About us.
Bio-Cascade Inc. specializes in solutions for air and water
pollution using the patented bio-systems
that are known as the CAP™ -Clean Air Plant
and CWP™-Clean Water Plant
Along with the bio-detergent formula BioOx® we can provide a guaranteed solution to any indoor
or outdoor air quality or waste process
water treatment problem.
Our systems neutralize the charged particles which carry air pollution, draw them into the unit where they are destroyed by the
Bio-Detergent
No harmful chemicals and no messy filters to change
CAP™ Clean Air Plant History
1996: Introduction of CAP-Clean Air Plant for control of Indoor Air
Quality. World 1st and only Biological IAQ Control System.
2002: Business Achievement Award:
Technology Merit Award for Biological Air and Water Cleaning Systems, Environmental Business
Journal.
Bio-Hygienics
Contaminants and odors that are persistent travel on particulates.
Small particles, the ones which are most harmful, are resistant to normal
air flow and cannot be vented.
Most large particles will travel with air flow and can be vented.
These particulates are electrically charged.
Bio-hygienics: continued
For these reasons, many odors and fumes linger even when an area is
exhausted.
Their motion is controlled by electrical fields not by air flow.
CAP™ creates an electrically neutral “clean zone.”
Contaminants, both positively and negatively charged, are attracted to
this neutral clean zone, where they are captured in the unit
and biologically oxidized.
Patented Technology
““Bio-Detergent”
BioOx® All Natural Media is a patented formula usingMicrobes and Enzymes.
The formula uses what is called immobilized cell technology
Most comparable Bio-Oxidation processes have space and time
constraints. Most other systems use "free cell" technology, which is slow,
prohibits indoor applications, and causes residual
disposal (sludge) problems.
Combined with the design of our patented BioStack® Cartridge
used on our bio-systems, immobilization technology is the
breakthrough that brings the power of enzymes and micro
organisms together.
Immobilized biofilms are the subset of our immobilization
technology.
Immobilized cells are far superior and more intelligent than free
cells.
Here is why....
They arrange back to back and are not exposed to attacks by chemicals or other microbes.
They form a protective gel layer which makes them further resistant to highly toxic compounds.
They do not settle to the bottom of the reservoir like free cells.
They remain in the biofilm.
They do not wash out at high liquid flow rates when used to
clean either air or water.
The biofilm is reusable. Water or air may be recycled over the same
Biofilm thousands of times.
Our microbes are fully grown and need no food source.
Therefore, they do not produce a residual waste other than a small
amount of CO2 and water.
They will sustain themselves until theyhave pollution to consume.
This is unlike free cell technology.
BioOx® is added to our systems based on a formula and amount of
pollution being consumed.
This formula will digest any organic containment, it will also render any no organic material
harmless.
Free Cells versus Immobilized CellsAdvantages of
Immobilization TechnologyProtective gel layer
Immobilized cellsBiosupport
FREE CELLS are exposed to attack by microorganisms and chemicals from all sides
FREE CELLS get washed out during floods or high flow
FREE CELLS sediment when pumps fail
IMMOBILIZED CELLSAre back-to-back, not exposed.Have protective gel layer.Do not sediment.Do not wash out.
Time (min HC (ppm) HC (ppm) % removal
from start) In Out HC
0 2727 887 67
1 2867 921 68
2 2963 858 71
3 2895 796 73
4 2667 884 67
5 2679 827 69
6 2628 722 73
8 2517 784 69
12 2693 710 74
Hydrocarbon Vapor Destruction
In CAP90, residence time = 0.7 sec
99.9+% Ammonia destruction CAP902X destruction of pure ammonia from an
industrial reactor. No vent to the outside.
Will capture and destroy diesel
particles as low as .3 microns
0
500000
1000000
1500000
2000000
2500000
Amount of 0.3 Micron Particles
10:19 11:20 12:21 13:22 14:23 15:24
One Minute Samples Taken Hourly - First Shift
Office Bio Cascade Particulate Study
7/24/2007
9/14/2007
Data from and Independent TestData from and Independent Test
”. CAP© 90 Used in and Office area, blue “before”, purple “after
Substantial cost savings Superior technology to Carbon
and substantially more economical.
Removes and digests small particles and more that HEPA
cannot handle.
Single technology, single solution.
Very low maintenance .
Can be installed modularly to meet growing demands.
How CAPs Work• Contaminated air flows through the unit• Volatile organic compounds (VOCs) are drawn into the CAP where
they are oxidized• Heavy metals and particles are adsorbed onto the cartridge where
they are washed into the reservoirFan electrical cord
Water recirculation
line
Waterlevel
column
Drainplug
Submersiblewaterpump
Fan(Air outlet)
Spiral cartridge
Air inlet
Waterreservoir
Pump electrical cord
Concentrated VOC stream generators
1. Ships, tanks, tankers2. Industrial Platers3. Commercial printers4. Refineries and chemical
plants5. Nail and hair salons6. Auto Mechanics and Body
Shops7. Train and Bus Stations
Available technologies for concentrated VOC streams
1. Venting: doesn’t work, can be illegal, is unsafe2. Ozonizers, ionizers, UV: inject powerful
chemicals, charges, or energy toxic, can’t use with people around, don’t do gases and particles, are dangerous
3. Carbon filters: don’t do polar compounds, plug with particles, can catch fire
4. Thermal oxidizers: are dangerous, costly, can’t take sudden feed fluctuations
5. Chemical scrubbers: Cost money, use water, not reliable, can channel
6. Biological oxidizers: Technology of the future
Environmentally Friendly
Systems are proven to assist in reducing costly venting and air
exchange and saving energy in the process.
Reduce or eliminate harmful pollution
you are currently venting.
CWPCWP™™- Clean Water Plant may - Clean Water Plant may allow you to reuse some, or most allow you to reuse some, or most
of your waste process water.of your waste process water.
Save on water costs, conventional treatments and other
waste water disposal fees.
Technology will eliminate nuisance odor and hazardous problems including :
•Anatomy labs•Waste transfer and treatment plants•Diesel and gasoline fumes•Carbon Monoxide•Mold and other spores
•Paint fumes. (Paint will even dry faster!)•Particulates
•Hair and nail salon fumes•Volatile Organic Compounds (VOC’S)
•Automotive and Body Shops
•Many more!
Hospital Labs
Destroys up to 500 lbs of
pollution per day!
CAP™ 5000
Trash Transfer station.
Neighbor Complaints stopped soon after
installation.
Cage wash room at an animal lab to handle the
odors and bacteria
CAP600
Handling Tank Vent Emissions
Airborne material from Cage Wash
room captured
CAP85- Covers areas up to 2,000 sf
Destroys up to 10 lbs of pollution per
day
CAP600- Covers areas up to 5,000 sf with moderate
pollution levelsDestroys up to 60lbs of
pollution per day.
CWP1000Flow Rate: 50gpm
Destroys up to 100lbs of water pollution per day
Other water machine sizes
CWP175- 10 gpmCWP3000- 50-100 gpmCWP6000- 100-200 gpm
Custom systems for all applications are available
CWPModels
Benzene(ug/L)
Toluene(ug/L)
Ethylbenzene(ug/L)
Total xylenes(ug/L)
MTBE(ug/L)
Starting Concentration 220 300 150 570 27,000
CWP-4000 <0.5 (ND) <1.0 (ND) <1.0 (ND) <3.0 (ND) <1.0 (ND)
CWP-1000A <0.5 (ND) <1.0 (ND) <1.0 (ND) <3.0 (ND) <1.0 (ND)
CWP-1000B <0.5 (ND) <1.0 (ND) <1.0 (ND) <3.0 (ND) <1.0 (ND)
CWP-1000C <0.5 (ND) <1.0 (ND) <1.0 (ND) <3.0 (ND) <1.0 (ND)
ND = Not detectable
MTBE and BTEX-Contaminated Groundwater Cleaned
En
din
g C
on
cen
tra
tion
s
Property of Bio-Cascade, Inc. CONFIDENTIAL
Air (CAP90) and Water (CWP175) cleaning at contaminated site
Least Expensive, long term solution for Mold and Poor Air Quality
Problems
3rd Party Fungal Spore Test. NH town hall with chronic air quality problems
“Before” Test
Fungal Spores results after just 6 weeks of the CAP™ system operating.
Employee Complaints stopped
“After” Test
Complete Test Results are available upon request.