561-MB256 plusbells-security.com/new/pdf/mb256_plus_e.pdf · 057640 Motherboard DS 7500...
Transcript of 561-MB256 plusbells-security.com/new/pdf/mb256_plus_e.pdf · 057640 Motherboard DS 7500...
561-MB256 plusIntrusion detection central control unit
Performance features
The intrusion detection control unit 561-MB256 isdesigned for use in private and commercial zones and ishighly suitable for setting up medium to large-sizedhazard detection systems.
It complies with the latest guidelines of the VdS SecurityClass C as well as the German Electrical Standards0833, Part 1 and Part 3 of Class 1, Version B.
The standard version of the 561-MB256 has thefollowing performance features:
• 4 conventional detector group inputs
• 63 BUS-1 users - connectable
• 64 BUS-2 users - connectable
• 8 freely programmable semi-conductor outputs
as well as 4 freely programmable relays
• Integrated, monitored alarm signalling device
connections
• Serial and parallel printer interface
With the corresponding extension modules as well asBUS-1 and BUS-2 users, a total of 2048 detector groupscan be realized. When fully equipped with 32 I/Omodules, 1028 conventional inputs (terminating value12.1 kOhm) are available that can be used as inputs fordetectors and switching devices.
plus
plus
• Up to 2048 detector groups can be defined, ofwhich 1028 are conventional detector groups
• Up to 250 main zones can be defined• Up to 2583 BUS-1 users can be connected• Up to 704 BUS-2 users can be connected, of
which max. 50 are operating units• Suitable for police emergency call• 19" version and add-on operating unit• Available with LCD operating unit and printer
depending on version• Programming via USB in conjunction with
PCB/laptop and software package WINFEMAdvanced
• Simple firmware update with Flash-EPROM
• Operator guidance with plain text display• Modular extensible up to max. 32 modules• Automatic maintenance interval indication• IGIS-LOOP and transmission devices can be
integrated (also multiple)• Event memory for 4000 events• Alarm memory - 20 events per main zone
• 1000 IDENT-KEY data carrier codes can bemanaged; up to 250 macros can be defined
• Access with or without code; up to 750 operatingcodes; every operating function can beenabled/disabled individually.
• Technical and fire alarm memory
With maximum upgrading with BUS-1 and BUS-2modules, up to 2583 BUS-1 users and 704 BUS-2 userscan be connected. Several detector group inputs and/orBUS users can be allocated to one detector group.Logical relationships of the individual detector groups tothe object-specific conditions are thus possible.
The central control units are mounted in the standardhousing type ZG 4. The extension modules are mountedon the back of the housing and interconnected via a flatband cable. In addition to the central control units in thehousing type ZG 4, 19” versions are also available. Thecentral control unit in the housing type ZG 4 as well asthe 19" versions, are each available with or without anintegrated printer.
The power supply (option) can be made via one orseveral power supplies/charger units of 17 Ah to 130 Ahdepending on the size of the system.
The central control units are easy to program with aPC/laptop via the parameterization software WINFEMAdvanced. Remote programming or remote control isalso possible in conjunction with a transmission deviceand WINFEM Advanced,
Options/accessories
Technical data
Rated connection voltageRated operating voltage U_bCurrent consumption at U_b, disarmed, w/o extensionEnvironmental class as per VdSProtection class as per DIN 40 050Operating temperature rangeDimensions W x H x D: Housing type ZG 4
19" versionColour: Housing
230 V AC / 50 Hz12 V DCmax. 140 mAIIIP 30-10 °C to +50 °C580 x 640 x 300 mm488 x 272 x 110 mm (incl. printer)grey white (similar to RAL 9002)signal grey (similar to RAL 7004)Front
Honeywell Security DeutschlandNovar GmbHJohannes-Mauthe-Str. 14D-72458 AlbstadtTelefon: +49 (0) 74 31 / 801-0Telefax: +49 (0) 74 31 / 801-12 20www.honeywell.com/security/[email protected]
P00169-22-0G0-0103.2006 · Subject to alteration© 2006 Novar GmbH
Optional extension modules
013220.04Connection moduleModule with slot for acoustic plug-in card and radio card.Equipped with 4 x 250 V AC / 5 A and 4 x 24 V DC / 1 A relays. 10 programmable12 V / 50 mA semi-conductor outputs as well as a main and permanent alarm outputcan be used to actuate the relays or as a semi-conductor output.
013220.05I/O basic moduleModule with 32 inputs for connecting one or several conventional detectors orswitching elements, e.g. block locks or operating units. Also available are 48 program-mable semi-conductor outputs, 32 of which can be used via programming connectorsfor clearing detector groups.
013220.11BUS-1 moduleExtension module for connecting up to 252 users. 4 independent connectionsindividually protected by fuse are available for BUS-1 users. Up to 63 BUS-1 users arepossible per connection.
013220.07BUS-2 moduleExtension module for connection BUS-2 users. 4 connections,
individually protected by fuse, are available for a total of 64 BUS-2 users.isolated against each
other and
013230Retrofit kit IDC 561-MB256 to IDCU 561-MB256 plus
This retrofit kit enables a central control unit 561-MB256 to be retrofitted to a centralcontrol unit 561-MB256 . The retrofit kit comprises the computer/connection PCB,adapter PCB for the serial printer, the assembly adapter plate, all necessary mountingand installation material as well as WINFEM Advanced.
plus
013330.10IGIS-LOOP controllerExtension module for integrating intrusion detection central control units in the IGIS-LOOP network. The IGIS-LOOP controller is the central module of the IGIS-LOOPsecurity network. If the controllers are connected in a ring, they form the core of theIGIS-LOOP.
013220.06Keypad moduleThe module enables the connection up to 4 keypad units with a matrix connection(3/4).Note: Max. 25 keypad modules can be used.
013100.08Relay extension moduleThe relay extension module is equipped with 4 x 250 V AC / 5 A relays as well as 2slots for group relay cards 070478. The module is not designed for connecting to theI-BUS. The relays are actuated via conventional connections (e.g. programmablesemi-conductor outputs).
013220.14Connection PCB for table-top printerExternal table-top printers with a parallel interface can be controlled with this PCB.With the PCB, a galvanic separation is possible between the intrusion detectioncentral control unit and the printer although the non-reactive operation of an externalprinter is guaranteed.
Housings
Relay extension
Printer/printer accessories
Power supply/charger units
RDT/transmission devices
050055 19" housing type ZG 4050056 19" housing type ZG 5050057 19" housing type ZG 6013118 19" dummy plate 6 HU, signal grey013119 19" dummy plate 3 HU, signal grey
070478 Group relay card
013900 Alphanumerical thermoprinter40-digit, with motor-driven spooling
010686.01 Power supply/charger unit 12 V DC / 17 Ah010690.01 Power supply/charger unit 12 V DC / 32 Ah010690.02 Power supply/charger unit 12 V DC / 40 Ah012168 Power supply/charger unit 12 V DC / 80 Ah012170 Power supply/charger unit 12 V DC /130 Ah050019 Distributor block
057870 Motherboard DS 6500057630 Motherboard DS 7500 ISDN057640 Motherboard DS 7500 ISDN/analogous057875 Motherboard DS 8500 ISDN057876 Motherboard DS 8500 ISDN/analogous057650 Motherboard DS 7600 ISDN057651 Motherboard DS 7700 ISDN/IP057920 Motherboard DGA 2400
WINFEM central control unit programming
013901 Paper roll (PU 5 pieces)
013498 Parameterization softwareWINFEM Advanced
026809 Zero modem cable013466 Adapter cable with 3-pole plug connector013467 USB adapter box (USB 1.1-compatible)013595 WINFEM user; Windows software for
programming on user level
013100.10 Connection cable 40 mm / 250 mm013100.11 Connection cable 400 mm013100.12 Connection cable 250 mm013100.13 Connection cable 1000 mm013100.14 Connection cable 650 mm
Connection cables
BUS-1 user
BUS-2 user
BUS-2 operating units
010109.10 1-detector group module010110.10 2-detector group module010118 2-detector group module; f.m. version010111 Universal connection module; s.m. version010112 Universal connection module; f.m. version010116 Active distributor module010125 Key switch - operating unit BUS-1015128 Radio receiver module022310.10 Door module 1022320.10 Door module 2031540 Hold-up pushbutton module032211 IDENTLOC evaluation unit032420 DETEKT 1000033370/033371/033372 PIR detector SCM 2000033401/033404/033407 PIR detector SCM 3000041150.10 Switching module 24 V DC / 1 A041151.10 Switching module 250 V AC / 5 A042235 Indoor blinking light043050 Indoor siren module043060 Piezo indoor siren062085 Smoke detector base module
013130.10 5 Input module013131.10 5 Output module022160.20 IDENT-KEY IK2 evaluation unit023312.10 IDENT-KEY IK3 evaluation unit033402/033405/033408 PIR motion detector SCM 3000 / AÜ
012540 2 x 40-digit LCD operating unit; with flap012541 2 x 40-digit LCD operating unit; w/o flap012544 10-DG oper. unit with disabling function012532 8-DG oper. unit with disabling function012542 16-DG disabling and display module012548 16-DG display module012546 flush mounting kit for 012532, 012541,012542,
012544, 012548013140 64 DG display terminal
033442 Viewguard DUAL AM BUS-2033443 Viewguard DUAL BUS-2
Retrofit - central control units
-approval pending
013222.10Intrusion detection central control unit 561-MB256 in housing Type ZG 4plus
013223.10Intrusion detection central control unit 561-MB256 in housing type ZG 4,incl. printer
plus
013224.10Intrusion detection central control unit 561-MB256 19" versionplus
013225.10Intrusion detection central control unit 561-MB256 19" version,incl. printer
plus
013228.10Intrusion detection central control unit 561-MB256 19" version,with operating unit
plus
013229.10Intrusion detection central control unit 561-MB256 19" version,with operating unit including printer
plus
Space for 8 options; space for power supply/charger unit; max. space foraccumulator 2 x 65 Ah
Slot for 8 options; space for power supply/charger unit; max. space foraccumulator 2 x 65 Ah
Computer/connection PCB;Housing type ZG 4; front plate 6 HU; dummy plate 6 HU
Computer/connection PCB; thermoprinter 103900; housing Type ZG 4;front plate 6 HU; dummy plate 6 HU
Computer/connection PCB; front plate 6 HU
Computer/connection PCB; thermoprinter 013900; front plate 6 HU
Computer/connection PCB; operating unit 012541; front plate 6 HU
Computer/connection PCB; operating unit 012541; thermoprinter 013900;front plate 6 HU
-approval pending
-approval pending