6 Navigation principle D-55 / D-55h / D-75 / D-75t …...ISOM D Display & Remote Alarm Single point...

2
ISOM D Display & Remote Alarm Single point remote alarm ISOM D-15 h 4729 0200 (*) (*) h -> for medical locations (**) t -> tropicalized & reinforced against vibrations and shocks Multi point display ISOM Digiware D-55 4729 0203 Multi point display & embedded webserver ISOM Digiware D-75 4729 0205 ISOM Digiware D-75t 4729 0206 (**) Multi point display ISOM Digiware D-55h 4729 0204 (*) www.socomec.com Full user manual: www.socomec.com/operating-instructions 546782B 7 6 Menu Structure (HOME) D-55h D-55 / D-75 / D-75t LOADS LIST OF DEVICES X X MEASURES ISOM X X ISOM INSULATION X X TREND 24H X X TREND Rf X X TREND Cf X INJECTION CONTROL X X MEASUREMENTS X X FEEDERS X X INPUTS / OUTPUTS DIGITAL INPUTS X X DIGITAL OUTPUTS X X ANALOG INPUTS X X EVENTS IN PROGRESS X X HISTORY X X PARAMETERS DISPLAY LANGUAGE X X DATE FORMAT X X RS485 COM X X ETHERNET COM X X SET REMOTE DEVICE DATE / TIME X X CHANGE PASSWORD X X CONFIGURE A DEVICE X X AUTODETECT SERIAL DEVICES X X LIST PRODUCTS X X ADD NEW DEVICE X X REMOVE DEVICE X X RESTORE A PRODUCT FACTORY SETTINGS X X PRODUCT SOFT VERSION X X ABOUT IP & MAC adresses, SN, Soft version X X Navigation principle D-55 / D-55h / D-75 / D-75t INSULATION (+T°C > & I > FOR D-55h) QUICK-ACCESS TRENDS LOCATION F-60 DEVICE MENU CIRCUIT INSULATIONS EVENTS ISOM IMD OK ... LANGUAGE COMMUNICATION OK ISOM IMD PARAMETERS ... 1 2 Dimensions (mm) Mounting 5 60 80 STEP 1 STEP 2 1 2 21 0.83 0.20 2.36 3.15 2.36 60 3.15 80 TOP BOTTOM 3.88 98.5 1.22 0.63 Max 0.03 31 16 Max 0.8 3.88 98.5 3.62 +0.03 92 +0.8 - 0 - 0 3.62 +0.03 92 +0.8

Transcript of 6 Navigation principle D-55 / D-55h / D-75 / D-75t …...ISOM D Display & Remote Alarm Single point...

Page 1: 6 Navigation principle D-55 / D-55h / D-75 / D-75t …...ISOM D Display & Remote Alarm Single point remote alarm ISOM D-15 h 4729 0200 (*) (*) h -> for medical locations (**) t ->

ISOM DDisplay & Remote Alarm

Single point remote alarmISOM D-15 h 4729 0200 (*)

(*) h -> for medical locations(**) t -> tropicalized & reinforced

against vibrations and shocks

Multi point display ISOM Digiware D-55 4729 0203

Multi point display & embedded webserver ISOM Digiware D-75 4729 0205

ISOM Digiware D-75t 4729 0206 (**)

Multi point display ISOM Digiware D-55h 4729 0204 (*)

www.socomec.com

Full user manual:

www.socomec.com/operating-instructions

546782B

7

6

Menu Structure (HOME)

D-55h D-55 / D-75 / D-75tLOADS LIST OF DEVICES X XMEASURES ISOM X XISOM INSULATION X X

TREND 24H X XTREND Rf X XTREND Cf XINJECTION CONTROL X XMEASUREMENTS X XFEEDERS X X

INPUTS / OUTPUTS DIGITAL INPUTS X XDIGITAL OUTPUTS X XANALOG INPUTS X X

EVENTS IN PROGRESS X XHISTORY X X

PARAMETERS DISPLAY LANGUAGE X XDATE FORMAT X XRS485 COM X XETHERNET COM X XSET REMOTE DEVICE DATE / TIME

X X

CHANGE PASSWORD X XCONFIGURE A DEVICE X XAUTODETECT SERIAL DEVICES X XLIST PRODUCTS X XADD NEW DEVICE X XREMOVE DEVICE X XRESTORE A PRODUCT FACTORY SETTINGS X XPRODUCT SOFT VERSION X X

ABOUT IP & MAC adresses, SN, Soft version X X

CORPORATE HQ CONTACT: SOCOMEC SAS, 1-4 RUE DE WESTHOUSE, 67235 BENFELD, FRANCE. Non contractual document

Navigation principle D-55 / D-55h / D-75 / D-75t

INSULATION(+T°C > & I > FOR D-55h)

QUICK-ACCESS

TRENDS LOCATION F-60 DEVICE MENU

CIRCUIT INSULATIONS

EVENTSISOM IMD

OK

...

LANGUAGE

COMMUNICATION

OKISOM IMDPARAMETERS

...

1

2

Dimensions (mm)

Mounting

560

80

STEP 1 STEP 2

1

2

21

0.83

0.202.36

3.15

2.36

60 3.15

80

TOP

BOTTOM

3.88

98.5

1.22

0.63 Max 0.03

31

16 Max 0.83.8898.5

3.62

+0.

03

92 +

0.8

- 0- 0

3.62 +0.03

92 +0.8

Page 2: 6 Navigation principle D-55 / D-55h / D-75 / D-75t …...ISOM D Display & Remote Alarm Single point remote alarm ISOM D-15 h 4729 0200 (*) (*) h -> for medical locations (**) t ->

3

4

D-55 / D-55h / D-75 / D-75t

D-15h

5

6

Technical Characteristics

Operating

NC

RS

485

LIYCY-CY

MASTER

Sup

ply

24V

DC

(30 W max)Protection 2A gG

DIG

IWAR

EET

HERN

ET

ETHERNET

DIGIWARE BUS!

DIG

IWAR

ED

IGIW

ARE

DIGIWARE BUS!

DIGIWARE BUS!

ISOM D-15h ISOM D-55h ISOM D-55 ISOM D-75 / D-75tMechanical characteristicsButtons Capacity touch technologyScreen resolution 350 x 160 pixelsType Single device connection Multi device connectionEthernet RJ45 10/100 Mbs (use a shielded Ethernet cable)

- Gateway Modbus TCPBacnet IP

SNMP

Gateway Modbus TCPBacnet IP

SNMP

Gatewat Modbus TCPBACnet IP

SNMPEmbedded Webserver

Webview MConnectable devices number Max 3 Max 32RJ45 Digiware input (2x) input (1x)RS485 2-3 wires - MasterSpeed 115200 bdsMicro-USB - Diagnostic

DimensionsExternal dimensions 3.15 x 3.15 in

80 x 80 mm3.88 x 3.88 in

98.5 x 98.5 mmDoor cut - 3.62+0.03 x 3.62+0.03 in

92+0.8 x 92+0.8 mm

Depth 1.02 in 26 mm

1.85 in 47 mm

Electronical characteristicsSupply Via Digiware 20.4 ... 27.6 VDC, Class 2 - 20 W maxSupply protection Via Digiware integrated into SOCOMEC supply

Environnemental conditionsStorage temperature - 40 ... + 70 °COperating temperature - 10 ... + 55 °CHumidity 90%HR at +55 °C / 97% at +55 °C (D-75t)Installation category Powered by SELV (safety extra low voltage) Pollution degree 2IP protection IP54 (front face) IP65 (front face)

PC

ISOM Digiware D-55 / D-75 / D-75t

Alimentation 24 VDC

Alimentation 24 VDC

ISOM Digiware D-55h

ISOM Digiware D-15h

ISOM Digiware D-15h

RS485

ISOM Digiware L-60

ISOM Digiware D-55h

ISOM Digiware D-55h

ISOM Digiware K-40h

ISOM Digiware L-60h ISOM Digiware D-55hISOM Digiware F-60

ISOM Digiware L-60h

ISOM Digiware L-60h

ISOM Digiware F-60

ISOM Digiware F-60

ISOM Digiware F-60

Ethernet

Digiware Bus

Digiware Bus

Digiware Bus

Digiware Bus

Digiware Bus

Digiware Bus Termination

Digiware Bus Termination

Digiware Bus Termination

Digiware Bus Termination

Digiware Bus Termination

Ethernet

PC

D-15h

1 ON (green) Lights if device powered

2 TEST Test of all ISOM devices blinks during test

3 INSULATION FAULT Lights if alarm on IMD

4 OVERLOAD Lights if transformer overloaded

5 OVERTEMPERATURE Lights if transformer overtemperature

1

5

4

3

2

D-55 / D-55h / D-75 / D-75t

1 ALARM (amber) Lights if alarm on IMD/IFL

2 FAULT (red) Lights if system error

3 COM (amber) Blinks if communication activity

4 ON (green) Lights if device powered

5 QUICK ACCESS Insulation -> Trends -> Location -> PMD (if available)

6 Home (long press) Previous menu (short press)

7 Load selection (long press) Scroll feeders (short press)

8 CHOICE VALIDATION

9 NAVIGATION

10 TEST Start of test sequence on L-60 & F-60

11 RESET (D-x5) or STOP BUZZER (D-55h)

5

9

61 2 3 4

7

810

11