7409-K312 Fixed Angle Mount Image Scanner Kit Instructions Issue A

Transcript of 7409-K312 Fixed Angle Mount Image ScannerMS 4980 Imaging Scanner 006-8615166 MS4980 Imaging Scanner...

Page 1: 7409-K312 Fixed Angle Mount Image ScannerMS 4980 Imaging Scanner 006-8615166 MS4980 Imaging Scanner Cable 497-0472847 Screw, 6-32 x 1/4, Phillips, PH 006-8611016 Filler Plate 497-0471591

7409-K312

Fixed Angle Mount Image Scanner Kit Instructions

Issue A

Page 2: 7409-K312 Fixed Angle Mount Image ScannerMS 4980 Imaging Scanner 006-8615166 MS4980 Imaging Scanner Cable 497-0472847 Screw, 6-32 x 1/4, Phillips, PH 006-8611016 Filler Plate 497-0471591

Revision Record Issue Date Remarks

A July 2011 First issue

Page 3: 7409-K312 Fixed Angle Mount Image ScannerMS 4980 Imaging Scanner 006-8615166 MS4980 Imaging Scanner Cable 497-0472847 Screw, 6-32 x 1/4, Phillips, PH 006-8611016 Filler Plate 497-0471591

1

Introduction This kit provides an Imaging Scanner for the following terminals.

NCR RealPOS 25 (7610)

NCR RealPOS 50 (7611)

The assembly installs on the front of the 7409-K035 Fixed Angle Mount.

29813

MS 4980 Imaging Scanner006-8615166

MS4980 Imaging Scanner Cable497-0472847

Screw, 6-32 x 1/4, Phillips, PH006-8611016

Filler Plate497-0471591

Scanner Bracket795-0164700

Page 4: 7409-K312 Fixed Angle Mount Image ScannerMS 4980 Imaging Scanner 006-8615166 MS4980 Imaging Scanner Cable 497-0472847 Screw, 6-32 x 1/4, Phillips, PH 006-8611016 Filler Plate 497-0471591

2

Installation Procedures 1. Remove the screws (2) in the sides of the Fixed Angle Mount.

Hex Screw(One Each Side)

2. Rest the bottom of the display on the Display Support.

Display Support

Page 5: 7409-K312 Fixed Angle Mount Image ScannerMS 4980 Imaging Scanner 006-8615166 MS4980 Imaging Scanner Cable 497-0472847 Screw, 6-32 x 1/4, Phillips, PH 006-8611016 Filler Plate 497-0471591

3

3. Remove the Blank Faceplate from the Fixed Angle Mount (2 screws).

Blank Faceplate

4. Hook the bottom of the Fixed Angle Mount Faceplate and Image Scanner Assembly onto

the bottom edge of the opening on the front of the Fixed Angle Mount and secure it with screws (2).

Fixed Angle Mount Faceplate

Page 6: 7409-K312 Fixed Angle Mount Image ScannerMS 4980 Imaging Scanner 006-8615166 MS4980 Imaging Scanner Cable 497-0472847 Screw, 6-32 x 1/4, Phillips, PH 006-8611016 Filler Plate 497-0471591

4

5. Remove the Cable Cover from the terminal and connect the cables to the terminal I/O Panel.

a. Connect the scanner serial cable to an RS-232 Connector.

Warning: The Imaging Scanner is a 5 Vdc device. Make sure the serial port is set to 5 V. See following pages for port settings.

b. Connect the scanner USB cable to a USB Connector.

USB AUSB B RS232/CRS232/A RS232/B

Page 7: 7409-K312 Fixed Angle Mount Image ScannerMS 4980 Imaging Scanner 006-8615166 MS4980 Imaging Scanner Cable 497-0472847 Screw, 6-32 x 1/4, Phillips, PH 006-8611016 Filler Plate 497-0471591

5

7610 Serial Port Jumper Settings

28687a

* Default setting

COMD

COMCCOMA

COMB

Ring Indicator12 V

5 V

* Default setting

Ring Indicator12 V

5 V

Page 8: 7409-K312 Fixed Angle Mount Image ScannerMS 4980 Imaging Scanner 006-8615166 MS4980 Imaging Scanner Cable 497-0472847 Screw, 6-32 x 1/4, Phillips, PH 006-8611016 Filler Plate 497-0471591

6

7611 Serial Port Jumper Settings

28764

COMCCOMB

COMA

COMD

* Default setting

Ring Indicator12 V

5 V

* Default settingRing Indicator

12 V5 V

Page 9: 7409-K312 Fixed Angle Mount Image ScannerMS 4980 Imaging Scanner 006-8615166 MS4980 Imaging Scanner Cable 497-0472847 Screw, 6-32 x 1/4, Phillips, PH 006-8611016 Filler Plate 497-0471591

7

6. Close the Cable Cover.

7. Close the Display onto the Fixed Angle Mount and secure it with screws (2).

Hex Screw(One Each Side)