6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 –...

34
06/23/22 SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW

Transcript of 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 –...

Page 1: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

04/18/23SYSTEMS LEVEL DESIGN REVIEW 1

HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR

MSD1 – P12453SYSTEMS LEVEL DESIGN REVIEW

Page 2: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

AGENDA

04/18/23SYSTEMS LEVEL DESIGN REVIEW 2

• Team and Project Member Introduction (1 min.)

• Project Introduction (4 min.)

• Customer Needs (5 min.)

• Concept Generation (15 min)

• Concept Selection (25 min)

• Risk Management (10 min)

• Next Steps (10 min)

• Q&A (10 min)

Page 3: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

TEAM AND PROJECT MEMBERS

04/18/23SYSTEMS LEVEL DESIGN REVIEW 3

TEAM:Project Manager: Markus Holzenkamp (ME)Project Engineers: Cody Anderson (ME)

Robin Leili-Marrazzo (ME)

CUSTOMER:Dr. Jason Kolodziej, ME Department, RITDr. Edward Hensel, ME Department, RIT

SUPPORT:Project Guide: Bill Nowak (Xerox)Faculty Champion: Dr. Kolodziej (RIT)Sponsors: Scott Delmotte (D-R)

James Sorokes (D-R) Britt Dinsdale (D-R)

Page 4: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

PROJECT INTRODUCTION

Reciprocating compressors

Previous work

Project scope

04/18/23SYSTEMS LEVEL DESIGN REVIEW 4

Page 5: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

Reciprocating compressorsReciprocating compressors use the back and forth motion of a piston connected to a crankshaft to compress the working fluid. In the case of this project we are working a single cylinder dual-action air compressor

04/18/23SYSTEMS LEVEL DESIGN REVIEW 5

Page 6: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

Previous workThis project is a continuation of P11452. The group installed the Dresser-Rand compressor and the first basic sensors for monitoring beginning of life characteristics

04/18/23SYSTEMS LEVEL DESIGN REVIEW 6

Page 7: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

P12453 PROJECT SCOPE

04/18/23SYSTEMS LEVEL DESIGN REVIEW 7

• Understand the current state of the compressor

• Current sensors, DAQ capabilities

• Operation characteristics of reciprocating compressors

• Install and run ENVISION Condition monitoring system to be donated by Dresser-Rand

• Increase the current DAQ capabilities

• End Goal: Design, develop, and install effective health monitoring capabilities

Page 8: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

CUSTOMER NEEDS

Table of prioritized customer needs

Function diagram

04/18/23SYSTEMS LEVEL DESIGN REVIEW 8

Page 9: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

TABLE OF PRIORITIZED CUSTOMER NEEDS

04/18/23SYSTEMS LEVEL DESIGN REVIEW 9

Priority Need

1 Learn RITDAQ capabilities and propose and implement improvements in code to generate p-v diagrams, time and frequency plots

1 Propose and install possible additional sensors to measure stage pressures, stage temperature, bearing temperature (low priority)

2 Install Envision System

3 Select, install, and integrate Encoder

99 Develop future undergrad/grad labs

Page 10: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

RITDAQ ENCODER

LABS

Program Envision

Install main bearing sensor

MeasurePressureTempAccel

Measure accel

Understand currentcapabilities

Program RITDAQ

Measure Velocity

Choose an Encoder

Mount Encoder

Program Encoder

Measure Crank Angle

ENVISION

Consider Ergonomics

Mount Envision

Install add.sensors

Validate RITDAQresults

Validate Envision Results

Generate p-v diagrams

Concepts needed

Assistance from D-R

FUNCTION DIAGRAM

Page 11: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

CONCEPT GENERATION & SELECTION

Engineering specs: Encoder/Envision

House of Quality / Pareto of engineering specs

Pugh concept selection

Additional sensors

04/18/23SYSTEMS LEVEL DESIGN REVIEW 11

Page 12: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

ENGINEERING SPECIFICATIONS - ENCODER

04/18/23SYSTEMS LEVEL DESIGN REVIEW 12

Page 13: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

ENGINEERING SPECS - ENVISION

04/18/23SYSTEMS LEVEL DESIGN REVIEW 13

Page 14: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

HOUSE OF QUALITY

04/18/23SYSTEMS LEVEL DESIGN REVIEW 14

Page 15: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

PARETO OF ENGINEERING SPECS VS NEEDS

04/18/23SYSTEMS LEVEL DESIGN REVIEW 15

Page 16: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

PRIORITIZED ENGINEERING SPECS

04/18/23SYSTEMS LEVEL DESIGN REVIEW 16

Page 17: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

PUGH CONCEPT SELECTION FOR ENCODER

04/18/23SYSTEMS LEVEL DESIGN REVIEW 17

Page 18: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

POSSIBLE LOCATIONS FOR ENCODER

04/18/23SYSTEMS LEVEL DESIGN REVIEW 18

Page 19: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

ENCODER

04/18/23SYSTEMS LEVEL DESIGN REVIEW 19

Side Diameter

Flywheel 2.720 in

Oil Pump 0.495 in

Shaft Dimensions

Page 20: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

PUGH CONCEPT SELECTION FOR ENVISION

04/18/23SYSTEMS LEVEL DESIGN REVIEW 20

Page 21: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

POSSIBLE LOCATIONS FOR ENVISION

04/18/23SYSTEMS LEVEL DESIGN REVIEW 21

Page 22: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

ADDITIONAL SENSOR TABLE

04/18/23SYSTEMS LEVEL DESIGN REVIEW 22

Page 23: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

POSSIBLE LOCATIONS FOR ADDITIONAL SENSORS

04/18/23SYSTEMS LEVEL DESIGN REVIEW 23

Page 24: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

POSSIBLE LOCATIONS FOR ADDITIONAL SENSORS

04/18/23SYSTEMS LEVEL DESIGN REVIEW 24

S11, S12S11, S12

S2S2

S13, S14S13, S14

Page 25: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

POSSIBLE LOCATIONS FOR ADDITIONAL SENSORS

04/18/23SYSTEMS LEVEL DESIGN REVIEW 25

S6S6 S7, S8S7, S8

S4,S5S4,S5

S9, S10S9, S10

S3S3

Page 26: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

RISK MANAGEMENT

04/18/23SYSTEMS LEVEL DESIGN REVIEW 26

Page 27: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

04/18/23SYSTEMS LEVEL DESIGN REVIEW 27

Page 28: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

04/18/23SYSTEMS LEVEL DESIGN REVIEW 28

Page 29: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

04/18/23SYSTEMS LEVEL DESIGN REVIEW 29

Page 30: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

TOP RISKS

04/18/23SYSTEMS LEVEL DESIGN REVIEW 30

• Trip Hazard from wires

• Potential for injury

• Risk to equipment

• Noise in sensor signal

• Cannot use data

• Delay in equipment deliveries

• Project falls behind schedule

Page 31: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

NEXT STEPS

MSD 1 Schedule

Detail Design Enabling Action Items

04/18/23SYSTEMS LEVEL DESIGN REVIEW 31

Page 32: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

MSD 1 SCHEDULE

04/18/23SYSTEMS LEVEL DESIGN REVIEW 32

Page 33: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

DETAILED DESIGN ENABLING ACTION ITEMS

04/18/23SYSTEMS LEVEL DESIGN REVIEW 33

• Markus:

• Select encoder (type, make, model, specs)

• Robin:

• Become familiar with Envision software (how to develop screens, add functionality)

Cody:

Consult with Dresser-Rand on how to best install sensors (sensor type, sensor location)

Page 34: 6/10/2015SYSTEMS LEVEL DESIGN REVIEW 1 HEALTH-MONITORING OF A RECIPROCATING COMPRESSOR MSD1 – P12453 SYSTEMS LEVEL DESIGN REVIEW.

Q&A

04/18/23SYSTEMS LEVEL DESIGN REVIEW 34