A-1...8" split face block metal panel to match existing ... service addition existing building 10' x...
Transcript of A-1...8" split face block metal panel to match existing ... service addition existing building 10' x...
![Page 1: A-1...8" split face block metal panel to match existing ... service addition existing building 10' x 10' oh (typ.) dryvit to match existing dryvit honda blue a-mega panel anod. alum.](https://reader033.fdocuments.net/reader033/viewer/2022042204/5ea642fbee28a8761017d53a/html5/thumbnails/1.jpg)
![Page 2: A-1...8" split face block metal panel to match existing ... service addition existing building 10' x 10' oh (typ.) dryvit to match existing dryvit honda blue a-mega panel anod. alum.](https://reader033.fdocuments.net/reader033/viewer/2022042204/5ea642fbee28a8761017d53a/html5/thumbnails/2.jpg)
![Page 3: A-1...8" split face block metal panel to match existing ... service addition existing building 10' x 10' oh (typ.) dryvit to match existing dryvit honda blue a-mega panel anod. alum.](https://reader033.fdocuments.net/reader033/viewer/2022042204/5ea642fbee28a8761017d53a/html5/thumbnails/3.jpg)
319
.03'
647.15'
254.22'
DETENTION BASIN
EXISTING BUILDING EXISTING BUILDING
TRA
NS
IT R
D. (
120
.00
WID
E)
65.0
0'
CB
175.00'
75.33'
32.0
0'
90
.0'
30
.0'
54.0"
PROPOSEDADDITION
PROPOSEDADDITION
EXISTINGBUILDING
EXISTINGBUILDING8
9
10
16
21
21
23
6
47
22
16
14
14
16
16
27
10
10
12
FF=658.50
FF=658.51
FF=658.50
FF=657.65
18.3'
647.15'
323.0
2'
20'16'20'16'
70.0'
16'
3
2
Lia
F.F. ±0'-0"
27'-0"
16'-0"
20'-0"
30'-0"
TOP OF WALL+18'-0"
PROPOSED NEWSERVICE ADDITION
EXISTING BUILDING
METAL PANEL TO MATCH EXISTING8" SPLIT FACE BLOCK
TOP OF WALL+16'-8"
F.F. ±0'-0"
27'-0"
16'-0"
20'-0"
30'-0"
PROPOSED NEWSERVICE ADDITION
EXISTING BUILDINGEXISTING BUILDING PROPOSED NEWSERVICE ADDITION
PROPOSED NEWSERVICE ADDITION
EXISTING BUILDING
PROPOSED NEWSERVICE ADDITION
EXISTING BUILDING
10' x 10' OH (TYP.)
DRYVIT TO MATCH EXISTING
HONDA BLUE A-MEGA PANELDRYVIT ANOD. ALUM. FRAMING W/LOAD GLASS (TYP.)
2'-0"
SPLIT FACE CMU BLOCK
DRYVIT
DRYVIT
8" SPLIT FACE CMU BLOCK ANOD. ALUM. FRAMING W/LOAD GLASS (TYP.)
UP
UP
EXISTINGPROPOSED
stamp:
AS NOTEDscale:
sheet # & title
date:
drawn by:
INDUSTRIAL-COMMERCIAL CONSTRUCTION50 SIMONDS ST., LOCKPORT, NY 14094ph. 716-434-7301 fax 716-434-3553
E. BECKER
DRCC#
THIS DRAWING HAS BEEN PREPARED BY A LICENSED PROFESSIONAL ENGINEERAND SHALL NOT BE REVISED OR ALTEREDIN ANY FORM WHAT SO EVER AFTER THEAPPROPRIATE APPROVAL HAS BEEN AFIXEDHERE ON.
2-9-17
A-1 PROPOSAL
EXISTING BUILDING
![Page 4: A-1...8" split face block metal panel to match existing ... service addition existing building 10' x 10' oh (typ.) dryvit to match existing dryvit honda blue a-mega panel anod. alum.](https://reader033.fdocuments.net/reader033/viewer/2022042204/5ea642fbee28a8761017d53a/html5/thumbnails/4.jpg)
![Page 5: A-1...8" split face block metal panel to match existing ... service addition existing building 10' x 10' oh (typ.) dryvit to match existing dryvit honda blue a-mega panel anod. alum.](https://reader033.fdocuments.net/reader033/viewer/2022042204/5ea642fbee28a8761017d53a/html5/thumbnails/5.jpg)
![Page 6: A-1...8" split face block metal panel to match existing ... service addition existing building 10' x 10' oh (typ.) dryvit to match existing dryvit honda blue a-mega panel anod. alum.](https://reader033.fdocuments.net/reader033/viewer/2022042204/5ea642fbee28a8761017d53a/html5/thumbnails/6.jpg)
G
E
D
JI
J
No Qty
375 Commerce Drive
Amherst, New York 14228
716.691.8080
www.bhsfoodservicesolutions.com
Scale
Project Phase
Date
Drawn by
Checked by
2/7
/2
01
7 3
:3
1:0
4 P
M
Preliminary
10750 Main St.
Clarence, NY
02 FEBRUARY 17
RFH
Checker
No. Description Date
APPROVAL PRINT
As Noted
FSE-1