A 1 2 3 4 5 6 7 8 B C D 1 2 3 4 5 6 7 8 A B C D TITLE SCALE DWG NO. CAD NO. SHEET DRAWN CHECKED APPROVED MAX. THIRD ANGLE PROJECTION POWER SYSTEMS, KOHLER, WI 53044 U .S.A. THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO. PROPERTY AND MUST NOT BE USED EXCEPT IN CONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OF DESIGN OR INVENTION ARE RESERVED. 1521 59.9 [ ] 4094 161.2 [ ] 260.0 10.24 [ ] 1194 47.0 [ ] 1300 51.2 [ ] 53 2.1 [ ] 100 3.9 [ ] 800 31.5 [ ] 559 22.0 [ ] 78 3.1 [ ] 648 25.5 [ ] 559 22.0 [ ] 523 20.6 [ ] 473 18.6 [ ] 761 30.0 [ ] 1339 52.7 [ ] 1893 74.5 [ ] 2472 97.3 [ ] 469 18.5 [ ] DOOR CLEARANCE TYP 893 35.2 [ ] 1762 69.4 [ ] 4123 162.3 [ ] ENGINE EXHAUST 152.4 6.00 [ ] PRO-E METRIC DIMENSION PRINT 230-300KW JD 0.06 1 of 4 ADV-7644 D UNLESS OTHERWISE SPECIFIED - 1) DIMENSIONS ARE IN MILLIMETERS 2) TOLERANCES ARE: X.XX # 0.25 X.X # 1.0 X # 1.5 SURFACE FINISH ANGLES # 0 $ 30' APPROVALS DATE DJV 10-24-08 CWF 10-24-08 SLJ 10-24-08 REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY E 10-31-12 SHEET 2 WAS SHEET1, ADDED SHEET 1 [CT28612] CEK F 2-5-13 (A-1) 1-4 WAS 1-2, SEE SHEET 3 AND 4 [CT32174] SAM G 8-4-17 (D-6) DIM. n 152.4 (6.00) ADDED [CT177004] SRM 230-300 MODEL JOHN DEERE TIER III NOTE: 1. IF STANDARD TANK IS ORDERED, ENCLOSURE MOUNTS DIRECTLY TO TANK 2. IF STATE TANK IS ORDERED, TANK MOUNTS BELOW SKID 3. TANK MAY EXTEND BEYOND ENCLOSURE (DISCHARGE END ONLY) 4. FOR STUB-UP ACCESS DURING INSTALLATION THE REAR ENCLOSURE PANEL SHOULD BE REMOVED. OIL/COOLANT DRAIN (BOTH SIDES) AIR INTAKE AIR INTAKE AIR DISCHARGE MODEL ENCLOSURE WEIGHT KG [LBS] STEEL WEATHER 363 [800] STEEL SOUND 386 [850] ALUMINIUM SOUND 238 [525]

Transcript of 8 7 6 5 4 3 2 1 - Kohler Co.resources.kohler.com/power/kohler/industrial/pdf/adv7644.pdf · metric...

A

12345678

B

C

D

12345678

A

B

C

D

TITLE

SCALE

DWG NO.

CAD NO. SHEET

DRAWN

CHECKED

APPROVED

MAX.

THIRD ANGLEPROJECTION

POWER SYSTEMS, KOHLER, WI 53044 U .S.A.

THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.

1521 59.9[ ]

4094 161.2[ ]

260.0

10.24

[]

119447.0[ ]

130051.2[ ]

532.1[ ] 100

3.9[ ]80031.5[ ]

55922.0[ ]

783.1[ ]

64825.5[ ]

55922.0[ ]

52320.6[ ]

473 18.6

[]

761 30.0[ ]

1339 52.7[ ]

1893

74.5

[]

2472 97.3[ ]469 18.5[ ]

DOOR CLEARANCE

TYP

893

35.2

[]

1762

69.4

[]

4123 162.3[ ]

ENGINE EXHAUST152.4 6.00[ ]

PRO-EMETRIC

DIMENSION PRINT 230-300KW JD0.06 1 of 4

ADV-7644 D

UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:

X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'

APPROVALS DATE

DJV

10-24-08

CWF 10-24-08

SLJ 10-24-08

REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY

E 10-31-12 SHEET 2 WAS SHEET1, ADDED SHEET 1 [CT28612] CEK

F 2-5-13 (A-1) 1-4 WAS 1-2, SEE SHEET 3 AND 4 [CT32174] SAM

G 8-4-17 (D-6) DIM. �n�152.4 (6.00) ADDED [CT177004] SRM

230-300 MODELJOHN DEERE TIER III

NOTE: 1. IF STANDARD TANK IS ORDERED, ENCLOSURE MOUNTS DIRECTLY TO TANK 2. IF STATE TANK IS ORDERED, TANK MOUNTS BELOW SKID 3. TANK MAY EXTEND BEYOND ENCLOSURE (DISCHARGE END ONLY) 4. FOR STUB-UP ACCESS DURING INSTALLATION THE REAR ENCLOSURE PANEL SHOULD BE REMOVED.

OIL/COOLANT DRAIN(BOTH SIDES)

AIR INTAKE

AIR INTAKE

AIR DISCHARGE

MODELENCLOSURE WEIGHT

KG [LBS]

STEEL WEATHER 363 [800]

STEEL SOUND 386 [850]

ALUMINIUM SOUND 238 [525]

A

12345678

B

C

D

12345678

A

B

C

D

TITLE

SCALE

DWG NO.

CAD NO. SHEET

DRAWN

CHECKED

APPROVED

MAX.

THIRD ANGLEPROJECTION

POWER SYSTEMS, KOHLER, WI 53044 U .S.A.

THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.

B 10-7-10 (D-6) 523 WAS 588, (C-6) 761 WAS 713, (B-2)4121.4 WAS 4100.0 [90099-5] RJS

SAM

(A-1) 2-4 WAS 2-2, SEE SHEET 3 AND 4 [CT32174]

783.1[ ]

64825.5[ ]1194 47.0[ ]

1300 51.2[ ]1965.0 [77.36]

260.0

10.24

[]

1521.0 59.88[ ]

4094.0 161.18[ ]

53 2.1[ ] 100 3.9[ ]

800 31.5[ ]

55922.0[ ]

55922.0[ ]

DOOR CLEARANCE

TYP

912

35.9

[]

52320.6[ ]

473

18.6

[]

761 30.0[ ]

1338 52.7[ ]

1883

74.1

[]

4121 162.3[ ]

1759

69.2

[]

DOOR OPENING859 33.8[ ]

1061 [41.8]

DOOR OPENING

ENGINE EXHAUST152.4 6.00[ ]

PRO-EMETRIC

DIMENSION PRINT 230-300KW JD0.06 2 of 4

ADV-7644 D

UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:

X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'

APPROVALS DATE

DJV

10-24-08

CWF 10-24-08

SLJ 10-24-08

REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY

C 3-16-11 (A-8) 260.0 WAS 200.0 [91189] SAM

D 6-20-11 (C-3) STUB-UP NOTE ADDED [91752]

E 10-31-12 SHEET2 WAS SHEET 1, ADDED SHEET 1 [CT28612] CEK

F 2-5-13 SAM

G 8-4-17 (C-5) DIM. �n�152.4 (6.00) ADDED; SEE SHEET 1

[CT177004] SRM

230-300 MODELJOHN DEERE TIER III

IBC/ OSHPD

NOTE: 1. IF STANDARD TANK IS ORDERED, ENCLOSURE MOUNTS DIRECTLY TO TANK 2. IF STATE TANK IS ORDERED, TANK MOUNTS BELOW SKID 3. TANK MAY EXTEND BEYOND ENCLOSURE (DISCHARGE END ONLY) 4. FOR STUB-UP ACCESS DURING INSTALLATION THE REAR ENCLOSURE PANEL SHOULD BE REMOVED.

DIMENSIONS IN [] ARE IN ENGLISH EQUIVALENTS.

AIR DISCHARGE

OIL/COOLANT DRAIN(BOTH SIDES

AIR INTAKEAIR INTAKE

12X �n�25.4 [1.00]

MODELENCLOSURE WEIGHT

KG [LBS]

STEEL WEATHER 363 [800]

STEEL SOUND 386 [850]

ALUMINIUM SOUND 238 [525]

A

12345678

B

C

D

12345678

A

B

C

D

TITLE

SCALE

DWG NO.

CAD NO. SHEET

DRAWN

CHECKED

APPROVED

MAX.

THIRD ANGLEPROJECTION

POWER SYSTEMS, KOHLER, WI 53044 U .S.A.

THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.

KEM

230-300 MODELJOHN DEERE TIER III

NOTE: 1. IF STANDARD TANK IS ORDERED, ENCLOSURE MOUNTS DIRECTLY TO TANK 2. IF STATE TANK IS ORDERED, TANK MOUNTS BELOW SKID 3. TANK MAY EXTEND BEYOND ENCLOSURE (DISCHARGE END ONLY) 4. FOR STUB-UP ACCESS DURING INSTALLATION THE REAR ENCLOSURE PANEL SHOULD BE REMOVED.

OIL/COOLANT DRAIN(BOTH SIDES)

AIR INTAKE

AIR INTAKE

AIR DISCHARGE 761 30.0[ ]

1339 52.7[ ]

260

10.2

[]

53 2.1[ ]

1194 47.0[ ]

1300 51.2[ ]

78 3.1[ ]648 25.5[ ]

55922.0[ ]100 3.9[ ]

80031.5[ ]

55922.0[ ]

4094 161.2[ ]

1521 59.9[ ]

469 18.5[ ] 2472 97.3[ ]

DOOR OPENING859 33.8[ ]

DOOR OPENING

1062

41.8

[]

473.04

18.624

[]

1811 71.3[ ]

1432

56.4

[]

PLENUM PASS THROUGH

1798

70.8

[]

PLENUM779 30.7[ ]

40.1

[]

50.2

[]

112 4.4[ ]

41

1.6

[]

100 3.9[ ]

103 4.1[ ]

DOOR CLEARANCE

TYP

891

35.1

[]

4123 162.3[ ]

1755

69.1

[]

PRO-EMETRIC

DIMENSION PRINT 230-300KW JD

0.06 3 of 4

ADV-7644 D

UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:

X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'

APPROVALS DATE

SAM 2-5-13

KEM 2-5-13

2-5-13

REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY

F 2-5-13 SHEET 3 AND CA AQMD MODEL ADDED, SEE SHEET 4 [CT32174]

DJV

G 8-4-17 SEE SHEET 1 & 2 [CT177004] SRM

CA AQMD READY ENCLOSURES(NO SILENCER)

EXHAUST OUTLETSCALE 0.400

MODELENCLOSURE WEIGHT

KG [LBS]

STEEL WEATHER 302 [665]

STEEL SOUND 325 [715]

ALUMINIUM SOUND 177 [390]

A

12345678

B

C

D

12345678

A

B

C

D

TITLE

SCALE

DWG NO.

CAD NO. SHEET

DRAWN

CHECKED

APPROVED

MAX.

THIRD ANGLEPROJECTION

POWER SYSTEMS, KOHLER, WI 53044 U .S.A.

THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.

KEM

SHEET 4 AND CA AQMD MODEL ADDED, SEE SHEET 3 [CT32174]

230-300 MODELJOHN DEERE TIER III

IBC/ OSHPD

NOTE: 1. IF STANDARD TANK IS ORDERED, ENCLOSURE MOUNTS DIRECTLY TO TANK 2. IF STATE TANK IS ORDERED, TANK MOUNTS BELOW SKID 3. TANK MAY EXTEND BEYOND ENCLOSURE (DISCHARGE END ONLY) 4. FOR STUB-UP ACCESS DURING INSTALLATION THE REAR ENCLOSURE PANEL SHOULD BE REMOVED.

DIMENSIONS IN [] ARE IN ENGLISH EQUIVALENTS.

AIR DISCHARGE

OIL/COOLANT DRAIN(BOTH SIDES

AIR INTAKEAIR INTAKE

12X �n�25.4 [1.00]

DOOR CLEARANCE

TYP

912

35.9

[]

761 30.0[ ]

1521 59.9[ ]

2018 79.4[ ]

4094 161.2[ ]

53 2.1[ ]

1300 51.2[ ]

1194 47.0[ ]

100 3.9[ ]

80031.5[ ]

55922.0[ ]

55922.0[ ] 648 25.5[ ] 78 3.1[ ]

2019

79.5

[]

4121 162.3[ ]1338 52.7[ ]DOOR OPENING859 33.8[ ]

DOOR OPENING

1059

41.7

[]

1822 71.7[ ]

1432

56.4

[]

1811 71.3[ ]

PLENUM779 30.7[ ]

PLENUM PASS THROUGH

1802

70.9

[]

12

0.5

[]

112 4.4[ ]

50.2

[]

100 3.9[ ] 41

1.6

[]

103 4.1[ ]

PRO-EMETRIC

DIMENSION PRINT 230-300KW JD

0.06 4 of 4

ADV-7644 D

UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:

X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'

APPROVALS DATE

SAM 2-5-13

KEM 2-5-13

2-5-13

REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY

F 2-5-13

SAM

G 8-4-17 SEE SHEET 1 & 2 [CT177004] SRM

CA AQMD READY ENCLOSURES(NO SILENCER)

EXHAUST OUTLETSCALE 0.300

MODELENCLOSURE WEIGHT

KG [LBS]

STEEL WEATHER 302 [665]

STEEL SOUND 325 [715]

ALUMINIUM SOUND 177 [390]