on your computer, Grundfos cannot in any way be held responsible for the consequences that this ODBC installation will have on your installed software.

For Windows NT, 2000, XP and Vista users WinCAPS makes a few entries in the Windows registry. If you are a user of Windows NT, Windows 2000 or XP in a network, it can occur that you are not allowed to update this registry, depending on your user profile. This will also trigger the error message "Can not make connection to server" or "Server error, Connection Error". In that case please contact your IT department or network administrator.

Network installation, guidelines for system administrators Small Networks

Page 18: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

If you have a small network, or are sure that never more than a limited number of people (up to 6 or 8 depending on the speed of your network) will work simultaneously with WinCAPS do the following. Copy the complete contents of the directory WinCAPS and all the subdirectories that are on the CD ROM to a directory on your network drive. Then make shortcuts from the users computers to the file "WinCAPS.exe" in the WinCAPS directory on this network drive. Settings and ini files will be automatically stored on the local users computers. The users must have rights to update the registry file.

Client Server Installation on Local Network If you have a slower network, or want to use the program with a large number of users you should make a Client/Server installation.

Note:

Make sure that your network supports the TCP/IP protocol

You must have administrator rights in order to install the program the program on the server

Insert the WinCAPS CD ROM and make a full WinCAPS installation on a server from which you want to run WinCAPS (you can call this directory for instance "W:\WinCAPS Server\" where W is your network drive. This will take up around 600 MB. Go to the directory in which you have installed WinCAPS and run the file NetDBsetup.exe The program will ask you to specify a path to which you want to have the client part copied. Important: You cannot specify a path with a space in it. So you might want to call it " W:\wincapsclient " Now WinCAPS will put the files needed for the client part in this directory (depending on the number of product ranges installed this varies between 20 to 25 Mb) A file called "NetDB.bat" is also created in your WinCAPS Server directory. If you click on this file it will start running the server part of WinCAPS. You will now see in the bottom of your screen a button "WinCAPS NetDB" indicating that the server part is running. Go to a computer on the network that you want to run WinCAPS on, go to the W drive and copy through the network the client part "WinCAPS client" on the local hard drive of this computer. Create a shortcut on this computer to the file "WinCAPS.exe" in the client part on the local drive. Click on the shortcut and WinCAPS will run as Client-Server Application.

Note: Also Install the Acrobat Reader on the local computers; this file is available on the WinCAPS CD.

The settings and projects are stored on the local hard drives; you can check or change these directories in the "Options Menu". In order to make sure that WinCAPS is always available for the network users, include the file "NetDB.bat" in the startup routine of your server, also the performance is enhanced if this server is not used for any other heavy network applications.

Please notice, that this NetDB server program must run all the time, when the WinCAPS data is needed via the network. If the NetDB program is running, a little icon titled "WinCAPS NetDB" is displayed in the task bar in the bottom of the screen.

Page 19: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

How to install and use WinCAPS If a user wants to run WinCAPS on his own PC via the network, he needs to get access to the application part just created by the NetDBSetup program. If the chosen destination path was located on a network drive, the user can just run the WinCAPS.exe file on this network drive from his own PC, and the program should be ready for usage. If there is no access to network drives, the application files should be copied from the chosen destination path on the NetDB machine to the users PC-hard disk. He can then run the WinCAPS.exe from the hard disk, and the application should start.

Note:

To be able to keep the users up to date with the WinCAPS application, it might be an advantage, to select a network drive for the application part of WinCAPS. When a newer version of the WinCAPS CD ROM is available, uninstall the old one on the NetDB machine, and repeat the entire process. Then the next time the users start WinCAPS.exe, it will automatically be updated, if you chose the same destination path for the application part as in the previous version.

Client Server Installation on Local Network (Graphical Instruction) Below is a graphical presentation of the steps for network installation of WinCAPS

Page 20: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals
Page 21: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals
Page 22: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Starting WinCAPS for the first time, Setting the Options Menu General When you are starting WinCAPS for the first time, either from the CD ROM or the hard disk, you can customize the program by using the "Options" menu. A menu will now appear with six tabs, which are Application, Server, Company, Units, Currency and Update.

Options Dialog Box

Setting the tabs Application In this tab you can control some standard program features such as: Language: Here you set the language in which the program will operate. Product Range: This feature controls which countries' product range will be used. Grundfos markets its products worldwide and between countries and continents the product range can vary. For a specific country version that is sent out to customers, there is only 1 choice, for the versions for Grundfos internal use, there can be more product ranges. The full international range (general) holds around 100.000 items. Directories: Here you can control where WinCAPS saves temporary files, the project files and exported data. Show Parts Numbers in Parts List: This feature is not available in all versions and controls whether or not part numbers are shown in the parts list in the exploded views in service drawings

Page 23: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Products for Service Included: Also this feature is not available in all versions. Here the user can control if also data of pump series is displayed that are discontinued but can still be used for service purposes. Extended search panel in the catalogue: Here you choose if you want to have the standard or the extended search panel when you are in the catalogue mode. Display catalog as tree structure: Beside the bookcase, WinCAPS offers now the possibility to display the catalog as a tree structure, similar to the Windows explorer. You can set this preference in the "Options/Application" menu.

Server This tab controls the address of the server on which the WinCAPS database is running. For a normal hard disk or CD ROM operation this is always set to local, however the network administrator can choose to set a different IP address here (see Client Server Installation)

Company Here you can fill in your own companies address etc. This will be used in quotations that you produce. The data is saved in the Windows registry file

Units Here you define which measurement system is used by WinCAPS.

Currency In the "Options/currency" menu, you can change the currency settings of the program. The program will recalculate the prices etc. based on the exchange rate of the Euro.

Important: After you change any of the above settings WinCAPS will do a quick restart. We advice you therefore not to change these settings when you are in the middle of a sizing process or a quotation because you will loose your input. When you are in a quotation and want to change the settings, save your work first!

Update Using this tab you can update your version of WinCAPS using the Internet, please refer to the chapter: Internet Updates.

Page 24: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Getting started with CAPS CAPS consists of 7 main program areas: * Catalogue * Sizing * Service * Replacement * Literature * CAD Drawings * Projects The Catalogue contains pump curves, product pictures, dimensional drawings, wiring diagrams, technical data and quotation texts as well as information on service and part lists for Grundfos products. When clicking on the preferred duty point in the curve viewer, the pump best suited to your hydraulic needs is selected. It is also possible to select a pump from a list of search criteria. The Sizing tools are where Grundfos utilizes its long experience in pump design and application knowledge. This results in a very comprehensive, yet easy to use program that is almost always able to produce a suitable pump for your application. The sizing tools are wizard-based; The wizard contains a number of steps with each step consisting of questions relating to the application you wish to size a pump for. Adjust the values and settings to suit your preferences or simply enter your required Flow and Head values and start the sizing. In Service you can view interactive exploded views and sectional drawings of Grundfos products. In Replacement you can easily find a Grundfos pump to replace your existing pump. Simply select the characteristics of your existing pump from a list of search criteria to see which Grundfos pump to replace it with. Literature contains technical documentation for Grundfos products. You can find a product by either application area or by searching for a specific product number. The technical documentation is available for viewing and download in pdf format. In CAD Drawings you can download technical drawings of Grundfos products in dxf- and dwg formats. You can save your selections and quotations in the Projects part of CAPS and make professional printouts including quotation texts, curves, dimensional drawings etc. It is also possible to add local accessories.

CAPS, a quick tour

How CAPS is built up The catalogue and sizing part of the program are divided in application areas. Allocated to these areas are the Grundfos pump series. If you want to know which series are allocated to which application, go to catalogue and click on an application book. Next will come up the books of the pump series.

Note.

In WinCAPS 7, the Grundfos dosing pumps (if present in the national product range, see above in "Setting the Options menu/Application) are only available through selection in Catalogue. This can also be applicable for certain other product lines such as motors and accessories.

Page 25: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Layout of the screen

CAPS screen areas

After starting up CAPS you can see that the program interface is divided up in several areas (see illustration)

The menu bar.

The five buttons that control the five different program areas

The curve viewer. This part of the screen displays curves, drawings, photo's etc

The text viewer. This is where texts are displayed that is connected to the selected article. When selecting an accessory this will display the accessory information.

The middle button bar, used to close screens, start the sizing process or selection fields in the catalogue.

The result grid/hit list. Here is where the products are shown that are the result of the sizing process or a catalogue selection

The lower button bar. The left side contains the buttons Information and Accessory. When a product is selected either in the catalogue or in sizing, clicking on the Information button will give access to the Operating and Installation instructions of that product, and if available, service drawings, exploded views and parts lists. The right side contains three buttons and a short cut to the print menu. With the button "Start Page" you can go back to the opening screen of the program. The "Add to project button" will add your current selection to a project (see chapter on Projects) and the "View Project" button will take you straight to the project screen.

The File Menu (WinCAPS only) Page setup

Page 26: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Enhance your prints with your own company logo

Here you can define the settings for paper size, numbering etc. You can also have your own company logo above the printouts. By default it will choose the Grundfos logo but by clicking the button next to the "Import Logo" field, you can point to the graphic file that contains your logo. The size should be maximal 800 by 160 pixels.

Export Here you can export parts of your selection to several file formats. The items that can be exported are:

The Hit list. This is the list in the result grid. The export format of the list can be imported in a spreadsheet program by using the import functionality of this spreadsheet program.

Product Picture. Will be exported as gif file.

Dimensional drawing will be exported as a dxf file. The drawings used in WinCAPS are principle sketches with the correct dimensions written in them. This means that you can import them in AutoCAD or any other drawing program, but the files are not sizeable or dimensionally true. If these files are required they can be obtained from the Grundfos Website or on CD ROMS by contacting your local Grundfos Company.

The wiring diagram can be exported as DXF file.

All data, which is for all data related to the product, the export format can be imported in a spreadsheet program by using the import functionality of this spreadsheet program.

Quotation text. This is exported in a format that can be read by all word processing programs.

Print/Export, Printing and Exporting your Selection to email From the file menu, choose the "Print Export" option. This option will be slightly different whether you print out from the Catalogue and the Sizing sections or from the Project section. Printing from the groundwater or service sections opens up customized Print/Export windows. You can select between several possibilities for output, some of them might not be available, and depending on which part of WinCAPS you are printing from.

Powerful export/save facility lets you E Mail your files direct to your customers

Press the button "Preview/Export" to see your print selection on screen. You can export the displayed page as a Gif, JPG, BMP or TIF file, or choose to save the complete output as PDF. After saving the you can send the image or PDF , for instance a dimensional drawing, by E-Mail to your customers.

Page 27: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Create Proffesional Printouts

When printing from the catalogue or the sizing section you can use the "Edit" function in the "Print Export" menu. Now you can edit the quotation text, quantity and price of your selection.

Important: These changes will not be saved. If you want to save the changes, you have to print out from the Project section and of course save the project.

Page 28: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Catalogue General A very powerful feature of CAPS is the catalogue function. Choosing catalogue with the button, a bookcase or tree structure will open that contains books with the names of applications in which you will find your pump. If you are not certain which application holds the pump series you are looking for, you can also choose the book that contains all products.

Selecting a product in the catalogue Selection by product number If you already know a specific product number and want to obtain data, just type the number in the field "Product Nr", located on the left side of the middle button bar (see Layout of the screen), and press the button with the binoculars.

Browsing through the catalogue Select the correct frequency in the middle button bar (default = 50 Hz).

Clicking once on a book will make the book drop from the case and show an application picture.

Clicking twice (double click) on a book will take you one level deeper and show you the product lines that are allocated to the application.

If you click once on a book of a product line, a photo of that particular product range will pop up.

If you click twice on the book you will go one level deeper into that product range.

Again, clicking once on the book will show you a picture of the chosen pump type in the product range; double clicking will bring up a search panel. This search panel is different for every product line and you can choose in the Options menu whether you want the simple or extended search panel.

You can see more data in the catalogue by pressing these buttons

If nothing is selected in the search panel, all products in the selected product line will show up in the result grid. On the right hand of the middle button bar three buttons appear. Clicking these buttons will display different data of the pumps in the result grid (General Data, Mechanical Data and Electrical Data).

Sort your product by clicking on the headings

The products in the result grid can be sorted by clicking on the headings of the columns.

Access Instruction Manuals, Service Drawings and Service Kits

You can highlight a specific product in the result grid with your mouse and you will see the buttons "Information" and "Accessory" lighten up. Clicking on "Information" will give you access to the Installing and Operating instructions

Page 29: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Double clicking on a specific product in the result grid will give you access to the Pump Curve, Dimensional Drawing, Product Picture and Wiring Diagram on the left side of the screen and All Data, Quotation Texts and a System summary on the right side. All this data can be exported, printed or saved in a project.

Important: The accessories are applicable for the whole product line that you selected and not only the pump that is in the result grid. You have to choose the correct accessory yourself from the accessory menu; e.g. if your pump has DN 40 connections, you need to select DN 40 flanges from the flanges database.

If Service information is available for this product number, a button appears under the pump curve.

Double-clicking on a "+" sign in the parts list viewer will reveal a lower level for the kit. Search for EAN Numbers Apart from a product number search, it now also possible to search for a particular EAN number in the catalog.

Click and choose from capacity range A great new feature is the "click and choose" functionality using the graph of the complete range of a certain pump range. You have to activate the "Use the extended search panel in the catalog" function in the "Options" menu.

Page 30: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Capacity range screen

If you select a certain pump series in the catalog, a new window will open, showing the complete capacity range for these models. Clicking anywhere in the graph will result in a pre-selection of certain models of this range, depending on the Q and H.

Copy from the Selection Table (Hit list) If you right-mouse click on a cell in the selection table, the data in this particular cell can be copied to a word processor or a spreadsheet program. For a mass export of the data in the selection table you can still use File/Export/Hit list

Viewing the pump curve in the catalogue area, extensive possibilities Once you selected a pump in the catalogue, the pump curve will appear on the left side of the screen. In this curve screen, very sophisticated features are at your disposal. To begin with, you can click anywhere in the curve area and the duty point and the efficiency of the pump will be calculated immediately, and displayed in right side of the curve screen. If you are looking at the curve of a non-speed controlled pump, the calculated duty point is where the pipe resistance curve crosses the pump curve. If you are looking at the curve of a speed controlled pump (which can be identified by a large blue area), clicking anywhere in this area will give you the requested duty point and the of the pump in this duty point - as percentage of nominal speed

Page 31: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

The button "Curve Settings" activates the next important feature. Clicking this button will show you the Curve Settings Menu with the following possibilities. All curve settings are automatically saved until pressing the "Default Settings" button restores the default values The Curve Setting dialogue is divided into to 5 main areas, which can be accessed by clicking the different tab in the dialogue.

Operating point tab You can choose to have no duty point displayed, the nominal (optimal) duty point or a duty point that you can define yourself. To define a duty point yourself, select Input. If there is already a static pressure in the system, you can input that here as well. The pipe resistance curve will then start from that point on the Y-axis. CAPS will allow you to fill in here a different motor speed in the Nominal Motor Speed field to emulate the effect on the pump curve of an electrical motor that has a different speed than the fitted standard motor. CAPS allows an input of 5% under the original nominal motor speed or up to the synchronous speed (2999 RPM for 2 pole motors, 1499 RPM for 4 pole motors, 999 RPM for 6 pole motors). Impeller For some pumps series (e.g. the NK series long coupled end suction pumps) there is a possibility to show a curve based on an impeller diameter of your choice. (The desired diameter has to be within the limitation for the particular pump, otherwise there will be no curve shown; clearing this field will restore the default values). This is due to the fact that Grundfos can supply these pumps with an impeller machined down to match the exact desired duty point if this is requested

Hydraulic layout tab In this part of the menu you can choose to emulate the curves of maximal six pump working parallel or two pumps working in series.

Page 32: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Variable speed This powerful feature allows you to turn the curve of a non-speed controlled pump into a speed-controlled pump, thereby emulating the effect of an external frequency converter. If this feature is activated, the curve area will turn blue. Clicking in this blue area will show you the duty point together with the corresponding RPM in % of nominal speed in the top right hand corner of the curve. This can serve as a reference point for the frequency setting (Hz) of the external frequency converter. (The slip of the motor has to be taken into account so in reality this setting might vary slightly). If you have selected pumps in parallel, you can select if you want to enable variable speed for one pump only or for all of the pumps in parallel. The Variable speed feature is not available for wet runners or pumps with multiple curves

Fluid tab

In the Pumped liquid field, you can choose from a list predefined medias primary used as Antifreeze/Secondary fluids in heat transfer. If you want to input viscosity and density for the media yourself, select "Any viscous fluid" in the list.

Page 33: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

IMPORTANT: These calculations are only applicable for "Newtonian Liquids", check chapter Working with Glycol Solutions

Basically changing the viscosity will influence the steepness of the curve and adjusting the density will influence the power consumption. However also factors like the design of the pump, duty point, RPM and impeller size play a role in the calculation. When the required power (P2) exceeds the fitted standard motor, the pump curve becomes a dotted line.

Curve types tab

Curve types Depending on the product range and position in the program, some curves may or may not be available. Tolerances The calculation and display of the duty point tolerances has changed. For some pump types no tolerances are displayed and the checkbox in the curve viewer is grayed out. The tolerances that are being displayed are according to ISO 9906 Annex A

Important. Not all curves are available for all pump types and not all Grundfos curves are according ISO 9906 Annex A, for details check your Grundfos dealer or the Grundfos.com website. Depending on the version of CAPS the possibility to display the tolerances may or may not be available

Show control curves Whenever you have a speed controlled pump, this option is available. If it is clicked, further options appear. You can choose between two different control curves - a rectilinear or a square curve form. As default, the control curve is rectilinear. Mark the "Square curve form" to enable this option.

The "Decrease at low flow" input tell CAPS how steep the control curve should be. The value decreases the head value for the control curve at zero flow according the actual head. The "Minimum flow" input tells where to stop the control curve.

Page 34: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Other Curves tab

Show curves for pumps with nearby stages If this box is ticked, also pump curves will be displayed of the same product line with more- or less stages. This functionality is available depending on the product line. Show curves for (other) pumps in the hit list This box is available in Sizing only. If this box is ticked, curves from other pumps in the hit list can be shown in the curve screen. Insert your own QH point Here you can insert manually a QH point and a P1 at this particular point. CAPS will then automatically calculate the efficiency of that pump in this point. This functionality comes in handy when you have to compare an existing pump, of which you know the power consumption at a given QH, with a selection made by CAPS. Default Settings Button This button will restore the default curve settings.

Important: The above features in the curve viewer are only available when you select a pump in the catalogue mode. When you select a pump using the sizing process, some features are not available.

Multiple Curves In case you want to modify your pump performance curve sheet to include more information you should enter the Curve settings. The options you select here will be shown in the curve viewer and in your print-outs as well. By activating the function "show curves for (other) pumps in the hit list" in the Curve settings window, you can compare different pumps from the hit list. By selecting the "show curves for nearby stages" in the Curve settings you will get the option to see more curves for pumps with more or less stages in comparison with the sized pump curve. By clicking any place in the curve viewer, the nearest pump curve will show up when this function is activated.

Curves for electro motors From WinCAPS version 7.42 also curves for electro motors will be displayed. Initially this functionality has only been enabled for the submersible motor series MS and MMS.

Page 35: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

New display of motor curve You can access these curves using the "Motor Curves" tab

Page 36: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Sizing - Heating Getting started with Sizing The sizing tool is where Grundfos utilizes its long experience in pump design and application knowledge. This results in a very comprehensive, yet easy to use program that is almost always able to produce a suitable pump for your application. The sizing tool is divided in 8 main application area's that are again subdivided in sub application areas. Depending on which market or country CAPS is used, applications and sub applications can vary. Each application comes with its own specific question catalogue.

An important feature of these question catalogues is the possibility to quickly select a pump using only basic input concerning Head and Flow, make advanced calculations with regard to energy consumption, payback periods, load profiles, cost of ownership etc.

The Sizing Wizard, a quick tour The Sizing Wizard basics A sizing wizard is a guide intended to help the user narrow down and find the right product for his needs.

The wizard contains a number of steps with each step consisting of questions relating to the application you wish to size a pump for. Adjust the values and settings to suit your preferences or simply enter your required Flow and Head values and start the sizing. However, some input fields are interdependent, so we recommend you to follow the order suggested in the program.

Use the `Next' and `Back' buttons to navigate between the steps in the wizard.

Click the `Start sizing' button. Calculations will be carried out on the basis of your input.

After a few seconds, a list of relevant pump solutions is displayed at the bottom of the screen, ranked in order of relevance. You can then access further details by double clicking your preferred pump solution.

Page 37: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Click the button Some of the input fields have a button next to them.

When you click the button, a sub-window will appear, allowing you to enter additional input or perform a calculation. Entering extra input here will ensure even more accurate and detailed sizing calculations and printout data.

Saving and loading Settings in Sizing All the input that you make in a wizard, such as head, flow, a load profile, etc. can be saved using the "Save as" button. These settings can be reloaded again using the "Open" button.

Default settings CAPS allows you to set and save your own default settings within each sizing wizard. When you mark the `Use as default sizing input' in the `Save sizing input' dialogue, all your input in the sizing wizard, except for Flow and Head, will be reloaded the next time, you enter the sizing wizard.

Heating The heating sizing area is mainly used to select pumps for domestic, commercial or district heating as well as industrial plant service systems. Selecting the application area is the first step of the wizard

Page 38: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Select type of Installation Within each application area the user can select the type of installation he wants to size a pump for. The types of installations are divided into groups to make it easier for the user to find the correct installation type.

Your Requirements At this step, the user can enter the Flow and Head values, which are essential in the sizing process.

Page 39: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

If the user does not know the exact Flow and Head values, two calculators are available to help define the values (available in Commercial Buildings, but not District Heating). The Flow calculator

Enter the values that apply to your system and click OK to get a calculated flow value. The Head calculator

Page 40: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Enter the values that apply to your system and click OK to get a calculated head value. Besides Head and Flow, there are other settings in Your Requirements: Max. liquid temperature: This input not only includes or excludes certain pump ranges; it also determines the choice of seal. Max. operation pressure: This input sets the maximum operation pressure for the system. Min. and max. inlet pressure: Here CAPS checks if the minimum inlet pressure, combined with the vapor pressure of the liquid at the maximum liquid temperature and the flow that was specified, is still within the NPSH limits. In other words, depending on the pump type, if the inlet pressure is too low, combined with a certain liquid temperature and flow, there is danger of cavitation. Therefore CAPS will exclude pump types with NPSH values that are not within this range anymore. This can cause wet runners to be excluded from certain selections. Note! Once the Flow and Head values have been entered, the `Start sizing' button is activated and it is possible to get a recommendation.

Control mode Select the control mode, which is most suitable for your selected type of installation. By default, WinCAPS has selected the control mode most often used for the selected type of installation, but the user can always select another control mode. The available control modes are defined by the input, the user has made earlier in the wizard, so it is not possible to select a control mode that cannot be used for the selected type of installation. The user can also decide if a frequency converter should be included and if it should be integrated or external.

Load Profile An important feature in CAPS Sizing is the ability to provide an accurate calculation of energy consumption based on a given load profile.

Page 41: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

CAPS lets you select between different load profiles; the `Standard profile' is a heating pump profile, while the `Full load' profile sees the pump always operating at a fixed duty point. You can also define your own load profile by selecting `User profile' and edit the values in the input fields.

You can also alter the length of the Heating season, which is used in the calculation of the energy consumption.

Configuration At this step you define you define the configuration of your system.

Select `Single' if you prefer one pump. Select `Twin pump' if you prefer two pumps in alternating operation or with a second pump in standby.

Page 42: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Select `2 pumps' if you prefer two pumps in parallel operation, which means that the total requested capacity is divided over the two pump heads. If the user selects `Parallel', a set of additional questions appears allowing the user to set the total number of pumps and number of pumps in standby.

Pump design If the user has a preference concerning pump material, this can be set in the drop down menu. Choose between Inline Canned Rotor type (wet runners), Inline and End Suction, close coupled (dry runners) and End Suction, long coupled (base plate pumps). If you select the long coupled pumps and additional questions will appear concerning the desired coupling type.

Operational conditions At this step, the user can set the operational conditions for the pump including frequency, phase, power supply and voltage. CAPS will take these conditions into account when a reaching a sizing result.

Page 43: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Hit list settings At this step, the user can set hit list settings for the outcome of the sizing process. This is also the last step before the sizing result reached.

Limit search to..: This gives the user the option of pre-setting the outcome of the sizing process based on the inputs made previously in the sizing process. Include particular pump in hitlist: This gives the user the option of pre-selecting a specific pump to be included in the hitlist. This can be useful for comparing a known pump with the sizing result. Allow uncontrolled: If this option is marked, then an uncontrolled pump can also be included in the hitlist provided it meets the requirements set by the user during the sizing process. Max. hits per product group: Set the number of hits allowed per product group Max. hits total: Set the total number of hits wanted in the hit list. Evaluation criterion: The order of the results after pressing the `Start sizing' button depends on the "Evaluation Criterion" settings. By default this setting will be set to `Price + energy costs', but it is also possible to order the results in the hit list by `energy consumption' alone. Energy price: Set the energy price used to order the sizing results in the hit list Calculation period: Set the number of years used in the Life Cycle Cost calculation

Grundfos recommends This is the result of the sizing wizard's calculations. The left column in the window shows an input overview detailing the inputs entered at the different steps in the wizard. The right column of the window (below Grundfos recommends) shows the recommended pump followed by the quotation text describing the pump

Page 44: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals
Page 45: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Sizing - Air Conditioning Getting started with Sizing The sizing tool is where Grundfos utilizes its long experience in pump design and application knowledge. This results in a very comprehensive, yet easy to use program that is almost always able to produce a suitable pump for your application. The sizing tool is divided in 8 main application area's that are again subdivided in sub application areas. Depending on which market or country CAPS is used, applications and sub applications can vary. Each application comes with its own specific question catalogue.

An important feature of these question catalogues is the possibility to quickly select a pump using only basic input concerning Head and Flow, make advanced calculations with regard to energy consumption, payback periods, load profiles, cost of ownership etc.

The Sizing Wizard, a quick tour The Sizing Wizard basics A sizing wizard is a guide intended to help the user narrow down and find the right product for his needs.

The wizard contains a number of steps with each step consisting of questions relating to the application you wish to size a pump for. Adjust the values and settings to suit your preferences or simply enter your required Flow and Head values and start the sizing. However, some input fields are interdependent, so we recommend you to follow the order suggested in the program.

Use the `Next' and `Back' buttons to navigate between the steps in the wizard.

Click the `Start sizing' button. Calculations will be carried out on the basis of your input.

After a few seconds, a list of relevant pump solutions is displayed at the bottom of the screen, ranked in order of relevance. You can then access further details by double clicking your preferred pump solution.

Page 46: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Click the button Some of the input fields have a button next to them.

When you click the button, a sub-window will appear, allowing you to enter additional input or perform a calculation. Entering extra input here will ensure even more accurate and detailed sizing calculations and printout data.

Saving and loading Settings in Sizing All the input that you make in a wizard, such as head, flow, a load profile, etc. can be saved using the "Save as" button. These settings can be reloaded again using the "Open" button.

Default settings CAPS allows you to set and save your own default settings within each sizing wizard. When you mark the `Use as default sizing input' in the `Save sizing input' dialogue, all your input in the sizing wizard, except for Flow and Head, will be reloaded the next time, you enter the sizing wizard.

Air-Conditioning The Air Conditioning sizing area is mainly used to select pumps for commercial buildings or industrial plant service systems. Selecting the application area is the first step of the wizard

Page 47: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Select type of Installation Within each application area the user can select the type of installation he wants to size a pump for. The types of installations are divided into groups to make it easier for the user to find the correct installation type.

Your Requirements At this step, the user can enter the Flow and Head values, which are essential in the sizing process.

Page 48: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Besides Head and Flow, there are other settings in Your Requirements: Max. liquid temperature: This input not only includes or excludes certain pump ranges; it also determines the choice of seal. Max. operation pressure: This input sets the maximum operation pressure for the system. Min. and max. inlet pressure: Here CAPS checks if the minimum inlet pressure, combined with the vapor pressure of the liquid at the maximum liquid temperature and the flow that was specified, is still within the NPSH limits. In other words, depending on the pump type, if the inlet pressure is too low, combined with a certain liquid temperature and flow, there is danger of cavitation. Therefore CAPS will exclude pump types with NPSH values that are not within this range anymore. This can cause wet runners to be excluded from certain selections. Note! Once the Flow and Head values have been entered, the `Start sizing' button is activated and it is possible to get a recommendation.

Control mode Select the control mode, which is most suitable for your selected type of installation. By default, CAPS has selected the control mode most often used for the selected type of installation, but the user can always select another control mode. The available control modes are defined by the input, the user has made earlier in the wizard, so it is not possible to select a control mode that cannot be used for the selected type of installation. The user can also decide if a frequency converter should be included and if it should be integrated or external.

Page 49: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Load Profile An important feature in CAPS Sizing is the ability to provide an accurate calculation of energy consumption based on a given load profile.

CAPS lets you select between different load profiles; the `Standard profile' is a heating pump profile, while the `Full load' profile sees the pump always operating at a fixed duty point. You can also define your own load profile by selecting `User profile' and edit the values in the input fields.

You can also alter the length of the Heating season, which is used in the calculation of the energy consumption.

Configuration

Page 50: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

At this step you define you define the configuration of your system.

Select `Single' if you prefer one pump. Select `Twin pump' if you prefer two pumps in alternating operation or with a second pump in standby. Select `2 pumps' if you prefer two pumps in parallel operation, which means that the total requested capacity is divided over the two pump heads. If the user selects `Parallel', a set of additional questions appears allowing the user to set the total number of pumps and number of pumps in standby.

Pump design If the user has a preference concerning pump material, this can be set in the drop down menu. Choose between Inline Canned Rotor type (wet runners), Inline and End Suction, close coupled (dry runners) and End Suction, long coupled (base plate pumps). If you select the long coupled pumps and additional questions will appear concerning the desired coupling type.

Operational conditions

Page 51: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

At this step, the user can set the operational conditions for the pump including frequency, phase, power supply and voltage. CAPS will take these conditions into account when a reaching a sizing result.

Hit list settings At this step, the user can set hit list settings for the outcome of the sizing process. This is also the last step before the sizing result reached.

Limit search to..: This gives the user the option of pre-setting the outcome of the sizing process based on the inputs made previously in the sizing process. Include particular pump in hitlist: This gives the user the option of pre-selecting a specific pump to be included in the hitlist. This can be useful for comparing a known pump with the sizing result. Allow uncontrolled: If this option is marked, then an uncontrolled pump can also be included in the hitlist provided it meets the requirements set by the user during the sizing process. Max. hits per product group: Set the number of hits allowed per product group Max. hits total: Set the total number of hits wanted in the hit list.

Page 52: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Evaluation criterion: The order of the results after pressing the `Start sizing' button depends on the "Evaluation Criterion" settings. By default this setting will be set to `Price + energy costs', but it is also possible to order the results in the hit list by `energy consumption' alone. Energy price: Set the energy price used to order the sizing results in the hit list Calculation period: Set the number of years used in the Life Cycle Cost calculation

Grundfos recommends This is the result of the sizing wizard's calculations.

The left column in the window shows an input overview detailing the inputs entered at the different steps in the wizard. The right column of the window (below Grundfos recommends) shows the recommended pump followed by the quotation text describing the pump

Page 53: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Sizing - Groundwater Supply Getting started with Sizing The sizing tool is where Grundfos utilizes its long experience in pump design and application knowledge. This results in a very comprehensive, yet easy to use program that is almost always able to produce a suitable pump for your application. The sizing tool is divided in 8 main application area's that are again subdivided in sub application areas. Depending on which market or country CAPS is used, applications and sub applications can vary. Each application comes with its own specific question catalogue.

An important feature of these question catalogues is the possibility to quickly select a pump using only basic input concerning Head and Flow, make advanced calculations with regard to energy consumption, payback periods, load profiles, cost of ownership etc.

The Sizing Wizard, a quick tour The Sizing Wizard basics A sizing wizard is a guide intended to help the user narrow down and find the right product for his needs.

The wizard contains a number of steps with each step consisting of questions relating to the application you wish to size a pump for. Adjust the values and settings to suit your preferences or simply enter your required Flow and Head values and start the sizing. However, some input fields are interdependent, so we recommend you to follow the order suggested in the program.

Use the `Next' and `Back' buttons to navigate between the steps in the wizard.

Click the `Start sizing' button. Calculations will be carried out on the basis of your input.

After a few seconds, a list of relevant pump solutions is displayed at the bottom of the screen, ranked in order of relevance. You can then access further details by double clicking your preferred pump solution.

Page 54: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Click the button Some of the input fields have a button next to them.

When you click the button, a sub-window will appear, allowing you to enter additional input or perform a calculation. Entering extra input here will ensure even more accurate and detailed sizing calculations and printout data.

Saving and loading Settings in Sizing All the input that you make in a wizard, such as head, flow, a load profile, etc. can be saved using the "Save as" button. These settings can be reloaded again using the "Open" button.

Default settings CAPS allows you to set and save your own default settings within each sizing wizard. When you mark the `Use as default sizing input' in the `Save sizing input' dialogue, all your input in the sizing wizard, except for Flow and Head, will be reloaded the next time, you enter the sizing wizard.

Groundwater Select type of Installation At this step the user selects the type of installation he wants to size a pump for. The types of installations are divided into three groups to make it easier for the user to find the correct installation type. The three groups are Borehole, Reservoir and Submersible in Sleeve.

Page 55: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Your Requirements At this step, the user can enter the Flow and Head values, which are essential in the sizing process. If the user does not know the exact values beforehand, two calculators are available to help set the values.

The Flow calculator

Page 56: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

The Flow calculator allows you to adjust the unit used to describe the capacity requirement (days or years). You can also enter data on operating hours and days. Input for flow oversize and flow undersize makes it possible for you to define how close you want the pump solution should be to the required duty point. But note that a too narrow band could limit the output and thus exclude the most energy optimal solution. The Head calculator

The required pumping Head calculator lets you enter more detailed information about head. It will also support calculations of total head. Entering data for Test flow enables the programme to take into account that the dynamic water level varies depending on the actual flow.

Note that calculations concerning the electrical cable diameter are also carried out here.

Besides Flow and Head other settings are also included at this step: Variable speed: By entering "yes" in the Variable speed input field; you can include the efficiency of a frequency converter in your calculations. The required speed (Hz) of the pump will then be calculated and the performance curve at this speed will be shown. Allowed flow over- and undersize: Here you can define in percentage, how much you allow for under or over dimensioning.

Page 57: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Configuration The Configuration step enables you to configure your pump in regard to connection type, pump material and motor type.

Operational conditions At this step of the wizard, the user can set operational conditions for the pump including frequency, phase and voltage. CAPS will take these conditions into account when a reaching a sizing result.

Besides the electrical data, the user can also set the preferred Life Cycle Cost settings: Evaluation criterion: The order of the results after pressing the `Start sizing' button depends on the "Evaluation Criterion" settings. By default this setting will be set to `Price + energy costs', but it is also possible to order the results in the hit list by `energy consumption' alone. Energy price: Set the energy price used to order the sizing results in the hit list Calculation period: Set the number of years used in the Life Cycle Cost calculation

Page 58: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Hit list settings At this step, the user can set hit list settings for the outcome of the sizing process. This is also the last step before the sizing result reached. Limit search to..: This gives the user the option of pre-setting the outcome of the sizing process based on the inputs made previously in the sizing process.

Include particular pump in hitlist: This gives the user the option of pre-selecting a specific pump to be included in the hitlist. This can be useful for comparing a known pump with the sizing result.

Max. hits per product group: Set the number of hits allowed per product group Max. hits total: Set the total number of hits wanted in the hit list.

Grundfos recommends This is the result of the sizing wizard's calculations.

Page 59: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

The left column in the window shows an input overview detailing the inputs entered at the different steps in the wizard. The right column of the window (below Grundfos recommends) shows the recommended pump followed by the quotation text describing the pump

Tip

By clicking with your right mouse button, you can save results from the hit list in your clipboard and from there, paste it into for instance a spreadsheet.

How to calculate the drawdown of a well in Groundwater section If the Static water level (at test flow) is 80m and the Dynamic water level (at test flow) is 100m, drawdown is 20m (80 to 100M) and when the test is done at 120 m3/h Test flow (from drilling report) the specific capacity is 6m3/h/m. If dimensioning flow Q=60m3/h is chosen this means that the drawdown is 60/6 = 10m and the dynamic level is 90m. This head will be used by CAPS to calculate the correct pump. CAPS will display the calculated drawdown of the well at the dimensioning flow in the Sizing Result screen, as well as the specific capacity of the well. The rules are as follows: If the "Test Flow from drilling report" field is empty, it is assumed that the dimensioning flow is also the test flow. The drawdown and specific capacity are calculated from the dimensioning flow.

If the "Dynamic Water Level at test Flow" field is empty, it is assumed that the static water level is also the dynamic water level and there is no drawdown and no specific capacity

Page 60: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Sizing - Domestic Water Supply Getting started with Sizing The sizing tool is where Grundfos utilizes its long experience in pump design and application knowledge. This results in a very comprehensive, yet easy to use program that is almost always able to produce a suitable pump for your application. The sizing tool is divided in 8 main application area's that are again subdivided in sub application areas. Depending on which market or country CAPS is used, applications and sub applications can vary. Each application comes with its own specific question catalogue.

An important feature of these question catalogues is the possibility to quickly select a pump using only basic input concerning Head and Flow, make advanced calculations with regard to energy consumption, payback periods, load profiles, cost of ownership etc.

The Sizing Wizard, a quick tour The Sizing Wizard basics A sizing wizard is a guide intended to help the user narrow down and find the right product for his needs.

The wizard contains a number of steps with each step consisting of questions relating to the application you wish to size a pump for. Adjust the values and settings to suit your preferences or simply enter your required Flow and Head values and start the sizing. However, some input fields are interdependent, so we recommend you to follow the order suggested in the program.

Use the `Next' and `Back' buttons to navigate between the steps in the wizard.

Click the `Start sizing' button. Calculations will be carried out on the basis of your input.

After a few seconds, a list of relevant pump solutions is displayed at the bottom of the screen, ranked in order of relevance. You can then access further details by double clicking your preferred pump solution.

Page 61: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Click the button Some of the input fields have a button next to them.

When you click the button, a sub-window will appear, allowing you to enter additional input or perform a calculation. Entering extra input here will ensure even more accurate and detailed sizing calculations and printout data.

Saving and loading Settings in Sizing All the input that you make in a wizard, such as head, flow, a load profile, etc. can be saved using the "Save as" button. These settings can be reloaded again using the "Open" button.

Default settings CAPS allows you to set and save your own default settings within each sizing wizard. When you mark the `Use as default sizing input' in the `Save sizing input' dialogue, all your input in the sizing wizard, except for Flow and Head, will be reloaded the next time, you enter the sizing wizard.

Domestic Water Supply This wizard is designed for those who are looking for a solution for potable water supply to a private home. This could be from a well, tank or other source, with or without suction lift.

Select type of Installation The wizard contains seven sub applications covering boost up from break tank, boost down from roof tank, boost direct from mains, transport to roof tank, rainwater and water supply from well < or > 8 m.

Page 62: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Your Requirements At this step, the user can enter the Flow and Head values, which are essential in the sizing process. If the user does not know the exact Head value, a calculator is available to help define the value.

The Head calculator

Simply enter the values that apply to your system and click `OK' to get the calculated Head value.

Select system design

Page 63: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

At this step, the user can specify requirements for the system design such as dry running protection, adjustable pressure, self priming, automatic restart etc. depending on the selected type of installation at an earlier step in the wizard.

Operational conditions At this step of the wizard, the user can set operational conditions for the pump including frequency, phase and voltage. CAPS will take these conditions into account when reaching a sizing result.

Besides the electrical data, the user can also set the preferred Life Cycle Cost settings: Evaluation criterion: The order of the results after pressing the `Start sizing' button depends on the "Evaluation Criterion" settings. By default this setting will be set to `Price + energy costs', but it is also possible to order the results in the hit list by `energy consumption' alone. Pump operating time: Set the number of hours per year when the pump is in operation. Energy price: Set the energy price used to order the sizing results in the hit list.

Hit list settings

Page 64: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

At this step, the user can set hit list settings for the outcome of the sizing process. This is also the last step before the sizing result reached.

Limit search to..: This gives the user the option of pre-setting the outcome of the sizing process based on the inputs made previously in the sizing process.

Include particular pump in hitlist: This gives the user the option of pre-selecting a specific pump to be included in the hitlist. This can be useful for comparing a known pump with the sizing result.

Grundfos recommends This is the result of the sizing wizard's calculations.

Page 65: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

The left column in the window shows an input overview detailing the inputs entered at the different steps in the wizard. The right column of the window (below Grundfos recommends) shows the recommended pump followed by the quotation text describing the pump

Page 66: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Sizing - Wastewater Getting started with Sizing The sizing tool is where Grundfos utilizes its long experience in pump design and application knowledge. This results in a very comprehensive, yet easy to use program that is almost always able to produce a suitable pump for your application. The sizing tool is divided in 8 main application area's that are again subdivided in sub application areas. Depending on which market or country CAPS is used, applications and sub applications can vary. Each application comes with its own specific question catalogue.

An important feature of these question catalogues is the possibility to quickly select a pump using only basic input concerning Head and Flow, make advanced calculations with regard to energy consumption, payback periods, load profiles, cost of ownership etc.

The Sizing Wizard, a quick tour The Sizing Wizard basics A sizing wizard is a guide intended to help the user narrow down and find the right product for his needs.

The wizard contains a number of steps with each step consisting of questions relating to the application you wish to size a pump for. Adjust the values and settings to suit your preferences or simply enter your required Flow and Head values and start the sizing. However, some input fields are interdependent, so we recommend you to follow the order suggested in the program.

Use the `Next' and `Back' buttons to navigate between the steps in the wizard.

Click the `Start sizing' button. Calculations will be carried out on the basis of your input.

After a few seconds, a list of relevant pump solutions is displayed at the bottom of the screen, ranked in order of relevance. You can then access further details by double clicking your preferred pump solution.

Page 67: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Click the button Some of the input fields have a button next to them.

When you click the button, a sub-window will appear, allowing you to enter additional input or perform a calculation. Entering extra input here will ensure even more accurate and detailed sizing calculations and printout data.

Saving and loading Settings in Sizing All the input that you make in a wizard, such as head, flow, a load profile, etc. can be saved using the "Save as" button. These settings can be reloaded again using the "Open" button.

Default settings CAPS allows you to set and save your own default settings within each sizing wizard. When you mark the `Use as default sizing input' in the `Save sizing input' dialogue, all your input in the sizing wizard, except for Flow and Head, will be reloaded the next time, you enter the sizing wizard.

Sewage and Wastewater Grundfos offers a complete range of sewage and wastewater pumps, from cellar draining pumps up to wastewater pumps from 600 kW and 10.000 m3 per hour (The presence of these bigger pumps in CAPS depends on local circumstances), complete with accessories.

Select application area This is the first step of the Wastewater sizing wizard and at this step, the user selects the application area: Commercial buildings, Domestic buildings or Municipal wastewater. The further questions in the sizing wizard

Page 68: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

will be based on this selection and adapted to the selected application area and also narrowed down to the suitable pump ranges and pump types.

Select subapplication Each application area includes a number of sub-applications indicated by the dotted boxes on the screen. Point the mouse to one of the dotted boxes for a second to see a small description of the sub-application. Select a sub-application and you can further narrow down the field of possible pump types based on default values of minimum free passage and usability within the selected sub-application.

Select type of Installation Select type of installation by either clicking once on one of the illustrations and then clicking the Next button or simply by double-clicking on the illustration of the preferred type of installation. For all wastewater sub-applications the main selection is between submerged or dry-installed pumps.

Page 69: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Configuration Specify how many pumps and standby pumps you need to get the required flow. Please note that if more than one pump is required, the result of the sizing calculation will contain pumps of the same type. However, in some sub-applications in the municipal wastewater application area you can choose to add a larger standby pump.

Total number of pumps: Select how many pumps of the same size you want. In some sub-applications in the municipal wastewater application area you can even size a standby pump (bigger pump for heavy rains, flooding, etc.) Of these: number of standby pumps: Select how many standby pumps you want. Number of pumps minus number of standby pumps = number of pumps required to reach the specified flow. In later steps you can see the flow velocity and the performance curves for 1 pump, 2 pumps.... or all pumps in operation.

Select type of Hydraulic, Material and Motor

Page 70: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Depending on the application area and sub-application selected, the wizard contains steps for the selection of hydraulic design, materials and motor. At each step, select your preferences. This further narrows the range of available pumps.

Your Requirements Enter your required flow and head values (discharge flow and geodetic head). CAPS now has all the information needed to present you with a list of pumps matching your requirements.

Discharge Flow: Discharge flow is defined as the flow to be delivered by the system. If the calculator for assumed inlet flow is used, CAPS automatically adds a safety factor of 15% when converting this into discharge flow. Geodetic Head: Geodetic head is the actual physical difference in height between the average liquid level in the pit and the highest point of the discharge pipe (or average water level in the receiving vessel).

Page 71: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Pipe friction losses: Friction losses are defined as loss of pressure in the pipeline as well as from the various fittings in the pipeline. Different calculators for both friction losses and flow velocity in all possible situations are available. Allowed undersize: A flow rate x% below the required is accepted Calculators The wastewater sizing wizard offers a number of calculators to provide you with a guideline for the possible discharge flow and pipe friction losses. Calculating the discharge flow To calculate the discharge flow, click on the calculator next to the discharge flow input field. When opening the calculator for estimated inlet flow you get the option of calculating different kinds of inlet flow. In commercial buildings, sewage sub-application you will see two calculators, one for surface water discharge flow and one for wastewater discharge flow.

The surface water discharge flow calculator requires a number of inputs:

Selected area: Based on the risk of damage by heavy rain you can select either a flat or a mountainous type of area. Rated rainwater intensity is Flat = 0.014 l/s/m2 Mountainous = 0.023 l/s/m2. Roof area: The horizontal projection of the roof area.

Page 72: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Vertical area: Vertical surfaces are exposed to heavy showers. Vertical surfaces are typically walls pointing towards the prevailing wind direction. Catchment area: The horizontal projection of the catchment area. Type of catchment area: The quantity of rainwater that will reach the pit or collecting tank depends on the type of catchment area: Concrete: Discharge coefficient: 1.0 Gravel and grass: Discharge coefficient: 0.8 Gravel: Discharge coefficient: 0.6 Garden: Discharge coefficient: 0.1 Click OK and the calculator returns both an inlet flow and a discharge flow value incorporating a calculated safety margin of 15%.

The wastewater discharge flow calculator enables you to estimate the wastewater flow according to the EN 12056-2 standard. All you have to do is define the type of building and enter the number of draw-off points:

Typical frequency factors associated with different applications: Office or guesthouse: Frequency factor K=0.5 for intermittent usage

Page 73: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Hospital, school or hotel: Frequency factor K=0.7 for frequent usage Toilet and/or showers open to public: Frequency factor K=1.0 for heavy usage Laboratory: Frequency factor K=1.2 for special usage Calculating the pipe friction losses Click on the calculator to the right of the pipe friction losses input field.

The calculation of friction losses consists of three calculations: Pipe friction losses in the pit, in the manifold and outside the pit. The first step is to select the pipe material used in the pit and for the manifold. Click the drop-down button and select your pipe material. Pipe friction losses in the pit To calculate the pipe friction losses in the pit, enter the data for the pipe system inside the pit. At the bottom of the window you will get a recommended (pipe) diameter based on the recommended flow velocity. If there is a pipe with a different diameter inside the pit you can add this in line B. The roughness of the pipe is based on your selection of pipe material.

To calculate losses incurred from single resistances, please use the calculator in the Zeta column. Enter the number of single-resistance losses in your pipe system inside the pit in this window:

Page 74: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Pressure loss in the manifold calculator To calculate the pressure loss in the manifold, select diameter DN, connection type and expansion. Minimum and maximum liquid velocity (v min and v max) will appear as you select the various connections. The calculated pressure loss in the manifold will appear at the bottom of the window.

Pipe friction losses outside the pit calculator To calculate the pipe friction losses outside the pit, enter the data for the pipe system outside the pit.

Page 75: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Enter the pipe length, select pipe material and pipe size. At the bottom of the window you even get a suggestion for a recommended pipe diameter based on the calculation of the flow velocity. Similarly to the pipe-friction-losses-in-the-pit calculator, you can calculate the losses from single resistances in your system outside the pit by using the calculator in the Zeta column. If you want to change the pipe diameter, just add a pipe 2, 3, 4, 5, 6 or 7 and enter the characteristics of that particular pipe. You can check the flow velocity in the pipe for 1 to 6 pumps in operation by selecting the number of pumps in operation. When all the calculations are made, go back to the Your requirements-window. The Start sizing-button will now be active, and you can go straight to the sizing result by clicking this button.

Operational Conditions Enter the data for your power supply in order to narrow down the number of recommendations.

If you wish to make a calculation of life cycle costs, enter the basic data concerning energy price, calculation period and the pumps operating hours.

Page 76: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Hit list Settings Here you can choose a specific pump to be included in the hit list. If you do so you can compare an evaluation of the system using this pump against the best hit. Here you also select evaluation criterion for your hit list and limit the search to a specific pump type.

Grundfos recommends Here is the result of the sizing wizard's calculations

The left column in the window shows an input overview detailing the inputs entered at the different steps in the wizard.

Page 77: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

The right column of the window (below Grundfos recommends) shows the recommended pump followed by the quotation text describing the pump

Assignment of accessories and controls When you have finished sizing, click the Next-button once to select accessories and twice to select controls suitable for the selected pump. The lists for selecting accessories and controls are rule based. This ensures that can only select accessories or controls suitable for your selected pump.

Page 78: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Sizing - Pressure Boosting General The sizing tool is where Grundfos utilizes its long experience in pump design and application knowledge. This results in a very comprehensive, yet easy to use program that is almost always able to produce a suitable pump for your application. The sizing tool is divided in 8 main application area's that are again subdivided in sub application areas. Depending on which market or country CAPS is used, applications and sub applications can vary. Each application comes with its own specific question catalogue.

An important feature of these question catalogues is the possibility to quickly select a pump using only basic input concerning Head and Flow, make advanced calculations with regard to energy consumption, payback periods, load profiles, cost of ownership etc.

The Sizing Wizard, a quick tour The Sizing Wizard basics A sizing wizard is a guide intended to help the user narrow down and find the right product for his needs.

The wizard contains a number of steps with each step consisting of questions relating to the application you wish to size a pump for. Adjust the values and settings to suit your preferences or simply enter your required Flow and Head values and start the sizing. However, some input fields are interdependent, so we recommend you to follow the order suggested in the program.

Use the `Next' and `Back' buttons to navigate between the steps in the wizard.

Click the `Start sizing' button. Calculations will be carried out on the basis of your input.

After a few seconds, a list of relevant pump solutions is displayed at the bottom of the screen, ranked in order of relevance. You can then access further details by double clicking your preferred pump solution.

Page 79: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Click the button Some of the input fields have a button next to them

When you click the button, a sub-window will appear, allowing you to enter additional input or perform a calculation. Entering extra input here will ensure even more accurate and detailed sizing calculations and printout data.

Saving and loading Settings in Sizing All the input that you make in a wizard, such as head, flow, a load profile, etc. can be saved using the "Save as" button. These settings can be reloaded again using the "Open" button.

Default settings CAPS allows you to set and save your own default settings within each sizing wizard. When you mark the `Default Settings'-option in the `Save sizing input' dialogue, all your input in the sizing wizard, except for Flow and Head, will be reloaded the next time, you enter the sizing wizard.

Pressure Boosting The Pressure Boosting sizing area is used to select pumps for commercial buildings, industrial plant service systems, municipal water supply and irrigation. Selecting the application area is the first step of the wizard

Page 80: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Select Subapplication The next step of the Pressure Boosting sizing concerns the selection of the sub-application. Each application area contains a number of sub-applications to make it easier for you to identify the application you want to size a pump for.

Your Requirements At this step, the user can enter the Flow and Discharge pressure values, which are essential in the sizing process.

Page 81: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Besides Flow and Discharge Pressure, there are other settings in Your Requirements: Min and Max. liquid temperature: This input not only includes or excludes certain pump ranges; it also determines the choice of seal. Min. and max. inlet pressure: Here CAPS checks if the minimum inlet pressure, combined with the vapor pressure of the liquid at the maximum liquid temperature and the flow that was specified, is still within the NPSH limits. In other words, depending on the pump type, if the inlet pressure is too low, combined with a certain liquid temperature and flow, there is danger of cavitation. Therefore CAPS will exclude pump types with NPSH values that are not within this range anymore. This can cause wet runners to be excluded from certain selections. Allowed undersize: Include pump systems in the sizing result hitlist capable of a flow a few percent lower than the entered duty point. It is recommended to allow an undersize of 10 percent to avoid unilateral overdimensioning. Note! Once the Flow and Discharge Pressure values have been entered, the `Start sizing' button is activated and it is possible to get a recommendation.

Control mode Select the control mode that is most suitable for your selected type of installation. By default, CAPS has selected the control mode most often used for the selected type of installation, but the user can always select another control mode. The available control modes are defined by the input, the user has made earlier in the wizard, so it is not possible to select a control mode that cannot be used for the selected type of installation. The user can also decide if a frequency converter should be included and if it should be integrated or external.

Page 82: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Load Profile An important feature in CAPS Sizing is the ability to provide an accurate calculation of energy consumption based on a given load profile.

CAPS lets you select between different load profiles; the `Standard profile' is a heating pump profile, while the `Full load' profile sees the pump always operating at a fixed duty point. You can also define your own load profile by selecting `User profile' and edit the values in the input fields.

Page 83: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Configuration At this step you define you define the configuration of your system.

In `Dimensions according to Standard', you can define if you want the sizing process to take a specific dimensioning standard into account. If you choose DIN 1988 rules such as reserve flow, maximum number of starts per hour, flow velocity etc. are taken into account. At `Total number of pumps' you can set a specific number of pumps or allow CAPS to select the best solution within a set range of pumps e.g. 1-4 in accordance with the selected evaluation criteria such as price or energy consumption or both. After selecting the number of pumps you want to size for, you can also enter a number of standby pumps if any. If a tank is required on the discharge side, then mark the checkbox. CAPS can either calculate the membrane tank size or you can enter the tank size manually. If applicable you can enter the size of an existing tank in the discharge pipe. You can the percentage value of the difference between the start and stop pressure by the ON/OFF band question. This is the bandwidth in which the installation will switch on and off to avoid constant starting and stopping of the installation. At the `Velocity limitation' question, you can decide if flow velocity changes should be taken into account. At the `Preferred products' question, you can decide if you want to size for booster sets or for pumps.

Operational conditions

Page 84: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

At this step, the user can set the operational conditions for the pump including frequency, phase, power supply and voltage. CAPS will take these conditions into account when a reaching a sizing result.

Hit list settings At this step, the user can set hit list settings for the outcome of the sizing process. This is also the last step before the sizing result reached.

Page 85: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Limit search to..: This gives the user the option of pre-setting the outcome of the sizing process based on the inputs made previously in the sizing process. Include particular pump in hitlist: This gives the user the option of pre-selecting a specific pump to be included in the hitlist. This can be useful for comparing a known pump with the sizing result. Max. hits per product group: Set the number of hits allowed per product group Max. hits total: Set the total number of hits wanted in the hit list. Evaluation criterion: The order of the results after pressing the `Start sizing' button depends on the "Evaluation Criterion" settings. By default this setting will be set to `Price + energy costs', but it is also possible to order the results in the hit list by `energy consumption' alone. Energy price: Set the energy price used to order the sizing results in the hit list Calculation period: Set the number of years used in the Life Cycle Cost calculation

Grundfos recommends This is the result of the sizing wizard's calculations.

The left column in the window shows an input overview detailing the inputs entered at the different steps in the wizard. The right column of the window (below Grundfos recommends) shows the recommended pump followed by the quotation text describing the pump

Page 86: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Sizing – Industrial Applications General The sizing tool is where Grundfos utilizes its long experience in pump design and application knowledge. This results in a very comprehensive, yet easy to use program that is almost always able to produce a suitable pump for your application. The sizing tool is divided in 8 main application area's that are again subdivided in sub application areas. Depending on which market or country CAPS is used, applications and sub applications can vary. Each application comes with its own specific question catalogue.

An important feature of these question catalogues is the possibility to quickly select a pump using only basic input concerning Head and Flow, make advanced calculations with regard to energy consumption, payback periods, load profiles, cost of ownership etc.

The Sizing Wizard, a quick tour

The Sizing Wizard basics

A sizing wizard is a guide intended to help the user narrow down and find the right product for his needs. The wizard contains a number of steps with each step consisting of questions relating to the application you wish to size a pump for. Adjust the values and settings to suit your preferences or simply enter your required Flow and Head values and start the sizing. However, some input fields are interdependent, so we recommend you to follow the order suggested in the program. Use the ‘Next’ and ‘Back’ buttons to navigate between the steps in the wizard. Click the ‘Start sizing’ button. Calculations will be carried out on the basis of your input. After a few seconds, a list of relevant pump solutions is displayed at the bottom of the screen, ranked in order of relevance. You can then access further details by double clicking your preferred pump solution.

Page 87: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Click the button

Some of the input fields have a button next to them.

When you click the button, a sub-window will appear, allowing you to enter additional input or perform a calculation. Entering extra input here will ensure even more accurate and detailed sizing calculations and printout data.

Saving and loading Settings in Sizing

All the input that you make in a wizard, such as head, flow, a load profile, etc. can be saved using the “Save as” button . These settings can be reloaded again using the “Open” button.

Default settings

CAPS allows you to set and save your own default settings within each sizing wizard. When you mark the ‘Use as default sizing input’ in the ‘Save sizing input’ dialogue, all your input in the sizing wizard, except for Flow and Head, will be reloaded the next time, you enter the sizing wizard.

Industrial Applications

Page 88: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

For many years Grundfos has been one of the major pump suppliers to industrial OEM's or industrial end users. The wide range, reliability and versatility make Grundfos the ideal pump for industrial purposes.

Select type of Installation

The first step of the Industrial Applications sizing wizard concerns the type of installation. Select the type of installation by either clicking once on one of the illustrations and then clicking the Next button or simply by double-clicking on the illustration of the preferred type of installation.

Select subapplication

At this step of the Industrial applications wizard, you select the type of sub-application. These vary depending on the type of installation, you selected at the previous step.

Page 89: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Your Requirements

At this step, the very basic values used in the sizing process must be entered, flow and head. With these values, CAPS now has all the information needed to present you with a list of pumps matching your requirements.

Calculators

The industrial applications sizing wizard contains a calculator to provide you with a easy-to-use tool for determining the pipe friction losses. Click on the calculator to the right of the pipe friction losses input field.

Page 90: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

To calculate the pipe friction losses in the pipes, enter the data for the pipes. Enter the pipe length, select pipe material and pipe size. If you want to change the pipe diameter, just add a pipe 2, 3, 4, 5, 6 or 7 and enter the characteristics of that particular pipe At the bottom of the window you also get a suggestion for a recommended pipe diameter based on the calculation of the flow velocity. The roughness of the pipe is based on your selection of pipe material. You can calculate the losses from single resistances in your system outside the pit by using the calculator in the Zeta column. Enter the number of single-resistance losses in your pipe system inside the pit in this window:

When all the calculations are made, go back to the Your requirements-window. The Start sizing-button will now be active, and you can go straight to the sizing result by clicking this button.

Pump Design

At the pump design step, you select the types of pump design applicable to your application as well as pump material and connection type.

Control Mode

Select the control mode that is most suitable for your selected type of installation. By default, CAPS has selected the control mode most often used for the selected type of installation, but the user can always select another

Page 91: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

control mode. The available control modes are defined by the input, the user has made earlier in the wizard, so it is not possible to select a control mode that cannot be used for the selected type of installation. The user can also decide if a frequency converter should be included and if it should be integrated or external.

Configuration

At the configuration step, you can specify how many pumps and standby pumps you need to get the required flow. Please note that if more than one pump is required, the result of the sizing calculation will contain pumps of the same type.

Electrical Data

Page 92: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

At this step, the user can set the operational conditions for the pump including frequency, phase, power supply and voltage. CAPS will take these conditions into account when a reaching a sizing result.

Hitlist Settings

Here you can choose a specific pump to be included in the hit list. If you do so, you can compare an evaluation of the system using this pump against the best hit. Here you also select evaluation criterion for your hit list and limit the search to a specific pump type.

If you wish to make a calculation of life cycle costs, enter the basic data concerning energy price, calculation period and the pumps operating hours.

Page 93: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Grundfos recommends

Here is the result of the sizing wizard’s calculations

The left column in the window shows an input overview detailing the inputs entered at the different steps in the wizard. The right column of the window (below Grundfos recommends) shows the recommended pump followed by the quotation text describing the pump. You can open a product detail window for the recommended product and see more detailed information by clicking the product number link below the Input overview window. You can also click on ‘Alternatives’ to see other products that fulfill the input made during the sizing process.

Page 94: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Sizing - Renewable Energy (WinCAPS only)

The description of this extremely sophisticated solar and wind energy calculation program can be found under the menu option: Help/Sizing Manuals/SQ Flex A printed version of this manual can be found in the menu option: Help/Manuals in Print Format/SQ Flex

Page 95: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Life Cycle Cost Calculations Life cycle cost analyses are useful in many situations and they can be of great help when you want to: - analyze the life cycle cost of the selected pump - choose a new pump solution - estimate whether or not it would be profitable to replace and old pump system - have documentation to support your decision. A life cycle cost analysis provides an estimate of the total cost of owning and operating a pump system. It covers the initial investment and operating costs, giving a much more accurate picture of the actual cost involved. All calculations and input is based according to the standards of Europump and the United States Hydraulic Institute. More information on these calculations can be found on these websites: www.europump.org www.hydraulicinstitute.com Recommended literature on this subject is the publication Pump Life Cycle Costs, published by and available from these two organizations.

Calculation in five steps Preparing a Life Cycle Cost analysis involves five steps. Note that you must follow the order of the five steps: 1. What to compare First, you indicate what you want to compare. You have up to five options: - no comparison - comparison with a pump in the hit list - comparison with a non-regulated pump (Heating & Air-Conditioning sizing only) - comparison with an existing pump - comparison with a pump in the hit list and an existing pump. 2. Level of detail You can select the level of detail you want in your Life Cycle Cost analysis. You may want simple or complete calculations, or perhaps you just want to compare energy consumption rates. In a simple analysis, Grundfos has pre-selected the most relevant parameters for you. In a complete calculation, all the parameters of the standardized LCC analysis are included. 3. General input At this stage, input is given for parameters, which are common for all pumps to be compared. This concerns inflation rate and interest rate.

Page 96: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

4. Specific input You can now begin to enter specific LCC input for the pump systems to be compared. You can leave input fields blank if they are not relevant in your particular case. However the red dot by the `Pump System' input field indicates that this is a required input. The user must enter a value here to complete the Life Cycle Costs calculation.

5. Calculation Click the `Next' button. After a few seconds, you will receive the results.

That's it. Five simple steps and you have a complete Life Cycle Cost analysis.

How does the calculation work ? First the Initial investment costs are evaluated, which are the pump price plus additional investment costs; added to this are the Installation and commissioning costs. These costs all occur only at the start of the pump life cycle Then the program evaluates the energy consumption (which is P1) and multiplies this with the operating hours per year, the energy prices and the Life in Years to come to the "Energy Cost". These energy costs are corrected for inflation rate and interest rate Added are the other yearly costs like:

Maintenance cost

Downtime and loss of production cost

Page 97: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Environmental cost At the end of the Life in Years (Pump Life Cycle) period the Net Present Value of the Decommissioning and Disposal Costs are calculated, corrected for inflation and interest rate. The point of this exercise is to prove that the initial investments are actually peanuts if the whole picture is evaluated and especially energy consumption is a major part. Also the program makes an evaluation of saving that can be achieved against an existing or an alternative solution.

The Inflation Rate The inflation rate will actually increase the Net Present Life Cycle Cost value because it assumes that all costs will increase with this percentage per year.

The Interest Rate This rate will decrease the Life Cycle Cost value because you can park your money that you have to pay in the years of the lifecycle on the bank against this rate.

Note 1: The Inflation and Interest Rate are working opposite e.g. an inflation rate of 3% and an interest rate of 3% will eliminate each other and the outcome of the calculation of the Life Cycle Cost will be the same as if in both fields nothing was filled in.

Note 2: Operating hours per year

It would be expected that if the pump operates for instance 10 hours per day and 360 days per year, the yearly operating hours would be 3600. However WinCAPS makes an intelligent evaluation of the requested dimensioning flow and the actual calculated flow and will adjust the number of operating hours accordingly. So with a higher actual flow, the number of operating hours will be decreased to come to the requested yearly cubic meters.

Where can I see the result of the Life Cycle Costs calculation? After completing a Life Cycle Costs calculation, you can make a print-out containing a table and a graphical representation of the result. Click the print icon and select the `Life Cycle Cost report - graphics' and `Life Cycle Cost report - table' options in the Print/Preview dialogue.

Page 98: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Click the `Preview/Export' button to see the print-out: The `Life Cycle Cost report - graphics' print-out

Page 99: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

The `Life Cycle Cost report - table' print-out:

After a Life Cycle Cost calculation is completion, the result of the Life Cycle Cost analysis can also be seen in the `Life Cycle Cost'-tab. Simply click on the product in the hit list and then click on the tab to get both a graphical representation of the result as well the table containing the calculated results.

Page 100: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Additional sizing options Sizing Summary print The Sizing summary print option is a new feature in CAPS. This printout contains the most important input and sizing results using graphics and colour to provide an immediate overview of the results of the sizing calculation. In many cases this is all the documentation you need.

Sizing of NK pumps according to ISO 5199 When selecting an NK pump, the motor size is calculated with a safety margin according to ISO 5199. The motor size is decided by calculating the P2 at the duty point and then choose the required motor from the table. Check your technical literature for the specific details of this table.

Page 101: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Service General From version 7.5 the service information has been greatly enhanced, offering interactive exploded views and sectional drawings for most Grundfos products. The level of information can differ, depending on whether you are a Grundfos service engineer, dealer or end-user.

Accessing Service Information You can access service information for a particular product in two ways

Click on the button "Service" in the top main button bar. This will open a tree structure menu with all product lines of which there is service information available. Simply click on one of these product lines until you can select a product number from the hit list in the bottom of the screen.

After selecting a product in the catalogue or sizing part, you can click on the button "Service details" to get access to service information for this particular product number. If the button is grayed out, no information is available.

Page 102: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Layout of the Service Window The service window has the following layout and functions

You select the product number using the hit list

Select here whether you want to access the list for Service Parts or the Parts list. The display of product numbers depends on your version and country settings

You can either click in the list on the left hand side, or click on a position number in the drawing to highlight a particular part number. A left mouse-click anywhere else in the drawing will zoom the drawing in, a right hand mouse-click will zoom out.

Additional information concerning your selection is displayed in the yellow box in the drawing.

You can select the Exploded View or the Sectional Drawing to be displayed

Page 103: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Additional PDF files concerning service, assembly and dismantling can be accessed using the button "Service Instruction".

Printing Service Information When you are in the service window, you can print the available information using the little print icon in the bottom right hand corner or using the menu File/Print-Export. The following dialog box will appear

Here you can specify which information you want to print and which format and detail level you want to use. Using the "List Layout" button, a new window will become available (see below) where you can further specify the amount of information that will appear on your prints.

Page 104: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Notice that you can only print this information when you are in the Service Window!

Page 105: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Projects (WinCAPS only) General You can save your selections and quotations in the projects part of the program. In this part you can enter your project header and customer details and your own company data. By default WinCAPS takes the company data that you entered in the "Options" menu, but this can be overwritten. In the Options menu, you define in which directory your project should be stored.

Adding a selection to a project Whether you are in Catalogue, Sizing or Replacement, you can always add a product to a project. Simply highlight the selected product in the result grid and push the button "Add to Project" in the bottom right hand corner. If there no project open, WinCAPS will automatically start a new project and add your selection to position 1, if there is already a project open, WinCAPS will add your selected pump to this project and asks you to which position number you want to add your selection. If your selection contains accessories, these will also be included. You can check the status of your project by pressing the button "View Project". You return to the Catalogue, Sizing or Replacement area by pressing the corresponding buttons on top of the screen.

Editing your Project There are several ways of which you can edit a project. To do this, first go to the project screen, either by pressing the "Project" button on top of the screen or the "View Project" button in the lower right hand corner.

Changing the unit price and quantity Highlight the product which price you want to change and press the "Edit" button in the middle of the page. A new screen will appear where you can change the quantity and single price.

Changing the quotation text of your product

Quotation Edit Dialog Box

Highlight the product which price you want to change and press the "Edit" button in the middle of the page. Press the "Edit quotation text" button. The text that would normally come with the selected product will now appear. This text can now be edited or if you wish deleted and with the normal Windows copying and pasting (with the Ctrl C and Ctrl V buttons) insert your own text. All the above changes will be saved if you save your project.

Page 106: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Replacement General The replacement section is divided in several sections, which are accessible by the drop down list on top of the screen

Central heating and hot water circulation pumps CAPS contains a comprehensive replacement list for central heating circulating and hot water pumps. You will access this list by pressing the "Replacement" on the top of the screen. After selecting the manufacturer of the pump you want to select, you can make a pre-selection by typing in a type-designation, pipe connection or by built in length Depending on local availability, distance pieces are also included if the existing pump has a longer built-in length then the new pump. Should there be special conditions to be taken into account with replacement, these are displayed when pressing the "Information" button in the left hand bottom corner.

Grundfos CR replacement program CAPS includes a comprehensive replacement program in which the old Grundfos CR series can be replaced by the new CR models. Just follow these simple steps: * Select the type of CR pump you want to replace. Include the flow for reference purposes * Select a pump from the list of old CR pumps that are applicable for these conditions * After clicking on one of these particular pumps, the hit list will appear with suitable replacements * Clicking on the "i" will pop up a screen with relevant replacement information

Page 107: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Double-clicking in the hit list will show the graph with the pump curve of the old pump compared to the one of the new pump. Your requested flow is displayed on the old pump curve.

Old and new pump curve in 1 graph

Grundfos is continuously updating the replacement program with new pump series and new competitors

Page 108: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Selecting Accessories General CAPS comes with a range of standard accessories that can be selected either with a pump or separate. A distinction is made between electrical and mechanical accessories. All Grundfos pump controls and accessories to those controls are in the electrical section while flanges, couplings, pipes, tanks etc are in the mechanical part. If you want to select accessories with a pump, first choose your pump in Catalogue or Sizing. Click on the "Accessory" button in the bottom left hand corner and the accessories for your selected pump series become available, including (when available) drawings, instruction manuals, photo's etc. After selecting an accessory, the details will be displayed on the right hand side of the screen, while the pump details will still be visible on the left. If you want to select an accessory without selecting a pump first, you can only do this from the Catalogue area. When going into the Catalogue area, there will be a book in the bookshelf that contains the accessories. From this book you can make your selections.

Page 109: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

Working with Glycol solutions and solutions other than water General CAPS offers the possibility to adapt the pump curve and the power consumption according to the kinematical viscosity and density of the pumped fluid in relation to the temperature of the fluid. In the Catalogue you can simulate the fluid by pressing on the calculator button in the "Curve settings" menu. The steepness of the curve will change and where the power of the installed motor is insufficient, the curve will be dotted.

Extensive possibilities for Glycol type selection.

In sizing, there is the possibility in the "Advanced" sections of Heating and Air-conditioning to select glycol in the "Pumped Liquid" field, allowing input for type, concentration, temperature etc. After entering the new data in the fields Viscosity and Density, CAPS will calculate the new pump curve and power consumption. Important. This new data might lead to a selection of a bigger pump than if you would select a pump using Heating water as a medium. The reason is that CAPS detects that the installed motor of the original selection (using Heating water) will not cover the entire curve anymore if you use glycol and will select a standard pump with a bigger motor, e.g. 15 kW instead of 11 kW).

Important: While the above is technically correct, in practice often the smaller pump is preferred but with an oversized motor. In this way the better duty point is combined with the ability to cover the entire curve and often a smaller pipe connection will suffice.

The reason that CAPS chooses the bigger pump solution is because the program does not (yet) contain any data of standard pumps with oversized motors. If glycol is selected with a minimum liquid temperature under 0 C, CAPS automatically searches for a pump with the correct seal. (this function depends on local availability of pump types with the correct shaft seal).

Page 110: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

When changing the density and viscosity, CAPS also still display the original pumpcurve in the background and indicate when the motor is overloaded

Working with Non Newtonian Liquids The calculations for different viscosities in CAPS are based on Newtonian liquids and cannot be used for non-Newtonian liquids. Grundfos should be contacted in case you want to pump solutions that fall under that category Non-Newtonian liquids are liquids with a nonlinear relationship between shear rate and shear stress. This means that the viscosity is not constant but will change with head and flow rate. The behaviour of non-Newtonian liquids will not only change with head and flow, but will also be different for different types of liquid. Examples of non-Newtonian liquids are: Paper pulp, grease/oil, soap and paint.

Antifreeze/Secondary fluids for heat transfer included In WinCAPS 7.43 new medias were introduced to ease the use of CAPS when working with antifreeze or secondary fluids. The list of fluids is constantly expanded; check your CAPS version for the current list In connection with the implementation of the new fluids, new functionality has been added to both the Catalogue and the Sizing part of CAPS.

Medium selection in the Catalogue When a pump is selected and the "Curve Settings" button is clicked, a calculator button appears beside the input fields for Viscosity and Density. If the button is used, a dialogue box appears, where you can select a liquid from the dropdown list and, depending of which media you have selected, input your concentration and Liquid Temperature during operation. When this is selected, CAPS automatically calculates the Viscosity and Density for you. The calculation of density and viscosity based on concentration is supported by Department of Mechanical Engineering, Energy Section, Technical University of Denmark.

Page 111: A Guide To Using WinCAPS 2008 - plummediaserver.complummediaserver.com/grejanje.com/grundfos/wincaps_manual.pdf · Grundfos has developed the CAPS software, so customers and professionals

NOTE:

If an Antifreeze media is chosen in Catalogue, it is not checked whether or not the pump is suitable for the media. This feature is only applied in the Sizing part of CAPS.

If you select a "Liquid temperature during operation" that is below the minimum temperature that your concentration of the media would allow, CAPS input "zeros" in both Viscosity and Density thus making it impossible to calculate a new curve with the not allowed values. The limitation for Viscosity is 1-300 mm/s while for Density they are 700-1500 kg/m. Inputting numbers that result in values outside these limitations will provoke an error message and stop a corrected curve from being calculated and shown.

NOTE:

Some pumps are allowed to appear in the hit list even though they do not fulfill all the rules above. These are pumps where you can easily change the shaft seal to a suitable type for the fluid. When ever such a pump appears, the sizing result will contain a yellow frame with a warning that request the user to change the shaft seal - and contact Grundfos.