79 Readville St. Boston, MA 02136 800-983-2420.

42
79 Readville St. 79 Readville St. Boston, MA 02136 Boston, MA 02136 800-983-2420 800-983-2420 www.Bio-Cascade.com www.Bio-Cascade.com

Transcript of 79 Readville St. Boston, MA 02136 800-983-2420.

Page 1: 79 Readville St. Boston, MA 02136 800-983-2420.

79 Readville St.79 Readville St.

Boston, MA 02136Boston, MA 02136

800-983-2420800-983-2420

www.Bio-Cascade.comwww.Bio-Cascade.com

Page 2: 79 Readville St. Boston, MA 02136 800-983-2420.

About us.

Bio-Cascade Inc. specializes in solutions for air and water

pollution using the patented bio-systems

that are known as the CAP™ -Clean Air Plant

and CWP™-Clean Water Plant

  

Page 3: 79 Readville St. Boston, MA 02136 800-983-2420.

Along with the bio-detergent formula BioOx® we can provide a guaranteed solution to any indoor

or outdoor air quality or waste process

water treatment problem.

Page 4: 79 Readville St. Boston, MA 02136 800-983-2420.

Our systems neutralize the charged particles which carry air pollution, draw them into the unit where they are destroyed by the

Bio-Detergent

No harmful chemicals and no messy filters to change

Page 5: 79 Readville St. Boston, MA 02136 800-983-2420.

CAP™ Clean Air Plant History

1996: Introduction of CAP-Clean Air Plant for control of Indoor Air

Quality. World 1st and only Biological IAQ Control System.

2002: Business Achievement Award:

Technology Merit Award for Biological Air and Water Cleaning Systems, Environmental Business

Journal.

Page 6: 79 Readville St. Boston, MA 02136 800-983-2420.

Bio-Hygienics

Contaminants and odors that are persistent travel on particulates.

Small particles, the ones which are most harmful, are resistant to normal

air flow and cannot be vented.

Most large particles will travel with air flow and can be vented.

Page 7: 79 Readville St. Boston, MA 02136 800-983-2420.

These particulates are electrically charged.

Bio-hygienics: continued

For these reasons, many odors and fumes linger even when an area is

exhausted.

Their motion is controlled by electrical fields not by air flow.

Page 8: 79 Readville St. Boston, MA 02136 800-983-2420.

CAP™ creates an electrically neutral “clean zone.”

Contaminants, both positively and negatively charged, are attracted to

this neutral clean zone, where they are captured in the unit

and biologically oxidized.

Patented Technology

Page 9: 79 Readville St. Boston, MA 02136 800-983-2420.

““Bio-Detergent”

BioOx® All Natural Media is a patented formula usingMicrobes and Enzymes.

The formula uses what is called immobilized cell technology

Page 10: 79 Readville St. Boston, MA 02136 800-983-2420.

Most comparable Bio-Oxidation processes have space and time

constraints. Most other systems use "free cell" technology, which is slow,

prohibits indoor applications, and causes residual

disposal (sludge) problems.

Page 11: 79 Readville St. Boston, MA 02136 800-983-2420.

Combined with the design of our patented BioStack® Cartridge 

used on our bio-systems, immobilization technology is the

breakthrough that brings the power of enzymes and micro

organisms together.

Page 12: 79 Readville St. Boston, MA 02136 800-983-2420.

Immobilized biofilms are the subset of our immobilization

technology.

Immobilized cells are far superior and more intelligent than free

cells.

Page 13: 79 Readville St. Boston, MA 02136 800-983-2420.

Here is why....

They arrange back to back and are not exposed to attacks by chemicals or other microbes.

They form a protective gel layer which makes them further resistant to highly toxic compounds.

Page 14: 79 Readville St. Boston, MA 02136 800-983-2420.

They do not settle to the bottom of the reservoir like free cells.

They remain in the biofilm.

They do not wash out at high liquid flow rates when used to

clean either air or water.

Page 15: 79 Readville St. Boston, MA 02136 800-983-2420.

The biofilm is reusable. Water or air may be recycled over the same

Biofilm thousands of times.

Page 16: 79 Readville St. Boston, MA 02136 800-983-2420.

Our microbes are fully grown and need no food source.

Therefore, they do not produce a residual waste other than a small

amount of CO2 and water.  

They will sustain themselves until theyhave pollution to consume.

This is unlike free cell technology.

Page 17: 79 Readville St. Boston, MA 02136 800-983-2420.

BioOx® is added to our systems based on a  formula and amount of

pollution being consumed.

This formula will digest any organic containment, it will also render any no organic material

harmless.

Page 18: 79 Readville St. Boston, MA 02136 800-983-2420.

Free Cells versus Immobilized CellsAdvantages of

Immobilization TechnologyProtective gel layer

Immobilized cellsBiosupport

FREE CELLS are exposed to attack by microorganisms and chemicals from all sides

FREE CELLS get washed out during floods or high flow

FREE CELLS sediment when pumps fail

IMMOBILIZED CELLSAre back-to-back, not exposed.Have protective gel layer.Do not sediment.Do not wash out.

Page 19: 79 Readville St. Boston, MA 02136 800-983-2420.

Time (min HC (ppm) HC (ppm) % removal

from start) In Out HC

0 2727 887 67

1 2867 921 68

2 2963 858 71

3 2895 796 73

4 2667 884 67

5 2679 827 69

6 2628 722 73

8 2517 784 69

12 2693 710 74

Hydrocarbon Vapor Destruction

In CAP90, residence time = 0.7 sec

Page 20: 79 Readville St. Boston, MA 02136 800-983-2420.

99.9+% Ammonia destruction CAP902X destruction of pure ammonia from an

industrial reactor. No vent to the outside.

Page 21: 79 Readville St. Boston, MA 02136 800-983-2420.

Will capture and destroy diesel

particles as low as .3 microns

Page 22: 79 Readville St. Boston, MA 02136 800-983-2420.

0

500000

1000000

1500000

2000000

2500000

Amount of 0.3 Micron Particles

10:19 11:20 12:21 13:22 14:23 15:24

One Minute Samples Taken Hourly - First Shift

Office Bio Cascade Particulate Study

7/24/2007

9/14/2007

Data from and Independent TestData from and Independent Test

”. CAP© 90 Used in and Office area, blue “before”, purple “after

Page 23: 79 Readville St. Boston, MA 02136 800-983-2420.

Substantial cost savings Superior technology to Carbon

and substantially more economical.

Removes and digests small particles and more that HEPA

cannot handle.

Single technology, single solution.

Page 24: 79 Readville St. Boston, MA 02136 800-983-2420.

Very low maintenance .

Can be installed modularly to meet growing demands.

Page 25: 79 Readville St. Boston, MA 02136 800-983-2420.

How CAPs Work• Contaminated air flows through the unit• Volatile organic compounds (VOCs) are drawn into the CAP where

they are oxidized• Heavy metals and particles are adsorbed onto the cartridge where

they are washed into the reservoirFan electrical cord

Water recirculation

line

Waterlevel

column

Drainplug

Submersiblewaterpump

Fan(Air outlet)

Spiral cartridge

Air inlet

Waterreservoir

Pump electrical cord

Page 26: 79 Readville St. Boston, MA 02136 800-983-2420.

Concentrated VOC stream generators

1. Ships, tanks, tankers2. Industrial Platers3. Commercial printers4. Refineries and chemical

plants5. Nail and hair salons6. Auto Mechanics and Body

Shops7. Train and Bus Stations

Page 27: 79 Readville St. Boston, MA 02136 800-983-2420.

Available technologies for concentrated VOC streams

1. Venting: doesn’t work, can be illegal, is unsafe2. Ozonizers, ionizers, UV: inject powerful

chemicals, charges, or energy toxic, can’t use with people around, don’t do gases and particles, are dangerous

3. Carbon filters: don’t do polar compounds, plug with particles, can catch fire

4. Thermal oxidizers: are dangerous, costly, can’t take sudden feed fluctuations

5. Chemical scrubbers: Cost money, use water, not reliable, can channel

6. Biological oxidizers: Technology of the future

Page 28: 79 Readville St. Boston, MA 02136 800-983-2420.

Environmentally Friendly

Systems are proven to assist in reducing costly venting and air

exchange and saving energy in the process.

Reduce or eliminate harmful pollution

you are currently venting.

Page 29: 79 Readville St. Boston, MA 02136 800-983-2420.

CWPCWP™™- Clean Water Plant may - Clean Water Plant may allow you to reuse some, or most allow you to reuse some, or most

of your waste process water.of your waste process water.

Save on water costs, conventional treatments and other

waste water disposal fees.

Page 30: 79 Readville St. Boston, MA 02136 800-983-2420.

Technology will eliminate nuisance odor and hazardous problems including :

•Anatomy labs•Waste transfer and treatment plants•Diesel and gasoline fumes•Carbon Monoxide•Mold and other spores

•Paint fumes. (Paint will even dry faster!)•Particulates

•Hair and nail salon fumes•Volatile Organic Compounds (VOC’S)

•Automotive and Body Shops

•Many more!

Page 31: 79 Readville St. Boston, MA 02136 800-983-2420.

Hospital Labs

Page 32: 79 Readville St. Boston, MA 02136 800-983-2420.

Destroys up to 500 lbs of

pollution per day!

   

   

 

CAP™ 5000

Trash Transfer station.

Neighbor Complaints stopped soon after

installation.

Page 33: 79 Readville St. Boston, MA 02136 800-983-2420.

Cage wash room at an animal lab to handle the

odors and bacteria

CAP600

Handling Tank Vent Emissions

Page 34: 79 Readville St. Boston, MA 02136 800-983-2420.

Airborne material from Cage Wash

room captured

Page 35: 79 Readville St. Boston, MA 02136 800-983-2420.

CAP85- Covers areas up to 2,000 sf

Destroys up to 10 lbs of pollution per

day

CAP600- Covers areas up to 5,000 sf with moderate

pollution levelsDestroys up to 60lbs of

pollution per day.

Page 36: 79 Readville St. Boston, MA 02136 800-983-2420.

CWP1000Flow Rate: 50gpm

Destroys up to 100lbs of water pollution per day

Other water machine sizes

CWP175- 10 gpmCWP3000- 50-100 gpmCWP6000- 100-200 gpm

Custom systems for all applications are available

Page 37: 79 Readville St. Boston, MA 02136 800-983-2420.
Page 38: 79 Readville St. Boston, MA 02136 800-983-2420.

  CWPModels

Benzene(ug/L)

Toluene(ug/L)

Ethylbenzene(ug/L)

Total xylenes(ug/L)

MTBE(ug/L)

Starting Concentration 220 300 150 570 27,000

  CWP-4000 <0.5 (ND) <1.0 (ND) <1.0 (ND) <3.0 (ND) <1.0 (ND)

CWP-1000A <0.5 (ND) <1.0 (ND) <1.0 (ND) <3.0 (ND) <1.0 (ND)

CWP-1000B <0.5 (ND) <1.0 (ND) <1.0 (ND) <3.0 (ND) <1.0 (ND)

CWP-1000C <0.5 (ND) <1.0 (ND) <1.0 (ND) <3.0 (ND) <1.0 (ND)

  ND = Not detectable

MTBE and BTEX-Contaminated Groundwater Cleaned

En

din

g C

on

cen

tra

tion

s

Property of Bio-Cascade, Inc. CONFIDENTIAL

Page 39: 79 Readville St. Boston, MA 02136 800-983-2420.

Air (CAP90) and Water (CWP175) cleaning at contaminated site

Page 40: 79 Readville St. Boston, MA 02136 800-983-2420.

Least Expensive, long term solution for Mold and Poor Air Quality

Problems

3rd Party Fungal Spore Test. NH town hall with chronic air quality problems

“Before” Test

Page 41: 79 Readville St. Boston, MA 02136 800-983-2420.

Fungal Spores results after just 6 weeks of the CAP™ system operating.

Employee Complaints stopped

“After” Test

Complete Test Results are available upon request.

Page 42: 79 Readville St. Boston, MA 02136 800-983-2420.

Thank you! For More Information

Please visit us at

www.Bio-Cascade.com