94 Analysis of Vibrational Dampers
-
Upload
jaime-arellano-huerta -
Category
Documents
-
view
220 -
download
0
Transcript of 94 Analysis of Vibrational Dampers
-
7/30/2019 94 Analysis of Vibrational Dampers
1/24
ANALYSIS OF VIBRATIONAL DAMPERS FOR TRANSMISSION
LINES VIA SCATTERING THEORY
Technical Note Submitted to IEEE Transactions on Power Systems
August 19, 1994
Dr. Jacob S. Glower, Member ASME, IEEE
Department of Electrical Engineering
North Dakota State University, Fargo, North Dakota 58105
Abstract
In this paper, the problem of adding damping to a vibrating string is considered. Instead of
using feedback control or frequency domain techniques, a wave-analysis approach proposed
by von-Flotow for beams and trusses is used. This technique is based upon the premise that
resonances are caused by waves reflecting off of discontinuities. By eliminating the
reflections, the resonances will dissappear. The purpose of the controller is therefore to
minimize reflections.
This paradigm is used to analyze two different controllers commonly used to dampen
vicrations in high-voltage transmission lines: a mass damper tied to an absolute reference
similar to "winglets" and a mass damper similar to a Stockbridge damper. Using scattering
theory, it is shown that both designs can be effective at minimizing reflections of traveling
waves ad thereby minimize oscillations. Further, this analyzsis approach gives good insight as
to why each controller works and what the effect of varying different parameters will be -
features which are often lacking in other design and analysis approaches. Hence, the wave
analysis approach of von Flotow appears to be highly appropriate to the analysis of such
controllers.
1
-
7/30/2019 94 Analysis of Vibrational Dampers
2/24
Introduction
A large number of systems have lightly damped modes that are undesirable. Such systems range
from long bridges during an earthquake to tall buildings swaying in the breeze to lightweight robotic
arms that flex when rapidly slewed to high-voltage transmission lines which vibrate in the wind. In all
these cases, a better system could be obtained if the resonances could be reduced. The objective of
a controller for each of these systems is likewise the same: reduce the resonance.
While the objective for the controller in each case may be similar, the approach used to design the
controller often varies considerably. Often times, the approach used is dictated by the point of view
taken to model the system.
One modeling approach uses modern control techniques along with a state-space formulation (Balas
1979, Joshi 1989). With this approach, the differential equation describing the system is expressed in
terms of an infinite-series whose elements consist of eigenvectors and eigenvalues - often referred to
as mode shapes and modal frequencies. The resonances results in the poles of the system being
lightly damped. The objective of the controller is then to increase the damping of these poles.
An implicit assumption behind using a state-space formulation is that some form of state-feedback
will be used to control the system. Those who take this design approach likewise use similar
controller structures with the gains computed using different algorithms ranging from LQR techniques
(Lim, 1992), root locus techniques (Maghami 1992, Yang 1992), inverse plant and sliding-modes
(Watkins 1992, Yurkovich 1990), and others. This approach is extremely popular and has been
2
-
7/30/2019 94 Analysis of Vibrational Dampers
3/24
used on trusses (Watkins, 1992), beams (Ferri, 1992), simulations of space structures, (Balas 1978,
Lim 1992), one-link (Kotnik, 1986) and multilink robotic arms (Yurkovich 1992, Xu 1992).
While these approaches all work well in simulations, they often have problems when implemented
(Lim, 1992). One explanation for this may be the modelling errors introduced by using a finite-order
state-space model of the system rather than the infinite-order model. Gibson (1980) demonstrated
that this alone will destabilize any feedback control law that does not use collocated feedback unless
the system has natural damping. Another possible explanation could be the sensitivity of the model
and likewise the controllers based upon them. Since lightly damped structures often are time-varying
(as the load changes) or are uncertain, this sensitivity may be a problem (Desanghre 1986, Joshi
1989). The design of a controller than is robust to model uncertainty has likewise come into
prominence recently.
A second approach for modeling an oscillatory system is to look at the transfer function from the
applied force to the resulting displacement - termed the input impedance (Snowdon, 1968). Using
this point of view, resonances result in the impedance becoming large. The design of a controller,
therefore, should be to reduce the amplitude of the input impedance.
Ormondroyd (1928) first used this notion to design a mass damper for a flexible beam. By tuning the
mass and spring to the first resonance of the beam, the resonance could be shifted to a higher
frequency. The natural damping of the beam at higher frequencies would then reduce the impedance
at this resonance and likewise reduce the resonance. Brock (1946) extended this work by adding a
3
-
7/30/2019 94 Analysis of Vibrational Dampers
4/24
damping to the mass damper and showing how the damper could be tuned to minimize the
impedance of the shifted resonance. Snowdon (1968) followed this by showing how several mass
dampers could be used to dampen several resonances. These techniques have been used to design
dampers for flag poles, power lines, and tall buildings with some degree of success (Hunt 1972).
Unfortunately, these controllers are often difficult to tune and often are not as effective as predicted
(Iwuchukwu 1985). Some adaptive techniques to automatically tune these controllers has likewise
been proposed (Desahghre, 1986).
A third approach as proposed by von Flotow takes an entirely different point of view towards the
cause of (and hence control of) resonances. To understand this point of view, consider the following
thought study:
First, consider an system which extends to infinity such as a large pond or an infinite string. Such a
system would have no resonances since any initial conditions would disappear as the energy radiates
out to infinity similar to ripples in a pond.
Next, suppose that you wanted to create a resonance. To do this, you must prevent the energy from
radiating out to infinity - i.e. the energy must be confined somehow. To confine the energy, some
method of reflecting it back into the region when it gets too far away is required. Since reflections are
caused by discontinuities in the medium, this means that you must surround a region with a
discontinuity. This is analogous to replacing the pond with a glass of water - the waves now reflect
off the edges back into the glass, containing the energy and creating resonances.
4
-
7/30/2019 94 Analysis of Vibrational Dampers
5/24
Finally, suppose that you had a resonance that you wanted to eliminate. The prior line of reasoning
suggests that the resonances exist due to discontinuities surrounding confining the energy. This implies
that: 1) The controller that tries to minimize the resonances should attack the cause of the problem:
the discontinuities, and 2) The controller should be located at or near the point where the
discontinuities are created. Ideally, the controller should make one discontinuity disappear so that,
relative to the system, you have an system that extends to infinity and has no resonances.
This paradigm was first hinted at by Vaughan (1968), who proposed an infinite-order controller for a
beam in bending that acts as an infinite beam, thus eliminating all reflections. von Flotow (1983) took
this idea and developed wave analysis technique for large truss networks, similar to space platforms.
Von Flotow (1986a) then used the wave technique to define joints so that waves could be channeled
to certain members of a truss. Energy absorbing sections could then be added as an energy "kill
zone"
Further extension of wave analysis techniques to beams with shear and bending moments was
presented in (1986b) and (1986c). In (1986b), von Flotow found the endpoint contrtaints necessary
to absorb all energy at the end of a hanging Timeshinko beam. Since medium is dispersive, control
was frequency dependent. The "best" viscous damper then found using least squares ofer a specified
frequency range. Further, the scattering matrix had to be approximated sine it was 4x4 including both
incident and reflected bending and shear waves.
5
-
7/30/2019 94 Analysis of Vibrational Dampers
6/24
Results very similar to existing controllers based upon modal analysis such as proposed by Balas
(1979). Point is that better understanding of how and why controllers work is obtained since the
control is attacking the cause of resonances, not just the effect. New insight into different controllers
now possible, such as ones which shunt energy away (von flotow 1986c) or absorb energy in certain
frequencies possible.
Complexity of wave analysis for trusses and beams due to bending and sheer creating 4th-order
dynamics. Further, beams and trusses are dispersive in nature, which results in
frequency-dempendent controllers.
Such in NOT the cast for strings under tension, however: 2nd-order dynamics lending themselves
well to 2x2 scattering matricies and are non-dispersive in nature. Likewise, the wave analysis point
of view should be easier to apply to strings and have simpler results.
This paper looks at applying von-Flotow's approach to problems with damping vibrations in strings.
Two different cases are investigated:
First, the controller is assumed to be attached to the earth and apply a force to the string. This
is similar to the design of winglets for high-voltage transmission lines or terminating a
high-tension cable.
6
-
7/30/2019 94 Analysis of Vibrational Dampers
7/24
Second, a mass-damper is assumed for the controller where no earth reference is permitted.
This is similar to the design of Stockbridge dampers for high-voltage transmission lines to
dampen vibrations.
By using a paradigm based upon traveling wave analysis, potential and problems with each approach
ahould be more clear than with other approaches. The merits of using an analysis and design
paradigm as proposed by von Flotow for such problems will then be more obvious.
Notation
Term: Definition
m The mass of the mass damper
w The frequency of the oscillations in the incident wave
c The wave velocity of the string
T The tension in the string
p The density of the string
M the mass damper's mass
B The damping in the mass damper
K The spring stiffness in the mass damper
Introduction
Consider first the problem of designing a mass damper type of controller for a vibrating string when the
controller is attached to a fixed reference as per Figure 1. Such a problem is encountered when
designing "winglets" for damping vibrations in high-voltage transmission lines. These winglets are pieces
of metal or plastic which are placed along the span of a line. The mass of the winglet would then
7
-
7/30/2019 94 Analysis of Vibrational Dampers
8/24
correspond to m while the wind resistance generates some resistance to motion, B. In practice, K is
zero since attaching a spring to a fixed reference (such as a tower) is not done. Conceptually, however,
such a spring could be added. For analysis purposes, therefore, the general case of K not equal to zero
will be analyzed.
The purpose of the control design is then to choose m, B, and K to minimize the oscillations in the
string. Using the paradigm of von Flotow, this is equivalent to choosing these terms to minimize the
reflection/transmission terms, which is equivalent to maximizing the energy dissipation.
Since vibrating strings are linear systems and the objective is to maximize energy dissipation, the system
presented in Figure 1 can be similified somewhat. Beacuse the system is linear, the "optimal" controller
for a general wave will also be "optimal" when two identical waves are traveling to the right for x0. This symmetry allows a controller to be designed for only 1/2 of the string as presented in
Figure 2.
The advantage of analyzing the 1/2 string is that the string's displacement for x
-
7/30/2019 94 Analysis of Vibrational Dampers
9/24
First, an infinite string is considered. A sinusoidal wave traveling left to right is assumed for the
exciting signal. The amplitude and phase of the reflected wave will then be determined using a
force balance at x=0.
Second, the "optimal" values for M, B, and K will be determined by minimizing the reflection with
respect to each.
Last, the implications of this "optimal" choice with respect to the design of "winglets" will be
assessed by looking at the controller's sensitivity to changes in frequency and in the paremeters M,
B, and K.
Derivation
Assume without loss of generality that a sinusoidal waveform excites the string of the form
(1)g(x, t) = cos (cx t) + cos(cx + t
or, using phasor notation,
(2)g(x, t) = ej( cxt) + ej( cx+t
Here, it is assumed that a wave is traveling right with an amplitude of 1.00 and a frequency of w. Upon
encountering the discontinuity at x=0, it is reflected back tothe left with a reflection coefficient of .The amplitude of relates to the amplitude of the reflection while the angle of determines the phase
lag of the reflection.
In order to determine , a force balance is used at x=0 is used. From Figure 3, the net force at x=0 is
9
-
7/30/2019 94 Analysis of Vibrational Dampers
10/24
(3) F= 0 = Tdgdx
+ md y
dt2
+Bdy
dt+ K
where the subscript gxand y
tdenotes differentiation with respect to x and t respectively. Substituting for
g, evaluating at x=0, and simplifying results in
(4)0 = K m2 +j(T/c +B) ejt+ K m2 +j(T/c B)
An implicit assumption behind using phasors is that one will take the real part eveltually. Beacuse of
this, the e-jwt term can be converted to a ejwt term using the relationship
(5)Re((a +jb)ejt) =Re((a jb)ejt).
With this, (4) can be rewritten as
(6)0 = K m2 +j(T/c +B) + K m2 j(T/c B)
Solving for results in
(7) =Km 2j(T/cB)
Km
2+k(T/c+B)
.
Next, in order to minimize the reflections, the amplitude of needs to be minimized:
(8) 2 =Km
2
2
+(T/cB)2
(Km) 2+(T/c+B)2
To find the optimal choice of M, B, and K, the partials of with respect to each are set to zero:
(9) 2
m = 0 = (4BT/c)2
2
K m
2
(10) 2
K= 0 = (4BT
2/cK m
2
10
-
7/30/2019 94 Analysis of Vibrational Dampers
11/24
(11) 2
B= 0 =
K m
2
2
+ (T/c B)2
(2B)(T/c +B)
From (9) and (10), several solutions exist. Most of these solutions are not of interest, however, for
practical considerations. The solution of T=0 implies no tension on the string. This clearly will not work
for high-voltage transmission lines since some tension is necessary to keep the lines off the ground. The
solution w=0 implies a stationary string. This paper assumes motion since it is analyzing vibrating
strings. The solution of 1/c=0 implies infinite wave velcity, onlly possible with zero mass or infinite
tension - both of which are not possible.
The only solution which makes sense is to select . This solution is encouraging since it is them2 =
well-known practice of tuning the resonance of the mass-spring system to the frequency of oscillation.
Assuming that , (11) can be simplified toK m2
=
(12)0 = 3
(B)(T/c)(T/c B)(T/c +B)
The solution B=0 is actually a maximum since it results in =-1. At the frequecny of w, the impedanceof the mass-spring system is infinite. It likewise prevents any motion of the string at x=0 at a frequency
of w. The solution B=-T/c results in an unstable system since the controller adds energy to the system.
The desired solution, therefore, is B=T/c.
Since this analysis was for 1/2 of the string, the optimal choice for selecting M, B, and K is twice the
values previously calculated:
(13)m2 =
B = 2T/c
11
-
7/30/2019 94 Analysis of Vibrational Dampers
12/24
Analysis
Aparently, the selection of M and K are arbitrary so long as they are tuned for eachother. Note,
however, that is a function of frequency as well as M, B, and K. If the frequency of the excitation is
unknown or can vary, then the choice of M and K does affect the effectiveness of the damper. In
Figure 4, the amplitude of is plotted vs. frequency as M varies from 0.01 to 100. Here, the terms M,B, and K are tuned to minimize at w=1 using normalized values for M, B, and K:
(14)mc
T=M0
K= TCM0
B = Tc
so that
(15) 2 =M0
2(1/) 2
M02(1/) 2+
Note from Figure 4 that the range where the mass damper reduces the reflections is drastically reduced
as M increases. The "optimal" choice of a controller, therefore, would be to make the mass as small as
possible (prefereably zero) and tune B to 2T/c.
This is similar to the design of "winglets" for high-voltage transmission lines where small "wings" are
placed on the lines. The wings add damping due to wind resistance as the line moves. The mass of the
winglets are kept small by making them out of sheet metal or plastic. Further, as stated previously, no
springs are attached from the transmission line to the earth or to a tower, resulting in K=0.
It is interesting to note that a competing design for damping vibrations is to place hollow spheres along
the transmission line. These spheres serve to make the line more visable and to dampen vibrations.
12
-
7/30/2019 94 Analysis of Vibrational Dampers
13/24
While the spheres certainly do make the line more visable, they add more mass than the winglets and
provide less wind resistance (due to their aerodynamic shape), and likewise should be less effective at
damping vibrations.
Mass Damper Design
While the addition of winglets appears to be one way of effectively damping vibrations in a transmission
line, other methods exist and are used. One such method is to attach a mass damper to the transmission
line as per figure 5, also termed a stockbridge damper. Here, instead of the controller "pushing" off of a
fixed reference, a spring and damper connect the string to a small mass.
Examples of this form of controller are widespread. In civil engineering, such controllers are termed
harmonic oscillators are are found in skyscrapers to dampen wind-induced oscillations and to mitigate
earthquake damage (Snowdon 1968, Iwuchukwu 1985) as well as support beams for floors where the
objective is to reduce the amplitude of the resonance (Hunt, 1972). In control systems, such a
controller is termed a servo-compensator and is used to force a signal (usually the tracking error) to
zero at the frequency of the disturbance. In high-voltage transmission lines, such controllers are often
called Stockbridge Dampers where they are used to reduce wind-induced oscillations in transmission
lines.
In each case, the objective is the same: minimize the resonance and/or maximize the energy dissipation
by the controller. While the objective may be the same, the analysis techniques vary considerably
ranging from input-impedance methods to pole placement to time responses via finite-element
simulations.
13
-
7/30/2019 94 Analysis of Vibrational Dampers
14/24
Here, the method proposed by von-Flotow for analyzing such a controller from a wave-standpoint will
be used instead. Using this approach, a more intuitive feel for how and why the mass damper works as
well as how to optimize the design is sought.
The method used to optimize M, B, and K will be as before:
First, assuming sinusoidal excitation, the reflection coefficient, , is determined using a force
balance at the end of the string
Second, M, B, and K are "optimized" by setting the partial of reflection with respect to each to
zero
Last, the results are analyzed and interprited to determine why the given solution is "optimal" and to
assess what the effect of varying the control parameters or wave frequency will be.
Derivation
Similar to the previous section, consider only the left-half og the string as presented in Figure 6.
Assume also that a sinusoidal signal excites the string traveling from left-to-right with a reflection
traveling right to left with an amplitude of :
(16)g(x, t) = ej(cxt) + ej(
cx+t)
Referring to Figure 6, the net force at point A is
(17) F= 0 = Tdgdx
B ddt
(g y) K(g y)
while at point B it is
14
-
7/30/2019 94 Analysis of Vibrational Dampers
15/24
(18)md2y
dt2=B d
dt(g y) + K(g y)
Using the "s" operator to denote differentiation with respect to time, the transfer function from g to y can
be found:
(19)y = Bs+K
ms2+Bs+K
g
which can be rewritten as
(20)
(g
y
) =
ms2
ms2+Bs+K
g
Substituting (20) into (17) and simplifying results in
(21)Tmd3g
dxdt2
+ TBd2g
dxdt+ TK
dg
dx+ mB
d3g
dt3
+ mKd2g
dt2
= 0
Substituting in (16) for g and analyzing at x=0 gives
(22)0 = TB
2/c mK2 +jTm
3/c + TK/c + mB3 e
j
+ TB2/c mK2 +j Tm3/c + TK/c mB3
Using (5), the e-jwt term can be converted to a ejwt term allowing (22) to be solved for as
(23) =(TB/cmK)+jTm
2+TK/c+mB 2
(TB/c+mK)+jTm
2
TK/c+mB2
The amplitude of the reflections is likewise
15
-
7/30/2019 94 Analysis of Vibrational Dampers
16/24
(24) 2 =(TB/cmK) 2+Tm
2+TK/c+mB2 2
(TB/c+mK) 2+Tm2TK/c+mB2
2
Setting the partial of with respect to M, B, and K to zero will again allow one to find the "optimal"2
choice of M, B, and K. From the previous solution, it is aparent that the "optinal" choice will resultng
=0. This allows M, B, and K to be determined by inspection.
In order for to be zero, both terms in the numerator of (24) must be zero, resulting in
(25)B = mKcT
(26)K= T2m 2
T2+m 2c
Once again, the mass appears to be arbitrary since Gamma can be set to zero for any positive mass.
One interesting implication of this equation is that quite different designs can be obtained, depending
upon whteher large or small masses are used. Assume first that the mass is arbitrarilly large such as
would be obtained when the spring and damper are tied to the earth. In this case, the numerator of (24)
becomes
(27)0 = (K)2 + T2/c +B2
This gives the prior solutoin of K=0, B=T/c. (Note that this still corresponds to 1/2 of the controller so
the total damping would be twice this.) Here, a spring should not be used. Instead, a relative large
damper tuned to T/c should be used. A design practice could then be to start with K=0, B=0 and
increase B until the reflections are minimized.
16
-
7/30/2019 94 Analysis of Vibrational Dampers
17/24
Assume next that an arbitrarilly small mass is used. This would be exemplified by adding harmonic
oscillators to skyscrapers where the mass of the damper relative to the mass of the structure would be
quite small. In this case, numerator of (24) becomes
(28)0 = TB/c mK
and
(29)0 = Tm2/c + TK/c + mB2
A first order solution for m small is
(30)K m2
B (c/T)(mK) = (c/T)(m2 2 )
This corresponds to the typical design for mass dampers for structures. Here, B is often considered
equal to zero and the mass and spring are tuned to the resonance of the structure. To keep the mass'
displacement finite at resonance, B is then increased from zero. [Snowdon]
In order to determine which solution is superior from a theoretical standpoint, consider first the
sensitivity of to changes in B and K. To determine this, a numerical example corresponding to a
string long made out of 10mm diameter Aluminum with a 5m long traveling wave.
string density = p = 212 g/mTension = T = 500N
wave velocity = c = 48.56 m/s
wave frequency = = 0.5Hz. = rad/sec.
17
-
7/30/2019 94 Analysis of Vibrational Dampers
18/24
In Figure 7, the contour plots for constant Gamma vs B and K are presented for masses between 0.01g
and 1kg. Consider first the contour plot corresponding to a mass of 0.01g. This situation is similar to
the dessign of mass dampers for buildings and other large structures where the mass of the controller is
relatively small compared to that of the structure. In this case, the spring is tuned so that the
mass-spring system has a resonance near the system's resonance
K= 0.09868 0.09870 = m2
A reasonable design procedure for this case would likewise be to set B=0 and then tune K to the
resonance of the structure (equal to frequency of the incident wave in this case). B could then be
increased until the reflected energy is minimized - moving the operating point from the left axis to the
center of the contour plots where Gamma=0. This is in fact the design procedure mentioned by
Iwuchuwu .
In addition to the method for tuning a mass damper, this plot reveals some potential problems with mass
dampers with relatively small masses. Note that the region where Gamma is small is fairly tight: if either
B or K vary from their nominal value by more 10%, Gamma increases from 0 to 0.1. From similar
contour plots, this tollerance becomes even tighter when amaller mass are used. It likewise appears that
tuning a mass damper may be a difficult procedure if small masses are used. As reported in Hunt this is
one of the drawbacks behing using such controllers for large structures: they are notoriously difficult to
tune.
Contrast the first graph to the extreme case of using a Stockbridge damper-like controller with a mass
of 1kg - a not very realistic mass but one that serves to demonstrate the effect of increasing the mass.
18
-
7/30/2019 94 Analysis of Vibrational Dampers
19/24
Note that remains less than 0.1 for K between 0 and 0.2 N/m. This means that if K is tuned
incorrectly by up to 2x high or 0x small, the reflected wave will only increase from 0% of the incident
wave to less than 10%. Note also that B can vary from 0.18 to 0.25 Ns/m with increaseing Gamma
from 0% to 10%.
In figure 8, the effect of varying the frequency of the incident wave on the reflected wave is presented
for various masses. Note from this figure that the reflected wave at 0.5Hz is always zero, implying that
the mass is arbitrary if the exact frequency of the incident wave is known. If the incident wave drifts or
has some bandwidth, however, mass has a pronounced effect. Mass dampers with relatively small
mass have a very narrow frequency range where they are effective. The larger the mass on the mass
damper, however, the wider the range where the mass damper does some good.
A common problem reported with mass dampers is that they are notoriously difficult to tune and are
very sensitive to changes in the structures resonance. With structures, the mass must remain relatively
small due to structural concerns. From the prior analysis based upon von Flotow's wave paradigm, that
this is the case is not at all surprising. Similarly, if a Stockbridge damper is designed with a relatively
small mass, similar problems with tuning the damper of sensitivity to frequency drift should be
encountered. The benefit of increasing the mass on the damper can likewise be observed.
Summary and Conclusions
In this paper, a design approach proposed by von Flotow for controlling beams and trussses was
used to dampen the vibrations of a flexible string: an approach that tries to minimize reflections.
Using this point of view, the objective of the controller was obvious: to minimize the reflections. The
19
-
7/30/2019 94 Analysis of Vibrational Dampers
20/24
location of the controller was clear: given a choice, the controller should be placed where the
reflections are created i.e. at the endpoint. The form of the controller was also clear: some form of
collocated feedback is required since reflections are determined by the constraints at a particular
point on the string.
To illustrate the implications of this design technique, a controller was designed for a vibrating string
under two conditions: first that the controller was attached to the earth and second that the controller
was not (i.e. external forces were zero). It was shown that a very simple and highly effective
controller resulted from this design approach for the first two cases. It was also shown that the third
was more complicated and resulted in a tradeoff between the bandwidth of the controller and the
mass of the damper.
Since this design approach gives simple and effective controllers along with good insight as to why the
controllers work along with their limitations, it is should be considered for any system capable of
being modeled as a string under tension.
References
[1] Balas, M. J., "Direct Velocity Feedback Control of Large Space Structures," Journal of
Guidance and Control, Vol. 2, May-June 1979, pp. 252-253.
[2] Joshi, S.M., 1989, Control of Large Flexible Space Structures, Berlin-Springer Verlag.
[3] Lim, K.B., P.G. Maghami, S.M. Joshi, 1992, "A Comparison of Controller Designs for an
Experimental Flexible Structure," 1992 American Controls Conference, pp. 1343-1352.
20
-
7/30/2019 94 Analysis of Vibrational Dampers
21/24
[4] Maghami, P.G., S. Gupta, S.M. Joshi, 1992, "Design of Low-Authority Controllers Using an
Eigensystem Assignment Technique," 1992 American Controls Conference, pp. 2780-2783.
[5] Yang, B., 1992, "Noncolocated Control of a Damped String Using Time Delay," 1992
American Controls Conference, pp. 2445-2488.
[6] Watkins, J., Yurkovich. S., 1992, "Vibration Control for Slewing Flexible Structures," 1992
American Controls Conference, pp. 2525-2529.
[7] Yurkovich, S., A. Tzes, K. Hillsley, 1990, "Controlling Flexible Links Rotating in the Horizontal
Plane," The 1990 AmericanControls Conference.
[8] Ferri, A.A., Bindmann, A.C., 1992, "Damping and Vibration of Beams with Various Types of
Frictional Support Conditions," Journal of Vibrations and Acoustics, pp. 289-296.
[9] Kotnik, P., S. Yurkovich, U. Ozguner, 1986, "Acceleration Feedback for Control of a Flexible
Arm," Journal of Robotic Systems, pp. 181-196.
[10] Yurkovich, S., E. Garcia-Benitez, J. Watkins, 1992, "Feedback Linearization with Acceleration
Feedback for a Two-Link Flexible Manipulator", The 1992 American Controls Conference, pp.
1360-1365.
[11] Xu, Jian-Xin, M. Boesch, U. Ozguner, 1992, "Variable Structure Control of Rigid-Flexible
Closed-Chain Systems," The 1992 AmericanControls Conference, pp 1903-1908,
21
-
7/30/2019 94 Analysis of Vibrational Dampers
22/24
[12] Gibson, J. S., 1980, "A Note on Stabillization of Finite Dimensional Linear Oscillators by
Compact Linear Feedback," SIMA Journal of Control and Optimization, pp. 311-316.
[13] Desanghre, Geert and Vansevenant, Eddy, 1986, Adaptive Tuned Vibration Absorber,
Proceedings of the International Modal Conference - IMAX vol 2, Publ by Union College, Graduate
and Continuing Studies, Schectady, NY p.1347-1352.
[14] Snowdon, J.C., 1968, Vibration and Shock in Damped Mechanical Systems, John Wiley &
Sons, Inc.
[15] J. Ormondroyd and J.P. Den Hartog, 1928, "The Theory of the Dynamic Vibration Absorber,"
ASME Journal of Applied Mechanics, Vol 49, pp A9-A22.
[16] J.E. Brock, 1946, "A Note on the Damped Vibration Absorber," ASME Journal of Applied
Mechanics, Vol 68, p. A248.
[17] Hunt, J.B., 1972, Dynamic Vibration Absorbers, Mechanical Engineering Publications, Ltd.,
London.
[18] Iwuchukwu, Michael Bubem, 1985, Seismic Effects of TMD on Higher Modes, Masters
Thesis, North Dakota State University.
[19] Vaughan, D.R., "Application of Distributed Parameter Concepts to Dynamic Analysis and
Control of bending Vibrations, Journal of Basic Engineering, June 1968, pp. 157-166.
[20] von Flotow, A. H., "A Traveling Wave Approach to the Dynamic Analysis of Large Structures,"
Proceedings of the AIAA Strictures, Dynamics, and Materials Conference, South Lake Tahoe,
CA, May 2-4, 1983.
22
-
7/30/2019 94 Analysis of Vibrational Dampers
23/24
[21] von Flotow, A. H., Disturbance Propogation in Structural Networks," Journal of Sound and
Vibrations, 1986a.
[22] von Flotow, A. H., and Schafer, B., "Wave Absorbing Controllers for a Flexible Beam,"
Journal of Guidance, Control, and Dynamics, 1986b.
[23] von Flotow, A. H., "Traveling Wave Control for Large Space Structures," Journal of Guidance,
Control, and Dynamics, Vol 9, No. 4, July-Aug 1986c, pp. 462-468.
23
-
7/30/2019 94 Analysis of Vibrational Dampers
24/24
Figure 1: A Mass Damper is Added which Is Able to Generate External Forces to Dampen Vibrations
Figure 2: Using Symmetry, A Controller for 1/2 of the String is Designed
Figure 3: The Forces at the Endpoint of the String
Figure 4: The Effect of Changing Mass on the Reflection, . Note that at the point where the mass
damper is tuned (w=1), the mass is arbitrary. Away from this frequency, smaller masses work better.
Figure 5: Damping Vibrations by Using a Mass Damper Attached to the String
Figure 6: Assuming Symmetry in the Excitating Waves, 1/2 of the String is Analyzed
Figure 7: Contour Plots Showing Constant Reflection Coefficients vs. B and K
Figure 8: The Amplitude of the Reflection vs. Frequency as the Mass Increases
24