8.Anchor Design Methodology(P10-13)

4
C- TECHMAN -2013 © 2013 SIMPSON STRONG-TIE 10 ANCHOR DESIGN METHODOLOGY Adhesive (Bonded) Anchors in Accordance with EOTA Technical Report TR 029 Designer should reference the latest TR029 for a complete description of all variables and calculations 1. Tension Resistance The Design Tension Load, (N Sd ), shall be less than the controlling (lowest) Design Resistance, N Rd = (N Rk /ќ M ), per the following table: Failure Mode Single Anchor Anchor Group Steel N Sd N Rk,s /ќ Ms N h Sd N Rk,s /ќ Ms Combined Pull-out and Concrete Cone N Sd N Rk,p /ќ Mp N h Sd N Rk,p /ќ Mp Concrete Cone N Sd N Rk,c /ќ Mc N g Sd N Rk,c /ќ Mc Concrete Splitting N Sd N Rk,sp /ќ Msp N g Sd N Rk,sp /ќ Msp ќ M = the relevant material partial safety factor given in the product’s ETA A. Steel Resistance, NRk,s (given in the relevant ETA, or calculated based on the steel insert properties) B. Combined Pull-out and Concrete Cone Resistance, NRk,p ,determined as follows: N Rk,p = N 0Rk,p (A p,N /A 0 p,N ) s,Np g,Np ec,Np re,Np N 0 Rk,p = ʋ d h ef ʏ Rk A 0 p,N = influence area of an individual anchor with large spacing and edge distance at the concrete surface, idealizing the concrete cone as a pyramid with a base length equal to scr,Np A p,N = actual area; it is limited by overlapping areas of adjoining anchors (s ч s cr,Np ) as well as by edges of the concrete member (c c cr,Np ) s,Np - takes account of the disturbance of the distribution of stresses in the concrete due to edges of the concrete member g,Np - takes account of the effect of the failure surface for anchor groups ec,Np - takes account of a group effect when different tension loads are acting on the individual anchors of a group re,Np - takes account of the effect of a reinforcement C. Concrete Cone Resistance, NRk,c, determined as follows: NRk,c = N 0 Rk,c (Ac,N/A 0 c,N) s,N re,N ec,N N 0 RK,c = k 1 (f ck,cube ) 0.5 h ef 1.5 k1 = 7.2 for applications in cracked concrete k1 = 10.1 for applications in non-cracked concrete A 0 c,N = influence area of an individual anchor with large spacing and edge distance at the concrete surface, idealizing the concrete cone as a pyramid with a base length equal to scr,N A c,N = actual area; it is limited by overlapping areas of adjoining anchors (s ч s cr,N ) as well as by edges of the concrete member (c c cr,N ) s,N = [0.7 + 0.3(c/c cr,N )] 1; takes account of the disturbance of the distribution of stresses in the concrete due to edges of the concrete member re,N = [0.5 +(hef / 200)] 1; shell spalling factor takes account of the effect of reinforcement ec,N = [1 /(1 + 2eN/scr,N)] 1; takes account of a group effect when different tension loads are acting on the individual anchors of a group, where e N = eccentricity of the resulting tensile load acting on the tensioned anchors D. Splitting resistance due to load, NRk,sp, determined as follows: NRk,sp = N 0 Rk,c (Ac,N/A 0 c,N) s,N re,N ec,N h,sp where N 0 Rk,c ; s,N; re,N; ec,N are determined in part C. above A 0 c,N = influence area of an individual anchor with large spacing and edge distance at the concrete surface, idealizing the concrete cone as a pyramid with a base length equal to s cr,sp A c,N = actual area; it is limited by overlapping areas of adjoining anchors (s ч s cr,sp ) as well as by edges of the concrete member (c c cr,sp ) h,sp = (h/hmin) 2/3 ; factor to account for the influence of the actual member depth, h, on the splitting resistance for anchors according to current experience N Rk is the lesser of: N Rk,s ; N Rk,p ; N Rk,c ; N Rk,sp N Rd = N Rk /ќ M

Transcript of 8.Anchor Design Methodology(P10-13)

Page 1: 8.Anchor Design Methodology(P10-13)

C- T

ECHM

AN -2

013

© 2

013

SIM

PSON

STR

ONG-

TIE

10

ANCHOR DESIGN METHODOLOGY

Adhesive (Bonded) Anchors in Accordance with EOTA Technical Report TR 029 Designer should reference the latest TR029 for a complete description of all variables and calculations

1. Tension Resistance

The Design Tension Load, (NSd), shall be less than the controlling (lowest) Design Resistance, NRd = (NRk/ M), per the following table:

Failure Mode Single Anchor Anchor Group Steel NSd NRk,s / Ms Nh

Sd NRk,s / Ms Combined Pull-out and Concrete Cone NSd NRk,p / Mp Nh

Sd NRk,p / Mp Concrete Cone NSd NRk,c / Mc Ng

Sd NRk,c / Mc

Concrete Splitting NSd NRk,sp / Msp NgSd NRk,sp / Msp

M = the relevant material partial safety factor given in the product’s ETA

A. Steel Resistance, NRk,s (given in the relevant ETA, or calculated based on the steel insert properties)

B. Combined Pull-out and Concrete Cone Resistance, NRk,p ,determined as follows:

NRk,p = N0Rk,p (Ap,N/A0p,N) s,Np g,Np ec,Np re,Np

N0Rk,p = d hef Rk

A0p,N = influence area of an individual anchor with large spacing and edge distance at the concrete surface, idealizing the

concrete cone as a pyramid with a base length equal to scr,Np Ap,N = actual area; it is limited by overlapping areas of adjoining anchors (s scr,Np) as well as by edges of the concrete member (c ccr,Np) s,Np - takes account of the disturbance of the distribution of stresses in the concrete due to edges of the concrete member g,Np - takes account of the effect of the failure surface for anchor groups ec,Np - takes account of a group effect when different tension loads are acting on the individual anchors of a group re,Np - takes account of the effect of a reinforcement

C. Concrete Cone Resistance, NRk,c, determined as follows:

NRk,c = N0Rk,c (Ac,N/A0

c,N) s,N re,N ec,N N0

RK,c = k1 (fck,cube)0.5 hef1.5

k1 = 7.2 for applications in cracked concrete k1 = 10.1 for applications in non-cracked concrete A0

c,N = influence area of an individual anchor with large spacing and edge distance at the concrete surface, idealizing the concrete cone as a pyramid with a base length equal to scr,N Ac,N = actual area; it is limited by overlapping areas of adjoining anchors (s scr,N) as well as by edges of the concrete member (c ccr,N) s,N = [0.7 + 0.3(c/ccr,N)] 1; takes account of the disturbance of the distribution of stresses in the concrete due to edges of the concrete member re,N = [0.5 +(hef / 200)] 1; shell spalling factor takes account of the effect of reinforcement ec,N = [1 /(1 + 2eN/scr,N)] 1; takes account of a group effect when different tension loads are acting on the individual anchors of a group, where eN = eccentricity of the resulting tensile load acting on the tensioned anchors

D. Splitting resistance due to load, NRk,sp, determined as follows:

NRk,sp = N0Rk,c (Ac,N/A0

c,N) s,N re,N ec,N h,sp

where N0Rk,c ; s,N; re,N; ec,N are determined in part C. above

A0c,N = influence area of an individual anchor with large spacing and edge distance at the concrete surface, idealizing the

concrete cone as a pyramid with a base length equal to scr,sp Ac,N = actual area; it is limited by overlapping areas of adjoining anchors (s scr,sp) as well as by edges of the concrete member (c ccr,sp) h,sp = (h/hmin)2/3; factor to account for the influence of the actual member depth, h, on the splitting resistance for anchors according to current experience

NRk is the lesser of: NRk,s; NRk,p; NRk,c; NRk,sp

NRd = NRk/ M

Page 2: 8.Anchor Design Methodology(P10-13)

C- T

ECHM

AN -2

013

© 2

013

SIM

PSON

STR

ONG-

TIE

11

ANCHOR DESIGN METHODOLOGY

2. Shear Resistance

The Design Shear Load, (VSd), shall be less than the controlling (lowest) Design Resistance, VRd = (VRk/ M), per the following table:

Failure Mode Single Anchor Anchor Group Steel Resistance, shear load without lever arm VSd VRk,s / Ms Vh

Sd VRk,s / Ms Steel Resistance, shear load with lever arm VSd VRk,s / Ms Vh

Sd VRk,s / Ms Concrete Pry-out Resistance VSd VRk,cp / Mc Vg

Sd VRk,cp / Mc

Concrete Edge Resistance VSd VRk,c / Mc VgSd VRk,c / Mc

M = the relevant material partial safety factor given in the product’s ETA

A. Steel Resistance, VRk,s (given in the relevant ETA, or calculated based on the steel insert properties)

B. Concrete Pry-out Resistance, VRk,cp, determined as follows:

VRk,cp = k multiplied by the lower of NRk,c and NRk,p k is taken from the relevant ETA report

C. Characteristic Concrete Edge Resistance, VRk,c, determined as follows:

VRk,c = V0Rk,c (Ac,V/A0

c,V) s,V h,V ,V ec,V re,V V0

Rk,c = k1 dnom hefß (fck,cube)0.5c1

1.5 k1 = 1.7 for applications in cracked concrete k1 = 2.4 for applications in non-cracked concrete = 0.1 (lf / c1)0.5 ß = 0.1 (dnom / c1)0.2 A0

c,V = area of concrete cone of an individual anchor at the lateral concrete surface not affected by edges parallel to the assumed loading direction, member thickness or adjacent anchors, assuming the shape of the fracture area as a half pyramid with a height equal to c1 and a base-length of 1.5 c1 and 3 c1 Ac,V = actual area of concrete cone of anchorage at the lateral concrete surface. It is limited by the overlapping concrete cones of adjoining anchors (s 3 c1) as well as by edges parallel to the assumed loading direction (c2 1.5 c1) and by member thickness (h 1.5 c1). s,V = [0.7 + (0.3 c2 /1.5 c1)] 1.0 ; takes account of the disturbance of the distribution of stresses in the concrete due to further edges of the concrete member on the shear resistance h,V = [1.5c1/h]1/2 1.0 ; takes account of the fact that the shear resistance does not decrease proportionally to the member thickness as assumed by the ratio Ac,V/A0

c,V ,V = [1 / [(cos ,V)2 + (sin ,V / 2.5)2]] 1.0 ; takes account of the angle ,V between the load applied, VSd, and the direction perpendicular to the free edge of the concrete member ec,V = [1 / (1 + 2ev / 3c1)] 1.0 ; takes account of a group effect when different shear loads are acting on the individual anchors of a group re,V = 1.0 anchorage in non-cracked concrete and anchorage in cracked concrete without edge reinforcement or stirrups re,V = 1.2 anchorage in cracked concrete with straight edge reinforcement ( Ø12 mm) re,V = 1.4 anchorage in cracked concrete with edge reinforcement and closely spaced stirrups (a 100 mm)

3. Combined Tension & Shear

The following conditions must first be met: ßN 1, where ßN = NSd/NRd AND ßV 1 where ßV = VSd/VRd

For Combined Tension and Shear Loading: ßN + ßV 1.2 (more conservative results) OR

(ßN) + (ßV) 1 (more accurate results)

= 2.0 if NRd and VRd are governed by steel resistance = 1.5 for all other failure modes

VRk is the lesser of VRk,s; VRk,cp; VRk,c VRd = VRk/ M

Page 3: 8.Anchor Design Methodology(P10-13)

C- T

ECHM

AN -2

013

© 2

013

SIM

PSON

STR

ONG-

TIE

12

ANCHOR DESIGN METHODOLOGY

Mechanical Anchors in Accordance with EOTA ETA 001, Annex C Designer should reference the latest ETA 001 for a complete description of all variables and calculations

1. Tension Resistance

The Design Tension Load, (NSd), shall be less than the controlling (lowest) Design Resistance, NRd = (NRk/ M), per the following table:

Failure Mode Single Anchor Anchor Group

Steel NSd NRk,s / Ms NhSd NRk,s / Ms

Pull-out NSd NRk,p / Mp NhSd NRk,p / Mp

Concrete Cone NSd NRk,c / Mc NgSd NRk,c / Mc

Concrete Splitting NSd NRk,sp / Msp NgSd NRk,sp / Msp

M = the relevant material partial safety factor given in the product’s ETA

A. Steel Resistance, NRk,s (given in the relevant ETA)

B. Characteristic Pull-out Resistance, NRk,p (given in the relevant ETA)

C. Concrete Cone Resistance, NRk,c,determined as follows:

NRk,c = N0Rk,c (Ac,N/A0

c,N) s,N re,N ec,N N0

RK,c = k1 (fck,cube)0.5 hef1.5

k1 = 7.2 for applications in cracked concrete k1 = 10.1 for applications in non-cracked concrete A0

c,N = influence area of an individual anchor with large spacing and edge distance at the concrete surface, idealizing the concrete cone as a pyramid with a base length equal to scr,N Ac,N = actual area; it is limited by overlapping areas of adjoining anchors (s scr,N) as well as by edges of the concrete member (c ccr,N) s,N = [0.7 + 0.3(c/ccr,N)] 1; takes account of the disturbance of the distribution of stresses in the concrete due to edges of the concrete member re,N = [0.5 +(hef / 200)] 1; shell spalling factor takes account of the effect of reinforcement ec,N = [1 /(1 + 2eN/scr,N)] 1; takes account of a group effect when different tension loads are acting on the individual anchors of a group, where eN = eccentricity of the resulting tensile load acting on the tensioned anchors

D. Splitting resistance due to load, NRk,sp, determined as follows:

NRk,sp = N0Rk,c (Ac,N/A0

c,N) s,N re,N ec,N h,sp where N0

Rk,c ; s,N; re,N; ec,N are determined in part C. above

A0c,N = influence area of an individual anchor with large spacing and edge distance at the concrete surface, idealizing the

concrete cone as a pyramid with a base length equal to scr,sp Ac,N = actual area; it is limited by overlapping areas of adjoining anchors (s scr,sp) as well as by edges of the concrete member (c ccr,sp) h,sp = (h/hmin)2/3; factor to account for the influence of the actual member depth, h, on the splitting resistance for anchors according to current experience

2. Shear Resistance

The Design Shear Load, (VSd), shall be less than the controlling (lowest) Design Resistance, VRd = (VRk/ M), per the following table:

Failure Mode Single Anchor Anchor Group Steel Resistance, shear load without lever arm VSd VRk,s / Ms Vh

Sd VRk,s / Ms Steel Resistance, shear load with lever arm VSd VRk,s / Ms Vh

Sd VRk,s / Ms Concrete Pry-out Resistance VSd VRk,cp / Mc Vg

Sd VRk,cp / Mc

Concrete Edge Resistance VSd VRk,c / Mc VgSd VRk,c / Mc

M = the relevant material partial safety factor given in the product’s ETA

NRk is the lesser of: NRk,s; NRk,p; NRk,c; NRk,sp

NRd = NRk/ M

Page 4: 8.Anchor Design Methodology(P10-13)

C- T

ECHM

AN -2

013

© 2

013

SIM

PSON

STR

ONG-

TIE

13

ANCHOR DESIGN METHODOLOGY

A. Steel Resistance, VRk,s (given in the relevant ETA, or calculated based on the steel insert properties)

B. Concrete Pry-out Resistance, VRk,cp, determined as follows:

VRk,cp = k NRk,c k is taken from the relevant ETA report

C. Characteristic Concrete Edge Resistance, VRk,c, determined as follows:

VRk,c = V0Rk,c (Ac,V/A0

c,V) s,V h,V ,V ec,V re,V V0

Rk,c = k1 dnom hefß (fck,cube)0.5c1

1.5 k1 = 1.7 for applications in cracked concrete k1 = 2.4 for applications in non-cracked concrete = 0.1 (lf / c1)0.5 ß = 0.1 (dnom / c1)0.2 A0

c,V = area of concrete cone of an individual anchor at the lateral concrete surface not affected by edges parallel to the assumed loading direction, member thickness or adjacent anchors, assuming the shape of the fracture area as a half pyramid with a height equal to c1 and a base-length of 1.5 c1 and 3 c1 Ac,V = actual area of concrete cone of anchorage at the lateral concrete surface. It is limited by the overlapping concrete cones of adjoining anchors (s 3 c1) as well as by edges parallel to the assumed loading direction (c2 1.5 c1) and by member thickness (h 1.5 c1). s,V = [0.7 + (0.3 c2 /1.5 c1)] 1.0 ; takes account of the disturbance of the distribution of stresses in the concrete due to further edges of the concrete member on the shear resistance h,V = [1.5c1/h]1/2 1.0 ; takes account of the fact that the shear resistance does not decrease proportionally to the member thickness as assumed by the ratio Ac,V/A0

c,V ,V = [1 / [(cos ,V)2 + (sin ,V / 2.5)2]] 1.0 ; takes account of the angle V between the load applied, VSd, and the direction perpendicular to the free edge of the concrete member ec,V = [1 / (1 + 2ev / 3c1)] 1.0 ; takes account of a group effect when different shear loads are acting on the individual anchors of a group re,V = 1.0 anchorage in non-cracked concrete and anchorage in cracked concrete without edge reinforcement or stirrups re,V = 1.2 anchorage in cracked concrete with straight edge reinforcement ( Ø12 mm) re,V = 1.4 anchorage in cracked concrete with edge reinforcement and closely spaced stirrups (a 100 mm)

3. Combined Tension & Shear

The following conditions must first be met: ßN 1, where ßN = NSd/NRd AND ßV 1 where ßV = VSd/VRd

For Combined Tension and Shear Loading: ßN + ßV 1.2 (more conservative results) OR

(ßN) + (ßV) 1 (more accurate results)

= 2.0 if NRd and VRd are governed by steel resistance = 1.5 for all other failure modes

VRk is the lesser of VRk,s; VRk,cp; VRk,c VRd = VRk/ M