6800G boosters

5
file no: 100.14 date: february 2015 supersedes: 100.14 date: february 2014 compliant with wras, acs & dvgw solution outline 6800G boosters

Transcript of 6800G boosters

Page 1: 6800G boosters

file no: 100.14date: february 2015

supersedes: 100.14date: february 2014tm

compliant with wras, acs & dvgw

s o l u t i o n o u t l i n e

6800G boosters

Page 2: 6800G boosters

b

a

43

10

11

discharge connection grooved standard on 6" & 8"

suctionconnectiongrooved standard on 6" & 8"

1

5

2 611

c max

he

g

d

f

j

9 87

b

a

43

10

11

discharge connection grooved standard on 6" & 8"

suctionconnectiongrooved standard on 6" & 8"

1

5

2 611

c max

he

g

d

f

j

9 87

b

a

43

10

11

discharge connection grooved standard on 6" & 8"

suctionconnectiongrooved standard on 6" & 8"

1

5

2 611

c max

he

g

d

f

j

9 87

A rmstrong Design Envelope boosters address the water

delivery challenges presented by high-rise buildings by com-bining high-efficiency Vertical Multistage pumps with modern variable speed controls.

Optimal energy savings Design Envelope control curves are programmed into the controller.

Easy installation and replacement No additional wiring or mounting is required on-site and indi-vidual pumps can be removed and replaced as a complete unit.

Single source of supply Armstrong supports all aspects of the booster system package.

Integrated controls and advanced mechanical and digital capabilities Armstrong Design Envelope boosters integrate pumping components and advanced digital controllers for:

Armstrong Design Envelope solutions are sized using a pre-set collection of the most efficient sizes for a range of performance levels, so they can easily adapt to changes in design, site or operating conditions. Over the life of your building, the Design Envelope approach to selection protects you against potentially costly and time-consuming system rework due to:

at 50% design flow

up to

70% energy savings

the challenge

design envelope value

kWh

zz

zzzz

zz

zz

zz

zz

zz

zz

zz

zz

zz

4:00midnight 4:008:00 noon 8:00

25

0

50

75

100 water demand capacity ( in %)

Stable flow and pressure for every activity throughout your day

Embedded control logic ensures optimum efficiency at all times, adjusting pump speed and staging pumps on and off as needed during periods of high and low demand.

Changes to fixtures

Changes to building design

Installation of backflow preventer

Pipe corrosion and scaling

the need for energy savings has led to broad acceptance of variable speed tech-nology for use with booster systems.

However, the inclusion of digital controllers adds complexity to the sizing, installation, commissioning and operation of boosters. Lacking an integrated

approach to solution design and selection, booster solutions that are contractor-friendly and owner-friendly are hard to find. Designers are left to guess at required capacity, contractors struggle with installation and building owners are often left with a booster that fails to deliver on promised benefits.

Page 3: 6800G boosters

76.001930.40

1.0025.40

3.5088.90max

5.00127.00

13 4

7

7

8

see note 6

on

36.00914.4050.131273.18

max

notes:

1 - dimensions are based on factory choice standard components. for other than standard consult factory, as a new drawing may be required.

2 - all dimensions are in inches [mm].

3 - tolerances are +/- 1/4" [6.35] unless otherwise specified.

4 - drawings are for layout purposes only.

5 - drawing 2502-000 is applicable for pumps with suction size up to 3", 30hp @ 3600rpm, and nominal impeller diameters of 10". for larger sizes consult factory for new drawing.

6 - booster is supplied with standard groove for header connections suitable for optional victaulic type or equivalent flanges (optionally supplied loose).

maximum system pressure: 175 psi 250 psi

connection orientation

suction left hand - std. as shown right hand

discharge

left hand - std. as shown right hand

do not scale

revisions

zonerev.descriptiondateapproved

original release, see e.o. #1036885/13/10

header size 3" ips pipe 304 s.s. 4" ips pipe 304 s.s. 6" ips pipe 304 s.s.

1 pump, motor, & drive6 base & panel support2 suction connection7 pressure gauges3 discharge connection8 check valves4 control panel5 isolation valves

d

c

b

a

b

c

d

1 2 3 4 5 6 7 8

8764321

e

f

e

f

sheet 1 of 1

unless otherwise specified:

scale: 1:1

rev dwg. no.

csize

title:

name

comments:

q.a.

mfg appr.

eng appr.

checked

drawn

finish

material

application

used on next assy

proprietary and confidential

do not scale

jmc

dwb

s.a. armstrong

5/13/10

2502-000

6732/3ivs - triplex

date

asme y14.5-1994

5

dimensions are in inchesweight in pounds

tolerances:fractional1/4angular: mach0.5 bend0.5two place decimal 0.25three place decimal 0.250

dimensioning and tolerancing per: the information contained in thisdrawing is the sole property ofs.a. armstrong. any reproduction in part or as a wholewithout the written permission ofs.a. armstrong is prohibited.

a

weight: design authority:third angleprojection

76.001930.40

1.0025.40

3.5088.90max

5.00127.00

13 4

7

7

8

see note 6

on

36.00914.4050.131273.18

max

notes:

1 - dimensions are based on factory choice standard components. for other than standard consult factory, as a new drawing may be required.

2 - all dimensions are in inches [mm].

3 - tolerances are +/- 1/4" [6.35] unless otherwise specified.

4 - drawings are for layout purposes only.

5 - drawing 2502-000 is applicable for pumps with suction size up to 3", 30hp @ 3600rpm, and nominal impeller diameters of 10". for larger sizes consult factory for new drawing.

6 - booster is supplied with standard groove for header connections suitable for optional victaulic type or equivalent flanges (optionally supplied loose).

maximum system pressure: 175 psi 250 psi

connection orientation

suction left hand - std. as shown right hand

discharge

left hand - std. as shown right hand

do not scale

revisions

zonerev.descriptiondateapproved

original release, see e.o. #1036885/13/10

header size 3" ips pipe 304 s.s. 4" ips pipe 304 s.s. 6" ips pipe 304 s.s.

1 pump, motor, & drive6 base & panel support2 suction connection7 pressure gauges3 discharge connection8 check valves4 control panel5 isolation valves

d

c

b

a

b

c

d

1 2 3 4 5 6 7 8

8764321

e

f

e

f

sheet 1 of 1

unless otherwise specified:

scale: 1:1

rev dwg. no.

csize

title:

name

comments:

q.a.

mfg appr.

eng appr.

checked

drawn

finish

material

application

used on next assy

proprietary and confidential

do not scale

jmc

dwb

s.a. armstrong

5/13/10

2502-000

6732/3ivs - triplex

date

asme y14.5-1994

5

dimensions are in inchesweight in pounds

tolerances:fractional1/4angular: mach0.5 bend0.5two place decimal 0.25three place decimal 0.250

dimensioning and tolerancing per: the information contained in thisdrawing is the sole property ofs.a. armstrong. any reproduction in part or as a wholewithout the written permission ofs.a. armstrong is prohibited.

a

weight: design authority:third angleprojection

key benefits

key features

Selection software: allows users to select products, and engage in collaborative system design over the internet.Visit https://aceonline.armlink.com/newdefault.asp

Interchangeable inlet sides: on models with flanged connections, installing contractors can adjust the suction and discharge inlet orientation by moving end caps to accommodate site conditions.

roi calculator: displays your savings and roi based on real data from your installation. Visit https://roi.armlink.com/

contractor friendly

Armstrong offers easy-to-use selection tools for performance analysis and product selection.easy bms

connectivitySupports leading communications protocols, including Modbus/BACnet mstp/BACnet ip.

lower energy costs

Design Envelope boosters stage individual pumps on and off for optimum efficiency and reduced energy costs. Boosters also adjust setpoint according to flow to save energy.

minimal footprint

Armstrong Design Envelope boosters lead the industry with a compact package design that minimizes floor space requirements and sim-plifies on-site delivery.

space savings of 25%

baseframe allows easy lifting and installation

Design Envelope 6800G Competing models68"× 40" 77"× 48"

easy commissioning

Single step interface to enable/disable pressure setback and apply a 24-hour timer for an easy inspection process.

76.00 1930.40

1.00 25.40

3.50 88.90max

5.00 127.00

1 34

7

7

8

see note 6

on

36.00 914.4050.13 1273.18

max

notes:

1 - dimensions are based on factory choice standard components. for other than standard consult factory, as a new drawing may be required.

2 - all dimensions are in inches [mm].

3 - tolerances are +/- 1/4" [6.35] unless otherwise specified.

4 - drawings are for layout purposes only.

5 - drawing 2502-000 is applicable for pumps with suction size up to 3", 30hp @ 3600rpm, and nominal impeller diameters of 10". for larger sizes consult factory for new drawing.

6 - booster is supplied with standard groove for header connections suitable for optional victaulic type or equivalent flanges (optionally supplied loose).

maximum system pressure: 175 psi 250 psi

connection orientation

suction

left hand - std. as shown right hand

discharge

left hand - std. as shown right hand

do not scale

revisions

zone rev. description date approved

original release, see e.o. #103688 5/13/10

header size 3" ips pipe 304 s.s. 4" ips pipe 304 s.s. 6" ips pipe 304 s.s.

1 pump, motor, & drive 6 base & panel support2 suction connection 7 pressure gauges3 discharge connection 8 check valves4 control panel5 isolation valves

d

c

b

a

b

c

d

12345678

8 7 6 4 3 2 1

e

f

e

f

sheet 1 of 1

unless otherwise specified:

scale: 1:1

revdwg. no.

csize

title:

name

comments:

q.a.

mfg appr.

eng appr.

checked

drawn

finish

material

application

used onnext assy

proprietary and confidential

do not scale

jmc

dwb

s.a. armstrong

5/13/10

2502-000

6732/3ivs - triplex

date

asme y14.5-1994

5

dimensions are in inchesweight in pounds

tolerances:fractional 1/4angular: mach 0.5 bend 0.5two place decimal 0.25three place decimal 0.250

dimensioning and tolerancing per:the information contained in thisdrawing is the sole property ofs.a. armstrong . any reproduction in part or as a wholewithout the written permission ofs.a. armstrong is prohibited.

a

weight: design authority:third angleprojection

intuitive interface

3.4-inch alphanumeric touchscreen with 16mb flash memory supports multi-languages.

industry- leading software capabilities

Page 4: 6800G boosters

Energy profiling capabilities include:

Monthly/yearly kWh consumption reporting

Instantaneous kW readings

Data storage reset capability

Detailed data charts illustrating energy consumption patterns

Flow Estimation includes:

Maximum flow

Current flow

Data charts

energy & water consumption data

Armstrong Design Envelope boost-ers provide data storage and detailed reports on booster operation.

softfill Allows building managers to recharge the system with water after maintenance with no risk of damage to system components.

wras approval requires that a water fitting should not cause waste, misuse, undue consumption or contamination of the water supply and must be ‘of an appropriate quality and standard’.

Allows users to select different operating setpoints for different seasons through the interface (hmi) screen.

alternate set points

extended warranty

76.00 1930.40

1.00 25.40

3.50 88.90max

5.00 127.00

1 34

7

7

8

see note 6

on

36.00 914.4050.13 1273.18

max

notes:

1 - dimensions are based on factory choice standard components. for other than standard consult factory, as a new drawing may be required.

2 - all dimensions are in inches [mm].

3 - tolerances are +/- 1/4" [6.35] unless otherwise specified.

4 - drawings are for layout purposes only.

5 - drawing 2502-000 is applicable for pumps with suction size up to 3", 30hp @ 3600rpm, and nominal impeller diameters of 10". for larger sizes consult factory for new drawing.

6 - booster is supplied with standard groove for header connections suitable for optional victaulic type or equivalent flanges (optionally supplied loose).

maximum system pressure: 175 psi 250 psi

connection orientation

suction

left hand - std. as shown right hand

discharge

left hand - std. as shown right hand

do not scale

revisions

zone rev. description date approved

original release, see e.o. #103688 5/13/10

header size 3" ips pipe 304 s.s. 4" ips pipe 304 s.s. 6" ips pipe 304 s.s.

1 pump, motor, & drive 6 base & panel support2 suction connection 7 pressure gauges3 discharge connection 8 check valves4 control panel5 isolation valves

d

c

b

a

b

c

d

12345678

8 7 6 4 3 2 1

e

f

e

f

sheet 1 of 1

unless otherwise specified:

scale: 1:1

revdwg. no.

csize

title:

name

comments:

q.a.

mfg appr.

eng appr.

checked

drawn

finish

material

application

used onnext assy

proprietary and confidential

do not scale

jmc

dwb

s.a. armstrong

5/13/10

2502-000

6732/3ivs - triplex

date

asme y14.5-1994

5

dimensions are in inchesweight in pounds

tolerances:fractional 1/4angular: mach 0.5 bend 0.5two place decimal 0.25three place decimal 0.250

dimensioning and tolerancing per:the information contained in thisdrawing is the sole property ofs.a. armstrong . any reproduction in part or as a wholewithout the written permission ofs.a. armstrong is prohibited.

a

weight: design authority:third angleprojection

service contact screens

Stores and presents contact information for maintenance and service personnel.

b

a

43

10

11

discharge connection grooved standard on 6" & 8"

suctionconnectiongrooved standard on 6" & 8"

1

5

2 611

c max

he

g

d

f

j

9 87

All Armstrong Design Envelope pumps and booster systems are supported by an industry-leading 2-year warranty

Pressure setback Built-in logic that adjusts pressure setpoint proportional to flow to account for lower friction losses and lower flows. This is an alternative to installing a remote sensor.

No-flow shutdown Senses when there is no demand in the system and puts the booster in sleep mode.

No-flow pressure optimizationThe system generates an additional boost of pressure prior to shutdown, allowing the use of a smaller draw-down tank.

compliant with industry

association codes

two years

Page 5: 6800G boosters

booster application range

Systems can be flexibly combined in 2 to 5 pumps

Options available:• Overhead break tank • anti-vibration kit

tm

E

D

C

GH (TYP)

4

798

3

FB

Ø.471210 HOLES OF

A

ØJ

2

15

MAINISOLATOR

SWITCH

6

5

23

45

flow rate pressure

total

performance 6800g 2 - 5 units

320 max m3/h 16 max Bar 120 max kW

b a n g a l o r e

+91 (0) 80 4906 3555

m a n c h e s t e r

+44 (0) 8444 145 145

b u f f a l o

+1 716 693 8813

t o r o n t o

+1 416 755 2291

s h a n g h a i

+86 21 3756 6696

b i r m i n g h a m

+44 (0) 8444 145 145

For more information, contact your Armstrong representative or visit us at:ArmstrongFluidTechnology.com/ContactUs

a r m s t r o n g f lu i d t ec h n o lo g y. co ma r m s t r o n g f lu i d t ec h n o lo g y established 1934

s ã o p a u l o

+55 11 4781 5500