Submittal Guide
iO SeriesIntelligent fire alarm solutions for small buildings
Seewhats
possible
now.
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
2/50
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
3/50
Project: ___________________________
Contact: ___________________________
Date: ___________________________
Thankyou for giving us the opportunity to provide this submittal for an iO
Series Life Safety System. iO Series combines analog addressable detection
with technologically advanced sensor diagnostic capabilities. Together these
innovations offer unsurpassed stability, reliability, and flexibility.
This guide provides a summary of these innovations and includes a
comprehensive presentation of related system components and devices.
Products we are submitting for your consideration are indicated by a
checkmark in the margins of the pages that follow.
More detailed information can be found in individual data sheets dedicated
to each product. All these sheets, along with guide specifications and other
useful product information, are available electronically on our LifeLines
CD-ROM. This exhaustive collection of life safety related literature is fully
searchable.
Thank you for giving us the opportunity to provide this submittal. Please do
not hesitate to contact us should you require further information.
_____________________________
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
4/50
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
5/50iii
Submittal Guide
iO SeriesIntelligent fire alarm solutions for small buildings
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
6/50
iO Series Submittal Guide
Intelligent fire alarm solutions for small buildings
2013 UTC Fire & Security Americas Corporation, Inc.
All rights reserved. Specifications subject to change without notice.
Edwards is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation.
1016 Corporate Park Drive, Mebane, NC 27302
85005-0132, Issue 2
Wiring diagrams provided herein are for information and reference only and are not to be used for installation pur-
poses. Consult the appropriate installation documents for wiring and configuration details.
This guidebook is for information only and is not intended as a substitute for verbatim legislated requirements. For
authoritative specifications regarding the application of life safety, security, and access control systems, consult
current editions of applicable codes and standards. For authoritative interpretation of those codes and standards,
consult your local authority having jurisdiction.
While every effort has been made to ensure the accuracy and completeness of this guidebook, the authors and
publishers assume no responsibility for errors, inaccuracies, omissions, or any inconsistencies herein.
EST, Genesis Series, and Signature Series are trademarks of UTC Fire & Security Americas Corporation, Inc.
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
7/50
Intelligent Analog Initiating Devices 11Combination CO/Fire Detectors ......................................12
Fire Detectors .................................................................13
Duct Smoke Detectors ................................................... 13
Detector Bases .............................................................. 14
Detector Accessories .....................................................15
Input/Output Modules .................................................... 16
Pull Stations ...................................................................22
Notification Appliances 23
Wall Strobes, Horns & Chimes ........................................ 25
Wall Speakers and Speaker-strobes ...............................26
Ceiling Speakers, Horns, and Strobes ............................27
Outdoor Speakers and Speaker-Strobes ........................28
Outdoor Horns and Horn-Strobes .................................. 29
Audio Notification System...............................................30
Firefighters Telephones ............... ............... ................ .... 31
Harsh Environment Signals .............................................32
Audible Signals ...............................................................33
Accessories ....................................................................34
Hazardous Location Devices 35
Initiating Devices.............................................................36
Notification Appliances ................................................... 37
Door Holders & Relays 38
Door Holders ..................................................................38
Relays ............................................................................39
SPDT Relays ..................................................................39
iO Series Analog 1System Specifications ......................................................2
Control Panels ..................................................................3
Option Cards ....................................................................4
Power Supplies ................................................................6
Remote annunciation .......................................................8
Accessories ....................................................................10
v
With control panels, devices, and accessories all
engineered to work in unison, iO Series systems
provide reliable performance and the advanced
features you need for successful installation and
worry-free operation. Best of all, iO Series leaves
you in control not hemmed in by a limited product
line. ESTs extensive range of fire alarm products
gives you the freedom to tailor each system to the
particular needs of the building and the budget
of the building owner while a robust feature set
leaves plenty of room for upgrades, expansions,
and retrofits long into the future.
But innovative features tell only part of the
story: when you specify iO Series youre getting
more than outstanding value in a fire alarm panel;
youre benefitting from a whole family of control,
detection, and notification appliances finely tuned
to work together engineered and tested to func-
tion as a single unified system.
Built on the successes of the past, and meet-
ing the needs of the future, iO Series is the chang-
ing face of small building fire detection today.
Cohesive,comprehensive
analog addressable
fire alarm for small
buildings.
iO SeriesLife Safety Systems
http://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/4%20--%20Hazardous%20Location%20Devices/4%20--%20Hazardous%20Location%20Devices.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/4%20--%20Hazardous%20Location%20Devices/4%20--%20Hazardous%20Location%20Devices.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/5%20--%20Door%20Holders%20&%20Relays,%20Index/5%20--%20Door%20Holders%20&%20Relays,%20Index.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/5%20--%20Door%20Holders%20&%20Relays,%20Index/5%20--%20Door%20Holders%20&%20Relays,%20Index.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/5%20--%20Door%20Holders%20&%20Relays,%20Index/5%20--%20Door%20Holders%20&%20Relays,%20Index.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/1%20--%20iO%20Analog%20Control/1%20--%20iO%20Analog%20Control.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/1%20--%20iO%20Analog%20Control/1%20--%20iO%20Analog%20Control.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/1%20--%20iO%20Analog%20Control/1%20--%20iO%20Analog%20Control.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/1%20--%20iO%20Analog%20Control/1%20--%20iO%20Analog%20Control.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/1%20--%20iO%20Analog%20Control/1%20--%20iO%20Analog%20Control.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/1%20--%20iO%20Analog%20Control/1%20--%20iO%20Analog%20Control.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/1%20--%20iO%20Analog%20Control/1%20--%20iO%20Analog%20Control.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/1%20--%20iO%20Analog%20Control/1%20--%20iO%20Analog%20Control.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/1%20--%20iO%20Analog%20Control/1%20--%20iO%20Analog%20Control.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/1%20--%20iO%20Analog%20Control/1%20--%20iO%20Analog%20Control.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/1%20--%20iO%20Analog%20Control/1%20--%20iO%20Analog%20Control.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/1%20--%20iO%20Analog%20Control/1%20--%20iO%20Analog%20Control.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/5%20--%20Door%20Holders%20&%20Relays,%20Index/5%20--%20Door%20Holders%20&%20Relays,%20Index.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/5%20--%20Door%20Holders%20&%20Relays,%20Index/5%20--%20Door%20Holders%20&%20Relays,%20Index.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/5%20--%20Door%20Holders%20&%20Relays,%20Index/5%20--%20Door%20Holders%20&%20Relays,%20Index.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/4%20--%20Hazardous%20Location%20Devices/4%20--%20Hazardous%20Location%20Devices.pdfhttp://stora/MyLibrary/MyDocuments/EST/Submittal%20Guides/85005-0132%20--%20Small%20Analog%20Submittal%20Guide/4%20--%20Hazardous%20Location%20Devices/4%20--%20Hazardous%20Location%20Devices.pdf -
8/11/2019 85005-0132 -- IO Series Submittal Guide
8/50
D e t e c t i o n & A l a r m S i n c e 1 8 7 2 .
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
9/501
iO SeriesIntelligent Control
iO Series life safety systems are a powerful intelligent solu-tion for small to mid-sized buildings. Advanced analog tech-
nology delivers the benefits of flexible system installation,
while a clean and easy-to-operatate user interface makes
panel operation and system maintenance quick and intuitive.
The smart choice
Signature Series electronic addressing eliminates the tedium
of setting dipswitches, and automatic device mapping en-
sures that each device resides on the system at its correct
location. Meanwhile, innovative programming features allow
the system designer to customize powerful built-in features
to precisely suit the needs of
the building owner.
Flexibility built right in
Two fully-programmable front
panel switch/LED combi-
nations provide an added
measure of flexibility. Their
slide-in labels take the mystery
out of custom applications,
and present a clean finished
appearance.
Perfect for retrofitsiO Series is particularly well-
suited to retrofit applications.
All connections are made over
standard wiring no shielded
cable required. This means
that in most situations existing
wiring can be used to upgrade
a legacy control panel to iO
Series technology without the
expense or disruption of rewir-
ing the entire building.
Signals with a differenceiO Series NACs are configurable to fully support the ad-
vanced signaling technology of Edwards Genesis and En-
hanced Integrity notification appliances. These devices offer
precision synchronization of strobes to UL 1971 standards.
For Genesis devices, enabling this feature allows connected
horns to be silenced while strobes on the same two-wire
circuit continue to flash until the panel is reset.
Clear-cut remote annunciation
Remote annunciation is a strong suit of the iO64. Up to eight
annunciators can be installed on a single system. Compat-
ible annunciators include a range
of LED and LCD models that
provide zone or point annuncia-
tion, as well as common control
capabilities.
iO Series also supports graphic
annunciation with optional RA
Graphic Annunicator interface
modules. Each interface provides
common control, indicators, and
32 LEDS.
A complete line of accessories
iO Series life safety systems aresupported by a complete line of
intelligent detectors, modules and
related equipment, each of which
is fully tuned and tested to oper-
ate in concert with one another to
provide highly reliable service and
years of trouble-free operation.
iO Series Intelligent Control
Specifications p. 2
Control Panels p. 3
Option Cards p. 4
Power Supplies p. 6
Remote annunciation p. 8
Accessories p. 10
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
10/50
iO Series
Intellige
ntControl
Intelligent Control
2
Ethernet
DACT/Dialer
RS-232
Relays: Two Form C, one Form A
Any combination of up to eight LCD, LED,
and graphic serial annunciators
iO500:4 Class B or 2 Class A NACs
iO64: 2 Class B or 2 optional Class A NACs
iO500:one loop that supports up to 250 intelligent devices.
Can be expanded to two loops. Each loop supports up to 125
detectors and up to 125 modules.
iO64: one loop that supports up to
64 intelligent devices of any type.
Diagram represents an
iO500 system wired for
Class A operation with
a full complement of
option cards.
Upto20,0
00feetofwiringpe
rdataloop!
Specifications
Specifications iO64 iO500
Device loops 1 loop Class B, Class A optional,
supports up to 64 devices
1 loop, expandable to 2, Class A or B,
each loop supports up to 250 devices
Notification appliance
circuits
2 Class B, Class A optional, 2.5 amps
each
4 Class B or 2 Class A, 2.5 amps each
Power supply 3.75 A FWR total at 120/230 VAC 60
Hz
3.0 A FWR total at 230 VAC 50 Hz
0.5 amps aux power
6.0 A total, 2.5 A max. per circuit at
120/230 VAC 60 Hz. 5.0 A total at
230VAC 50 Hz, 2.5 A max. per circuit
0.5 amps aux power
NAC Operating 24 VDC. NAC minimum voltage: 19.5 VDC @ 20.4 V battery voltage
SLC Loop operating 20 V peak-to-peak
Primary power 120 VAC, 60 Hz, 230 VAC 50-60 Hz
Aux Power 1 Continuous circuit: 24 VDC nominal at 500 mA. A SMK module is required when
using the SIGA-UM module to support two-wire smoke detectors.
Aux Power 2 Resettable circuit: 24 VDC nominal at 500 mA.
Auxiliary output 19 to 25.7 VDC
Base panel current Standby: 155 mA Alarm: 204 mA Standby: 172 mA, Alarm: 267 mA
Battery placement Accommodates up to 10 A/H
batteries. Use external cabinet for
larger batteries.
Accommodates up to 18 A/H batteries.
Use external cabinet for larger batteries.
Batteries Batteries must be sealed lead acid type only. Maximum charging capacity = 26
Ah.
Loop circuit Maximum loop resistance: 66 .
Maximum loop capacitance: 0.7 F.
Style 4, 6, and 7 wiring. 64 isolators
maximum
Maximum loop resistance: 66 .
Maximum loop capacitance: 0.5 F.
Style 4, 6, and 7 wiring. 64 isolators
maximum.
Loop max detector
standby current
1.5 mA (see the UL and ULC compatibility list for your panel
for the maximum quantity of detectors per circuit)
Compatibility ID 100
Alarm contact Form C 24 VDC @ 1 A (resistive load)
Trouble contact Form C 24 VDC @ 1 A (resistive load)
Supervisory contact Form A 24 VDC @ 1 A (resistive load)
Environmental Temperature: 0 to 49C (32 to 120F). Humidity: 0 to 93% RH, noncondensing
Terminal rating All terminals rated for 12 to 18 AWG (0.75 to 2.5 sq mm)
Serial communications Voltage: 2.55 V. Current: 30 mA max
Remote annunciator 8 drops max, RS-485 Class B, Class A
Input zones 16 max. 32 max.
Agency Listing UL, CSFM and ULC
Optional second loop (iO500)
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
11/50
iO SeriesIntelligent ControlSUBMIT
3
Control Panels
iO500 Intelligent Multi-Loop Systems, Data Sheet 85005-0130
iO500G 1 Loop System, 500 analog point capacity, 4 NACs, gray door, surface enclosure, 115VAC, English.
iO500G-2 1 Loop System, 500 analog point capacity, 4 NACs, gray door, surface enclosure, 230VAC, EnglishiO500GC 1 Loop System, 500 analog point capacity, 4 NACs, gray door, surface enclosure, 115VAC, Canadian English
iO500G-F 1 Loop System, 500 analog point capacity, 4 NACs, gray door, surface enclosure, 115VAC, Canadian French
iO500GD 1 Loop System, 500 analog point capacity, two-line dialer, 4 NACs, Gray door, surface enclosure, 115VAC, English.
iO500R 1 Loop System, 500 analog point capacity, 4 NACs, red Door, surface enclosure, 115VAC, English.
iO500R-2 1 Loop System, 500 analog point capacity, 4 NACs, red door, surface enclosure, 230VAC, English
iO500RD 1 Loop System, 500 analog point capacity, two-line dialer, 4 NACs, Red Door, surface enclosure, 115VAC, English.
D16L-iO-2 LED Annunciator Module, 16 groups, 2 LEDs per group. Mounts in cabinet on iO500 systems. Mounts to right of display.
D16L-iO-1 LED Annunciator Module, 16 groups, 2 LEDs per group. Mounts in cabinet on iO500 systems. Mounts to left of display.
SA-TRIM2 Flush mount trim, black
iO64 Intelligent Single Loop Systems, Data Sheet 85005-0131
iO64G 1 Loop System, 64 analog point capacity, 2 Class B NACs, Gray door, surface enclosure, 115VAC, English.
iO64GD 1 Loop System, 64 analog point capacity, 2 Class B NACs, 2 Line Dialer, Gray door, surface enclosure, 115VAC, English.
iO64R 1 Loop System, 64 analog point capacity, 2 Class B NACs, Red Door, surface enclosure, 115VAC, English.
iO64RD 1 Loop System, 64 analog point capacity, 2 Class B NACs, 2 Line Dialer, Red Door, surface enclosure, 115VAC, English.
iO64G-2 1 Loop System, 64 point capacity, 2 Class B NACs, Gray door, surface enclosure, 230VAC, English.
iO64R-2 1 Loop System, 64 point capacity, 2 Class B NACs, Red door, surface enclosure, 230VAC, English.
iO64GL 1 Loop System, 64 point capacity, 2 Class B NACs, Gray door, surface enclosure, 115VAC, English, Canadian.
iO64GL-F 1 Loop System, 64 point capacity, 2 Class B NACs, Gray door, surface enclosure, 115VAC, French, Canadian.
D16L-iO-1 LED Annunciator Module, 16 groups, 2 LEDs per group. Mounts in cabinet on iO500 systems. Mounts to left of display.
SA-TRIM1 Flush mount trim, black
Dimensions
D1
D2 D3
D4
D5
D6
Surface mounting holes
Sem
i-flus
hmoun
ting
ho
les
Surface mounting holes
Panel dimensions, in (cm)
Model D1* D2 D3 D4 D5* D6
iO50028.0
(71.1)
3.85
(9.8)
9.0
(22.8)
22.0
(55.8)
15.75
(40.0)
10.25
(26.0)
iO6421.50
(54.6)
3.85
(9.8)
7.5
(19.0)
15.5
(39.4)
14.25
(36.2)
10.25
(26.0)
* Add 1-1/2 in. (3.81 cm) to D1 and D5 dimensions for trim kit.
Standard FeaturesAll iO Series life safety systems feature an attractive design that
fits with any decor. Its distinctive doorfront offers a contemporary
look thats available with red or silver finishes. All LED indicators
and its large backlit display remain easy to see at all times.
Supports Signature Series intelligent modules and detectors
Form C contacts for alarm and trouble, Form A for supervisory
Electronic addressing with automatic device mapping
Optional Ethernet port for diagnostics, programming and a variety
of reports
Two programmable switches with LEDs and custom labeling
Supports Genesis horn silence over two
wires and UL 1971-compliant strobesynchronization
Supports up to eight serial annunciators,
(LCD, LED-only, and graphic interface).
Can use existing wiring for most retrofit
applications
Upload/download remotely or locally
Two-level maintenance alert reporting
Pre-alarm and alarm verification by point
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
12/50
Intellige
ntControl
SUBMIT
4
iO SeriesIntelligent Control
Option Cards
iO-Series panels are supported by a complete line of modules and related equipment that
enhance performance and extend system capabilities. Option cards are easy to install and set
up. They simply plug directly into the control panel main circuit board or are connected to it
with a ribbon cable. After installation, terminals remain easily accessible for quick connection of
field wiring. The cabinet provides ample room for wire routing, keeping wiring neat and easy to
service at all times.
Class A card installed
on main circuit board
NAC1
NAC2+
NAC2
NAC1+
+ +
+ +
+
+
TB2 on main
circuit board SA-CLA Class A Module
The SA-CLA card provides Class A capability for NAC and annuncia-
tor wiring. Its terminal block provides the wiring connection for NAC
return wiring. The card is required for annunciator Class A wiring even
though this wiring does not return to the SA-CLA card. The SA-CLA
is compatible with iO64 control panels only. iO500 panels are Class
A ready. The SA-CLA is installed directly to the control panel circuit
board using its plastic standoffs and plug connection.
SA-CLA Class A adapter module. Provides Class A capacity on NACs. Mounts in cabinet on main board.
SA-ETH Ethernet Interface CardNetwork cable
Ethernet card
To network
connection
The SA-ETH card provides a standard 10/100 Base T Ethernet network connection
for connecting to an intranet, a local network, or the Internet. The card can be used
to upload and download panel configuration, history, and current status from the
iO-CU to the panel over the network.
The Ethernet card is installed on the plastic assembly and connects to the main
circuit board via a ribbon cable.
SA-ETH Ethernet Port, Slave, for Ethernet connection to local area networks. Mounts in cabinet on base plate.
GND (black wire)
TXD (white wire)
RXD (red wire)
SA-232 RS-232 interface
The SA-232 card provides an RS-232 interface with iO-Series panels. It can be used for
connecting a printer to the control panel to print system events. The card also can be used
for connecting a computer to download a configuration program from the iO-CU to the
control panel.
The RS-232 card is installed on the plastic assembly and connects to the main circuit board
via a ribbon cable.
SA-232 Serial Port (RS-232), for connection to printers & computers, mounts in cabinet to base plate
SA-232 RS-232
interface
SA-CLA Class A
Module
XAL250 Loop Expander Card
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
13/50
SUBMIT
5
iO SeriesIntelligent Control
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
11
11
12
12
16
16
15
15
14
1413
13 9
9
10
103 2 1
3 2 1
++
++
+
+
+
Power in
Power out
SMK
JP1
JP1
Data in
Data out
Terminateor to next
UM
Two-wire smoke
detectors
Two-wire smoke
detectors
Phone line 1
Phone line 2 To wall
phone jack
Phone cables(supplied) RJ31 jacks
SA-DACTwiring
SA-DACT Dialer
The SA-DACT provides communications between the control panel and the central
station over a telephone line system. It transmits system status changes (events)
to a compatible digital alarm communicator receiver over the public switched tele-
phone network. The dialer is capable of single, dual, or split reporting of events to
two different account and telephone numbers. The modem feature of the SA-DACT
can also be used for uploading and downloading panel configuration, history, and
current status to a PC running the iO-CU.
The dialer phone lines connect to connectors on the dialers main circuit board.Phone line 1 connects to connector J4 and phone line 2 connects to connector J1.
SA-DACT Dual Line Dialer/Modem, supports Contact ID, mounts in cabinet on base plate
SMK Smoke Power Converter
The SMK Smoke Power Converter Module provides a backup power source for
two-wire smoke circuits connected to a Signature data circuit. The SMK monitors
the operating power from the power supply. When power begins to degrade, the
SMK provides the necessary operating voltage to the two-wire smoke detection
circuits.
SMK Smoke Power Converter Module
XAL250 Loop Expander Card (iO500 Systems only)
Loop 1 SEC
Loop card
+
Loop 1 PRI+
+ +
Loopdevice
Loopdevice
Data Line
i ii
-
-
- -
i i
i
+ +
Loopdevice
Loopdevice
Data Line
- -
Class B Wiring Class A Wiring
The XAL250 Loop Expander Card provides an additional Signature
Series device loop on the control panel. The card expands the control
panels device capacity to 500 total device addresses, 250 per loop.
The card is compatible with Class B or Class A wiring. It is compatible
with iO500 control panels only. The loop expander card mounts in
the cabinet and connects to connector J7 on the main circuit board.
XAL250 Signature Loop Expansion Module. Adds second loop to iO500 systems, 250 point capacity.
+_
24 VDCauxilliarypower
(not resettable)
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
14/50
Intellige
ntControl
SUBMIT
6
iO SeriesIntelligent Control
Power Supplies
Remote Booster Power SupplyThe Remote Booster Power Supply is a self-contained 24 Vdc power supply designed to
augment fire alarm audible and visual power requirements as well as provide power for
auxiliary, access control and security applications. The booster contains all of the necessary
circuits to monitor and charge batteries, control and supervise four Class B or two Class A
NAC circuits and monitor two controlling inputs from external sources.
Simple switch selection provides a wide variety of operational configurations. Each remote
booster power supply is supplied with its own enclosure providing ample space for additional
interface modules and battery compartment.
When used with Genesis Notification appliances, the booster provides the ability to syn-
chronize strobes as well as horn signals. The booster flexibility allows synchronization with
upstream devices, or, the booster may be used to synchronize downstream devices, as
well as other boosters and their connected devices.BPS notification appliance circuits easily configure for either of two signaling rates: 3-3-3
temporal or continuous. This makes the BPS ideal for applications requiring signaling rates
not available from the main panel. It also allows independent setup of a notification appli-
ance circuit without interfering with the main panel and its initiating circuits. In addition to
the generated signal rates, the BPS can also be configured to follow the signal rate of the
main panels notification appliance circuit. This allows seamless expansion of existing NACs.
For comprehensive configuration and wiring details, refer to the BPS Application Guide,
85001-0582.
BPS6A 6.5 Amp Booster Power Supply Data Sheet 85005-0125
BPS6A/230 6.5 Amp Booster Power Supply (220V) Data Sheet 85005-0125
BPS10A 10 Amp Booster Power Supply Data Sheet 85005-0125
BPS10A/230 10 Amp Booster Power Supply (220V) Data Sheet 85005-0125
3-TAMP Tamper switch Data Sheet 85005-0125
BoosterPower Supply
Sense NAC
Parallel ConnectionThe number of boosters
that can be connectedtogether is limited by wire
run length and available current
BoosterPower Supply
Sense NAC
NAC
Circuit
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
15/50
SUBMIT
7
iO SeriesIntelligent Control
Batteries and Battery Cabinets
12 Volt Batteries 12V4A (4.5 Ah) 12V6A5 (7.2 Ah) 12V10A (11 Ah) Data Sheet 85005-012712V1A2 (1.2 Ah) 12V24A (26 Ah) 12V17A (18 Ah) Data Sheet 85005-0127
6 Volt Batteries 6V8A (8 Ah) 6V10A (12 Ah) Data Sheet 85005-0127Battery Cabinet BC-1 (holds up to two 40 Ah batteries) Data Sheet 85005-0127
Auxiliary Power Supply (APS)
Notificationappliancecircuit (NAC)
Notificationappliancecircuit (NAC)
To next signaling device,booster, or NAC returningto existing control panel
+
+
OUT
OUT
NC
Sense 1
Sense 2
Trouble
COM
COM
COM
IN
IN
NO
NAC1
NAC2
NAC3
NAC4
+
+
+
+
TB2
TB1
TB5200 mA AUX
Continuous Input or signaling circuit
NAC
+
-
AC power failmonitoring
EOL
[3]
The Auxiliary Power Supply (APS) is a self-
contained 24 Vdc power supply designed
to augment fire alarm audible and visual
power requirements as well as provide
auxiliary power for life safety and security
applications. The APS contains all of the
necessary circuits to monitor and charge
batteries, control and supervise four Class
B or two Class A NAC circuits and moni-
tor two controlling inputs from external
sources.
APS6A 6.5 Amp Auxiliary Power Supply Data Sheet 85005-0127APS6A/230 6.5 Amp Auxiliary Power Supply (220V) Data Sheet 85005-0127
APS10A 10 Amp Auxiliary Power Supply Data Sheet 85005-0127APS10A/230 10 Amp Auxiliary Power Supply (220V) Data Sheet 85005-0127
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
16/50
Intellige
ntControl
SUBMIT
8
iO SeriesIntelligent Control
Remote annunciation
Edwards R-Series Annunciators are high-performance remote annunciators that provide
status indication and common controls for
compatible fire alarm control panels, including iO-
Series small analog fire alarm systems. This family
of annunciators offers LCD or LED annunciation.
Models are available with and without common
controls.
Controls Enabled
Ack/Silence
Reset
Signal Silence
Drill
Lamp Test
PowerFireAlarmSupervisoryGround FaultTrouble
RLCD-C
Controls Enabled
Ack/Silence
Lamp Test
PowerFireAlarmSupervisoryGround FaultTrouble
RLCD
l l
il
i l il
ill
i li
ll
l l
il
i l il
ill
i li
ll
l l
il
i li
ll
Controls Enabled
Ack/Silence
Reset
Signal Silence
Drill
Lamp Test
PowerFireAlarmSupervisoryGround FaultTrouble
RLED-C
RLED24
There are three R-Series annunciator models, plus an LED-based
expander. Up to two expanders can be connected to any annun-
ciator. The expander includes 24 pairs of LEDs that extend the
capabilities of any of the annunciators.
All annunciator models include status LEDs and an internal buzzer.
Two models have an LCD text display, and one has 16 pairs of
LEDs for zone annunciation. LCD models feature a large back-lit,
four by twenty character per line, super-twist liquid crystal display.
R-Series annunciators and expanders are mounted on a standard
4-inch square electrical box, using the included mounting ring. They
can also be surface mounted in locking steel enclosures. Three
different enclosures are available.
A keyswitch and graphic annunciator interface is available for R-Series annunciator applications. The keyswitch en-
ables or disables common controls. The graphic annunicator interface cards supports 32 LEDs and 16 switches on
the graphic panel display.
Annunciator
CH2 () OUT
CH2 (+) OUT
CH2 ( ) IN
CH2 (+) IN
CH1 ( ) OUT
CH1 (+) OUT
CH1 ( ) IN
CH1 (+) IN
24V (+) IN
24V ( ) IN
GROUND
24V (+) OUT
24V ( ) OUT
24 VDC +
LISTED 24 VDCSUPPLY
24 VDC
Annunciator
CH2 () OUT
CH2 (+) OUT
CH2 ( ) IN
CH2 (+) IN
CH1 ( ) OUT
CH1 (+) OUT
CH1 ( ) IN
CH1 (+) IN
24V (+) IN
24V ( ) IN
GROUND
24V (+) OUT
24V ( ) OUT
CH2
CH2 +
CH1
CH1 +
FACP
RS-485
I
I
I
I
I
I
I
I
I
I
I
I
I
I I
I
I
I
I
I
I
I
I
I
I
I
I
I
Annunciator
CH2 () OUT
CH2 (+) OUT
CH2 ( ) IN
CH2 (+) IN
CH1 ( ) OUT
CH1 (+) OUT
CH1 ( ) IN
CH1 (+) IN
24V (+) IN
24V ( ) IN
GROUND
24V (+) OUT
24V ( ) OUT
24 VDC +
LISTED 24 VDCSUPPLY
24 VDC
FACP Annunciator
CH2 () OUT
CH2 (+) OUT
CH2 ( ) IN
CH2 (+) IN
CH1 ( ) OUT
CH1 (+) OUT
CH1 ( ) IN
CH1 (+) IN
24V (+) IN
24V ( ) IN
GROUND
24V (+) OUT
24V ( ) OUT
RS-485
CH1 +
CH1
I I
Wiring, Class A Wiring, Class B
RLCD LCD text annunciator without common controls. English. Data Sheet 85005-0128
RLCD-R LCD text annunciator without common controls. English. Red. Data Sheet 85005-0128 RLCDF LCD text annunciator without common controls. French. Data Sheet 85005-0128
RLCD-C LCD text annunciator with common controls. English. Data Sheet 85005-0128
RLCD-CR LCD text annunciator with common controls. English. Red. Data Sheet 85005-0128
RLCD-CF LCD text annunciator with common controls. French. Data Sheet 85005-0128
RLED-C 16-pair LED zone annunciator with common controls. English. Data Sheet 85005-0128
RLED-CR 16-pair LED zone annunciator with common controls. English. Red. Data Sheet 85005-0128
RLED-CF 16-pair LED zone annunciator with common controls. French. Data Sheet 85005-0128
RLED24 24-pair LED zone expander with expander cable and zone card insert. Data Sheet 85005-0128
RLED24R 24-pair LED zone expander with expander cable and zone card insert. Red. Data Sheet 85005-0128
RKEY Remote key switch on plate for enabling or disabling common controls (Lock/Unlock).Data Sheet 85005-0128
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
17/50
SUBMIT
9
iO SeriesIntelligent Control
Annunciator Enclosures
RA-ENC1
RA-ENC2
RA-ENC3
The RA Remote Annunciator Enclosures provide secure, surface mounted protec-
tion for annunciators and extenders. Each consists of a back plate, hinged cover,
and key lock. The enclosures are 16-gauge welded steel with a white, painted
finish. Each enclosure includes a security lock and two keys. The two- and three-
position enclosures have wiring channels for correct routing of interconnections.
The enclosures attach to a standard electrical box, and provide a mounting lip
that takes the place of the integral mounting ring supplied with the annunciators
and expanders.
RA-ENC1 One-position enclosure for Remote Annunciator. Data Sheet 85005-0128
RA-ENC2 Two-position enclosure for Remote Annunciator and one Remote Expander. Data Sheet 85005-0128
RA-ENC3 Three-position enclosure for Remote Annunciator and two Remote Expanders. Data Sheet 85005-0128
Graphic Annunication
24VDC FROM 3-PPS/M
OR 3-BPS/MPOWER RISER
FROM PREVIOUS PANEL
RS-485 NETWORK DATA
POWER MODULE
RS-485 NETWORK DATA
TO NEXT PANEL
24VDCTO NEXT
The GCI series of graphic annunicator drivers allow iO control panels to
display events on an LED-based graphic annunciator. The GCI annun-
ciator card supports 32 LEDs on the graphic panel display. It includes
status LEDs and an internal buzzer. The graphic card is supplied with
snap track mounting. It is attached to a plastic mounting rail that requirestwo EIA panels.
The annunciator communicates with the control panel on the RS 485
data riser, which can be configured for Class A or Class B communica-
tion. The annunciator does not provide ground fault isolation. The driver
card communicates with and is powered by the control panel or by an
approved power supply. Always ensure that National and Local approv-
als and requirements are met when selecting a graphic panel supplier.
GCI Graphic Annunciator Driver Data Sheet 85005-0130
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
18/50
Intellige
ntControl
SUBMIT
10
iO SeriesIntelligent Control
City Tie ModuleAlarm/Supervisory Wiring
Riser out to next deviceor EOL Relay
Riser infromPanel
Data in
Data out
Master Box
MunicipalCircuit
CC1/MCC1
CTMThe City Tie Module provides a simple way of connecting iO
Series to a local energy fire alarm box or City Master Box. One
2-CTM provides either supervisory or alarm signaling. To config-
ure both supervisory and alarm signaling, two City Tie modules
are required.
CTM City Tie Module Data Sheet 85005-0097
Reverse Polarity Module
Provides three reverse polarity transmitters: one for system common alarm; one forsystem common trouble; and, one for system common supervisory.
RPM Reverse Polarity Module Data Sheet 85005-0097
Desktop Serial Printer
The PT-1 series printers are high-speed, nine-pin dot matrix type. It is used to perma-
nently record life safety system changes of state. All printed entries contain the date,
time, event type and a user-defined message for each printed event. The printer is
required in proprietary systems and requires a backup UPS power source. In auxiliary,
local, or remote station systems, the printer is optional.
PT-1S Serial Printer Data Sheet 270020
PT-1S/220 Serial Printer 220/240Vac Data Sheet 270020
Accessories
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
19/5011
iO SeriesI n t e l l i g e n t I n i t i a t i n g D e v i c e s
iO Series Signature Series intelligent analog-addressable system is an entire family of life safety detectors
as well as mounting bases, multiple-function input and output
modules, and user-friendly maintenance
and service tools.
Making the best of true multisensor capa-
bility, Signature Series detectors continu-
ally monitor the protected space with their
on-board sensors, each of which is finely
tuned to detect a different characteristic
of combustion. All this information is
gathered and run through a sophisticated
algorithm that compares the sensor read-
ings over time to known signatures of fires.
Only when a match is found will an alarm
condition occur. This means that a single
multisensor detector can distinguish be-tween a harmless puff of dust and a wisp
of smoke; between hot, humid weather
and a serious life safety condition.
Self-diagnostics and History Log Sig-
nature Series devices constantly run self-checks to provide
important maintenance information. The results of these
checks are automatically updated and permanently stored
in the devices non-volatile memory.
Automatic Device Mapping The Signature Loop Con-
troller learns where each devices serial number address is
installed relative to other devices on the circuit. This map-
ping function is invaluable for tracking down unexpectedor missing device addresses, or finding changes to wiring.
The System Definition Utility program also uses this map-
ping feature to produce system layout or As-Built drawings
showing such details as banch wiring (T-taps), device types
and their addresses.
Fast Stable Communication Built-in intelligence means
less information needs to be sent between the device and
the Signature Loop Controller, making the circuit less sensi-
tive to noise and wire characteristics. This renders shielded
wiring unnecessary. In fact, existing wiring can be used by
Signature Series devices in most retrofit situations.
Testing & Maintenance Each detector automatically iden-
tifies when it is dirty or defective and causes a dirty detectormessage. The detectors sensitivity measurement can also
be transmitted to the loop controller. A sensitivity report may
be printed to satisfy NFPA sensitivity mea surements. The
user-friendly maintenance program shows the current state
of each detector and other pertinent messages. When the
CO sensors electrochemical cell reaches its end of life, the
detector signals a trouble condition to the control panel. The
sensor/daughterboard module is field-replaceable.
Signature Series
Intelligent AnalogInitiating Devices
Combination CO/Fire Detectors p. 12
Fire Detectors p. 13
Duct Smoke Detectors p. 13
Detector Bases p. 14
Detector Accessories p. 15
Input/Output Modules p. 16
Pull Stations p. 22
Loop 1 SEC
Loop card
+
Loop 1 PRI+
+ +
Loopdevice
Loopdevice
Data Line
-
-
- -
i i
i
+ +
Loopdevice
Loopdevice
Data Line
- -
Class B Class A
Circuit specifications
Device loops 1 loop, expandable to 2, Class A or B, each loop
supporting up to 250 device addresses
Com. line voltage Maximum 20 V peek-to-peek
Circuit current 0.5 A max
Circuit impedance 66 total, 0.5 F, max
Isolators 64 maximum
iO Series Signature Device loop
iO Series control panels provide one device
loop circuit that can be used with any mix ofSignature Series detectors and modules. The
iO500 panel can be expanded to provide a
second loop. All loop circuits are supervised
for opens, shorts, and grounds.
Typical Wiring
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
20/50
Devices
SUBMIT
Intellige
ntControl
12
iO SeriesI n t e l l i g e n t I n i t i a t i n g D e v i c e s
Intelligent Carbon Monoxide (CO) Detector
Features the industrys only field-replaceable CO module. The SIGA2-COS detects carbon monoxide from any source
of combustion and analyzes the sensor data to determine when to initiate a CO-related life safety event. SIGA2-COS Intelligent Carbon Monoxide (CO) Detector Data Sheet: 85001-0622
Intelligent Multisensor Photoelectric/Heat Detector with CO Sensor
Includes a photoelectric smoke sensor, a fixed-temperature heat sensor, and a carbon monoxide sensor. The detector
analyzes the smoke and heat sensors independently from the CO sensor, and can report a smoke/fire alarm separate
from a CO-related life safety alarm.
SIGA2-PHCOS Intelligent Multisensor Photoelectric/Heat Detector with CO Sensor Data Sheet: 85001-0621
Intelligent Fixed Temperature Heat Detector with CO Sensor
On-board fixed-temperature heat sensor to detect heat from fire and a field replaceable CO sensor. The detector
analyzes the heat and CO sensors independently, and reports a heat/fire alarm, a CO-related life safely alarm, or both.
SIGA2-HCOS Intelligent Fixed Temperature Heat Detector with CO Sensor Data Sheet: 85001-0620
Intelligent Photoelectric Detector with CO Sensor
Uses a photo-optical sensing chamber to detect smoke, and a field-replaceable CO sensor to detect carbon monoxide.
The detector analyzes the smoke and CO sensors independently to determine whether to initiate smoke/fire alarm, a
CO-related life safely alarm, or both. The two elements can report separately to the system.
SIGA2-PCOS Intelligent Photoelectric Detector with CO Sensor Data Sheet: 85001-0619
Combination CO/Fire DetectorsIn addition to integrated smoke and heat sensors, Signature Series combination life safety
devices include electrochemical carbon dioxide sensors. CO detection has rapidly become
a standard part of life safety strategies everywhere. Monitored CO detection is becoming
mandated with increasing frequency in all types of commercial applications, but particularly
in occupancies such as hotels, rooming houses, dormitories, day care facilities, schools,
hospitals, assisted living facilities, and nursing homes. In fact, more than half of the U.S.
population already lives in states requiring the installation of CO detectors in some com-
mercial occupancies. This is because carbon monoxide is the leading cause of accidental
poisoning deaths in America. Known as the Silent Killer, CO is odorless, tasteless, and
colorless. It claims nearly 500 lives, and results in more than 15,000 hospital visits annually.
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
21/50
SUBMIT
13
iO SeriesI n t e l l i g e n t I n i t i a t i n g D e v i c e s
Fire Detectors
Intelligent Multisensor Photoelectric/Heat DetectorContains a fixed-temperature heat sensor to detect heat from fire and a photoelectric smoke sensor to detect smoke.
Unlike simple multi-criteria detectors, the SIGA2-PHS can report the heat and photo elements as separate event types
or together. This permits the photo element of the detector to report, for example, a supervisory event during the
day, and an alarm event at night while the heat element always reports an alarm.
SIGA2-PHS Intelligent Multisensor Photoelectric/Heat Detector Data Sheet: 85001-0621
SIGA-PHS Intelligent 3D Multisensor Detector, White Data Sheet 85001-0247
Intelligent Photoelectric Detector
The workhorse of modern fire alarm systems, this devices includes a photoelectric smoke sensor to detect smoke.
SIGA2-PS Intelligent Photoelectric Detector Data Sheet: 85001-0619
SIGA-PS Intelligent Photoelectric Detector, legacy housing Data Sheet: 85001-0269
Intelligent Rate-of-rise Heat Detector
Includes a rate-of-rise and a fixed-temperature sensor to detect heat from fire.
SIGA2-HRS Intelligent Rate-of-rise Heat Detector Data Sheet: 85001-0620
SIGA-HRS Intelligent Rate-of-rise Heat Detector, legacy housing Data Sheet 85001-0243
Intelligent Fixed Temperature Heat Detector
Includes a fixed-temperature sensor to detect heat from fire.
SIGA2-HFS Intelligent Fixed Temperature Heat Detector Data Sheet: 85001-0620
SIGA-HFS Intelligent Fixed Temperature Heat Detector, legacy housing Data Sheet 85001-0243
Duct Smoke DetectorsSuperDuct Detectors
Less than two inches deep, SuperDuct intelligent smoke detectors are ideal
for installation in ductwork, where space is always at a premium. Offering
the most advanced and most reliable performance in its class, SuperDuct
represents the perfect balance of practical design and advanced technology.
SuperDuct detectors feature a unique design that speeds installation and
simplifies maintenance. Removable dust filters, conformally coated circuitboards, and optional water-resistant gaskets keep contaminants away
from components, ensuring years of trouble-free service. When cleaning
is required, the assemblies come apart easily and snap back together in
seconds.
Returnair
Duct smokedetector
Supplyair
Duct smokedetector
Remotetest station
FACP
HVACunit
Alarm relay output
Alarm relay output
Remotetest station
SIGA-SD Intelligent SuperDuct Detector Data Sheet: 85001-0584
SD-PH Protective housing for high humidity environments Data Sheet: 85001-0584
Sampling Tubes SD-T8 (8) SD-T18 (18) SD-T24 (24) SD-T36 (36)
SD-T42 (42) SD-T60 (60) SD-T78 (78) SD-T120 (120)
Remote Test Stations SD-TRM (magnetic) SD-TRM (keyed) SIGA-LED (Remote alarm LED)
Accessories SD-GSK (cover gasket kit) SD-MAG (Test magnet kit)
SD-VTK (Air velocity test kit, stoppers only) SIGA-SDPCB (PCB/Signature sensor kit)
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
22/50
Devices
SUBMIT
Intellige
ntControl
14
iO SeriesI n t e l l i g e n t I n i t i a t i n g D e v i c e s
Audible (Sounder) Bases
Signature Series Sounder Bases add an audible
output function to compatible detectors. The Signature Series AB4GT sounder
base, when used with the SIGA-TCDR Temporal Pattern Generator, is compatible
with any Signature Series detector, and is field-configurable for: CO or non-CO
detectors; output tone (steady or temporal); and, for output volume (low or high
dBA). The SIGA-AB4G is compatible with the SIGA-PS detectors only.
SIGA-AB4GT Audible (Sounder) Base for CO and Fire Detectors Data Sheet: 85001-0623
SIGA-TCDR Temporal Pattern Generator for SIGA-AB4GT Data Sheet: 85001-0623
SIGA-AB4G Audible (Sounder) Base for SIGA-PS Detectors Only Data Sheet: 85001-0581
AB4G-SB Surface Box for Audible Bases Data Sheet: 85001-0623
Standard Detector Bases
Standard detector bases provide roomside wiring terminals. They mount to
North American one-gang box, 3 or 4-inch octagon boxes, or 4-inch square
electric box. Bases for 4-inch square boxes include the SIGA-TS4 Trim Skirt to
conceal the electric box and provide a finished appearance.
SIGA-SB SIGA-SB4 (with trim skirt) Standard Detector Base Data Sheet: 85001-0245
Isolator Detector Base
Isolator detector bases provide room-side wiring terminals and includes a built-in
line fault isolator. Models with integral switches allow the detector to be removed
from its base without causing the isolator to operate. Mounts to North American
one-gang box, 3 or 4-inch octagon boxes, or 4-inch square electrical boxes.
Bases for 4-inch square boxes include the SIGA-TS4 Trim Skirt to conceal the
electrical box and provide a finished appearance.
SIGA-IB SIGA-IB4 (with trim skirt) Isolator Detector Base Data Sheet: 85001-0245
Relay Detector Base
This base includes a relay. Normally-open or closed operation is selected during
installation. The dry contact is rated for 1 amp (pilot duty) @ 30 Vdc. The relays
position is supervised to avoid accidentally jarring it out of position. The relay
base does not support the SIGA-LED remote LED. It mounts to North Ameri-
can one-gang boxes, 3 or 4-inch octagon boxes, or 4-inch square electrical
boxes. Bases for 4-inch square boxes include the SIGA-TS4 Trim Skirt to conceal
the electrical box and provide a finished appearance.
SIGA-RB SIGA-RB4 (with trim skirt) Relay Detector Base Data Sheet: 85001-0245
Detector Bases AB4GT AB4GT
SLC +
SLC -
AUX_RISER +
AUX_RISER -
AB4GT AB4GT
TCDR
Listed 24 V
EOL
supervising
equipment
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
23/50
SUBMIT
15
iO SeriesI n t e l l i g e n t I n i t i a t i n g D e v i c e s
SIGA-TCDR Temporal Pattern GeneratorSLC_IN +
AUX_RISER_IN + AUX_RISER_OUT +
A
SLC_OUT +
1 2
From previous device To next device
The SIGA-TCDR Temporal Pattern Generator is an addressable
device that generates sound patterns for carbon monoxide (CO) and fire signals for the
AB4GT sounder base. The control panel sends synchronization and channel commands to
the SIGA-TCDR; the channel selection determines the pattern.
SIGA-TCDR Temporal Pattern Generator for AB4GT Sounder Base Data Sheet: 85001-0623
Detector Mounting Plate
The SIGA-DMP Detector Mounting Plate is a 7-inch (178mm) square mounting plate designed
to provide convenient mounting of Signature Series intelligent smoke detectors in raised floor
or plenum applications. The detector mounting plate may also be installed in low velocity
ducts that have a maximum width of up to 36-inches (915mm) and a maximum height of up
to 36-inches (915mm).
SIGA-DMP Detector Mounting Plate Data Sheet: 85001-0255
Remote LED
The remote LED connects to the SIGA-SB or SIGA-SB4 Standard Base. It features a North
American size one-gang plastic faceplate with a white finish and red alarm LED.
SIGA-LED Remote Alarm LED Data Sheet: 85001-0245
Trim Skirt
Use the SIGA-TS Trim Skirt to give Signature detectors a finished look and hide surface
imperfections around the detectors base. Supplied with all four-inch detector bases, the
SIGA-TS4 can also be ordered separately. Use the black model with SIGA-IPHSB.
SIGA-TS Detector Trim Skirt (white) Data Sheet: 85001-0245
SIGA-TSB Detector Trim Skirt (black) Data Sheet: 85001-0245
SIGA-TS4 Detector Trim Skirt (white) for 4-inch box Data Sheet: 85001-0245
Detector Guard
Constructed of sturdy 16-guage steel, the SIGA-DG Smoke Detector Guard is designed
SIGA-PS smoke detectors from damage or tampering. The advanced louver system allows
smoke detectors to be installed at their listed spacing and has no effect on operating sensitivity.
SIGA-DG Smoke Detector Guard Data Sheet: 85001-0359
SIGA-DGSB Detector Guard Surface Mount Accessory Data Sheet: 85001-0359
Detector Accessories
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
24/50
Devices
SUBMIT
Intellige
ntControl
16
iO SeriesI n t e l l i g e n t I n i t i a t i n g D e v i c e s
Signature Series intelligent
input/output modules feature
multiple user-set personality
codes that define the modules
behavior.
Signature Seriesinput/output modules are extremely flexible andpowerful devices that gather analog information from the slave devices
connected to them and convert this data into digital signals. They are
available in models that mount in standard one- or two-gang electrical
boxes, as well as versions that plug into UIO motherboards.
The actual function of each module is determined by its installer-
selected personality code. This is downloaded to the module from the
Signature Loop Controller during system configuration. Because they are intelligent devices, all decisions are made
at the module. This allows lower communication speed but very fast control panel response time and less sensitivity
to line noise and loop wiring properties. As a result, twisted or shielded wire is not required.
Signature Series
Input/Output Modules
Standard two-gang mount
Plug-in UIOs
with motherboard
Application Module
Waterflow Switches Waterflow/Tamper Module
Class A indicating and initiating circuits,
two-wire smoke detectors
Universal Class A/B
Module
Class B Initiating Circuits:
Door Closers, Fans, Dampers
Class B Input Module
Monitor Module
Control Relay Module
Telephone Power and Audible/Visual Signal
Power Selector, Strobe SynchronizationSignal Module
Sounder Base power Reversal Relay Module
Fire Suppression Releasing Module
Fault detection Isolator Module
Module mounting and installation options
Signature Series input/output modules are available in models that
feature two mounting options: standard mount and plug-in.
Standard mount models are installed to North American two-gang
or one-gang electrical boxes, making them ideal for locations where
only one module is required. Separate I/O and data loop connections
are made to each module.
Plug-in UIO modules mount to UIO moth-
erboards. Two- and six-module UIO
motherboards are available, mak-
ing them ideal for installations
where more than one module is required. Motherboards can
accommodate individual risers for each on-board module,
or shared risers in any combination with their UIO
modules. All wiring connections are made
to terminal blocks on the motherboard.
UIO assemblies may be mounted in either
cabinets, or standard electrical enclosures.
Standard mount
(one- or two-gang)
FIREAL
ARM
MODUL
E
UIO Motherboard
Plug-in (UIO)Module
Cabinet or electrical enclosure
Plug-in UIO
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
25/50
SUBMIT
17
iO SeriesI n t e l l i g e n t I n i t i a t i n g D e v i c e s
Universal Class A/B Module
The Universal Class A/B Module is used to connect initiating, appliance, or two-wire smoke
circuits in either Class A or Class B configurations. The plug-in version can also be used as a
Class A dry contact initiating device circuit. The actual function of this module is determined
by the personality code selected by the installer. Up to fifteen personalities are available.
SIGA-UM Universal Class A/B Module (Two-gang standard mount) Data Sheet: 85001-0275
SIGA-MAB Universal Class A/B UIO (Plug-in) Module Data Sheet: 85001-0275
SIGA-UM
Class B Input Module
The Class B Input Module is used to connect Class B normally-open Alarm, Supervisory, or
Monitor type dry contact initiating device circuits. The standard-mount version is available with
either one or two input connections. The plug-in version accepts two input connections. The
actual function of this module is determined by the personality code selected by the installer.
A total of four personalities are available.
SIGA-CT1 Single Input Module (One-gang standard mount) Data Sheet: 85001-0241
SIGA-CT1HT Single Input Module, high temperature rating (One-gang standard mount) Data Sheet: 85001-0241
SIGA-CT2 Dual Input Module (One-gang standard mount) Data Sheet: 85001-0241
SIGA-MCT2 Dual Input UIO (Plug-in) Module Data Sheet: 85001-0241
SIGA-CT1/CT2
SIGA-MCT2
SIGA-MAB
Synchronization Output Module
The Synchronization Output Module is an intelligent device that connects a supervised output
circuit to a 24 Vdc riser. The output wiring is monitored for open circuits and short circuits.
A short circuit will cause the fire alarm control panel to inhibit the activation of the audible/
visual signal circuit so the riser is not connected to the wiring fault. Upon command from the
Signature loop controller, the Auto-Sync Output Module connects the output circuit to the
riser input. The output circuit operates polarized audible and visual appliances that have an
adjustable resynchronizing feature.
SIGA-CC1S Synchronization Output Module (One-gang standard mount) Data Sheet: 85001-0543SIGA-MCC1S Synchronization Output UIO (Plug-in) Module Data Sheet: 85001-0543
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
26/50
Devices
SUBMIT
Intellige
ntControl
18
iO SeriesI n t e l l i g e n t I n i t i a t i n g D e v i c e s
Signal Module
The Signal Module is used to connect, upon command from the loop controller, supervised
Class B signal or telephone circuits to their respective power inputs. Models are available with
one or two power inputs. These may be either polarized 24 Vdc to operate audible and visual
signal appliances, or 25 and 70VRMS to operate audio evacuation speakers and firefighters
telephones. The actual function of this module is determined by the personality code selected
by the installer. A total of three personalities are available.
SIGA-CC1 Single Input Signal Module (Two-gang standard mount) Data Sheet: 85001-0237
SIGA-MCC1 Single Input Signal UIO (Plug-in) Module Data Sheet: 85001-0237 SIGA-CC2 Dual Input Signal Module (Two-gang standard mount) Data Sheet: 85001-0237
SIGA-MCC2 Dual Input Signal UIO (Plug-in) Module Data Sheet: 85001-0237
SIGA-CC2A Dual Input Signal Module with Class A Operation (Two-gang mount) Data Sheet: 85001-0609
SIGA-MCC2A Dual Input Signal UIO with Class A Operation (Plug-in) Module Data Sheet: 85001-0609
Control Relay Module
The Control Relay Module provides a Form C dry relay contact to control external appliances
such as door closers, fans, dampers etc. This device does not provide supervision of the
state of the relay contact. Instead, the on-board microprocessor ensures that the relay is in
the proper ON/OFF state. Upon command from the loop controller, the relay activates the
normally open or normally-closed contact. This module supports only one personality: no user
configuration is required.
SIGA-CR Control Relay Module (One-gang standard mount) Data Sheet: 85001-0239
SIGA-MCR Control Relay UIO (Plug-in) Module Data Sheet: 85001-0239
Polarity Reversal Relay Module
The Polarity Reversal Relay Module provides a Form C dry relay contact to power and activate a
series of SIGA-AB4 Audible Sounder Bases. Upon command from the Signature loop controller,
the SIGA-CRR reverses the polarity of its 24 Vdc output, thus activating all Sounder Bases on
the data loop. This module supports only one personality: no user configuration is required.
SIGA-CRR Polarity Reversal Relay Module (One-gang standard mount) Data Sheet: 85001-0239
SIGA-MCRR Polarity Reversal Relay UIO (Plug-in) Module Data Sheet: 85001-0239
Riser Monitor Module
The SIGA-RM1 Riser Monitor Module is an intelligent device that monitors the integrity of 24
Vdc, 25 Vac, and 70 Vac circuits, as well as telephone riser signals. Upon the loss of a signal,
the Riser Monitor Module causes the fire alarm control panel to indicate an alert status. Per-
sonality codes downloaded to the Riser Monitor Module during system configuration determine
its function.
SIGA-RM1 Riser Monitor Module (One-gang standard mount) Data Sheet: 85001-0535
SIGA-MRM1 Riser UIO (Plug-in) Module Data Sheet: 85001-0535
Signature Series
Input/Output Modules
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
27/50
SUBMIT
19
iO SeriesI n t e l l i g e n t I n i t i a t i n g D e v i c e s
Input/Output Module
Th e In pu t/ Ou tp ut Modu le is an int el l ig en t devi ce that prov id es th e fo l lo wi ng
modes of operation:
Output with monitor input
Input/programmable output
Input/direct output
SIGA-IO Input/Output Module (One-gang standard mount) Data Sheet: 85001-0533
SIGA-MIO Input/Output UIO (Plug-in) Module Data Sheet: 85001-0533
Waterflow/Tamper Module
The SIGA-WTM Waterflow/Tamper Module is a two circuit intelligent module. Circuit 1 is for Class
B normally-open waterflow alarm switches. When the input contact is closed for approximately 16
seconds, an alarm signal is sent to the loop controller. Circuit 2 is for Class B normally open dry
contact supervisory and tamper switches. When the input contact is closed, an active signal is
sent to the loop controller. Conditions on both circuits are latched at the module.
SIGA-WTM Waterflow/Tamper Module (One-gang standard mount) Data Sheet: 85001-0297
Isolator Module
The SIGA-IM Isolator Module is an intelligent device that allows part of the Signature data loop
to continue operating in the event of a short circuit. The module can be wired into a Class
A data loop at any point. A maximum of 96 isolator modules can be installed on one circuit.
If a fault occurs, the isolator cuts power to all devices beyond the isolator on the loop. Once
activated, the line fault isolator continuously checks the faulted side of the loop to determine
if the short still exists. When the fault is cleared, the module automatically restores the entire
data loop to its normal condition.
SIGA-IM Fault Isolator Module (Two-gang standard mount) Data Sheet: 85001-0271
Monitor Module
The SIGA-MM1 is a single-circuit intelligent module that includes a Class B normally-open dry
contact. This is used for monitoring input from devices such as fans, dampers, and doors.When the input contact is closed, an active signal is sent to the loop controller. The active
condition is not latched at the module.
SIGA-MM1 Monitor Module (One-gang standard mount) Data Sheet: 85001-0297
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
28/50
Devices
SUBMIT
Intellige
ntControl
20
iO SeriesI n t e l l i g e n t I n i t i a t i n g D e v i c e s
Related Equipment
MFC-A Multi-function Cabinet (for UIO and Releasing modules)
27193-11 Surface Mount Box - Red, One-gang
27193-16 Surface Mount Box - White, One-gang
27193-21 Surface Mount Box - Red, Two-gang
27193-26 Surface Mount Box - White, Two-gang
235196P Bi-polar Transient Protector (use with all Signal Modules)
SIGA-MP1 Signature Module Mounting Plate, 1 footprint
SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint
SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint
Riser 2 Inputcommon toall SIGA-UIOModules
Jumpers ConnectRiser Input #1
Between Modules
Individual Riser 1 Input to each SIGA-UIO module
Module Input/Output Wiring
SignatureDataCircuit
Data In
Data Out
Universal Input/Output (UIO) Motherboards
Signature Series Universal Input/Output Module Motherboards provide mounting
and wiring terminations for up to six Signature Series plug-in UIO (SIGA-M se-
ries) modules. UIO motherboards snap into a rigid extruded track (included) with
mounting pads for convenient mounting into a variety of equipment enclosures. UIO
modules plug into the board and are held securely in place with captive machine
screws. All field wiring connects to terminal blocks on the motherboard, which
permits rapid removal and replacement of modules for troubleshooting.
The SIGA-UIO2R provides mounting and wiring terminations for up to two UIOmodules, and the SIGA-UIO6R provides mounting and wiring terminations for up
to six UIO modules. Both motherboards feature a riser #1 input and a riser #2 input
bus. Jumpers on riser #1 input (between modules), facilitate sharing a single riser
among more than one module. This significantly reduces wiring requirements. Re-
moving the jumpers provides
separate riser inputs to each adjacent module. Riser #2 input is
fixed to each module position and cannot be split.
The SIGA-UIO6 provides mounting and wir ing
terminations for up to six UIO modules. This moth-
erboard provides two riser inputs that are common
to all modules.
UIO motherboards mount inside the MFC-A cabinet
or other suitable UL-listed electrical enclosure. EachMFC-A will hold one UIO2R motherboard or one
UIO6 or UIO6R motherboard complete with their
full complement of modules.
SIGA-UIO2R Universal Input/Output Module Board with Riser Inputs 2 Module Positions Data Sheet: 85001-0365
SIGA-UIO6R Universal Input/Output Module Board with Riser Inputs 6 Module Positions Data Sheet: 85001-0365
SIGA-UIO6 Universal Input/Output Module Board 6 Module Positions Data Sheet: 85001-0365
UIO6R
UIO2R
Signature Series
Input/Output Modules
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
29/50
SUBMIT
21
iO SeriesI n t e l l i g e n t I n i t i a t i n g D e v i c e s
Releasing Module
The Signature Series Releasing Module (SIGA-REL) is an analog addressable
module that works with fire suppression systems designed to release extinguish-
ing gas such as Halon. Its primary function is the control of sprinkler pre-action
routines and the initiation of suppression system deluge functions. The module
is easily configured in the field and offers a wide range of options that prevent
the unnecessary release of extinguishing agent.
The SIGA-REL is a network component consisting of:
Two supervised release circuits Two supervised pre-release circuits
One supervised manual
release input circuit
One supervised abort cir-
cuit for N/O abort switch
One first alarm output
relay (Form C Contact)
The releasing module includes a built-in timer that inhibits the deluge
function during the pre-action routine. One of four pre-action routines,
may be selected by means of dip-switches on the module. The
duration of automatic and manual time delays, as well as the abort
time settings are also selectable with dip-switches. The SIGA-REL
mounts inside an MFC-A cabinet or other suitable UL-listed electrical
enclosure. Each MFC-A will hold one SIGA-REL.
Available releasing module accessories include dedicated pull sta-
tions, abort switches and service switches. Together with the SIGA-
REL, they comprise a complete fire suppression package.
SIGA-REL Analog addressable releasing module Data Sheet: 85001-0531
RELA-ABT Abort station Data Sheet: 85001-0531
RELA-SRV Service disconnect station Data Sheet: 85001-0531
276A-REL Manual releasing station (single-action) Data Sheet: 85001-0531
278A-REL Manual releasing station (double-action) Data Sheet: 85001-0531
RELA-EOL Polarized end-of-line relay Data Sheet: 85001-0531
Abort
Manual Release
TB3 TB2
TB6
TB4 TB5
TB1
SW1-SW8
First alarm outputForm C 3 A @24 Vdc
Signature data in
Signature data out
+_
+_
Release CCT1
+
_24 Vdc in
24 Vdc out
Pre-release CCT2 (steady)
Pre-release CCT1 (pulsed 15/60)
SIGA-REL
+
_
1
23
4
RELA-EOL
1
23
4
RELA-EOL
Release CCT2
+_
+_
+_
+_
DS1
DS2
DS4 DS3DS5
DS6 DS7
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
30/50
Devices
SUBMIT
Intellige
ntControl
22
iO SeriesI n t e l l i g e n t I n i t i a t i n g D e v i c e s
Signature Series
Manual Pull Stations
NORMAL
8
4
7
3 2 1
DATA OUT (+)DATA IN (+)
DATA OUT (-)DATA IN (-)
To Next DeviceFrom Signature Controlleror Previous Device
Green LED(Normal)
Red LED(Alarm/Active)
REARVIEW
TB1
TB2
8
4
7
3 2 1
DATA OUT (+)DATA IN (+)
DATA OUT (-)DATA IN (-)
To NextDeviceFrom Signature Controlleror PreviousDevice
Green LED(Normal)
Red LED(Alarm/Active)
REARVIEW
TB1
TB2
Single Action Pull Stations
SIGA-270 series manual pull stations are made from
die-cast zinc and finished with red epoxy powder-
coat paint. With positive pull-lever operation, one
pull on the station handle breaks the rod and turns
in a positive alarm. Where two-stage operation is re-
quired, SIGA-270P pre-signal models are equipped
with a general alarm (GA) keyswitch.
SIGA-270 One Stage Fire Alarm Station, English Markings Data Sheet: 85001-0279
SIGA-270P Two Stage (Pre-signal) Fire Alarm Station, English Markings Data Sheet: 85001-0279
276-K2 GA Key for pre-signal station Data Sheet: 85001-0279
270-GLR 20 Break-rods for SIGA-270 series Data Sheet: 85001-0279
276B-RSB Surface Mount Box, Red for SIGA-270 series Data Sheet: 85001-0279
Double Action Pull Stations
The double action, single stage SIGA-278 station is a
contemporary style manual station made from durable
red LEXAN. To initiate an alarm, first lift the upper door,
then pull the alarm handle.
SIGA-278 Double Action (One Stage) Fire Alarm Station, English Markings Data Sheet: 85001-0279
276B-RSB Surface Mount Box, Red for SIGA-278 series Data Sheet: 85001-0279
276-GLR 20 Break-rods for SIGA-278 series Data Sheet: 85001-0279
Manual Station Relocator
The Manual Station Relocator is designed to lower the height of a fire alarm pull station to meet ADA
requirements. Most existing pull stations are mounted 60 inches (1524mm) or higher above the floor.
The Relocator lowers the height to 48 inches (1220mm) without the need for pulling new wires or
moving the existing electrical box.
RR-32RL Pull Station Relocator Data Sheet: 85001-0351
Stopper II
This unique device helps prevent false alarms without restricting legitimate ones. It consists of a tamper-
proof clear LEXAN polycarbonate shield and frame that fits easily over manual pull stations. When lifted,
it sounds a piercing warning horn.
STI-1100 (Flush) STI-1130 (Surface) Stopper II with Horn Data Sheet: 85001-0491
STI-1200 (Flush) STI-1230 (Surface) Stopper II without Horn Data Sheet: 85001-0491
STI-3100 (2" Spacer) STI-3004 (Conduit Insert) Spacers Data Sheet: 85001-0491
STI-3002 (Gasket) STI-3003 (Conduit Gasket) Weatherproofing Data Sheet: 85001-0491
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
31/5023
iO SeriesN o t i fi c a t i o n A p p l i a n c e s Wall Strobes, Horns & Chimes p. 25
Wall Speakers and Speaker-strobes p. 26
Ceiling Speakers, Horns, and Strobes p. 27
Outdoor Speakers and Speaker-Strobes p. 28
Outdoor Horns and Horn-Strobes p. 29
Audio Notification System p. 30
Firefighters Telephones p. 31
Harsh Environment Signals p. 32
Audible Signals p. 33
Accessories p. 34Notification
Appliances
iO Series notification appliances are high-performance devices finely tuned to deliver maximum
output in exchange for the lowest possible current draw. Covering the entire spectrum of life safetyapplications, these devices are durable, dependable, and virtually maintenance-free. And they
support a wide range of mounting options that make them ideal for new construction and retrofit
applications alike.
iO500 control panels come equipped with four notification
appliance circuits that can be wired to provide four Class
B NACs or two Class A NACs. The iO64 comes with two
Class B NACs. These may be configured for Class A op-
eration with the optional SA-CLA Class A Module installed.
iO Series NACs may be individually configured for continu-
ous, temporal, synchronized, and coded output.
iO Series NACs are configurable to fully support the advanced
signaling technology of Edwards Genesis and Enhanced
Integrity notification appliances. These devices offer precision
synchronization of strobes to UL 1971 standards. For Genesis
devices, enabling this feature allows connected horns to be
silenced while strobes on the same two-wire circuit continue
to flash until the panel is reset.
TB6
NAC3 -
NAC4+
NAC4 -
NAC3+
EOLR
+ +
+ +
Class A wiring
TB2
TB6
NAC1 -
NAC2+
NAC2-
NAC1+
+ +
+ +
+
+
- -
- -
- -
- -
-
-
Class B wiring
TB2
EOLR
NAC1 -
NAC2+
NAC2 -
NAC1+
+ +
+ +
- -
- -
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
32/5024
Intellige
ntControl
Devices
Appliances
SUBMIT
iO SeriesN o t i fi c a t i o n A p p l i a n c e s
Genesis Visual
& Audible SignalsThe award-winning Genesis line of products represents
excellence in fire alarm notification with looks, features, and
performance benefits designed with your project in mind.
Wall strobes, horns, and chimes about the size of a deck
of playing cards offer a discreet alternative to bulky devices,
while speakers and ceiling models with clean modern lines
blend inconspicuously with their surroundings.
Signaling on-demand
Though designed for discretion, Genesis signals are also
engineered to command attention. Wall-penetrating high
dB output and patented FullLight strobe technology im-
merse the protected area with levels of light and sound
that simply cant be ignored all in exchange for the low-
est current demands of any device in their class.
Genesis brings on-demand signaling to every applica-
tion with an unparalleled range of field-configurable
options: horns and chimes with high/low dB output
settings; speakers with multiple wattage tap selections;and strobes with selectable candela output and flash
rate options that put you in the drivers seat when time
is short, budgets slim, and manpower at a premium. It
also means fewer parts to stock, less inventory to worry
about, and the flexibility to meet changing demands on
the fly without having to reinstall equipment or order
more parts!
Application flexibility
Whether youre designing for a new landmark structure,
or simply retrofitting a local strip mall, competitively-priced Genesis signals bring value, good looks, and
installation flexibility to every application. Contact Ed-
wards today to learn how your signal solutions can be
the model of discretion.
A complete line engineered to
deliver innovative features and
superb output.
Wall Strobes, Horns, Chimes,
p. 25
Wall Speakers and Speaker-strobes,
p. 26
Ceiling Speakers, Horns,
Strobes, p. 27
Outdoor Speakers, Speaker-Strobes,
p. 28
Outdoor Horns, Horn-Strobes, p. 29
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
33/5025
SUBMIT
iO SeriesN o t i fi c a t i o n A p p l i a n c e s
Genesis Series
Wall Strobes,
Horns & ChimesGenesis signals feature textured housings in architecturally neutral white or
traditional fire red. An ingenious iconographic symbol indicates the purpose
of the device. This universal symbol is code-compliant and is easily recog-
nized by all building occupants regardless of what language they speak.
models with FIRE and ALERT markings are also available.
Genesis strobesoffer 15 to 110 candela output, which is selectable with a conveniently-located switch on the side of the
device. The candela output setting remains clearly visible even after final installation, yet it stays locked in place to prevent
unauthorized tampering. (Data Sheet 85001-0573)
White housing White housing Red housing Red housing Fire Alarm Appliances
no marking with FIRE no marking with FIRE (with Running Man icon)
G1-VM G1F-VM G1R-VM G1RF-VM Strobe only (15/30/75/110 cd)
G1F-V1575 G1RF-V1575 Strobe only (15/75 cd), 24 V
Genesis Horns and Horn-strobesreach output levels as high as 99 dB and features a unique multiple frequency tone that
results in excellent wall penetration and an unmistakable warning of danger. Horns may be configured for either coded or non-
coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB.
(Data Sheet 85001-0573)
White housing White housing Red housing Red housing Fire Alarm Appliances
no marking with FIRE no marking with FIRE (with Running Man icon)
G1-HD G1F-HD G1R-HD G1RF-HD Horn only (high/low dB)
G1-HDVM G1F-HDVM G1R-HDVM G1RF-HDVM Horn-strobe (15/30/75/110, high/low dB)
G1F-HDV1575 G1RF-HDV1575 Horn-strobe (15/75 cd, high/low dB), 24 V
G1-P G1F-P G1R-P G1RF-P Steady horn (not compatible with Signal Master)
Genesis chimes and chime-strobesproduce a pleasing mellow tone. When steady (non-stroked) voltage is applied, the
chime automatically pulses at 60 strokes per minute, or may be field-configured for temporal output. When installed with a
GIM Signal Master Module, the chime may also be field-configured for coded operation, which enables the chime output
to match the rate that voltage is applied to the circuit. Chimes may be set for low dB output with a jumper cut that reduces
sound output by about 5 dB. (Data Sheet 85001-0574)
White housing Red housing Chimes and Chime-strobes
G1-CVM G1R-CVM Chime-strobe (15/30/75/110, high/low dB)
G1-C G1R-C Chime only (high/low dB)
Trim platesfor wall horns, chimes, and strobes are ideal for covering openings left behind during retrofits.
White plate White plate Red plate Red plate White plateFire Trim Plates
no marking with FIRE no FIRE with FIRE with ALERT
G1T G1T-FIRE G1RT G1RT-FIRE G1WT-ALERT Trim plate for 2-gang or 4 boxes
15/75 cd models provide fixed output. The 15 cd output component complies with UL1971. The 75 cd output component complies with UL 1638.
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
34/5026
Intellige
ntControl
Devices
Appliances
SUBMIT
iO SeriesN o t i fi c a t i o n A p p l i a n c e s
Genesis speakersinclude a DC blocking capacitor to
allow electrical supervision of the audio distribution circuit.
Models for 25 VRMS
and 70 VRMS
circuits are available. The
mylar speaker with its sealed back construction provides
extra durability and improved audibility. W to 2 W opera-
tion is selectable with a conveniently-located switch on the
bottom of the device. (Data Sheet 85001-0549)
Speaker-strobesfeature 15, 30, 75 or 110 candela output,
selectable with a conveniently-located switch on the bottom
of the device.
Genesis speakers are
available with white or
red housings and with or
without FIRE markings.
1
Bottom View
Wattage switch
15
Candela switch
il i
i i i
Candela and wattage settings remain clearly
visible even after final installation.
Genesis Series
Wall Speakers and
Speaker-strobes
SPKR
S+
C S-
Polarity shown inalarm condition
To next deviceor end of line
device
++
SPKR
S+
C S-
S S
+ +
To listed fire alarm control panel(supervised signal circuit
20-24 Vdc)
To listed fire alarm control panel(supervised amplifier signal circuit
25.2 or 70.7V rms)
White housing White housing Red housing Red housing Fire Alarm Speakers no marking with FIRE no marking with FIRE (with Running Man icon)
G4-S2 G4F-S2 G4R-S2 G4RF-S2 25 V Speaker
G4-S7 G4F-S7 G4R-S7 G4RF-S7 70 V Speaker
G4-S2VM G4F-S2VM G4R-S2VM G4RF-S2VM 25 V Speaker-strobe (15/30/75/110 cd settings)
G4-S7VM G4F-S7VM G4R-S7VM G4RF-S7VM 70 V Speaker-strobe (15/30/75/110 cd settings)
G4F-S7V1575 G4RF-S7V1575 70 V Speaker (15/75 cd)
#18 - #12 AWG terminals
ideal for long runs,
existing wiring
All speakers feature selectable , , 1, or 2 watt operation. Multi-candela strobes feature selectable 15, 30, 75, or 110 cd output.
-
8/11/2019 85005-0132 -- IO Series Submittal Guide
35/5027
SUBMIT
iO SeriesN o t i fi c a t i o n A p p l i a n c e s
Select
, , 1, or 2
watt operation!
The Genesis line of multi-candela and multi-wattage ceiling
signals feature all the hallmarks that have made Genesis
products a big hit with designers, engineers, building
owners, and installers everywhere. ESTs precision timing
electronics, and low current draw bring the benefits of the
popular Genesis wall-mount models to ceiling applications.
These signals are 30 per cent slimmer than comparable
signals on the market. They are compatible with standard
4-inch (10 cm) square electrical boxes and dont require
extension rings or trim plates. No mounting screws are
visible when the unit is installed, providing a clean, finished,unobtrusive appearance that blends with any decor. These
signals are also listed for wall mount applications.
Select
15/30/75/95
and 95/115/150/177
candela output!
Genesis Series
Ceiling Speakers,
Horns, and Strobes
Fire Alarm Appliances
White housing White housing Red housing All fire alarm appliances come
no marking with FIRE with FIRE with the Running Man Icon
GC-VM GCF-VM GCFR-VM Strobe, 15/30/75/110 (standard output) cd, selectable
GC-VMH GCF-VMH Strobe, 95/115/150/177 (high output) cd, selectable
GC-HDVM GCF-HDVM GCFR-HDVM Horn-strobe, 15/30/75/110 (standard output) cd, selectable
GC-HDVMH GCF-HDVMH Horn-strobe, 95/115/150/177 (high output) cd, selectable
GC-S2VM GCF-S2VM Speaker-strobe, 25 V, 15/30/75/110 cd selectable
GC-S2VMH GCF-S2VMH Speaker-strobe, 25 V, 95/115/150/177 cd selectableGC-S7VM GCF-S7VM GCFR-S7VM Speaker-strobe, 70 V, 15/30/75/110 cd selectable
GC-S7VMH GCF-S7VMH Speaker-strobe, 70 V, 95/115/150/177 cd selectable
GC-S2 GCF-S2 GCFR-S2 Speaker, 25 V
GC-S7 GCF-S7 GCFR-S7 Speaker, 70 V
All speakers feature selectable , , 1, or 2 watt operation. All horns feature high or low dB output.
Multi-