89.Double-Frequency Buck Converter

3
DOUBLE-FREQUENCY BUCK CONVERTER ABSTRACT Improving the efficiency and dynamics of power converters is a concerned trade off in  power electronics. The increase of switching frequency can improve the dynamics of power converters, but the eff ici ency may be degr aded . The demand of high-p erf ormance power converter is increased dramatically with the broadening of power converter’s application fields. In order to improve the transient and steady state performance of power converters and to enhance power density, high switching frequency is an effective method. However, switching frequency rise causes higher switching losses and greater electromagnetic interference. This, in turn, limit s the inc rease of swi tching fre quen cy and hinder s the improvement of system  performance. Active and passive soft-switching techniques have been introduced to reduce swi tching los ses. A sin gle -pha se boos t-t ype zero-vo lta ge- tra nsi tio n (ZVT) pul se width- mod ula ted converter propos ed in adopts an addi tio nal shunt res onan t networ k to for m an additional Boost cell to realize soft switching of the main switches. However, the auxiliary switches operate in hard switch and high frequency. A double -fr eque ncy (DF) buck conver ter is propos ed to addres s thi s conc ern. Thi s topology consists of a high-frequency buck cell and a low-frequency buck cell; and we call it the “double frequency buck converter” (DF buck).This converter is comprised of two buck cells: one works at high frequency, and another works at low frequency. The high frequency buck cell is use d to enha nce the output performa nce, and the low-fr equency buck cel l to imp rove the conver ter efficie ncy. It operat es in a way that curre nt in the high-fre quency switch is diverted thr ough the low-fr equency swi tch. Thus , the converter can ope rate at ver y hig h fre quen cy without adding extra control circuits. Moreover, the switching loss of the converter remains small. The proposed converter does not need the load transient change information for accurate current control and does not have the current circulating problem. Extension to double-frequency switch-inductor three-terminal network has also been described. The proposed converter exhibits improved steady state and transient responses with low switching loss. An ac small-signal model of the DF buck converter is also given to show that the dynamics of output voltage depends only on the high-frequency buck cell parameters, and is independent of the low-frequency buck cell parameters. Head office: 2 nd floor, Solitaire plaza, beside Image Hospital, Ameerpet, Hyderabad www.kresttechnology.com , E-Mail : [email protected] , Ph: 9885112363 / 040 44433434 1

Transcript of 89.Double-Frequency Buck Converter

Page 1: 89.Double-Frequency Buck Converter

7/29/2019 89.Double-Frequency Buck Converter

http://slidepdf.com/reader/full/89double-frequency-buck-converter 1/2

DOUBLE-FREQUENCY BUCK CONVERTER 

ABSTRACT

Improving the efficiency and dynamics of power converters is a concerned trade off in

 power electronics. The increase of switching frequency can improve the dynamics of power 

converters, but the efficiency may be degraded. The demand of high-performance power 

converter is increased dramatically with the broadening of power converter’s application fields.

In order to improve the transient and steady state performance of power converters and to

enhance power density, high switching frequency is an effective method. However, switching

frequency rise causes higher switching losses and greater electromagnetic interference. This, in

turn, limits the increase of switching frequency and hinders the improvement of system

 performance. Active and passive soft-switching techniques have been introduced to reduce

switching losses. A single-phase boost-type zero-voltage-transition (ZVT) pulse width-modulated converter proposed in adopts an additional shunt resonant network to form an

additional Boost cell to realize soft switching of the main switches. However, the auxiliary

switches operate in hard switch and high frequency.

A double-frequency (DF) buck converter is proposed to address this concern. This

topology consists of a high-frequency buck cell and a low-frequency buck cell; and we call it the

“double frequency buck converter” (DF buck).This converter is comprised of two buck cells: one

works at high frequency, and another works at low frequency. The high frequency buck cell is

used to enhance the output performance, and the low-frequency buck cell to improve the

converter efficiency. It operates in a way that current in the high-frequency switch is diverted

through the low-frequency switch. Thus, the converter can operate at very high frequency

without adding extra control circuits. Moreover, the switching loss of the converter remains

small. The proposed converter does not need the load transient change information for accurate

current control and does not have the current circulating problem. Extension to double-frequency

switch-inductor three-terminal network has also been described.

The proposed converter exhibits improved steady state and transient responses with low

switching loss. An ac small-signal model of the DF buck converter is also given to show that the

dynamics of output voltage depends only on the high-frequency buck cell parameters, and is

independent of the low-frequency buck cell parameters.

Head office: 2nd floor, Solitaire plaza, beside Image Hospital, Ameerpet, Hyderabad

www.kresttechnology.com, E-Mail : [email protected]  , Ph: 9885112363 / 040

44433434

1

Page 2: 89.Double-Frequency Buck Converter

7/29/2019 89.Double-Frequency Buck Converter

http://slidepdf.com/reader/full/89double-frequency-buck-converter 2/2

A current programmed mode (CPM) control circuit is used to control the proposed DF

 buck converter. Simulation and experimental results demonstrate that the proposed converter 

greatly improves the efficiency and exhibits nearly the same dynamics as the conventional high-

frequency buck converter. Furthermore, the proposed topology can be extended to other dc–dc

converters by the DF switch-inductor three-terminal network structure.