NCR RealPOS80c Release 1.2 Site Preparation Guide B00500001360 Issue C

description

NCR 7456 RealPOS80c Site Preparation Guide

Transcript of 7456 RealPOS80c SitePreparation Guide

NCR RealPOS™ 80c Release 1.2 

Site Preparation Guide 

 

B005‐0000‐1360 Issue C 

The product described in this book is a licensed product of NCR Corporation. 

NCR is a registered trademark of NCR Corporation. 

It is the policy of NCR Corporation (NCR) to improve products as new technology, components, software, and firmware become available. NCR, therefore, reserves the right to change specifications without prior notice. 

All features, functions, and operations described herein may not be marketed by NCR in all parts of the world. In some instances, photographs are of equipment prototypes. Therefore, before using this document, consult with your NCR representative or NCR office for information that is applicable and current. 

To maintain the quality of our publications, we need your comments on the accuracy, clarity, organization, and value of this book. 

Address correspondence to: 

Manger, Information Products  NCR Corporation 2651 Satellite Blvd. Duluth, GA  30096 

Copyright © 2002 By NCR Corporation Dayton, Ohio U.S.A. All Rights Reserved 

i

Preface

This is a contractual document. It contains important warnings and confers important legal rights and obligations. You are advised to read it carefully. 

It is the responsibility of the customer to ensure that all installation preparations are complete and in compliance with NCR specifications and requirements and all applicable national, state, or local codes, regulations, and laws. 

Safety Requirements

The NCR 7456 Terminal must be connected to an AC outlet that is near the terminal and is easily accessible by the operator. 

Warning: This unit contains hazardous voltages and should only be serviced by qualified service personnel. 

The on/off switch is a logic switch only. The AC line voltage primaries are live at all times when the power cord is connected. Therefore, disconnect the AC power cord before opening the unit to install features or service this terminal. 

Peripheral Usage The 7456 should be used only with peripheral devices that are recommended by NCR Corporation and are certified by the appropriate safety agency for the country of installation (UL, CSA, TUV, VDE). 

ii

About this Book

This book provides site preparation information for NCR 7456 Terminal components. Peripheral component and AC wiring site preparation information is NOT provided in this book. The associated reference documents are listed in the Related Site Preparation Data section. 

This book contains the information necessary for the preparation of a site conforming to the NCR specifications. It is very important that the site complies with the requirements specified in the document because, once the equipment has been installed, deficiencies in site preparation or the problems caused by these deficiencies are much more difficult to detect and correct. Further, failure to comply with these requirements or to take proper steps to protect equipment against risks identified in this document may cause serious damage to the equipment and to the customerʹs business. 

In addition to the need to comply with the requirements specified, electrical wiring, and mechanical systems must also comply with all relevant codes, laws, and regulations. 

It is important that the site be prepared by a customer or his agent who is fully conversant with the special requirements of electronic equipment. The responsibility of ensuring that the site is prepared in compliance with this document remains with the customer. 

For information and guidance purposes only, a list is provided, in general terms, of those matters for which the customer is responsible. This list is not intended to be comprehensive, and in no way modifies, alters, or limits the responsibility of the customer for all aspects of adequate site preparation. 

iii

NCR staff will be available to answer questions relating to the contents of this document except where: 

• a customer has been notified that a full or partial consultancy service is available and/or that NCR will be willing to undertake a preliminary or final site survey and 

• the customer shall have entered into a formal contract with NCR for provision of the same. 

No comment, suggestion, or advice offered or not offered about preparation of the site nor any inspection of the site whether before or after preparation is to be taken as approval of the location of the site and equipment or its preparation and NCR will not be liable in respect of any comment, suggestion, or advice given by its staff or in respect to any failure to give advice. 

Finally, only the customer can know the full extent of damage which may be caused to his business by reason of failure of the equipment which is to be installed. For this reason it is the customerʹs responsibility to ascertain the extent of any possible damage to his existing or planned business, and to effect full insurance in respect of it. 

iv

 

v

Table of Contents

Introduction  1

Related Site Preparation Documents  2

AC Power and Communications Wiring.............................................. 2 Peripherals ................................................................................................ 2 Where to Obtain Information Products ................................................ 3

Customer Responsibilities  4

AC Store Wiring Requirements  5

LAN Communications  5

System Configuration Diagrams  6

Handling System Components  7

Service Clearance Requirements  8

Operating Clearance Requirements  8

Component Dimensions  9

Integrated Configurations ...................................................................... 9 5942 LCD Operator Display............................................................. 9 5953 DynaKey .................................................................................. 11 9‐Inch CRT........................................................................................ 12

vi

Base Unit ................................................................................................. 12 Cash Drawers ......................................................................................... 13

NCR 2182 .......................................................................................... 13 NCR 2189 .......................................................................................... 13 NCR 2183 .......................................................................................... 14

Displays ................................................................................................... 15 7452‐K309 9‐Inch Monochrome CRT (497‐0418913).................... 15 7452‐K404 9‐Inch Monochrome CRT (497‐0418913).................... 16 7452‐K419 15‐Inch Monochrome CRT (497‐0414126).................. 17 5982 5‐Inch Monochrome LCD Operator Display....................... 18 5972/5973 2x20 Remote Customer Display on a Short Mount (VFD) .................................................................................... 19 5972‐1200 2x20 Remote Customer Display on a 16‐Inch Post (VFD) ........................................................................................ 20 5972‐1200 2x20 Remote Customer Display on a 8‐Inch Post (VFD) ................................................................................................. 21 5973 International VFD Remote Customer Display on a 16‐Inch Post ........................................................................................... 22 5973 International VFD Remote Customer Display on a 8‐Inch Post ........................................................................................... 23 5953 DynaKey .................................................................................. 24 5953‐K023 Table‐Top Mount.......................................................... 25 5964 w/Customer Display .............................................................. 28 Keyboards......................................................................................... 30 Printers.............................................................................................. 32

Component Weights.............................................................................. 35 Shipping Weight Estimate.............................................................. 36

Airflow Requirements ........................................................................... 37 Electrical Requirements......................................................................... 38

Peripheral Power Requirements ................................................... 38

vii

Cable Routing  39

System Cables  40

Printer Cables ......................................................................................... 40 Powered USB ................................................................................... 40 Powered USB (Power Only)........................................................... 40 RS‐232 (9‐Pin to 9‐Pin) .................................................................... 41 RS‐232 (9‐Pin to 25‐Pin) .................................................................. 41

Scanner Cables........................................................................................ 42 7872 or 7875 Scanner/Scale (RS‐232) ............................................. 42 7892 Scanner (Powered RS‐232) .................................................... 42 7882 Scanner (Powered RS‐232) .................................................... 43 7837 Scanner (Powered RS‐232) .................................................... 43

Display Cables........................................................................................ 44 VGA Display, Remote Extension, Mono...................................... 44 VGA Display, Color ........................................................................ 44 CRT AC Power Extension .............................................................. 45 5982 5‐Inch LCD .............................................................................. 45 5953 DynaKey .................................................................................. 45 5953 DynaKey w/Insert .................................................................. 46 5972 VFD Customer Display (Powered RS‐232) ......................... 46 5972 LCD Customer Display (Powered RS‐232) ......................... 47 Wedge Keyboard Y‐Cable.............................................................. 47 DVI to DVI........................................................................................ 48 Powered USB (12 V) for 5953......................................................... 48 12.1‐Inch LCD Power Cable........................................................... 48 PS/2 ‐ RS‐232 & Power .................................................................... 49 Wedge Keyboard Adapter ............................................................. 49

Cash Drawer Cables .............................................................................. 50

viii

Dual Cash Drawer, Y‐Cable........................................................... 50 Cash Drawer, Extension Cable ...................................................... 50

Communications Cable......................................................................... 51 Ethernet, 10/100BaseT..................................................................... 51

Keyboard Cables .................................................................................... 51 PS/2 Keyboard Extension ............................................................... 51 PS/2 Y‐Cable ..................................................................................... 52

Signature Capture/Electronic Payment Terminal Cable .................. 52 5945/5992 EPT (RS‐232 w/Power).................................................. 52

Power Cables .......................................................................................... 53 AC Power.......................................................................................... 53

Environmental Requirements  54

Barometric Pressure............................................................................... 54 Temperature ........................................................................................... 54 Humidity................................................................................................. 54

 

Revision Record

Issue Date Remarks

A  June 2002  First issue 

B  Apr 2003  Added 5973 International VFD Customer Display, 5952 10.4‐Inch DynaKey, 5953 12.1‐Inch USB DynaKey, 5942 Power Cable 

C  Sept 2003  Release 1.2 

NCR RealPOS 80c Site Preparation

Introduction This document provides the information necessary to prepare a site to NCR specifications prior to installing an NCR RealPOS 80c terminal (also referred to as the NCR 7456). The site must be properly prepared before the terminal is installed, because site preparation deficiencies may be difficult to detect and correct after installation. 

The NCR 7456 consists of separate pieces that may be combined in a variety of configurations. The System Configuration Diagram section identifies the individual components. Certain combinations are mutually exclusive. You must determine the equipment that will actually be installed before proceeding with the site preparation. 

2 NCR RealPOS 80c Terminal Site Preparation

Related Site Preparation Documents

AC Power and Communications Wiring Title Order Number

NCR Ethernet Communication Wiring Guide  BST0‐2118‐82 

NCR Terminal and Peripherals AC Wiring Guide  BST0‐2115‐53 

Peripherals Title Order Number

NCR 7194 Thermal Receipt Printer Ownerʹs Guide  B005‐0000‐1098 

NCR 5945 Electronic Payment Terminal User Manual 

B005‐0000‐1104 

NCR 5992 Signature Capture Terminal user Guide  B005‐0000‐1108 

NCR 5932 Keyboard Userʹs Guide  BD20‐1369‐A 

NCR 5942 12.1‐Inch LCD Monitor Userʹs Guide  B005‐0000‐1394 

NCR 5952 10.4 Inch Wedge DynaKey User’s Guide   BD20‐1370‐A 

NCR 5953 12.1 Inch DynaKey User Guide  B005‐0000‐1161 

NCR 5964 LCD Display Userʹs Guide  B005‐0000‐1324 

NCR 5972 2x20 Customer Display Userʹs Guide  BD20‐1372‐A 

NCR 5973 International VFD Customer Display User’s Guide 

B005‐0000‐1162 

NCR 5982 LCD Operator Display User Guide  BD20‐1443‐A 

NCR 7158 Thermal Receipt & Impact Slip Printer Owner’s Guide 

B005‐0000‐1112 

NCR 7197 Receipt Printer Owner’s Guide  B005‐0000‐1409 

NCR RealPOS 80c Terminal Site Preparation 3

Title Order Number

NCR 7162 Printer Setup & User’s Guide  BD20‐1453‐A 

NCR 7167 Two‐Station POS Printer Owner’s Guide  B005‐0000‐1406 

NCR 7875 Scanner/Scale Userʹs Guide  BD20‐1062‐A 

NCR 7872 Scanner/Scale User Guide  B005‐0000‐1179 

NCR 7882 Scanner User Guide  B005‐0000‐1305 

NCR 7892 Presentation Scanner User Guide  B005‐0000‐1179 

Where to Obtain Information Products

Information Products are available in electronic format from the following web sites. 

Web Sites • http://www.info.NCR.COM (World Wide Web) • http://inforetail.AtlantaGA.NCR.COM (NCR Intranet) 

4 NCR RealPOS 80c Terminal Site Preparation

Customer Responsibilities Before the system can be installed, the customer must perform or provide the following: 

• When required by NCR, provide the NCR Customer Services representative with appropriate drawings that indicate: • Equipment location • Site wiring (power and communications, paths and lengths) • Location of other equipment that may generate electrical noise, 

electromagnetic interference, or heat • Make building alterations necessary to meet wiring and other site 

requirements • Provide and install all communications cables, wall jacks, special 

connectors, and associated hardware • Provide and install necessary power distribution boxes, conduits, 

grounds, lightning protection devices, and associated hardware • Ensure all applicable codes, regulations, and laws (including, but 

not limited to, electrical, building, safety, and health) are met • Provide and install auxiliary power or other equipment as required • Provide storage or service areas as required • Meet all system/unit environmental requirements • Provide and install floor coverings and environment systems that 

limit or control static electricity build‐up and discharge  In general, keep the NCR equipment area free from dust, smoke, lint, and other particles. Restrict smoking, eating, and drinking around the equipment. Avoid locating the equipment near other machines that generate ink, carbon, and paper dust particles. 

NCR RealPOS 80c Terminal Site Preparation 5

AC Store Wiring Requirements The customer must provide suitable AC power for the terminals, associated equipment, and devices. A dedicated unswitched power line dedicated to the NCR equipment installation is recommended. Refer to the NCR Terminal and Peripherals AC Wiring Guide (BSTO‐2115‐53) for store AC wiring requirements. The AC outlet must be installed near the terminal and easily accessible to the operator. 

LAN Communications The NCR 7456 Terminal supports Ethernet 10/100baseT Local Area Network (LAN) communication protocol. For Ethernet communications wiring specifications, refer to the NCR Ethernet Communication Wiring Guide (BST0‐2118‐82). 

6 NCR RealPOS 80c Terminal Site Preparation

System Configuration Diagrams

5932 64-Key5932 Big Ticket

2182

2nd Drawer (Y-Cable)

2189

PS/2

19710a

RS-232 Peripherals

5972-1xxx/5973

5972-2xxx

LAN

5952/5953 Dynakey

PS/2 Keyboard

7837 7892

5964Touch Screen

PS/2 Keyboard

7837 7892 CRT

7875

7162

Motherboard

PCI LCD Card

Parallel

DVI VGA AC

7197

7167

5932 USB

USBDaughter

Card

USB(4/6)

Audio OutMic

71977167

RS-232(Powered)

5942

PS/2

Cash Drawer

RS-232RS-232

(Powered)

59925945

7892 7837

RS-232 Peripherals (Powered)

7882

RS-232(Powered)

5982

 

NCR RealPOS 80c Terminal Site Preparation 7

Handling System Components One person can move terminal system components. However, consider the following when moving the terminal or handling individual components. 

• Peripherals do not attach to the base unit and may slide off if the base unit is tipped. 

• The keyboard does not attach to the drawer unit and may slide off if the drawer unit is tipped. 

• Do not turn the CRTs or customer displays upside down while holding only the display mounting stand. The display is not attached to the stand and may slip out and be damaged if turned upside down. 

8 NCR RealPOS 80c Terminal Site Preparation

Service Clearance Requirements Device Above

mm (in.) Left Side mm (in.)

Right Side mm (in.)

Front mm (in.)

Behind mm (in.)

All Units  153 (6.0)  153 (6.0)  ‐  ‐  153 (6.0) 

Operating Clearance Requirements Device Above

mm (in.) Left Side mm (in.)

Right Side mm (in.)

Front mm (in.)

Behind mm (in.)

Terminal Base  ‐  100 (4.0)  ‐  100 (4.0)  100 (4.0) 

Keyboard  ‐  ‐  100 (4.0)  ‐  ‐ 

Cash Drawer  ‐  ‐  ‐  330 (13.0)  ‐ 

7158 Printer  325 (13.0)  300 (12.0)  ‐  100 (4.0)  25 (1.0) 

7162 Printer  325 (13.0)  300 (12.0)  ‐  100 (4.0)  25 (1.0) 

7167 Printer  305 (12)  305 (12)  ‐  ‐  ‐ 

7197 Printer  267 (10.5)  ‐  ‐  ‐   

5953 12.1‐inch DynaKey 

50 (2)  25 (1)  100 (4)  ‐  ‐ 

5964 12.1‐inch Touch LCD 

50 (2)  25 (1)  100 (4)  ‐  ‐ 

CRT Display  50 (2.0)  ‐  64 (2.5)  ‐  64 (2.5) 

15‐Inch CRT  50 (2.0)  150 (6.0)   150 (6.0)    50 (2.0) 

5972 2x20 Display  25 (1.0)  ‐  25 (1.0)  ‐  ‐ 

5982 5‐Inch LCD Display 

25 (1.0)  ‐  ‐  ‐  64 (2.5) 

 

NCR RealPOS 80c Terminal Site Preparation 9

Component Dimensions

Integrated Configurations The integrated displays are mounted on adjustable arms. In the illustrations following both the minimum and maximum width dimensions are shown. 

5942 LCD Operator Display

20734

480 mm(19.0 in.)

320 mm(12.6 in.)

320 mm(12.6 in.)

508 mm(20.0 in.)

 

10 NCR RealPOS 80c Terminal Site Preparation

5972 2x20 Customer Display

20735

500 mm(19.5 in.)

535 mm(21.0 in.)

187 mm(7.35 in.)

 

NCR RealPOS 80c Terminal Site Preparation 11

5953 DynaKey

20732

460 mm(18.25 in.)

320 mm(12.6 in.)

520 mm(20.5 in.)

670 mm(26.25 in.)

 

12 NCR RealPOS 80c Terminal Site Preparation

9-Inch CRT

20733

480 mm(19.0 in.)

320 mm(12.6 in.)

420 mm(16.5 in.)

480 mm(19.0 in.)

 

Base Unit

19715

401 mm(15.8 in.)

320 mm(12.6 in.)

108 mm(4.25 in.)

NCR RealPOS 80c Terminal Site Preparation 13

Cash Drawers

NCR 2182

15413

400 mm(15.75 in.)

108 mm(4.25 in.)

450 mm(17.7 in.)

Operating and Service Clearance for Drawer

254 mm(10.0 in.)

 

NCR 2189

20434

133 mm(5.25 in.)

527 mm(20.5 in.")

Operating and Service Clearance for Drawer

330 mm(13.0 in.)

464 mm(18.25 in.)

 

14 NCR RealPOS 80c Terminal Site Preparation

NCR 2183

18038

455 mm(17.9 in.)

108 mm(4.25 in.)

450 mm(17.7 in.)

Operating and Service Clearance for Drawer

263 mm(10.4 in.)

 

NCR RealPOS 80c Terminal Site Preparation 15

Displays

7452-K309 9-Inch Monochrome CRT (497-0418913)

19718

248 mm(9.75 in.)

240 mm(9.5 in.) 247 mm

(9.75 in.)

 

16 NCR RealPOS 80c Terminal Site Preparation

7452-K404 9-Inch Monochrome CRT (497-0418913)

14339

297 mm(11.7 in.)

240 mm(9.5 in.) 247 mm

(9.75 in.)

 

NCR RealPOS 80c Terminal Site Preparation 17

7452-K419 15-Inch Monochrome CRT (497-0414126)

17386

318 mm(12.5 in.)

361 mm(14.2 in.)

368 mm(14.5 in.)

381 mm(15 in.)

 

18 NCR RealPOS 80c Terminal Site Preparation

5982 5-Inch Monochrome LCD Operator Display

15411

140 mm(5.5 in.) 112 mm

(4.5 in)

165 mm(6.5 in.)

176 mm(6.9 in.) 16 mm

(0.7 in.)

128 mm(5 in.)

 

NCR RealPOS 80c Terminal Site Preparation 19

5972/5973 2x20 Remote Customer Display on a Short Mount (VFD)

17241

262 mm(10.3 in.)

162 mm(6.4 in.)

173 mm(6.8 in.)

119 mm(4.7 in.)

30 mm(1.2 in.)

178 mm(7.0 in.)

 

20 NCR RealPOS 80c Terminal Site Preparation

5972-1200 2x20 Remote Customer Display on a 16-Inch Post (VFD)

262 mm(10.3 in.)

1570895 mm

(3.75 in.)

561 mm(22.1 in.)

30 mm(1.2 in.)

119 mm(4.7 in.)

95 mm(3.75 in.)  

NCR RealPOS 80c Terminal Site Preparation 21

5972-1200 2x20 Remote Customer Display on a 8-Inch Post (VFD)

20131a

95 mm(3.75 in.)

356 mm(14.1 in.)

262 mm(10.3 in.)

119 mm(4.7 in.)

356 mm(14.1 in.)

30 mm(1.2 in.)

95 mm(3.75 in.)

 

22 NCR RealPOS 80c Terminal Site Preparation

5973 International VFD Remote Customer Display on a 16-Inch Post

262 mm(10.3 in.)

1570895 mm

(3.75 in.)

561 mm(22.1 in.)

30 mm(1.2 in.)

119 mm(4.7 in.)

95 mm(3.75 in.)  

NCR RealPOS 80c Terminal Site Preparation 23

5973 International VFD Remote Customer Display on a 8-Inch Post

20131a

95 mm(3.75 in.)

356 mm(14.1 in.)

262 mm(10.3 in.)

119 mm(4.7 in.)

356 mm(14.1 in.)

30 mm(1.2 in.)

95 mm(3.75 in.)

 

24 NCR RealPOS 80c Terminal Site Preparation

5953 DynaKey

20051

470 mm(18.5 in.)

300 mm(11.7 in.)

255 mm(10.0 in.)  

20052

470 mm(18.5 in.)

420 mm(16.5 in.)

366 mm(14.5 in.)

255 mm(10.0 in.)

263 mm(10.3 in.)

 

NCR RealPOS 80c Terminal Site Preparation 25

5953-K023 Table-Top Mount The Table‐Top Mount is fully adjustable between the minimum and maximum dimensions that are illustrated below. The DynaKey can also be rotated right and left of center (shown) by approximately 90 degrees, as well as tilted from a vertical position to approximately 45 degrees (shown). 

19909

213 mm(8.4 in.)

216 mm(8.5 in.)

400 mm(15.75 in.)

330 mm(13.0 in.)

370 mm(14.5 in.)

480 mm(19.0 in.)

38 mm1.5 in.

7.6.mm0.30 in.

70 mm2.75 in.

89 mm3.5 in.

114 mm4.25 in.

 

26 NCR RealPOS 80c Terminal Site Preparation

There are two positions to install the post to the back of the DynaKey. 

19908

270 mm(10.75 in.)

200 mm(8.0 in.)

105 mm4.13 in.

140 mm5.5 in.

 

NCR RealPOS 80c Terminal Site Preparation 27

5964 12.1-Inch Touch LCD

19555

(348 mm)13.7 in.

(252 mm)9.9 in.

(297 mm)11.7 in.

 

Tilt/Swivel Dimensions

20305

Swivel Angle88.0

Swivel Angle88.0

Hinge Tilt Angle87.6

 

28 NCR RealPOS 80c Terminal Site Preparation

5964 w/Customer Display

19557

12.9 in.(328 mm)

13.7 in.(348 mm)

16.6 in.(42.2mm)

 

NCR RealPOS 80c Terminal Site Preparation 29

5942 12.1-Inch LCD Monitor

19810

306 mm(12.0 in.)

304 mm(11.9 in.)

190 mm(7.5 in.)

133 mm(5.25 in.)

165 mm(6.5 in.)

47 mm(1.9 in.)

13 mm(0.5 in.)

 

30 NCR RealPOS 80c Terminal Site Preparation

Keyboards

5932 Big Ticket POS Keyboard

11412

179 mm(7 in.)

20 mm(.8 in.)

455 mm(17.9 in.)

45 mm(1.75 in.)

 

5932 64-Key POS Keyboard

11413

184 mm(7.2 in.)

335 mm(13.2 in.)

42 mm(1.7 in.)  

NCR RealPOS 80c Terminal Site Preparation 31

5932 USB Big Ticket POS Keyboard

19716

184 mm(7.2 in.)

455 mm(17.9 in.) 42 mm

(1.7 in.)

 

32 NCR RealPOS 80c Terminal Site Preparation

Printers

7158 Thermal Receipt and Impact Slip Printer

305 mm(12.0 in.)

165 mm(6.5 in.)

336 mm(13.25 in) 229 mm

(9.0 in)17307

7162 Dot Matrix Slip Printer

15410

250 mm(11.7 in.)

297 mm(11.7 in.)

191 mm(7.5 in.)

142 mm(5.6 in.)

 

NCR RealPOS 80c Terminal Site Preparation 33

7167 Thermal Receipt and Impact Slip Printer

19711b

190 mm(7.5 in.)

174 mm(7.0 in.)

262 mm(10.3 in.)

316 mm(12.5 in.)

275 mm10.8 in.

 

7194 Thermal Receipt Printer

19712c

146 mm(7.75 in.)

156 mm(6.25 in.)

184 mm(7.25 in.)

255 mm10.1 in.

 

34 NCR RealPOS 80c Terminal Site Preparation

7197 Thermal Receipt Printer

19712c

146 mm(7.75 in.)

156 mm(6.25 in.)

184 mm(7.25 in.)

Top Cover Open256 mm(10.1 in.)

 

NCR RealPOS 80c Terminal Site Preparation 35

Component Weights

Terminal Component Weight kg (lbs.)

Base unit w/Batteries  10.7  (23.5) 

Base unit w/o Batteries  8.8  (19.3) 

Integrated Base; w/o Peripherals, w/Batteries  13.0  (35.0) 

Integrated Base; w/o Peripherals, w/o Batteries  10.7  (28.8.) 

2182 Cash drawer  6.2  (13.7) 

2183 Cash drawer  11.4  (25.15) 

2189 Cash drawer  9.5  (20.9) 

64‐Key keyboard  0.9  (1.9) 

Big ticket POS keyboard  1.4  (3) 

9‐Inch CRT Display  4.3  (9.4) 

15‐Inch CRT Display  11.9  (26.5) 

5982 5‐Inch LCD Display  0.8  (1.8) 

5972‐1000 Customer display  0.7  (1.5) 

5972‐2300 Customer display  0.7  (1.5) 

5973 International VFD Customer Display   0.7  (1.5) 

Display mounting stand  4.3  (9.5) 

5953 DynaKey module  3.4  (7.5) 

5942 12.1‐Inch LCD Monitor  2.8  (6.2) 

5964 12.1‐Inch Touch LCD  4.7  (10.4) 

7167 Receipt/Impact Printer  4.5  (10.0) 

36 NCR RealPOS 80c Terminal Site Preparation

Terminal Component Weight kg (lbs.)

7197 Thermal Receipt Printer  1.5  (3.4) 

7158 Printer (with MICR and check flip)  4.9  (10.8) 

7162 Printer  5.8  (12.7) 

7194 Thermal receipt printer  1.4  (3) 

Flex disk drive and data cables  0.4  (0.9) 

3.5‐Inch Hard disk drive (20 GB) with mount  0.5  (1.0)  

Shipping Weight Estimate To obtain the total maximum weight of a specific configuration, add the weights of the appropriate individual components. The following table provides an example. 

Terminal Component Weight kg (lbs.)

Integrated Base unit w/Batteries  13.0  (35.0) 

5942 12.1‐Inch LCD Monitor  2.8  (6.2) 

5972‐1xxx Customer display  0.7  (1.5) 

64‐Key keyboard  0.9  (1.9) 

7167 Receipt/Impact Printer  4.5  (10.0) 

     

Total  21.9  (5460) 

Miscellaneous items and shipping materials  5.2  (11.5) 

     

Shipping total  27.1  (66.1)  

NCR RealPOS 80c Terminal Site Preparation 37

Airflow Requirements Do not block the air vents on the terminal or peripherals. These vents are necessary for cooling. 

19717  Do not place the terminal in an enclosed area where sufficient ventilation is not available. Leave at least 100 mm (4 inches) of clearance on sides where air vents are located. 

38 NCR RealPOS 80c Terminal Site Preparation

Electrical Requirements The terminalʹs power cord plugs into the back of the terminal and into a three‐wire, single‐phase, 120 or 240 VAC receptacle. The available power cords are described in the System Cables section.  

The terminalʹs internal power supply has a maximum output of 237 Watts and provides power to the terminal, one printer, and peripherals. Additionally, an AC power socket is available on the back of the terminal for a CRT. 

Maximum Terminal Power Usage

120 Volt System 240 Volt System

Voltage Range  90 ‐ 136 VAC  180 ‐ 265 VAC 

Frequency  50/60 Hz  50/60 Hz 

Current  4.6 Amps  2.3 Amps  

 

Peripheral Power Requirements The number of peripherals that the terminal can support is dependent upon which peripherals are connected. For planning purposes, use the RealPOS 80c Power Matrix (B005‐0000‐1526) to calculate the power requirements for your specific system configuration. 

Note: This file requires Microsoft Excel to run. 

NCR RealPOS 80c Terminal Site Preparation 39

Cable Routing Cable connectors are located in the back of the Base Unit.  

Mic Audio Out

E D C B A 24VRS232/C RS232/D

RS232/A RS232/B VGA DVI-1 Parallel LAN PS/2

19531

* RS232/A RS232/B

* RS232/C * RS232/D

VGA DVI-1 Parallel LAN PS/2

12V USB 24V USB Cash DrawerAC Input Accessory AC Mic Audio Out

* Powered Serial Port  

40 NCR RealPOS 80c Terminal Site Preparation

System Cables

Printer Cables Powered USB

USB (Printer)24V USB+(Terminal)Power (Printer)

19307

Access Hole Diameters

497-0424888 - 1 m(1416-C713-0010)

497-0424501 - 4 m(1416-C713-0040)

23.0 mm(0.9 in.)

19.0 mm(0.75 in.)

 

Powered USB (Power Only)

19721

24V USB+(Terminal)

Power(Printer)

497-0424887 - 1m1416-C712-0010

497-0422292 - 4m1416-C712-0040

Access Hole Diameters 23.0 mm(0.9 in.)

19.0 mm(0.75 in.)

 

NCR RealPOS 80c Terminal Site Preparation 41

RS-232 (9-Pin to 9-Pin)

19722

9-pinD-shell

Receptacle

9-pinD-shell

Receptacle

497-0408349 - 0.7 m(1416-C359-0007)

497-0407943 - 4 m(1416-C266-0040)

RS-232(Printer)

RS-232(Terminal)

Access Hole Diameters 38.0 mm(1.5 in.)

38.0 mm(1.5 in.)

 

RS-232 (9-Pin to 25-Pin)

20127a

9-pinD-shell

Receptacle

25-pinD-shell

Plug

497-0407427 - 1.0 m(1416-C337-0010)

497-0407429 - 4 m(1416-C337-0040)

RS-232(Printer)

RS-232(Terminal)

63.5 mm(2.5 in.)

Access Hole Diameters38 mm(1.5 in.)

 

42 NCR RealPOS 80c Terminal Site Preparation

Scanner Cables

7872 or 7875 Scanner/Scale (RS-232)

15479

RS-232(Scanner)

D-Shell9-Pin

Receptacle

Modular10-PinPlug

497-0300422 - 4 m(1416-C019-0040)

RS-232(Terminal)

Access Hole Diameters 19.0 mm(0.75 in.)

38.0 mm(1.5 in.)

 

7892 Scanner (Powered RS-232)

20450

Scanner

D-Shell9-Pin

Receptacle

Modular10-PinPlug

497-0425593 - 3.0 m(1416-C643-0030)

RS-232(Terminal)

Access Hole Diameters 32.0 mm(1.25 in.)

38.0 mm(1.5 in.)

 

NCR RealPOS 80c Terminal Site Preparation 43

7882 Scanner (Powered RS-232)

19728

Scanner

D-Shell9-Pin

Receptacle

Modular10-PinPlug

497-0419723 - 4.0 m(1416-C653-0040)

RS-232(Terminal)

Access Hole Diameters 19.0 mm(0.75 in.)

38.0 mm(1.5 in.)

 

7837 Scanner (Powered RS-232)

19724

Scanner

D-Shell9-Pin

Receptacle

Modular10-PinPlug

497-0412952 - 2.5 m(1416-C430-0025)

RS-232(Terminal)

Access Hole Diameters 19.0 mm(0.75 in.)

38.0 mm(1.5 in.)

 

44 NCR RealPOS 80c Terminal Site Preparation

Display Cables

VGA Display, Remote Extension, Mono

14607

VGA(CRT Display)

Sub Miniature D-Shell15-PinPlug

497-0008164 - 4 m1416-C042-0040

Sub Miniature D-Shell15-Pin

Receptacle

VGA(Terminal)

Access Hole Diameters 38.0 mm(1.5 in.)

38.0 mm(1.5 in.)

 

VGA Display, Color

16318

VGA(CRT Display)

VGA(Terminal)

Access Hole Diameters 38.0 mm(1.5 in.)

38.0 mm(1.5 in.)

Sub Miniature D-Shell15-Pin Plug

Sub Miniature D-Shell15-Pin Receptacle

497-0428080 1416-C840-00101.0 m Black1.5 m Black1.0 m

White1.5 mWhite

497-0428068 1416-C839-0015497-0424530 1416-C753-0015497-0424531 1416-C754-0010

 

NCR RealPOS 80c Terminal Site Preparation 45

CRT AC Power Extension

19741

497-0406237 - 4m(1416-C508-0040)

Access Hole Diameters 45.0 mm(1.75 in.)

45.0 mm(1.75 in.)

 

5982 5-Inch LCD

19731

LCD(PCI Card)

5982

497-0409750 - 4mChamp50-pin Plug

24-pinMinifit Plug

Access Hole Diameters 44.0 mm(1.75 in.)

57.0 mm(2.25 in.)

 

5953 DynaKey

19847

5953

50-pinAmplimite

Plug

50-pinAmplimite

Plug

497-0414885 - 1 m(1416-C482-0010)

497-0413878 - 4 m(1416-C482-0040)

LCD(PCI Card)

Access Hole Diameters 57.0 mm(2.25 in.)

57.0 mm(2.25 in.)

 

46 NCR RealPOS 80c Terminal Site Preparation

5953 DynaKey w/Insert

19846

5953

50-pinAmplimite

Plug

50-pinAmplimite

Plug

LCD(PCI Card)

497-0419053 - 1 m(1416-C647-0010)

497-0419054 - 4 m(1416-C647-0040)

Access Hole Diameters 57.0 mm(2.25 in.)

57.0 mm(2.25 in.)

 

5972 VFD Customer Display (Powered RS-232)

20279a

CustomerDisplay

TerminalRS-232 Port

497-0420926 - 1 m1416-C683-0010

497-0420927 - 4 m1416-C683-0040

9-pinD-Shell

Receptacle

24-PositionMicrofit

Receptacle

25.4 mm(1.0 in.)

Access Hole Diameters

35 mm(1.5 in.)

 

NCR RealPOS 80c Terminal Site Preparation 47

5972 LCD Customer Display (Powered RS-232)

20281a

9-pinD-shell

Receptacle

12-PositionMicrofit

Receptacle

CustomerDisplay

RS-232(Terminal)

497-0420928 - 1.0 m(1416-C684-0010)

497-0420929 - 4.0 m(1416-C684-0040)

25.4 mm(1.0 in.)

Access Hole Diameters

35 mm(1.5 in.)

 

Wedge Keyboard Y-Cable

19733

497-0407490 - 0.5 m(1416-C338-0005)

RS-232(Terminal)

Kybd(Terminal)

6-pinMini-DINPlug

5-pinMini-DINPlug

9-pinD-shellReceptacle

PS/2(PCI LCD Card)

Access Hole Diameters 19.0 mm(0.75 in.)

38.0 mm(1.5 in.)

 

48 NCR RealPOS 80c Terminal Site Preparation

DVI to DVI

19725

63.5 mm(2.5 in.)Access Hole Diameters

497-0422831 - 1.0 m(1416-C723-0010)

497-0422832 - 4.0 m(1416-C723-0040)

63.5 mm(2.5 in.)

24-PinDVI-D Plug

24-PinDVI-D Plug

DVI(Terminal)

DVI(Display)

 

Powered USB (12 V) for 5953

20059

497-0424838 - 1.0 m(1416-C757-0010)

497-0424839 - 4.0 m(1416-C757-0040)

Powered USB(5953)

Powered USB(Terminal)

 

12.1-Inch LCD Power Cable

20444

Power(Display)

497-0426160 - 4 m (White)1416-C803-0040

497-0428512 - 4 m (Black)1416-C803-0040 USB

Powered USB(Terminal)

NCR RealPOS 80c Terminal Site Preparation 49

PS/2 - RS-232 & Power

497-0422833 - 1m(1416-C725-0010)

497-04222834 - 4m(1416-C725-0040)

19734

RS-232(Terminal)

PS/2(Terminal)

12 V COM(5964)

Access Hole Diameters 38.0 mm(1.5 in.)

38.0 mm(1.5 in.)

 

Wedge Keyboard Adapter

19735

497-0406868

PS/2(Terminal)

6-pinMini-DIN

Plug

5-pinMini-DIN

PlugLCD

(PCI Card)

Access Hole Diameters 19.0 mm(0.75 in.)

19.0 mm(0.75 in.)

 

50 NCR RealPOS 80c Terminal Site Preparation

Cash Drawer Cables

Dual Cash Drawer, Y-Cable

15808

497-0409394 - 0.6 m(1416-C372-0006)

CashDWR. #1

CashDWR. #2

Cash Drawer(Terminal/Printer)

Access Hole Diameters 51.0 mm(2.0 in.)

16.0 mm(0.63 in.)

 

Cash Drawer, Extension Cable

19730

230-0145735 - 3.0 m(1424-C112-0030)

Cash Drawer(Terminal/Printer)

Cash Drawer(Cable)

Modular6-Pin Jack

Modular 6-Pin Plug

Access Hole Diameters 30.0 mm(1.2 in.)

16.0 mm(0.63 in.)

 

NCR RealPOS 80c Terminal Site Preparation 51

Communications Cable

Ethernet, 10/100BaseT

16298

Modular8-PinPlug

Modular8-PinPlug

497-0008905 - 3.0 m(1416-C059-0030)

Access Hole Diameters 19.0 mm(0.75 in.)

19.0 mm(0.75 in.)

 

Keyboard Cables

PS/2 Keyboard Extension

15403

PS/2(Keyboard)

PS/2(Terminal)

6-pinMini-DIN

Plug

6-pinMini-DIN

Receptacle

497-0406056 - 1.8 m(1416-C281-0018)

Access Hole Diameters 19.0 mm(0.75 in.)

19.0 mm(0.75 in.)

 

52 NCR RealPOS 80c Terminal Site Preparation

PS/2 Y-Cable

17894a

PS/2(Mouse)

PS/2(Terminal)

6-pinMini-DIN

Plug

6-pinMini-DIN

Receptacle

PS/2(Keyboard)

5-pinMini-DIN

Receptacle

51 mm(2 in.)

497-0414489 - 0.2 m1416-C542-0002)

 

Signature Capture/Electronic Payment Terminal Cable

5945/5992 EPT (RS-232 w/Power)

19723

63.5 mm(2.5 in.)

19 mm(0.75 in.) Access Hole Diameters

497-0418406 - 4.0 m(1416-C634-0040) 9-pin

D-shellReceptacle

RS-232(EFT Unit)

RS-232(Terminal)

9-pinMini-DIN

Plug

 

NCR RealPOS 80c Terminal Site Preparation 53

Power Cables

AC Power

15405

45 mm(1.75 in.)Access Hole Diameter

Terminal

006-1009037 - U.S.

The following power cables (not shown)also have an IEC connection of 45 mm: 006-8601001 - Japan Twist-Lock 006-8601010 - International 006-8601011 - SEV 006-8601012 - U.K. 006-8601019 - Australia

 

54 NCR RealPOS 80c Terminal Site Preparation

Environmental Requirements Barometric Pressure

The terminal operates within the following barometric pressure conditions: 

• Maximum operating altitude: 3,000 m (9,843 ft.) • Operating range of pressure: 105 to 69 kPa (15.2 to 10.0 lb./in.) 

Temperature The terminal operates over the temperature ranges shown below. Continuous operation must be avoided at or near the indicated temperature extremes or in locations where the temperature changes beyond the restrictions. 

Temperature Parameter Restriction

Operating  5°C to 45°C (41°F to 113°F), dry bulb 

Storage  ‐10°C to 50°C (14°F to 122°F), three months 

Shipping  ‐40°C to 60°C (‐40°F to 140°F), one week 

Dew Point  26°C (79°F) maximum 

Humidity The terminal operates within the humidity ranges shown below. Continuous operation must be avoided at or near the indicated humidity extremes or in locations where the humidity changes beyond the restrictions. Never expose the terminal to condensation. 

Humidity Type Restriction

Relative  10% to 90% 

Maximum change rate  10%/60 minutes 

Storage  10% to 90% relative humidity, three months 

Shipping  5% to 95% relative humidity, one week  

Appendix A: Transient Protection

AC Power Line Transient Protection

In the process of power distribution, transient electrical energy (including, but not limited to, lightning strikes, intermittent short circuits, and switching transients) can be introduced onto power lines. Such transient energy can be very damaging to electronic hardware, and can also cause data corruption. Under these circumstances, NCR recommends the use of AC power transient suppressors. Such protection devices are intended to guard against power line transients that can result in hardware damage and various system or program errors. 

Improvement of any deficiencies in power quality is a customer responsibility. Malfunction and/or component failure as a result of power quality problems are/is not covered by the NCR Maintenance Agreement. NCR accepts no liability for any such occurrence nor for its consequences. 

When power transient suppression is required, the suppressors used should meet the following minimum requirements: 

• Dissipate energy to match the appropriate application categories as defined by IEEE Standard 587. 

• Be of the voltage limiting (clipping), or tracking filter type. The suppressor must not clamp the voltage to zero, and must self‐recover after the passage of the transient. The suppressor may be of the hybrid type construction that makes use of various technologies in order to meet speed and dissipation requirements. 

A-2 Appendix A: Transient Protection

• Upon failure, exhibit a positive indication of its failure such as a blown fuse or tripped breaker. 

• Be listed by the accepted safety organization for the country involved (UL, CSA, VDE, ETL, and so on) and the installation must conform to local, state, and national electrical codes and regulations. 

Data Line Transient Protection The nature of the transient phenomenon may extend to the data communication lines connected to this equipment. It is the responsibility of the customer to install and connect a data line transient suppression system to correct or prevent any deficiencies. Such systems must meet the following minimum requirements: 

• Be of the voltage limiting type and must self‐recover after passage of the transient. 

• Insert less than 5 ohms resistance and minimal inductive and capacitive loading at the operating frequency for data lines, in order to avoid signal degradation. 

• Be installed in accordance with all applicable local, state, and national electrical codes and regulation. 

Note: In certain countries, NCR is able to supply both power and data line transient suppressors as well as a comprehensive line of power conditioning equipment. For application data, contact your NCR Customer Services Division Representative.