PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. X.1
Table of Contents
TABLE OF CONTENTS
1/2Revised09/07/11
wALL OvENS 1.1-1.16Distinctive Single (DO) 1.1-1.2Distinctive Double (DO) 1.3-1.4Discovery Single (EO/MOH/MOV) 1.5-1.6Discovery Double (EO/MOH/MOV) 1.7-1.8Renaissance Single (EOR/MOR) 1.9-1.10Renaissance Double (EOR/MOR) 1.11-1.12Renaissance Single (RO/ROV) 1.13-1.14Renaissance Double (RO/ROV) 1.15-1.16
wArmING DrAwErS 2.1-2.3Epicure®, Millennia® , Integrated 2.1-2.3
ELECTrIC COOkTOPS 3.1-3.3Millennia (ETT/MET) 3.1-3.3
GAS COOkTOPS 4.1-4.21Epicure Slide-In (EG) 4.1-4.4Drop-In (SGM) 4.5-4.9Renaissance Drop-In (RGC) 4.10-4.13Distinctive Slide-In (DRT) 4.14-4.17Distinctive Drop-In (DCT) 4.18-4.21
rANGES 5.1-5.1530” Epicure All Gas (ER30G) 5.1-5.336” Epicure All Gas (ER36G) 5.4-5.630” Epicure Dual Fuel (ER30D) 5.7-5.936”, 48” Epicure Dual Fuel (ER36D/ER48D) 5.10-5.1130” Millennia Electric (MRES30) 5.12-5.1330” Distinctive Dual Fuel (DR30D) 5.14-5.15
DUCT PLANNING GUIDE 6.1
HOODS 7.1-7.8Millennia Chimney Style, Wall Mount (DHW) 7.1Millennia Island Style (DHI) 7.2Glass Wall Mount (PHW) 7.3Epicure/Millennia Wall Mount (EH, EHR, MH) 7.4-7.6Integrated Ventilation System (IVS, IVSR) 7.7Custom Hood Liner (IHL) 7.8
rAISED vENTS 8.1-8.13Epicure Slim Chassis (ERV, PRV) 8.1-8.3Epicure for ER 36", 48" Ranges (ERV-ER) 8.4-8.6Standard Chassis (RV) 8.7-8.13
BLOwErS 9.1-9.6Cabinet Style for RV Series Raised Vents (CABP) 9.1In-Line (ILHSF) 9.2-9.3Remote (REMP) 9.4-9.6
DISHwASHErS 10.1-10.624” Front Control Panel DDWF24S 10.1 -10.324” Hidden Control Panel EDWH/IDWH 10.4 -10.6
rEFrIGErATION 11.1-11.14Epicure Built-In Wine-Beverage cooler (EF24) 11.1 Epicure Outdoor Refrigerator (OF24) 11.236” Freestanding Glass 3-Door 11.336” Freestanding (EF/IF 3-Door) 11.4-11.742”, 48” Built-In (EF/IF) 11.8-11.1336” Freestanding with Dispenser (EF36IWF) 11.14
mICrOwAvES 12.1-12.7Standard Type, Stainless Steel (DMW2420S) 12.1Trim Kits for Above (AMTK/AOMTK) 12.1Standard Type, Black Glass (DMT2420BK) 12.2Trim Kits for Above (AMTK/AOMTK) 12.2Convection Type (DCM24) 12.3Trim Kits for Above (ACTK/AOCTK) 12.3Standard Type, Over Range Mount (PMOR3021) 12.4Convection Type, Over Range Mount (PCOR30) 12.524" Microwave-In-A-Drawer (MMD24) 12.630" Microwave-In-A-Drawer (MMD30/MMDV30) 12.7
OUTDOOr GrILLS 13.1-13.5Epicure (OB/OBS) 13.1-13.3Built-In Trim kit for OB/OBS Series Grill (OBGT) 13.4Outdoor Grill Carts, OB/OBS Series Grill (OBC) 13.5
BACkGUArDS 14.1Backguard, Stand-Alone (AEB) 14.1
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. X.2
COmBINATIONINSTALLATIONS CI.1-CI.27
Drop-In Gas Cooktop/Raised Vent/SingleWall Oven CI.1Drop-In Electric Cooktop/Raised Vent/SingleWall Oven CI.2Drop-In Gas Cooktop/Slim Raised Vent/SingleWall Oven CI.3Drop-In Electric Cooktop/Slim Raised Vent/SingleWall Oven CI.4Single Wall Oven/Drop-In Cooktop CI.5Raised Vent/30” Epicure Range CI.6Raised Vent/36-48” Epicure Range CI.7Slim Raised Vent/Millennia Range CI.8Slim Raised Vent/Epicure Slide-In Cooktop CI.9Slim Raised Vent/Distinctive Slide-In Cooktop CI.10Drop-In Gas Cooktop/Raised Vent CI.11-CI.12DCT Drop-In Gas Cooktop/Raised Vent CI.13Drop-In Electric Cooktop/Raised Vent CI.14Drop-In Gas Cooktop/Slim Raised Vent CI.15-CI.16Drop-In Electric Cooktop/Slim Raised Vent CI.17 Warming Drawer/Drop-In Cooktop CI.18Warming Drawer/Slide-In Cooktop CI.19Warming Drawer (stacked)/Slide-In Cooktop CI.20Warming Drawer (side-by-side)/Slide-In Cooktop CI.21Microwave/Warming Drawer/Distinctive or Renaissance Wall Oven CI.22Microwave/Warming Drawer CI.23Microwave/Distinctive or Renaissance Wall Oven/Warming Drawer CI.24Microwave/Discovery Wall Oven/Warming Drawer CI.25Microwave/Warming Drawer/Discovery Wall Oven CI.26Discovery Wall Oven/Microwave In-A-Drawer/ Warming Drawer CI.27
Table of Contents
TABLE OF CONTENTS
2/2Revised09/07/11
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.1
DO
Single, Distinctive wall Oven
(A) Overall Width
(B) Chassis Width
(C) Overall Height
(D)* Chassis Height
(E) Control Panel
Overlay29 3/4”
(75.6 cm)28 3/8”
(72.1 cm)28 7/16” (72.4 cm)
27 1/2” (69.9 cm)
15/16” (2.4 cm)
* To top of chassis notch behind control panel
(F) Utility Cutout Width
(G) Utility Cutout Height
(H) Utility Cutout Depth
(J) Control Panel Depth
(K) Notch Depth
(L) Chassis Depth
(M) Notch Height
5” (12.7 cm)
5 ¼” (13.3 cm)
6” (15.2 cm)
1” (2.5 cm)
1 5/8” (4.1 cm)
24” (61.0 cm)
1” (2.5 cm)
21 1/8”(53.7 cm)
ELECTRICAL SPECIFICATIONSDedicated Circuit
Requirements Total Connected Load
240 Vac 60 Hz., 4-wire,*** 30 Amp. 5.3 kW (23 Amp.)
*** Two 120 Vac hot (L1 and L2), one neutral, one groundThe above specifications are for reference only. See the appliance data plate for exact specifications.
C
J
B
H
G
F
A
Chassis NotchSide View
Control panel front Top of
chassis
Top of chassis
Utilitycutout
¾” Conduit:60” (152 cm)
longK
L
ME
D
Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated
Document # PG01-007 Revised 05/25/10 Page 1/2
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
mODEL DO130
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.2
Single, Distinctive wall Oven
DO
1 1/2”(3.8 cm)
typical counter
1“ (2.5 cm) Min.to combustible floor
3/4” (1.9 cm)support platform
1“ (2.5 cm) Min. to combustibles
Recommendedelectricallocation
4” typical toe kick
36”(91.4 cm) P
R
SINGLE wALL OvEN - INSTALLED UNDEr COUNTEr
Recommendedelectricallocation
Alternateelectricallocation
4” typical toe kick
N
P
R3/4” (1.9 cm)
support platform
31 1/4” (79.4 cm)recommended
1” (2.5 cm) Min.to bottom of cabinet door
1” (2.5 cm) Min.to top of
cabinet door
SINGLE wALL OvEN - CUTOUT DImENSIONS
(N) Minimum Cabinet Width
(P) Minimum Cut Out Width
(R) Minimum Cutout Height
30” (76.2 cm)
28 ½” (72.4 cm)
27 5/8” (70.2 cm)
Minimum Interior Cabinet Depth: 24” (61.0 cm)
Cabinet/countertop tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
Document # PG01-007 Revised 05/25/10 Page 2/2
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.3
DO
Double, Distinctive wall Oven
(A) Overall Width
(B) Chassis Width
(C) Overall Height
(D)* Chassis Height
(E) Control Panel
Overlay29 3/4”
(75.6 cm)28 3/8”
(72.1 cm)49 15/16”(126.8 cm)
49 1/16”(124.6 cm)
15/16” (2.4 cm)
* To top of chassis notch behind control panel
(F) Utility Cutout Width
(G) Utility Cutout Height
(H) Utility Cutout Depth
(J) Control Panel Depth
(K) Notch Depth
(L) Chassis Depth
(M) Notch Height
5” (12.7 cm)
5 ¼” (13.3 cm)
6” (15.2 cm)
1” (2.5 cm)
1 5/8” (4.1 cm)
24” (61.0 cm)
1” (2.5 cm)
21 1/8”(53.7 cm)
ELECTRICAL SPECIFICATIONSDedicated Circuit
Requirements Total Connected Load
240 Vac 60 Hz., 4-wire,** 40 Amp. 7.8 kW (33 Amp.)
** Two 120 Vac hot (L1 and L2), one neutral, one ground.The above specifications are for reference only. See the appliance data plate for exact specifications.
C
J
B
H
G
F
A
K
L
ME
Chassis NotchSide View
Control panel front Top of
chassis
Top ofchassis
Utilitycutout
Conduit:60” (152 cm)
Long
D
Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated
mODEL DO230
Document # PG01-008 Revised 05/25/10 Page 1/2
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.4
Double, Distinctive wall Oven
DO
4” typical toe kick
Recommendedelectricallocation
N
P
R
3/4” (1.9 cm)support platform
1” (2.5 cm) min.to bottom of cabinet door
1” (2.5 cm) Min.to top of
drawer face
9 5/8” (24.4 cm)recommended
DOUBLE wALL OvEN - CUTOUT DImENSIONS
(N) Minimum Cabinet Width
(P) Minimum Cut Out Width
(R) Minimum Cutout Height
30” (76.2 cm)
28 ½” (72.4 cm)
49 1/8” (124.8 cm)
Minimum Interior Cabinet Depth: 24” (61.0 cm)
Cabinet/countertop tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
Document # PG01-008 Revised 05/25/10 Page 2/2
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.5
27 and 30 Inch wide, Single,Discovery wall Ovens
EO, mOH, mOv
G
DE
F
C
66” (167.6 cm)Flexible conduit
A
B
1 1/4”(3.2 cm)
H
Chassis notchside view
Control panelfront
Top ofchassis
L
K
Top ofchassis
Utilitycutout
J
Dedicated CircuitRequired
TotalConnected Load
ApproximateShipping Weight
240 Vac, 4-wire*,60Hz, 30 Amp. 4.6 kW (19.5 Amp.) 240 lbs.
* Two 120 Vac hot (L1 and L2), one neutral, one ground.
PrODUCT DImENSIONS
HANDLE DImENSIONS - SIDE vIEw
EO - Epicure ® ® MOH/MOV - Millennia
1 1/4”(3.2 cm)
1 1/4”(3.2 cm)
3 11/16”(9.4 cm)
3 5/16”(8.4 cm)
Model A B C D E F G H J K LEO127
27”(68.6 cm)
27 15/16” (71.0 cm)
23 3/8”(59.4 cm)
2 5/16”(5.9 cm)
7 3/8”(18.7 cm)
6 3/8”(16.2 cm)
27 3/8”(69.5 cm)
25 3/8”(64.4 cm)
9/16”(1.4 cm)
1”(2.5 cm)
1 7/8”(4.6 cm)
MOH127
MOV127
EO13030”
(76.2 cm)28 3/8”
(72.0 cm)MOH130
MOV130
22 11/16”(57.6 cm)
Product tolerances: ±1/16” (±1.6 mm), unless otherwise stated.
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
Document # PG01-001 Revised 01/25/11 Page 1/2
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.6
27 and 30 Inch wide, Single,Discovery wall Ovens
EO, mOH, mOv
NOTES:1. 24” (61.0 cm) minimum interior cabinet depth. Back of
cabinet may need to be removed.2. 3/4” (1.9 cm) support platform (flush with cutout).
CUTOUT DImENSIONS
C
AB
4“ typical toe kick (shown)
Alternateelectrical location3/4” (1.9 cm)
support platform
Recommendedelectrical location
31 1/4” (79.4 cm)recommended
(may be altered)
1 ¾“ (4.5 cm) min.clear to top ofdoor for heat
exhaust
1“ (2.5 cm) min. clear to
bottomof door
CUTOUT DImENSIONS -UNDEr-COUNTEr INSTALLATION
36” Typical(91.4 cm)
1 1/2”(3.8 cm)
typical counter
4“ typical toe kick (shown)
1“ (2.5 cm) min. to combustibles
AB
3/4” (1.9 cm)support platform
Recommendedelectrical location
1 ¾“ (4.5 cm) min.to combustible floor
Model A B CEO127
27 7/16”(69.7 cm)
25 1/2”(64.8 cm)
27”(68.6 cm)MOH127
MOV127
EO13028 1/2”
(72.4 cm)30”
(76.2 cm)MOH130
MOV130
3. 1/8” (3 mm) minimum clearance from appliance to adjacent cabinet doors/drawers.
4. Two (2) Single Ovens are not approved in a stack configuration.
Alternateelectrical locations
4“ (10.2 cm) min.between cutout
Recommended electrical location
4“ typical toe kick (shown)
1“ (2.5 cm) min. to combustibles
AB
3/4” (1.9 cm)support platform
AB
3/4” (1.9 cm)support platform
36” Typical(91.4 cm)
1 1/2”(3.8 cm)
typical counter
1 ¾“ (4.5 cm) min.to combustible floor
CUTOUT DImENSIONS SIDE-BY-SIDE UNDEr-COUNTEr INSTALLATION
Cutout tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated.
Document # PG01-001 Revised 01/25/11 Page 2/2
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.7
27 and 30 Inch wide, Double,Discovery wall Ovens
EO, mOH, mOv
Dedicated CircuitRequired
TotalConnected Load
ApproximateShipping Weight
240 Vac,4-wire*, 60 Hz, 50 Amp. 9.25 kW (38.9 Amp.) 415 lbs.
* Two 120 Vac hot (L1 and L2), one neutral, one ground.
PrODUCT DImENSIONS
G
DE
F
C
66” (167.6 cm)Flexible conduitA
B
1 1/4”(3.2 cm)
H
Chassis notchside view
Control panel front
Top ofchassis
Top ofchassis
Utilitycutout
L
KJ
22 11/16”(57.6 cm)
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
Product tolerances: ±1/16” (±1.6 mm), unless otherwise stated.
Model A B C D E F G H J K LEO227
27”(68.6 cm)
51 1/16” (129.7 cm)
23 3/8”(59.4 cm)
2 5/16”(5.9 cm)
7 3/8”(18.7 cm)
6 3/8”(16.2 cm)
50 1/2”(128.3 cm)
25 3/8”(64.4 cm)
9/16”(1.4 cm)
1”(2.5 cm)
1 7/8”(4.6 cm)
MOH227
MOV227
EO23030”
(76.2 cm)28 3/8”
(72.0 cm)MOH230
MOV230
Document # PG01-002 Revised 01/25/11 Page 1/2
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.8
27 and 30 Inch wide, Double,Discovery wall Ovens
EO, mOH, mOv
NOTES:1. 24” (61.0 cm) minimum interior cabinet depth. Back of
cabinet may need to be removed.2. 3/4” (1.9 cm) support platform (flush with cutout).3. 1/8” (3 mm) minimum clearance from appliance to
adjacent cabinet doors/drawers.
CUTOUT DImENSIONS
A
B
4“ typical toe kick (shown)
3/4” (1.9 cm)support platform
Recommendedelectrical location
9 5/8” (24.4 cm)recommended
(may be altered)
1 ¾“ (4.5 cm) min.clear to top ofdoor for heat
exhaust
1“ (2.5 cm) min.clear to
bottom ofdoor
C
Model A B CEO227
50 9/16”(128.4 cm)
25 1/2”(64.8 cm)
27”(68.6 cm)MOH227
MOV227
EO23028 1/2”
(72.4 cm)30”
(76.2 cm)MOH230
MOV230
Document # PG01-002 Revised 01/25/11 Page 2/2
HANDLE DImENSIONS - SIDE vIEw
EO - Epicure ® ® MOH/MOV - Millennia
1 1/4”(3.2 cm)
1 1/4”(3.2 cm)
3 11/16”(9.4 cm)
3 5/16”(8.4 cm)
Cutout tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated.
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.9
27”, 30”, 36” wide, Single,renaissance wall Ovens
EOr, mOr
Model Number
(A) Overall Width
(B)* Chassis Width
(C) Overall Height
(D)** Chassis Height
(E) Control Panel
OverlayEORS127/MORS127
26 7/8” (68.3 cm)
25 3/8” (64.5 cm) 28 7/16”
(72.4 cm)27 1/2”
(69.9 cm)15/16”
(23.8 cm)EORS130/MORS130
29 7/8” (75.9 cm)
28 3/8” (72.1 cm)
EORS136 35 7/8” (91.1 cm)
34 3/8” (87.3 cm)
28 1/8” (71.4 cm)
27 1/4” (69.2 cm)
7/8” (2.2 cm)
* Width at light covers on sides ** To top of chassis notch behind control panel
(F) Utility Cutout Width
(G) Utility Cutout Height
(H) Utility Cutout Depth
(J) Control Panel Depth
(K) Notch Depth
(L) Chassis Depth
(M) Notch Height
All models 5” (12.7 cm)
5 ¼” (13.3 cm)
6” (15.2 cm)
1” (2.54 cm)
1 1/8” (2.9 cm)
24” (61.0 cm)
1” (2.5 cm)
21 1/8”
3 3/8”(8.6 cm)
1”(2.5 cm)
1”(2.5 cm)
Epicure Millennia - (Handle is integral)
HANDLE DImENSIONS
Model Number
Dedicated Circuit Requirements
Total Connected Load
EORS127
240 Vac 60 Hz., 4-wire***, 30 Amp.
5.0 kW (20.8 Amp.)MORS127EORS130MORS130EORS136 5.3 kW (22 Amp.)
*** Two 120 Vac hot (L1 and L2), one neutral, one groundThe above specifications are for reference only. See the appliance data plate for exact specifications.
C
J
B*
H
G
F
A
Chassis NotchSide View
Control panel front Top of
chassis
Top of chassis
Utilitycutout
Lightcover
Conduit:60” (152 cm)
LongK
L
ME
D
All tolerances: ±1/16” (±1.6 mm) unless otherwise stated
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
Document # PG01-003 Revised 05/25/10 Page 1/2
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.10
27”, 30”, 36” wide, Single,renaissance wall Ovens
EOr, mOr
1 1/2”(3.8 cm)
typical counter
1“ (2.5 cm) Min.to combustible floor
3/4” (1.9 cm)support platform
1“ (25 mm) Min. to combustibles
Recommendedelectricallocation
4” typical toe kick
36”(91.4 cm) P
R
SINGLE wALL OvEN - INSTALLED UNDEr COUNTEr
Recommendedelectricallocation
Alternateelectricallocation
4” typical toe kick
N
P
R3/4” (1.9 cm)
support platform
31 1/4” (79.4 cm)recommended
1” (2.5 cm) Min.to bottom of cabinet door
1” (2.5 cm) Min.to top of
cabinet door
SINGLE wALL OvEN - CUT OUT DImENSIONS
Model Number (N) Minimum Cabinet Width
(P) Minimum Cut Out Width
(R) Minimum Cut out Height
EORS127/MORS127
27” (68.6 cm)
25 ½” (64.8 cm) 27 5/8”
(70.2 cm)EORS130/MORS130
30” (76.2 cm)
28 ½” (72.4 cm))
EORS136 36” (91.4 cm)
34 ½” (87.6 cm)
27 ½” (69.9 cm)
Minimum Interior Cabinet Depth: 24” (61.0 cm)
All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
Document # PG01-003 Revised 05/25/10 Page 2/2
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.11
27”, 30”, 36” wide, Double,renaissance wall Ovens
EOr, mOr
C
J
B*
H
G
F
A
K
L
ME
Chassis NotchSide View
Control panel front Top of
chassis
Top ofchassis
Utilitycutout
Lightcover
Lightcover
Conduit:60” (152 cm)
Long
D
3 3/8”(8.6 cm)
1”(2.5 cm)
1”(2.5 cm)
Model Number
(A) Overall Width
(B)* Chassis Width
(C) Overall Height
(D)** Chassis Height
(E) Control Panel
Overlay
EORX227/MORX227
26 7/8” (68.3 cm)
25 3/8” (64.5 cm) 49 15/16”
(127.0 cm)49 1/16”
(124.6 cm)7/8”
(2.2 cm)EORX230/MORX230
29 7/8” (75.9 cm)
28 3/8” (72.1 cm)
X = Number of convection ovens: S = single, D = double * Width at light covers on sides ** To top of chassis notch behind control panel
(F) Utility Cutout Width
(G) Utility Cutout Height
(H) Utility Cutout Depth
(J) Control Panel Depth
(K) Notch Depth
(L) Chassis Depth
(M) Notch Height
All models
5” (12.7 cm)
5 ¼” (13.3 cm)
6” (15.2 cm)
1” (2.5 cm)
1 1/8” (2.9 cm)
24” (61.0 cm)
1” (2.5 cm)
Model Number Dedicated Circuit Requirements
Total Connected Load
EORS227/ MORS227 240 Vac 60 Hz, 4-wire***, 40 Amp. 7.8 kW (33 Amp.)
EORS230/ MORS230EORD227/ MORD227 240 Vac 60 Hz,
4-wire***, 50 Amp. 10.0 kW (42 Amp.)EORD230/ MORD230
*** Two 120 Vac hot (L1 and L2), one neutral, one groundThe above specifications are for reference only. See the appliance data plate for exact specifications.
21 1/8”
Epicure Millennia (Handle is integral)
HANDLE DImENSIONS
All tolerances: ±1/16” (±1.6 mm) unless otherwise stated
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
Document # PG01-004 Revised 05/25/10 Page 1/2
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.12
27”, 30”, 36” wide, Double,renaissance wall Ovens
EOr, mOr
4” typical toe kick
Recommendedelectricallocation
N
P
R
3/4” (1.9 cm)support platform
1” (2.5 cm) min.to bottom of cabinet door
1” (2.5 cm) Min.to top of
drawer face
9 5/8” (24.4 cm)recommended
DOUBLE wALL OvEN - CUT OUT DImENSIONS
Model Number
(N) Minimum Cabinet Width
(P) Minimum Cut Out Width
(R) Minimum Cut-out Height
EORX227/MORX227 27” (68.6 cm) 25 ½” (64.8 cm)
49 1/8” (124.8 cm)EORX230/MORX230 30” (76.2 cm) 28 ½” (72.4 cm)
X = Number of convection ovens: S = Single, D = Double
All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
Document # PG01-004 Revised 05/25/10 Page 2/2
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.13
rO130, rOv130
30 Inch, Single, renaissance wall Oven
(A) Overall Width
(B) Chassis Width
(C) Overall Height
(D) Chassis Height
(E) Control Panel
Overlay29 7/8”
(75.9 cm)28 3/8”
(72.1 cm)28 5/8”
(70.2 cm)26 5/8”
(67.6 cm)1”
(2.5 cm)
(F) Utility Cutout Width
(G) Utility Cutout Height
(H) Utility Cutout Depth
(J) Control Panel Depth
(K) Chassis Depth
6 1/4”(15.9 cm)
4 3/4”(12.1 cm)
7 3/4”(19.7 cm)
1 3/16”(3.0 cm)
23 5/8”(60.0 cm)
ELECTRICAL SPECIFICATIONSDedicated Circuit
Requirements Total Connected Load
240 Vac 60 Hz., 4-wire,* 30 Amp. 6.0 kW (25.0 Amp.)
* Two 120 Vac hot (L1 and L2), one neutral, one ground. Fuse/circuit breaker on both L1 and L2.The above specifications are for reference only. See the product data plate for exact specifications.
Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated
Document # PG01-009 Revised 09/07/11 Page 1/2
WARNING• Observe all governing codes and ordinances during
planning and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
C
J
B
H
G
F
A
Control panelside view
Control panel front Top of
chassis
Top of chassis
Utilitycutout
Conduit:60” (152 cm)
long
K
E
D
21 1/8”
3 1/2”(8.9 cm)
3 3/16”(8.1 cm)
1 1/8”(2.9 cm)
1 1/8”(2.9 cm)
HANDLE DImENSIONS
Epicure Millennia (Order kit #AMOH30))
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.14
30 Inch, Single, renaissance wall Oven
rO130, rOv130
SINGLE wALL OvEN - INSTALLED UNDEr COUNTEr
SINGLE wALL OvEN - CUTOUT DImENSIONS
(N) Minimum Cabinet Width
(P) Minimum Cut Out Width
(R) Minimum Cutout Height
30” (76.2 cm)
28 1/2” (72.4 cm)
26 7/8” (68.3 cm)
Minimum interior cabinet depth: 24” (61.0 cm)
Cabinet tolerances: +1/16” (+1.6 mm) -0, unless otherwise stated
Document # PG01-009 Revised 09/07/11 Page 2/2
1 1/2”(3.8 cm)
typical counter
1“ (2.5 cm) min.to combustible floor
3/4” (1.9 cm)support platform
1“ (2.5 cm) min. to combustibles
Recommendedelectricallocation
4” typical toe kick
36” typ.(91.4 cm) P
R
Recommendedelectricallocation
Alternateelectricallocation
4” typical toe kick
P
R3/4” (1.9 cm)
support platform
31 1/4” (79.4 cm)recommended
1” (2.5 cm) min.to bottom of cabinet door
1” (2.5 cm) min.to top of
cabinet door
N
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.15
rO230, rOv230
30 Inch, Double, renaissance wall Oven
(A) Overall Width
(B) Chassis Width
(C) Overall Height
(D) Chassis Height
(E) Control Panel
Overlay29 7/8”
(75.9 cm)28 3/8”
(72.1 cm)49 7/8”
(126.7 cm)49”
(124.5 cm)7/8”
(2.2 cm)
(F) Utility Cutout Width
(G) Utility Cutout Height
(H) Utility Cutout Depth
(J) Control Panel Depth
(K) Chassis Depth
6 1/4”(15.9 cm)
4 3/4”(12.1 cm)
7 3/4”(19.7 cm)
1 3/16”(3.0 cm)
23 5/8”(60.0 cm)
ELECTRICAL SPECIFICATIONSDedicated Circuit
Requirements Total Connected Load
240 Vac 60 Hz., 4-wire,* 60 Amp. 11.6 kW (48.6 Amp.)
* Two 120 Vac hot (L1 and L2), one neutral, one ground. Fuse/circuit breaker on both L1 and L2.The above specifications are for reference only. See the product data plate for exact specifications.
Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated
Document # PG01-010 Revised 08/26/11 Page 1/2
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
21 1/8”
3 1/2”(8.9 cm)
3 3/16”(8.1 cm)
1 1/8”(2.9 cm)
1 1/8”(2.9 cm)
HANDLE DImENSIONS
Epicure Millennia (Order kit #AMOH30))
C
A
Conduit:60” (152 cm)
Long
D
J
B
H
G
F
Top of chassis
Utilitycutout
K
Control panelside view
Control panel front Top of
chassisE
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 1.16
30 Inch, Double, renaissance wall Oven
rO230, rOv230
DOUBLE wALL OvEN - CUTOUT DImENSIONS
(N) Minimum Cabinet Width
(P) Minimum Cut Out Width
(R) Minimum Cutout Height
30” (76.2 cm)
28 1/2” (72.4 cm)
49 1/8” (124.8 cm)
Minimum interior cabinet depth: 24” (61.0 cm)
Cabinet tolerances: +1/16” (+1.6 mm) -0, unless otherwise stated
Document # PG01-010 Revised 08/26/11 Page 2/2
4” typical toe kick
Recommendedelectricallocation
N
P
R
3/4” (1.9 cm)support platform
1” (2.5 cm) min.to bottom of cabinet door
1” (2.5 cm) min.to top of
drawer face
9 5/8” (24.4 cm)recommended
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 2.1
24”, 27”, 30”, 36”, wide warming Drawers
ErwD, EwD, IwD, mrwD, mwDv, mwDH, OwD
Document # PG02-002 Revised 01/24/11 Page 1/3
Drawer open
Chassis
5/64"(2 mm)
23 13/16”(60.5 cm)
23 3/8”(59.4 cm)
BC
OvErALL DImENSIONS - TOP vIEw(EwD SErIES SHOwN)
A
10 1/8”(257 mm)
DrAwEr FACE DImENSIONS(MWD SerieS ShoWn)
3 7/16"(8.7 cm)
EWD
3 1/4"(8.3 cm)
MWDH/V
1"(2.5 cm)
3 1/2"(8.9 cm)
MRWD30B(only)
All other MRWDseries
ERWD
1 1/8"(2.9 cm)
1 7/16"(3.7 cm)
1"(2.5 cm)
1"(2.5 cm)
HANDLE DImENSIONS - SIDE vIEw
CHASSIS DImENSIONS
10"(25.4 cm)
9"(22.9 cm)1/2" (1.3 cm)
1/2" (1.3 cm)
Chassis without drawer inserted
Mounting hole 9 places
40” (101.6 cm) 3-prong 120 Vac
power cord
Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated
wArmING DrAwEr OvErALL DImENSIONS
Model (A) Drawer Face Width
(B) Chassis Face Width
(C) Chassis Width
ERWD27 27” (68.6 cm) 26 5/8” (67.6 cm) 25 1/4” (64.1 cm)
ERWD30 30” (76.2 cm) 29 5/8” (75.2 cm) 28 1/4” (71.8 cm)
EWD24 24” (61.0 cm) 23 5/8” (60.0 cm) 22 1/4” (56.5 cm)
EWD27 27” (68.6 cm) 26 5/8” (67.6 cm) 25 1/4” (64.1 cm)
EWD30 30” (76.2 cm) 29 5/8” (75.2 cm) 28 1/4” (71.8 cm)
EWD36 36” (91.4 cm) 35 5/8” (90.5 cm) 34 1/4” (87.0 cm)
MRWD27 26 3/4” (67.9 cm) 26 5/8” (67.6 cm) 25 1/4” (64.1 cm)
MRWD30 29 3/4” (75.6 cm) 29 5/8” (75.2 cm) 28 1/4” (71.8 cm)
MWDH27 27” (68.6 cm) 26 5/8” (67.6 cm) 25 1/4” (64.1 cm)
MWDH30 30” (76.2 cm) 29 5/8” (75.2 cm) 28 1/4” (71.8 cm)
MWDV27 27” (68.6 cm) 26 5/8” (67.6 cm) 25 1/4” (64.1 cm)
MWDV30 30” (76.2 cm) 29 5/8” (75.2 cm) 28 1/4” (71.8 cm)
Electrical Circuit Required Total Connected Load Minimum Ambient Operating Temperature
120 Vac, 60 Hz, 15 Amp. grounded, dedicated circuit
4.0 Amp. @ 120 Vac, 60 Hz. 32°F (0°C)
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 2.2
24”, 27”, 30”, 36”, wide warming Drawers
ErwD, EwD, IwD, mrwD, mwDv, mwDH, OwD
Document # PG02-002 Revised 01/24/11 Page 2/3
D
A
DrAwEr FACE DImENSIONS(iWD/oWD SerieS ShoWn)
Chassis
Drawer open F
E
5/16”(8 mm)
BC
OvErALL DImENSIONS - IwD/OwD SErIES TOP vIEw
CHASSIS DImENSIONS(iWD/oWD ShoWn)
40" (101.6 cm)3 prong
120 Vac power cord
Chassis withoutdrawer installed
Mounting hole,
** = OWD24 mounting holes
** **
** **
9 places
G
Model (A) Dimension Drawer Face Width
(B) Dimension Chassis Width
(C) Dimension Chassis Face
Width
(D) Dimension
Drawer Face Height
(E) Dimension
Chassis Depth
(F) Dimension
Drawer Depth
(G) Dimension
Chassis Height
IWD24 22 5/16” (56.7 cm) 22 1/4” (56.5 cm) 22 3/8” (56.8 cm)8 15/16” (22.7 cm)
23 3/8” (59.4 cm)
23 13/16” (60.5 cm)
9 1/16” (23.0 cm)IWD27 25 5/16” (64.3 cm) 25 1/4” (64.1 cm) 25 3/8” (64.5 cm)
IWD30 28 5/16” (71.9 cm) 28 1/4” (71.8 cm) 28 3/8” (72.1 cm)
OWD24 22 1/2” (57.1 cm) 22 1/2” (57.1 cm) 22 1/2” (57.1 cm) 11 7/8” (30.2 cm)
20” (50.8 cm)
18” (45.7 cm)
11 7/8” (30.2 cm)
Product tolerances: ±1/16” (±1.6 mm) unless otherwise statedElectrical Circuit Required Total Connected Load Minimum Ambient
Operating Temperature
120 Vac, 60 Hz, 15 Amp. grounded, dedicated circuit
4.0 Amp. @ 120 Vac, 60 Hz. 32°F (0°C)
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 2.3
24”, 27”, 30”, 36” wide warming Drawers
ErwD, EwD, IwD, mrwD, mwDv, mwDH, OwDDocument # PG02-002 Revised 01/24/11 Page 3/3
Warmingdrawer
Cooktop1 1/2" (3.8 cm)Typical countertop
3/4” min.*(1.9 cm)
120 Vac electricaloutlet
A36" typ.
(91.4 cm)B
C
A
Warmingdrawer
Warmingdrawer
B
3/4" min.*(1.9 cm)
D
3/4" min.*(1.9 cm)
36" typ.(91.4 cm) 120 Vac
electricaloutlet
C
C
27"/30"/36" Dacorsingle wall oven
Warmingdrawer
Warmingdrawer
Toe kick
D
C
C
D
120 Vacelect.
120 Vacelect.
A3/4" min.*(1.9 cm)
Cabinet/countertop tolerances: +1/16” (+1.6 mm) -0 unless otherwise stated
* Bare minimum spacing to allow for ventilation and avoid scraping on ERWD, EWD, MRWD, MWDH and MWDV series models.** On IWD series models or OWD24 without the optional front panel kit: The chassis and the drawer faceplate are smaller than the cutout. The custom front panel mounts to the drawer faceplate. The height and width of the custom front panel must exceed the appropriate cutout dimensions (A and C above) to cover the hole. Allow 1/4" minimum additional space on the top, bottom and sides from the custom front panel edge to prevent scraping against adjacent doors, drawers and the countertop.*** OWD24 with optional factory front panel kit only. Bare minimum spacing shown to avoid scraping. Gap above and below cutout is 3/4” minimum. See ** above for OWD24 with custom front panel.**** Model EWD36 cannot be installed above or below another warming drawer (any type).***** Model OWD24 cannot be installed above, below or adjacent to a wall oven or warming drawer (any type).
Model (A) Cutout Width(B) Min. Width to Adjacent Doors/
Drawers(C) Cutout Height (D) Min. Vertical Gap
Between Cutouts Min. Cutout Depth
ERWD27 25 1/2” (64.8 cm) 27 1/4” (69.2 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*ERWD30 28 1/2” (72.4 cm) 30 1/4” (76.8 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*EWD24 22 1/2” (57.2 cm) 24 1/4” (61.6 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*
24” (61.0 cm)
EWD27 25 1/2” (64.8 cm) 27 1/4” (69.2 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*EWD30 28 1/2” (72.4 cm) 30 1/4” (76.8 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*EWD36**** 34 1/2” (87.6 cm) 36 1/4” (92.1 cm)* 9 1/8” (23.2 cm) NAIWD24 22 1/2” (57.2 cm) ** 9 1/8” (23.2 cm) 1 1/16” (2.7 cm)IWD27 25 1/2” (64.8 cm) ** 9 1/8” (23.2 cm) 1 1/16” (2.7 cm)IWD30 28 1/2” (72.4 cm) ** 9 1/8” (23.2 cm) 1 1/16” (2.7 cm)MRWD27 25 1/2” (64.8 cm) 27” (68.6 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*MRWD30 28 1/2” (72.4 cm) 30” (76.2 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*MWDH27 25 1/2” (64.8 cm) 27 1/4” (69.2 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*MWDH30 28 1/2” (72.4 cm) 30 1/4” (76.8 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*MWDV27 25 1/2” (64.8 cm) 27 1/4” (69.2 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*MWDV30 28 1/2” (72.4 cm) 30 1/4” (76.8 cm)* 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)*OWD24***** 22 5/8” (57.5 cm) 24 1/4” (61.6 cm)*** 11 15/16” (30.3 cm) NA 20 1/8” (51.1 cm)
WARNING• Observe all governing codes and ordinances
during planning and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
Mounting platform must be 3/4" (1.9 cm) thick and support 100 lbs.
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 3.1
30 Inch and 36 Inch wide,millennia® Electric Cooktops
PrODUCT DImENSIONS - ETT365-2 AND mETB365-1 (ETT365-2 SHOwN)
36 1/4" *(921 mm)
34 3/8"(873 mm)
19 3/8" (495 mm)21 1/4" *
(540 mm)
4" (102 mm)Chassis height
30 1/4" *(768 mm)
28 3/8"(721 mm)19 3/8"
(495 mm)21 1/4" *(540 mm)
4" (102 mm)Chassis height
PrODUCT DImENSIONS - ETT304-1 AND mET304 (ETT304-1 SHOwN)
ETT304-1, ETT365-2, mET304 and mETB365-1
Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted
Document # PG03-001 Revised 05/06/10 Page 1/3
NOTES:1. The cooktop is supplied with a flexible, 48 inch long
power conduit consisting of two (2) insulated hot lead conductors (L1 and L2) and one (1) insulated ground conductor. There is no neutral connection. All leads are copper. The conduit is connected to the right corner of the cooktop. Do not connect the ground wire to neutral.
2. Tested in accordance with the latest edition of ANSI Z21.1 and U.L. 858 Standard for household cooking appliances.
3. These cooktops are not approved for recessed installation.
Model No. Electrical Circuit Required Total Connected Load*
Minimum Supply Wire Size Line and Ground Connections
ETT304-1 240 Vac, 60 Hz, 40 Amps. 6.9 kW (29 Amps.)
No. 8 AWGETT365-2 240 Vac, 60 Hz, 40 Amps. 9.1 kW (38 Amps.)
MET304 240 Vac, 60 Hz, 40 Amps. 6.9 kW (29 Amps.)
METB365-1 240 Vac, 60 Hz, 50 Amps.* 9.6 kW (40 Amps.)
* For reference only, See the product data label on bottom of unit for exact specifications.
ELECTrICAL SUPPLY rEqUIrEmENTS
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
* For units with stainless steel trim, other units may be up to 1/8" less.
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 3.2
30 Inch and 36 Inch wide,millennia® Electric Cooktops
ETT304-1, ETT365-2, mET304 and mETB365-1
All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
Document # PG03-001 Revised 05/06/10 Page 2/3
When installing model ETT365-2 or METB365-1 and the bottom of the chassis is to be enclosed wall to wall, you must install Dacor ventilation duct kit ATD323.
Allow a minimum of 6 inches (152 mm) clearance between the top of the countertop and any combustible surface below, including the upper edge of a drawer below the cooktop. Proper under-cabinet clearance is also required for the cooktop hold down brackets.
6” (152 mm)Min. clearanceto combustiblesurfacesA
6" (152 mm) Min. from mounting surface to combustibles belowcooktop chassis
B
Min. to combustible,side wall, both sides
Rearwall
1" Min.
19 3/4" Min.(502 mm)
6" (152 mm)(25 mm)
2 1/4" Min.(57 mm)
UNDEr COUNTEr CLEArANCE
Model (A) Minimum Under Counter Clearance (Width)
ETT304-1, MET304 30 1/2” (775 mm)
ETT365-2, METB365-1 36 1/2” (927 mm)
Model (B) Minimum Under Counter Clearance (Width)
ETT304-1, MET304 28 3/4” (730 mm)
ETT365-2, METB365-1 34 3/4” (883 mm)
COUNTErTOP CUTOUT (wITHOUT rAISED vENT)
3/4”
7 3/4” X 4 3/8”ventilationcut-outsinenclosurefloor
1 1/2” 1 1/2”3/4”
TOP vIEw vENTILATION CUTOUT
Cooktop cutout in top of cabinet
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 3.3
30 Inch and 36 Inch wide,millennia® Electric Cooktops
Stiffener
Cabinet face
Countertop
Floor
3/8” Min. (10 mm) space behind raised vent chassis to clear stiffener
3/8” Min. (10 mm)flat countertop overhangrequired behind cutout
ERV or PRV series raised vent: Check raised vent dimensions/specifications to determine proper fit
ETT or MET series cooktop
19 3/4"(502 mm)
6" Min.(152 mm)
6" Min.(152 mm)
1" Min.(25 mm)
Cabinetface
A
B
C
D E
6" (152 mm) Min. from mounting surface to combustibles belowcooktop chassis
Rearwall
Stiffener
Cabinet face
Countertop
Floor
5/8” Min. (16 mm) space behind raised vent chassis to clear stiffener
5/8” Min. (16 mm)flat countertop overhangrequired behind cutout
RV series raised vent: Check raised vent dimensions/specifications to determine proper fit
ETT or MET series cooktop
Erv AND Prv SErIES rAISED vENT INSTALLATION SIDE vIEw
rv SErIES rAISED vENT INSTALLATION SIDE vIEw
COUNTErTOP CUTOUT (wITH rAISED vENT) TOP vIEw
COUNTErTOP CUTOUT (wITH rAISED vENT) ISO vIEw
ETT304-1, ETT365-2, mET304 and mETB365-1
All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
Document # PG03-001 Revised 05/06/10 Page 3/3
Model/Configuration (A) Cooktop Cutout Width
(B) Raised Vent Cutout Width
(C) Total Cutout Depth
(D) Raised Vent Cutout Depth
(E) Minimum Rear Countertop
OverhangETT304-1 or MET304 cooktop with ERV30 or PRV30 raised vent 28 3/4”
(730 mm)27 3/4”
(705 mm)
22 1/2”(572 mm)
2 3/4”(70 mm)
3/8”(10 mm)
ETT304-1 or MET304 cooktop withRV30 raised vent
22 1/4”(565 mm)
2 1/2”(64 mm)
5/8”(16 mm)
ETT365-2 or METB365-1 cooktop with ERV36 or PRV36 raised vent 34 3/4”
(883 mm)33 3/4”
(857 mm)
22 1/2”(572 mm))
2 3/4”(70 mm)
3/8”(10 mm)
ETT365-2 or METB365-1 cooktop with RV36 raised vent
22 1/4”(565 mm)
2 1/2”(64 mm)
5/8”(16 mm)
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.1
A
EG366, EG486
ELECTrIC CIrCUIT rEqUIrEmENTS
Circuit Required Total Connected Load
120 Vac 60Hz, 15 Amp. (3 wire) 0.25 Amp @ 120 Vac, 60 Hz
GAS SUPPLY PrESSUrE rEqUIrEmENTS*
Gas Type Manifold Pressure Minimum Gas Supply Pressure
Natural Gas 5” Water Column 6” Water Column
Propane (LP) 10” Water Column 11” Water Column
* Maximum gas supply pressure for all models is 1/2 p.s.i.
IMPORTANT: Installation of a non-combustible material* (up to the hood) or a backsplash is always recommended, and mandatory if the distance to the back wall from the cooktop is less than 2 1/2” (Figure 2). When installing a backguard, use only Dacor model numbers AEB3609, AEB3612 (EG366), AEB4809 or AEB4812 (EG486).
CABINET/COUNTErTOP SIDE vIEw wITHOUT BACkGUArD
CABINET/COUNTErTOP SIDE vIEw wITH BACkGUArDPrODUCT DImENSIONS - SIDE vIEw
PrODUCT DImENSIONS - ISO vIEw
A - WidthEG366 35 7/8” (911 mm)
EG486 47 7/8” (1216 mm)
Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
Document # PG04-001 Revised 05/06/10 Page 1/4
4” (102 mm)5/8”
(16 mm)
7 3/4” (197 mm)
Trim:7/16”
(11 mm)thick26” (660 mm)
1 1/2” (38 mm) cooking surface height (grate level) above
countertop
3/4” gas inlet, connects to regulator from bottom or rear of unit, end is recessed
2” (51 mm) from chassis bottom
27” (686 mm)
28” (711 mm)
Power cord32” long
Combustiblerear wall
Backguard mandatory ifgap from back of cooktopto combustible wall is lessthan 2 1/2”
Combustiblerear wall
2 1/2” (64 mm) Min. tocombustible rear wall
36 Inch and 48 Inch wideEpicure® Gas Cooktops
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.2
See note 2
2 See Cabinet/Countertop Dimensions - Top View 3 Not applicable for cabinets more than a horizontal distance of 10” (254mm) from the edge of the cooktop.
1 Vertical to combustible surface from cooktop grate level;if installing an overhead vent hood, also check the hoodspecifications for minimum required clearances.
C
13” (330 mm) max.3
Top offinishedcounter
18” (457 mm)Min.1, 3
30” (762 mm)Min.1 Cutout for
utility access
Hood
Recommendedgas and electricalservice location,
consult local code
B
10” (254 mm) tocombustible side
wall Min. both sides 1/2” (13 mm)overhang,both sides
1 1/2” (38 mm)typical countertop
thickness
7 3/4” (197 mm)
36” (914 mm)typical
Cooktop platform1” (25 mm) Min.
thickness
Model No. B C
EG366 36” (914 mm) 36” (914 mm)* 42” (1067 mm)**
EG486 48” (1219mm) 48” (1219 mm)* 54” (1372 mm)**
* Minimum ** Recommended
Cabinet tolerances: +1/16”, -0 (+1.6 mm, -0) unless otherwise noted.
CABINET/COUNTErTOP DImENSIONS - FrONT vIEw
CABINET/COUNTErTOP DImENSIONS -ISO vIEw
Continued on following pages...
EG366, EG486Document # PG04-001 Revised 05/06/10 Page 2/4
36 Inch and 48 Inch wideEpicure® Gas Cooktops
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.3
CABINET/COUNTErTOP CUTOUT DImENSIONS wITHOUT rAISED vENT - TOP vIEw
Model No. B - Cutout Width D - Hole OffsetEG366 36” (914 mm) 16 5/8” (422 mm)
EG486 48” (1219 mm) 20 13/16” (529 mm)
Cutout tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
EG366, EG486Document # PG04-001 Revised 05/06/10 Page 3/4
Non-combustible rear wall, rear of
mounting platform
10” (254 mm) min. to combustible wall above countertop,
both sides
Cabinet face below countertop
overhang
Increase countertop and overhang additional 2 1/2” (64 mm) Min. for
combustible rear wall above countertop
3/8” (13 mm) countertop overhang
Hole 1/2” dia. (13 mm), 2 places, through platform
for hold down bolts
Gas/electrical utility cut-out in right rear corner of mounting platform 8” W X 6” D (203 mm X 152 mm),
if gas and electrical are routed through bottom1/2” (13 mm) countertop overhang
1” thick mounting platform Min.
Cou
nter
top
Countertop
1/2” (13 mm) countertop overhang
2” (51 mm)1” (25 mm)
11 7/16” (291 mm)
24 5/8” (625 mm)
CL
D D
B
CL CLCL
Gas connection and power cord may be routed through bottom or back of chassis
Gas and electrical connections at right rear section of chassis
36 Inch and 48 Inch wideEpicure® Gas Cooktops
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.4
CABINET/COUNTErTOP CUTOUT DImENSIONS wITH rAISED vENT - TOP vIEw
CABINET/COUNTErTOP CUTOUT DImENSIONS wITH rAISED vENT - SIDE vIEw
EG366, EG486Document # PG04-001 Revised 05/06/10 Page 4/4
Model No.
B - Cutout Width
D - Hole Offset
E - Raised Vent Cutout
EG366 36” (914 mm)
16 5/8” (422 mm)
33 1/2” (851 mm)
EG486 48” (1219 mm)
20 13/16” (529 mm)
43 1/2” (1105 mm)
Model No.
Approved RaisedVent Models
EG366 ERV36, PRV36
EG486 ERV48, PRV48
Cutout tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
Non combustible rear wall recommended 10” (254 mm) Min. to
combustible wall above countertop,
both sides
Cabinet face below countertop
overhang
3/8” (10 mm) Min. countertop overhang
2 5/8”(67 mm)
Hole 1/2” dia. (13 mm), 2 places, through platform
for hold down bolts
1/2” (13 mm) countertop overhang
1” thick mounting platform Min.
Open to below to allow for raised vent, gas and electrical connections
Cou
nter
top
Countertop
1/2” (13 mm) countertop overhang
2” (51 mm)1” (25 mm)
11 7/16” (291 mm)
15”(381 mm)
24 5/8”(625 mm)
CL
D D
E
B
CL CLCL
Stiffener
Cabinet face
Control panel
Countertop
Dacor approvedraised vent
IMPORTANT: See raised ventinstallation instructions for duct system layout/planning
EG366 or EG486 cooktop
3/8” Min. (10 mm)space behindraised vent chassis to clearstiffener
3/8” Min. (10 mm)flat countertop overhangrequired behind cutout
Minimumcountertop
height: 30 1/4"
(768 mm)
IMPORTANT: Use only the raised vents specified.
36 Inch and 48 Inch wideEpicure® Gas Cooktops
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.5
SGm304, SGm365, SGm466
30”, 36”, 46” wide,Drop-in Gas Cooktops
30"(76.2 cm)
1 5/8" (4.1 cm)bottom of base
to cooking surface
27 5/8" *(70.2 cm)
* including embosses/screws in side of chassis
19 1/2" * (49.5 cm)21"
(53.3 cm)
4" (10.2 cm)chassis height
36"(91.4 cm)
33 1/2" *(85.1 cm)
* including embosses in side of chassis
19 1/2" * (49.5 cm)21"
(53.3 cm)
1 5/8" (4.1 cm)bottom of base
to cooking surface
4" (10.2 cm)chassis height
* including embosses/screws in side of chassis
46"(116.8 cm)
44 5/8" *(113.3 cm)
19 1/2" * (49.5 cm)21"
(53.3 cm)
1 5/8" (4.1 cm)bottom of base
to cooking surface
4" (10.2 cm)chassis height
All tolerances ±1/16” (±1.6 mm), unless otherwise noted.
PrODUCT DImENSIONS - mODEL SGm304
PrODUCT DImENSIONS - mODEL SGm365
PrODUCT DImENSIONS - mODEL SGm466
Document # PG04-004 Revised 01/27/11 Page 1/5
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.6
SGm304, SGm365, SGm466
Electrical Requirements
WARNINGTo prevent an electric shock hazard, the power supply must meet the specifications stated below. It is the owner’s responsibility to make sure that the electrical service meets electrical require-ments and that the electrical outlet has been properly installed.◊ The cooktop is supplied with a factory installed, 40-inch, three-prong,
grounding electrical plug. It is connected to the chassis at the bottom right rear corner (see Chassis Bottom Diagram below). It must be connected to a dedicated, grounded three-prong electrical outlet installed by a licensed electrician.
◊ The electrical installation, including minimum supply wire size and grounding, must be done in accordance with National Electric Code ANSI/NFPA 70* and local codes and ordinances. A copy of this standard may be obtained from:
National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101
◊ The correct voltage, frequency and amperage must be supplied to the electrical outlet according to the product data label located on the bottom of the chassis. See the Gas and Electrical Requirements table on this page for reference.
◊ Be certain to locate the electrical outlet so that the power cord may be easily disconnected if the unit needs service.
Gas Supply Requirements◊ Be certain that the cooktop being installed is correct for the gas
service being provided (natural gas or LP gas). Also, if operating the cooktop at an altitude above 4000 ft. (1219 m) make sure it is equipped for high altitude operation.
◊ Units equipped for LP operation have “LP” in the model number listed on the product data label. See the Chassis Bottom Diagram for label location.
◊ Units equipped for high altitude operation have an “H” at the end of the model number listed on the product data label.
◊ Check your local building codes for the proper method of installation. In the absence of local codes, this appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54.
◊ An external manual shut-off valve must be installed between the gas inlet and the cooktop for the purpose of turning on or shutting off gas to the appliance.
◊ The cooktop comes from the factory with a regulator in the shipping carton. Use only the regulator provided. The regulator must be installed in the gas line that runs from the cooktop gas inlet to the gas shut off valve.
◊ Models SGM304 and SGM365 come with a 1/2” regulator. Model SGM466 comes with a 3/4” regulator, approved for connection to a 1/2” house gas supply.
The cooktop gas connection is located on the bottom of the cootktop in the back right corner as you face the front of the unit. See the Chassis Bottom Diagram on this page.
SGM304 SGM365 SGM466
SGM304LP SGM365LP SGM466LP
Gas type Natural LPG
Manifold pressure 4” Water column 10” Water column
Min. gas supply pressure** 5” Water column 11” Water column
Max. gas supply pressure 1/2 p.s.i. 1/2 p.s.i.
Total connected load 0.25 Amp.(0.03 kW)
0.25 Amp.(0.03 kW)
Circuit requirement 120 Vac,60 Hz, 15 Amp.
120 Vac,60 Hz, 15 Amp.
GAS AND ELECTrICAL rEqUIrEmENTS*
* The electrical and gas data on this page is for reference only. If the above data does not agree with the product data label, use the data on the product data label.** The gas supply pressure for testing the regulator setting shall be at least 1 inch water column (249 Pa) above the specified manifold pressure.
CHASSIS BOTTOm DIAGrAm
Front of unit
Product data label
Electric cordGas inlet
Document # PG04-004 Revised 01/27/11 Page 2/5
30”, 36”, 46” wide,Gas Cooktops
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.7
SGm304, SGm365, SGm466
◊ Allow a minimum 1/4” (6 mm) clearance between the bottom of the cooktop chassis and all combustible surfaces, including the upper edge of a drawer installed below the cooktop.
Model (B) Minimum*
SGM304 29” (73.7 cm)
SGM365 35 1/4” (89.5 cm)
SGM466 46” (116.8 cm)
* To allow clearance for hold down brackets
◊ The gas supply piping, gas shut-off valve and the electrical outlet must be located so they do not interfere with the cooktop when it is installed. If installing another appliance in the cabinet below, allow for the routing of gas and electrical service behind it.
The installation must allow for the following:
◊ Access to the gas shut-off valve and regulator when the unit is installed.
◊ Access to the electrical outlet when the cooktop is in place. The 40” (101.6 cm) power cord must be able to reach the electrical outlet
◊ Access to the underside of the cooktop for service and inspection purposes
◊ Clearance inside the cabinet to allow for proper hold down bracket installation.
To allow access to the utilities and cooktop bottom, a fixed shelf should not be installed below the cooktop. See the following pages for countertop cutout dimensions.
Raised Vent CompatibilityIf installing the cooktop with a raised vent, install only the approved Dacor model numbers specified below:
Cooktop Models Approved Raised Vent Models
SGM304 ERV30, PRV30 or RV30
SGM365 ERV36, PRV36 or RV36
SGM466 PRV46 or RV46
Cabinet and Countertop Layout
WARNING• To reduce the risk of personal injury caused by reaching over
a hot appliance, avoid locating cabinet storage space directly above the cooktop.
• Failure to meet or exceed the maximum and minimum dimensions/clearances stated in these instructions may result in a fire hazard.
• Follow the countertop manufacturer’s instructions regarding the minimum corner radius, use of heat reflective tape, reinforcement of corners, etc.
◊ Carefully check the location where the cooktop will be installed. For best performance, the cooktop should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets.
◊ This appliance is to be used in conjunction with a suitable vent hood or approved Dacor raised vent system.
mINImUm rEqUIrED CLEArANCES ArOUND THE COOkTOP
Model (A) Minimum (A) Recommended
SGM304 30” (76.2 cm) 36” (91.4 cm)
SGM365 36” (91.4 cm) 42” (106.7 cm)
SGM466 48” (121.9 cm) 54” (137.2 cm)
1/4” (6 mm)min. clearanceto combustiblesurfacesB
Under Cabinet Clearances
13" max.3
(33.0 cm)
3 Not applicable for cabinets more than a horizontal distance of 6” (15.2 cm) from edge of cooktop. Allow 7 1/2” (19.1 cm) from edge of cutout.
A
See cutoutdimensions
18" min.1, 3
(45.7 cm)
1 7/8" min. (4.8 cm)
Combustible surface to rear
Combustible overhead cabinets
30" min.1, 2
(76.2 cm)
7 1/2” (19.1 cm) min. to combustible side wall,above counter both sides
2 If installing with an overhead vent hood, also check hood specifications for minimum required clearances.
1 Measured from cooking surface (top of cooktop grate).
Cabinet tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated
Document # PG04-004 Revised 01/27/11 Page 3/5
30”, 36”, 46” wide,Gas Cooktops
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.8
SGm304, SGm365, SGm466
Cutout tolerances +1/16” (+1.6 mm), -0, unless otherwise noted
Countertop Dimensions
Installation Type Cutout Diagram (C) Min. (D) (E) (F) (G) (H)
SGM304 without raised vent
Figure 1(Square)
2 7/8”(7.3 cm)
19 3/4” (50.2 cm)
27 3/4”(68.6 cm) NA NA NA
SGM304 with ERV30 or PRV30
Figure 1(Square)
3/8”(1.0 cm)
22 1/2” * (57.2 cm)
27 3/4”(68.6 cm) NA NA NA
SGM304 with RV30
Figure 1(Square)
5/8”(1.6 cm)
22 1/4” * (56.5 cm)
27 3/4”(68.6 cm) NA NA NA
SGM365 without raised vent
Figure 1(Square)
2 7/8”(7.3 cm)
19 3/4” (50.2 cm)
33 5/8”(85.4 cm) NA NA NA
SGM365 with ERV36 or PRV36
Figure 1(Square)
3/8”(1.0 cm)
22 1/2” * (57.2 cm)
33 5/8”(85.4 cm) NA NA NA
SGM365 with RV36
Figure 1(Square)
5/8”(1.6 cm)
22 1/4” * (56.5 cm)
33 5/8”(85.4 cm) NA NA NA
SGM466 without raised vent
Figure 1(Square)
2 7/8”(7.3 cm)
19 3/4” (50.2 cm)
44 3/4”(113.7 cm) NA NA NA
SGM466 with PRV46
Figure 2(Notched)
3/8”(1.0 cm)
22 1/2” * (57.2 cm)
44 3/4”(113.7 cm)
43 1/2”(110.5 cm)
5/8”(1.6 cm)
2 5/8” **(6.7 cm)
SGM466 with RV46
Figure 2(Notched)
5/8”(1.6 cm)
22 1/4” * (56.5 cm)
44 3/4”(113.7 cm)
43 1/2”(110.5 cm)
5/8”(1.6 cm)
2 5/8” **(6.7 cm)
Stiffener
Cabinet face
Countertop
Floor
3/8” min. (1.0 cm) space behind raised vent chassis to clear stiffener
3/8” min. (1.0 cm)flat countertop overhangrequired behind cutout
ERV or PRV series raised vent: Check raised vent dimensions/specifications to determine proper fit
SGM series cooktopStiffener
Cabinet face
Countertop
Floor
5/8” min. (1.6 cm) space behind raised vent chassis to clear stiffener
4 5/8” (11.7 cm)9 7/8” (25.1 cm) with CABP3 blower installed
5/8” min. (1.6 cm)flat countertop overhangrequired behind cutout
RV series raised vent: Check raised vent dimensions/specifications to determine proper fit
SGM series cooktop
Cutout Dimensions
SIDE vIEw - SGm SErIES COOkTOP wITHErv Or Prv SErIES rAISED vENT
SIDE vIEw - SGm SErIES COOkTOP wITHrv SErIES rAISED vENT
IMPORTANT: Be careful to use the correct cutout diagram (on page 5/5) to determine the countertop dimensions for the installation type. Carefully double check all dimensions against the table below and the correct diagram before cutting the countertop.
* Total cutout depth, accommodates both the cooktop and raised vent ** IMPORTANT: Notch depth is included in total cutout depth (D). DO NOT add notch depth to total cutout depth (D).
Document # PG04-004 Revised 01/27/11 Page 4/5
30”, 36”, 46” wide,Gas Cooktops
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.9
SGm304, SGm365, SGm466
4 1/4" (10.8 cm) min. from mounting surface to combustibles belowcooktop chassis
EC
D
7 1/2" (19.1 cm) min.to combustibleside wall abovecountertop(both sides)
Verticalcombustiblesurface
Rearwall
1 7/8" min.(4.8 cm)
EC
D
H
H
GF
7 1/2" (19.1 cm) min.to combustibleside wall abovecountertop(both sides)
Verticalcombustiblesurface
Rearwall
1 7/8" min.(4.8 cm)
4 1/4" (10.8 cm) min. from mounting surface to combustiblesbelow cooktop chassis
FIGUrE 1 - SqUArE COUNTErTOP CUTOUT DIAGrAm
FIGUrE 2 - NOTCHED COUNTErTOP CUTOUT DIAGrAm
Document # PG04-004 Revised 01/27/11 Page 5/5
30”, 36”, 46” wide,Gas Cooktops
Cutout tolerances +1/16” (+1.6 mm), -0, unless otherwise noted
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.10
rGC304, rGC365
30"(76.2 cm)
2 1/8" (5.4 cm)bottom of base
to cooking surface
27 1/2" *(69.9 cm)
* including embosses in side of chassis
19 1/2" * (49.5 cm)21"
(53.3 cm)
4" (10.2 cm)chassis height
PrODUCT DImENSIONS - mODEL rGC304
Axis2Axis2
36"(91.4 cm)
2 1/8" (5.4 cm)bottom of base
to cooking surface
33 5/8" *(85.4 cm)
* including embosses in side of chassis
19 1/2" * (49.5 cm)
21"(53.3 cm)
4" (10.2 cm)chassis height
PrODUCT DImENSIONS - mODEL rGC365
All tolerances ±1/16” (±1.6 mm) unless otherwise noted.
Document # PG04-005 Revised 01/25/11 Page 1/4
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
30”, 36” wide renaissance Gas Cooktops
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.11
Electrical Requirements
WARNINGTo prevent an electric shock hazard, the power supply must meet the specifications stated below. It is the owner’s responsibility to make sure that the electrical service meets electrical require-ments and that the electrical outlet has been properly installed.◊ The cooktop is supplied with a factory installed, 40-inch power cord
with a, three-prong, grounding electrical plug. It is connected to the chassis at the bottom right rear corner (see Chassis Bottom Diagram below). It must be connected to a dedicated, grounded three-prong electrical outlet installed by a licensed electrician.
◊ The electrical installation, including minimum supply wire size and grounding, must be done in accordance with National Electric Code ANSI/NFPA 70* and local codes and ordinances. A copy of this standard may be obtained from:
National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101
◊ The correct voltage, frequency and amperage must be supplied to the electrical outlet according to the product data label located on the bottom of the chassis. See the Gas and Electrical Requirements table on this page for reference.
◊ Be certain to locate the electrical outlet so that the power may be easily disconnected if the unit needs service.
Gas Supply Requirements◊ Be certain that the cooktop being installed is correct for the gas
service being provided (natural gas or LP gas). Also, if operating the cooktop at an altitude above 4000 ft. (1219 m) make sure it is equipped for high altitude operation.
◊ Units equipped for LP operation have “LP” in the model number listed on the product data label. See the Chassis Bottom Diagram for label location.
◊ Units equipped for high altitude operation have an “H” at the end of the model number listed on the product data label.
◊ Check your local building codes for the proper method of installation. In the absence of local codes, this appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54.
◊ An external manual shut-off valve must be installed between the gas inlet and the cooktop for the purpose of turning on or shutting off gas to the appliance.
◊ The cooktop comes from the factory with a regulator in the shipping carton. Use only the regulator provided. The regulator must be installed in the gas line that runs from the cooktop gas inlet to the gas shut off valve.
◊ The regulator inlet accommodates a 3/4” gas line. The inlet to the cooktop itself is equipped with a 3/4” male NPT fitting.
The cooktop gas connection is located on the bottom of the cootktop in the back right corner as you face the front of the unit. See the Chassis Bottom Diagram on this page.
RGC304 RGC365
RGC304LP RGC365LP
Gas type Natural LPG
Manifold pressure 5” Water column 10” Water column
Min. gas supply Pressure** 6” Water column 11” Water column
Max. gas supply pressure 1/2 p.s.i. 1/2 p.s.i.
Total connected load 0.25 Amp.(0.03 kW)
0.25 Amp.(0.03 kW)
Circuit requirement 120 Vac,60 Hz, 15 Amp.
120 Vac,60 Hz, 15 Amp.
GAS AND ELECTrICAL rEqUIrEmENTS*
* The electrical and gas data on this page is for reference only. If the above data does not agree with the product data label, use the data on the product data label.** The gas supply pressure for testing the regulator setting shall be at least 1 inch water column (249 Pa) above the specified manifold pressure.
rGC304, rGC365
CHASSIS BOTTOm DIAGrAm
Front of unit
Product data label
Electric cordGas inlet
Document # PG04-005 Revised 01/25/11 Page 2/4
30”, 36” wide, renaissance Gas Cooktops
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.12
Cabinet and Countertop Layout
WARNING• To reduce the risk of personal injury caused by reaching over
a hot appliance, avoid locating cabinet storage space directly above the cooktop.
• Failure to meet or exceed the maximum and minimum dimensions/clearances stated in these instructions may result in a fire hazard.
• Follow the countertop manufacturer’s instructions regarding the minimum corner radius, use of heat reflective tape, reinforcement of corners, etc.
◊ Carefully check the location where the cooktop will be installed. For best performance, the cooktop should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets.
◊ This appliance is to be used in conjunction with a suitable vent hood or approved Dacor raised vent system.
mINImUm rEqUIrED CLEArANCES ArOUND THE COOkTOP
Model (A) Min. (A) Recommended
RGC304 30” (76.2 cm) 36” (91.4 cm)
RGC365 36” (91.4 cm) 42” (106.7 cm)
◊ Allow a minimum 1/4” (6 mm) clearance between the bottom of the cooktop chassis and all combustible surfaces, including the upper edge of a drawer installed below the cooktop.
Model (B) Min.*
RGC304 29” (73.7 cm)
RGC365 35 1/4” (89.5 cm)
* To allow clearance for hold down brackets
◊ The gas supply piping, gas shut-off valve and the electrical outlet must be located so they do not interfere with the cooktop when it is installed. If installing another appliance in the cabinet below, allow for the routing of gas and electrical service behind it.
The installation must allow for the following:
◊ Access to the gas shut-off valve and regulator when the unit is installed.
◊ Access to the electrical outlet when the cooktop is in place. The 40” (101.6 cm) power cord must be able to reach the electrical outlet
◊ Access to the underside of the cooktop for service and inspection purposes
◊ Clearance inside the cabinet to allow for proper hold down bracket installation.
To allow access to the utilities and cooktop bottom, a fixed shelf should not be installed below the cooktop. See the following pages for countertop cutout dimensions.
Raised Vent CompatibilityIf installing the cooktop with a raised vent, install only the approved Dacor model numbers specified below:
Cooktop Model Approved Raised Vent Models
RGC304 ERV30, PRV30 or RV30
RGC365 ERV36, PRV36 or RV36
rGC304, rGC365
1/4” (6 mm)min. clearanceto combustiblesurfacesB
Under Cabinet Clearances
13" max.3
(33.0 cm)
3 Not applicable for cabinets more than a horizontal distance of 6” (15.2 cm) (5 1/2” (14.0 cm) for RGC365) from edge of cooktop. Allow 7 1/2” (19.1 cm) from cutout edge for RGC304 and 7” (17.8 cm) for RGC365.
A
18" min.1, 3
(45.7 cm)
1 7/8" min. (4.8 cm)
Combustible surface to rear
Combustible overhead cabinets
30" min.1, 2
(76.2 cm)
See cutout dimensions
See cutoutdimensions
2 If installing with an overhead vent hood, also check the hood specifications for minimum required clearances.
1 Measured from the cooking surface (top of cooktop grate).
All tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated
Document # PG04-005 Revised 01/25/11 Page 3/4
30”, 36” wide, renaissance Gas Cooktops
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.13
rGC304, rGC365
4 1/4" (10.8 cm) min. from mounting surface to combustibles belowcooktop chassis
E
F
C
D
Min. distance to combustible side wall above countertop (both sides)
F
Verticalcombustiblesurface
Rearwall
1 7/8" min.(4.8 cm)
Installation Type (C) Min. (D) (E) (F)RGC304 with no raised vent 2 7/8” (7.3 cm) 19 3/4” (50.2 cm)
27 5/8” (70.1 cm) 7 1/2” (19.0 cm)RGC304 with ERV30 or PRV30 3/8” (1.0 cm) 22 1/2” (57.2 cm)
RGC304 with RV30 5/8” (1.6 cm) 22 1/4” (56.5 cm)
RGC365 with no raised vent 2 7/8” (7.3 cm) 19 3/4” (50.2 cm)
33 3/4” (85.7 cm) 7” (17.8 cm)RGC365 with ERV36 or PRV36 3/8” (1.0 cm) 22 1/2” (57.2 cm)
RGC365 with RV36 5/8” (1.6 cm) 22 1/4” (56.5 cm)
COUNTErTOP CUTOUT DImENSIONS
Stiffener
Cabinet face
Countertop
Floor
3/8” min. (1.0 cm) space behind raised vent chassis to clear stiffener
3/8” min. (1.0 cm)flat countertop overhangrequired behind cutout
ERV or PRV series raised vent: check raised vent dimensions/specifications to determine proper fit
RGC series cooktopStiffener
Cabinet face
Countertop
Floor
5/8” min. (1.6 cm) space behind raised vent chassis to clear stiffener
5/8” min. (1.6 cm)flat countertop overhangrequired behind cutout
RV series raised vent: check raised vent dimensions/specifications to determine proper fit
RGC series cooktop
All tolerances: +1/16” (+1.6 mm), -0, unless otherwise statedCutout Dimensions
SIDE vIEw - rGC SErIES COOkTOP wITHErv/Prv SErIES rAISED vENT
SIDE vIEw - rGC SErIES COOkTOP wITHrv SErIES rAISED vENT
Document # PG04-005 Revised 01/25/11 Page 4/4
30”, 36” wide, renaissance Gas Cooktops
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.14
A
30” and 36” wide, Distinctive Series Slide-in Gas Cooktops
DrT304S, DrT366S
ELECTRIC CIRCUIT REQUIREMENTS
Circuit Required Total Connected Load
120 Vac 60Hz, 15 Amp. (3 wire) 1.0 Amp @ 120 Vac, 60 Hz.
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type Manifold Pressure Minimum Gas Supply Pressure
Natural Gas 5” Water Column 6” Water Column
Propane (LP) 10” Water Column 11” Water Column
* Maximum gas supply pressure for all models is 1/2 p.s.i.
Installation of a non-combustible material* (up to the hood) or a backsplash is always recommended, and mandatory if the distance to the back wall from the cooktop is less than 2 1/2” (Figure 2). When installing a backguard, use only Dacor model numbers AEB3009 (DRT304S), AEB3609 or AEB3612 (DRT366S).
SIDE vIEw wITHOUT BACkGUArD
SIDE vIEw wITHOUT BACkGUArD
SIDE vIEw
Product Dimensions
Electrical and Gas Supply Requirements
Cabinet and Countertop Layout
COOKTOP WIDTH (A)DRT304S 29 7/8” (75.9 cm)
DRT366S 35 7/8” (91.1 cm)
Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
Document # PG04-003 Revised 02/03/11 Page 1/4
4” (10.2 cm) 5/8” min. (1.6 cm)
7 3/4” (19.7 cm)
Trim:1/2”
(1.3 cm)thick25 7/8” (65.7 cm)
1 5/8” (4.1 cm) cooking surface height (grate level) above
countertop
3/4” gas inlet, connects to regulator from bottom or rear of unit, end is recessed
2” (5.1 cm) from chassis bottom
28 1/8” (71.4 cm)
Power cord32” (81.3 cm) long
Combustiblerear wall
Backguard mandatory ifgap from back of cooktopto combustible wall is lessthan 2 1/2”
Combustiblerear wall
2 1/2” (6.4 cm) min. tocombustible rear wall
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.15
See note 2
2 See Cabinet/Countertop Dimensions - Top View 3 Not applicable for cabinets more than a horizontal distance of 10” (25.4 cm) from the edge of the cooktop.
1 Vertical to combustible surface from cooktop grate level;if installing an overhead vent hood, also check the hoodspecifications for minimum required clearances.
C
13” (33.0 cm) max.3
Top offinishedcounter
18” (45.7 cm)min.1, 3
30” (76.2 cm)min.1 Cutout for
utility access
Hood
Recommendedgas and electricalservice location,
consult local code
B
10” (25.4 cm) tocombustible side
wall min. both sides 1/2” (1.3 cm)overhang,both sides
1 1/2” (3.8 cm)typical countertop
thickness
7 3/4” (19.7 cm)
36” (91.4 cm)typical
Cooktop platform1” (2.5 cm) min.
thickness
Model No. B C
DRT304S 30” (76.2 cm) 30” (76.2 cm)* 36” (91.4 cm)**
DRT366S 36” (91.4 cm) 36” (91.4 cm)* 42” (106.7 cm)**
* Minimum ** Recommended
Cabinet tolerances: +1/16”, -0 (+1.6 mm, -0) unless otherwise noted.
CABINET/COUNTErTOP DImENSIONS - FrONT vIEw
CABINET/COUNTErTOP DImENSIONS -ISO vIEw
Continued. on following page...
Cabinet and Countertop Layout (Continued)
DrT304S, DrT366SDocument # PG04-003 Revised 02/03/11 Page 2/4
NOTE: Model DRT304S is not approved for installation with a raised vent.
30” and 36” wide, Distinctive Series Slide-in Gas Cooktops
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.16
DrT304S, DrT366S
CABINET/COUNTErTOP CUTOUT DImENSIONS wITHOUT rAISED vENT - TOP vIEw
Model No. B - Cutout Width D EDRT304S 30” (76.2 cm) 13 3/8” (34.0 cm) 10 1/8” (25.7 cm)
DRT366S 36” (91.4 cm) 16 5/8” (42.2 cm) 11 3/16” (28.4 cm)
Cutout tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated
Document # PG04-003 Revised 02/03/11 Page 3/4
Cabinet and Countertop Layout (Continued)
Non-combustible rear wall, rear of
mounting platform
10” (25.4 cm) min. to combustible wall above countertop,
both sides
Cabinet face below countertop
overhang
Increase countertop and overhang additional 2 1/2” (6.4 cm) min. for
combustible rear wall above countertop
3/8” (1.3 cm) countertop overhang
Hole 1/2” dia. (1.3 cm), 2 places, through platform
for hold down bolts
Gas/electrical utility cut-out in right rear corner of mounting platform 8” W X 6” D (20.3 cm X 15.2 cm),
if gas and electrical are routed through bottom1/2” (1.3 cm) countertop overhang
1” thick mounting platform min.
Cou
nter
top
Countertop
1/2” (1.3 cm) countertop overhang
2” (5.1 cm)1” (2.5 cm)
E
24 5/8” (62.5 cm)
D D
B
CL
Gas connection and power cord may be routed through bottom or back of chassis
Gas and electrical connections at right rear section of chassis
30” and 36” wide, Distinctive Series Slide-in Gas Cooktops
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.17
Stiffener
Cabinet face
Control panel
Countertop
Use Dacor raisedvent, model ERV3615 only IMPORTANT: See raised vent
installation instructions for duct system layout/planning
DRT366 cooktop
3/8” min. (1.0 cm)space behindraised vent chassis to clearstiffener
3/8” min. (1.0 cm)flat countertopoverhang required behind cutout
Minimumcountertop
height: 30 1/4"
(76.8 cm)
28 5/16” (71.9 cm)
Non combustible rear wall recommended 10” (2.5 cm) min. to
combustible wall above countertop,
both sides
Cabinet face below countertop
overhang
3/8” (1.0 cm) min. countertop overhang
2 5/8”(6.7 cm)
Hole 1/2” dia. (1.3 cm), 2 places, through platform
for hold down bolts
1/2” (1.3 cm) countertop overhang
1” (2.5 cm) thick mounting platform min.
Open to below to allow for raised vent, gas and electrical connections
Cou
nter
top
Countertop
1/2” (1.3 cm) countertop overhang
2” (5.1 cm)1” (2.5 cm)
15”(38.1 cm)
24 1/2”(62.2 cm)
D
E
D
F
B
CLCABINET/COUNTErTOP CUTOUT DImENSIONS wITH rAISED
vENT - TOP vIEw
CABINET/COUNTErTOP CUTOUT DImENSIONS wITH rAISED
vENT - SIDE vIEw
Model No.*
B - Cutout Width D E F - Raised
Vent Cutout
DRT366S 36” (91.4 cm)
16 5/8” (42.2 cm)
11 3/16” (28.4 cm)
33 1/2” (85.1 cm)
* Model DRT304 is not approved for use with a raised vent. ** Use only raised vent model specified. Raised vent is not compatible with DRT cooktops having a serial number starting with letters “SA.”
Cutout tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated
DrT304S, DrT366SDocument # PG04-003 Revised 02/03/11 Page 4/4
Cabinet and Countertop Layout (Continued)
30” and 36” wide, Distinctive Series Slide-in Gas Cooktops
NOTE: Gas and electrical connections may only be routed through the bottom of the cooktop when installed with a raised vent.
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.18
DCT305, DCT365
A2" (5.1 cm)countertop
to cooking surface
21"(53.3 cm)
4" (10.2 cm)chassis height
Product Dimensions
Front of unit
Power cord 42” (106.7 cm) long
1/2” maleNPT gas inlet
2”(5.1 cm)
1 3/4”(4.4 cm)
1/2” male NPT gas inlet*
Power cord in
Chassis
Front of cooktop
Top panel overhang
*Gas inlet protudes 1/2” (1.3 cm) from bottom
1 3/4”(4.4 cm)
UTILITY LOCATIONS UTILITY DImENSIONS
Product tolerances ±1/16” (±1.6 mm) unless otherwise noted.
Document # PG04-006 Revised 08/19/11 Page 1/4
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
30” and 36” wide, Distinctive Series Drop-in Gas Cooktops
Side View
Rearoverhang
Frontoverhang
19 9/32” (49.0 cm)
17/32”(1.3 cm)
1 3/16”(3.0 cm)
Front View
B
1 11/32”(3.4 cm)
1 11/32”(3.4 cm)
Model (A) (B)DCT305 30” (76.2 cm) 27 5/16” (69.4 cm)
DCT365 36” (91.4 cm) 33 5/16” (57.8 cm)
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.19
Electrical Requirements
WARNINGTo prevent an electric shock hazard, the power supply must meet the specifications stated below. It is the owner’s responsibility to make sure that the electrical service meets electrical require-ments and that the electrical outlet has been properly installed by a licensed electrician.◊ The cooktop is supplied with a factory installed, 42 inch power cord
with a, three-prong, grounding electrical plug. It is connected to the chassis at the bottom right rear corner (see Chassis Bottom Diagram below). It must be connected to a dedicated, grounded three-prong electrical outlet installed by a licensed electrician.
◊ The electrical installation, including minimum supply wire size and grounding, must be done in accordance with National Electric Code ANSI/NFPA 70* and local codes and ordinances. A copy of this standard may be obtained from:
National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101
◊ The correct voltage, frequency and amperage must be supplied to the electrical outlet according to the product data label located on the bottom of the chassis. See the Gas and Electrical Requirements table on this page for reference.
◊ Be certain to locate the electrical outlet so that the power may be easily disconnected if the unit needs service.
Gas Supply Requirements◊ Be certain that the cooktop being installed is correct for the gas
service being provided (natural gas or LP gas). Also, if operating the cooktop at an altitude above 4000 ft. (1219 m) make sure it is equipped for high altitude operation.
◊ Units equipped for LP operation have “LP” in the model number listed on the product data label. See the Chassis Bottom Diagram for label location.
◊ Units equipped for high altitude operation have an “H” at the end of the model number listed on the product data label.
◊ Check your local building codes for the proper method of installation. In the absence of local codes, this appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54.
◊ An external manual shut-off valve must be installed between the gas inlet and the cooktop for the purpose of turning on or shutting off gas to the appliance.
◊ The cooktop comes from the factory with a regulator in the shipping carton. Use only the regulator provided. The regulator must be installed in the gas line that runs from the cooktop gas inlet to the gas shut off valve.
◊ The regulator inlet accommodates a 3/4” gas line. The inlet to the cooktop itself is equipped with a 3/4” male NPT fitting.
The cooktop gas connection is located on the bottom of the cootktop in the back right corner as you face the front of the unit. See the Chassis Bottom Diagram on this page.
DCT304_NG DCT365_NG
DCT304_LP DCT365_LP
Gas type Natural LP gas
Manifold pressure 5” water column 10” water column
Min. gas supply Pressure** 6” water column 11” water column
Max. gas supply pressure 1/2 psi 1/2 psi
Total connected load 0.25 Amp.(30 Watts)
0.25 Amp.(30 Watts)
Circuit requirement 120 Vac,60 Hz, 15 Amp.
120 Vac,60 Hz, 15 Amp.
GAS AND ELECTrICAL rEqUIrEmENTS*
* The electrical and gas data on this page is for reference only. If the above data does not agree with the product data label, use the data on the product data label.** The gas supply pressure for testing the regulator setting shall be at least 1 inch water column (249 Pa) above the specified manifold pressure.
DCT305, DCT365
CHASSIS BOTTOm DIAGrAm
Front of unit
Product data label
Document # PG04-006 Revised 08/19/11 Page 2/4
30” and 36” wide, Distinctive Series Drop-in Gas Cooktops
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.20
Cabinet and Countertop Layout
WARNING• To reduce the risk of personal injury caused by reaching over
a hot appliance, avoid locating cabinet storage space directly above the cooktop.
• Failure to meet or exceed the maximum and minimum dimensions/clearances stated in these instructions may result in a fire hazard.
• Follow the countertop manufacturer’s instructions regarding the minimum corner radius, use of heat reflective tape, reinforcement of corners, etc.
◊ Carefully check the location where the cooktop will be installed. For best performance, the cooktop should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets.
◊ This appliance is to be used in conjunction with a suitable vent hood or approved Dacor raised vent system.
mINImUm rEqUIrED CLEArANCES ArOUND THE COOkTOP
Model (A) Minimum (A) RecommendedDCT305 30” (76.2 cm) 36” (91.4 cm)
DCT365 36” (91.4 cm) 42” (106.7 cm)
◊ Allow a minimum 1/4” (6 mm) clearance between the bottom of the cooktop chassis and all combustible surfaces, including the upper edge of a drawer installed below the cooktop.
Model (B) MinimumDCT305 29 1/4” (74.3 cm)
DCT365 35 1/4” (89.5 cm)
◊ The gas supply piping, gas shut-off valve and the electrical outlet must be located so they do not interfere with the cooktop when it is installed. If installing another appliance in the cabinet below, allow for the routing of gas and electrical service behind it.
The installation must allow for the following:
◊ Access to the gas shut-off valve and regulator when the unit is installed.
◊ Access to the electrical outlet when the cooktop is in place. The 42” (106.7 cm) power cord must be able to reach the electrical outlet
◊ Access to the underside of the cooktop for service and inspection purposes
◊ Clearance inside the cabinet to allow for proper hold down bracket installation.
To allow access to the utilities and cooktop bottom, a fixed shelf should not be installed below the cooktop. See the following pages for countertop cutout dimensions.
Raised Vent CompatibilityModel DCT305 is not compatible with a raised vent. If installing cooktop model DCT365 with a raised vent, install only Dacor raised vent model ERV3615. Installation of any other raised vent model may cause improper operation.
DCT305, DCT365
1/4” (6 mm)mimimum clearanceto combustiblesurfaces
B
* Allows for clearance between hold down brackets
13” max.3
(33.0 cm)
3 This specification does not apply for cabinets located greater than a horizontal distance of 5 1/2” (14.0 cm) from edge of cooktop. Allow 6 7/8” (17.5 cm) from cutout edge.
A
1 5/8” min. (4.1 cm)
Combustible surface to rear
30” min.1, 2
(76.2 cm)
See cutoutdimensions
See cutoutdimensions
2 If installing with an overhead range hood, check the hood specifications for minimum required clearances.
1 Distance to combustible surfaces measured from cooking surface (top of cooktop grate).
18” min.1, 3
(45.7 cm)
Cabinet tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated
Document # PG04-006 Revised 08/19/11 Page 3/4
30” and 36” wide, Distinctive Series Drop-in Gas Cooktops
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 4.21
DCT305, DCT365
4 1/4” (10.8 cm) min. from mounting surface to combustibles belowcooktop chassis
E
F
C
D
Minimum distance to combustible side wall above countertop (both sides)
F
Verticalcombustiblesurface
Rearwall
1 5/8” min.(4.1 cm)
Installation Type (C) Minimum (D) (E) (F) MinimumDCT305* 3 1/4” (8.3 cm) 19 5/8” (49.9 cm) 27 5/8” (85.4 cm)
6 7/8” (17.5 cm)DCT365 with no raised vent 3 1/4” (8.3 cm) 19 5/8” (49.9 cm)33 5/8” (85.4 cm)
DCT365 with ERV3615 raised vent 3/8” (1.0 cm) 22 3/4” (57.8 cm)
* Model DCT305 is not compatible with a raised vent
Stiffener
Cabinet face
Countertop
Floor
3/8” min. (1.0 cm) space behind raised vent chassis to clear stiffener
3/8” min. (1.0 cm)flat countertop overhangrequired behind cutout
ERV3615 raised vent.Check raised vent dimensions/specifications to determine proper fit
DCT365 cooktop
Cabinet tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated
Cutout Dimensions
SIDE vIEw - DCT365 COOkTOP wITH Erv3615 rAISED vENT
Document # PG04-006 Revised 08/19/11 Page 4/4
30” and 36” wide, Distinctive Series Drop-in Gas Cooktops
Raised Vent CompatibilityIf installing cooktop DCT365 with a raised vent, install only Dacor raised vent model ERV3615. Installation other any other model raised vent may cause improper operation.
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.1
Er30G, Er30GI
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
All tolerances ±1/16” (±1.6mm) unless otherwise noted.
1 1/8” (29mm)
1 9/16”(40mm)
2” (51mm)
3” (76mm)
Front of open doorFront of handleFront edge of bullnoseFront panelRear of front panel
Backguard thickness
26 1/8” (664mm)27 1/16” (687mm)28 9/16” (725mm)
24” (610mm)
3” (76mm)Backguard***
ER30G:Full stainless
steel side panels
ER30GI:Partial stainless steel side panel
Grates extend1” above trim
6” (152mm)Backguard*
1 3/4” (44mm) Backguard**
***
**
*
Optional on both models, NOT compatible with self-rimming installations
Standard on model ER30GOptional on model ER30GI, NOTcompatible with self-rimming installations Standard on model ER30GIOptional on model ER30G
Product width:29 7/8” (759mm)
ER30G is designed for freestanding install-ations. ER30GI is designed for installation in a recessed cabinet or island. ER30G is NOT equipped for self-rimming installation.
NOTE: Neither model is compatible with a raised vent.
35”(889mm)
to37 1/8”
(943mm)
9” (229mm)Backguard***
45 9/16” (1157mm)
Er30G/Er30GI OvErALL DEPTH DImENSIONS - SIDE vIEw
Electrical Circuit Required
Total Connected Load
120 Vac, 60 Hz, 15 Amps., dedicated, grounded
4.0 Amps. @ 120 Vac, 60 Hz
ELECTrICAL rEqUIrEmENTS
Document # PG05-001 Revised 05/25/10 Page 1/3
30” wide, Epicure®
All Gas range
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.2
Er30G, Er30GI
All tolerances +1/16” -0 (+1.6mm, 0) unless otherwise noted.
A* B C
30 1/16” (764mm) 30” (762mm) Minimum36” (914mm) Recommended
37 1/8” (943mm) Maximum
Note 2
2 Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See product dimesions. 3 Consult local code for exact location requirements.4 Not applicable for cabinets more than a horizontal distance of 10” (254mm) from the edge of the range.
1 Vertical to combustible surface from range grate level
B
A
Non-combustible surface along back wallrecommended
10” (254mm Min.to combustible sidewalls above the range(both sides)
Top offinishedcounter
Suggested location of utilities3
30” (762mm)Min.1
13” (330mm)Max.4
18” (457mm)Min.1, 4
C
SLIDE-IN CUTOUT DImENSIONS
SELF-rImmING CUTOUT DImENSIONS - CABINET DEPTH GrEATEr THAN 24 INCHES
(Er30GI ONLY)
SELF-rImmING CUTOUT DImENSIONS - CABINET DEPTH ExACTLY 24 INCHES
(Er30GI ONLY)
non comubustible rear wall recommended
Countertop Height: Min: 34 3/4” (883mm) Max: 36 7/8” (937mm) Countertop Thickness: Max: 1 5/8” (41mm)
countertop opening29 1/4” (743mm)
30” (762mm)cabinet openingbelow countertop
below countertopCabinet face
Notch countertopoverhang to width of
cabinets
10” Min. (254mm)to any combustibles above counter both sides
Countertop overhang 2 1/8” (54mm) Max.
24” (610mm)
rear wall orcountertop edge
Countertop Height: Min: 34 3/4” (883mm) Max: 36 7/8” (937mm) Countertop Thickness: Max: 1 5/8” (41mm)
countertop opening29 1/4” (743mm)
30” (762mm)cabinet openingbelow countertop
below countertopCabinet face
Notch countertopoverhang to width of
cabinets
3/4” Min. (19mm) Countertop overhang
10” Min. (254mm)to any combustibles above counter both sides
Countertop overhang 2 1/8” (54mm) Max.
24 1/8” (613mm)
* See the cutout dimensions below for self-rimming installations
Document # PG05-001 Revised 05/25/10 Page 2/3
NOTE: Self-rimming kit is included with model ER30GI. The self-rimming kit allows the trim to overlap the counter top on the sides and back.
30” wide, Epicure®
All Gas range
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.3
Er30G, Er30GI
12 1/2”(318 mm)
to14 5/8”
(371 mm)2 5/8”
(67 mm)CL
CL10” (
254m
m)
10” (
254m
m)
12” (305mm)
2 1/2”(64mm)
3 1/2”(89mm)
1” (25mm)
BACk OF rANGE UTILITY CLEArANCE BEHIND rANGE
GAS SUPPLY PRESSURE REQUIREMENTSGas Type
Manifold Pressure* (WC)
Min. Gas Supply Pressure (WC)
Max. Input Pressure
Natural 5” 6” 1/2 p.s.i.LP 10” 11” 1/2 p.s.i.
IMPORTANT: The information above is for reference only. If the above data does not agree with the product data label, use the data on the product data label on top of the kick plate below the door (remove the door according to the installation instructions to view it).The gas connection is located on the back of the unit as shown. Use a 1/2" male NPT to connect to the regulator.
Document # PG05-001 Revised 05/25/10 Page 3/3
30” wide, Epicure®
All Gas range
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.4
36” wide, Epicure®
Gas range
Er36G, Er36GIDocument # PG05-002 Revised 05/25/10 Page 1/3
WARNING• Observe all governing codes and ordinances during
planning and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
All tolerances ±1/16” (±1.6 mm) unless otherwise noted.
1 9/16”(40 mm)
2” (51 mm)1
3” (76 mm)
Front of open doorFront of handleFront edge of bull noseFront panelRear of front panel7
26 3/4” (679 mm)27 13/16” (706 mm)29” (736 mm)
24 5/8” (625 mm)
ER36G:Full stainless
steel side panels
ER36GI:Partial stainless steel side panel
Grates extend1” above trim
Product Width: 35 7/8” (911 mm)
35 3/4”(908 mm)
to37 7/8”
(962 mm)
46 7/8” (1191 mm)
1 1/4” (32 mm)
15 1/4” (387 mm)
A
BC
D19” (482 mm)
9” (229 mm)
(A) 1 3/4” (44 mm): Model AER36GLBG (low profile) 2 (B) 6” (152 mm): Model AER36GBG6 3, 5
(C) 9” (229 mm): Model AER36GBG9 4, 5
(D) 24” (610 mm): Model AER36GBG24 4, 5
Er36G/Er36GI DImENSIONS SIDE vIEw
Er36G/Er36GI AvAILABLE BACkGUArDS
Electrical Circuit Required
Total Connected Load
120 Vac, 60 Hz, 15 Amp. grounded, dedicated, 3 prong
electrical outlet
5.0 Amps. @120 Vac, 60 Hz,
ELECTrICAL rEqUIrEmENTS
NOTES:1. Trim thickness is 1/4” (6 mm) with optional self-rimming kit
installed (ER36GI only).2. Standard on model ER36GI. Optional on model ER36G.3. Standard on model ER36G. Optional on model ER36GI.4. Optional on both models.5. Not for use with self rimming installations. ER36G is not
equipped for self-rimming installation.6. ER36G is designed for freestanding installations. ER36GI is
designed for installation in a recessed cabinet or island.7. This dimension is shortened to 24 inches when the self-
rimming kit is installed (ER36GI only).
NOTE: Neither model is compatible with raised vents.
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.5
Er36G, Er36GI
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.
NOTES:1. Utilities may be located in the lower left corner
of the adjacent right cabinet (recommended). Consult local code.
2. Self-rimming kit is included with model ER36GI. The self-rimming kit allows the trim to overlap the counter top on the sides and back. ER36G is not equipped for self-rimming installation.
A * B C
36 1/16” (916 mm) 30” (762 mm) Minimum36” (914 mm) Recommended
37 7/8” (962 mm) Maximum
Note 2
2 Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See product dimesions. 3 Consult local code for exact location requirements.4 Not applicable for cabinets more than a horizontal distance of 10” (254mm) from the edge of the range.
1 Vertical to combustible surface from range grate level
B
A
Non-combustible surface along back wallrecommended
10” (254mm Min.to combustible sidewalls above the range(both sides)
Top offinishedcounter
Suggested location of utilities3
30” (762mm)Min.1
13” (330mm)Max.4
18” (457mm)Min.1, 4
C
CABINET CUTOUT DImENSIONS
SELF-rImmING CUTOUT DImENSIONS - CABINET DEPTH GrEATEr THAN 24 INCHES
(Er36GI ONLY)
SELF-rImmING CUTOUT DImENSIONS - CABINET DEPTH ExACTLY 24 INCHES
(Er36GI ONLY)
non comubustible rear wall recommended
Countertop Height: Min: 35 1/2” (902 mm) Max: 37 5/8” (956 mm) Countertop Thickness: Max: 1 5/8” (41mm)
countertop opening35 1/4” (895 mm)
36” (914 mm)cabinet openingbelow countertop
below countertopCabinet face
Notch countertopoverhang to width of
cabinets
10” Min. (254mm)to any combustibles above counter both sides
Countertop overhang 2 1/8” (54 mm) Max.
24” (610mm)
rear wall orcountertop edge
Countertop Thickness: Max: 1 5/8” (41mm)
countertop opening
cabinet openingbelow countertop
below countertopCabinet face
Notch countertopoverhang to width of
cabinets
3/4” Min. (19mm) Countertop overhang
10” Min. (254mm)to any combustibles above counter both sides
Countertop overhang 2 1/8” (54mm) Max.
24 1/8” (613mm)
Countertop Height: Min: 35 1/2” (902 mm) Max: 37 5/8” (956 mm)
35 1/4” (895 mm)
36” (914 mm)
* See the Cutout dimensions below for self-rimming installations
Document # PG05-002 Revised 05/25/10 Page 2/3
36” wide, Epicure®
Gas range
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.6
CL
CL12 1
/2” (
318
mm
)
15” (
381
mm
)
12” (305mm)
2 1/2”(64mm)
3 1/2”(89mm)
1” (25mm)
Er36G, Er36GI
15 7/8”(403 mm)
to18”
(457 mm)3 3/4”
(95 mm)
BACk OF rANGE
GAS SUPPLY PRESSURE REQUIREMENTSGas Type
Manifold Pressure* (WC)
Min. Gas Supply Pressure (WC)
Max. Input Pressure
Natural 5” 6” 1/2 p.s.i.LP 10” 11” 1/2 p.s.i.
Document # PG05-002 Revised 05/25/10 Page 3/3
IMPORTANT: The information above is for reference only. If the above data does not agree with the product data label, use the data on the product data label on top of the kick plate below the door (remove the door according to the installation instructions to view it).The gas connection is located on the back of the unit as shown. Use a 1/2" male NPT to connect to the regulator.
UTILITY CLEArANCE BEHIND rANGE
36” wide, Epicure®
Gas range
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.7
Epicure® ranges
Er30D, Er30DSr
ELECTRIC CIRCUIT REQUIREMENTS
Range Model Circuit RequiredTotal Connected
Load
ER30D/ER30DSR 240 Vac, 4-wire* 60 Hz, 30 Amp. 5.6 kW (24.2 Amp.)
The ratings above are for reference only - refer to the range rating label
NOTE: Models ER30D and ER30D-C are NOT designed for use with self-rimming installations or raised vents. Use model ER30DSR for self-rimming and raised vent installations.
NOTE:
■ Self-rimming models are designed to allow the trim to overlap the countertop when configured to the dimensions on page 1/3.
■ Self-rimming models are not compatible with integral backguards
1 9/16”(40 mm)
23 1/8” (587 mm)24 1/8” (613 mm)
27 3/16” (691 mm)
35 3/4”(908 mm)
to37 7/8”
(962 mm)
28 11/16” (729 mm)46 1/8” (1172 mm)
Rear of front panel to back of chassis
Rear of front panel /oven doorFront panelFront edge of bullnoseFront of handleFront of open door
26 3/16” (665 mm)
Width at front panel: 29 7/8” (758 mm)
1 5/16” (33 mm) to cookingsurface (top of grates) frombottom of trim
SELF rImmING mODEL Er30DSr SIDE DImENSIONS
wITH OPTIONAL rAISED vENT TrIm kIT INSTALLED (ATk30Sr)
1 1/16” (27 mm)
26 5/16” (668 mm)27 5/16” (694 mm)
28 13/16” (732 mm)
24 1/4” (616 mm)
3” (76 mm)Backguard*
6” (152 mm)Backguard**
** Optional Standard*
37 7/8”(962 mm)
to
35 3/4”(908 mm)
46 1/4” (1175 mm)
Width at front panel: 29 7/8” (758 mm)
Finished side panel
9” (229 mm)
1 9/16” (40 mm)
Backguard**
1 1/16” (27 mm) to cookingsurface (top of grates) fromtop of trim
FrEESTANDING mODELS Er30D AND Er30D-C
1 9/16”(40 mm)
23 1/8” (587 mm)23 5/8” (600 mm)
26 11/16” (678 mm)
35 3/4”(908 mm)
to37 7/8”
(962 mm)
28 3/16” (716 mm)45 5/8” (1159 mm)
Rear of front panel to back of chassis
Rear of front panel /oven doorFront panelFront edge of bullnoseFront of handleFront of open door
25 11/16” (652 mm)
Width at front panel: 29 7/8” (758 mm)
1 5/16” (33 mm) to cookingsurface (top of grates) frombottom of trim
SELF rImmING mODEL Er30DSrSIDE DImENSIONS
wITH STANDArD TrIm
Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated
WARNING• Observe all governing codes and ordinances during
planning and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
Document # PG05-003 Revised 02/03/11 Page 1/3
* 4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.8
Epicure® ranges
Er30D, Er30DSr
Note 2
F
G
2 Cabinet/countertop depth is at discretion of customer but cabinet face MUST NOT protrude further than rear of front panel, see product dimensions.3 Consult local code for exact location requirements.
1 Vertical to combustible surface from range grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances.
Non-combustible surface along
back wallrecommended
10” (254 mm) Min.to combustible sidewalls above the range(both sides)
30” (762 mm)Min.1
36 1/2” (927 mm)
Max.
13” (330 mm)Max.4
18” (457 mm)Min.1, 4
Suggested location of utilities
3
4 Not applicable for cabinets more than a horizontal distance of 10” (254 mm) from the edge of the range.
CUT-OUT DIMENSIONSF G
36” (914 mm)* 30” (762 mm)** 30 1/16” (916 mm)*
* Recommended ** Minimum
Gas and Electrical Service ■ The shaded area (diagram bottom left) denotes the location of
the gas inlet and the electrical junction box/receptacle. This is the recommended location. For replacement purposes, the location of the existing utilities may be utilized provided they do not interfere with the sides or rear of the range. Check local building codes for permissible gas valve and electrical locations.
■ An external manual shut-off valve must be installed between the gas inlet and the range, for the purpose of turning on or shutting off gas to the appliance.
The installation must allow for the following: ■ Access to the gas shut-off valve when the unit is installed.
■ Access to the remote circuit breaker panel/fuse box, when the range is in place.
■ The gas supply piping and shut-off valve, and the electrical junction box/receptacle must be located so they do not interfere with the range when it is installed.
■ The junction box and gas shut off valve must be located so that the range can be pulled out for service while the appliance remains connected.
CABINET CUTOUT DImENSIONS mODELS Er30D AND Er3OD-C
NOTE: See following page for countertop/cabinet cutout dimensions for self-rimming installations
Cabinet tolerances: +1/16”, (+1.6 mm) -0
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type Manifold Pressure Minimum Gas Supply Pressure
Natural Gas 5” Water Column 6” Water Column
Petroleum (LP) 10” Water Column 11” Water Column
* Maximum input gas supply pressure for all models is 1/2 p.s.i.
GAS - ELECTRICAL ACCESS DIMENSIONS
A B C D E
4 7/8”(124 mm)
21 3/4”(552 mm)
8 5/8”(219 mm)
10 3/16”(259 mm)
7/8”*(22 mm)
* The hole size can be increased to 1 1/8” by removing the conduit bracket inside the range electrical access box.
B
Gas inlet
AC
7/8” (22 mm) Dia. electrical connection hole in bottom*
D
Range electrical access, cover removed
BACk OF rANGE
Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated
Document # PG05-003 Revised 02/03/11 Page 2/3
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.9
Epicure® ranges
Er30D, Er30DSr
ER30DSR with H J K
no side panels no raised vent 23 1/2” (597 mm) 23 1/2” (597 mm) 24” to 25 9/16”
3-inch side panels* and no raised vent 20 1/2” (521 mm) 20 1/2” to 23 1/2” 21” to 25 9/16”
no side panels and raised vent 24” (610 mm) 24” (610 mm) 24 1/2” to 26 1/16”
3-inch side panels and raised vent 21” (533 mm) 21” to 24” 21 1/2” to 26 1/16”
Cutout tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
TOP vIEw - mODEL Er30DSr COUNTErTOP/CABINET CUTOUT DImENSIONS SELF rImmING INSTALLATION
Non-combustiblerear wall recommeded
Countertop Height: Min: 35 5/8” (905 mm) Max: 37 3/8” (949 mm)
Combustible sidewall above range
countertop opening29 1/2” (749 mm)
30” (762 mm)cabinet openingbelow countertop
below countertopCabinet face
Notch countertopoverhang to width of
cabinets
1/4” Min. (6 mm) Countertopoverhang
10” Min.(254 mm)both sides
Countertop front
H J K
rear wall recommendedNon-combustible
countertop opening
cabinet openingbelow countertop
29 1/2” (749 mm)
27 1/2” (699 mm)
30” (762 mm)
2 3/8” (60 mm)
Combustible sidewall above range
10” Min.(254 mm)both sides
Countertop Height: Min: 35 5/8” (905 mm) Max: 37 1/4” (946 mm)
Notch countertopoverhang to width of
cabinets
3/8” Min. (10 mm)Countertopoverhang
below countertopCabinet face
raised vent opening
H J K
Countertop front
TOP vIEw - mODEL Er30DSr COUNTErTOP/CABINET CUTOUT DImENSIONS, SELF rImmING INSTALLATION wITH rAISED vENT (ATk30Sr TrIm kIT INSTALLED)
APPrOvED rAISED vENTS: Erv30 Or Prv30
Stiffener Cabinet face*
Countertop*
* IMPORTANT: See Countertop/Cabinet Cutout Dimensions for countertop cutout dimensions.
** IMPORTANT: If optional 3-inch side panels are not installedcabinet face must be flush with back of control panel.
Back ofcontrolpanel
ERV30 orPRV30raised vent
ER30DSR range: ATK30SR trim kit required for installationwith raised vent
3/8” Min. (10 mm)space behindraised vent chassis to clearstiffener
3/8” Min. (10 mm)flat countertopoverhang required behind cutout
Shown withoptional 3-inchside panelsinstalled**
Countertop height:35 5/8" (905 mm) Min.37 1/4” (946 mm) Max.
28 3/4” (730 mm)
Document # PG05-003 Revised 02/03/11 Page 3/3
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.10
Epicure® ranges
Er36D, Er48D
GAS - ELECTRICAL ACCESS DIMENSIONS
Model A B C D E*
ER36D 5 5/8” (142.9 mm)
18 3/8” (466.7 mm)
10 3/4” (273.0 mm)
13 11/16” (347.7 mm)
7/8” (22.2 mm)
ER48D 3 13/16” (96.8 mm)
18 11/16” (474.7 mm)
9 3/8” (238.1 mm)
13 3/4” (349.3 mm)
1 1/8” (28.6 mm)
* The diameter on models equipped for use in Canada is ¼” (6.4mm) larger than those stated. Canadian units come from the factory pre-wired with an appliance cord. When installing an appliance cord on models that are not pre-wired, the hole size must be increased to 1 1/8” (1 3/8” for model ER48D) by removing the conduit bracket inside the range electrical access box.
48” (1219 mm) Front of open doorFront of handleFront edge of bull noseFront panelRear of front panel/oven door
30 3/4” (781 mm)
(483 mm)
(908 mm)
(940 mm)
(76 mm)
24” (610 mm)(51 mm)
(387 mm)
(40 mm)
(229 mm)
(229 mm)
29 3/8” (746 mm)28 1/4” (718 mm)26 1/8” (664 mm)
**
**
**
** Optional
1 1/16” (27 mm) to cookingsurface (top of grates) fromtop of trim
Finished sidepanel
Width: ER36D - 35 7/8” (911 mm) ER48D - 47 7/8” (1216 mm)
B
A
C
D
Gas regulator access, cover removed
Range electrical access, cover removed
E Electrical connection hole in bottom
InletBack of range
Product tolerances: +/- 1/16” (+/- 1.6 mm) unless otherwise stated
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type Manifold Pressure Minimum Gas Supply Pressure
Natural Gas 5” Water Column 6” Water Column
Propane (LP) 10” Water Column 11” Water Column
* Maximum gas supply pressure 1/2 p.s.i. for all models
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
ELECTRIC CIRCUIT REQUIREMENTS
Range Model Circuit Required Total Connected Load
ER36D240 Vac, 4-wire* 60 Hz, 30
Amp. (Min.) 40 Amp. (Recommended)
6.5 kW (28 Amp.)
ER48D 240 Vac, 4-wire* 60 Hz, 50 Amp. 10.0 kW (42 Amp.)
* 4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground
Document # PG05-004 Revised 04/21/10 Page 1/2
OVEN INTERIOR SPECIFICATIONSModel Number Dimensions Volume
ER36D 15" H x 29" W x 19 ½" D 4.9 ft3
ER48D - Small oven 15" H x 15" W x 19 ½" D 2.5 ft3
ER48D - Large oven 15" H x 27" W x 19 ½" D 4.6 ft3
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.11
Epicure® ranges
Er36D, Er48D
CUT-OUT DIMENSIONSRange Model F G H
ER36D 42” (1067 mm)* 36” (914 mm)**
36 1/16” (916 mm)**
33 1/2” (848 mm)
ER48D 54” (1372 mm)* 48” (1219 mm)**
48 1/16” (1221 mm)**
43 1/2” (1102 mm)
* Recommended **Minimum
Gas and Electrical Service ■ For replacement purposes, the location of the existing utilities may
be utilized provided they do not interfere with the sides or rear of the range. Check local building codes for permissible locations.
■ An external manual shut-off valve must be installed between the gas inlet and the range, for the purpose of turning on or shutting off gas to the appliance.
The installation must allow for the following:
■ Access to the gas shut-off valve when the unit is installed.
■ Access to the remote circuit breaker panel/fuse box, when the range is in place.
■ The gas supply piping and shut-off valve, and the electrical junction box/receptacle must be located so they do not interfere with the range when it is installed.
■ The junction box and gas shut off valve must be located so that the range can be pulled out for service while the appliance remains connected.
Note 2
F
G
2 Cabinet/countertop depth is at discretion of customer but cabinet face MUST NOT protrude further than rear of front panel, see product dimensions.3 Consult local code for exact location requirements.
1 Vertical to combustible surface from range grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances.
Non-combustible surface along
back wallrecommended
10” (254 mm) Min.to combustible sidewalls above the range(both sides)
30” (762 mm)Min.1
36 1/2” (927 mm)
Max.
13” (330 mm)Max.4
18” (457 mm)Min.1, 4
Suggested location of utilities
3
4 Not applicable for cabinets more than a horizontal distance of 10” (254 mm) from the edge of the range.
G
10" (254 mm) Min.to combustible sidewalls above the range(both sides)
non-combustible
Minumum Countertop Height:30 1/4” (768 mm) Maximum Countertop Height:36 1/2” (927 mm)
rear wall recommended
Backsplash
3/8" (10 mm)Min. flat countertop
overhang
H
2 13/16"(71.4 mm)
3
CUTOUT wITH OPTIONAL Erv rAISED vENT (TOP vIEw)
APPROVED RAISED VENT MODELS
Raised Vent Model For Use With Range Model
ERV36-ER ER36D
ERV48-ER ER48D
Stiffener Cabinet face**
Countertop*
* IMPORTANT: See “CUTOUT WITH OPTIONAL ERV RAISED VENT” for countertop cutout dimensions.
** IMPORTANT: Cabinet face must not stick out further thanback of control panel.
Back ofcontrolpanel
ERV36-ER orERV48-ERraised vent
ER36D or ER48D Range
3/8” Min. (10 mm)space behindraised vent chassis to clearstiffener
3/8” Min. (10 mm)flat countertop overhangrequired behind cutout
Countertop height:30 1/4" (768 mm) Min.36 1/2” (927 mm) Max.
rAISED vENT INSTALLATION SIDE vIEw
Cutout tolerances: +1/16” (+1.6 mm), -0 unless otherwise stated
Document # PG05-004 Revised 04/21/10 Page 2/2
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.12
30 Inch wide millennia® Electric range
mrES30
PrODUCT DImENSIONS - ISO vIEw
35”(88.9 cm)
5/16” - 1 13/16”8 mm - 46 mm)
Removable (factory installed)3” (7.6 cm) side panels
Optional full size side panels(ARSL30S, ARSR30S)
60” (152.4 cm) long240 Vac 4 wireconduit location
Door opened
Range top23 1/2"
(59.7 cm)
25 5/16"(64.3 cm)Rear of control
Panel/oven door
Max. depth to oven door handle with door closed
30"(76.2 cm)
45 1/4"(114.9 cm)
PrODUCT DImENSIONS - TOP vIEw
All tolerances: +1/16”, -0, (+1.6mm, -0) unless otherwise stated
The optional full size side panels are for installation where the side of the range will not be covered by the cabinet. For the right side panel, order Dacor part number ARSR30S. Order part number ARSL30S for the left side.
The above specifications are for reference only. See the product data label for exact specifications.
For self-rimming cutout dimensions, see the following page.
Document # PG05-005 Revised 11/24/10 Page 1/2
Dedicated Circuit Required Total Connected Load240 Vac, 60 Hz., 4-wire*, 50 Amp. 12.5 kW (48.2 Amp.)
ELECTrICAL rEqUIrEmENTS
NOTES:1. Electrical is located in the right rear corner of the unit.2. Range is supplied with a 60” (1524 cm) long 240V 4-wire conduit.
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
2
36" (91.4 cm) recommended30" (76.2 cm) min.
30 1/16"(76.4 cm)
25"(63.5 cm)
Hood
30" (76.2 cm)min.* 10" (25.4 cm)
min. to combustiblesside wall (both sides)
Vertical to combustible surface from cooktop surface
Non-combustible rear wall recommended
Electrical locations** 1) Recommeded 2) Alternate
Consult local code for exact location requirements***
1
Top of finishedcounter
18" (45.7 cm)min.*
13" (33.0 cm)max.
14”H (35.6 cm) X 10”W (25.4 cm)
FrEESTANDING CUTOUT DImENSIONS
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.13
mrES30
1/4" (6 mm)min. flat ledge
28 11/16" (72.9 cm) 11/16"(1.7 cm)29 5/8" (75.2 cm)
Rear wall
25"(63.5 cm)
Adjust for backsplashthickness13/16" to 4 1/4" (2.1 - 10.8 cm)
Backsplash
Verticalnon-combustiblesurface rear wall
27 13/16"(70.6 cm)
29 1/4" (74.3 cm)13/32" (1.0 cm)30 1/16" (76.4 cm)
Countertop overhangs cabinet10" (25.4 cm) min.to combustible sidewalls above the range(both sides)
27 7/8" (70.8 cm)
Adjust for backsplashover 3/4" thickfrom 13/16" to 3 13/16" (2.1 - 9.7 cm)
Backsplashthicker than3/4" (1.9 cm)
1/4" (6 mm)min. flat ledge
Vertical non-combustible surface rear wall
2 13/16"(7.1 cm)
TOP vIEw - SLIDE-IN, SELF-rImmING INSTALLATION USING 3” SIDE PANELS wITH BACkGUArD rEmOvED
TOP vIEw - DOwNDrAFT Erv30 wITH SLIDE-IN, SELF-rImmING INSTALLATION USING 3” SIDE PANELSwITH BACkGUArD rEmOvED
All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
Document # PG05-005 Revised 11/24/10 Page 2/2
30 Inch wide millennia® Electric range
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.14
Ranges equipped for installation in Canada:
■ Ranges equipped for use in Canada come pre-wired with a 4-wire, 66 inch (168 cm) long, appliance cord and NEMA 14-50P plug.
■ Do not modify the factory wiring. The plug is designed to plug directly into a NEMA 14-50R electrical receptacle installed by a licensed electrician.
All other models:The conduit or appliance cord installed needs to be long enough to allow the range to be pulled out from the wall for service, while remaining connected. See next page for further details.The wiring to the range must:
◊ Include a strain relief.
◊ Be terminated by tinned leads, closed loop terminals or open ended spade lugs with upturned ends.
Where local code permits, a 3 or 4 wire appliance cord may be used. It must:
◊ Be UL listed type SRD or SRDT.
◊ Be equipped with a NEMA 14-50P 4-wire plug or, where local code permits, a NEMA 10-50P 3-wire plug.
Distinctive range
Dr30D
Optional Backguard and Island Trim Part Numbers
Description Part Number
Island trim kit (no backguard) ADTK30
6 inch trim kit ADB3006
9 inch trim kit ADB3009
Electrical Specifications
Circuit Required Total Connected Load
240 Vac, 60 Hz., 30 Amp.* 5.7 kW (23.8 Amp.)
The ratings above are for reference only - refer to the range's product data label for exact specifications.
NOTE: This range is NOT designed for self-rimming installation or installation with a raised vent.
1 1/8” (2.9 cm)
Rear of front panel/oven door
Front of knobs
Front of open door
Front panel
3” (7.6 cm)Backguard*
6” (15.2 cm)Backguard**
** Optional Standard*
37 7/8”(96.2 cm)
to
35 3/4”(90.8 cm)
Width at front panel: 29 7/8” (75.9 cm)
Finished side panel
9” (22.9 cm)Backguard**
1 1/8” (2.9 mm) to cookingsurface (top of grates) fromtop of trim
26 1/2” (67.3 cm)28 1/2” (72.4 cm)
24 3/8” (61.9 cm)
46 3/8” (117.8 cm)
All tolerances: ±1/16” (±1.6 mm) unless otherwise stated.
WARNING• Observe all governing codes and ordinances during
planning and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
Document # PG05 - 006 Revised 1/26/10 Page 1/2
* Two 120 Vac hot (L1 and L2), one neutral, one ground
The regulator inlet accommodates a 3/4” gas line. The range ships with a 1/2” to 3/4” adapter connected to the regulator.
Gas - Electrical Access Dimensions
A B C D
4 3/4”(12.1 cm)
22 1/8”(56.2 cm)
8 3/4”(22.2 cm)
13 3/4”(34.9 cm)
B
Gas inlet
AC
7/8” (2.2 cm) dia. electrical connection hole in bottom*
D
Range electrical access, cover removed
GAS AND ELECTrICAL DImENSIONS
PrODUCT DImENSIONS
Gas Supply Pressure Requirements*
Gas Type Manifold Pressure Minimum Gas Supply Pressure
Natural gas 5” water column 6” water column
LP 10” water column 11” water column
* Maximum input gas supply pressure for all models is 1/2 p.s.i.
7/8" to 1 1/8" dia. access hole
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 5.15
Distinctive range
Dr30D
Note 2
E
F
2 Cabinet/countertop depth is at discretion of customer but cabinet face MUST NOT protrude further than rear of front panel, see product dimensions.3 Consult local code for exact location requirements.
1 Vertical to combustible surface from range grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances.
Non-combustible surface along
back wallrecommended
10” (25.4 cm) Min.to combustible sidewalls above the range(both sides)
30” (76.2 cm)Min.1
37 7/8(96.2 cm)
Max.
13” (33.0 cm)Max.4
18” (45.7 cm)Min.1, 4
Suggested location of utilities
3
4 Not applicable for cabinets more than a horizontal distance of 10” (25.4 cm) from the edge of the range.
Cutout DimensionsE F
36” (91.4 cm)*30” (76.2 cm)** 30 1/16” (916mm)
* Recommended ** Minimum
Gas and Electrical Service ■ The shaded area shown below denotes the location of the gas inlet
and the electrical junction box/receptacle. This is the recommended location. For replacement purposes, the location of the existing utilities may be utilized provided they do not interfere with the sides or rear of the range. Check local building codes for permissible gas valve locations.
■ An external manual shut-off valve must be installed between the gas inlet and the range for the purpose of turning on or shutting off gas to the appliance.
The installation must allow for the following: ■ Access to the gas shut-off valve when the unit is installed.
■ Access to the remote circuit breaker panel/fuse box when the range is in place.
■ The gas supply piping, gas shut-off valve and the electrical junction box or receptacle must be located so they do not interfere with the range when it is installed.
■ The junction box and gas shut off valve must be located so that the range can be pulled out for service while the appliance remains connected.
Cabinet Layout ■ Carefully check the location where the range is to be installed. For
best performance, the range should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets.
■ To reduce the risk of personal injury and to reduce accumulated smoke in the room, Dacor strongly recommends installing a range hood. A range hood should project horizontally a minimum of five (5) inches beyond the face of the cabinets.
■ All maximum and minimum dimensions and clearances shown in the diagram below must be maintained for safe operation.
■ The range may be installed flush to the rear wall. A non-combustible rear wall is not mandatory, but Dacor highly recommends installing a non-combustible material from the countertop level up to the vent hood or installation of a backguard.
■ Any openings in the wall behind the appliance or in the floor underneath it must be sealed.
rEqUIrED CABINET DImENSIONS
Cabinet tolerances: -1/16”, (+1.6mm) -0
Document # PG05 - 006 Revised 1/26/10 Page 2/2
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 6.1
Duct Planning Guide
DUCT PLANNING GUIDEDocument # PG06 - 001 Revised 10/21/09 Page 1/1
WARNING• All blowers, hoods and raised vents must be installed in
accordance with the accompanying installation instructions.• Observe all governing codes and ordinances during planning
and installation. Use only duct work deemed acceptable by state, municipal and local codes and by the installation instructions. Contact your local building department for further information.
• To prevent combustion by-products, smoke or odors from entering the home and to improve efficiency, tape all duct joints securely.
• Hoods and vents may interrupt the proper flow of smoke and combustion gases from furnaces, gas water heaters and fireplaces. To avoid drawing lethal gases into the home, follow the manufacturer’s recommendation for these devices and consult NFPA and ASHRAE recommendations.
• Improper installation may result in a back draft and/or the insufficient venting of smoke and fumes.
• For hoods or raised vents equipped with integral blowers, DO NOT install an additional in-line or external blower to increase the length of the duct run. For hoods or raised vents not equipped with integral blowers, DO NOT install more than one in-line or external blower. Even small differences between blower air flow rates can greatly reduce the air draw.
• To reduce the risk of fire and to properly exhaust air, be sure to duct air outside the house or building. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages.
General Design Requirements◊ All duct work materials (including screws and duct tape) must be
purchased separately by the customer. When planning new duct work, always look for the shortest, most direct route to the outside. Some models can accommodate venting (and/or wiring) through the back.
◊ To prevent a back draft, never decrease the duct size over the run. If existing duct work is smaller than 8 inches in diameter, remove it and replace it with 8" round, 10" inch round or 3 1/4" x 10" duct work. Do not use duct work that is smaller in cross-sectional area than these recommended types. Do not use flexible metal duct.
◊ Do not rely on tape alone to seal duct joints. Fasten all connections with sheet metal screws and tape all joints with certified silver tape or duct tape. Use sheet metal screws as required to support the duct weight.
◊ To prevent back-drafts, a damper at the duct outlet may also be required.
◊ Make sure duct work does not interfere with floor joists or wall studs.
◊ On dual exhaust models, the two 8” exhausts may be merged into one 10” duct using a Dacor transition kit. See the installation instructions for details.
◊ With concrete slab construction, "box-in" the duct work to prevent it from collapsing when the wet concrete is poured. Also allow room for electrical conduit.
Calculating the Maximum Duct Run Length◊ The maximum straight duct length is determined by the type of
hood or raised vent installed and type of duct used. See the hood or raised vent specifications for the maximum duct run for the desired configuration.
◊ To determine the actual length the duct work cannot exceed, subtract all of the equivalent lengths of the elbows and transitions listed below from the maximum straight duct run from the hood/raised vent specifications. After determining that your proposed duct work meets the maximum duct length requirement, proceed with the location planning.
Equivalent LengthsPiece Subtract Piece Subtract
8” 90° elbow 7 feet 10” 90° elbow 5 feet
8” 45° elbow 3 feet 10” 45° elbow 2 feet
3¼” X 10” to round
90° transition25 feet
3¼” X 10” to 8”/10” round
transition4 feet
3 ¼” X 10" 45° elbow 7 feet 3 ¼” X 10"
90° elbow 15 feet
3 ¼” X 10" 90°flatelbow 20 feet
Roof cap * Wall cap with damper *
* The equivalent lengths of roof and wall caps vary with model and configuration. For equivalent length, contact the manufacturer or a qualified HVAC specialist.
Duct Work Design Tips◊ Wherever possible, reduce the number of transitions and turns to as
few sharp angles as possible. Two staggered 45° angles are better than one 90°.
◊ If multiple elbows are used, try to keep a minimum of 24” straight duct between them. Avoid “S” or “back to back” use of adjacent elbows.
◊ Keep turns as far away from the hood or raised vent exhaust as possible, and as much space between bends as possible.
◊ For best performance, use round duct instead of rectangular, especially when elbows are required.
◊ Cross-drafts or air currents caused by adjacent open windows or doors, HVAC outlets, ceiling fans and recessed ceiling lights reduce vent efficiency.
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 7.1
DHw Hoods
DHw SErIES OvErALL DImENSIONS
Chimney
24”
Min
. 30”
- M
ax. 4
2”
30” - 36” - 42” - 48”
15”11 3/4”
5 3/4”
12 1
/2”
16 1
/4” *
24 3
/4”
Blower 600 CFM* (1200 CFM* for units with 2 blowers) with electronic speed control
Blower speeds 4
Lights 12 Vac, 20 Watt halogen
Filters Baffletype,dishwashersafe
Exhaust 8 inch
Finish 430 stainless steel
Total connected load
120 Vac, 60 Hz. (see table at right for current rating)
Circuit requirements
120 Vac, 15 Amp. grounded, dedicated 3-wire circuit (hot, neutral, ground)
* At zero inches static pressure
MODEL NUMBERDHW301 DHW361 DHW421 DHW482
Blowers 1 1 1 2
Lights 2 2 3 4
Filters 1 1 1 2
Maximum current draw 3.4 Amp. 3.4 Amp. 3.6 Amp. 6.8 Amp.
IMPORTANT: The minimum installed distance from the hood to the cooking surface must be no less than 30 inches. The minimum specified distance may be higher for the particular range or cooktop in use. Check the manufacturers specifications for the cooktop or range.
* 18” 1/4 on 48 inch model (DHW482)
GENErAL SPECIFICATIONS
mODEL SPECIFIC SPECIFICATIONS
All tolerances: ±1/16” (±1.6 mm), -0, unless otherwise stated
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
• DO NOT install an additional in-line or external blower to increase the length of the duct run. Even small differences between blower air flow rates can greatly reduce the air draw of the hood.
Document # PG07-001 Revised 06/24/10 Page 1/1
30”, 36”, 42” and 48” wide wall mount Chimney Hoods
Maximum Duct LengthThe maximum straight duct length for the hood is 50 feet. To determine the actual maximum duct run, subtract the equivalent length of each elbow, transition and cap from 50 feet. See the Duct Planning Guide or the installation instructions for more details.
rEAr ExHAUST DIAGrAm
■ Chimney can accommodate up to 10” round duct work
■ Unit can be installed to exhaust through the ceiling or through the rear wall (see diagram below).
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 7.2
36” (91.4 cm) - 42” (106.7 cm)48” (121.9 cm) - 54” 137.2 cm)
30”(76.2 cm)
15 ¾” (40.0 cm)
Chimney
12 9/16” (31.9 cm)
12
½”
(31.
8 cm
)
15
½”
(39.
4 cm
)*
28”
(71.
1 cm
) to
36” (
91.4
cm
)
DHI SErIES OvErALL DImENSIONS
Blower 600 CFM* (1200 CFM* for units with 2 blowers) with electronic speed control
Blower Speeds 4
Lights 12 Vac, 20 Watt halogen
Filters Baffletype,dishwashersafe
Exhaust 8 Inch
Finish 430 stainless steel
Total connected load 120 Vac, 60 Hz (see table at right for current rating)
Circuit requirements
120 Vac, 15 Amp. grounded, dedicated 3-wire circuit (hot, neutral, ground)
* At zero inches static pressure
** IMPORTANT ORDERING INFORMATION: Each model requires that you order a chimney assembly (Part number DHICH) in addition to the hood assembly part number.
36”, 42”, 48” and 54” wide Ceiling mount Island Hoods
DHI Hoods
Model** Blowers Lights Filters Maximum Current Draw
DHI361 1 4 1 3.8 Amp.
DHI421 1 4 1 3.8 Amp.
DHI482 2 4 2 6.8 Amp.
DHI542 2 6 2 7.1 Amp.
GENErAL SPECIFICATIONS
mODEL SPECIFIC SPECIFICATIONS
* 18” 1/4 on models DHI482 and DHI542
Chimney can accommodate up to 10” round duct work
All tolerances: ±1/16” (±1.6 mm), -0, unless otherwise stated
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
• DO NOT install an additional in-line or external blower to increase the length of the duct run. Even small differences between blower air flow rates can greatly reduce the air draw of the hood.
Document # PG07-002 Revised 06/16/10 Page 1/1
Maximum Duct LengthThe maximum straight duct length for the hood is 50 feet. To determine the actual maximum duct run, subtract the equivalent length of each elbow, transition and cap from 50 feet. See the Duct Planning Guide or the installation instructions for more details.
IMPORTANT: The minimum installed distance from the hood to the cooking surface must be no less than 30 inches. The minimum specified distance may be higher for the particular range or cooktop in use. Check the manufacturers specifications for the cooktop or range.
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 7.3
5/16”(3 mm)
30” min.(76.2 cm)
Rear of blowerunit
Cooktopsurface
Glass
30 Inch and 36 Inch wide Glass wall mount range Hoods
PHw
5 3/4”(14.6 cm)
8” dia.203.2 cm)
10 3/4” (27.3 cm) 11 7/8” (30.2 cm)
26 1/8” (66.4 cm)min.*
44” (111.8 cm)max.*
25 3/8” * (64.5 cm)
19 3/4”(50.2 cm)
19 3/4” * (50.2 cm)
30” (76.2 cm) or36” (91.4 cm)**
* Glass thickness of 5/16” (3 mm) not included** Glass width must be specified at time of order. Specify glass part number: PHGXXBK where XX is the width.
OvErALL DImENSIONS
Blower 600 CFM with electronic speed control
Blower Speeds 4
Lights 120 Vac, 50 Watt halogen (1)
Filters Mesh type, dishwasher safe (2)
Exhaust 8 inch
Finish 430 stainless steel with tempered glass hood
Power Required 120 Vac, 60 Hz., 3.5 Amp.
Circuit Required 120 Vac, 60 Hz., 15 Amp. 3-wire (hot, neutral, ground), grounded, dedicated circuit Min.
GENErAL SPECIFICATIONS
Product tolerances: ±1/16” (±1.6 mm), -0, unless otherwise stated
8” (20 cm)CHImNEY mOUNTING
BrACkET
INSTALLATION - SIDE vIEw
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
• The minimum installed distance from the rear of blower unit base to the cooktop surface must be no less than 30” inches (76.2 cm), 26 inches (66.0 cm) for an electric cooktop. The minimum specified distance may be higher for the particular range or cooktop in use. Check the manufacturers specifications for the cooktop or range.
• DO NOT install an additional in-line or external blower to increase the length of the duct run. Even small differences between blower air flow rates can greatly reduce the air draw of the hood.
Document # PG07-003 Revised 01/25/11 Page 1/1
The hood may exhaust through the ceiling on through a rear wall.
ExAmPLE OF rEAr ExHAUST
Maximum Duct LengthThe maximum straight duct length for the hood is 50 feet. To determine the actual maximum duct run, subtract the equivalent length of each elbow, transition and cap from 50 feet. See the Duct Planning Guide or the installation instructions for more details.
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 7.4
30”, 36”, 42”, 48”, 54” wide Hoods
EH, EHr and mH wall mount range Hoods
Overall DimensionsModel A B C
EH/EHR3012 29 7/8” (75.9 cm)
26 7/8” (68.3 cm)
12 3/8” (31.4 cm)
EH/EHR3612 35 7/8” (91.1 cm)
EH/EHR4212 41 7/8” (106.4 cm)
EH/EHR4812 47 7/8” (121.6 cm)
MH3012 29 7/8” (75.9 cm)25 1/2”
(64.8 cm)MH3612 35 7/8” (91.1 cm)
MH4812 47 7/8” (121.6 cm)
EH/EHR3018 29 7/8” (75.9 cm)
26 7/8” (68.3 cm)
18” (45.7 cm)
EH/EHR3618 35 7/8” (91.1 cm)
EH/EHR4218 41 7/8” (106.4 cm)
EH/EHR4818 47 7/8” (121.6 cm)
EH/EHR5418 53 7/8 (136.8 cm)
MH3018 29 7/8” (75.9 cm)25” 1/2
(64.8 cm)MH3618 35 7/8” (91.1 cm)
MH4818 47 7/8” (121.6 cm)
11 7/8” (30.2 cm)
A
B
C
OvErALL DImENSIONS
NOTE: The exhaust duct(s) and electrical wiring can be connected from either the top or the back of the hood.
DImENSIONS OF OPTIONAL AHT10 TrANSITION
32” (81.3 cm)
13 ¾” (34.9 cm)
¾” (1.9 cm)
9” (22.9 cm)
2” (5.1 cm)
Minimum Cabinet Width
Models D
EH3012, EH3018, MH3012, MH3018 30” (76.2 cm)
EH3612, EH3618, MH3612, MH3618 36” (91.5 cm)
EH4212, EH4218 42” (106.7 cm)
EH4812, EH4818, MH4812, MH4818 48” (121.9 cm)
EH5418 54” (137.2 cm)
E
25” Min.* (63.5 cm)
Electrical access
All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
Document # PG07-004 Revised 05/14/10 Page 1/3
* Height above cooking surface. The minimum specified distance may be higher for the particular range or cooktop in use. Check the manufacturers specifications for the cooktop or range.
D
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 7.5
Weight SpecificationsModels Weight
EH3012, MH3012 48 lbs. (22 kg)
EH3018, MH3018, EH3612, MH3612 53 lbs. (24 kg)
EH3618, MH3618 57 lbs. (26 kg)
EH4212 55 lbs. (25 kg)
EH4218 60 lbs. (27 kg)
EH4812, MH4812 70 lbs. (32 kg)
EH4818, MH4818 77 lbs. (35 kg)
EH5418 84 lbs. (38 kg)
All Models
Fan speeds 4
Filters Mesh type, dishwasher safe
Exhaust(s) 8-inch
Total connect load 120 Vac, 60 Hz, 9 Amp. Max. (10.0 Amp. Max. surge)
Lights 120 Vac, 75 W halogen
Circuit requirement 120 Vac, 15 Amp. dedicated, grounded circuit
Model Specific
EH48, EHR48, MH48, EH54 EH42, EHR42
EH30, EHR30, MH30, EH36, EHR36, MH36
Lights 3 2 2
Filters 4 3 2
Exhaust outputs 2 1 1
Fan* rating 1200 CFM 600 CFM 600 CFM
* Does not apply to EHR Series
GENErAL SPECIFICATIONS
Weight Specifications
Models WeightEHR3012 39 lbs. (18 kg)
EHR3018, EHR3612 44 lbs. (20 kg)
EHR3618 48 lbs. (22 kg)
EHR4212 46 lbs. (21 kg)
EHR4218 51 lbs. (23 kg)
EHR4812 52 lbs. (24 kg)
EHR4818 59 lbs. (27 kg)
EHR5418 66.4 lbs. (30 kg)
Duct Size Maximum Straight Duct Run
8” round 60 feet
10” round 50 feet
3¼” X 10” rectangular 50 feet
IMPORTANT: When planning the installation, you must calculate the actual length the duct work cannot exceed. To calculate actual maximum duct length, use the above specifications in combination with the Duct Planning Guide or see the hood installation instructions.
30”, 36”, 42”, 48”, 54” wide Hoods
EH, EHr and mH wall mount range Hoods
Document # PG07-004 Revised 05/14/10 Page 2/3
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 7.6
NOTE: The exhaust duct(s) and electrical wiring can be connected from either the top or the back of the hood.
All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated.
Models EH48, EHR48, MH48, EH54, EHR54 All other models
* **
BACk DImENSIONS
3” (7.6 cm)
¾” (1.9 cm)
Electrical access holes 7/8” Dia. (5.1 cm)
CL
Bottom of hood
Dual exhaust models* Standard 8” duct connection
Single exhaust models** Standard 8” duct connection
9 7/8” (25.1 cm)
19 ¾” (50.2 cm)
4” (10.2 cm)
E***
Front of hood
Dual exhaust models* Standard 8” duct connection
CL
Electrical access holes 7/8” Dia. (5.1 cm)
1 ½” (3.8 cm)
6 1/8” (15.6 cm)
CL
CL
Single exhaust models** Standard 8” duct connection
3” (7.6 cm)
4” (10.2 cm)
9 7/8” (25.1 cm)
19 ¾” (50.2 cm)
TOP DImENSIONS
***Rear Exhaust PlacementNominal Hood Height E
12” 4 1/2” (11.4 cm)
18” 6 1/8” (15.6 cm)
30”, 36”, 42”, 48”, 54” wide Hoods
EH, EHr and mH wall mount range Hoods
Document # PG07-004 Revised 05/14/10 Page 3/3
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 7.7
IvS1, IvS2, IvSr1, IvSr2
Integrated ventilation System
21 1/4"(54.0 cm)
22 1/2"(57.2 cm)
6” (15.2 cm)
11 1/16"(28.1 cm)
12 1/4"(31.1 cm)
Electricalaccessholes
8" (20,3 cm) round exhaustwith back draft damper
IvS1/IvSr1 OvErALL DImENSIONS
33 1/4"(84.5 cm)34 1/2"
(87.6 cm)
6” (15.2 cm)
11 1/16"(28.1 cm)
12 1/4"(31.1 cm)
8" (20,3 cm) round exhaustswith back draft damper
Electricalaccessholes
IvS2/IvSr2 OvErALL DImENSIONS
21" (53.3 cm)
8" (20.3 cm)
13" (33.0 cm)
10 inch round
2" (5.1 cm)8" Exhaust
CL
CL
IvS1/IvSr1 ExHAUST DImENSIONS - TOP vIEw
8" Exhaust
CL CL CL
CL
6 1/2"(16.5 cm)
6 1/2"(16.5 cm)
IvS2/IvSr2 ExHAUST DImENSIONS - TOP vIEw
ATD10 DImENSIONS - FOr USE wITH IvS2 AND IvSr2 (SOLD SEPArATELY)
Model No. Dedicated CircuitRequired
Maximum Duct Length
Total Connected Load
Blower Configuration Blower Rating Approximate
Shipping WeightIVS1
120 Vac, 60 Hz., 15 Amp. Min.
grounded,dedicated circuit
Maximum 60 equivalent
straight feet
0.2 kW (2 Amp.) Internal 600 CFM Nom. 25 lbs.
IVSR1 0.2 kW (1.5 Amp.)* Remote** SeeREMPspecifications 21 lbs.
IVS2 0.4 kW (3 Amp.) Internal 1200 CFM Nom. 38 lbs.
IVSR2 0.2 kW (1.5 Amp.)* Remote** SeeREMPspecifications 29 lbs.
* Does not include remote blower. ** Remote blower required. Use only Dacor REMP series remote blower *** At zero inches static pressure
All tolerances: ±1/16” (±1.6 mm) unless otherwise stated.
Document # PG07 - 006 Revised 02/24/10 Page 1/1
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
NOTE: The Dacor IHL series integrated hood liner is designed for use with all Dacor IVS series integrated ventilation systems. Together the IVS and IHL series products can be built into a custom hood structure to provide the required ventilation and heat resistant, easy to clean surfaces.
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 7.8
Custom Hood Liners
IHL
IHL SErIES HOOD LINEr DImENSIONS
HEIGHT OF IHL SErIES HOOD LINEr AND IvS SErIES INTEGrATED vENTILATION SYSTEm wHEN ASSEmBLED
vENTILATION SYSTEm COmPATIBILITY
Custom hood
Dacor IVS series integrated ventilation system
Hood liner mounting screw, number required varies with
model, see table
Cap nuts/lock washers for mounting IVS (provided with IHL kit)
21"(53.3 cm)
13 7/16"(34.1 cm)
4"(10.2 cm)
A
Mounting holefor IVS
IHL mounting hole,number and locations
vary with model
CL
10"(25.4 cm)
All tolerances: ±1/16” (±1.6 mm) unless otherwise stated.
Document # PG07-005 Revised 11/30/10 Page 1/1
WARNING• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
IHL Model (A) Width Dimension
Number Mounting Holes/Mounting
Screws Required*IHL30 27” (68.6 cm) 4
IHL36 33” (83.8 cm) 4
IHL42 39” (99.1 cm) 6
IHL48 45” (114.3 cm) 6
IHL54 51” (129.5 cm) 6
IHL Model IVS Model
IHL30 IVS1
IHL36 IVS1
IHL42 IVS2
IHL48 IVS2
IHL54 IVS2
The Dacor IHL series integrated hood liner is used to line the inside of custom built range hoods. It is constructed with non-combustible stainless steel and is designed for use with Dacor IVS series integrated ventilation systems. Together the IVS and IHL series products can be built into a custom hood structure to provide the required ventilation and heat resistant, easy to clean surfaces.
Dacor IHL series hood liner
* #8 mounting screws (not included) are required. Length and type must be determined according to application (mounting material).
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.1
30”, 36”, 46”, 48” wide,Slim raised vent
Erv30, Erv36, Erv48,Prv30, Prv36, Prv46
30 ¼"(768 mm)
to37 ¼"
(946 mm)
10"(254 mm)
30"(762 mm)
18 5/8”(473 mm)
5/16” (8 mm)thick stiffeneracross back
3 3/4"(95 mm)
1"(25 mm)
28" 3 prong grounded
power cord
Vent shownin raisedposition
Product data label
Motorcover
Front of unit
6"(152 mm)
2 9/16"(65 mm)
9/16"(14 mm)
2 1/2"(64 mm)
1 15/16"(49 mm)
B
A
Adjustableanchor legs
2 1/8"(54 mm)
2 3/16"(56 mm)
3/16"(5 mm)
Top cap withvent down
DImENSIONS SIDE vIEw DImENSIONS FrONT vIEw
All tolerances: ±1/16” (±1.6 mm) unless otherwise stated
WARNING• Observe all governing codes and ordinances
during planning and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
2 1/8" (54 mm)
3/8"(10 mm)
2 1/8" (54 mm)
ERV top cap - side view
PRV top cap - side view
7/16"(11 mm)
Model No. A B Circuit Requirement*
ERV/PRV30 30” (762 mm)
27 3/8” (695 mm)
Three prong electri-cal outlet connected to 120 Vac, 60 Hz, 15 Amp. grounded, dedicated, circuit
ERV/PRV36 36” (914 mm)
33 3/8” 848 mm)
PRV46 46” (1168 mm)
43 3/8” (1102 mm)
ERV48 48” (1219 mm)
43 3/8” (1102 mm)
* Includes power supply requirements for external blower
NOTES:1. The maximum installed height must not exceed the
maximum specified countertop height of cooking appliances.
2. Install these raised vents only with approved Dacor appliances. See the planning guide for the particular appliance for proper applications and cutout information.
3. This appliance must be install in conjunction with a single Dacor approved remote or in-line blower. See following pages for approved blowers.
Document # PG08-001 Revised 03/29/10 Page 1/3
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.2
Erv30, Erv36, Erv48,Prv30, Prv36, Prv46
30”, 36”, 46”, 48” wide,Slim raised vent
Duct Work Design Tips ■ Wherever possible, reduce the number of transitions and turns to as
few sharp angles as possible. Two staggered 45° angles are better than one 90°. Keep turns as far away from the hood exhaust as possible, with as much space between each bend as possible.
■ For best performance, use round duct instead of rectangular when possible, especially when elbows are required.
■ If multiple elbows are used, try to keep a minimum of 24” of straight duct between them. Avoid “S” or “back to back” configurations of adjacent elbows.
■ Do not use flexible metal duct.
Calculating the Maximum Duct Run Length ■ Do not use duct work that is smaller in cross-sectional area than the
required duct sizes in the table to the right.
■ For best performance, keep the duct run as short as possible and never exceed the maximums stated at the right.
■ The maximum straight duct length for the raised vent system depends on the model of remote or in-line blower used with the vent system and the number of elbows and transitions used. The Equivalent Number of Feet for each elbow and transition (see table) must be subtracted from the maximum straight length to compensate for wind resistance. To determine the maximum allowable length of the duct work, subtract all of the equivalent lengths of the elbows and transitions from the Blower Maximum Duct Straight Length.
For example, for a raised vent system using 3 1/4” X 10” rectangular duct, two (2) 3 1/4” X 10” 90° elbows, a 3 1/4” X 10” rectangular to 10” round transition, and a REMP16 remote blower:
■ From the Blower Maximum Duct Straight Length table, the maximum length without transitions and elbows is 60 feet.
■ The equivalent length of each 90° elbow is 15 feet.
■ The equivalent length of 45° elbow is 2 feet.
■ The equivalent length of the transition is 4 feet.
■ The total equivalent length of the above components is: 15 feet + 15 feet + 4 feet + 2 feet = 36 feet.
■ The maximum amount of straight duct that can be used with a REMP16 and the above components is: 60 feet - 34 feet = 24 feet.
Equivalent Number of Feet - Duct Elbows and Transitions
45° elbow 8 Inch 3 feet 3 ¼” X 10
45° elbow 7 feet
45° elbow10 Inch 2 feet 3 ¼” X 10
90° elbow 15 feet
90° elbow 8 Inch 7 feet 3 ¼” X 10
90°flatelbow 20 feet
90° elbow10 Inch” 5 feet
3 ¼” X 10 to 8” roundtransition
4 feet
90° 3 ¼” X 10 to 8” round
transition25 feet
3 ¼” X 10 to 10” round
transition4 feet
Roof cap * Wall cap *
* The equivalent lengths of roof and wall caps vary with model and configuration. For equivalent length, contact the manufacturer or a qualified HVAC specialist.
Document # PG08-001 Revised 03/29/10 Page 2/3
Raised Vent Model No.
Approved Dacor Blowers*
ERV/PRV30Remote blowers:
REMP3 or REMP16In-line blowers:
ILHSF8 or ILHSF10
ERV/PRV36
PRV46
ERV48
*For detailed information on the remote/in-line blowers, refer to the blower installation instructions.
Duct Size Used
Blower Maximum Duct Straight LengthREMP3 Remote Blower REMP16 Remote Blower ILHSF8 In-line Blower ILHSF10 In-line Blower
8 Inch 50 feet (15.2 meters) 60 feet (18.3 meters) 50 feet (15.2 meters) 60 feet (18.3 meters)
10 Inch 40 feet (12.2 meters) 70 feet (21.3 meters) 40 feet (12.2 meters) 70 feet (21.3 meters)
3 ¼” X 10” 40 feet (12.2 meters) 60 feet (18.3 meters) 40 feet (12.2 meters) 60 feet (18.3 meters)
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.3
30”, 36”, 46”, 48” wide,Slim raised vent
Erv30, Erv36, Erv48,Prv30, Prv36, Prv46
ExHAUST OUTLET LOCATION OPTIONS
FrONT vIEwSIDE vIEw
All tolerances: ±1/16” (±1.6 mm) unless otherwise stated
NOTE: See the appliance planning guide page for cutout dimensions
Rear Exhaust Knock Out (3 1/4” X 10”)
3”
Vertical center line of rear exhaust knock out lines up with vertical center line of chassis
On 46” and 48” wide models, the vertical center line of bottom knock- out lines up with vertical center line of chassis
On 30” and 36” wide models, the vertical center line of bottom knock- out is offset 3”
Side Exhaust Knock Outs (1 5/8” X 16”)
Bottom Exhaust Knock Out (1 5/8” X 16”)
Motorcover
Front of unit
26" (
660
mm
)
6 1/4"(159 mm)
1 1/8"(29 mm)
CL
CL
CLADT2 TrANSITION (INCLUDED)
wIrING/CONDUIT CONNECTIONS FOr rEmOTE/IN-LINE BLOwEr
3 1/4” X 10” to duct work
2” X 16”, connects to side or bottom exhaust
on raised vent
1"(25 mm)
5"(127 mm)
Blower wiring access hole in bottom
Front of unit
Blower wiring access hole in
side
Document # PG08-001 Revised 03/29/10 Page 3/3
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.4
36” and 48” wideSlim raised vent for Epicure® range
Erv36-Er, Erv48-Er
Model Number A B
ERV36-ER 36” (914 mm) 33 3/8” (848 mm)
ERV48-ER 48” (1219 mm) 43 3/8” (1102 mm)
30 ¼"(768 mm)
to37 ¼"
(946 mm)
10"(254 mm)
30"(762 mm)
18 5/8”(473 mm)
5/16” (8 mm)thick stiffeneracross back
3 3/4"(95 mm)
1"(25 mm)
28" 3 prong grounded
power cord
Vent shownin raisedposition
Product data label
Motorcover
Front of unit
6"(152 mm)
2 9/16"(65 mm)
2 1/2"(64 mm)
1 15/16"(49 mm)
B
A
Adjustableanchor legs
2 13/16"(71 mm)
1/4"(6 mm)
Top cap withvent down
Product Dimensions
All tolerances: +/- 1/16” (+/- 1.6 mm) unless otherwise stated
Document # PG08-002 Revised 03/29/10 Page 1/3
WARNING• Observe all governing codes and ordinances
during planning and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
Circuit Requirement (all models)* Approved Dacor Blowers (all models)**
Three prong electrical outlet con-nected to 120 Vac, 60 Hz, 15 Amp.
grounded, dedicated, circuit
Remote blowers: REMP3 or REMP16
In-line blowers: ILHSF8 or ILHSF10
* Includes power supply requirements for external blower.**For detailed information on the remote/in-line blowers, refer to the blower installation instructions.
NOTES:1. Install these raised vents only with approved Dacor
appliances. See the planning guide for the particular appliance for proper applications and cutout information.
2. This appliance must be install in conjunction with a single Dacor approved remote or in-line blower. See following pages for approved blowers.
NOTE: See the appliance planning guide page for cutout dimensions
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.5
Erv36-Er, Erv48-ErDocument # PG08-002 Revised 03/29/10 Page 2/3
Duct Work Design Tips ■ Wherever possible, reduce the number of transitions and turns to as
few sharp angles as possible. Two staggered 45° angles are better than one 90°. Keep turns as far away from the hood exhaust as possible, with as much space between each bend as possible.
■ For best performance, use round duct instead of rectangular when possible, especially when elbows are required.
■ If multiple elbows are used, try to keep a minimum of 24” of straight duct between them. Avoid “S” or “back to back” configurations of adjacent elbows.
■ Do not use flexible metal duct.
Calculating the Maximum Duct Run Length ■ Do not use duct work that is smaller in cross-sectional area than the
required duct sizes in the table to the right.
■ For best performance, keep the duct run as short as possible and never exceed the maximums stated at the right.
■ The maximum straight duct length for the raised vent system depends on the model of remote or in-line blower used with the vent system and the number of elbows and transitions used. The Equivalent Number of Feet for each elbow and transition (see table) must be subtracted from the maximum straight length to compensate for wind resistance. To determine the maximum allowable length of the duct work, subtract all of the equivalent lengths of the elbows and transitions from the Blower Maximum Duct Straight Length.
For example, for a raised vent system using 3 1/4” X 10” rectangular duct, two (2) 3 1/4” X 10” 90° elbows, a 3 1/4” X 10” rectangular to 10” round transition, and a REMP16 remote blower:
■ From the Blower Maximum Duct Straight Length table, the maximum length without transitions and elbows is 60 feet.
■ The equivalent length of each 90° elbow is 15 feet.
■ The equivalent length of 45° elbow is 2 feet.
■ The equivalent length of the transition is 4 feet.
■ The total equivalent length of the above components is: 15 feet + 15 feet + 4 feet + 2 feet = 36 feet.
■ The maximum amount of straight duct that can be used with a REMP16 and the above components is: 60 feet - 34 feet = 24 feet.
Equivalent Number of Feet - Duct Elbows and Transitions
45° elbow 8 Inch 3 feet 3 ¼” X 10
45° elbow 7 feet
45° elbow10 Inch 2 feet 3 ¼” X 10
90° elbow 15 feet
90° elbow 8 Inch 7 feet 3 ¼” X 10
90°flatelbow 20 feet
90° elbow10 Inch” 5 feet
3 ¼” X 10 to 8” roundtransition
4 feet
90° 3 ¼” X 10 to 8” round
transition25 feet
3 ¼” X 10 to 10” round
transition4 feet
Roof cap * Wall cap *
* The equivalent lengths of roof and wall caps vary with model and configuration. For equivalent length, contact the manufacturer or a qualified HVAC specialist.
Duct Size Used
Blower Maximum Duct Straight LengthREMP3 Remote Blower REMP16 Remote Blower ILHSF8 In-line Blower ILHSF10 In-line Blower
8 Inch 50 feet (15.2 meters) 60 feet (18.3 meters) 50 feet (15.2 meters) 60 feet (18.3 meters)
10 Inch 40 feet (12.2 meters) 70 feet (21.3 meters) 40 feet (12.2 meters) 70 feet (21.3 meters)
3 ¼” X 10” 40 feet (12.2 meters) 60 feet (18.3 meters) 40 feet (12.2 meters) 60 feet (18.3 meters)
36” and 48” wideSlim raised vent for Epicure® range
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.6
Erv36-Er, Erv48-Er
ExHAUST OUTLET LOCATION OPTIONS
FrONT vIEwSIDE vIEw
All tolerances: ±1/16” (±1.6 mm) unless otherwise stated
ADT2 TrANSITION (INCLUDED)
wIrING/CONDUIT CONNECTIONS FOr rEmOTE/IN-LINE BLOwEr
3 1/4” X 10” to duct work
2” X 16”, connects to side or bottom exhaust
on raised vent
1"(25 mm)
5"(127 mm)
Blower wiring access hole in bottom
Front of unit
Blower wiring access hole in
side
Document # PG08-002 Revised 03/29/10 Page 3/3
Rear Exhaust Knock Out (3 1/4” X 10”)
3”
Vertical center line of rear exhaust knock out lines up with vertical center line of chassis
On 46” and 48” wide models, the vertical center line of bottom knock- out lines up with vertical center line of chassis
On 30” and 36” wide models, the vertical center line of bottom knock- out is offset 3”
Side Exhaust Knock Outs (1 5/8” X 16”)
Bottom Exhaust Knock Out (1 5/8” X 16”)
Motorcover
Front of unit 26" (
660
mm
)
6 1/4"(159 mm)
1 1/8"(29 mm)
CL
CL
CL
36” and 48” wideSlim raised vent for Epicure® range
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.7
rv30, rv36, rv46
26 3/4"(679 mm)
1/2” (13 mm)thick stiffeneracross back
4 5/8" (117 mm)9 7/8” (251 mm)with CABP3blower installed
Vent shownin raisedposition
Product data label
2 5/16"(59 mm)
9/16"(14 mm)
3 1/8"(79 mm)
2"(51 mm)
B
A
Adjustableanchor legs
1 13/16"(46 mm)
1 15/16"(49 mm)
3/16"(5 mm)
Top cap with vent down
7" (178 mm)
7 1/2" (191 mm)
Front View
15/16" (24 mm)
28"(711 mm)
to34"
(864 mm)
ModelNumber
A - Top CapWidth
B - ChassisWidth
RV30 30” (762 mm) 27 3/8” (695 mm)
RV36 36” (914 mm) 33 3/8” (848 mm)
RV46 46” (1168 mm) 43 3/8” (1102 mm)
All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
NOTES:1. Install these raised vents only with approved Dacor
cooktops. See the planning guide for the particular appliance for proper applications and cutout information.
2. This appliance must be install in conjunction with a single Dacor approved cabinet, remote or in-line blower. See following pages for approved blowers. For detailed information on the remote and in-line blowers, refer to the blower’s installation instructions.
Document # PG08-003 Revised 03/29/10 Page 1/7
WARNING• Observe all governing codes and ordinances
during planning and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
30”, 36”, 46” wide,raised vent
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.8
rv30, rv36, rv46
Electrical Specifications
WARNINGThe electric service for the raised vent should be installed only by a licensed electrician.
It is the owner’s responsibility to ensure that the electrical connection of this appliance is performed by a qualified electrician. The electrical installation, including minimum supply wire size and grounding, must be in accordance with the National Electric code ANSI/NFPA 70- 2002* (or latest revision) and local codes and ordinances.*A copy of this standard may be obtained from:National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101
Electrical RequirementsPower must be supplied by a separate, grounded, single phase circuit protected by a properly sized circuit breaker or time delay fuse and rated at 120 Vac, 60 Hz, 15 Amps.
■ The above specifications are for reference only. If the power supply requirements shown above do not agree with those listed on the product data label, use the ratings on the label.
■ The suggested location of the junction box supplying power to the unit is to the bottom right of the unit, providing local codes permit.
■ Install 3 conductor wiring/conduit with minimum current carrying capacity of 8 Amps to supply power to the internal cabinet blower or remote blower from the raised vent when turned on.
■ When installing a remote or in-line blower run the wiring/ conduit parallel to the duct work and connect it to the remote blower and raised vent on the ends. There are two 7/8” access holes in the bottom of the raised vent for connecting the wiring to the blower and connecting the vent to the power supply junction box.
General System LayoutThe vent system consists of the raised vent itself and a single Dacor approved remote blower or internal cabinet blower.
Raised Vent Model No. Approved Blowers Duct Sizes
RV30CABP3, ILHSF8, ILHSF10,
REMP3, REMP16
3 1/4” x 10”, 8” round, 10” round
RV36
RV46
WARNING• Failure to install an approved blower and proper duct work
will result in a back draft and/or the insufficient venting of smoke and fumes.
• To reduce the risk of personal injury caused by reaching over a hot appliance, cabinet storage space located directly above the cooktop should be avoided.
• Follow the instructions and diagrams for minimum safe clearances and installation location in these instructions, the appliance installation instructions and the blower installation instructions. Failure to do so may result in a fire or safety hazard.
■ Install the raised vent, blower and cooktop so that they can be removed if service is required.
■ Refer to the cooktop planning guide for the minimum cutout dimensions specific to the particular raised vent model being installed.
■ The raised vent is equipped with adjustable anchor legs to accommodate various cabinet heights.
■ All contact surfaces between the raised vent and any cabinets or walls must be solid and at right angles.
Cabinet blower
Connection tocabinet blower
Electrical accessholes in bottom
Connection toremote/in-line
blower
Connection tojunction box
Document # PG08-003 Revised 03/29/10 Page 2/7
30”, 36”, 46” wide,raised vent
ELECTrICAL LAYOUT
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.9
General System Layout (continued) ■ The raised vent exhaust may be configured to vent through the
bottom or through one of the sides. Allow room for the exhaust duct coming out of the unit. See Planning the Duct Work for additional details.
■ The maximum allowable duct run must be taken into consideration when determining the layout. See Planning the Duct Work for further details.
■ Access from the front of the cabinet to the underside of the cooktop, the vent system and the electrical and gas supplies for the cooktop and vent must be provided for inspection and service. Any drawers or shelves placed below the cooktop and in front of the vent must be easy to remove for access to the cooktop, vent and utilities.
■ For installation with gas cooktops, a 90-degree elbow must be connected to the cooktop gas inlet (see diagram below) to avoid interference with the raised vent’s front panel.
rv30, rv36, rv46
ExAmPLE OF LAYOUT wITHrEmOTE BLOwEr, rOOF ExHAUST
ExAmPLE OF LAYOUT wITHCABINET BLOwEr, ExHAUST THrOUGH wALL
ExAmPLE OF GAS LINE rOUTING FOr GAS COOkTOPINSTALLATIONS - SIDE vIEw
90° Elbow
Gas line withregulatorattached
Raised Vent withinternal cabinetblower mounted
to front
Optional InternalCabinet Blower
Wall cap
Backsplash
Cooktop
12” (305 mm) Min.
Wal
l
floor
Duct directly through rearwall to wall cap
Internal cabinet blower
3 1/4” x 10”90˚ elbow
REMP16 SeriesRemote Blower
Wall Board
Backsplash
Duct workbetween raisedvent and remote
blower
Raised ventconfigured for
bottom exhaust
Wiring/conduit that supplies power
to remote blowerFloor
Cooktop
3 1/4” X 10”to 10” round
transition and 45°adjustable elbow
Document # PG08-003 Revised 03/29/10 Page 3/7
30”, 36”, 46” wide,raised vent
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.10
rv30, rv36, rv46
ExAmPLE OF LAYOUT wITH IN-LINE BLOwEr, DUCT wOrkUNDEr FLOOr, wALL ExHAUST
ILHSF series in-line blower
3 1/4” X 10” to round transition
Duct work Duct work
Outside wall
Cooktop
Wall cap on outside wall
Raised vent
Raised vent configured for
bottom exhaust
Floor
Wiring/conduit from raised vent to in-line blower
Cabinet back
General System Layout (continued)
Document # PG08-003 Revised 03/29/10 Page 4/7
30”, 36”, 46” wide,raised vent
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.11
You must install one of the Dacor blower models listed below for proper operation. For models REMP3 or REMP16, see the REMP3/16 Remote Blower Installation Instructions. For model CABP3, see the instructions later in this manual. Only one blower shall be installed.
BLOWER RATINGS FOR DACOR BLOWERS APPROVED FOR USE WITH RV SERIES RAISED VENTS
Model Number RatingCABP3 (cabinet) 600 CFM*
ILHSF8 (in-line) 600 CFM**
ILHSF10 (in-line) 1100 CFM**
REMP3 (remote) 600 CFM**
REMP16 (remote) 1000 CFM**
* Nominal rating at zero inches static pressure, see the CABP3 Cabinet Blower Data for actual rating.** Nominal rating at zero inches static pressure. See the blower installation instructions for actual blower rating.
■ The raised vent can be configured to exhaust through the bottom or either side:
► On installations using a remote or in-line blower, the cover plate on the appropriate side or on the bottom is removed to expose the exhaust. Configure the raised vent for bottom exhaust and use an elbow to vent through the rear cabinet wall.
► On installations using the CABP3 blower, the blower assembly is mounted to the front of the raised vent with the exhaust pointing in the desire direction. Point the exhaust down and use an elbow to vent through the rear cabinet wall.
■ When planning new duct work, always look for the shortest, most direct route to the outside. Calculate the maximum duct length (see following pages) to determine if the planned duct route will work with the blower selected.
■ On bottom exhaust installations you may cut a hole in the floor to allow the duct work to pass through.
■ All duct work materials (including screws and duct tape) must be purchased separately by the customer.
■ You can increase the duct size over the duct run if desired. To prevent a back draft, never decrease the duct size over the run.
■ Do not rely on duct tape alone to seal duct joints. Fasten all connections with sheet metal screws and tape all joints with certified silver tape or duct tape.
■ Use sheet metal screws as require to support the duct weights.
■ To prevent back-drafts, a damper at the duct outlet may also be required.
■ Make sure duct work does not interfere with floor joists or wall studs.
■ With concrete slab construction, “box-in” the duct work to prevent it from collapsing when the wet concrete is poured. Also allow room for electrical wiring from the remote blower.
■ Cross-drafts or air currents from adjacent open windows or doors, heating/air conditioning outlets, ceiling fans and recessed ceiling lights reduce vent efficiency.
Duct Work Design Tips ■ Wherever possible, reduce the number of transitions and turns to as
few sharp angles as possible. Two staggered 45° angles are better than one 90°. Keep turns as far away from the hood exhaust as possible, with as much space between each bend as possible.
■ For best performance, use round duct instead of rectangular when possible, especially when elbows are required.
■ If multiple elbows are used, try to keep a minimum of 24” of straight duct between them. Avoid “S” or “back to back” configurations of adjacent elbows.
■ Do not use flexible metal duct.
Planning the Duct Work
WARNING• To reduce the risk of fire and to properly exhaust air, be sure to duct air outside the house or building. Do not vent exhaust air into
spaces within walls or ceilings or into attics, crawl spaces or garages.• Tape all duct joints securely to prevent combustion by-products, smoke or odors from entering the home. Doing so will also improve
system efficiency.• For proper operation this unit must be installed with a remote blower or internal cabinet blower. Use only one of the models
specified.• TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK. • DO NOT install more than one blower. Even small differences between blower air flow rates can greatly reduce the air draw by the
raised vent.
rv30, rv36, rv46Document # PG08-003 Revised 03/29/10 Page 5/7
30”, 36”, 46” wide,raised vent
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.12
rv30, rv36, rv46
FrONT ExHAUST DImENSIONSCABP3 BLOwEr - BOTTOm ExHAUST
ExHAUST LOCATIONS AND DImENSIONSFOr IN-LINE/rEmOTE BLOwEr CONFIGUrATIONS
(ILHSF Or rEmP SErIES BLOwErS)
FrONT ExHAUST DImENSIONSCABP3 BLOwEr - rIGHT ExHAUST
FrONT ExHAUST DImENSIONSCABP3 BLOwEr - LEFT ExHAUST
ExHAUST LOCATIONS AND SIDE DImENSIONSFOr CABP3 INTErNAL CABINET BLOwEr
Side Exhaust Locations (3 1/4” X 10”)
Vertical center line of bottom exhaust lines up with vertical center line of chassis
Internal cabinet blower mounting location
Bottom Exhaust Location (3 1/4” X 10”)
CL
CL
CL1 7/8" *(48 mm)
1 7/8" * (48 mm)
Front View
Bottom View
14 3/8"(365 mm)
*Back of unit lines up with back of cutout
RV
8 3/8" (213 mm)from back of RVcutout to center lineof CABP3 exhaustin any orientation(bottom, or side exahust)
Bottom exhaustconfigutationwith rear or bottomduct routingDUCT
DU
CT
CL
CABP3
Cooktop
Duct connectioncenter line
B
Raised ventcenter lineCountertop
3 1/4 X 10Duct
connection
11 5/8"(295 mm)
Duct connectioncenter line
C
Raised ventcenter lineCountertop
3 1/4 X 10Duct
connection
11 3/4"(298 mm)
25 5/8"(651 mm)
Duct connectioncenter line
A
Raised ventcenter lineCountertop
3 1/4 X 10 Duct connection
Planning the Duct Work (continued)
Model A B CRV30RV36 2” (51 mm) 6” (152 mm) 12” (205 mm)
RV46 5” (127 mm) 9” (229 mm) 9” (229 mm)
Document # PG08-003 Revised 03/29/10 Page 6/7
30”, 36”, 46” wide,raised vent
PLANNINGGUIDE
www.dacor.com Phone: (800) 793-0093 Specifications subject to change without notice.Install all appliances according to accompanying installation instructions. 8.13
Calculating the Maximum Duct Run Length ■ Do not use duct work that is smaller in cross-sectional area than the
required duct sizes in the table to the right.
■ For best performance, keep the duct run as short as possible and never exceed the maximums stated at the right.
■ The maximum straight duct length for the raised vent system depends on the model of remote or in-line blower used with the vent system and the number of elbows and transitions used. The Equivalent Number of Feet for each elbow and transition (see table) must be subtracted from the maximum straight length to compensate for wind resistance. To determine the maximum allowable length of the duct work, subtract all of the equivalent lengths of the elbows and transitions from the Blower Maximum Duct Straight Length.
For example, for a raised vent system using 3 1/4” X 10” rectangular duct, two (2) 3 1/4” X 10” 90° elbows, a 3 1/4” X 10” rectangular to 10” round transition with a REMP16 remote blower:
► From the Maximum Equivalent Straight Length table, the maximum length without transitions and elbows is 60 feet.
► The equivalent length of each 90° elbow is 15 feet. ► The equivalent length of 45° elbow is 2 feet. ► The equivalent length of the transition is 4 feet. ► The total equivalent length of the above components is: 15 feet +
15 feet + 4 feet + 2 feet = 36 feet. ► The maximum amount of straight duct that can be used with a
REMP16 and the above components is: 60 feet - 34 feet = 24 feet.
Equivalent Number of Feet -Duct Elbows and Transitions
45° elbow8 Inch 3 feet 3 ¼” X 10
45° elbow 7 feet
45° elbow10 Inch 2 feet 3 ¼” X 10
90° elbow 15 feet
90° elbow8 Inch 7 feet 3 ¼” X 10
90°flatelbow 20 feet
90° elbow10 Inch 5 feet
3 ¼” X 10to 8” roundtransition
4 feet
90° 3 ¼” X 10to 8” roundtransition
25 feet3 ¼” X 10
to 10” roundtransition
4 feet
Roof cap* **Wall cap with
damper* **
* For installations using the CABP3 internal cabinet blower. ** The equivalent lengths of roof and wall caps vary with model and configuration. For equivalent length, contact the manufacturer or a qualified HVAC specialist.
Blower Maximum Duct Straight Length
Blower Used 8 Inch Duct 10 Inch Duct 3 ¼” X 10”Duct
CABP3 50 feet(15.2 meters)
40 feet(12.2 meters)
40 feet(12.2 meters)
ILHSF8 60 feet(18.3 meters)
50 feet(15.2 meters)
50 feet(15.2 meters)
ILHSF10 70 feet(21.3 meters)
80 feet(24.4 meters)
70 feet(21.3 meters)
REMP3 60 feet(18.3 meters)
50 feet(15.2 meters)
50 feet(15.2 meters)
REMP16 70 feet(21.3 meters)
80 feet(24.4 meters)
70 feet(21.3 meters)
rv30, rv36, rv46Document # PG08-003 Revised 03/29/10 Page 7/7