7/28/2019 830-0026-4P_AL1900iF_OpInsManual
1/38
AmpLink 1900i-F
Operation & Installation Manual
830-0026 Rev. 4P
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
2/38
Limited Warranty
On a standard basis, Superconductor Technologies Inc. (STI) warrants its AmpLink1900i-F to be free from any defect in material and workmanship for a period of one
(1) year from the date of shipment.
STIs sole obligation under this warranty is to repair or replace the AmpLink 1900i-F
or any part thereof, which proves to be defective after inspection by STI. Thewarranty for the repaired or replaced AmpLink 1900i-F is the un-expired warranty
period of the original AmpLink 1900i-F, or ninety (90) days whichever is greater.This warranty does not apply to any AmpLink 1900i-F that has been disassembled,
modified, subjected to unusual electrical or physical stress, misuse, neglect,excessive deterioration or erosion, abuse, accident, unauthorized repair, improper
installation, or use in any way that is contrary to the instructions set forth herein.
STI is not liable for any indirect, incidental, consequential or special damages,
including without limitation, lost profits and cost of procurement of substitutegoods.
This warranty is the full extent of obligation and liability assumed by STI with
respect to its AmpLink 1900i-F. STI neither assumes nor authorizes any otherperson to assume for it any other obligations or liability in connection with the sale,
installation or use of its AmpLink 1900i-F.
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
3/38
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
AmpLink 1900i-F
Operation & InstallationManual830-0026 Rev. 4P
STI
460 Ward Drive
Santa Barbara, California 93111Telephone: 805.690.4500
Fax: 805.967.0342E-mail: [email protected]
Web: www.suptech.com
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
4/38
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Information in this document is subject to change without notice. No part of this documentmay be reproduced or transmitted in any form or by any means, electronic or mechanical,
for any purpose, without the express written permission of Superconductor TechnologiesInc.
2004-2009 Superconductor Technologies Inc (STI). All rights reserved.
AmpLink 1900i-F is a trademark of Superconductor Technologies Inc. (STI). All othermarks are properties of their respective owners.
STI part number: 830-0026 Rev. 4P. Last updated: 1/15/09.
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
5/38
v
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Table of Contents
Preface: About this Manual .................................................................................................. 9Overview ........................................................................................................................ 9General Safety................................................................................................................10
Warnings, Cautions, and Notes...............................................................................10Electrostatic Discharge ..........................................................................................10
How to Contact STI..........................................................................................................10
Chapter 1: AmpLink 1900i-F Overview...............................................................................11Overview .......................................................................................................................11AmpLink 1900i-F Configuration..........................................................................................12
Equipment Configuration .......................................................................................12System Configuration............................................................................................12
Functional Description......................................................................................................12RF Signal Flow .....................................................................................................12Power .................................................................................................................13Alarm .................................................................................................................13
Indicators and Connectors ................................................................................................14Front View...........................................................................................................14Rear View............................................................................................................15
Chapter 2: AmpLink 1900i-F Installation Requirements....................................................17Overview .......................................................................................................................17Installation Requirements.................................................................................................17
Conducting a Site Survey.......................................................................................17Site Requirements ................................................................................................18Mounting Requirements.........................................................................................18Reviewing Equipment Shipped from STI...................................................................19Material Requirements ..........................................................................................19Tool Requirements................................................................................................20Test Equipment Requirements................................................................................20
Chapter 3: Installing the AmpLink 1900i-F......................................................................... 21Overview .......................................................................................................................21Unpacking the AmpLink 1900i-F ........................................................................................21Mounting the AmpLink 1900i-F..........................................................................................22Connecting Wires ............................................................................................................22
Connecting the Safety Ground Wire.........................................................................22Connecting the Power Wire ....................................................................................23Connecting Alarm Relays .......................................................................................23
Performing Power Up .......................................................................................................24Performing Functional Checks............................................................................................25
Alarm Relay Test ..................................................................................................25Test Generator Calibration Data..............................................................................25RF System Test ....................................................................................................26
Wiring for Redundancy.....................................................................................................28Connecting RF Jumper Cables ...........................................................................................28
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
6/38
vi
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Chapter 4: AmpLink 1900i-F Maintenance and Troubleshooting Tips .................................31Overview .......................................................................................................................31Periodic AmpLink 1900i-F Maintenance Checklist..................................................................31Troubleshooting Tips........................................................................................................32Instructions for Return Shipment.......................................................................................34
Appendix A: AmpLink 1900i-F Specifications .....................................................................35
Index ..................................................................................................................................37
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
7/38
vii
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
List of Figures
Figure 1. Typical base station integrated with the AmpLink 1900i-F..............................................11Figure 2. RF signal flow block diagram .....................................................................................12Figure 3. Functional block diagram ..........................................................................................13Figure 4. Front panel indicators and connectors.........................................................................14Figure 5. ANTENNA / BTS connectors.......................................................................................15Figure 6. AmpLink units mounted on an equipment rack shelf......................................................18Figure 7. AmpLink units mounted longitudinally on a cable ladder kit............................................18Figure 8. Voltage polarity for 27 VDC (left) and -48 VDC power (right) .........................................23Figure 9. Alarm relay in normal and fault states ........................................................................24Figure 10. Test generator calibration data setup block diagram....................................................26Figure 11. RF system test connections for receive / transmit paths...............................................26Figure 12. Swept response for receive / transmit paths ..............................................................27Figure 13. Wiring for redundancy ............................................................................................28Figure 14. RF jumper cable connections pre- and post-AmpLink installation...................................29
List of Tables
Table 1. Front Panel Indicators ...............................................................................................14Table 2. Front View Description...............................................................................................14Table 3. Rear View Description................................................................................................15Table 4. Equipment Supplied ..................................................................................................19Table 5. Materials Required ....................................................................................................19Table 6. Tools Required .........................................................................................................20Table 7. Test Equipment Required ...........................................................................................20Table 8. PWR / LNA1 and LNA2 LED Troubleshooting..................................................................31Table A1. AmpLink 1900i-F Specifications.................................................................................35
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
8/38
viii
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
9/38
Preface: About this Manual 9
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Preface: About this Manual
Overview
The AmpLink 1900i-F Operation and Installation manual provides detailed information on
the installation requirements and procedures, testing procedures, and maintenance andtroubleshooting tips for proper AmpLink 1900i-F operation and installation. The following
summary provides information about the chapters and appendix.
Chapter Title Description
Preface About this Manual Provides general information about the manual.
1 AmpLink 1900i-FOverview
Describes the role of the AmpLink 1900i-F in atypical wireless base station system. Providesinformation on AmpLink 1900i-F equipment
configurations and functional descriptions.
2 AmpLink 1900i-FInstallation Requirements
Lists the tools, materials, and test equipmentrequired for proper AmpLink 1900i-Finstallation.
3 Installing the AmpLink1900i-F
Provides the following information for installingthe AmpLink 1900i-F: mounting the unit,connecting the safety ground, power, andalarm wires, performing power up, performingfunctional checks, and connecting RF jumpercables.
4 AmpLink 1900i-FMaintenance andTroubleshooting Tips
Provides information about inspecting theAmpLink 1900i-F on a periodic basis and basictroubleshooting tips for problems that may
occur during installation or operation. Thischapter concludes with instructions forreturning the AmpLink 1900i-F in an event of afailure.
Appendix A AmpLink 1900i-FSpecifications
Provides information on power requirements,physical dimensions, and environmentalspecifications.
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
10/38
Preface: About this Manual 10
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
General Safety
Warnings, Cautions, and Notes
Warnings, cautions, and notes are used throughout the manual. Review the significance of
each:
A warning denotes a hazard to personnel. A warning calls attention to aprocedure, which if not correctly performed or adhered to, could result in injuryto personnel.
A caution denotes a hazard to equipment. A caution calls attention to aprocedure, which if not correctly performed or adhered to, could result indamage to the equipment
A note calls attention to a procedure for informational purposes only.
Electrostatic Discharge
The AmpLink 1900i-F contains components that are subject to damage from electrostaticdischarge (ESD). Ensure that you adhere to all appropriate ESD precautions. The following
caution appears throughout the manual during procedures in which the AmpLink 1900i-F
may be subject to damage by ESD.
The AmpLink unit contains components that are subject to damage fromelectrostatic discharge (ESD). Take precautionary measures when handlingAmpLink components.
How to Contact STI
STI Technical Support
1.800.727.3648
STI Customer Service1.888.800.5314
For your convenience, the STI Technical Support number is located at thebottom of each page throughout the manual.
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
11/38
Chapter 1: AmpLink 1900i-F Overview 11
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Chapter 1: AmpLink 1900i-F Overview
Overview
The AmpLink 1900i-F (AmpLink) is a Low Noise Amplifier (LNA) with a dual duplexer that
connects in-line (cascade) with the existing base station equipment. The superiorperformance of the AmpLink unit enables wireless service providers to enhance customer
satisfaction and increase subscriber base by improving the quality of voice and dataconnections within networks.
Figure 1 shows a typical wireless telecommunications base station integrated with theAmpLink unit.
Figure 1. Typical base station integrated with the AmpLink 1900i-F
Some benefits of integrating the AmpLink unit in a wireless telecommunications networkinclude:
Improved receiver noise figure Designed for ease of use
Low power consumption Maintenance-free operation
Convenient base station installation
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
12/38
Chapter 1: AmpLink 1900i-F Overview 12
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
AmpLink 1900i-F Configuration
Equipment Configuration
The AmpLink unit is available for use in the United States Personal Communication Service
(PCS) wireless frequencies. Available in a 2-channel RF receiver configuration, the AmpLink
unit supports either a site with omni-directional antennas or a single sector of a sectoredbase station. A sectored base station requires three AmpLink units.
System Configuration
The AmpLink unit connects in-line (cascade) with existing base station equipment. Figure 2
shows the AmpLink unit installed in a PCS base station sector. As shown, the antenna feedcable connects directly to the antenna port of the AmpLink unit to provide a clear, low noise
signal to the base station receiver.
Figure 2. RF signal flow block diagram
Functional Description
See Figure 3 on page 13 for a functional block diagram of the AmpLink unit.
RF Signal Flow
Do not apply DC voltage to any RF port.
RF signals to / from the antenna connect to the AmpLink connectors labeled ANTENNA CH1and CH2. The dual-duplexers split transmit / receive signals into their respective paths as
shown in Figure 3. After the receive signals leave the duplexers, they route to a sensitiveLNA, and then recombine with the transmit path for connection to the base station
receivers.
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
13/38
Chapter 1: AmpLink 1900i-F Overview 13
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Power
Base station input power (27 VDC or -48 VDC) connects to the POWER terminal block
connections located on the front panel of the AmpLink unit. The input power routes throughtwo 3A fuses to the power and alarm board. The input power requirement is 22 VDC to
60 VDC, suitable for connection to either 27 VDC power or -48 VDC power.
Alarm
The front panel of the AmpLink unit provides a terminal block for alarm connections. From
the AmpLink unit, the multi-conductor alarm wire routes to the base station alarm system,allowing for remote alarm monitoring.
The power and alarm board monitors the supply current to each LNA. If the current is too
low (open circuit) or too high (short circuit) the self-test logic drives the alarm relay to thefault position.
Figure 3. Functional block diagram
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
14/38
Chapter 1: AmpLink 1900i-F Overview 14
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Indicators and Connectors
Front View
The AmpLink unit provides three indicators (LEDs), power and alarm terminal block
connections, fuse holders, and a ground lug as described in Tables 1 and 2.
Figure 4. Front panel indicators and connectors
Table 1. Front Panel Indicators
Item No. Item Description
OFF: No fault in the AmpLink unit (CH1).1 LNA1 LED
RED: Fault in the AmpLink unit (CH1).
OFF: No fault in the AmpLink unit (CH2).2 LNA2 LED
RED: Fault in the AmpLink unit (CH2).
OFF: No power applied to the AmpLink unit.3 PWRLED
GREEN: Power applied to the AmpLink unit.
Table 2. Front View Description
Item No. Item Description
4 ALARM NC, C, and NO(terminal block)
Provides connection from the alarm relay to the base station alarmsystem.
5 VDC IN + and (terminalblock)
Provides input power connection for 27 VDC or -48 VDC.
6 FUSE VDC + and VDC - 27 VDC or -48 VDC input power provides 3A input power protection.
7 GND Chassis ground lug.
1
2
3
6
7
5
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
15/38
Chapter 1: AmpLink 1900i-F Overview 15
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Rear View
The AmpLink unit accommodates up to two RF paths, providing connections to the Antenna
and BTS. For a sectored site, three AmpLink units are required. 7/16 DIN-female typeconnectors are used on the AmpLink unit.
Figure 5. ANTENNA / BTS connectors
Table 3. Rear View Description
Item No. Item Description
1 ANTENNA CH1 / CH2 7/16 DIN-type connector that receives RF signals from theantenna for each AmpLink receive path and passes Txsignals from the base station.
2 BTS CH 1 / CH2 7/16 DIN-type connector that receives RF signals from eachAmpLink receive path output to the base station front-endinput and passes Tx signals from the base station.
Do not apply DC voltage to any RF port.
1
2
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
16/38
Chapter 1: AmpLink 1900i-F Overview 16
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
17/38
Chapter 2: AmpLink 1900i-F Installation Requirements 17
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Chapter 2: AmpLink 1900i-F
Installation Requirements
Overview
Proper AmpLink installation requires equipment, tools, materials, and adequate siteconditions. Conducting a site survey will determine the necessary requirements to prepare
the site for AmpLink installation. Contact STI Technical Support for any questions regardingthe installation requirements.
Prior to installing the AmpLink unit, review the following installation tasks andrequirements:
Conducting a site survey
Reviewing site requirements Reviewing mounting requirements
Reviewing equipment shipped from STI
Assembling tools and materials required for installation
Tools, materials, and test equipment are not supplied with the AmpLink unit.The following sections guide you in preparing the items you need to install theAmpLink unit. If you have questions about the installation requirements, contactSTI Technical Support.
Installation Requirements
Conducting a Site Survey
Conducting a site survey will determine the site requirements for proper AmpLink
installation. For more information or further assistance, contact STI Technical Support.Consider the following as you complete a site survey:
Base station configuration
Are physical or software adjustments required to the base station? If softwareadjustments are required, what settings are appropriate to optimize the base
station?
Condition of the base station, antennas, and interconnectionsInspect the current state of the site: Clear any alarms at the site, sweep antenna
paths, and check interconnections for wear. Mounting location for new equipment
For optimum performance, select a mounting location that provides the shortestconnection between the antenna and the AmpLink unit. The chosen location will
determine how you mount the AmpLink unit.
Mounting kit requirementsA mounting kit is required to properly mount the AmpLink unit: equipment rack
shelf or cable ladder mount. STI offers both options to mount between one to threeAmpLink units. Contact STI Customer Service for pricing and availability.
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
18/38
Chapter 2: AmpLink 1900i-F Installation Requirements 18
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
RF jumper cable and wiring requirements
The AmpLink unit requires RF jumper cables and wiring (safety ground, power, andalarm). STI offers installation kits for your convenience. Contact STI Customer
Service for pricing and availability. Installing AmpLink equipment
From preparation to cutover, the installation typically requires four hours. Completethe installation anytime during the day which includes rerouting the RF jumper
cables to / from the AmpLink unit. This process requires a technician capable ofturning the base station transmitter off and then back on and reinitializing service.
Complete cutover during maintenance hours.
Site Requirements
Review the following site requirements for proper AmpLink installation:
Base stationSheltered enclosure with temperature and humidity control. Maintain the enclosure
between 0C and 50C with conditioned air, and 0% to 90% for relative humidity(non-condensing).
Mounting locationSelect a mounting location that provides space to access the RF jumper cables in the
rear panel of the AmpLink unit.
Power source27 VDC (22 VDC to 30 VDC) or -48 VDC (-42 VDC to -60 VDC) power source
provided through a power distribution circuit breaker of no more than 3A (3A to 5A)capability.
Alarm relay monitoringSet up remote alarm monitoring connections for the AmpLink unit.
Mounting Requirements
A mounting kit is required to properly mount the AmpLink unit. STI offers two mounting
options:
Equipment rack shelf(part number 018-0216):The two-piece equipment rack shelf supports up to three
AmpLink units in a 19 equipment rack. A 23 equipment
rack shelf is also available (part numberMK-AL1900iF-23ERS). Contact STI Customer Service for
pricing and availability.
Figure 6. AmpLink unitsmounted on an
equipment rack shelf
Cable ladder kit (part number 018-0217):
If equipment rack space is limited, STI offers a cable ladderkit to mount up to three AmpLink units longitudinally or
transversely below the cable ladder. A second, low cost,cable ladder kit is also available to mount the AmpLink units
longitudinally only (part number 018-0217-002). Contact STI
Customer Service for pricing and availability. Figure 7. AmpLink unitsmounted longitudinally
on a cable ladder kit
Contact STI Technical Support for more information about proper mounting options.
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
19/38
Chapter 2: AmpLink 1900i-F Installation Requirements 19
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Reviewing Equipment Shipped from STI
Each AmpLink unit contains the items as described in Table 4. Contact STI Customer Service
if items are missing from the table.
Table 4. Equipment Supplied
Item No. Item Part No. Qty Notes1 AmpLink 1900i-F 1900ALFULL2-ID 1 each AmpLink 1900i-F as ordered.
2 Labels 185-0056-003185-0056-004185-0056-005
1 each Labels provided to mark each AmpLinkunit as Alpha, Beta, and Gamma.
3 AmpLink 1900i-F QuickStart Installation Guide
830-0026-02 1 each Provides a quick overview to properlyinstall the AmpLink 1900i-F
4 STI CD 831-0018 1 each Contains the AmpLink 1900i-F Operationand Installation Manual.
Material Requirements
Review the following materials required for AmpLink installation as described in Table 5.
Table 5. Materials Required
Item No. Item Qty Notes
1 Antenna RF jumper cable,flexible, low loss(1/2 minimum)
1 perantennapath, lengthas required
*7/16 DIN connectors, male to male. This cablemust be long enough to connect between theexisting antenna feed coaxial connector and theAmpLink ANTENNA port. (Rerouting the existingfeed jumper cable is recommended for this cable.).
2 BTS RF jumper cable, flexible,low loss (1/2 minimum)
1 per BTSreceivepath, lengthas required
*7/16 DIN connectors, male to male. This cablemust be long enough to connect between theexisting input connector of the base station receiverand the AmpLink BTS port.
3 Wire, power (16 AWG) Length asrequired
Red and black wire preferred for color-coding + and power.
4 Wire, alarm (24 AWG) Length asrequired
If desired, for connecting the AmpLink alarm relayoutputs to the base station system alarm controlunit.
5 Wire, safety ground (6 AWG) Length asrequired
For connecting the AmpLink chassis ground to thebase station ground.
6 Circuit breaker, 5A 1 per unit Used to install the AmpLink unit and performfunctional checks. (Use no more than a 5A circuitbreaker for DC power source.)
7 Nylon wire ties As required For dressing RF jumper cables after integration.
8 Tape / labels As required For labeling RF jumper cables per sector.
*Assumes BTS port and antenna feed cable terminations are 7/16 DIN-femaleconnectors.
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
20/38
Chapter 2: AmpLink 1900i-F Installation Requirements 20
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Tool Requirements
Review the following tools required for AmpLink installation as described in Table 6.
Table 6. Tools Required
Item No. Item Notes
1 Screwdriver, 1/8 flat blade For power and alarm connections, and removing fuses.2 Wrench, 7/16 For loosening / tightening ground lug.
3 Allen wrench, 3/16 For tightening ground wire to ground lug.
6 Torque wrench For torquing RF connectors with a setting of 221+4 in-lbs.
7 Wire stripper For preparing power, alarm, and safety ground wire for properconnection.
8 Wire cutter (diagonal cutter) For preparing power, alarm, and safety ground wire for properinstallation. Also used for nylon wire tie removal.
Test Equipment Requirements
Review the following test equipment required to perform functional checks to the AmpLink
unit as described in Table 7.
Table 7. Test Equipment Required
Item No. Item Notes
1 Digital Multimeter (DMM) orequivalent
Checks alarm relays and input power.
2 RF Signal Generator Generates a continuous wave (CW) carrier for the following: Rx path: 1850 MHz to 1910 MHz
Output level adjusted to -50+1 dBm Tx path: 1930 MHz to 1990 MHz
Output level adjusted to -50+1 dBm
3 Spectrum Analyzer Receives and displays CW carrier at 1850 MHz (Rx path) and1990 MHz (Tx path) across levels -55 dBm to -35 dBm.Measure received power level accurately (+1 dB).
4 Test cables DIN-male connectors required for AmpLink connections.
5 Connector adapter, 7/16 DIN-femaleto 7/16 DIN-male (7/16 DIN barrel) Replaces the AmpLink unit for test signal level calibration.
6 Connector adapter, 7/16 DIN-maleto N-type female*
Requires two adapters and connects the AmpLink unit to theRF Signal Generator / Spectrum Analyzer.
*This connector adapter (Table 7, Item 6) assumes that the RF SignalGenerator and the Spectrum Analyzer use the DIN-female connector and testcables are DIN-male to N-male.
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
21/38
Chapter 3: Installing the AmpLink 1900i-F 21
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Chapter 3: Installing the AmpLink 1900i-F
Overview
Qualified technicians should install the AmpLink unit. Contact STI TechnicalSupport for assistance.
The information described in this chapter can be considered installationguidelines. Technicians should adhere to all local building and electrical codesand permit requirements.
Proper AmpLink installation consists of the following tasks:
Unpacking the AmpLink unit
Mounting the AmpLink unit
Connecting the safety ground, power, and alarm wires Performing power up
Performing functional checks
Connecting RF jumper cables
This chapter describes a generic installation procedure. BTS-specific application notes are
available. Contact STI Technical Support for more information.
See Tables 4-7 for reference to the items required in each section.
Unpacking the AmpLink 1900i-F
The unboxed AmpLink unit weighs 41 lbs. To prevent injury to personnel anddamage to equipment, it is recommended that two people are available to movethe AmpLink unit.
1 Inspect the shipping container for signs of damage. Report any damage to STI
Customer Service.
2 Remove loose packing materials on top of the AmpLink unit. Set aside the packetcontainingthe CD.
3 With the foam packing material in place, lift the AmpLink unit from the shipping
container. Place the AmpLink unit on a level surface and remove the foam packingmaterial from the unit.
4 Inspect the AmpLink unit for signs of damage. Report any damage to STI CustomerService.
5 Retain the shipping container and all packing materials for reuse. Store the shipping
container in a dry place.
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
22/38
Chapter 3: Installing the AmpLink 1900i-F 22
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Mounting the AmpLink 1900i-F
The unboxed AmpLink unit weighs 41 lbs. To prevent injury to personnel anddamage to equipment, it is recommended that two people are available to movethe AmpLink unit.
Labels are provided to mark each AmpLink unit for identification: Alpha, Beta,and Gamma.
A mounting kit is required to properly mount the AmpLink unit. STI offers two mounting
options:
Equipment rack shelf(part number 018-0216):
The two-piece equipment rack shelf supports up to three AmpLink units in a 19equipment rack. A 23 equipment rack shelf is also available (part number
MK-AL1900iF-23ERS).
Cable ladder kit (part number 018-0217):If equipment rack space is limited, STI offers a cable ladder kit to mount up to three
AmpLink units longitudinally or transversely below the cable ladder. A second, low
cost, cable ladder kit is also available to mount the AmpLink units longitudinally only(part number 018-0217-002). Contact STI Customer Service for pricing and
availability.
Mounting instructions and hardware are included with each mounting kit. Contact STICustomer Service for pricing and availability.
Connecting Wires
Connecting the Safety Ground Wire
Equipment required: Materials required: Safety ground wire (6 AWG)
Tools required: Wrench, 7/16 Allen wrench, 3/16 Wire stripper Wire cutter
1 Using a wire stripper and a wire cutter, strip and cut the safety ground wire to properlength.
2 Using an Allen wrench (3/16), loosen the ground lug screw, insert the safety ground
wire into the cavity, and tighten the ground lug screw until secure.
3 Connect the other end of the safety ground wire to the base station equipment
ground or the equipment single point ground plate.
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
23/38
Chapter 3: Installing the AmpLink 1900i-F 23
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Connecting the Power Wire
Keep the power wire to less than 30 feet in length.
Before proceeding with the power wire connection, set the circuit breaker to theopen or off position. Failure to comply may result in personnel injury.
Equipment required: Materials required: Power wire (16 AWG)
Tools required: Wire stripper Wire cutter Flat blade screwdriver, 1/8
1 Remove the fuses from the AmpLink unit.
2 Select a circuit breaker in the power panel. Operate (open) the circuit breaker to turn
off power in the circuit.
3 Using a wire stripper, strip the power wires insulation (1/2) and twist the strands.
4 Using a flat blade screwdriver (1/8), loosen the screw on the terminal block.
5 Insert the power wire into the terminal block while carefully maintaining the correct
voltage polarity. Do not close the circuit breaker at this time.
+
-
+27V
0V
+
--48V
0V
Figure 8. Voltage polarity for 27 VDC (left) and -48 VDC power (right)
Although the AmpLink unit accepts positive or negative DC power, care must betaken to maintain proper voltage polarity. Connect the positive voltage to the +terminal only and the negative voltage to the - terminal only.
6 Tighten the screw and verify that the power wire is securely clamped to the terminal.
7 Route the power wire and connect it to the base station power distribution circuitbreaker. Do not close the circuit breaker at this time.
Connecting Alarm Relays
By connecting the output of the AmpLink alarm relays to the base station alarm system,remote alarm monitoring is possible. Figure 9 shows the states of the alarm relays.
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
24/38
Chapter 3: Installing the AmpLink 1900i-F 24
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Figure 9. Alarm relay in normal and fault states
Equipment required: Materials required: Alarm wire (24 AWG)
Tools required: Wire stripper Wire cutter Flat blade screwdriver, 1/8
1 Using a wire stripper, strip the alarm wires insulation (1/2).
2 Using a flat blade screwdriver (1/8), loosen the screw on the terminal block.
3 Insert the alarm wire into the terminal block labeled C and NC or NO as required by
the base station alarm system.
4 Tighten the screw and verify that the alarm wire is securely clamped to the terminal.
5 Route the alarm wire to the base station alarm connection point. Do not close the
circuit breaker at this time.
Performing Power Up
Before proceeding with power up, set the power base station distribution circuitbreaker to the open or off position. Failure to comply may result in personnelinjury.
Equipment required: Circuit breaker DMM
Materials required: Tools required:
1 Ensure the circuit breaker is set to the open or off position.
2 Remove the fuses from the fuse holders on the front panel of the AmpLink unit.
3 Set the circuit breaker to the closed or on position.
4 Using a DMM, verify that the AmpLink input voltage and polarity at the terminal block
contact reads the following: 22 VDC to 30 VDC or -42 VDC to -60 VDC.
5 After verifying proper voltage and polarity, turn the circuit breaker off, and install thefuses in the fuse holders.
6 Setting the circuit breaker to the closed or on position, apply power to the AmpLink
unit.
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
25/38
Chapter 3: Installing the AmpLink 1900i-F 25
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Performing Functional Checks
Before performing any functional checks, the AmpLink unit must be in Normal operation,indicated by the PWRLED in GREEN and the LNA1 and LNA2 LEDs turned off. If the
AmpLink fails to go into Normal operation, review the Troubleshooting Tips section on
page 32 or contact STI Technical Support for assistance.
AmpLink functional checks consist of the following tasks:
Alarm relay test Test generator calibration data
RF system test
Equipment required: RF Signal Generator Spectrum Analyzer
Materials required: 7/16 DIN-type barrel connector
adapter Test cables
Tools required:
Before proceeding with the functional checks, turn on the RF Signal Generatorand the Spectrum Analyzer to warm them up. Consult the equipment operator
manuals for proper test equipment warm up time.
Alarm Relay Test
Before performing the alarm relay test, the AmpLink unit must be in Normaloperation, indicated by the PWRLED in GREEN and the LNA1 and LNA2 LEDsturned off.
1 Power off the AmpLink unit to place the alarm relay in alarm condition. Verify that the
base station alarm is activated. The alarm relay is now in alarm condition, indicatedby the PWRLED turned off. Verify that the base station alarm is activated.
2 Power on the AmpLink unit to return to Normal operation (PWRLED in GREEN and
the LNA1 and LNA2 LEDs turned off). Verify that the base station alarm is no longeractivated.
Test Generator Calibration Data
A signal power measurement is the reference level for verifying AmpLink RF path gain and
loss values.
1 Allow the RF Signal Generator and the Spectrum Analyzer to warm up.
2 Set the RF Signal Generator to output a CW signal:
Rx path1850 MHz to 1910 MHz
Power level set to -50+1 dBm
Tx path1930 MHz to 1990 MHz
Power level set to -50+1 dBm
3 Connect the RF Signal Generator output to the Spectrum Analyzer as shown in Figure
10. Substitute a 7/16 DIN-type barrel connector adapter for the AmpLink unit.
7/16 DIN-male to N-type female connector adapters may be required to connectthe RF Signal Generator and the Spectrum Analyzer to the barrel adapter or tothe AmpLink unit.
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
26/38
Chapter 3: Installing the AmpLink 1900i-F 26
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Figure 10. Test generator calibration data setup block diagram
4 Measure the signal frequency and power level, and note both values.
5 Remove the 7/16 DIN-type barrel connector adapter.
RF System Test
The RF jumper cables between the AmpLink unit and the base station are notconnected for the RF System Test.
Re c e i v e P a t h
1 Remove the ESD covers from the RF connectors, and store them in the shipping
container.
2 Connect the test equipment to the AmpLink unit as shown in Figure 11:
RF Signal Generator out to ANTENNA CH1 Spectrum Analyzer in to BTS CH1
ANTENNACH 1
BTSCH 1
AmpLink 1900i-F
RFSignal Generator
Spectrum Analyzer
AmpLink 1900i-F
Figure 11. RF system test connections for receive / transmit paths
3 Set the RF Signal Generator to the receive center band frequency of 1880 MHz and
power level of -50+1 dBm.
4 Apply power to the AmpLink unit.
5 Measure RF power level as shown on the Spectrum Analyzer at the center band
frequency of 1880 MHz:
Pass: Gain > 12 dB Fail: Gain < 12 dB
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
27/38
Chapter 3: Installing the AmpLink 1900i-F 27
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
In an event of a failure, you must return the AmpLink unit to STI. See theInstructions for Return Shipment section on page 34 for more information.
6 Repeat steps 2-5 for Channel 2 (Rx only).
T r a n sm i t P a t h
Complete the Receive Path test before continuing with the Transmit Path test.
1 Connect the test equipment to the AmpLink unit:
RF Signal Generator out to BTS CH1 Spectrum Analyzer in to ANTENNA CH1
2 Measure RF power levels as shown on the Spectrum Analyzer at the center band
frequency of 1960 MHz:
Pass: Gain < -1 dB
Fail: Gain > -1 dB
In an event of a failure, you must return the AmpLink unit to STI. See theInstructions for Return Shipment section on page 34 for more information.
3 Repeat steps 1-2 for Channel 2 (Tx only).
If you have access to a Spectrum Analyzer with a tracking generator, or RFSignal Generator with sweep mode, you can set the unit to sweep across1500 MHz to 2300 MHz for the RF system test. You should see displays similarto those shown in Figure 12.
AmpLink 1900e-F
Antenna Port to BTS Port
-80
-60
-40
-20
0
20
1800 1850 1900 1950 2000 2050
MHz
dB
Figure 12. Swept response for receive / transmit paths
Rx
Tx
AmpLink 1900i-F
MHz
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
28/38
Chapter 3: Installing the AmpLink 1900i-F 28
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Wiring for Redundancy
To provide sector-by-sector redundancy, main and diversity signals from a single sectorshould not be connected to the same AmpLink unit. In an event of a single unit failure, a
configuration with two RF paths from one sector, processed by two different AmpLink units,
will keep the sector operational. Figure 13 shows one way of assigning the channels forimproved reliability.
Figure 13. Wiring for redundancy
Connecting RF Jumper Cables
This section applies to a sectored base station (6-receive channel). ThreeAmpLink units are required.
Do not apply DC voltage to any RF port.
Turn off the transmit power in the base station before proceeding.
Before proceeding with RF jumper cable connections, the AmpLink unit must bein Normal operation, indicated by the PWRLED in GREEN and the LNA1 andLNA2 LEDs turned off.
This section assumes that the antenna cables connected to the base station willbe disconnected and used for the top row of the AmpLink unit.
From this point forward, call service may be interrupted.
Equipment required: Materials required: RF jumper cables Nylon wire ties Tape / Labels
Tools required: Torque wrench
1 Prepare a set of RF jumper cables that will reach from the AmpLink unit to the base
station Main and Diversity antenna connections. Sweep the RF jumper cables to verifyperformance. Label the RF jumper cables with tape or labels for identification.
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
29/38
Chapter 3: Installing the AmpLink 1900i-F 29
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
2 Turn off the base station transmit power.
3 In the first receive path, reuse the existing RF jumper cable to connect between thebase station Tx / Rx input and the main AmpLink BTS CH1 output.
4 Using a new RF jumper cable, connect between the antenna and the AmpLinkANTENNA CH1 port.
5 Using a torque wrench, torque the 7/16 DIN-type connectors to 221+4 in-lbs.
6 Repeat steps 3-5 for the remaining RF connections (ANTENNA CH2, BTSCH2).
7 Repeat steps 1-5 for the remaining AmpLink units.
8 Turn on the base station transmit power. Verify site performance by making testcalls.
9 Dress the RF jumper cables with nylon wire ties as required.
Figure 14. RF jumper cable connections pre- and post-AmpLink installation
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
30/38
Chapter 3: Installing the AmpLink 1900i-F 30
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
31/38
Chapter 4: AmpLink 1900i-F Maintenance and Troubleshooting Tips 31
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Chapter 4: AmpLink 1900i-F Maintenance and
Troubleshooting Tips
Overview
Although the AmpLink unit is maintenance free, periodic inspections are suggested. Thefrequency of inspections depends on the installation site conditions. If a problem is found
with the AmpLink unit, basic troubleshooting tips for the most common problems andpossible resolutions are provided. Contact STI Technical Support if the problem continues
with the AmpLink unit, or the problem at hand is not available in this chapter.
If the AmpLink problem continues, the unit must be returned to STI. Instructions are
provided at the end of this chapter to return a failed AmpLink unit. Contact STI CustomerService for questions regarding AmpLink replacement or repair.
Periodic AmpLink 1900i-F Maintenance Checklist
Periodic inspections of the installation site are suggested. Review the following AmpLinkmaintenance checklist to assist in the inspection.
Mounting hardware: Check that the AmpLink units are securely mounted. RF jumper cables: Check the RF jumper cables for damage. Replace RF jumper
cables as required. Wire connections: Check the safety ground, power, and alarm wires for damage.
Replace wires as required.
PWRand LNA1 or LNA2 LEDs: Check the PWR, LNA1 and LNA2 LEDs:
Table 8. PWR / LNA1 and LNA2 LED Troubleshooting
State PWR LED LNA1 / LNA2 LED Description
Normal operation AmpLink unit in Normal operation.
Fault mode
If LEDs display RED, see the TroubleshootingTips section on page 32 to resolve the problem.If LEDs are off, check the power to the basestation. If the base station is powered on, theAmpLink unit may have an internal fault. ContactSTI Technical Support for assistance.
Contact STI Technical Support for any questions you may have during the inspection.
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
32/38
Chapter 4: AmpLink 1900i-F Maintenance and Troubleshooting Tips 32
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Troubleshooting Tips
Problems may occur during installation, or from hardware failures that occur duringoperation. This section identifies the most common problems, providing troubleshooting tips
to resolve them. If your specific AmpLink problem does not appear in this list, contact STITechnical Support for assistance.
Problem No. Description Page No.
1 PWRLED off. Page 33
2 Fuse blows or circuit breaker trips. Page 33
3 RED LED illuminates on any one of the following LEDs: LNA1 or
LNA2.
Page 34
4 BTS path failure (PWRLED on, and both LNA1 and LNA2 LEDsoff, but no signal is coming through).
Page 34
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
33/38
Chapter 4: AmpLink 1900i-F Maintenance and Troubleshooting Tips 33
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Problem 1 PWR LED off.
Cause 1.1 DC power wire connection is not complete / correct.Solution 1.1a Check power wire for proper continuity. Replace wires if
necessary.Solution 1.1b Check power wires for continuity. Replace wires if necessary.
Solution 1.1c Check that the DC breaker is on and supplying power. Replace
the breaker if necessary.
Cause 1.2 Fuse blown.Solution 1.2 Replace fuse (3A) and power on the AmpLink unit again.
Cause 1.3 Other.
Solution 1.3 Contact STI Technical Support for assistance.
Problem 2 Fuse blows or circuit breaker trips.
Cause 2.1 Incorrect voltage polarity applied.Solution 2.1 Check that the voltage polarity matches the labels on the
terminal block. If the polarity is correct, then continue withCause 2.2. If the polarity is incorrect, change the polarity,
replace the fuse, and / or reset the circuit breaker. Before youremove the fuse, turn off the circuit breaker to prevent injury.
Cause 2.2 Incorrect voltage applied.Solution 2.2 Remove the fuse, close the circuit breaker, and check the
voltage on the terminal block. Before you remove the fuse,turn off the circuit breaker to prevent injury. If the voltage
does not fall between 22 VDC to 30 VDC or -42 VDC to-60 VDC, contact STI Technical Support for assistance.
If the voltage lies within limits and the voltage polarity iscorrect, but the circuit breaker continues to trip, contact STI
Technical Support for assistance. See the Performing PowerUp section on page 24.
Cause 2.3 Wrong circuit breaker rating.
Solution 2.3 Replace the fuse and try again. Before you remove the fuse,
turn off the circuit breaker to prevent injury. If the circuitbreaker blows / trips, check the rating. The circuit breaker
rating should read between 3A to 5A (for both 27 VDC and
-48 VDC). Replace the circuit breaker as required.
Cause 2.4 Other.
Solution 2.4 Contact STI Technical Support for assistance.
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
34/38
Chapter 4: AmpLink 1900i-F Maintenance and Troubleshooting Tips 34
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Problem 3 RED LED illuminates on any one of the following LEDs:LNA1 or LNA2.
Cause 3.1 Failed LNA.
Solution 3.1 Contact STI Technical Support for assistance.
Cause 3.2 Other.
Solution 3.2 Contact STI Technical Support for assistance.
Problem 4 BTS path failure (both LNA1 and LNA2 LEDs turned and
input present, but no signal coming through).
Cause 4.1 External RF jumper cable failure.Solution 4.1a Check RF jumper cables for proper mating and secure
connections.
Solution 4.1b Check RF jumper cables for proper continuity of the center
conductor and ground.Solution 4.1c Check RF jumper cables for proper return loss and
Distance-to-Fault.
Cause 4.2 Wrong BTS test frequency.
Solution 4.2 Set the BTS test frequency as follows:
1930 MHz to 1990 MHz
Power level set to -50+1 dBm
This setting tests the Tx path and measures -1 dB or less. Ifthis test passes, retry the Rx path at any passband frequency
(1850 MHz to 1910 MHz).
Cause 4.3 Other.
Solution 4.3 Contact STI Technical Support for assistance.
Instructions for Return Shipment
In an event of a failure, return the AmpLink unit to STI for repair.
1 Contact STI Customer Service for a Return Material Authorization (RMA) number.
Provide the following information:
Model / serial numbers (located on the rear of the AmpLink unit)
Comprehensive description as to the nature of the return
2 STI will send the RMA number and additional shipping instructions. Follow theinstructions provided in the RMA paperwork to return the AmpLink unit to STI.
Failure to properly package the AmpLink unit could result in significant shippingdamage. STI is not responsible for shipping damage due to improper packaging.Keep the original shipping container, or request a new one from STI.
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
35/38
Appendix A: AmpLink 1900i-F Specifications 35
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Appendix A: AmpLink 1900i-F Specifications
Table A1. AmpLink 1900i-F Specifications
Item Characteristic
Power Requirements
Input power voltage (27 VDC nominal) 22 VDC to 30 VDC-42 VDC to -60 VDC
Input power interface Screw terminal block
Fuses 3A fast-blow (two fuses required)
Maximum input power at -10C to 60C ambienttemperature
15W maximum
Frequencies of Operation
Rx: 1850 MHz to 1910 MHzTx: 1930 MHz to 1990 MHz
Dimensions
10 (H) x 5.75 (W) x 22.5 (D)
AmpLink 1900i-F Weight41 lbs
Environmental
Operating temperature 0C to +50C
Operating humidity 0% to 90% (non-condensing)
Operating altitude From sea level to 15,000 feet
Storage temperature (non-operating) -30C to +70C
Storage humidity (non-operating) 10% to 95% RH non-condensing at 40C
Storage altitude (non-operating) From sea level to 10,000 feet
ESD-sensitive; requires electrostatic dischargeprotection
The AmpLink unit contains components that are subject todamage from ESD.
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
36/38
Appendix A: AmpLink 1900i-F Specifications 36
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
37/38
Index 37
AmpLink 1900i-F Operation & Installation Manual STI Technical Support 1.800.727.3648
Index
A
about the AmpLink 1900i-F ................................11about this manual ...............................................9alarm
connection input terminal strip ........................14alarm relay.......................................................23
functional check ............................................25states...........................................................24
ANTENNA connectors.........................................15
Bbenefits ...........................................................11block diagram
functional .....................................................13RF jumper cable connection pre- and post-
AmpLink installation ...................................29RF signal flow................................................12
BTS connectors.................................................15BTS path failure ................................................34
Ccable ladder......................................................22cable ladder kit .................................................18caution symbol .................................................10circuit breaker trips ...........................................33connecting RF jumper cables ..............................28connecting wires ...............................................22
alarm...........................................................23power...........................................................23safety ground................................................22
contacting STI ..................................................10customer service...............................................10
Ddimensions.......................................................35
EElectrostatic Discharge.......................................10environmental specifications...............................35equipment configuration ....................................12equipment rack shelf ................................... 18, 22equipment specifications....................................35equipment supplied ...........................................19
FFAULT LEDs
LNA1 and LNA2 .............................................14fault mode........................................................31frequencies, operation .......................................35front view
alarm connection terminal strip .......................14fuses............................................................14GND.............................................................14LNA1 / LNA2 LEDs .........................................14power connection terminal strip .......................14PWR LED ......................................................14
functional checks
alarm relay test ............................................ 25RF system test, receive path test .................... 26RF system test, transmit path test................... 27test generator calibration data ........................ 25
functional description ........................................ 12alarm........................................................... 13power.......................................................... 13RF signal flow ............................................... 12
fuse blows ....................................................... 33fuses..........................................................14, 35
Ggeneral safety
caution ........................................................ 10note ............................................................ 10warning ....................................................... 10
Iinstallation procedures
connecting alarm wire.................................... 23connecting power wire ................................... 23connecting RF jumper cables .......................... 28connecting safety ground wire ........................ 22mounting ..................................................... 22performing functional checks .......................... 25performing power up ..................................... 24unpacking AmpLink 1900i-F............................ 21
installation requirementsequipment supplied
AmpLink 1900i-F ....................................... 19quick start installation guide ....................... 19
STI CD ..................................................... 19material requirements ................................... 19mounting requirements.................................. 18site requirements.......................................... 18site survey ................................................... 17test equipment requirements.......................... 20tool requirements.......................................... 20
LLEDs
fault mode.................................................... 31LNA1 ........................................................... 14LNA2 ........................................................... 14normal operation........................................... 31PWR ............................................................ 14
LNA1 / LNA2 LEDs ............................................ 14
Mmaintenance checklist ....................................... 31material requirements....................................... 19mounting
AmpLink 1900i-F........................................... 22requirements ................................................ 18
-
7/28/2019 830-0026-4P_AL1900iF_OpInsManual
38/38
Index 38
Nnormal operation...............................................31note symbol .....................................................10
Ppower
connecting....................................................23
connection input terminal strip ........................14description....................................................13input voltage.................................................35maximum.....................................................35
powering up .....................................................24PWR LED..........................................................14PWR LED off .....................................................33
Rrear view
ANTENNA connectors .....................................15BTS connectors .............................................15
RED LED illuminates on any one of the followingLEDs, LNA1 or LNA2.......................................34
redundancy ......................................................28Return Material Authorization (RMA) ....................34return shipments...............................................34RF system test..................................................26
Ssafety.......................................See general safety
site requirements ............................................. 18site survey....................................................... 17system configuration......................................... 12
Ttechnical support .............................................. 10test equipment requirements ............................. 20test generator calibration data ........................... 25
tool requirements, installation............................ 20transmit path test............................................. 27troubleshooting ................................................ 32
BTS path failure ............................................ 34circuit breaker trips ....................................... 33fuse blows.................................................... 33PWR LED off ................................................. 33RED LED illuminates on any one of the following
LEDs, LNA1 or LNA2................................... 34
Uunpacking AmpLink 1900i-F............................... 21
Vvoltage polarity, 27 VDC and -48 VDC................. 23
Wwarning symbol................................................ 10warranty............................................................ 2weight............................................................. 35wiring for redundancy ....................................... 28