84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

82
PLANNING GUIDE www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. X.1 Table of Contents TABLE OF CONTENTS 1/2 Revised 09/07/11 WALL OVENS 1.1-1.16 Distinctive Single (DO) 1.1-1.2 Distinctive Double (DO) 1.3-1.4 Discovery Single (EO/MOH/MOV) 1.5-1.6 Discovery Double (EO/MOH/MOV) 1.7-1.8 Renaissance Single (EOR/MOR) 1.9-1.10 Renaissance Double (EOR/MOR) 1.11-1.12 Renaissance Single (RO/ROV) 1.13-1.14 Renaissance Double (RO/ROV) 1.15-1.16 WARMING DRAWERS 2.1-2.3 Epicure ® , Millennia ® , Integrated 2.1-2.3 ELECTRIC COOKTOPS 3.1-3.3 Millennia (ETT/MET) 3.1-3.3 GAS COOKTOPS 4.1-4.21 Epicure Slide-In (EG) 4.1-4.4 Drop-In (SGM) 4.5-4.9 Renaissance Drop-In (RGC) 4.10-4.13 Distinctive Slide-In (DRT) 4.14-4.17 Distinctive Drop-In (DCT) 4.18-4.21 RANGES 5.1-5.15 30” Epicure All Gas (ER30G) 5.1-5.3 36” Epicure All Gas (ER36G) 5.4-5.6 30” Epicure Dual Fuel (ER30D) 5.7-5.9 36”, 48” Epicure Dual Fuel (ER36D/ER48D) 5.10-5.11 30” Millennia Electric (MRES30) 5.12-5.13 30” Distinctive Dual Fuel (DR30D) 5.14-5.15 DUCT PLANNING GUIDE 6.1 HOODS 7.1-7.8 Millennia Chimney Style, Wall Mount (DHW) 7.1 Millennia Island Style (DHI) 7.2 Glass Wall Mount (PHW) 7.3 Epicure/Millennia Wall Mount (EH, EHR, MH) 7.4-7.6 Integrated Ventilation System (IVS, IVSR) 7.7 Custom Hood Liner (IHL) 7.8 RAISED VENTS 8.1-8.13 Epicure Slim Chassis (ERV, PRV) 8.1-8.3 Epicure for ER 36", 48" Ranges (ERV-ER) 8.4-8.6 Standard Chassis (RV) 8.7-8.13 BLOWERS 9.1-9.6 Cabinet Style for RV Series Raised Vents (CABP) 9.1 In-Line (ILHSF) 9.2-9.3 Remote (REMP) 9.4-9.6 DISHWASHERS 10.1-10.6 24” Front Control Panel DDWF24S 10.1 -10.3 24” Hidden Control Panel EDWH/IDWH 10.4 -10.6 REFRIGERATION 11.1-11.14 Epicure Built-In Wine-Beverage cooler (EF24) 11.1 Epicure Outdoor Refrigerator (OF24) 11.2 36” Freestanding Glass 3-Door 11.3 36” Freestanding (EF/IF 3-Door) 11.4-11.7 42”, 48” Built-In (EF/IF) 11.8-11.13 36” Freestanding with Dispenser (EF36IWF) 11.14 MICROWAVES 12.1-12.7 Standard Type, Stainless Steel (DMW2420S) 12.1 Trim Kits for Above (AMTK/AOMTK) 12.1 Standard Type, Black Glass (DMT2420BK) 12.2 Trim Kits for Above (AMTK/AOMTK) 12.2 Convection Type (DCM24) 12.3 Trim Kits for Above (ACTK/AOCTK) 12.3 Standard Type, Over Range Mount (PMOR3021) 12.4 Convection Type, Over Range Mount (PCOR30) 12.5 24" Microwave-In-A-Drawer (MMD24) 12.6 30" Microwave-In-A-Drawer (MMD30/MMDV30) 12.7 OUTDOOR GRILLS 13.1-13.5 Epicure (OB/OBS) 13.1-13.3 Built-In Trim kit for OB/OBS Series Grill (OBGT) 13.4 Outdoor Grill Carts, OB/OBS Series Grill (OBC) 13.5 BACKGUARDS 14.1 Backguard, Stand-Alone (AEB) 14.1

Transcript of 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

Page 1: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. X.1

Table of Contents

TABLE OF CONTENTS

1/2Revised09/07/11

wALL OvENS 1.1-1.16Distinctive Single (DO) 1.1-1.2Distinctive Double (DO) 1.3-1.4Discovery Single (EO/MOH/MOV) 1.5-1.6Discovery Double (EO/MOH/MOV) 1.7-1.8Renaissance Single (EOR/MOR) 1.9-1.10Renaissance Double (EOR/MOR) 1.11-1.12Renaissance Single (RO/ROV) 1.13-1.14Renaissance Double (RO/ROV) 1.15-1.16

wArmING DrAwErS 2.1-2.3Epicure®, Millennia® , Integrated 2.1-2.3

ELECTrIC COOkTOPS 3.1-3.3Millennia (ETT/MET) 3.1-3.3

GAS COOkTOPS 4.1-4.21Epicure Slide-In (EG) 4.1-4.4Drop-In (SGM) 4.5-4.9Renaissance Drop-In (RGC) 4.10-4.13Distinctive Slide-In (DRT) 4.14-4.17Distinctive Drop-In (DCT) 4.18-4.21

rANGES 5.1-5.1530” Epicure All Gas (ER30G) 5.1-5.336” Epicure All Gas (ER36G) 5.4-5.630” Epicure Dual Fuel (ER30D) 5.7-5.936”, 48” Epicure Dual Fuel (ER36D/ER48D) 5.10-5.1130” Millennia Electric (MRES30) 5.12-5.1330” Distinctive Dual Fuel (DR30D) 5.14-5.15

DUCT PLANNING GUIDE 6.1

HOODS 7.1-7.8Millennia Chimney Style, Wall Mount (DHW) 7.1Millennia Island Style (DHI) 7.2Glass Wall Mount (PHW) 7.3Epicure/Millennia Wall Mount (EH, EHR, MH) 7.4-7.6Integrated Ventilation System (IVS, IVSR) 7.7Custom Hood Liner (IHL) 7.8

rAISED vENTS 8.1-8.13Epicure Slim Chassis (ERV, PRV) 8.1-8.3Epicure for ER 36", 48" Ranges (ERV-ER) 8.4-8.6Standard Chassis (RV) 8.7-8.13

BLOwErS 9.1-9.6Cabinet Style for RV Series Raised Vents (CABP) 9.1In-Line (ILHSF) 9.2-9.3Remote (REMP) 9.4-9.6

DISHwASHErS 10.1-10.624” Front Control Panel DDWF24S 10.1 -10.324” Hidden Control Panel EDWH/IDWH 10.4 -10.6

rEFrIGErATION 11.1-11.14Epicure Built-In Wine-Beverage cooler (EF24) 11.1 Epicure Outdoor Refrigerator (OF24) 11.236” Freestanding Glass 3-Door 11.336” Freestanding (EF/IF 3-Door) 11.4-11.742”, 48” Built-In (EF/IF) 11.8-11.1336” Freestanding with Dispenser (EF36IWF) 11.14

mICrOwAvES 12.1-12.7Standard Type, Stainless Steel (DMW2420S) 12.1Trim Kits for Above (AMTK/AOMTK) 12.1Standard Type, Black Glass (DMT2420BK) 12.2Trim Kits for Above (AMTK/AOMTK) 12.2Convection Type (DCM24) 12.3Trim Kits for Above (ACTK/AOCTK) 12.3Standard Type, Over Range Mount (PMOR3021) 12.4Convection Type, Over Range Mount (PCOR30) 12.524" Microwave-In-A-Drawer (MMD24) 12.630" Microwave-In-A-Drawer (MMD30/MMDV30) 12.7

OUTDOOr GrILLS 13.1-13.5Epicure (OB/OBS) 13.1-13.3Built-In Trim kit for OB/OBS Series Grill (OBGT) 13.4Outdoor Grill Carts, OB/OBS Series Grill (OBC) 13.5

BACkGUArDS 14.1Backguard, Stand-Alone (AEB) 14.1

Page 2: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. X.2

COmBINATIONINSTALLATIONS CI.1-CI.27

Drop-In Gas Cooktop/Raised Vent/SingleWall Oven CI.1Drop-In Electric Cooktop/Raised Vent/SingleWall Oven CI.2Drop-In Gas Cooktop/Slim Raised Vent/SingleWall Oven CI.3Drop-In Electric Cooktop/Slim Raised Vent/SingleWall Oven CI.4Single Wall Oven/Drop-In Cooktop CI.5Raised Vent/30” Epicure Range CI.6Raised Vent/36-48” Epicure Range CI.7Slim Raised Vent/Millennia Range CI.8Slim Raised Vent/Epicure Slide-In Cooktop CI.9Slim Raised Vent/Distinctive Slide-In Cooktop CI.10Drop-In Gas Cooktop/Raised Vent CI.11-CI.12DCT Drop-In Gas Cooktop/Raised Vent CI.13Drop-In Electric Cooktop/Raised Vent CI.14Drop-In Gas Cooktop/Slim Raised Vent CI.15-CI.16Drop-In Electric Cooktop/Slim Raised Vent CI.17 Warming Drawer/Drop-In Cooktop CI.18Warming Drawer/Slide-In Cooktop CI.19Warming Drawer (stacked)/Slide-In Cooktop CI.20Warming Drawer (side-by-side)/Slide-In Cooktop CI.21Microwave/Warming Drawer/Distinctive or Renaissance Wall Oven CI.22Microwave/Warming Drawer CI.23Microwave/Distinctive or Renaissance Wall Oven/Warming Drawer CI.24Microwave/Discovery Wall Oven/Warming Drawer CI.25Microwave/Warming Drawer/Discovery Wall Oven CI.26Discovery Wall Oven/Microwave In-A-Drawer/ Warming Drawer CI.27

Table of Contents

TABLE OF CONTENTS

2/2Revised09/07/11

Page 3: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.1

DO

Single, Distinctive wall Oven

(A) Overall Width

(B) Chassis Width

(C) Overall Height

(D)* Chassis Height

(E) Control Panel

Overlay29 3/4”

(75.6 cm)28 3/8”

(72.1 cm)28 7/16” (72.4 cm)

27 1/2” (69.9 cm)

15/16” (2.4 cm)

* To top of chassis notch behind control panel

(F) Utility Cutout Width

(G) Utility Cutout Height

(H) Utility Cutout Depth

(J) Control Panel Depth

(K) Notch Depth

(L) Chassis Depth

(M) Notch Height

5” (12.7 cm)

5 ¼” (13.3 cm)

6” (15.2 cm)

1” (2.5 cm)

1 5/8” (4.1 cm)

24” (61.0 cm)

1” (2.5 cm)

21 1/8”(53.7 cm)

ELECTRICAL SPECIFICATIONSDedicated Circuit

Requirements Total Connected Load

240 Vac 60 Hz., 4-wire,*** 30 Amp. 5.3 kW (23 Amp.)

*** Two 120 Vac hot (L1 and L2), one neutral, one groundThe above specifications are for reference only. See the appliance data plate for exact specifications.

C

J

B

H

G

F

A

Chassis NotchSide View

Control panel front Top of

chassis

Top of chassis

Utilitycutout

¾” Conduit:60” (152 cm)

longK

L

ME

D

Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated

Document # PG01-007 Revised 05/25/10 Page 1/2

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

mODEL DO130

Page 4: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.2

Single, Distinctive wall Oven

DO

1 1/2”(3.8 cm)

typical counter

1“ (2.5 cm) Min.to combustible floor

3/4” (1.9 cm)support platform

1“ (2.5 cm) Min. to combustibles

Recommendedelectricallocation

4” typical toe kick

36”(91.4 cm) P

R

SINGLE wALL OvEN - INSTALLED UNDEr COUNTEr

Recommendedelectricallocation

Alternateelectricallocation

4” typical toe kick

N

P

R3/4” (1.9 cm)

support platform

31 1/4” (79.4 cm)recommended

1” (2.5 cm) Min.to bottom of cabinet door

1” (2.5 cm) Min.to top of

cabinet door

SINGLE wALL OvEN - CUTOUT DImENSIONS

(N) Minimum Cabinet Width

(P) Minimum Cut Out Width

(R) Minimum Cutout Height

30” (76.2 cm)

28 ½” (72.4 cm)

27 5/8” (70.2 cm)

Minimum Interior Cabinet Depth: 24” (61.0 cm)

Cabinet/countertop tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated

Document # PG01-007 Revised 05/25/10 Page 2/2

Page 5: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.3

DO

Double, Distinctive wall Oven

(A) Overall Width

(B) Chassis Width

(C) Overall Height

(D)* Chassis Height

(E) Control Panel

Overlay29 3/4”

(75.6 cm)28 3/8”

(72.1 cm)49 15/16”(126.8 cm)

49 1/16”(124.6 cm)

15/16” (2.4 cm)

* To top of chassis notch behind control panel

(F) Utility Cutout Width

(G) Utility Cutout Height

(H) Utility Cutout Depth

(J) Control Panel Depth

(K) Notch Depth

(L) Chassis Depth

(M) Notch Height

5” (12.7 cm)

5 ¼” (13.3 cm)

6” (15.2 cm)

1” (2.5 cm)

1 5/8” (4.1 cm)

24” (61.0 cm)

1” (2.5 cm)

21 1/8”(53.7 cm)

ELECTRICAL SPECIFICATIONSDedicated Circuit

Requirements Total Connected Load

240 Vac 60 Hz., 4-wire,** 40 Amp. 7.8 kW (33 Amp.)

** Two 120 Vac hot (L1 and L2), one neutral, one ground.The above specifications are for reference only. See the appliance data plate for exact specifications.

C

J

B

H

G

F

A

K

L

ME

Chassis NotchSide View

Control panel front Top of

chassis

Top ofchassis

Utilitycutout

Conduit:60” (152 cm)

Long

D

Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated

mODEL DO230

Document # PG01-008 Revised 05/25/10 Page 1/2

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

Page 6: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.4

Double, Distinctive wall Oven

DO

4” typical toe kick

Recommendedelectricallocation

N

P

R

3/4” (1.9 cm)support platform

1” (2.5 cm) min.to bottom of cabinet door

1” (2.5 cm) Min.to top of

drawer face

9 5/8” (24.4 cm)recommended

DOUBLE wALL OvEN - CUTOUT DImENSIONS

(N) Minimum Cabinet Width

(P) Minimum Cut Out Width

(R) Minimum Cutout Height

30” (76.2 cm)

28 ½” (72.4 cm)

49 1/8” (124.8 cm)

Minimum Interior Cabinet Depth: 24” (61.0 cm)

Cabinet/countertop tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated

Document # PG01-008 Revised 05/25/10 Page 2/2

Page 7: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.5

27 and 30 Inch wide, Single,Discovery wall Ovens

EO, mOH, mOv

G

DE

F

C

66” (167.6 cm)Flexible conduit

A

B

1 1/4”(3.2 cm)

H

Chassis notchside view

Control panelfront

Top ofchassis

L

K

Top ofchassis

Utilitycutout

J

Dedicated CircuitRequired

TotalConnected Load

ApproximateShipping Weight

240 Vac, 4-wire*,60Hz, 30 Amp. 4.6 kW (19.5 Amp.) 240 lbs.

* Two 120 Vac hot (L1 and L2), one neutral, one ground.

PrODUCT DImENSIONS

HANDLE DImENSIONS - SIDE vIEw

EO - Epicure ® ® MOH/MOV - Millennia

1 1/4”(3.2 cm)

1 1/4”(3.2 cm)

3 11/16”(9.4 cm)

3 5/16”(8.4 cm)

Model A B C D E F G H J K LEO127

27”(68.6 cm)

27 15/16” (71.0 cm)

23 3/8”(59.4 cm)

2 5/16”(5.9 cm)

7 3/8”(18.7 cm)

6 3/8”(16.2 cm)

27 3/8”(69.5 cm)

25 3/8”(64.4 cm)

9/16”(1.4 cm)

1”(2.5 cm)

1 7/8”(4.6 cm)

MOH127

MOV127

EO13030”

(76.2 cm)28 3/8”

(72.0 cm)MOH130

MOV130

22 11/16”(57.6 cm)

Product tolerances: ±1/16” (±1.6 mm), unless otherwise stated.

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

Document # PG01-001 Revised 01/25/11 Page 1/2

Page 8: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.6

27 and 30 Inch wide, Single,Discovery wall Ovens

EO, mOH, mOv

NOTES:1. 24” (61.0 cm) minimum interior cabinet depth. Back of

cabinet may need to be removed.2. 3/4” (1.9 cm) support platform (flush with cutout).

CUTOUT DImENSIONS

C

AB

4“ typical toe kick (shown)

Alternateelectrical location3/4” (1.9 cm)

support platform

Recommendedelectrical location

31 1/4” (79.4 cm)recommended

(may be altered)

1 ¾“ (4.5 cm) min.clear to top ofdoor for heat

exhaust

1“ (2.5 cm) min. clear to

bottomof door

CUTOUT DImENSIONS -UNDEr-COUNTEr INSTALLATION

36” Typical(91.4 cm)

1 1/2”(3.8 cm)

typical counter

4“ typical toe kick (shown)

1“ (2.5 cm) min. to combustibles

AB

3/4” (1.9 cm)support platform

Recommendedelectrical location

1 ¾“ (4.5 cm) min.to combustible floor

Model A B CEO127

27 7/16”(69.7 cm)

25 1/2”(64.8 cm)

27”(68.6 cm)MOH127

MOV127

EO13028 1/2”

(72.4 cm)30”

(76.2 cm)MOH130

MOV130

3. 1/8” (3 mm) minimum clearance from appliance to adjacent cabinet doors/drawers.

4. Two (2) Single Ovens are not approved in a stack configuration.

Alternateelectrical locations

4“ (10.2 cm) min.between cutout

Recommended electrical location

4“ typical toe kick (shown)

1“ (2.5 cm) min. to combustibles

AB

3/4” (1.9 cm)support platform

AB

3/4” (1.9 cm)support platform

36” Typical(91.4 cm)

1 1/2”(3.8 cm)

typical counter

1 ¾“ (4.5 cm) min.to combustible floor

CUTOUT DImENSIONS SIDE-BY-SIDE UNDEr-COUNTEr INSTALLATION

Cutout tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated.

Document # PG01-001 Revised 01/25/11 Page 2/2

Page 9: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.7

27 and 30 Inch wide, Double,Discovery wall Ovens

EO, mOH, mOv

Dedicated CircuitRequired

TotalConnected Load

ApproximateShipping Weight

240 Vac,4-wire*, 60 Hz, 50 Amp. 9.25 kW (38.9 Amp.) 415 lbs.

* Two 120 Vac hot (L1 and L2), one neutral, one ground.

PrODUCT DImENSIONS

G

DE

F

C

66” (167.6 cm)Flexible conduitA

B

1 1/4”(3.2 cm)

H

Chassis notchside view

Control panel front

Top ofchassis

Top ofchassis

Utilitycutout

L

KJ

22 11/16”(57.6 cm)

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

Product tolerances: ±1/16” (±1.6 mm), unless otherwise stated.

Model A B C D E F G H J K LEO227

27”(68.6 cm)

51 1/16” (129.7 cm)

23 3/8”(59.4 cm)

2 5/16”(5.9 cm)

7 3/8”(18.7 cm)

6 3/8”(16.2 cm)

50 1/2”(128.3 cm)

25 3/8”(64.4 cm)

9/16”(1.4 cm)

1”(2.5 cm)

1 7/8”(4.6 cm)

MOH227

MOV227

EO23030”

(76.2 cm)28 3/8”

(72.0 cm)MOH230

MOV230

Document # PG01-002 Revised 01/25/11 Page 1/2

Page 10: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.8

27 and 30 Inch wide, Double,Discovery wall Ovens

EO, mOH, mOv

NOTES:1. 24” (61.0 cm) minimum interior cabinet depth. Back of

cabinet may need to be removed.2. 3/4” (1.9 cm) support platform (flush with cutout).3. 1/8” (3 mm) minimum clearance from appliance to

adjacent cabinet doors/drawers.

CUTOUT DImENSIONS

A

B

4“ typical toe kick (shown)

3/4” (1.9 cm)support platform

Recommendedelectrical location

9 5/8” (24.4 cm)recommended

(may be altered)

1 ¾“ (4.5 cm) min.clear to top ofdoor for heat

exhaust

1“ (2.5 cm) min.clear to

bottom ofdoor

C

Model A B CEO227

50 9/16”(128.4 cm)

25 1/2”(64.8 cm)

27”(68.6 cm)MOH227

MOV227

EO23028 1/2”

(72.4 cm)30”

(76.2 cm)MOH230

MOV230

Document # PG01-002 Revised 01/25/11 Page 2/2

HANDLE DImENSIONS - SIDE vIEw

EO - Epicure ® ® MOH/MOV - Millennia

1 1/4”(3.2 cm)

1 1/4”(3.2 cm)

3 11/16”(9.4 cm)

3 5/16”(8.4 cm)

Cutout tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated.

Page 11: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.9

27”, 30”, 36” wide, Single,renaissance wall Ovens

EOr, mOr

Model Number

(A) Overall Width

(B)* Chassis Width

(C) Overall Height

(D)** Chassis Height

(E) Control Panel

OverlayEORS127/MORS127

26 7/8” (68.3 cm)

25 3/8” (64.5 cm) 28 7/16”

(72.4 cm)27 1/2”

(69.9 cm)15/16”

(23.8 cm)EORS130/MORS130

29 7/8” (75.9 cm)

28 3/8” (72.1 cm)

EORS136 35 7/8” (91.1 cm)

34 3/8” (87.3 cm)

28 1/8” (71.4 cm)

27 1/4” (69.2 cm)

7/8” (2.2 cm)

* Width at light covers on sides ** To top of chassis notch behind control panel

(F) Utility Cutout Width

(G) Utility Cutout Height

(H) Utility Cutout Depth

(J) Control Panel Depth

(K) Notch Depth

(L) Chassis Depth

(M) Notch Height

All models 5” (12.7 cm)

5 ¼” (13.3 cm)

6” (15.2 cm)

1” (2.54 cm)

1 1/8” (2.9 cm)

24” (61.0 cm)

1” (2.5 cm)

21 1/8”

3 3/8”(8.6 cm)

1”(2.5 cm)

1”(2.5 cm)

Epicure Millennia - (Handle is integral)

HANDLE DImENSIONS

Model Number

Dedicated Circuit Requirements

Total Connected Load

EORS127

240 Vac 60 Hz., 4-wire***, 30 Amp.

5.0 kW (20.8 Amp.)MORS127EORS130MORS130EORS136 5.3 kW (22 Amp.)

*** Two 120 Vac hot (L1 and L2), one neutral, one groundThe above specifications are for reference only. See the appliance data plate for exact specifications.

C

J

B*

H

G

F

A

Chassis NotchSide View

Control panel front Top of

chassis

Top of chassis

Utilitycutout

Lightcover

Conduit:60” (152 cm)

LongK

L

ME

D

All tolerances: ±1/16” (±1.6 mm) unless otherwise stated

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

Document # PG01-003 Revised 05/25/10 Page 1/2

Page 12: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.10

27”, 30”, 36” wide, Single,renaissance wall Ovens

EOr, mOr

1 1/2”(3.8 cm)

typical counter

1“ (2.5 cm) Min.to combustible floor

3/4” (1.9 cm)support platform

1“ (25 mm) Min. to combustibles

Recommendedelectricallocation

4” typical toe kick

36”(91.4 cm) P

R

SINGLE wALL OvEN - INSTALLED UNDEr COUNTEr

Recommendedelectricallocation

Alternateelectricallocation

4” typical toe kick

N

P

R3/4” (1.9 cm)

support platform

31 1/4” (79.4 cm)recommended

1” (2.5 cm) Min.to bottom of cabinet door

1” (2.5 cm) Min.to top of

cabinet door

SINGLE wALL OvEN - CUT OUT DImENSIONS

Model Number (N) Minimum Cabinet Width

(P) Minimum Cut Out Width

(R) Minimum Cut out Height

EORS127/MORS127

27” (68.6 cm)

25 ½” (64.8 cm) 27 5/8”

(70.2 cm)EORS130/MORS130

30” (76.2 cm)

28 ½” (72.4 cm))

EORS136 36” (91.4 cm)

34 ½” (87.6 cm)

27 ½” (69.9 cm)

Minimum Interior Cabinet Depth: 24” (61.0 cm)

All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated

Document # PG01-003 Revised 05/25/10 Page 2/2

Page 13: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.11

27”, 30”, 36” wide, Double,renaissance wall Ovens

EOr, mOr

C

J

B*

H

G

F

A

K

L

ME

Chassis NotchSide View

Control panel front Top of

chassis

Top ofchassis

Utilitycutout

Lightcover

Lightcover

Conduit:60” (152 cm)

Long

D

3 3/8”(8.6 cm)

1”(2.5 cm)

1”(2.5 cm)

Model Number

(A) Overall Width

(B)* Chassis Width

(C) Overall Height

(D)** Chassis Height

(E) Control Panel

Overlay

EORX227/MORX227

26 7/8” (68.3 cm)

25 3/8” (64.5 cm) 49 15/16”

(127.0 cm)49 1/16”

(124.6 cm)7/8”

(2.2 cm)EORX230/MORX230

29 7/8” (75.9 cm)

28 3/8” (72.1 cm)

X = Number of convection ovens: S = single, D = double * Width at light covers on sides ** To top of chassis notch behind control panel

(F) Utility Cutout Width

(G) Utility Cutout Height

(H) Utility Cutout Depth

(J) Control Panel Depth

(K) Notch Depth

(L) Chassis Depth

(M) Notch Height

All models

5” (12.7 cm)

5 ¼” (13.3 cm)

6” (15.2 cm)

1” (2.5 cm)

1 1/8” (2.9 cm)

24” (61.0 cm)

1” (2.5 cm)

Model Number Dedicated Circuit Requirements

Total Connected Load

EORS227/ MORS227 240 Vac 60 Hz, 4-wire***, 40 Amp. 7.8 kW (33 Amp.)

EORS230/ MORS230EORD227/ MORD227 240 Vac 60 Hz,

4-wire***, 50 Amp. 10.0 kW (42 Amp.)EORD230/ MORD230

*** Two 120 Vac hot (L1 and L2), one neutral, one groundThe above specifications are for reference only. See the appliance data plate for exact specifications.

21 1/8”

Epicure Millennia (Handle is integral)

HANDLE DImENSIONS

All tolerances: ±1/16” (±1.6 mm) unless otherwise stated

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

Document # PG01-004 Revised 05/25/10 Page 1/2

Page 14: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.12

27”, 30”, 36” wide, Double,renaissance wall Ovens

EOr, mOr

4” typical toe kick

Recommendedelectricallocation

N

P

R

3/4” (1.9 cm)support platform

1” (2.5 cm) min.to bottom of cabinet door

1” (2.5 cm) Min.to top of

drawer face

9 5/8” (24.4 cm)recommended

DOUBLE wALL OvEN - CUT OUT DImENSIONS

Model Number

(N) Minimum Cabinet Width

(P) Minimum Cut Out Width

(R) Minimum Cut-out Height

EORX227/MORX227 27” (68.6 cm) 25 ½” (64.8 cm)

49 1/8” (124.8 cm)EORX230/MORX230 30” (76.2 cm) 28 ½” (72.4 cm)

X = Number of convection ovens: S = Single, D = Double

All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated

Document # PG01-004 Revised 05/25/10 Page 2/2

Page 15: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.13

rO130, rOv130

30 Inch, Single, renaissance wall Oven

(A) Overall Width

(B) Chassis Width

(C) Overall Height

(D) Chassis Height

(E) Control Panel

Overlay29 7/8”

(75.9 cm)28 3/8”

(72.1 cm)28 5/8”

(70.2 cm)26 5/8”

(67.6 cm)1”

(2.5 cm)

(F) Utility Cutout Width

(G) Utility Cutout Height

(H) Utility Cutout Depth

(J) Control Panel Depth

(K) Chassis Depth

6 1/4”(15.9 cm)

4 3/4”(12.1 cm)

7 3/4”(19.7 cm)

1 3/16”(3.0 cm)

23 5/8”(60.0 cm)

ELECTRICAL SPECIFICATIONSDedicated Circuit

Requirements Total Connected Load

240 Vac 60 Hz., 4-wire,* 30 Amp. 6.0 kW (25.0 Amp.)

* Two 120 Vac hot (L1 and L2), one neutral, one ground. Fuse/circuit breaker on both L1 and L2.The above specifications are for reference only. See the product data plate for exact specifications.

Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated

Document # PG01-009 Revised 09/07/11 Page 1/2

WARNING• Observe all governing codes and ordinances during

planning and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

C

J

B

H

G

F

A

Control panelside view

Control panel front Top of

chassis

Top of chassis

Utilitycutout

Conduit:60” (152 cm)

long

K

E

D

21 1/8”

3 1/2”(8.9 cm)

3 3/16”(8.1 cm)

1 1/8”(2.9 cm)

1 1/8”(2.9 cm)

HANDLE DImENSIONS

Epicure Millennia (Order kit #AMOH30))

Page 16: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.14

30 Inch, Single, renaissance wall Oven

rO130, rOv130

SINGLE wALL OvEN - INSTALLED UNDEr COUNTEr

SINGLE wALL OvEN - CUTOUT DImENSIONS

(N) Minimum Cabinet Width

(P) Minimum Cut Out Width

(R) Minimum Cutout Height

30” (76.2 cm)

28 1/2” (72.4 cm)

26 7/8” (68.3 cm)

Minimum interior cabinet depth: 24” (61.0 cm)

Cabinet tolerances: +1/16” (+1.6 mm) -0, unless otherwise stated

Document # PG01-009 Revised 09/07/11 Page 2/2

1 1/2”(3.8 cm)

typical counter

1“ (2.5 cm) min.to combustible floor

3/4” (1.9 cm)support platform

1“ (2.5 cm) min. to combustibles

Recommendedelectricallocation

4” typical toe kick

36” typ.(91.4 cm) P

R

Recommendedelectricallocation

Alternateelectricallocation

4” typical toe kick

P

R3/4” (1.9 cm)

support platform

31 1/4” (79.4 cm)recommended

1” (2.5 cm) min.to bottom of cabinet door

1” (2.5 cm) min.to top of

cabinet door

N

Page 17: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.15

rO230, rOv230

30 Inch, Double, renaissance wall Oven

(A) Overall Width

(B) Chassis Width

(C) Overall Height

(D) Chassis Height

(E) Control Panel

Overlay29 7/8”

(75.9 cm)28 3/8”

(72.1 cm)49 7/8”

(126.7 cm)49”

(124.5 cm)7/8”

(2.2 cm)

(F) Utility Cutout Width

(G) Utility Cutout Height

(H) Utility Cutout Depth

(J) Control Panel Depth

(K) Chassis Depth

6 1/4”(15.9 cm)

4 3/4”(12.1 cm)

7 3/4”(19.7 cm)

1 3/16”(3.0 cm)

23 5/8”(60.0 cm)

ELECTRICAL SPECIFICATIONSDedicated Circuit

Requirements Total Connected Load

240 Vac 60 Hz., 4-wire,* 60 Amp. 11.6 kW (48.6 Amp.)

* Two 120 Vac hot (L1 and L2), one neutral, one ground. Fuse/circuit breaker on both L1 and L2.The above specifications are for reference only. See the product data plate for exact specifications.

Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated

Document # PG01-010 Revised 08/26/11 Page 1/2

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

21 1/8”

3 1/2”(8.9 cm)

3 3/16”(8.1 cm)

1 1/8”(2.9 cm)

1 1/8”(2.9 cm)

HANDLE DImENSIONS

Epicure Millennia (Order kit #AMOH30))

C

A

Conduit:60” (152 cm)

Long

D

J

B

H

G

F

Top of chassis

Utilitycutout

K

Control panelside view

Control panel front Top of

chassisE

Page 18: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.16

30 Inch, Double, renaissance wall Oven

rO230, rOv230

DOUBLE wALL OvEN - CUTOUT DImENSIONS

(N) Minimum Cabinet Width

(P) Minimum Cut Out Width

(R) Minimum Cutout Height

30” (76.2 cm)

28 1/2” (72.4 cm)

49 1/8” (124.8 cm)

Minimum interior cabinet depth: 24” (61.0 cm)

Cabinet tolerances: +1/16” (+1.6 mm) -0, unless otherwise stated

Document # PG01-010 Revised 08/26/11 Page 2/2

4” typical toe kick

Recommendedelectricallocation

N

P

R

3/4” (1.9 cm)support platform

1” (2.5 cm) min.to bottom of cabinet door

1” (2.5 cm) min.to top of

drawer face

9 5/8” (24.4 cm)recommended

Page 19: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 2.1

24”, 27”, 30”, 36”, wide warming Drawers

ErwD, EwD, IwD, mrwD, mwDv, mwDH, OwD

Document # PG02-002 Revised 01/24/11 Page 1/3

Drawer open

Chassis

5/64"(2 mm)

23 13/16”(60.5 cm)

23 3/8”(59.4 cm)

BC

OvErALL DImENSIONS - TOP vIEw(EwD SErIES SHOwN)

A

10 1/8”(257 mm)

DrAwEr FACE DImENSIONS(MWD SerieS ShoWn)

3 7/16"(8.7 cm)

EWD

3 1/4"(8.3 cm)

MWDH/V

1"(2.5 cm)

3 1/2"(8.9 cm)

MRWD30B(only)

All other MRWDseries

ERWD

1 1/8"(2.9 cm)

1 7/16"(3.7 cm)

1"(2.5 cm)

1"(2.5 cm)

HANDLE DImENSIONS - SIDE vIEw

CHASSIS DImENSIONS

10"(25.4 cm)

9"(22.9 cm)1/2" (1.3 cm)

1/2" (1.3 cm)

Chassis without drawer inserted

Mounting hole 9 places

40” (101.6 cm) 3-prong 120 Vac

power cord

Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated

wArmING DrAwEr OvErALL DImENSIONS

Model (A) Drawer Face Width

(B) Chassis Face Width

(C) Chassis Width

ERWD27 27” (68.6 cm) 26 5/8” (67.6 cm) 25 1/4” (64.1 cm)

ERWD30 30” (76.2 cm) 29 5/8” (75.2 cm) 28 1/4” (71.8 cm)

EWD24 24” (61.0 cm) 23 5/8” (60.0 cm) 22 1/4” (56.5 cm)

EWD27 27” (68.6 cm) 26 5/8” (67.6 cm) 25 1/4” (64.1 cm)

EWD30 30” (76.2 cm) 29 5/8” (75.2 cm) 28 1/4” (71.8 cm)

EWD36 36” (91.4 cm) 35 5/8” (90.5 cm) 34 1/4” (87.0 cm)

MRWD27 26 3/4” (67.9 cm) 26 5/8” (67.6 cm) 25 1/4” (64.1 cm)

MRWD30 29 3/4” (75.6 cm) 29 5/8” (75.2 cm) 28 1/4” (71.8 cm)

MWDH27 27” (68.6 cm) 26 5/8” (67.6 cm) 25 1/4” (64.1 cm)

MWDH30 30” (76.2 cm) 29 5/8” (75.2 cm) 28 1/4” (71.8 cm)

MWDV27 27” (68.6 cm) 26 5/8” (67.6 cm) 25 1/4” (64.1 cm)

MWDV30 30” (76.2 cm) 29 5/8” (75.2 cm) 28 1/4” (71.8 cm)

Electrical Circuit Required Total Connected Load Minimum Ambient Operating Temperature

120 Vac, 60 Hz, 15 Amp. grounded, dedicated circuit

4.0 Amp. @ 120 Vac, 60 Hz. 32°F (0°C)

Page 20: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 2.2

24”, 27”, 30”, 36”, wide warming Drawers

ErwD, EwD, IwD, mrwD, mwDv, mwDH, OwD

Document # PG02-002 Revised 01/24/11 Page 2/3

D

A

DrAwEr FACE DImENSIONS(iWD/oWD SerieS ShoWn)

Chassis

Drawer open F

E

5/16”(8 mm)

BC

OvErALL DImENSIONS - IwD/OwD SErIES TOP vIEw

CHASSIS DImENSIONS(iWD/oWD ShoWn)

40" (101.6 cm)3 prong

120 Vac power cord

Chassis withoutdrawer installed

Mounting hole,

** = OWD24 mounting holes

** **

** **

9 places

G

Model (A) Dimension Drawer Face Width

(B) Dimension Chassis Width

(C) Dimension Chassis Face

Width

(D) Dimension

Drawer Face Height

(E) Dimension

Chassis Depth

(F) Dimension

Drawer Depth

(G) Dimension

Chassis Height

IWD24 22 5/16” (56.7 cm) 22 1/4” (56.5 cm) 22 3/8” (56.8 cm)8 15/16” (22.7 cm)

23 3/8” (59.4 cm)

23 13/16” (60.5 cm)

9 1/16” (23.0 cm)IWD27 25 5/16” (64.3 cm) 25 1/4” (64.1 cm) 25 3/8” (64.5 cm)

IWD30 28 5/16” (71.9 cm) 28 1/4” (71.8 cm) 28 3/8” (72.1 cm)

OWD24 22 1/2” (57.1 cm) 22 1/2” (57.1 cm) 22 1/2” (57.1 cm) 11 7/8” (30.2 cm)

20” (50.8 cm)

18” (45.7 cm)

11 7/8” (30.2 cm)

Product tolerances: ±1/16” (±1.6 mm) unless otherwise statedElectrical Circuit Required Total Connected Load Minimum Ambient

Operating Temperature

120 Vac, 60 Hz, 15 Amp. grounded, dedicated circuit

4.0 Amp. @ 120 Vac, 60 Hz. 32°F (0°C)

Page 21: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 2.3

24”, 27”, 30”, 36” wide warming Drawers

ErwD, EwD, IwD, mrwD, mwDv, mwDH, OwDDocument # PG02-002 Revised 01/24/11 Page 3/3

Warmingdrawer

Cooktop1 1/2" (3.8 cm)Typical countertop

3/4” min.*(1.9 cm)

120 Vac electricaloutlet

A36" typ.

(91.4 cm)B

C

A

Warmingdrawer

Warmingdrawer

B

3/4" min.*(1.9 cm)

D

3/4" min.*(1.9 cm)

36" typ.(91.4 cm) 120 Vac

electricaloutlet

C

C

27"/30"/36" Dacorsingle wall oven

Warmingdrawer

Warmingdrawer

Toe kick

D

C

C

D

120 Vacelect.

120 Vacelect.

A3/4" min.*(1.9 cm)

Cabinet/countertop tolerances: +1/16” (+1.6 mm) -0 unless otherwise stated

* Bare minimum spacing to allow for ventilation and avoid scraping on ERWD, EWD, MRWD, MWDH and MWDV series models.** On IWD series models or OWD24 without the optional front panel kit: The chassis and the drawer faceplate are smaller than the cutout. The custom front panel mounts to the drawer faceplate. The height and width of the custom front panel must exceed the appropriate cutout dimensions (A and C above) to cover the hole. Allow 1/4" minimum additional space on the top, bottom and sides from the custom front panel edge to prevent scraping against adjacent doors, drawers and the countertop.*** OWD24 with optional factory front panel kit only. Bare minimum spacing shown to avoid scraping. Gap above and below cutout is 3/4” minimum. See ** above for OWD24 with custom front panel.**** Model EWD36 cannot be installed above or below another warming drawer (any type).***** Model OWD24 cannot be installed above, below or adjacent to a wall oven or warming drawer (any type).

Model (A) Cutout Width(B) Min. Width to Adjacent Doors/

Drawers(C) Cutout Height (D) Min. Vertical Gap

Between Cutouts Min. Cutout Depth

ERWD27 25 1/2” (64.8 cm) 27 1/4” (69.2 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*ERWD30 28 1/2” (72.4 cm) 30 1/4” (76.8 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*EWD24 22 1/2” (57.2 cm) 24 1/4” (61.6 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*

24” (61.0 cm)

EWD27 25 1/2” (64.8 cm) 27 1/4” (69.2 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*EWD30 28 1/2” (72.4 cm) 30 1/4” (76.8 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*EWD36**** 34 1/2” (87.6 cm) 36 1/4” (92.1 cm)* 9 1/8” (23.2 cm) NAIWD24 22 1/2” (57.2 cm) ** 9 1/8” (23.2 cm) 1 1/16” (2.7 cm)IWD27 25 1/2” (64.8 cm) ** 9 1/8” (23.2 cm) 1 1/16” (2.7 cm)IWD30 28 1/2” (72.4 cm) ** 9 1/8” (23.2 cm) 1 1/16” (2.7 cm)MRWD27 25 1/2” (64.8 cm) 27” (68.6 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*MRWD30 28 1/2” (72.4 cm) 30” (76.2 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*MWDH27 25 1/2” (64.8 cm) 27 1/4” (69.2 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*MWDH30 28 1/2” (72.4 cm) 30 1/4” (76.8 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*MWDV27 25 1/2” (64.8 cm) 27 1/4” (69.2 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*MWDV30 28 1/2” (72.4 cm) 30 1/4” (76.8 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*OWD24***** 22 5/8” (57.5 cm) 24 1/4” (61.6 cm)*** 11 15/16” (30.3 cm) NA 20 1/8” (51.1 cm)

WARNING• Observe all governing codes and ordinances

during planning and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

Mounting platform must be 3/4" (1.9 cm) thick and support 100 lbs.

Page 22: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 3.1

30 Inch and 36 Inch wide,millennia® Electric Cooktops

PrODUCT DImENSIONS - ETT365-2 AND mETB365-1 (ETT365-2 SHOwN)

36 1/4" *(921 mm)

34 3/8"(873 mm)

19 3/8" (495 mm)21 1/4" *

(540 mm)

4" (102 mm)Chassis height

30 1/4" *(768 mm)

28 3/8"(721 mm)19 3/8"

(495 mm)21 1/4" *(540 mm)

4" (102 mm)Chassis height

PrODUCT DImENSIONS - ETT304-1 AND mET304 (ETT304-1 SHOwN)

ETT304-1, ETT365-2, mET304 and mETB365-1

Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted

Document # PG03-001 Revised 05/06/10 Page 1/3

NOTES:1. The cooktop is supplied with a flexible, 48 inch long

power conduit consisting of two (2) insulated hot lead conductors (L1 and L2) and one (1) insulated ground conductor. There is no neutral connection. All leads are copper. The conduit is connected to the right corner of the cooktop. Do not connect the ground wire to neutral.

2. Tested in accordance with the latest edition of ANSI Z21.1 and U.L. 858 Standard for household cooking appliances.

3. These cooktops are not approved for recessed installation.

Model No. Electrical Circuit Required Total Connected Load*

Minimum Supply Wire Size Line and Ground Connections

ETT304-1 240 Vac, 60 Hz, 40 Amps. 6.9 kW (29 Amps.)

No. 8 AWGETT365-2 240 Vac, 60 Hz, 40 Amps. 9.1 kW (38 Amps.)

MET304 240 Vac, 60 Hz, 40 Amps. 6.9 kW (29 Amps.)

METB365-1 240 Vac, 60 Hz, 50 Amps.* 9.6 kW (40 Amps.)

* For reference only, See the product data label on bottom of unit for exact specifications.

ELECTrICAL SUPPLY rEqUIrEmENTS

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

* For units with stainless steel trim, other units may be up to 1/8" less.

Page 23: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 3.2

30 Inch and 36 Inch wide,millennia® Electric Cooktops

ETT304-1, ETT365-2, mET304 and mETB365-1

All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated

Document # PG03-001 Revised 05/06/10 Page 2/3

When installing model ETT365-2 or METB365-1 and the bottom of the chassis is to be enclosed wall to wall, you must install Dacor ventilation duct kit ATD323.

Allow a minimum of 6 inches (152 mm) clearance between the top of the countertop and any combustible surface below, including the upper edge of a drawer below the cooktop. Proper under-cabinet clearance is also required for the cooktop hold down brackets.

6” (152 mm)Min. clearanceto combustiblesurfacesA

6" (152 mm) Min. from mounting surface to combustibles belowcooktop chassis

B

Min. to combustible,side wall, both sides

Rearwall

1" Min.

19 3/4" Min.(502 mm)

6" (152 mm)(25 mm)

2 1/4" Min.(57 mm)

UNDEr COUNTEr CLEArANCE

Model (A) Minimum Under Counter Clearance (Width)

ETT304-1, MET304 30 1/2” (775 mm)

ETT365-2, METB365-1 36 1/2” (927 mm)

Model (B) Minimum Under Counter Clearance (Width)

ETT304-1, MET304 28 3/4” (730 mm)

ETT365-2, METB365-1 34 3/4” (883 mm)

COUNTErTOP CUTOUT (wITHOUT rAISED vENT)

3/4”

7 3/4” X 4 3/8”ventilationcut-outsinenclosurefloor

1 1/2” 1 1/2”3/4”

TOP vIEw vENTILATION CUTOUT

Cooktop cutout in top of cabinet

Page 24: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 3.3

30 Inch and 36 Inch wide,millennia® Electric Cooktops

Stiffener

Cabinet face

Countertop

Floor

3/8” Min. (10 mm) space behind raised vent chassis to clear stiffener

3/8” Min. (10 mm)flat countertop overhangrequired behind cutout

ERV or PRV series raised vent: Check raised vent dimensions/specifications to determine proper fit

ETT or MET series cooktop

19 3/4"(502 mm)

6" Min.(152 mm)

6" Min.(152 mm)

1" Min.(25 mm)

Cabinetface

A

B

C

D E

6" (152 mm) Min. from mounting surface to combustibles belowcooktop chassis

Rearwall

Stiffener

Cabinet face

Countertop

Floor

5/8” Min. (16 mm) space behind raised vent chassis to clear stiffener

5/8” Min. (16 mm)flat countertop overhangrequired behind cutout

RV series raised vent: Check raised vent dimensions/specifications to determine proper fit

ETT or MET series cooktop

Erv AND Prv SErIES rAISED vENT INSTALLATION SIDE vIEw

rv SErIES rAISED vENT INSTALLATION SIDE vIEw

COUNTErTOP CUTOUT (wITH rAISED vENT) TOP vIEw

COUNTErTOP CUTOUT (wITH rAISED vENT) ISO vIEw

ETT304-1, ETT365-2, mET304 and mETB365-1

All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated

Document # PG03-001 Revised 05/06/10 Page 3/3

Model/Configuration (A) Cooktop Cutout Width

(B) Raised Vent Cutout Width

(C) Total Cutout Depth

(D) Raised Vent Cutout Depth

(E) Minimum Rear Countertop

OverhangETT304-1 or MET304 cooktop with ERV30 or PRV30 raised vent 28 3/4”

(730 mm)27 3/4”

(705 mm)

22 1/2”(572 mm)

2 3/4”(70 mm)

3/8”(10 mm)

ETT304-1 or MET304 cooktop withRV30 raised vent

22 1/4”(565 mm)

2 1/2”(64 mm)

5/8”(16 mm)

ETT365-2 or METB365-1 cooktop with ERV36 or PRV36 raised vent 34 3/4”

(883 mm)33 3/4”

(857 mm)

22 1/2”(572 mm))

2 3/4”(70 mm)

3/8”(10 mm)

ETT365-2 or METB365-1 cooktop with RV36 raised vent

22 1/4”(565 mm)

2 1/2”(64 mm)

5/8”(16 mm)

Page 25: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.1

A

EG366, EG486

ELECTrIC CIrCUIT rEqUIrEmENTS

Circuit Required Total Connected Load

120 Vac 60Hz, 15 Amp. (3 wire) 0.25 Amp @ 120 Vac, 60 Hz

GAS SUPPLY PrESSUrE rEqUIrEmENTS*

Gas Type Manifold Pressure Minimum Gas Supply Pressure

Natural Gas 5” Water Column 6” Water Column

Propane (LP) 10” Water Column 11” Water Column

* Maximum gas supply pressure for all models is 1/2 p.s.i.

IMPORTANT: Installation of a non-combustible material* (up to the hood) or a backsplash is always recommended, and mandatory if the distance to the back wall from the cooktop is less than 2 1/2” (Figure 2). When installing a backguard, use only Dacor model numbers AEB3609, AEB3612 (EG366), AEB4809 or AEB4812 (EG486).

CABINET/COUNTErTOP SIDE vIEw wITHOUT BACkGUArD

CABINET/COUNTErTOP SIDE vIEw wITH BACkGUArDPrODUCT DImENSIONS - SIDE vIEw

PrODUCT DImENSIONS - ISO vIEw

A - WidthEG366 35 7/8” (911 mm)

EG486 47 7/8” (1216 mm)

Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

Document # PG04-001 Revised 05/06/10 Page 1/4

4” (102 mm)5/8”

(16 mm)

7 3/4” (197 mm)

Trim:7/16”

(11 mm)thick26” (660 mm)

1 1/2” (38 mm) cooking surface height (grate level) above

countertop

3/4” gas inlet, connects to regulator from bottom or rear of unit, end is recessed

2” (51 mm) from chassis bottom

27” (686 mm)

28” (711 mm)

Power cord32” long

Combustiblerear wall

Backguard mandatory ifgap from back of cooktopto combustible wall is lessthan 2 1/2”

Combustiblerear wall

2 1/2” (64 mm) Min. tocombustible rear wall

36 Inch and 48 Inch wideEpicure® Gas Cooktops

Page 26: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.2

See note 2

2 See Cabinet/Countertop Dimensions - Top View 3 Not applicable for cabinets more than a horizontal distance of 10” (254mm) from the edge of the cooktop.

1 Vertical to combustible surface from cooktop grate level;if installing an overhead vent hood, also check the hoodspecifications for minimum required clearances.

C

13” (330 mm) max.3

Top offinishedcounter

18” (457 mm)Min.1, 3

30” (762 mm)Min.1 Cutout for

utility access

Hood

Recommendedgas and electricalservice location,

consult local code

B

10” (254 mm) tocombustible side

wall Min. both sides 1/2” (13 mm)overhang,both sides

1 1/2” (38 mm)typical countertop

thickness

7 3/4” (197 mm)

36” (914 mm)typical

Cooktop platform1” (25 mm) Min.

thickness

Model No. B C

EG366 36” (914 mm) 36” (914 mm)* 42” (1067 mm)**

EG486 48” (1219mm) 48” (1219 mm)* 54” (1372 mm)**

* Minimum ** Recommended

Cabinet tolerances: +1/16”, -0 (+1.6 mm, -0) unless otherwise noted.

CABINET/COUNTErTOP DImENSIONS - FrONT vIEw

CABINET/COUNTErTOP DImENSIONS -ISO vIEw

Continued on following pages...

EG366, EG486Document # PG04-001 Revised 05/06/10 Page 2/4

36 Inch and 48 Inch wideEpicure® Gas Cooktops

Page 27: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.3

CABINET/COUNTErTOP CUTOUT DImENSIONS wITHOUT rAISED vENT - TOP vIEw

Model No. B - Cutout Width D - Hole OffsetEG366 36” (914 mm) 16 5/8” (422 mm)

EG486 48” (1219 mm) 20 13/16” (529 mm)

Cutout tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated

EG366, EG486Document # PG04-001 Revised 05/06/10 Page 3/4

Non-combustible rear wall, rear of

mounting platform

10” (254 mm) min. to combustible wall above countertop,

both sides

Cabinet face below countertop

overhang

Increase countertop and overhang additional 2 1/2” (64 mm) Min. for

combustible rear wall above countertop

3/8” (13 mm) countertop overhang

Hole 1/2” dia. (13 mm), 2 places, through platform

for hold down bolts

Gas/electrical utility cut-out in right rear corner of mounting platform 8” W X 6” D (203 mm X 152 mm),

if gas and electrical are routed through bottom1/2” (13 mm) countertop overhang

1” thick mounting platform Min.

Cou

nter

top

Countertop

1/2” (13 mm) countertop overhang

2” (51 mm)1” (25 mm)

11 7/16” (291 mm)

24 5/8” (625 mm)

CL

D D

B

CL CLCL

Gas connection and power cord may be routed through bottom or back of chassis

Gas and electrical connections at right rear section of chassis

36 Inch and 48 Inch wideEpicure® Gas Cooktops

Page 28: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.4

CABINET/COUNTErTOP CUTOUT DImENSIONS wITH rAISED vENT - TOP vIEw

CABINET/COUNTErTOP CUTOUT DImENSIONS wITH rAISED vENT - SIDE vIEw

EG366, EG486Document # PG04-001 Revised 05/06/10 Page 4/4

Model No.

B - Cutout Width

D - Hole Offset

E - Raised Vent Cutout

EG366 36” (914 mm)

16 5/8” (422 mm)

33 1/2” (851 mm)

EG486 48” (1219 mm)

20 13/16” (529 mm)

43 1/2” (1105 mm)

Model No.

Approved RaisedVent Models

EG366 ERV36, PRV36

EG486 ERV48, PRV48

Cutout tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated

Non combustible rear wall recommended 10” (254 mm) Min. to

combustible wall above countertop,

both sides

Cabinet face below countertop

overhang

3/8” (10 mm) Min. countertop overhang

2 5/8”(67 mm)

Hole 1/2” dia. (13 mm), 2 places, through platform

for hold down bolts

1/2” (13 mm) countertop overhang

1” thick mounting platform Min.

Open to below to allow for raised vent, gas and electrical connections

Cou

nter

top

Countertop

1/2” (13 mm) countertop overhang

2” (51 mm)1” (25 mm)

11 7/16” (291 mm)

15”(381 mm)

24 5/8”(625 mm)

CL

D D

E

B

CL CLCL

Stiffener

Cabinet face

Control panel

Countertop

Dacor approvedraised vent

IMPORTANT: See raised ventinstallation instructions for duct system layout/planning

EG366 or EG486 cooktop

3/8” Min. (10 mm)space behindraised vent chassis to clearstiffener

3/8” Min. (10 mm)flat countertop overhangrequired behind cutout

Minimumcountertop

height: 30 1/4"

(768 mm)

IMPORTANT: Use only the raised vents specified.

36 Inch and 48 Inch wideEpicure® Gas Cooktops

Page 29: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.5

SGm304, SGm365, SGm466

30”, 36”, 46” wide,Drop-in Gas Cooktops

30"(76.2 cm)

1 5/8" (4.1 cm)bottom of base

to cooking surface

27 5/8" *(70.2 cm)

* including embosses/screws in side of chassis

19 1/2" * (49.5 cm)21"

(53.3 cm)

4" (10.2 cm)chassis height

36"(91.4 cm)

33 1/2" *(85.1 cm)

* including embosses in side of chassis

19 1/2" * (49.5 cm)21"

(53.3 cm)

1 5/8" (4.1 cm)bottom of base

to cooking surface

4" (10.2 cm)chassis height

* including embosses/screws in side of chassis

46"(116.8 cm)

44 5/8" *(113.3 cm)

19 1/2" * (49.5 cm)21"

(53.3 cm)

1 5/8" (4.1 cm)bottom of base

to cooking surface

4" (10.2 cm)chassis height

All tolerances ±1/16” (±1.6 mm), unless otherwise noted.

PrODUCT DImENSIONS - mODEL SGm304

PrODUCT DImENSIONS - mODEL SGm365

PrODUCT DImENSIONS - mODEL SGm466

Document # PG04-004 Revised 01/27/11 Page 1/5

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

Page 30: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.6

SGm304, SGm365, SGm466

Electrical Requirements

WARNINGTo prevent an electric shock hazard, the power supply must meet the specifications stated below. It is the owner’s responsibility to make sure that the electrical service meets electrical require-ments and that the electrical outlet has been properly installed.◊ The cooktop is supplied with a factory installed, 40-inch, three-prong,

grounding electrical plug. It is connected to the chassis at the bottom right rear corner (see Chassis Bottom Diagram below). It must be connected to a dedicated, grounded three-prong electrical outlet installed by a licensed electrician.

◊ The electrical installation, including minimum supply wire size and grounding, must be done in accordance with National Electric Code ANSI/NFPA 70* and local codes and ordinances. A copy of this standard may be obtained from:

National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101

◊ The correct voltage, frequency and amperage must be supplied to the electrical outlet according to the product data label located on the bottom of the chassis. See the Gas and Electrical Requirements table on this page for reference.

◊ Be certain to locate the electrical outlet so that the power cord may be easily disconnected if the unit needs service.

Gas Supply Requirements◊ Be certain that the cooktop being installed is correct for the gas

service being provided (natural gas or LP gas). Also, if operating the cooktop at an altitude above 4000 ft. (1219 m) make sure it is equipped for high altitude operation.

◊ Units equipped for LP operation have “LP” in the model number listed on the product data label. See the Chassis Bottom Diagram for label location.

◊ Units equipped for high altitude operation have an “H” at the end of the model number listed on the product data label.

◊ Check your local building codes for the proper method of installation. In the absence of local codes, this appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54.

◊ An external manual shut-off valve must be installed between the gas inlet and the cooktop for the purpose of turning on or shutting off gas to the appliance.

◊ The cooktop comes from the factory with a regulator in the shipping carton. Use only the regulator provided. The regulator must be installed in the gas line that runs from the cooktop gas inlet to the gas shut off valve.

◊ Models SGM304 and SGM365 come with a 1/2” regulator. Model SGM466 comes with a 3/4” regulator, approved for connection to a 1/2” house gas supply.

The cooktop gas connection is located on the bottom of the cootktop in the back right corner as you face the front of the unit. See the Chassis Bottom Diagram on this page.

SGM304 SGM365 SGM466

SGM304LP SGM365LP SGM466LP

Gas type Natural LPG

Manifold pressure 4” Water column 10” Water column

Min. gas supply pressure** 5” Water column 11” Water column

Max. gas supply pressure 1/2 p.s.i. 1/2 p.s.i.

Total connected load 0.25 Amp.(0.03 kW)

0.25 Amp.(0.03 kW)

Circuit requirement 120 Vac,60 Hz, 15 Amp.

120 Vac,60 Hz, 15 Amp.

GAS AND ELECTrICAL rEqUIrEmENTS*

* The electrical and gas data on this page is for reference only. If the above data does not agree with the product data label, use the data on the product data label.** The gas supply pressure for testing the regulator setting shall be at least 1 inch water column (249 Pa) above the specified manifold pressure.

CHASSIS BOTTOm DIAGrAm

Front of unit

Product data label

Electric cordGas inlet

Document # PG04-004 Revised 01/27/11 Page 2/5

30”, 36”, 46” wide,Gas Cooktops

Page 31: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.7

SGm304, SGm365, SGm466

◊ Allow a minimum 1/4” (6 mm) clearance between the bottom of the cooktop chassis and all combustible surfaces, including the upper edge of a drawer installed below the cooktop.

Model (B) Minimum*

SGM304 29” (73.7 cm)

SGM365 35 1/4” (89.5 cm)

SGM466 46” (116.8 cm)

* To allow clearance for hold down brackets

◊ The gas supply piping, gas shut-off valve and the electrical outlet must be located so they do not interfere with the cooktop when it is installed. If installing another appliance in the cabinet below, allow for the routing of gas and electrical service behind it.

The installation must allow for the following:

◊ Access to the gas shut-off valve and regulator when the unit is installed.

◊ Access to the electrical outlet when the cooktop is in place. The 40” (101.6 cm) power cord must be able to reach the electrical outlet

◊ Access to the underside of the cooktop for service and inspection purposes

◊ Clearance inside the cabinet to allow for proper hold down bracket installation.

To allow access to the utilities and cooktop bottom, a fixed shelf should not be installed below the cooktop. See the following pages for countertop cutout dimensions.

Raised Vent CompatibilityIf installing the cooktop with a raised vent, install only the approved Dacor model numbers specified below:

Cooktop Models Approved Raised Vent Models

SGM304 ERV30, PRV30 or RV30

SGM365 ERV36, PRV36 or RV36

SGM466 PRV46 or RV46

Cabinet and Countertop Layout

WARNING• To reduce the risk of personal injury caused by reaching over

a hot appliance, avoid locating cabinet storage space directly above the cooktop.

• Failure to meet or exceed the maximum and minimum dimensions/clearances stated in these instructions may result in a fire hazard.

• Follow the countertop manufacturer’s instructions regarding the minimum corner radius, use of heat reflective tape, reinforcement of corners, etc.

◊ Carefully check the location where the cooktop will be installed. For best performance, the cooktop should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets.

◊ This appliance is to be used in conjunction with a suitable vent hood or approved Dacor raised vent system.

mINImUm rEqUIrED CLEArANCES ArOUND THE COOkTOP

Model (A) Minimum (A) Recommended

SGM304 30” (76.2 cm) 36” (91.4 cm)

SGM365 36” (91.4 cm) 42” (106.7 cm)

SGM466 48” (121.9 cm) 54” (137.2 cm)

1/4” (6 mm)min. clearanceto combustiblesurfacesB

Under Cabinet Clearances

13" max.3

(33.0 cm)

3 Not applicable for cabinets more than a horizontal distance of 6” (15.2 cm) from edge of cooktop. Allow 7 1/2” (19.1 cm) from edge of cutout.

A

See cutoutdimensions

18" min.1, 3

(45.7 cm)

1 7/8" min. (4.8 cm)

Combustible surface to rear

Combustible overhead cabinets

30" min.1, 2

(76.2 cm)

7 1/2” (19.1 cm) min. to combustible side wall,above counter both sides

2 If installing with an overhead vent hood, also check hood specifications for minimum required clearances.

1 Measured from cooking surface (top of cooktop grate).

Cabinet tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated

Document # PG04-004 Revised 01/27/11 Page 3/5

30”, 36”, 46” wide,Gas Cooktops

Page 32: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.8

SGm304, SGm365, SGm466

Cutout tolerances +1/16” (+1.6 mm), -0, unless otherwise noted

Countertop Dimensions

Installation Type Cutout Diagram (C) Min. (D) (E) (F) (G) (H)

SGM304 without raised vent

Figure 1(Square)

2 7/8”(7.3 cm)

19 3/4” (50.2 cm)

27 3/4”(68.6 cm) NA NA NA

SGM304 with ERV30 or PRV30

Figure 1(Square)

3/8”(1.0 cm)

22 1/2” * (57.2 cm)

27 3/4”(68.6 cm) NA NA NA

SGM304 with RV30

Figure 1(Square)

5/8”(1.6 cm)

22 1/4” * (56.5 cm)

27 3/4”(68.6 cm) NA NA NA

SGM365 without raised vent

Figure 1(Square)

2 7/8”(7.3 cm)

19 3/4” (50.2 cm)

33 5/8”(85.4 cm) NA NA NA

SGM365 with ERV36 or PRV36

Figure 1(Square)

3/8”(1.0 cm)

22 1/2” * (57.2 cm)

33 5/8”(85.4 cm) NA NA NA

SGM365 with RV36

Figure 1(Square)

5/8”(1.6 cm)

22 1/4” * (56.5 cm)

33 5/8”(85.4 cm) NA NA NA

SGM466 without raised vent

Figure 1(Square)

2 7/8”(7.3 cm)

19 3/4” (50.2 cm)

44 3/4”(113.7 cm) NA NA NA

SGM466 with PRV46

Figure 2(Notched)

3/8”(1.0 cm)

22 1/2” * (57.2 cm)

44 3/4”(113.7 cm)

43 1/2”(110.5 cm)

5/8”(1.6 cm)

2 5/8” **(6.7 cm)

SGM466 with RV46

Figure 2(Notched)

5/8”(1.6 cm)

22 1/4” * (56.5 cm)

44 3/4”(113.7 cm)

43 1/2”(110.5 cm)

5/8”(1.6 cm)

2 5/8” **(6.7 cm)

Stiffener

Cabinet face

Countertop

Floor

3/8” min. (1.0 cm) space behind raised vent chassis to clear stiffener

3/8” min. (1.0 cm)flat countertop overhangrequired behind cutout

ERV or PRV series raised vent: Check raised vent dimensions/specifications to determine proper fit

SGM series cooktopStiffener

Cabinet face

Countertop

Floor

5/8” min. (1.6 cm) space behind raised vent chassis to clear stiffener

4 5/8” (11.7 cm)9 7/8” (25.1 cm) with CABP3 blower installed

5/8” min. (1.6 cm)flat countertop overhangrequired behind cutout

RV series raised vent: Check raised vent dimensions/specifications to determine proper fit

SGM series cooktop

Cutout Dimensions

SIDE vIEw - SGm SErIES COOkTOP wITHErv Or Prv SErIES rAISED vENT

SIDE vIEw - SGm SErIES COOkTOP wITHrv SErIES rAISED vENT

IMPORTANT: Be careful to use the correct cutout diagram (on page 5/5) to determine the countertop dimensions for the installation type. Carefully double check all dimensions against the table below and the correct diagram before cutting the countertop.

* Total cutout depth, accommodates both the cooktop and raised vent ** IMPORTANT: Notch depth is included in total cutout depth (D). DO NOT add notch depth to total cutout depth (D).

Document # PG04-004 Revised 01/27/11 Page 4/5

30”, 36”, 46” wide,Gas Cooktops

Page 33: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.9

SGm304, SGm365, SGm466

4 1/4" (10.8 cm) min. from mounting surface to combustibles belowcooktop chassis

EC

D

7 1/2" (19.1 cm) min.to combustibleside wall abovecountertop(both sides)

Verticalcombustiblesurface

Rearwall

1 7/8" min.(4.8 cm)

EC

D

H

H

GF

7 1/2" (19.1 cm) min.to combustibleside wall abovecountertop(both sides)

Verticalcombustiblesurface

Rearwall

1 7/8" min.(4.8 cm)

4 1/4" (10.8 cm) min. from mounting surface to combustiblesbelow cooktop chassis

FIGUrE 1 - SqUArE COUNTErTOP CUTOUT DIAGrAm

FIGUrE 2 - NOTCHED COUNTErTOP CUTOUT DIAGrAm

Document # PG04-004 Revised 01/27/11 Page 5/5

30”, 36”, 46” wide,Gas Cooktops

Cutout tolerances +1/16” (+1.6 mm), -0, unless otherwise noted

Page 34: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.10

rGC304, rGC365

30"(76.2 cm)

2 1/8" (5.4 cm)bottom of base

to cooking surface

27 1/2" *(69.9 cm)

* including embosses in side of chassis

19 1/2" * (49.5 cm)21"

(53.3 cm)

4" (10.2 cm)chassis height

PrODUCT DImENSIONS - mODEL rGC304

Axis2Axis2

36"(91.4 cm)

2 1/8" (5.4 cm)bottom of base

to cooking surface

33 5/8" *(85.4 cm)

* including embosses in side of chassis

19 1/2" * (49.5 cm)

21"(53.3 cm)

4" (10.2 cm)chassis height

PrODUCT DImENSIONS - mODEL rGC365

All tolerances ±1/16” (±1.6 mm) unless otherwise noted.

Document # PG04-005 Revised 01/25/11 Page 1/4

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

30”, 36” wide renaissance Gas Cooktops

Page 35: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.11

Electrical Requirements

WARNINGTo prevent an electric shock hazard, the power supply must meet the specifications stated below. It is the owner’s responsibility to make sure that the electrical service meets electrical require-ments and that the electrical outlet has been properly installed.◊ The cooktop is supplied with a factory installed, 40-inch power cord

with a, three-prong, grounding electrical plug. It is connected to the chassis at the bottom right rear corner (see Chassis Bottom Diagram below). It must be connected to a dedicated, grounded three-prong electrical outlet installed by a licensed electrician.

◊ The electrical installation, including minimum supply wire size and grounding, must be done in accordance with National Electric Code ANSI/NFPA 70* and local codes and ordinances. A copy of this standard may be obtained from:

National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101

◊ The correct voltage, frequency and amperage must be supplied to the electrical outlet according to the product data label located on the bottom of the chassis. See the Gas and Electrical Requirements table on this page for reference.

◊ Be certain to locate the electrical outlet so that the power may be easily disconnected if the unit needs service.

Gas Supply Requirements◊ Be certain that the cooktop being installed is correct for the gas

service being provided (natural gas or LP gas). Also, if operating the cooktop at an altitude above 4000 ft. (1219 m) make sure it is equipped for high altitude operation.

◊ Units equipped for LP operation have “LP” in the model number listed on the product data label. See the Chassis Bottom Diagram for label location.

◊ Units equipped for high altitude operation have an “H” at the end of the model number listed on the product data label.

◊ Check your local building codes for the proper method of installation. In the absence of local codes, this appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54.

◊ An external manual shut-off valve must be installed between the gas inlet and the cooktop for the purpose of turning on or shutting off gas to the appliance.

◊ The cooktop comes from the factory with a regulator in the shipping carton. Use only the regulator provided. The regulator must be installed in the gas line that runs from the cooktop gas inlet to the gas shut off valve.

◊ The regulator inlet accommodates a 3/4” gas line. The inlet to the cooktop itself is equipped with a 3/4” male NPT fitting.

The cooktop gas connection is located on the bottom of the cootktop in the back right corner as you face the front of the unit. See the Chassis Bottom Diagram on this page.

RGC304 RGC365

RGC304LP RGC365LP

Gas type Natural LPG

Manifold pressure 5” Water column 10” Water column

Min. gas supply Pressure** 6” Water column 11” Water column

Max. gas supply pressure 1/2 p.s.i. 1/2 p.s.i.

Total connected load 0.25 Amp.(0.03 kW)

0.25 Amp.(0.03 kW)

Circuit requirement 120 Vac,60 Hz, 15 Amp.

120 Vac,60 Hz, 15 Amp.

GAS AND ELECTrICAL rEqUIrEmENTS*

* The electrical and gas data on this page is for reference only. If the above data does not agree with the product data label, use the data on the product data label.** The gas supply pressure for testing the regulator setting shall be at least 1 inch water column (249 Pa) above the specified manifold pressure.

rGC304, rGC365

CHASSIS BOTTOm DIAGrAm

Front of unit

Product data label

Electric cordGas inlet

Document # PG04-005 Revised 01/25/11 Page 2/4

30”, 36” wide, renaissance Gas Cooktops

Page 36: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.12

Cabinet and Countertop Layout

WARNING• To reduce the risk of personal injury caused by reaching over

a hot appliance, avoid locating cabinet storage space directly above the cooktop.

• Failure to meet or exceed the maximum and minimum dimensions/clearances stated in these instructions may result in a fire hazard.

• Follow the countertop manufacturer’s instructions regarding the minimum corner radius, use of heat reflective tape, reinforcement of corners, etc.

◊ Carefully check the location where the cooktop will be installed. For best performance, the cooktop should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets.

◊ This appliance is to be used in conjunction with a suitable vent hood or approved Dacor raised vent system.

mINImUm rEqUIrED CLEArANCES ArOUND THE COOkTOP

Model (A) Min. (A) Recommended

RGC304 30” (76.2 cm) 36” (91.4 cm)

RGC365 36” (91.4 cm) 42” (106.7 cm)

◊ Allow a minimum 1/4” (6 mm) clearance between the bottom of the cooktop chassis and all combustible surfaces, including the upper edge of a drawer installed below the cooktop.

Model (B) Min.*

RGC304 29” (73.7 cm)

RGC365 35 1/4” (89.5 cm)

* To allow clearance for hold down brackets

◊ The gas supply piping, gas shut-off valve and the electrical outlet must be located so they do not interfere with the cooktop when it is installed. If installing another appliance in the cabinet below, allow for the routing of gas and electrical service behind it.

The installation must allow for the following:

◊ Access to the gas shut-off valve and regulator when the unit is installed.

◊ Access to the electrical outlet when the cooktop is in place. The 40” (101.6 cm) power cord must be able to reach the electrical outlet

◊ Access to the underside of the cooktop for service and inspection purposes

◊ Clearance inside the cabinet to allow for proper hold down bracket installation.

To allow access to the utilities and cooktop bottom, a fixed shelf should not be installed below the cooktop. See the following pages for countertop cutout dimensions.

Raised Vent CompatibilityIf installing the cooktop with a raised vent, install only the approved Dacor model numbers specified below:

Cooktop Model Approved Raised Vent Models

RGC304 ERV30, PRV30 or RV30

RGC365 ERV36, PRV36 or RV36

rGC304, rGC365

1/4” (6 mm)min. clearanceto combustiblesurfacesB

Under Cabinet Clearances

13" max.3

(33.0 cm)

3 Not applicable for cabinets more than a horizontal distance of 6” (15.2 cm) (5 1/2” (14.0 cm) for RGC365) from edge of cooktop. Allow 7 1/2” (19.1 cm) from cutout edge for RGC304 and 7” (17.8 cm) for RGC365.

A

18" min.1, 3

(45.7 cm)

1 7/8" min. (4.8 cm)

Combustible surface to rear

Combustible overhead cabinets

30" min.1, 2

(76.2 cm)

See cutout dimensions

See cutoutdimensions

2 If installing with an overhead vent hood, also check the hood specifications for minimum required clearances.

1 Measured from the cooking surface (top of cooktop grate).

All tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated

Document # PG04-005 Revised 01/25/11 Page 3/4

30”, 36” wide, renaissance Gas Cooktops

Page 37: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.13

rGC304, rGC365

4 1/4" (10.8 cm) min. from mounting surface to combustibles belowcooktop chassis

E

F

C

D

Min. distance to combustible side wall above countertop (both sides)

F

Verticalcombustiblesurface

Rearwall

1 7/8" min.(4.8 cm)

Installation Type (C) Min. (D) (E) (F)RGC304 with no raised vent 2 7/8” (7.3 cm) 19 3/4” (50.2 cm)

27 5/8” (70.1 cm) 7 1/2” (19.0 cm)RGC304 with ERV30 or PRV30 3/8” (1.0 cm) 22 1/2” (57.2 cm)

RGC304 with RV30 5/8” (1.6 cm) 22 1/4” (56.5 cm)

RGC365 with no raised vent 2 7/8” (7.3 cm) 19 3/4” (50.2 cm)

33 3/4” (85.7 cm) 7” (17.8 cm)RGC365 with ERV36 or PRV36 3/8” (1.0 cm) 22 1/2” (57.2 cm)

RGC365 with RV36 5/8” (1.6 cm) 22 1/4” (56.5 cm)

COUNTErTOP CUTOUT DImENSIONS

Stiffener

Cabinet face

Countertop

Floor

3/8” min. (1.0 cm) space behind raised vent chassis to clear stiffener

3/8” min. (1.0 cm)flat countertop overhangrequired behind cutout

ERV or PRV series raised vent: check raised vent dimensions/specifications to determine proper fit

RGC series cooktopStiffener

Cabinet face

Countertop

Floor

5/8” min. (1.6 cm) space behind raised vent chassis to clear stiffener

5/8” min. (1.6 cm)flat countertop overhangrequired behind cutout

RV series raised vent: check raised vent dimensions/specifications to determine proper fit

RGC series cooktop

All tolerances: +1/16” (+1.6 mm), -0, unless otherwise statedCutout Dimensions

SIDE vIEw - rGC SErIES COOkTOP wITHErv/Prv SErIES rAISED vENT

SIDE vIEw - rGC SErIES COOkTOP wITHrv SErIES rAISED vENT

Document # PG04-005 Revised 01/25/11 Page 4/4

30”, 36” wide, renaissance Gas Cooktops

Page 38: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.14

A

30” and 36” wide, Distinctive Series Slide-in Gas Cooktops

DrT304S, DrT366S

ELECTRIC CIRCUIT REQUIREMENTS

Circuit Required Total Connected Load

120 Vac 60Hz, 15 Amp. (3 wire) 1.0 Amp @ 120 Vac, 60 Hz.

GAS SUPPLY PRESSURE REQUIREMENTS*

Gas Type Manifold Pressure Minimum Gas Supply Pressure

Natural Gas 5” Water Column 6” Water Column

Propane (LP) 10” Water Column 11” Water Column

* Maximum gas supply pressure for all models is 1/2 p.s.i.

Installation of a non-combustible material* (up to the hood) or a backsplash is always recommended, and mandatory if the distance to the back wall from the cooktop is less than 2 1/2” (Figure 2). When installing a backguard, use only Dacor model numbers AEB3009 (DRT304S), AEB3609 or AEB3612 (DRT366S).

SIDE vIEw wITHOUT BACkGUArD

SIDE vIEw wITHOUT BACkGUArD

SIDE vIEw

Product Dimensions

Electrical and Gas Supply Requirements

Cabinet and Countertop Layout

COOKTOP WIDTH (A)DRT304S 29 7/8” (75.9 cm)

DRT366S 35 7/8” (91.1 cm)

Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

Document # PG04-003 Revised 02/03/11 Page 1/4

4” (10.2 cm) 5/8” min. (1.6 cm)

7 3/4” (19.7 cm)

Trim:1/2”

(1.3 cm)thick25 7/8” (65.7 cm)

1 5/8” (4.1 cm) cooking surface height (grate level) above

countertop

3/4” gas inlet, connects to regulator from bottom or rear of unit, end is recessed

2” (5.1 cm) from chassis bottom

28 1/8” (71.4 cm)

Power cord32” (81.3 cm) long

Combustiblerear wall

Backguard mandatory ifgap from back of cooktopto combustible wall is lessthan 2 1/2”

Combustiblerear wall

2 1/2” (6.4 cm) min. tocombustible rear wall

Page 39: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.15

See note 2

2 See Cabinet/Countertop Dimensions - Top View 3 Not applicable for cabinets more than a horizontal distance of 10” (25.4 cm) from the edge of the cooktop.

1 Vertical to combustible surface from cooktop grate level;if installing an overhead vent hood, also check the hoodspecifications for minimum required clearances.

C

13” (33.0 cm) max.3

Top offinishedcounter

18” (45.7 cm)min.1, 3

30” (76.2 cm)min.1 Cutout for

utility access

Hood

Recommendedgas and electricalservice location,

consult local code

B

10” (25.4 cm) tocombustible side

wall min. both sides 1/2” (1.3 cm)overhang,both sides

1 1/2” (3.8 cm)typical countertop

thickness

7 3/4” (19.7 cm)

36” (91.4 cm)typical

Cooktop platform1” (2.5 cm) min.

thickness

Model No. B C

DRT304S 30” (76.2 cm) 30” (76.2 cm)* 36” (91.4 cm)**

DRT366S 36” (91.4 cm) 36” (91.4 cm)* 42” (106.7 cm)**

* Minimum ** Recommended

Cabinet tolerances: +1/16”, -0 (+1.6 mm, -0) unless otherwise noted.

CABINET/COUNTErTOP DImENSIONS - FrONT vIEw

CABINET/COUNTErTOP DImENSIONS -ISO vIEw

Continued. on following page...

Cabinet and Countertop Layout (Continued)

DrT304S, DrT366SDocument # PG04-003 Revised 02/03/11 Page 2/4

NOTE: Model DRT304S is not approved for installation with a raised vent.

30” and 36” wide, Distinctive Series Slide-in Gas Cooktops

Page 40: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.16

DrT304S, DrT366S

CABINET/COUNTErTOP CUTOUT DImENSIONS wITHOUT rAISED vENT - TOP vIEw

Model No. B - Cutout Width D EDRT304S 30” (76.2 cm) 13 3/8” (34.0 cm) 10 1/8” (25.7 cm)

DRT366S 36” (91.4 cm) 16 5/8” (42.2 cm) 11 3/16” (28.4 cm)

Cutout tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated

Document # PG04-003 Revised 02/03/11 Page 3/4

Cabinet and Countertop Layout (Continued)

Non-combustible rear wall, rear of

mounting platform

10” (25.4 cm) min. to combustible wall above countertop,

both sides

Cabinet face below countertop

overhang

Increase countertop and overhang additional 2 1/2” (6.4 cm) min. for

combustible rear wall above countertop

3/8” (1.3 cm) countertop overhang

Hole 1/2” dia. (1.3 cm), 2 places, through platform

for hold down bolts

Gas/electrical utility cut-out in right rear corner of mounting platform 8” W X 6” D (20.3 cm X 15.2 cm),

if gas and electrical are routed through bottom1/2” (1.3 cm) countertop overhang

1” thick mounting platform min.

Cou

nter

top

Countertop

1/2” (1.3 cm) countertop overhang

2” (5.1 cm)1” (2.5 cm)

E

24 5/8” (62.5 cm)

D D

B

CL

Gas connection and power cord may be routed through bottom or back of chassis

Gas and electrical connections at right rear section of chassis

30” and 36” wide, Distinctive Series Slide-in Gas Cooktops

Page 41: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.17

Stiffener

Cabinet face

Control panel

Countertop

Use Dacor raisedvent, model ERV3615 only IMPORTANT: See raised vent

installation instructions for duct system layout/planning

DRT366 cooktop

3/8” min. (1.0 cm)space behindraised vent chassis to clearstiffener

3/8” min. (1.0 cm)flat countertopoverhang required behind cutout

Minimumcountertop

height: 30 1/4"

(76.8 cm)

28 5/16” (71.9 cm)

Non combustible rear wall recommended 10” (2.5 cm) min. to

combustible wall above countertop,

both sides

Cabinet face below countertop

overhang

3/8” (1.0 cm) min. countertop overhang

2 5/8”(6.7 cm)

Hole 1/2” dia. (1.3 cm), 2 places, through platform

for hold down bolts

1/2” (1.3 cm) countertop overhang

1” (2.5 cm) thick mounting platform min.

Open to below to allow for raised vent, gas and electrical connections

Cou

nter

top

Countertop

1/2” (1.3 cm) countertop overhang

2” (5.1 cm)1” (2.5 cm)

15”(38.1 cm)

24 1/2”(62.2 cm)

D

E

D

F

B

CLCABINET/COUNTErTOP CUTOUT DImENSIONS wITH rAISED

vENT - TOP vIEw

CABINET/COUNTErTOP CUTOUT DImENSIONS wITH rAISED

vENT - SIDE vIEw

Model No.*

B - Cutout Width D E F - Raised

Vent Cutout

DRT366S 36” (91.4 cm)

16 5/8” (42.2 cm)

11 3/16” (28.4 cm)

33 1/2” (85.1 cm)

* Model DRT304 is not approved for use with a raised vent. ** Use only raised vent model specified. Raised vent is not compatible with DRT cooktops having a serial number starting with letters “SA.”

Cutout tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated

DrT304S, DrT366SDocument # PG04-003 Revised 02/03/11 Page 4/4

Cabinet and Countertop Layout (Continued)

30” and 36” wide, Distinctive Series Slide-in Gas Cooktops

NOTE: Gas and electrical connections may only be routed through the bottom of the cooktop when installed with a raised vent.

Page 42: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.18

DCT305, DCT365

A2" (5.1 cm)countertop

to cooking surface

21"(53.3 cm)

4" (10.2 cm)chassis height

Product Dimensions

Front of unit

Power cord 42” (106.7 cm) long

1/2” maleNPT gas inlet

2”(5.1 cm)

1 3/4”(4.4 cm)

1/2” male NPT gas inlet*

Power cord in

Chassis

Front of cooktop

Top panel overhang

*Gas inlet protudes 1/2” (1.3 cm) from bottom

1 3/4”(4.4 cm)

UTILITY LOCATIONS UTILITY DImENSIONS

Product tolerances ±1/16” (±1.6 mm) unless otherwise noted.

Document # PG04-006 Revised 08/19/11 Page 1/4

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

30” and 36” wide, Distinctive Series Drop-in Gas Cooktops

Side View

Rearoverhang

Frontoverhang

19 9/32” (49.0 cm)

17/32”(1.3 cm)

1 3/16”(3.0 cm)

Front View

B

1 11/32”(3.4 cm)

1 11/32”(3.4 cm)

Model (A) (B)DCT305 30” (76.2 cm) 27 5/16” (69.4 cm)

DCT365 36” (91.4 cm) 33 5/16” (57.8 cm)

Page 43: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.19

Electrical Requirements

WARNINGTo prevent an electric shock hazard, the power supply must meet the specifications stated below. It is the owner’s responsibility to make sure that the electrical service meets electrical require-ments and that the electrical outlet has been properly installed by a licensed electrician.◊ The cooktop is supplied with a factory installed, 42 inch power cord

with a, three-prong, grounding electrical plug. It is connected to the chassis at the bottom right rear corner (see Chassis Bottom Diagram below). It must be connected to a dedicated, grounded three-prong electrical outlet installed by a licensed electrician.

◊ The electrical installation, including minimum supply wire size and grounding, must be done in accordance with National Electric Code ANSI/NFPA 70* and local codes and ordinances. A copy of this standard may be obtained from:

National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101

◊ The correct voltage, frequency and amperage must be supplied to the electrical outlet according to the product data label located on the bottom of the chassis. See the Gas and Electrical Requirements table on this page for reference.

◊ Be certain to locate the electrical outlet so that the power may be easily disconnected if the unit needs service.

Gas Supply Requirements◊ Be certain that the cooktop being installed is correct for the gas

service being provided (natural gas or LP gas). Also, if operating the cooktop at an altitude above 4000 ft. (1219 m) make sure it is equipped for high altitude operation.

◊ Units equipped for LP operation have “LP” in the model number listed on the product data label. See the Chassis Bottom Diagram for label location.

◊ Units equipped for high altitude operation have an “H” at the end of the model number listed on the product data label.

◊ Check your local building codes for the proper method of installation. In the absence of local codes, this appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54.

◊ An external manual shut-off valve must be installed between the gas inlet and the cooktop for the purpose of turning on or shutting off gas to the appliance.

◊ The cooktop comes from the factory with a regulator in the shipping carton. Use only the regulator provided. The regulator must be installed in the gas line that runs from the cooktop gas inlet to the gas shut off valve.

◊ The regulator inlet accommodates a 3/4” gas line. The inlet to the cooktop itself is equipped with a 3/4” male NPT fitting.

The cooktop gas connection is located on the bottom of the cootktop in the back right corner as you face the front of the unit. See the Chassis Bottom Diagram on this page.

DCT304_NG DCT365_NG

DCT304_LP DCT365_LP

Gas type Natural LP gas

Manifold pressure 5” water column 10” water column

Min. gas supply Pressure** 6” water column 11” water column

Max. gas supply pressure 1/2 psi 1/2 psi

Total connected load 0.25 Amp.(30 Watts)

0.25 Amp.(30 Watts)

Circuit requirement 120 Vac,60 Hz, 15 Amp.

120 Vac,60 Hz, 15 Amp.

GAS AND ELECTrICAL rEqUIrEmENTS*

* The electrical and gas data on this page is for reference only. If the above data does not agree with the product data label, use the data on the product data label.** The gas supply pressure for testing the regulator setting shall be at least 1 inch water column (249 Pa) above the specified manifold pressure.

DCT305, DCT365

CHASSIS BOTTOm DIAGrAm

Front of unit

Product data label

Document # PG04-006 Revised 08/19/11 Page 2/4

30” and 36” wide, Distinctive Series Drop-in Gas Cooktops

Page 44: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.20

Cabinet and Countertop Layout

WARNING• To reduce the risk of personal injury caused by reaching over

a hot appliance, avoid locating cabinet storage space directly above the cooktop.

• Failure to meet or exceed the maximum and minimum dimensions/clearances stated in these instructions may result in a fire hazard.

• Follow the countertop manufacturer’s instructions regarding the minimum corner radius, use of heat reflective tape, reinforcement of corners, etc.

◊ Carefully check the location where the cooktop will be installed. For best performance, the cooktop should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets.

◊ This appliance is to be used in conjunction with a suitable vent hood or approved Dacor raised vent system.

mINImUm rEqUIrED CLEArANCES ArOUND THE COOkTOP

Model (A) Minimum (A) RecommendedDCT305 30” (76.2 cm) 36” (91.4 cm)

DCT365 36” (91.4 cm) 42” (106.7 cm)

◊ Allow a minimum 1/4” (6 mm) clearance between the bottom of the cooktop chassis and all combustible surfaces, including the upper edge of a drawer installed below the cooktop.

Model (B) MinimumDCT305 29 1/4” (74.3 cm)

DCT365 35 1/4” (89.5 cm)

◊ The gas supply piping, gas shut-off valve and the electrical outlet must be located so they do not interfere with the cooktop when it is installed. If installing another appliance in the cabinet below, allow for the routing of gas and electrical service behind it.

The installation must allow for the following:

◊ Access to the gas shut-off valve and regulator when the unit is installed.

◊ Access to the electrical outlet when the cooktop is in place. The 42” (106.7 cm) power cord must be able to reach the electrical outlet

◊ Access to the underside of the cooktop for service and inspection purposes

◊ Clearance inside the cabinet to allow for proper hold down bracket installation.

To allow access to the utilities and cooktop bottom, a fixed shelf should not be installed below the cooktop. See the following pages for countertop cutout dimensions.

Raised Vent CompatibilityModel DCT305 is not compatible with a raised vent. If installing cooktop model DCT365 with a raised vent, install only Dacor raised vent model ERV3615. Installation of any other raised vent model may cause improper operation.

DCT305, DCT365

1/4” (6 mm)mimimum clearanceto combustiblesurfaces

B

* Allows for clearance between hold down brackets

13” max.3

(33.0 cm)

3 This specification does not apply for cabinets located greater than a horizontal distance of 5 1/2” (14.0 cm) from edge of cooktop. Allow 6 7/8” (17.5 cm) from cutout edge.

A

1 5/8” min. (4.1 cm)

Combustible surface to rear

30” min.1, 2

(76.2 cm)

See cutoutdimensions

See cutoutdimensions

2 If installing with an overhead range hood, check the hood specifications for minimum required clearances.

1 Distance to combustible surfaces measured from cooking surface (top of cooktop grate).

18” min.1, 3

(45.7 cm)

Cabinet tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated

Document # PG04-006 Revised 08/19/11 Page 3/4

30” and 36” wide, Distinctive Series Drop-in Gas Cooktops

Page 45: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.21

DCT305, DCT365

4 1/4” (10.8 cm) min. from mounting surface to combustibles belowcooktop chassis

E

F

C

D

Minimum distance to combustible side wall above countertop (both sides)

F

Verticalcombustiblesurface

Rearwall

1 5/8” min.(4.1 cm)

Installation Type (C) Minimum (D) (E) (F) MinimumDCT305* 3 1/4” (8.3 cm) 19 5/8” (49.9 cm) 27 5/8” (85.4 cm)

6 7/8” (17.5 cm)DCT365 with no raised vent 3 1/4” (8.3 cm) 19 5/8” (49.9 cm)33 5/8” (85.4 cm)

DCT365 with ERV3615 raised vent 3/8” (1.0 cm) 22 3/4” (57.8 cm)

* Model DCT305 is not compatible with a raised vent

Stiffener

Cabinet face

Countertop

Floor

3/8” min. (1.0 cm) space behind raised vent chassis to clear stiffener

3/8” min. (1.0 cm)flat countertop overhangrequired behind cutout

ERV3615 raised vent.Check raised vent dimensions/specifications to determine proper fit

DCT365 cooktop

Cabinet tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated

Cutout Dimensions

SIDE vIEw - DCT365 COOkTOP wITH Erv3615 rAISED vENT

Document # PG04-006 Revised 08/19/11 Page 4/4

30” and 36” wide, Distinctive Series Drop-in Gas Cooktops

Raised Vent CompatibilityIf installing cooktop DCT365 with a raised vent, install only Dacor raised vent model ERV3615. Installation other any other model raised vent may cause improper operation.

Page 46: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.1

Er30G, Er30GI

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

All tolerances ±1/16” (±1.6mm) unless otherwise noted.

1 1/8” (29mm)

1 9/16”(40mm)

2” (51mm)

3” (76mm)

Front of open doorFront of handleFront edge of bullnoseFront panelRear of front panel

Backguard thickness

26 1/8” (664mm)27 1/16” (687mm)28 9/16” (725mm)

24” (610mm)

3” (76mm)Backguard***

ER30G:Full stainless

steel side panels

ER30GI:Partial stainless steel side panel

Grates extend1” above trim

6” (152mm)Backguard*

1 3/4” (44mm) Backguard**

***

**

*

Optional on both models, NOT compatible with self-rimming installations

Standard on model ER30GOptional on model ER30GI, NOTcompatible with self-rimming installations Standard on model ER30GIOptional on model ER30G

Product width:29 7/8” (759mm)

ER30G is designed for freestanding install-ations. ER30GI is designed for installation in a recessed cabinet or island. ER30G is NOT equipped for self-rimming installation.

NOTE: Neither model is compatible with a raised vent.

35”(889mm)

to37 1/8”

(943mm)

9” (229mm)Backguard***

45 9/16” (1157mm)

Er30G/Er30GI OvErALL DEPTH DImENSIONS - SIDE vIEw

Electrical Circuit Required

Total Connected Load

120 Vac, 60 Hz, 15 Amps., dedicated, grounded

4.0 Amps. @ 120 Vac, 60 Hz

ELECTrICAL rEqUIrEmENTS

Document # PG05-001 Revised 05/25/10 Page 1/3

30” wide, Epicure®

All Gas range

Page 47: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.2

Er30G, Er30GI

All tolerances +1/16” -0 (+1.6mm, 0) unless otherwise noted.

A* B C

30 1/16” (764mm) 30” (762mm) Minimum36” (914mm) Recommended

37 1/8” (943mm) Maximum

Note 2

2 Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See product dimesions. 3 Consult local code for exact location requirements.4 Not applicable for cabinets more than a horizontal distance of 10” (254mm) from the edge of the range.

1 Vertical to combustible surface from range grate level

B

A

Non-combustible surface along back wallrecommended

10” (254mm Min.to combustible sidewalls above the range(both sides)

Top offinishedcounter

Suggested location of utilities3

30” (762mm)Min.1

13” (330mm)Max.4

18” (457mm)Min.1, 4

C

SLIDE-IN CUTOUT DImENSIONS

SELF-rImmING CUTOUT DImENSIONS - CABINET DEPTH GrEATEr THAN 24 INCHES

(Er30GI ONLY)

SELF-rImmING CUTOUT DImENSIONS - CABINET DEPTH ExACTLY 24 INCHES

(Er30GI ONLY)

non comubustible rear wall recommended

Countertop Height: Min: 34 3/4” (883mm) Max: 36 7/8” (937mm) Countertop Thickness: Max: 1 5/8” (41mm)

countertop opening29 1/4” (743mm)

30” (762mm)cabinet openingbelow countertop

below countertopCabinet face

Notch countertopoverhang to width of

cabinets

10” Min. (254mm)to any combustibles above counter both sides

Countertop overhang 2 1/8” (54mm) Max.

24” (610mm)

rear wall orcountertop edge

Countertop Height: Min: 34 3/4” (883mm) Max: 36 7/8” (937mm) Countertop Thickness: Max: 1 5/8” (41mm)

countertop opening29 1/4” (743mm)

30” (762mm)cabinet openingbelow countertop

below countertopCabinet face

Notch countertopoverhang to width of

cabinets

3/4” Min. (19mm) Countertop overhang

10” Min. (254mm)to any combustibles above counter both sides

Countertop overhang 2 1/8” (54mm) Max.

24 1/8” (613mm)

* See the cutout dimensions below for self-rimming installations

Document # PG05-001 Revised 05/25/10 Page 2/3

NOTE: Self-rimming kit is included with model ER30GI. The self-rimming kit allows the trim to overlap the counter top on the sides and back.

30” wide, Epicure®

All Gas range

Page 48: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.3

Er30G, Er30GI

12 1/2”(318 mm)

to14 5/8”

(371 mm)2 5/8”

(67 mm)CL

CL10” (

254m

m)

10” (

254m

m)

12” (305mm)

2 1/2”(64mm)

3 1/2”(89mm)

1” (25mm)

BACk OF rANGE UTILITY CLEArANCE BEHIND rANGE

GAS SUPPLY PRESSURE REQUIREMENTSGas Type

Manifold Pressure* (WC)

Min. Gas Supply Pressure (WC)

Max. Input Pressure

Natural 5” 6” 1/2 p.s.i.LP 10” 11” 1/2 p.s.i.

IMPORTANT: The information above is for reference only. If the above data does not agree with the product data label, use the data on the product data label on top of the kick plate below the door (remove the door according to the installation instructions to view it).The gas connection is located on the back of the unit as shown. Use a 1/2" male NPT to connect to the regulator.

Document # PG05-001 Revised 05/25/10 Page 3/3

30” wide, Epicure®

All Gas range

Page 49: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.4

36” wide, Epicure®

Gas range

Er36G, Er36GIDocument # PG05-002 Revised 05/25/10 Page 1/3

WARNING• Observe all governing codes and ordinances during

planning and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

All tolerances ±1/16” (±1.6 mm) unless otherwise noted.

1 9/16”(40 mm)

2” (51 mm)1

3” (76 mm)

Front of open doorFront of handleFront edge of bull noseFront panelRear of front panel7

26 3/4” (679 mm)27 13/16” (706 mm)29” (736 mm)

24 5/8” (625 mm)

ER36G:Full stainless

steel side panels

ER36GI:Partial stainless steel side panel

Grates extend1” above trim

Product Width: 35 7/8” (911 mm)

35 3/4”(908 mm)

to37 7/8”

(962 mm)

46 7/8” (1191 mm)

1 1/4” (32 mm)

15 1/4” (387 mm)

A

BC

D19” (482 mm)

9” (229 mm)

(A) 1 3/4” (44 mm): Model AER36GLBG (low profile) 2 (B) 6” (152 mm): Model AER36GBG6 3, 5

(C) 9” (229 mm): Model AER36GBG9 4, 5

(D) 24” (610 mm): Model AER36GBG24 4, 5

Er36G/Er36GI DImENSIONS SIDE vIEw

Er36G/Er36GI AvAILABLE BACkGUArDS

Electrical Circuit Required

Total Connected Load

120 Vac, 60 Hz, 15 Amp. grounded, dedicated, 3 prong

electrical outlet

5.0 Amps. @120 Vac, 60 Hz,

ELECTrICAL rEqUIrEmENTS

NOTES:1. Trim thickness is 1/4” (6 mm) with optional self-rimming kit

installed (ER36GI only).2. Standard on model ER36GI. Optional on model ER36G.3. Standard on model ER36G. Optional on model ER36GI.4. Optional on both models.5. Not for use with self rimming installations. ER36G is not

equipped for self-rimming installation.6. ER36G is designed for freestanding installations. ER36GI is

designed for installation in a recessed cabinet or island.7. This dimension is shortened to 24 inches when the self-

rimming kit is installed (ER36GI only).

NOTE: Neither model is compatible with raised vents.

Page 50: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.5

Er36G, Er36GI

All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.

NOTES:1. Utilities may be located in the lower left corner

of the adjacent right cabinet (recommended). Consult local code.

2. Self-rimming kit is included with model ER36GI. The self-rimming kit allows the trim to overlap the counter top on the sides and back. ER36G is not equipped for self-rimming installation.

A * B C

36 1/16” (916 mm) 30” (762 mm) Minimum36” (914 mm) Recommended

37 7/8” (962 mm) Maximum

Note 2

2 Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See product dimesions. 3 Consult local code for exact location requirements.4 Not applicable for cabinets more than a horizontal distance of 10” (254mm) from the edge of the range.

1 Vertical to combustible surface from range grate level

B

A

Non-combustible surface along back wallrecommended

10” (254mm Min.to combustible sidewalls above the range(both sides)

Top offinishedcounter

Suggested location of utilities3

30” (762mm)Min.1

13” (330mm)Max.4

18” (457mm)Min.1, 4

C

CABINET CUTOUT DImENSIONS

SELF-rImmING CUTOUT DImENSIONS - CABINET DEPTH GrEATEr THAN 24 INCHES

(Er36GI ONLY)

SELF-rImmING CUTOUT DImENSIONS - CABINET DEPTH ExACTLY 24 INCHES

(Er36GI ONLY)

non comubustible rear wall recommended

Countertop Height: Min: 35 1/2” (902 mm) Max: 37 5/8” (956 mm) Countertop Thickness: Max: 1 5/8” (41mm)

countertop opening35 1/4” (895 mm)

36” (914 mm)cabinet openingbelow countertop

below countertopCabinet face

Notch countertopoverhang to width of

cabinets

10” Min. (254mm)to any combustibles above counter both sides

Countertop overhang 2 1/8” (54 mm) Max.

24” (610mm)

rear wall orcountertop edge

Countertop Thickness: Max: 1 5/8” (41mm)

countertop opening

cabinet openingbelow countertop

below countertopCabinet face

Notch countertopoverhang to width of

cabinets

3/4” Min. (19mm) Countertop overhang

10” Min. (254mm)to any combustibles above counter both sides

Countertop overhang 2 1/8” (54mm) Max.

24 1/8” (613mm)

Countertop Height: Min: 35 1/2” (902 mm) Max: 37 5/8” (956 mm)

35 1/4” (895 mm)

36” (914 mm)

* See the Cutout dimensions below for self-rimming installations

Document # PG05-002 Revised 05/25/10 Page 2/3

36” wide, Epicure®

Gas range

Page 51: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.6

CL

CL12 1

/2” (

318

mm

)

15” (

381

mm

)

12” (305mm)

2 1/2”(64mm)

3 1/2”(89mm)

1” (25mm)

Er36G, Er36GI

15 7/8”(403 mm)

to18”

(457 mm)3 3/4”

(95 mm)

BACk OF rANGE

GAS SUPPLY PRESSURE REQUIREMENTSGas Type

Manifold Pressure* (WC)

Min. Gas Supply Pressure (WC)

Max. Input Pressure

Natural 5” 6” 1/2 p.s.i.LP 10” 11” 1/2 p.s.i.

Document # PG05-002 Revised 05/25/10 Page 3/3

IMPORTANT: The information above is for reference only. If the above data does not agree with the product data label, use the data on the product data label on top of the kick plate below the door (remove the door according to the installation instructions to view it).The gas connection is located on the back of the unit as shown. Use a 1/2" male NPT to connect to the regulator.

UTILITY CLEArANCE BEHIND rANGE

36” wide, Epicure®

Gas range

Page 52: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.7

Epicure® ranges

Er30D, Er30DSr

ELECTRIC CIRCUIT REQUIREMENTS

Range Model Circuit RequiredTotal Connected

Load

ER30D/ER30DSR 240 Vac, 4-wire* 60 Hz, 30 Amp. 5.6 kW (24.2 Amp.)

The ratings above are for reference only - refer to the range rating label

NOTE: Models ER30D and ER30D-C are NOT designed for use with self-rimming installations or raised vents. Use model ER30DSR for self-rimming and raised vent installations.

NOTE:

■ Self-rimming models are designed to allow the trim to overlap the countertop when configured to the dimensions on page 1/3.

■ Self-rimming models are not compatible with integral backguards

1 9/16”(40 mm)

23 1/8” (587 mm)24 1/8” (613 mm)

27 3/16” (691 mm)

35 3/4”(908 mm)

to37 7/8”

(962 mm)

28 11/16” (729 mm)46 1/8” (1172 mm)

Rear of front panel to back of chassis

Rear of front panel /oven doorFront panelFront edge of bullnoseFront of handleFront of open door

26 3/16” (665 mm)

Width at front panel: 29 7/8” (758 mm)

1 5/16” (33 mm) to cookingsurface (top of grates) frombottom of trim

SELF rImmING mODEL Er30DSr SIDE DImENSIONS

wITH OPTIONAL rAISED vENT TrIm kIT INSTALLED (ATk30Sr)

1 1/16” (27 mm)

26 5/16” (668 mm)27 5/16” (694 mm)

28 13/16” (732 mm)

24 1/4” (616 mm)

3” (76 mm)Backguard*

6” (152 mm)Backguard**

** Optional Standard*

37 7/8”(962 mm)

to

35 3/4”(908 mm)

46 1/4” (1175 mm)

Width at front panel: 29 7/8” (758 mm)

Finished side panel

9” (229 mm)

1 9/16” (40 mm)

Backguard**

1 1/16” (27 mm) to cookingsurface (top of grates) fromtop of trim

FrEESTANDING mODELS Er30D AND Er30D-C

1 9/16”(40 mm)

23 1/8” (587 mm)23 5/8” (600 mm)

26 11/16” (678 mm)

35 3/4”(908 mm)

to37 7/8”

(962 mm)

28 3/16” (716 mm)45 5/8” (1159 mm)

Rear of front panel to back of chassis

Rear of front panel /oven doorFront panelFront edge of bullnoseFront of handleFront of open door

25 11/16” (652 mm)

Width at front panel: 29 7/8” (758 mm)

1 5/16” (33 mm) to cookingsurface (top of grates) frombottom of trim

SELF rImmING mODEL Er30DSrSIDE DImENSIONS

wITH STANDArD TrIm

Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated

WARNING• Observe all governing codes and ordinances during

planning and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

Document # PG05-003 Revised 02/03/11 Page 1/3

* 4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground

Page 53: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.8

Epicure® ranges

Er30D, Er30DSr

Note 2

F

G

2 Cabinet/countertop depth is at discretion of customer but cabinet face MUST NOT protrude further than rear of front panel, see product dimensions.3 Consult local code for exact location requirements.

1 Vertical to combustible surface from range grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances.

Non-combustible surface along

back wallrecommended

10” (254 mm) Min.to combustible sidewalls above the range(both sides)

30” (762 mm)Min.1

36 1/2” (927 mm)

Max.

13” (330 mm)Max.4

18” (457 mm)Min.1, 4

Suggested location of utilities

3

4 Not applicable for cabinets more than a horizontal distance of 10” (254 mm) from the edge of the range.

CUT-OUT DIMENSIONSF G

36” (914 mm)* 30” (762 mm)** 30 1/16” (916 mm)*

* Recommended ** Minimum

Gas and Electrical Service ■ The shaded area (diagram bottom left) denotes the location of

the gas inlet and the electrical junction box/receptacle. This is the recommended location. For replacement purposes, the location of the existing utilities may be utilized provided they do not interfere with the sides or rear of the range. Check local building codes for permissible gas valve and electrical locations.

■ An external manual shut-off valve must be installed between the gas inlet and the range, for the purpose of turning on or shutting off gas to the appliance.

The installation must allow for the following: ■ Access to the gas shut-off valve when the unit is installed.

■ Access to the remote circuit breaker panel/fuse box, when the range is in place.

■ The gas supply piping and shut-off valve, and the electrical junction box/receptacle must be located so they do not interfere with the range when it is installed.

■ The junction box and gas shut off valve must be located so that the range can be pulled out for service while the appliance remains connected.

CABINET CUTOUT DImENSIONS mODELS Er30D AND Er3OD-C

NOTE: See following page for countertop/cabinet cutout dimensions for self-rimming installations

Cabinet tolerances: +1/16”, (+1.6 mm) -0

GAS SUPPLY PRESSURE REQUIREMENTS*

Gas Type Manifold Pressure Minimum Gas Supply Pressure

Natural Gas 5” Water Column 6” Water Column

Petroleum (LP) 10” Water Column 11” Water Column

* Maximum input gas supply pressure for all models is 1/2 p.s.i.

GAS - ELECTRICAL ACCESS DIMENSIONS

A B C D E

4 7/8”(124 mm)

21 3/4”(552 mm)

8 5/8”(219 mm)

10 3/16”(259 mm)

7/8”*(22 mm)

* The hole size can be increased to 1 1/8” by removing the conduit bracket inside the range electrical access box.

B

Gas inlet

AC

7/8” (22 mm) Dia. electrical connection hole in bottom*

D

Range electrical access, cover removed

BACk OF rANGE

Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated

Document # PG05-003 Revised 02/03/11 Page 2/3

Page 54: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.9

Epicure® ranges

Er30D, Er30DSr

ER30DSR with H J K

no side panels no raised vent 23 1/2” (597 mm) 23 1/2” (597 mm) 24” to 25 9/16”

3-inch side panels* and no raised vent 20 1/2” (521 mm) 20 1/2” to 23 1/2” 21” to 25 9/16”

no side panels and raised vent 24” (610 mm) 24” (610 mm) 24 1/2” to 26 1/16”

3-inch side panels and raised vent 21” (533 mm) 21” to 24” 21 1/2” to 26 1/16”

Cutout tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated

TOP vIEw - mODEL Er30DSr COUNTErTOP/CABINET CUTOUT DImENSIONS SELF rImmING INSTALLATION

Non-combustiblerear wall recommeded

Countertop Height: Min: 35 5/8” (905 mm) Max: 37 3/8” (949 mm)

Combustible sidewall above range

countertop opening29 1/2” (749 mm)

30” (762 mm)cabinet openingbelow countertop

below countertopCabinet face

Notch countertopoverhang to width of

cabinets

1/4” Min. (6 mm) Countertopoverhang

10” Min.(254 mm)both sides

Countertop front

H J K

rear wall recommendedNon-combustible

countertop opening

cabinet openingbelow countertop

29 1/2” (749 mm)

27 1/2” (699 mm)

30” (762 mm)

2 3/8” (60 mm)

Combustible sidewall above range

10” Min.(254 mm)both sides

Countertop Height: Min: 35 5/8” (905 mm) Max: 37 1/4” (946 mm)

Notch countertopoverhang to width of

cabinets

3/8” Min. (10 mm)Countertopoverhang

below countertopCabinet face

raised vent opening

H J K

Countertop front

TOP vIEw - mODEL Er30DSr COUNTErTOP/CABINET CUTOUT DImENSIONS, SELF rImmING INSTALLATION wITH rAISED vENT (ATk30Sr TrIm kIT INSTALLED)

APPrOvED rAISED vENTS: Erv30 Or Prv30

Stiffener Cabinet face*

Countertop*

* IMPORTANT: See Countertop/Cabinet Cutout Dimensions for countertop cutout dimensions.

** IMPORTANT: If optional 3-inch side panels are not installedcabinet face must be flush with back of control panel.

Back ofcontrolpanel

ERV30 orPRV30raised vent

ER30DSR range: ATK30SR trim kit required for installationwith raised vent

3/8” Min. (10 mm)space behindraised vent chassis to clearstiffener

3/8” Min. (10 mm)flat countertopoverhang required behind cutout

Shown withoptional 3-inchside panelsinstalled**

Countertop height:35 5/8" (905 mm) Min.37 1/4” (946 mm) Max.

28 3/4” (730 mm)

Document # PG05-003 Revised 02/03/11 Page 3/3

Page 55: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.10

Epicure® ranges

Er36D, Er48D

GAS - ELECTRICAL ACCESS DIMENSIONS

Model A B C D E*

ER36D 5 5/8” (142.9 mm)

18 3/8” (466.7 mm)

10 3/4” (273.0 mm)

13 11/16” (347.7 mm)

7/8” (22.2 mm)

ER48D 3 13/16” (96.8 mm)

18 11/16” (474.7 mm)

9 3/8” (238.1 mm)

13 3/4” (349.3 mm)

1 1/8” (28.6 mm)

* The diameter on models equipped for use in Canada is ¼” (6.4mm) larger than those stated. Canadian units come from the factory pre-wired with an appliance cord. When installing an appliance cord on models that are not pre-wired, the hole size must be increased to 1 1/8” (1 3/8” for model ER48D) by removing the conduit bracket inside the range electrical access box.

48” (1219 mm) Front of open doorFront of handleFront edge of bull noseFront panelRear of front panel/oven door

30 3/4” (781 mm)

(483 mm)

(908 mm)

(940 mm)

(76 mm)

24” (610 mm)(51 mm)

(387 mm)

(40 mm)

(229 mm)

(229 mm)

29 3/8” (746 mm)28 1/4” (718 mm)26 1/8” (664 mm)

**

**

**

** Optional

1 1/16” (27 mm) to cookingsurface (top of grates) fromtop of trim

Finished sidepanel

Width: ER36D - 35 7/8” (911 mm) ER48D - 47 7/8” (1216 mm)

B

A

C

D

Gas regulator access, cover removed

Range electrical access, cover removed

E Electrical connection hole in bottom

InletBack of range

Product tolerances: +/- 1/16” (+/- 1.6 mm) unless otherwise stated

GAS SUPPLY PRESSURE REQUIREMENTS*

Gas Type Manifold Pressure Minimum Gas Supply Pressure

Natural Gas 5” Water Column 6” Water Column

Propane (LP) 10” Water Column 11” Water Column

* Maximum gas supply pressure 1/2 p.s.i. for all models

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

ELECTRIC CIRCUIT REQUIREMENTS

Range Model Circuit Required Total Connected Load

ER36D240 Vac, 4-wire* 60 Hz, 30

Amp. (Min.) 40 Amp. (Recommended)

6.5 kW (28 Amp.)

ER48D 240 Vac, 4-wire* 60 Hz, 50 Amp. 10.0 kW (42 Amp.)

* 4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground

Document # PG05-004 Revised 04/21/10 Page 1/2

OVEN INTERIOR SPECIFICATIONSModel Number Dimensions Volume

ER36D 15" H x 29" W x 19 ½" D 4.9 ft3

ER48D - Small oven 15" H x 15" W x 19 ½" D 2.5 ft3

ER48D - Large oven 15" H x 27" W x 19 ½" D 4.6 ft3

Page 56: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.11

Epicure® ranges

Er36D, Er48D

CUT-OUT DIMENSIONSRange Model F G H

ER36D 42” (1067 mm)* 36” (914 mm)**

36 1/16” (916 mm)**

33 1/2” (848 mm)

ER48D 54” (1372 mm)* 48” (1219 mm)**

48 1/16” (1221 mm)**

43 1/2” (1102 mm)

* Recommended **Minimum

Gas and Electrical Service ■ For replacement purposes, the location of the existing utilities may

be utilized provided they do not interfere with the sides or rear of the range. Check local building codes for permissible locations.

■ An external manual shut-off valve must be installed between the gas inlet and the range, for the purpose of turning on or shutting off gas to the appliance.

The installation must allow for the following:

■ Access to the gas shut-off valve when the unit is installed.

■ Access to the remote circuit breaker panel/fuse box, when the range is in place.

■ The gas supply piping and shut-off valve, and the electrical junction box/receptacle must be located so they do not interfere with the range when it is installed.

■ The junction box and gas shut off valve must be located so that the range can be pulled out for service while the appliance remains connected.

Note 2

F

G

2 Cabinet/countertop depth is at discretion of customer but cabinet face MUST NOT protrude further than rear of front panel, see product dimensions.3 Consult local code for exact location requirements.

1 Vertical to combustible surface from range grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances.

Non-combustible surface along

back wallrecommended

10” (254 mm) Min.to combustible sidewalls above the range(both sides)

30” (762 mm)Min.1

36 1/2” (927 mm)

Max.

13” (330 mm)Max.4

18” (457 mm)Min.1, 4

Suggested location of utilities

3

4 Not applicable for cabinets more than a horizontal distance of 10” (254 mm) from the edge of the range.

G

10" (254 mm) Min.to combustible sidewalls above the range(both sides)

non-combustible

Minumum Countertop Height:30 1/4” (768 mm) Maximum Countertop Height:36 1/2” (927 mm)

rear wall recommended

Backsplash

3/8" (10 mm)Min. flat countertop

overhang

H

2 13/16"(71.4 mm)

3

CUTOUT wITH OPTIONAL Erv rAISED vENT (TOP vIEw)

APPROVED RAISED VENT MODELS

Raised Vent Model For Use With Range Model

ERV36-ER ER36D

ERV48-ER ER48D

Stiffener Cabinet face**

Countertop*

* IMPORTANT: See “CUTOUT WITH OPTIONAL ERV RAISED VENT” for countertop cutout dimensions.

** IMPORTANT: Cabinet face must not stick out further thanback of control panel.

Back ofcontrolpanel

ERV36-ER orERV48-ERraised vent

ER36D or ER48D Range

3/8” Min. (10 mm)space behindraised vent chassis to clearstiffener

3/8” Min. (10 mm)flat countertop overhangrequired behind cutout

Countertop height:30 1/4" (768 mm) Min.36 1/2” (927 mm) Max.

rAISED vENT INSTALLATION SIDE vIEw

Cutout tolerances: +1/16” (+1.6 mm), -0 unless otherwise stated

Document # PG05-004 Revised 04/21/10 Page 2/2

Page 57: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.12

30 Inch wide millennia® Electric range

mrES30

PrODUCT DImENSIONS - ISO vIEw

35”(88.9 cm)

5/16” - 1 13/16”8 mm - 46 mm)

Removable (factory installed)3” (7.6 cm) side panels

Optional full size side panels(ARSL30S, ARSR30S)

60” (152.4 cm) long240 Vac 4 wireconduit location

Door opened

Range top23 1/2"

(59.7 cm)

25 5/16"(64.3 cm)Rear of control

Panel/oven door

Max. depth to oven door handle with door closed

30"(76.2 cm)

45 1/4"(114.9 cm)

PrODUCT DImENSIONS - TOP vIEw

All tolerances: +1/16”, -0, (+1.6mm, -0) unless otherwise stated

The optional full size side panels are for installation where the side of the range will not be covered by the cabinet. For the right side panel, order Dacor part number ARSR30S. Order part number ARSL30S for the left side.

The above specifications are for reference only. See the product data label for exact specifications.

For self-rimming cutout dimensions, see the following page.

Document # PG05-005 Revised 11/24/10 Page 1/2

Dedicated Circuit Required Total Connected Load240 Vac, 60 Hz., 4-wire*, 50 Amp. 12.5 kW (48.2 Amp.)

ELECTrICAL rEqUIrEmENTS

NOTES:1. Electrical is located in the right rear corner of the unit.2. Range is supplied with a 60” (1524 cm) long 240V 4-wire conduit.

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

2

36" (91.4 cm) recommended30" (76.2 cm) min.

30 1/16"(76.4 cm)

25"(63.5 cm)

Hood

30" (76.2 cm)min.* 10" (25.4 cm)

min. to combustiblesside wall (both sides)

Vertical to combustible surface from cooktop surface

Non-combustible rear wall recommended

Electrical locations** 1) Recommeded 2) Alternate

Consult local code for exact location requirements***

1

Top of finishedcounter

18" (45.7 cm)min.*

13" (33.0 cm)max.

14”H (35.6 cm) X 10”W (25.4 cm)

FrEESTANDING CUTOUT DImENSIONS

Page 58: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.13

mrES30

1/4" (6 mm)min. flat ledge

28 11/16" (72.9 cm) 11/16"(1.7 cm)29 5/8" (75.2 cm)

Rear wall

25"(63.5 cm)

Adjust for backsplashthickness13/16" to 4 1/4" (2.1 - 10.8 cm)

Backsplash

Verticalnon-combustiblesurface rear wall

27 13/16"(70.6 cm)

29 1/4" (74.3 cm)13/32" (1.0 cm)30 1/16" (76.4 cm)

Countertop overhangs cabinet10" (25.4 cm) min.to combustible sidewalls above the range(both sides)

27 7/8" (70.8 cm)

Adjust for backsplashover 3/4" thickfrom 13/16" to 3 13/16" (2.1 - 9.7 cm)

Backsplashthicker than3/4" (1.9 cm)

1/4" (6 mm)min. flat ledge

Vertical non-combustible surface rear wall

2 13/16"(7.1 cm)

TOP vIEw - SLIDE-IN, SELF-rImmING INSTALLATION USING 3” SIDE PANELS wITH BACkGUArD rEmOvED

TOP vIEw - DOwNDrAFT Erv30 wITH SLIDE-IN, SELF-rImmING INSTALLATION USING 3” SIDE PANELSwITH BACkGUArD rEmOvED

All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated

Document # PG05-005 Revised 11/24/10 Page 2/2

30 Inch wide millennia® Electric range

Page 59: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.14

Ranges equipped for installation in Canada:

■ Ranges equipped for use in Canada come pre-wired with a 4-wire, 66 inch (168 cm) long, appliance cord and NEMA 14-50P plug.

■ Do not modify the factory wiring. The plug is designed to plug directly into a NEMA 14-50R electrical receptacle installed by a licensed electrician.

All other models:The conduit or appliance cord installed needs to be long enough to allow the range to be pulled out from the wall for service, while remaining connected. See next page for further details.The wiring to the range must:

◊ Include a strain relief.

◊ Be terminated by tinned leads, closed loop terminals or open ended spade lugs with upturned ends.

Where local code permits, a 3 or 4 wire appliance cord may be used. It must:

◊ Be UL listed type SRD or SRDT.

◊ Be equipped with a NEMA 14-50P 4-wire plug or, where local code permits, a NEMA 10-50P 3-wire plug.

Distinctive range

Dr30D

Optional Backguard and Island Trim Part Numbers

Description Part Number

Island trim kit (no backguard) ADTK30

6 inch trim kit ADB3006

9 inch trim kit ADB3009

Electrical Specifications

Circuit Required Total Connected Load

240 Vac, 60 Hz., 30 Amp.* 5.7 kW (23.8 Amp.)

The ratings above are for reference only - refer to the range's product data label for exact specifications.

NOTE: This range is NOT designed for self-rimming installation or installation with a raised vent.

1 1/8” (2.9 cm)

Rear of front panel/oven door

Front of knobs

Front of open door

Front panel

3” (7.6 cm)Backguard*

6” (15.2 cm)Backguard**

** Optional Standard*

37 7/8”(96.2 cm)

to

35 3/4”(90.8 cm)

Width at front panel: 29 7/8” (75.9 cm)

Finished side panel

9” (22.9 cm)Backguard**

1 1/8” (2.9 mm) to cookingsurface (top of grates) fromtop of trim

26 1/2” (67.3 cm)28 1/2” (72.4 cm)

24 3/8” (61.9 cm)

46 3/8” (117.8 cm)

All tolerances: ±1/16” (±1.6 mm) unless otherwise stated.

WARNING• Observe all governing codes and ordinances during

planning and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

Document # PG05 - 006 Revised 1/26/10 Page 1/2

* Two 120 Vac hot (L1 and L2), one neutral, one ground

The regulator inlet accommodates a 3/4” gas line. The range ships with a 1/2” to 3/4” adapter connected to the regulator.

Gas - Electrical Access Dimensions

A B C D

4 3/4”(12.1 cm)

22 1/8”(56.2 cm)

8 3/4”(22.2 cm)

13 3/4”(34.9 cm)

B

Gas inlet

AC

7/8” (2.2 cm) dia. electrical connection hole in bottom*

D

Range electrical access, cover removed

GAS AND ELECTrICAL DImENSIONS

PrODUCT DImENSIONS

Gas Supply Pressure Requirements*

Gas Type Manifold Pressure Minimum Gas Supply Pressure

Natural gas 5” water column 6” water column

LP 10” water column 11” water column

* Maximum input gas supply pressure for all models is 1/2 p.s.i.

7/8" to 1 1/8" dia. access hole

Page 60: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.15

Distinctive range

Dr30D

Note 2

E

F

2 Cabinet/countertop depth is at discretion of customer but cabinet face MUST NOT protrude further than rear of front panel, see product dimensions.3 Consult local code for exact location requirements.

1 Vertical to combustible surface from range grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances.

Non-combustible surface along

back wallrecommended

10” (25.4 cm) Min.to combustible sidewalls above the range(both sides)

30” (76.2 cm)Min.1

37 7/8(96.2 cm)

Max.

13” (33.0 cm)Max.4

18” (45.7 cm)Min.1, 4

Suggested location of utilities

3

4 Not applicable for cabinets more than a horizontal distance of 10” (25.4 cm) from the edge of the range.

Cutout DimensionsE F

36” (91.4 cm)*30” (76.2 cm)** 30 1/16” (916mm)

* Recommended ** Minimum

Gas and Electrical Service ■ The shaded area shown below denotes the location of the gas inlet

and the electrical junction box/receptacle. This is the recommended location. For replacement purposes, the location of the existing utilities may be utilized provided they do not interfere with the sides or rear of the range. Check local building codes for permissible gas valve locations.

■ An external manual shut-off valve must be installed between the gas inlet and the range for the purpose of turning on or shutting off gas to the appliance.

The installation must allow for the following: ■ Access to the gas shut-off valve when the unit is installed.

■ Access to the remote circuit breaker panel/fuse box when the range is in place.

■ The gas supply piping, gas shut-off valve and the electrical junction box or receptacle must be located so they do not interfere with the range when it is installed.

■ The junction box and gas shut off valve must be located so that the range can be pulled out for service while the appliance remains connected.

Cabinet Layout ■ Carefully check the location where the range is to be installed. For

best performance, the range should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets.

■ To reduce the risk of personal injury and to reduce accumulated smoke in the room, Dacor strongly recommends installing a range hood. A range hood should project horizontally a minimum of five (5) inches beyond the face of the cabinets.

■ All maximum and minimum dimensions and clearances shown in the diagram below must be maintained for safe operation.

■ The range may be installed flush to the rear wall. A non-combustible rear wall is not mandatory, but Dacor highly recommends installing a non-combustible material from the countertop level up to the vent hood or installation of a backguard.

■ Any openings in the wall behind the appliance or in the floor underneath it must be sealed.

rEqUIrED CABINET DImENSIONS

Cabinet tolerances: -1/16”, (+1.6mm) -0

Document # PG05 - 006 Revised 1/26/10 Page 2/2

Page 61: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 6.1

Duct Planning Guide

DUCT PLANNING GUIDEDocument # PG06 - 001 Revised 10/21/09 Page 1/1

WARNING• All blowers, hoods and raised vents must be installed in

accordance with the accompanying installation instructions.• Observe all governing codes and ordinances during planning

and installation. Use only duct work deemed acceptable by state, municipal and local codes and by the installation instructions. Contact your local building department for further information.

• To prevent combustion by-products, smoke or odors from entering the home and to improve efficiency, tape all duct joints securely.

• Hoods and vents may interrupt the proper flow of smoke and combustion gases from furnaces, gas water heaters and fireplaces. To avoid drawing lethal gases into the home, follow the manufacturer’s recommendation for these devices and consult NFPA and ASHRAE recommendations.

• Improper installation may result in a back draft and/or the insufficient venting of smoke and fumes.

• For hoods or raised vents equipped with integral blowers, DO NOT install an additional in-line or external blower to increase the length of the duct run. For hoods or raised vents not equipped with integral blowers, DO NOT install more than one in-line or external blower. Even small differences between blower air flow rates can greatly reduce the air draw.

• To reduce the risk of fire and to properly exhaust air, be sure to duct air outside the house or building. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages.

General Design Requirements◊ All duct work materials (including screws and duct tape) must be

purchased separately by the customer. When planning new duct work, always look for the shortest, most direct route to the outside. Some models can accommodate venting (and/or wiring) through the back.

◊ To prevent a back draft, never decrease the duct size over the run. If existing duct work is smaller than 8 inches in diameter, remove it and replace it with 8" round, 10" inch round or 3 1/4" x 10" duct work. Do not use duct work that is smaller in cross-sectional area than these recommended types. Do not use flexible metal duct.

◊ Do not rely on tape alone to seal duct joints. Fasten all connections with sheet metal screws and tape all joints with certified silver tape or duct tape. Use sheet metal screws as required to support the duct weight.

◊ To prevent back-drafts, a damper at the duct outlet may also be required.

◊ Make sure duct work does not interfere with floor joists or wall studs.

◊ On dual exhaust models, the two 8” exhausts may be merged into one 10” duct using a Dacor transition kit. See the installation instructions for details.

◊ With concrete slab construction, "box-in" the duct work to prevent it from collapsing when the wet concrete is poured. Also allow room for electrical conduit.

Calculating the Maximum Duct Run Length◊ The maximum straight duct length is determined by the type of

hood or raised vent installed and type of duct used. See the hood or raised vent specifications for the maximum duct run for the desired configuration.

◊ To determine the actual length the duct work cannot exceed, subtract all of the equivalent lengths of the elbows and transitions listed below from the maximum straight duct run from the hood/raised vent specifications. After determining that your proposed duct work meets the maximum duct length requirement, proceed with the location planning.

Equivalent LengthsPiece Subtract Piece Subtract

8” 90° elbow 7 feet 10” 90° elbow 5 feet

8” 45° elbow 3 feet 10” 45° elbow 2 feet

3¼” X 10” to round

90° transition25 feet

3¼” X 10” to 8”/10” round

transition4 feet

3 ¼” X 10" 45° elbow 7 feet 3 ¼” X 10"

90° elbow 15 feet

3 ¼” X 10" 90°flatelbow 20 feet

Roof cap * Wall cap with damper *

* The equivalent lengths of roof and wall caps vary with model and configuration. For equivalent length, contact the manufacturer or a qualified HVAC specialist.

Duct Work Design Tips◊ Wherever possible, reduce the number of transitions and turns to as

few sharp angles as possible. Two staggered 45° angles are better than one 90°.

◊ If multiple elbows are used, try to keep a minimum of 24” straight duct between them. Avoid “S” or “back to back” use of adjacent elbows.

◊ Keep turns as far away from the hood or raised vent exhaust as possible, and as much space between bends as possible.

◊ For best performance, use round duct instead of rectangular, especially when elbows are required.

◊ Cross-drafts or air currents caused by adjacent open windows or doors, HVAC outlets, ceiling fans and recessed ceiling lights reduce vent efficiency.

Page 62: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 7.1

DHw Hoods

DHw SErIES OvErALL DImENSIONS

Chimney

24”

Min

. 30”

- M

ax. 4

2”

30” - 36” - 42” - 48”

15”11 3/4”

5 3/4”

12 1

/2”

16 1

/4” *

24 3

/4”

Blower 600 CFM* (1200 CFM* for units with 2 blowers) with electronic speed control

Blower speeds 4

Lights 12 Vac, 20 Watt halogen

Filters Baffletype,dishwashersafe

Exhaust 8 inch

Finish 430 stainless steel

Total connected load

120 Vac, 60 Hz. (see table at right for current rating)

Circuit requirements

120 Vac, 15 Amp. grounded, dedicated 3-wire circuit (hot, neutral, ground)

* At zero inches static pressure

MODEL NUMBERDHW301 DHW361 DHW421 DHW482

Blowers 1 1 1 2

Lights 2 2 3 4

Filters 1 1 1 2

Maximum current draw 3.4 Amp. 3.4 Amp. 3.6 Amp. 6.8 Amp.

IMPORTANT: The minimum installed distance from the hood to the cooking surface must be no less than 30 inches. The minimum specified distance may be higher for the particular range or cooktop in use. Check the manufacturers specifications for the cooktop or range.

* 18” 1/4 on 48 inch model (DHW482)

GENErAL SPECIFICATIONS

mODEL SPECIFIC SPECIFICATIONS

All tolerances: ±1/16” (±1.6 mm), -0, unless otherwise stated

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

• DO NOT install an additional in-line or external blower to increase the length of the duct run. Even small differences between blower air flow rates can greatly reduce the air draw of the hood.

Document # PG07-001 Revised 06/24/10 Page 1/1

30”, 36”, 42” and 48” wide wall mount Chimney Hoods

Maximum Duct LengthThe maximum straight duct length for the hood is 50 feet. To determine the actual maximum duct run, subtract the equivalent length of each elbow, transition and cap from 50 feet. See the Duct Planning Guide or the installation instructions for more details.

rEAr ExHAUST DIAGrAm

■ Chimney can accommodate up to 10” round duct work

■ Unit can be installed to exhaust through the ceiling or through the rear wall (see diagram below).

Page 63: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 7.2

36” (91.4 cm) - 42” (106.7 cm)48” (121.9 cm) - 54” 137.2 cm)

30”(76.2 cm)

15 ¾” (40.0 cm)

Chimney

12 9/16” (31.9 cm)

12

½”

(31.

8 cm

)

15

½”

(39.

4 cm

)*

28”

(71.

1 cm

) to

36” (

91.4

cm

)

DHI SErIES OvErALL DImENSIONS

Blower 600 CFM* (1200 CFM* for units with 2 blowers) with electronic speed control

Blower Speeds 4

Lights 12 Vac, 20 Watt halogen

Filters Baffletype,dishwashersafe

Exhaust 8 Inch

Finish 430 stainless steel

Total connected load 120 Vac, 60 Hz (see table at right for current rating)

Circuit requirements

120 Vac, 15 Amp. grounded, dedicated 3-wire circuit (hot, neutral, ground)

* At zero inches static pressure

** IMPORTANT ORDERING INFORMATION: Each model requires that you order a chimney assembly (Part number DHICH) in addition to the hood assembly part number.

36”, 42”, 48” and 54” wide Ceiling mount Island Hoods

DHI Hoods

Model** Blowers Lights Filters Maximum Current Draw

DHI361 1 4 1 3.8 Amp.

DHI421 1 4 1 3.8 Amp.

DHI482 2 4 2 6.8 Amp.

DHI542 2 6 2 7.1 Amp.

GENErAL SPECIFICATIONS

mODEL SPECIFIC SPECIFICATIONS

* 18” 1/4 on models DHI482 and DHI542

Chimney can accommodate up to 10” round duct work

All tolerances: ±1/16” (±1.6 mm), -0, unless otherwise stated

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

• DO NOT install an additional in-line or external blower to increase the length of the duct run. Even small differences between blower air flow rates can greatly reduce the air draw of the hood.

Document # PG07-002 Revised 06/16/10 Page 1/1

Maximum Duct LengthThe maximum straight duct length for the hood is 50 feet. To determine the actual maximum duct run, subtract the equivalent length of each elbow, transition and cap from 50 feet. See the Duct Planning Guide or the installation instructions for more details.

IMPORTANT: The minimum installed distance from the hood to the cooking surface must be no less than 30 inches. The minimum specified distance may be higher for the particular range or cooktop in use. Check the manufacturers specifications for the cooktop or range.

Page 64: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 7.3

5/16”(3 mm)

30” min.(76.2 cm)

Rear of blowerunit

Cooktopsurface

Glass

30 Inch and 36 Inch wide Glass wall mount range Hoods

PHw

5 3/4”(14.6 cm)

8” dia.203.2 cm)

10 3/4” (27.3 cm) 11 7/8” (30.2 cm)

26 1/8” (66.4 cm)min.*

44” (111.8 cm)max.*

25 3/8” * (64.5 cm)

19 3/4”(50.2 cm)

19 3/4” * (50.2 cm)

30” (76.2 cm) or36” (91.4 cm)**

* Glass thickness of 5/16” (3 mm) not included** Glass width must be specified at time of order. Specify glass part number: PHGXXBK where XX is the width.

OvErALL DImENSIONS

Blower 600 CFM with electronic speed control

Blower Speeds 4

Lights 120 Vac, 50 Watt halogen (1)

Filters Mesh type, dishwasher safe (2)

Exhaust 8 inch

Finish 430 stainless steel with tempered glass hood

Power Required 120 Vac, 60 Hz., 3.5 Amp.

Circuit Required 120 Vac, 60 Hz., 15 Amp. 3-wire (hot, neutral, ground), grounded, dedicated circuit Min.

GENErAL SPECIFICATIONS

Product tolerances: ±1/16” (±1.6 mm), -0, unless otherwise stated

8” (20 cm)CHImNEY mOUNTING

BrACkET

INSTALLATION - SIDE vIEw

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

• The minimum installed distance from the rear of blower unit base to the cooktop surface must be no less than 30” inches (76.2 cm), 26 inches (66.0 cm) for an electric cooktop. The minimum specified distance may be higher for the particular range or cooktop in use. Check the manufacturers specifications for the cooktop or range.

• DO NOT install an additional in-line or external blower to increase the length of the duct run. Even small differences between blower air flow rates can greatly reduce the air draw of the hood.

Document # PG07-003 Revised 01/25/11 Page 1/1

The hood may exhaust through the ceiling on through a rear wall.

ExAmPLE OF rEAr ExHAUST

Maximum Duct LengthThe maximum straight duct length for the hood is 50 feet. To determine the actual maximum duct run, subtract the equivalent length of each elbow, transition and cap from 50 feet. See the Duct Planning Guide or the installation instructions for more details.

Page 65: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 7.4

30”, 36”, 42”, 48”, 54” wide Hoods

EH, EHr and mH wall mount range Hoods

Overall DimensionsModel A B C

EH/EHR3012 29 7/8” (75.9 cm)

26 7/8” (68.3 cm)

12 3/8” (31.4 cm)

EH/EHR3612 35 7/8” (91.1 cm)

EH/EHR4212 41 7/8” (106.4 cm)

EH/EHR4812 47 7/8” (121.6 cm)

MH3012 29 7/8” (75.9 cm)25 1/2”

(64.8 cm)MH3612 35 7/8” (91.1 cm)

MH4812 47 7/8” (121.6 cm)

EH/EHR3018 29 7/8” (75.9 cm)

26 7/8” (68.3 cm)

18” (45.7 cm)

EH/EHR3618 35 7/8” (91.1 cm)

EH/EHR4218 41 7/8” (106.4 cm)

EH/EHR4818 47 7/8” (121.6 cm)

EH/EHR5418 53 7/8 (136.8 cm)

MH3018 29 7/8” (75.9 cm)25” 1/2

(64.8 cm)MH3618 35 7/8” (91.1 cm)

MH4818 47 7/8” (121.6 cm)

11 7/8” (30.2 cm)

A

B

C

OvErALL DImENSIONS

NOTE: The exhaust duct(s) and electrical wiring can be connected from either the top or the back of the hood.

DImENSIONS OF OPTIONAL AHT10 TrANSITION

32” (81.3 cm)

13 ¾” (34.9 cm)

¾” (1.9 cm)

9” (22.9 cm)

2” (5.1 cm)

Minimum Cabinet Width

Models D

EH3012, EH3018, MH3012, MH3018 30” (76.2 cm)

EH3612, EH3618, MH3612, MH3618 36” (91.5 cm)

EH4212, EH4218 42” (106.7 cm)

EH4812, EH4818, MH4812, MH4818 48” (121.9 cm)

EH5418 54” (137.2 cm)

E

25” Min.* (63.5 cm)

Electrical access

All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

Document # PG07-004 Revised 05/14/10 Page 1/3

* Height above cooking surface. The minimum specified distance may be higher for the particular range or cooktop in use. Check the manufacturers specifications for the cooktop or range.

D

Page 66: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 7.5

Weight SpecificationsModels Weight

EH3012, MH3012 48 lbs. (22 kg)

EH3018, MH3018, EH3612, MH3612 53 lbs. (24 kg)

EH3618, MH3618 57 lbs. (26 kg)

EH4212 55 lbs. (25 kg)

EH4218 60 lbs. (27 kg)

EH4812, MH4812 70 lbs. (32 kg)

EH4818, MH4818 77 lbs. (35 kg)

EH5418 84 lbs. (38 kg)

All Models

Fan speeds 4

Filters Mesh type, dishwasher safe

Exhaust(s) 8-inch

Total connect load 120 Vac, 60 Hz, 9 Amp. Max. (10.0 Amp. Max. surge)

Lights 120 Vac, 75 W halogen

Circuit requirement 120 Vac, 15 Amp. dedicated, grounded circuit

Model Specific

EH48, EHR48, MH48, EH54 EH42, EHR42

EH30, EHR30, MH30, EH36, EHR36, MH36

Lights 3 2 2

Filters 4 3 2

Exhaust outputs 2 1 1

Fan* rating 1200 CFM 600 CFM 600 CFM

* Does not apply to EHR Series

GENErAL SPECIFICATIONS

Weight Specifications

Models WeightEHR3012 39 lbs. (18 kg)

EHR3018, EHR3612 44 lbs. (20 kg)

EHR3618 48 lbs. (22 kg)

EHR4212 46 lbs. (21 kg)

EHR4218 51 lbs. (23 kg)

EHR4812 52 lbs. (24 kg)

EHR4818 59 lbs. (27 kg)

EHR5418 66.4 lbs. (30 kg)

Duct Size Maximum Straight Duct Run

8” round 60 feet

10” round 50 feet

3¼” X 10” rectangular 50 feet

IMPORTANT: When planning the installation, you must calculate the actual length the duct work cannot exceed. To calculate actual maximum duct length, use the above specifications in combination with the Duct Planning Guide or see the hood installation instructions.

30”, 36”, 42”, 48”, 54” wide Hoods

EH, EHr and mH wall mount range Hoods

Document # PG07-004 Revised 05/14/10 Page 2/3

Page 67: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 7.6

NOTE: The exhaust duct(s) and electrical wiring can be connected from either the top or the back of the hood.

All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated.

Models EH48, EHR48, MH48, EH54, EHR54 All other models

* **

BACk DImENSIONS

3” (7.6 cm)

¾” (1.9 cm)

Electrical access holes 7/8” Dia. (5.1 cm)

CL

Bottom of hood

Dual exhaust models* Standard 8” duct connection

Single exhaust models** Standard 8” duct connection

9 7/8” (25.1 cm)

19 ¾” (50.2 cm)

4” (10.2 cm)

E***

Front of hood

Dual exhaust models* Standard 8” duct connection

CL

Electrical access holes 7/8” Dia. (5.1 cm)

1 ½” (3.8 cm)

6 1/8” (15.6 cm)

CL

CL

Single exhaust models** Standard 8” duct connection

3” (7.6 cm)

4” (10.2 cm)

9 7/8” (25.1 cm)

19 ¾” (50.2 cm)

TOP DImENSIONS

***Rear Exhaust PlacementNominal Hood Height E

12” 4 1/2” (11.4 cm)

18” 6 1/8” (15.6 cm)

30”, 36”, 42”, 48”, 54” wide Hoods

EH, EHr and mH wall mount range Hoods

Document # PG07-004 Revised 05/14/10 Page 3/3

Page 68: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 7.7

IvS1, IvS2, IvSr1, IvSr2

Integrated ventilation System

21 1/4"(54.0 cm)

22 1/2"(57.2 cm)

6” (15.2 cm)

11 1/16"(28.1 cm)

12 1/4"(31.1 cm)

Electricalaccessholes

8" (20,3 cm) round exhaustwith back draft damper

IvS1/IvSr1 OvErALL DImENSIONS

33 1/4"(84.5 cm)34 1/2"

(87.6 cm)

6” (15.2 cm)

11 1/16"(28.1 cm)

12 1/4"(31.1 cm)

8" (20,3 cm) round exhaustswith back draft damper

Electricalaccessholes

IvS2/IvSr2 OvErALL DImENSIONS

21" (53.3 cm)

8" (20.3 cm)

13" (33.0 cm)

10 inch round

2" (5.1 cm)8" Exhaust

CL

CL

IvS1/IvSr1 ExHAUST DImENSIONS - TOP vIEw

8" Exhaust

CL CL CL

CL

6 1/2"(16.5 cm)

6 1/2"(16.5 cm)

IvS2/IvSr2 ExHAUST DImENSIONS - TOP vIEw

ATD10 DImENSIONS - FOr USE wITH IvS2 AND IvSr2 (SOLD SEPArATELY)

Model No. Dedicated CircuitRequired

Maximum Duct Length

Total Connected Load

Blower Configuration Blower Rating Approximate

Shipping WeightIVS1

120 Vac, 60 Hz., 15 Amp. Min.

grounded,dedicated circuit

Maximum 60 equivalent

straight feet

0.2 kW (2 Amp.) Internal 600 CFM Nom. 25 lbs.

IVSR1 0.2 kW (1.5 Amp.)* Remote** SeeREMPspecifications 21 lbs.

IVS2 0.4 kW (3 Amp.) Internal 1200 CFM Nom. 38 lbs.

IVSR2 0.2 kW (1.5 Amp.)* Remote** SeeREMPspecifications 29 lbs.

* Does not include remote blower. ** Remote blower required. Use only Dacor REMP series remote blower *** At zero inches static pressure

All tolerances: ±1/16” (±1.6 mm) unless otherwise stated.

Document # PG07 - 006 Revised 02/24/10 Page 1/1

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

NOTE: The Dacor IHL series integrated hood liner is designed for use with all Dacor IVS series integrated ventilation systems. Together the IVS and IHL series products can be built into a custom hood structure to provide the required ventilation and heat resistant, easy to clean surfaces.

Page 69: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 7.8

Custom Hood Liners

IHL

IHL SErIES HOOD LINEr DImENSIONS

HEIGHT OF IHL SErIES HOOD LINEr AND IvS SErIES INTEGrATED vENTILATION SYSTEm wHEN ASSEmBLED

vENTILATION SYSTEm COmPATIBILITY

Custom hood

Dacor IVS series integrated ventilation system

Hood liner mounting screw, number required varies with

model, see table

Cap nuts/lock washers for mounting IVS (provided with IHL kit)

21"(53.3 cm)

13 7/16"(34.1 cm)

4"(10.2 cm)

A

Mounting holefor IVS

IHL mounting hole,number and locations

vary with model

CL

10"(25.4 cm)

All tolerances: ±1/16” (±1.6 mm) unless otherwise stated.

Document # PG07-005 Revised 11/30/10 Page 1/1

WARNING• Observe all governing codes and ordinances during planning

and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

IHL Model (A) Width Dimension

Number Mounting Holes/Mounting

Screws Required*IHL30 27” (68.6 cm) 4

IHL36 33” (83.8 cm) 4

IHL42 39” (99.1 cm) 6

IHL48 45” (114.3 cm) 6

IHL54 51” (129.5 cm) 6

IHL Model IVS Model

IHL30 IVS1

IHL36 IVS1

IHL42 IVS2

IHL48 IVS2

IHL54 IVS2

The Dacor IHL series integrated hood liner is used to line the inside of custom built range hoods. It is constructed with non-combustible stainless steel and is designed for use with Dacor IVS series integrated ventilation systems. Together the IVS and IHL series products can be built into a custom hood structure to provide the required ventilation and heat resistant, easy to clean surfaces.

Dacor IHL series hood liner

* #8 mounting screws (not included) are required. Length and type must be determined according to application (mounting material).

Page 70: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.1

30”, 36”, 46”, 48” wide,Slim raised vent

Erv30, Erv36, Erv48,Prv30, Prv36, Prv46

30 ¼"(768 mm)

to37 ¼"

(946 mm)

10"(254 mm)

30"(762 mm)

18 5/8”(473 mm)

5/16” (8 mm)thick stiffeneracross back

3 3/4"(95 mm)

1"(25 mm)

28" 3 prong grounded

power cord

Vent shownin raisedposition

Product data label

Motorcover

Front of unit

6"(152 mm)

2 9/16"(65 mm)

9/16"(14 mm)

2 1/2"(64 mm)

1 15/16"(49 mm)

B

A

Adjustableanchor legs

2 1/8"(54 mm)

2 3/16"(56 mm)

3/16"(5 mm)

Top cap withvent down

DImENSIONS SIDE vIEw DImENSIONS FrONT vIEw

All tolerances: ±1/16” (±1.6 mm) unless otherwise stated

WARNING• Observe all governing codes and ordinances

during planning and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

2 1/8" (54 mm)

3/8"(10 mm)

2 1/8" (54 mm)

ERV top cap - side view

PRV top cap - side view

7/16"(11 mm)

Model No. A B Circuit Requirement*

ERV/PRV30 30” (762 mm)

27 3/8” (695 mm)

Three prong electri-cal outlet connected to 120 Vac, 60 Hz, 15 Amp. grounded, dedicated, circuit

ERV/PRV36 36” (914 mm)

33 3/8” 848 mm)

PRV46 46” (1168 mm)

43 3/8” (1102 mm)

ERV48 48” (1219 mm)

43 3/8” (1102 mm)

* Includes power supply requirements for external blower

NOTES:1. The maximum installed height must not exceed the

maximum specified countertop height of cooking appliances.

2. Install these raised vents only with approved Dacor appliances. See the planning guide for the particular appliance for proper applications and cutout information.

3. This appliance must be install in conjunction with a single Dacor approved remote or in-line blower. See following pages for approved blowers.

Document # PG08-001 Revised 03/29/10 Page 1/3

Page 71: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.2

Erv30, Erv36, Erv48,Prv30, Prv36, Prv46

30”, 36”, 46”, 48” wide,Slim raised vent

Duct Work Design Tips ■ Wherever possible, reduce the number of transitions and turns to as

few sharp angles as possible. Two staggered 45° angles are better than one 90°. Keep turns as far away from the hood exhaust as possible, with as much space between each bend as possible.

■ For best performance, use round duct instead of rectangular when possible, especially when elbows are required.

■ If multiple elbows are used, try to keep a minimum of 24” of straight duct between them. Avoid “S” or “back to back” configurations of adjacent elbows.

■ Do not use flexible metal duct.

Calculating the Maximum Duct Run Length ■ Do not use duct work that is smaller in cross-sectional area than the

required duct sizes in the table to the right.

■ For best performance, keep the duct run as short as possible and never exceed the maximums stated at the right.

■ The maximum straight duct length for the raised vent system depends on the model of remote or in-line blower used with the vent system and the number of elbows and transitions used. The Equivalent Number of Feet for each elbow and transition (see table) must be subtracted from the maximum straight length to compensate for wind resistance. To determine the maximum allowable length of the duct work, subtract all of the equivalent lengths of the elbows and transitions from the Blower Maximum Duct Straight Length.

For example, for a raised vent system using 3 1/4” X 10” rectangular duct, two (2) 3 1/4” X 10” 90° elbows, a 3 1/4” X 10” rectangular to 10” round transition, and a REMP16 remote blower:

■ From the Blower Maximum Duct Straight Length table, the maximum length without transitions and elbows is 60 feet.

■ The equivalent length of each 90° elbow is 15 feet.

■ The equivalent length of 45° elbow is 2 feet.

■ The equivalent length of the transition is 4 feet.

■ The total equivalent length of the above components is: 15 feet + 15 feet + 4 feet + 2 feet = 36 feet.

■ The maximum amount of straight duct that can be used with a REMP16 and the above components is: 60 feet - 34 feet = 24 feet.

Equivalent Number of Feet - Duct Elbows and Transitions

45° elbow 8 Inch 3 feet 3 ¼” X 10

45° elbow 7 feet

45° elbow10 Inch 2 feet 3 ¼” X 10

90° elbow 15 feet

90° elbow 8 Inch 7 feet 3 ¼” X 10

90°flatelbow 20 feet

90° elbow10 Inch” 5 feet

3 ¼” X 10 to 8” roundtransition

4 feet

90° 3 ¼” X 10 to 8” round

transition25 feet

3 ¼” X 10 to 10” round

transition4 feet

Roof cap * Wall cap *

* The equivalent lengths of roof and wall caps vary with model and configuration. For equivalent length, contact the manufacturer or a qualified HVAC specialist.

Document # PG08-001 Revised 03/29/10 Page 2/3

Raised Vent Model No.

Approved Dacor Blowers*

ERV/PRV30Remote blowers:

REMP3 or REMP16In-line blowers:

ILHSF8 or ILHSF10

ERV/PRV36

PRV46

ERV48

*For detailed information on the remote/in-line blowers, refer to the blower installation instructions.

Duct Size Used

Blower Maximum Duct Straight LengthREMP3 Remote Blower REMP16 Remote Blower ILHSF8 In-line Blower ILHSF10 In-line Blower

8 Inch 50 feet (15.2 meters) 60 feet (18.3 meters) 50 feet (15.2 meters) 60 feet (18.3 meters)

10 Inch 40 feet (12.2 meters) 70 feet (21.3 meters) 40 feet (12.2 meters) 70 feet (21.3 meters)

3 ¼” X 10” 40 feet (12.2 meters) 60 feet (18.3 meters) 40 feet (12.2 meters) 60 feet (18.3 meters)

Page 72: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.3

30”, 36”, 46”, 48” wide,Slim raised vent

Erv30, Erv36, Erv48,Prv30, Prv36, Prv46

ExHAUST OUTLET LOCATION OPTIONS

FrONT vIEwSIDE vIEw

All tolerances: ±1/16” (±1.6 mm) unless otherwise stated

NOTE: See the appliance planning guide page for cutout dimensions

Rear Exhaust Knock Out (3 1/4” X 10”)

3”

Vertical center line of rear exhaust knock out lines up with vertical center line of chassis

On 46” and 48” wide models, the vertical center line of bottom knock- out lines up with vertical center line of chassis

On 30” and 36” wide models, the vertical center line of bottom knock- out is offset 3”

Side Exhaust Knock Outs (1 5/8” X 16”)

Bottom Exhaust Knock Out (1 5/8” X 16”)

Motorcover

Front of unit

26" (

660

mm

)

6 1/4"(159 mm)

1 1/8"(29 mm)

CL

CL

CLADT2 TrANSITION (INCLUDED)

wIrING/CONDUIT CONNECTIONS FOr rEmOTE/IN-LINE BLOwEr

3 1/4” X 10” to duct work

2” X 16”, connects to side or bottom exhaust

on raised vent

1"(25 mm)

5"(127 mm)

Blower wiring access hole in bottom

Front of unit

Blower wiring access hole in

side

Document # PG08-001 Revised 03/29/10 Page 3/3

Page 73: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.4

36” and 48” wideSlim raised vent for Epicure® range

Erv36-Er, Erv48-Er

Model Number A B

ERV36-ER 36” (914 mm) 33 3/8” (848 mm)

ERV48-ER 48” (1219 mm) 43 3/8” (1102 mm)

30 ¼"(768 mm)

to37 ¼"

(946 mm)

10"(254 mm)

30"(762 mm)

18 5/8”(473 mm)

5/16” (8 mm)thick stiffeneracross back

3 3/4"(95 mm)

1"(25 mm)

28" 3 prong grounded

power cord

Vent shownin raisedposition

Product data label

Motorcover

Front of unit

6"(152 mm)

2 9/16"(65 mm)

2 1/2"(64 mm)

1 15/16"(49 mm)

B

A

Adjustableanchor legs

2 13/16"(71 mm)

1/4"(6 mm)

Top cap withvent down

Product Dimensions

All tolerances: +/- 1/16” (+/- 1.6 mm) unless otherwise stated

Document # PG08-002 Revised 03/29/10 Page 1/3

WARNING• Observe all governing codes and ordinances

during planning and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

Circuit Requirement (all models)* Approved Dacor Blowers (all models)**

Three prong electrical outlet con-nected to 120 Vac, 60 Hz, 15 Amp.

grounded, dedicated, circuit

Remote blowers: REMP3 or REMP16

In-line blowers: ILHSF8 or ILHSF10

* Includes power supply requirements for external blower.**For detailed information on the remote/in-line blowers, refer to the blower installation instructions.

NOTES:1. Install these raised vents only with approved Dacor

appliances. See the planning guide for the particular appliance for proper applications and cutout information.

2. This appliance must be install in conjunction with a single Dacor approved remote or in-line blower. See following pages for approved blowers.

NOTE: See the appliance planning guide page for cutout dimensions

Page 74: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.5

Erv36-Er, Erv48-ErDocument # PG08-002 Revised 03/29/10 Page 2/3

Duct Work Design Tips ■ Wherever possible, reduce the number of transitions and turns to as

few sharp angles as possible. Two staggered 45° angles are better than one 90°. Keep turns as far away from the hood exhaust as possible, with as much space between each bend as possible.

■ For best performance, use round duct instead of rectangular when possible, especially when elbows are required.

■ If multiple elbows are used, try to keep a minimum of 24” of straight duct between them. Avoid “S” or “back to back” configurations of adjacent elbows.

■ Do not use flexible metal duct.

Calculating the Maximum Duct Run Length ■ Do not use duct work that is smaller in cross-sectional area than the

required duct sizes in the table to the right.

■ For best performance, keep the duct run as short as possible and never exceed the maximums stated at the right.

■ The maximum straight duct length for the raised vent system depends on the model of remote or in-line blower used with the vent system and the number of elbows and transitions used. The Equivalent Number of Feet for each elbow and transition (see table) must be subtracted from the maximum straight length to compensate for wind resistance. To determine the maximum allowable length of the duct work, subtract all of the equivalent lengths of the elbows and transitions from the Blower Maximum Duct Straight Length.

For example, for a raised vent system using 3 1/4” X 10” rectangular duct, two (2) 3 1/4” X 10” 90° elbows, a 3 1/4” X 10” rectangular to 10” round transition, and a REMP16 remote blower:

■ From the Blower Maximum Duct Straight Length table, the maximum length without transitions and elbows is 60 feet.

■ The equivalent length of each 90° elbow is 15 feet.

■ The equivalent length of 45° elbow is 2 feet.

■ The equivalent length of the transition is 4 feet.

■ The total equivalent length of the above components is: 15 feet + 15 feet + 4 feet + 2 feet = 36 feet.

■ The maximum amount of straight duct that can be used with a REMP16 and the above components is: 60 feet - 34 feet = 24 feet.

Equivalent Number of Feet - Duct Elbows and Transitions

45° elbow 8 Inch 3 feet 3 ¼” X 10

45° elbow 7 feet

45° elbow10 Inch 2 feet 3 ¼” X 10

90° elbow 15 feet

90° elbow 8 Inch 7 feet 3 ¼” X 10

90°flatelbow 20 feet

90° elbow10 Inch” 5 feet

3 ¼” X 10 to 8” roundtransition

4 feet

90° 3 ¼” X 10 to 8” round

transition25 feet

3 ¼” X 10 to 10” round

transition4 feet

Roof cap * Wall cap *

* The equivalent lengths of roof and wall caps vary with model and configuration. For equivalent length, contact the manufacturer or a qualified HVAC specialist.

Duct Size Used

Blower Maximum Duct Straight LengthREMP3 Remote Blower REMP16 Remote Blower ILHSF8 In-line Blower ILHSF10 In-line Blower

8 Inch 50 feet (15.2 meters) 60 feet (18.3 meters) 50 feet (15.2 meters) 60 feet (18.3 meters)

10 Inch 40 feet (12.2 meters) 70 feet (21.3 meters) 40 feet (12.2 meters) 70 feet (21.3 meters)

3 ¼” X 10” 40 feet (12.2 meters) 60 feet (18.3 meters) 40 feet (12.2 meters) 60 feet (18.3 meters)

36” and 48” wideSlim raised vent for Epicure® range

Page 75: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.6

Erv36-Er, Erv48-Er

ExHAUST OUTLET LOCATION OPTIONS

FrONT vIEwSIDE vIEw

All tolerances: ±1/16” (±1.6 mm) unless otherwise stated

ADT2 TrANSITION (INCLUDED)

wIrING/CONDUIT CONNECTIONS FOr rEmOTE/IN-LINE BLOwEr

3 1/4” X 10” to duct work

2” X 16”, connects to side or bottom exhaust

on raised vent

1"(25 mm)

5"(127 mm)

Blower wiring access hole in bottom

Front of unit

Blower wiring access hole in

side

Document # PG08-002 Revised 03/29/10 Page 3/3

Rear Exhaust Knock Out (3 1/4” X 10”)

3”

Vertical center line of rear exhaust knock out lines up with vertical center line of chassis

On 46” and 48” wide models, the vertical center line of bottom knock- out lines up with vertical center line of chassis

On 30” and 36” wide models, the vertical center line of bottom knock- out is offset 3”

Side Exhaust Knock Outs (1 5/8” X 16”)

Bottom Exhaust Knock Out (1 5/8” X 16”)

Motorcover

Front of unit 26" (

660

mm

)

6 1/4"(159 mm)

1 1/8"(29 mm)

CL

CL

CL

36” and 48” wideSlim raised vent for Epicure® range

Page 76: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.7

rv30, rv36, rv46

26 3/4"(679 mm)

1/2” (13 mm)thick stiffeneracross back

4 5/8" (117 mm)9 7/8” (251 mm)with CABP3blower installed

Vent shownin raisedposition

Product data label

2 5/16"(59 mm)

9/16"(14 mm)

3 1/8"(79 mm)

2"(51 mm)

B

A

Adjustableanchor legs

1 13/16"(46 mm)

1 15/16"(49 mm)

3/16"(5 mm)

Top cap with vent down

7" (178 mm)

7 1/2" (191 mm)

Front View

15/16" (24 mm)

28"(711 mm)

to34"

(864 mm)

ModelNumber

A - Top CapWidth

B - ChassisWidth

RV30 30” (762 mm) 27 3/8” (695 mm)

RV36 36” (914 mm) 33 3/8” (848 mm)

RV46 46” (1168 mm) 43 3/8” (1102 mm)

All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated

NOTES:1. Install these raised vents only with approved Dacor

cooktops. See the planning guide for the particular appliance for proper applications and cutout information.

2. This appliance must be install in conjunction with a single Dacor approved cabinet, remote or in-line blower. See following pages for approved blowers. For detailed information on the remote and in-line blowers, refer to the blower’s installation instructions.

Document # PG08-003 Revised 03/29/10 Page 1/7

WARNING• Observe all governing codes and ordinances

during planning and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

30”, 36”, 46” wide,raised vent

Page 77: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.8

rv30, rv36, rv46

Electrical Specifications

WARNINGThe electric service for the raised vent should be installed only by a licensed electrician.

It is the owner’s responsibility to ensure that the electrical connection of this appliance is performed by a qualified electrician. The electrical installation, including minimum supply wire size and grounding, must be in accordance with the National Electric code ANSI/NFPA 70- 2002* (or latest revision) and local codes and ordinances.*A copy of this standard may be obtained from:National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101

Electrical RequirementsPower must be supplied by a separate, grounded, single phase circuit protected by a properly sized circuit breaker or time delay fuse and rated at 120 Vac, 60 Hz, 15 Amps.

■ The above specifications are for reference only. If the power supply requirements shown above do not agree with those listed on the product data label, use the ratings on the label.

■ The suggested location of the junction box supplying power to the unit is to the bottom right of the unit, providing local codes permit.

■ Install 3 conductor wiring/conduit with minimum current carrying capacity of 8 Amps to supply power to the internal cabinet blower or remote blower from the raised vent when turned on.

■ When installing a remote or in-line blower run the wiring/ conduit parallel to the duct work and connect it to the remote blower and raised vent on the ends. There are two 7/8” access holes in the bottom of the raised vent for connecting the wiring to the blower and connecting the vent to the power supply junction box.

General System LayoutThe vent system consists of the raised vent itself and a single Dacor approved remote blower or internal cabinet blower.

Raised Vent Model No. Approved Blowers Duct Sizes

RV30CABP3, ILHSF8, ILHSF10,

REMP3, REMP16

3 1/4” x 10”, 8” round, 10” round

RV36

RV46

WARNING• Failure to install an approved blower and proper duct work

will result in a back draft and/or the insufficient venting of smoke and fumes.

• To reduce the risk of personal injury caused by reaching over a hot appliance, cabinet storage space located directly above the cooktop should be avoided.

• Follow the instructions and diagrams for minimum safe clearances and installation location in these instructions, the appliance installation instructions and the blower installation instructions. Failure to do so may result in a fire or safety hazard.

■ Install the raised vent, blower and cooktop so that they can be removed if service is required.

■ Refer to the cooktop planning guide for the minimum cutout dimensions specific to the particular raised vent model being installed.

■ The raised vent is equipped with adjustable anchor legs to accommodate various cabinet heights.

■ All contact surfaces between the raised vent and any cabinets or walls must be solid and at right angles.

Cabinet blower

Connection tocabinet blower

Electrical accessholes in bottom

Connection toremote/in-line

blower

Connection tojunction box

Document # PG08-003 Revised 03/29/10 Page 2/7

30”, 36”, 46” wide,raised vent

ELECTrICAL LAYOUT

Page 78: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.9

General System Layout (continued) ■ The raised vent exhaust may be configured to vent through the

bottom or through one of the sides. Allow room for the exhaust duct coming out of the unit. See Planning the Duct Work for additional details.

■ The maximum allowable duct run must be taken into consideration when determining the layout. See Planning the Duct Work for further details.

■ Access from the front of the cabinet to the underside of the cooktop, the vent system and the electrical and gas supplies for the cooktop and vent must be provided for inspection and service. Any drawers or shelves placed below the cooktop and in front of the vent must be easy to remove for access to the cooktop, vent and utilities.

■ For installation with gas cooktops, a 90-degree elbow must be connected to the cooktop gas inlet (see diagram below) to avoid interference with the raised vent’s front panel.

rv30, rv36, rv46

ExAmPLE OF LAYOUT wITHrEmOTE BLOwEr, rOOF ExHAUST

ExAmPLE OF LAYOUT wITHCABINET BLOwEr, ExHAUST THrOUGH wALL

ExAmPLE OF GAS LINE rOUTING FOr GAS COOkTOPINSTALLATIONS - SIDE vIEw

90° Elbow

Gas line withregulatorattached

Raised Vent withinternal cabinetblower mounted

to front

Optional InternalCabinet Blower

Wall cap

Backsplash

Cooktop

12” (305 mm) Min.

Wal

l

floor

Duct directly through rearwall to wall cap

Internal cabinet blower

3 1/4” x 10”90˚ elbow

REMP16 SeriesRemote Blower

Wall Board

Backsplash

Duct workbetween raisedvent and remote

blower

Raised ventconfigured for

bottom exhaust

Wiring/conduit that supplies power

to remote blowerFloor

Cooktop

3 1/4” X 10”to 10” round

transition and 45°adjustable elbow

Document # PG08-003 Revised 03/29/10 Page 3/7

30”, 36”, 46” wide,raised vent

Page 79: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.10

rv30, rv36, rv46

ExAmPLE OF LAYOUT wITH IN-LINE BLOwEr, DUCT wOrkUNDEr FLOOr, wALL ExHAUST

ILHSF series in-line blower

3 1/4” X 10” to round transition

Duct work Duct work

Outside wall

Cooktop

Wall cap on outside wall

Raised vent

Raised vent configured for

bottom exhaust

Floor

Wiring/conduit from raised vent to in-line blower

Cabinet back

General System Layout (continued)

Document # PG08-003 Revised 03/29/10 Page 4/7

30”, 36”, 46” wide,raised vent

Page 80: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.11

You must install one of the Dacor blower models listed below for proper operation. For models REMP3 or REMP16, see the REMP3/16 Remote Blower Installation Instructions. For model CABP3, see the instructions later in this manual. Only one blower shall be installed.

BLOWER RATINGS FOR DACOR BLOWERS APPROVED FOR USE WITH RV SERIES RAISED VENTS

Model Number RatingCABP3 (cabinet) 600 CFM*

ILHSF8 (in-line) 600 CFM**

ILHSF10 (in-line) 1100 CFM**

REMP3 (remote) 600 CFM**

REMP16 (remote) 1000 CFM**

* Nominal rating at zero inches static pressure, see the CABP3 Cabinet Blower Data for actual rating.** Nominal rating at zero inches static pressure. See the blower installation instructions for actual blower rating.

■ The raised vent can be configured to exhaust through the bottom or either side:

► On installations using a remote or in-line blower, the cover plate on the appropriate side or on the bottom is removed to expose the exhaust. Configure the raised vent for bottom exhaust and use an elbow to vent through the rear cabinet wall.

► On installations using the CABP3 blower, the blower assembly is mounted to the front of the raised vent with the exhaust pointing in the desire direction. Point the exhaust down and use an elbow to vent through the rear cabinet wall.

■ When planning new duct work, always look for the shortest, most direct route to the outside. Calculate the maximum duct length (see following pages) to determine if the planned duct route will work with the blower selected.

■ On bottom exhaust installations you may cut a hole in the floor to allow the duct work to pass through.

■ All duct work materials (including screws and duct tape) must be purchased separately by the customer.

■ You can increase the duct size over the duct run if desired. To prevent a back draft, never decrease the duct size over the run.

■ Do not rely on duct tape alone to seal duct joints. Fasten all connections with sheet metal screws and tape all joints with certified silver tape or duct tape.

■ Use sheet metal screws as require to support the duct weights.

■ To prevent back-drafts, a damper at the duct outlet may also be required.

■ Make sure duct work does not interfere with floor joists or wall studs.

■ With concrete slab construction, “box-in” the duct work to prevent it from collapsing when the wet concrete is poured. Also allow room for electrical wiring from the remote blower.

■ Cross-drafts or air currents from adjacent open windows or doors, heating/air conditioning outlets, ceiling fans and recessed ceiling lights reduce vent efficiency.

Duct Work Design Tips ■ Wherever possible, reduce the number of transitions and turns to as

few sharp angles as possible. Two staggered 45° angles are better than one 90°. Keep turns as far away from the hood exhaust as possible, with as much space between each bend as possible.

■ For best performance, use round duct instead of rectangular when possible, especially when elbows are required.

■ If multiple elbows are used, try to keep a minimum of 24” of straight duct between them. Avoid “S” or “back to back” configurations of adjacent elbows.

■ Do not use flexible metal duct.

Planning the Duct Work

WARNING• To reduce the risk of fire and to properly exhaust air, be sure to duct air outside the house or building. Do not vent exhaust air into

spaces within walls or ceilings or into attics, crawl spaces or garages.• Tape all duct joints securely to prevent combustion by-products, smoke or odors from entering the home. Doing so will also improve

system efficiency.• For proper operation this unit must be installed with a remote blower or internal cabinet blower. Use only one of the models

specified.• TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK. • DO NOT install more than one blower. Even small differences between blower air flow rates can greatly reduce the air draw by the

raised vent.

rv30, rv36, rv46Document # PG08-003 Revised 03/29/10 Page 5/7

30”, 36”, 46” wide,raised vent

Page 81: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.12

rv30, rv36, rv46

FrONT ExHAUST DImENSIONSCABP3 BLOwEr - BOTTOm ExHAUST

ExHAUST LOCATIONS AND DImENSIONSFOr IN-LINE/rEmOTE BLOwEr CONFIGUrATIONS

(ILHSF Or rEmP SErIES BLOwErS)

FrONT ExHAUST DImENSIONSCABP3 BLOwEr - rIGHT ExHAUST

FrONT ExHAUST DImENSIONSCABP3 BLOwEr - LEFT ExHAUST

ExHAUST LOCATIONS AND SIDE DImENSIONSFOr CABP3 INTErNAL CABINET BLOwEr

Side Exhaust Locations (3 1/4” X 10”)

Vertical center line of bottom exhaust lines up with vertical center line of chassis

Internal cabinet blower mounting location

Bottom Exhaust Location (3 1/4” X 10”)

CL

CL

CL1 7/8" *(48 mm)

1 7/8" * (48 mm)

Front View

Bottom View

14 3/8"(365 mm)

*Back of unit lines up with back of cutout

RV

8 3/8" (213 mm)from back of RVcutout to center lineof CABP3 exhaustin any orientation(bottom, or side exahust)

Bottom exhaustconfigutationwith rear or bottomduct routingDUCT

DU

CT

CL

CABP3

Cooktop

Duct connectioncenter line

B

Raised ventcenter lineCountertop

3 1/4 X 10Duct

connection

11 5/8"(295 mm)

Duct connectioncenter line

C

Raised ventcenter lineCountertop

3 1/4 X 10Duct

connection

11 3/4"(298 mm)

25 5/8"(651 mm)

Duct connectioncenter line

A

Raised ventcenter lineCountertop

3 1/4 X 10 Duct connection

Planning the Duct Work (continued)

Model A B CRV30RV36 2” (51 mm) 6” (152 mm) 12” (205 mm)

RV46 5” (127 mm) 9” (229 mm) 9” (229 mm)

Document # PG08-003 Revised 03/29/10 Page 6/7

30”, 36”, 46” wide,raised vent

Page 82: 84B3F5A2-E9C8-4B43-AD58-D5EB1214C6A5_002

PLANNINGGUIDE

www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.13

Calculating the Maximum Duct Run Length ■ Do not use duct work that is smaller in cross-sectional area than the

required duct sizes in the table to the right.

■ For best performance, keep the duct run as short as possible and never exceed the maximums stated at the right.

■ The maximum straight duct length for the raised vent system depends on the model of remote or in-line blower used with the vent system and the number of elbows and transitions used. The Equivalent Number of Feet for each elbow and transition (see table) must be subtracted from the maximum straight length to compensate for wind resistance. To determine the maximum allowable length of the duct work, subtract all of the equivalent lengths of the elbows and transitions from the Blower Maximum Duct Straight Length.

For example, for a raised vent system using 3 1/4” X 10” rectangular duct, two (2) 3 1/4” X 10” 90° elbows, a 3 1/4” X 10” rectangular to 10” round transition with a REMP16 remote blower:

► From the Maximum Equivalent Straight Length table, the maximum length without transitions and elbows is 60 feet.

► The equivalent length of each 90° elbow is 15 feet. ► The equivalent length of 45° elbow is 2 feet. ► The equivalent length of the transition is 4 feet. ► The total equivalent length of the above components is: 15 feet +

15 feet + 4 feet + 2 feet = 36 feet. ► The maximum amount of straight duct that can be used with a

REMP16 and the above components is: 60 feet - 34 feet = 24 feet.

Equivalent Number of Feet -Duct Elbows and Transitions

45° elbow8 Inch 3 feet 3 ¼” X 10

45° elbow 7 feet

45° elbow10 Inch 2 feet 3 ¼” X 10

90° elbow 15 feet

90° elbow8 Inch 7 feet 3 ¼” X 10

90°flatelbow 20 feet

90° elbow10 Inch 5 feet

3 ¼” X 10to 8” roundtransition

4 feet

90° 3 ¼” X 10to 8” roundtransition

25 feet3 ¼” X 10

to 10” roundtransition

4 feet

Roof cap* **Wall cap with

damper* **

* For installations using the CABP3 internal cabinet blower. ** The equivalent lengths of roof and wall caps vary with model and configuration. For equivalent length, contact the manufacturer or a qualified HVAC specialist.

Blower Maximum Duct Straight Length

Blower Used 8 Inch Duct 10 Inch Duct 3 ¼” X 10”Duct

CABP3 50 feet(15.2 meters)

40 feet(12.2 meters)

40 feet(12.2 meters)

ILHSF8 60 feet(18.3 meters)

50 feet(15.2 meters)

50 feet(15.2 meters)

ILHSF10 70 feet(21.3 meters)

80 feet(24.4 meters)

70 feet(21.3 meters)

REMP3 60 feet(18.3 meters)

50 feet(15.2 meters)

50 feet(15.2 meters)

REMP16 70 feet(21.3 meters)

80 feet(24.4 meters)

70 feet(21.3 meters)

rv30, rv36, rv46Document # PG08-003 Revised 03/29/10 Page 7/7

30”, 36”, 46” wide,raised vent