631

84
SREE DATTHA INSTITUTE OF ENGINEERING AND SCIENCES DEPARTMENT OF ELECTRONICS AND COMMUNICATION ENGINEERING

Transcript of 631

Page 1: 631

SREE DATTHA INSTITUTE OF ENGINEERING AND SCIENCES

DEPARTMENT OF ELECTRONICS AND COMMUNICATION ENGINEERING

Page 2: 631

PROJECT REPORT ON OFC LINK DESIGN FOR SDH SYSTEM OF STM -16

By:

B.SOURAV (09E41A0465) A.SAHITHI (09E41A0473)

S.PRATYUSHA (09E41A04A7) T.SNEHITHA (09E41A0486)

Page 3: 631

OUTLINE OF PROJECT

• OVERVIEW OF FIBRE OPTICS TRANSMISSION SYSTEM

• PLESIOCHRONOUS DIGITAL HIERARCHY(PDH) • SYNCHRONOUS DIGITAL HEIRARCHY (SDH)• STM-16 DESCRIPTION• E1 CONNECTION CONFIGURATION• OTDR TESTING

Page 4: 631

OVERVIEW OF FIBRE OPTICS TRANSMISSION SYSTEM

Page 5: 631

PRESENTATION OUTLINE• Introduction• Designing a Fiber Optic System • Principle of operation of OFC • Types of OF cables• Optical fiber parameters • Advantages of optical fiber • Applications of optical fiber

Page 6: 631

INTRODUCTION

• An optical fiber is a flexible, transparent fiber made of a pure glass (silica) not much thicker than a human hair. It functions as a waveguide, or “light pipe”, to transmit light between the two ends of the fiber.

Page 7: 631

• Optical fibers typically include a transparent core surrounded by a transparent cladding material with a lower index of refraction.Light is kept in the core by total internal reflection.

Fig 1: Basic structure of OFC

Page 8: 631

Fig 2: Cross Section details

Page 9: 631

Designing

Fig 3 : Design of optical fiber system

Page 10: 631

Fig 4: Major elements of an optical fiber link

Page 11: 631

Principle of operation of OFC

Total internal reflection: “If the angle of incidence increases amore than the critical angle, the light is totally reflected back into the first material so that it does not enter the second material. The angle of incidence and reflection are equal and it is called Total Internal Reflection.”

Page 12: 631

Fig 5: Total internal reflection in an OFC

Page 13: 631

Types of OF cables

• Single Mode Fibre

• Multi Mode Fibre

1. Step index

2. Graded index

Page 14: 631

Fig 6: Different types of Fibers.

Page 15: 631

OPTICAL FIBRE PARAMETERS

• Wavelength• Frequency • Window • Attenuation • Dispersion• Bandwidth • Numerical Aperture

Page 16: 631

ADVANTAGES OF OPTICAL FIBER

• Wide bandwidth• Low loss• Electromagnetic immunity• Small size• Light weight• Greater safety• Higher security

Page 17: 631

Fig 7: Loss vs frequency curve

Page 18: 631

APPLICATIONS OF OPTICAL FIBER • Local area networks operating at high speeds or over

large areas, and backbone systems connecting slower local area networks.

• Transmission of signals within the ships/aircraft/automobiles.

• Moderate speed transmission of computer data in places where fibers is most economical to install.

• Link among computers and high-resolution video terminals used for such as computer aided design.

• Connection between telephone network and antennas for mobile telephone service

• Long haul telecommunication systems on land and at sea to carry many simultaneous telephone calls over long distances

Page 19: 631

Plesiochronous Digital Hierarchy

Page 20: 631

PRESENTATION OUTLINE

• INTRODUCTION

• VERSIONS OF PDH

• LIMITATIONS OF PDH

Page 21: 631

INTRODUCTION

• The term “PLESIOCHRONOUS” is derived from Greek plesio which means near, and chronous, time.

• It means, networks works in different state but not perfectly within network.

• Transmission and reception are synchronized but timing is not• The channel clocks derived from diff master clock and range is

within limit . It called “PLESIOCHRONOUS” SIGNAL.• PDH signal are neither SYNCHRONOUS nor ASYNCHRONOUS

Page 22: 631

VERSIONS OF PDH

There are two version in PDH namely

• THE EUROPEAN.

• THE AMERICAN.

EUROPEAN = 30 CHANNELS.

AMERICAN = 24 CHANNELS.

Page 23: 631

Fig 8: Plesiochronous Digital Hierarchy

Page 24: 631

Fig 9: Plesiochronous Digital Hierarchy

Page 25: 631

LIMITATIONS OF PDH NETWORK

• Homogeneity of equipment

• Limited functionality

• The problem of channel segregation

• The problem of cross-connection of channels

• Incompatibility

Page 26: 631

SYNCHRONOUS DIGITAL HIERARCHY(SDH)

Page 27: 631

INTRODUCTION

• SONET (Synchronous Optical Network) or SDH (Synchronous Digital Hierarchy) as it's known in Europe, is a set of standards for interfacing Operating Telephone Company (OTC) optical networks.

• They are a set of global standards for interfacing equipment from different vendors (One of the few where telephony is concerned).

Page 28: 631

PDH PRINCIPLE

Page 29: 631

SDH PRINCIPLE

Page 30: 631

SDH Advantages versus PDH

The advantage of SDH over PDH are

• SDH is based on the principal of direct synchronous multiplexing.

• Essentially, separate, slower signals can be multiplexed directly onto higher speed SDH signals without intermediate stages of multiplexing.

• SDH is more flexible than PDH and provides advanced network management and maintenance features.

Page 31: 631

BIT RATES

Fig 10. International organization defined standardized bit rates

Page 32: 631

SDH FRAME REPRESENTATION

Page 33: 631

SDH FRAME REPRESENTATION

• Everywhere in the world, the standard SDH frame representation is a MATRIX with 9 rows and with variable columns.

Page 34: 631

SDH FRAME REPRESENTATION

Page 35: 631
Page 36: 631

SDH MULTIPLEXING

Page 37: 631

STM FRAMES

Page 38: 631

SDH EQUIPMENTS1. TERMINAL MULTIPLEXER

2. REGENERATOR

Page 39: 631

3. TRANSPONDER (LAMDA CONVERTER)

4. ADD/DROP MULTIPLEXER

Page 40: 631

5. DIGITAL CROSS CONNECT

Page 41: 631

NETWORK TOPOLOGIES

Page 42: 631

NETWORK PROTECTION

• Protection can be given in 2 ways

1. Ring protection

2. 1:1 protection

3. 1:N protection

Fig 11: Ring protection

Page 43: 631

Fig 12: 1:1 Protection

Fig 13: 1:N Protection

Page 44: 631

QUALITY PARAMETER

• Errored Seconds (ES) Seconds during which there is at least one error per block or frame

• Severely Errored Seconds (SES) Length of time during which a major alarm (LOS, LOF, AIS, Etc.) is recorded or when 30% of the frames received in one second contain errors

• Unavailability Length of time where SONET equipment is not available (beginning after 10 consecutive SES)

Page 45: 631

STM-16 DESCRIPTION

Page 46: 631

Fig 14: STM-16 Practical Equipment

Page 47: 631

Different slots of STM-16

• COM 01 CARD• AGG06 CARD• ELAN05D CARD• 2 XCC05 CARD• 2 XCEXT CARD• 2 A010000 CARD• FAN• MFC3 CARD• POWER DSITRIBUTION MODULE

Page 48: 631
Page 49: 631

E1 CONNECTION CONFIGURATION

Page 50: 631

STEPS TO BE FOLLOWED

1. Connect the PC to NMS interface of the network element.

2. Log in to an uncommissioned network element requisites.

Page 51: 631
Page 52: 631
Page 53: 631
Page 54: 631
Page 55: 631
Page 56: 631
Page 57: 631
Page 58: 631
Page 59: 631
Page 60: 631
Page 61: 631
Page 62: 631
Page 63: 631

Designing a Fiber Optic System The following step-by-step procedure should be followed when

designing any system.• Determine the correct optical transmitter and receiver

combination based upon the signal to be transmitted.• Determine the operating power available • Determine the special modifications (if any) necessary (such as

impedances, bandwidths, special connectors, special fiber size, etc.).

• Calculate the total optical loss (in dB) in the system by adding the cable loss, splice loss, and connector loss. These parameters should be available from the manufacturer of the electronics and fiber.

• Compare the loss figure obtained with the allowable optical loss budget of the receiver.

• Check that the fiber bandwidth is adequate to pass the signal desired.

Page 64: 631

Calculation of receiver sensitivity

• We make use of DTA for calculation.

• DTA has transmitter to send the signal to STM-16 and receiver the same.

• It compare both this signal and indicates if there is any errors.

Page 65: 631
Page 66: 631
Page 67: 631
Page 68: 631
Page 69: 631
Page 70: 631
Page 71: 631
Page 72: 631
Page 73: 631

S.No Tx power (dbm)

Rx power (dbm)

attenuation Error status

1 . -0.11 -7.88 -7.99 NO

2. -0.11 -12 -12.11 NO

3. -0.11 -15 -15.11 NO

4. -0.11 -20 -20.11 NO

5. -0.11 -24 -24.14 NO

6. -0.11 -29 -29.20 NO

7. -0.11 -33.8 -33.19 NO

8. -0.11 -34.7 -34.18 NO

9. -0.11 -99 -99.11 YES

Table 1: Receiver sensitivity of station A

Page 74: 631

Receiver sensitivity of station A

• Transmitted power = -0.11dbm

• Minimum receiver power = -34.7dbm

• Transmitted overload = -12dbm (from overload sheet).

• Hence dynamic range = 12>Rx>34.7

Page 75: 631

S.No Tx power Rx power attenuation Error status

1. -2.8 -4.19 -6.99 NO

2. -2.8 -10.2 -16 NO

3. -2.8 -19.9 -22 NO

4. -2.8 -22.7 -25.5 NO

5. -2.8 -23.2 -26 NO

6. -2.8 -99 -101.8 YES

Table 2: Receiver sensitivity of station A

Page 76: 631

• Transmitted power = -2.8dbm

• Minimum receiver power = -23.2dbm

• Transmitted overload = -4.10dbm (from overload sheet).

• Hence dynamic range = 4.10>Rx>23.2

Receiver sensitivity of station B

Page 77: 631

OTDR TESTING

Page 78: 631

INTRODUCTION

• Optical Time Domain Reflectometer (OTDR) is used for system troubleshooting, verification documentation has always been an important step of the system installation process.

REASONS TO USE OTDR :

1. Product acceptance.

2. Troubleshooting.

3. System verification.

4. Documentation.

Page 79: 631

OTDR PRINCIPLE

• An OTDR takes advantage of the backscattered light that occurs in all fibers as light travels down the core

Fig 15: Backscattered light (Rayleigh scattering)

Page 80: 631

CALCULATION OF CABLE LENGTH USING OTDR

Fig 16: Correction Factor Calculation

Page 81: 631

LINK BUDGET

• Definition: Computation of all losses that comes into account from source node to destination node is called “LINK BUDGET”.

• Lets see how to prepare link budget of 2 station (seperated by 100 Kms) connected through of cable.

Page 82: 631

Numeric values for the link: Tx power = 0.11dbm (calculated)

Rx sensitivity (stn A) = -34.07dbm (calculated)

Rx sensitivity (stn B) = -23.2dbm (calculated)

Source fiber coupling = 3db

Connector loss = 1db

Splice loss = 0.5db per slice

Fiber loss = 0.5db per km

Power margin = 0.11- (-23.2) = 23.31db

Calculation of various losses:

Splice loss (50 slices) = 0.1 x 50 = 5db

Fiber loss (100Km) = 0.25 x 100 = 25db

Total loss = 3+2+5+25 =35db

System loss margin = power margin – total loss

= -11.69

Page 83: 631

Maximum distance between 2 station

Dynamic range between stn A and stn B = Tx power of stn A – Rx sensitivity of stn B

= 0.11-(-23.2) = 23.31

Connector loss =1dbm

System loss margin = -11.69

Max loss b/w 2 station = 23.31+1-11.69

= 12.62

We know that there is a loss of 0.5 db per Km (1310 nm)

Hence max distance between 2 station = 12.62/0.5

= 25.24 Km

= 25 Km (approx)

Page 84: 631

CONCLUSION

• We have successfully created an link between two STM-16 systems.By this we can say that compared to other STM-N systems.

• STM-16 has very high speed 2.5 Gbps.

• By using OFC cables we have transmitted the frames between two STM-16 systems and calculated receiver sensitivity using analyzer practically.