561 MANUAL DE CONTROL DE LA CONTAMINACIÓN

33
FPO V I C K E R S F L U I D P O W E R S Y S T E M S A Complete Guide for Maximum System Performance THE SYSTEMIC APPROACH TO CONTAMINATION CONTROL

Transcript of 561 MANUAL DE CONTROL DE LA CONTAMINACIÓN

Page 1: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

FPO

V I C K E R S F L U I D P O W E R S Y S T E M S

A Complete Guide for Maximum System Performance

THE SYSTEMIC APPROACH TO CONTAMINATION CONTROL

Page 2: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

Vickers Guide toSystemic Contamination Control

Contents

2 Vickers Systemic Contamination Control

3 The Systemic Approach to Contamination Control

3 Quantifying Fluid Cleanliness

5 Sources of Contamination

8 Damage Caused by Contamination

16 Setting a Target Cleanliness Level

18 Achieving Target Cleanliness

22 Locating Contamination Control Devices

27 Flushing New or Rebuilt Systems

29 Confirming and Monitoring Achievement of Target Cleanliness

31 ProActive Maintenance

Page 3: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

2

Fluid Power is one of the most reliableand repeatable forms of power andmotion control. All that is required iscomprehensive state-of-the-art systemdesign and modern systemic contami-nation control. When problems areencountered, 80% of the time they arerelated to inadequate contaminationcontrol practices. Understanding thishandbook will greatly assist the designor maintenance engineer in achievingthe balanced system cleanliness that isthe cornerstone of fluid power reliability.

Vickers has a more than 75-year history of dedication to helping engineersdevelop, operate and maintain reliable,high quality power and motion controlsystems. This guide is only part of thepackage Vickers offers to enable thedesigner and user to achieve the most effective hydraulic power andmotion control.

Introduction

For a hydraulic or oil lubricated machine, the development of a targetcleanliness level and the plan to achieveit is as much a part of system design as the selection of the pump, valves,actuators or bearings. Unfortunately,when some system designers select afilter, they look no further than a filtermanufacturer’s catalog, with little regardfor the particular system’s total require-ments. Proper selection and placementof contamination control devices in asystem to attain the targeted cleanlinesseliminates (the root cause of) up to 80%of hydraulic system failures. Additionally,the system cleanliness approach assuresthe user of the hydraulic system a cost-effective approach to contaminationcontrol that allows the price of the filtersand elements to be quickly recovered bythe savings of improved performance,increased component life, increased oillife, increased uptime and fewer repairs.

To stress the interacting relationshipbetween component design, systemdesign, filter performance and filterplacement, Vickers has named ourapproach to filters and filtration VickersSystemic* Contamination Control. Thisbook is dedicated to defining the theoryand practice of quality, cost-effectivesystemic contamination control.

Vickers Systemic Contamination Control

*systemic (si-stem' ik) adj.

1. Of or pertaining to a system orsystems.

(American Heritage Dictionary, HoughtonMifflin Company.)

˘ ˘ ˘

Page 4: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

Working toward the most effective protection consistent with economy, wemust first define our goal. In systemiccontamination control the goal is alwaysthe same: to clean the fluid to the pointthat contamination is not a factor in thefailure (catastrophic, intermittent, ordegradation) of any component in thesystem during the desired useful life ofthat system. The first step towards thisgoal is the setting of a target cleanlinesslevel that takes into account the specificneeds of the system.

Once the target has been set, the nextstep is to select and position filters inthe system so that the target can beachieved in a cost effective manner.This requires an understanding of filterperformance, circuit dynamics and filter placement. While all three factorsare important, the last two issues — circuit dynamics and filter placement —often receive much less attention thanthey require.

Today there are several sources for highefficiency filters that can initially keepthe hydraulic or lubrication fluids clean.In most systems that have contamina-tion problems, the cause is either poorlyconceived filter placement, because of a lack of understanding of the dynamicsof fluid flow, or the inability of the filterelements to maintain their performancelevels throughout their service life in the system. The engineering guidelinesneeded to deal with both filter placementand system dynamics are presented inthis document.

After the machine is in operation, the last and ongoing step is to confirm thatthe target cleanliness level is beingmaintained. This is most often accom-

plished by sending a fluid sample to aparticle counting laboratory that givescleanliness code data to establishedstandards. If the target is being met, the system only needs to have filtersmaintained and the fluid retested periodically. If the cleanliness target is not being achieved, corrective actionsneed to be taken. Sometimes a changein maintenance practices is needed, but at other times a shift to a finer grade of filter elements or additional filter housingsmay be needed. Intelligent considerationof contamination control during thedesign phase is the best way to avoidboth short- and long-term problems andgain the assurance that each hydraulicallypowered or oil lubricated machine willgive long, reliable service.

Quantifying FluidCleanlinessThe first step in setting a target cleanliness level is to understand that“cleanliness” is not a general term butrather a specific quantitative value. The current international standard forcleanliness of a hydraulic or lubricatingfluid is defined by ISO 4406. Using anapproved laboratory particle countingprocedure, the number and size (inmicrometers) of solid particles in a milliliter of fluid is determined.

Typical data from a hydraulic fluid sample counted by an automatic particlecounter is:

Vickers Systemic Approach toContamination Control

• Set a target Cleanliness Level• Select filters and filter placements

to achieve target• Sample fluid and confirm

achievement

The Systemic Approach To Contamination Control

3

Computer "reads" and classifies the particles by the changes in light received by the photo-detector

Waste fluid

Printer

2 xxx 5 xxx10 xxx15 xxx25 xxx50 xxx

Lightsource

Photo-detectorscreen

Automatic Particle Counting

Particles Size ‘X’ Number of particles in Micrometers greater than ‘X’ size

in one ml of test fluid

2µm 5120

5µm 89

10µm 43

15µm 22

25µm 3

50µm .4

(Note: Particle counts are normally run on 10 to 100 milliliters offluid and then factored to report results for 1 milliliter. This is thereason results of fractional particles can be reported.)

Page 5: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

4

Once the results are obtained, thepoints are plotted on a CleanlinessChart. This chart has range codes (farleft edge) that give a number, 0 through25, that corresponds to a specific num-ber of particles. Taking the range codefor the number of 5µm and larger parti-cles and the range code for the numberof 15µm and larger particles and com-bining them together with a slash (/)gives us the ISO Cleanliness Code forthat fluid. For the particle count in theexample, the 89 particles of 5µm andlarger size are in the 14 range and the22 particles of 15µm and larger is in the12 range. This means the example fluidis described as a ISO 14/12 cleanlinessfluid.

Unfortunately, the current ISO standarddoes have a weakness in that it canmask a significant build-up of very finesilt sized particles by the non-reportingof the counts smaller than 5µm. To remedy this, Vickers has adopted, andISO is considering, expanding the codeto three ranges correlating to 2µm, 5µmand 15µm. For the example presented,the Cleanliness Code becomes 20/14/12.Throughout this Vickers document wewill show cleanliness codes with 3ranges, the last two being bold type tosignify that they are the current ISOstandard.

20

14

X

12

X

X

Particlesize "X" in micrometer

Number of particles

greater than "X" size in oneml of test fluid

Range code

Example

Num

ber of particles greater than size per milliliter

20/14/12Cleanliness Code

Particle size in micrometers

100,000

1 2 5 10 15 20 25 30 35 40 45 50

Range Code

10,000

1,000

100

10

1.0

.1

.01

5,0004,0003,0002,000

500400300200

50403020

543

1.5

25160,000

2480,000

2340,000

2229,000

2110,000

205,000

192,500

181,300

17640

16320

15160

1480

1340

1220

1110

105

92.5

81.3

7.6

6.3

5.15

4.08

3.04

2.02

1

.2

.3

.4

.5

20,00030,00040,00050,000

150,000200,000300,000

2

5

10

15

25

50

.05

2

15

150

1,500

15,000

5120

89

43

22

3

.4

Cleanliness Code Chart

Page 6: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

5

There are four primary sources for solidcontamination to enter a hydraulic fluid.They are: contaminated new oil, built-incontamination, ingressed contaminationand internally-generated contamination.Each of these sources needs to beunderstood as each is a major consider-ation in filter placement.

Contaminated New Oil

Although hydraulic and lubrication fluidsare refined and blended under relativelyclean conditions, the fluid travels throughmany hoses and pipes before it is storedin drums or in a bulk tank at the user’sfacility. At this point, the fluid is no longerclean as the fluid lines it has traveledthrough have contributed metal and rubber particles, and the drums haveadded flakes of metal or scale. Storagetanks are a real problem because watercondenses in them causing rust particles.Contamination from the atmosphere can also find its way into the tank unlesssatisfactory air breathers are fitted.

If the fluid is stored under reasonableconditions, the principal contaminants on delivery to the machine will be metal,silica and fibers. With fluids from reputablesuppliers, sampling has shown typicalCleanliness Levels of 17/16/14 or dirtier.Using a portable transfer cart fitted with a high efficiency filter, contaminationshould be removed from new fluidsbefore the contamination enters anddamages the components in the system.

Sources of Contamination

Contamination particles found in new fluid include rust, scale, fibers and sand(photomicrograph at 100x).

Dirty New Oil

Sources of Contamination• Contaminated New Oil• Built-in Contamination• Ingressed Contamination• Internally Generated

Contamination

Page 7: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

6

Built-in Contamination

New machinery always contains a certain amount of built-in contamination.Care in system assembly and in newcomponent flushing reduces this butnever eliminates it. Typical built-in contaminants are burrs, chips, flash,dirt, dust, fiber, sand, moisture, pipesealant, weld splatter, paint and flushing solution.

The amount of contamination removedduring the system flush depends notonly on the effectiveness of the filtersused, but also the temperature, viscosity,velocity and “turbulence” of the flushingfluid. Unless high velocities and turbulence are attained, much of thecontamination will not be dislodged until the system is in operation, with catastrophic component failure a possibleresult. Irrespective of the standard offlushing executed by the machine builder,an off-load period of “running-in” shouldbe regarded as essential for any new orrebuilt hydraulic or lubrication system.

Ingressed Contamination

Contamination from the immediate surroundings can be ingressed into thefluid power or lubrication system. Onlarge installations, such as those withinsteelworks or automotive plants, it is relatively easy to know the environmentalconditions, though they vary considerably.For example, a coke oven system operates in conditions very differentfrom a similar system in a cold mill. Formobile equipment, there is a very widevariation in environmental conditions byapplication, location and even by weatherconditions (i.e. high winds).

The key is to severely limit the accessenvironmental contamination has toenter the hydraulic or lubrication system.There are four major ways dirt can enter a system: reservoir vent ports

(breathers), power unit or systemaccess plates, components left openduring maintenance and cylinder seals.

Sources of Ingressed Contamination

RESERVOIR VENT PORTS allow airexchange into and out of the reservoir to compensate for changes in fluid levelcaused primarily by cycling cylindersand thermal expansion and contractionof the fluid. All vents that exchange airneed to be fitted with barrier-type airbreather filters. Other acceptable optionsare to use bladders or flexible rubberbarriers to prevent the exchanged airfrom coming in contact with the surfaceof the system fluid or valving which prevents air changes while allowing reliefprotection against over-pressurizing the reservoir.

POWER UNIT ACCESS PLATES — In some plants it cannot be assumedthat access plates will always bereplaced, though this problem is not ascommon as it once was. Good systemiccontamination control requires thatreservoirs are designed to remainsealed during operation and any accessplates that need to be removed duringmaintenance be easy to reinstall. Themost important factor in this aspect of contamination control is the proper education of all maintenance and service personnel.

INGRESSION DURING MAINTENANCEWhenever a system is opened for maintenance, there is an opportunity forenvironmental contamination to enterthe system. All possible care should betaken to ensure that open ports are keptcovered or plugged, and component disassembly and rework is done in anarea that is protected from excessiveairborne dirt and contamination.

Sources of IngressedContamination• Reservoir Vent Ports• Power Unit Access Plates• Maintenance Events• Cylinder Rod Seals

Page 8: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

7

Lint free rags and oil absorbent materialsin “socks” (rather than loose glandularform) should be used for componentwipedown and area clean up.

CYLINDER SEAL INGRESSION — Rodwiper seals rarely are designed to be100% effective in removing the thin oilfilm and the fine contamination from thecylinder rod. Environmental dirt thatsticks to an extended rod is drawn backinto the cylinder and washed off into thesystem fluid. Every effort should bemade during machine design to avoiddirt or other contaminants from landingdirectly on extended cylinder rods.When this is unavoidable, the filtersshould be positioned and sized to capture this abundance of dirt.

Generated Contamination

The most dangerous contamination to asystem is the contamination generatedby the system itself. These particles are“work hardened” to a greater hardnessthan the surface from which they came,and are very aggressive in causing further wear in the system. In a systemrunning on properly cleaned fluid veryfew particles are generated, although allcomponents (especially pumps) create asmall amount of particles during routineoperation. In a system where these particles are not quickly captured the elevated contamination levels will causethe number of additional generated particles to increase at a highly accel-erated rate! The best way to prevent contamination generation within a systemis to start with a clean (fully flushed)system and keep the system fluid clean.

Abrasive Wear — Hard particlesbridging two moving surfaces, scraping one or both.

Adhesive Wear — Loss of oil filmallows metal to metal contactbetween moving surfaces.

Fatigue Wear — Particles bridging a clearance cause a surfacestress riser or microcrack that expands into a spall due to repeated stressing of the damaged area.

Erosive Wear — Fine particles in a high speed stream of fluid eat away a metering edge or critical surface.

Cavitation Wear — Restricted inlet flow to pump causes fluidvoids that implode causingshocks that break away criticalsurface material.

Aeration Wear — Air bubbles in the fluid implode breaking away surface material.

Corrosive Wear — Water or chemical contamination in thefluid causes rust or a chemicalreaction that degrades a surface.

Generated Contamination

Note: Suction strainers with bypass are shown as an option in many examples in this book. See page 24 for a discussion on their application.

Built-in debris

Return line filter

Generated by pump

Pressure line filter

Ingressed from air breather

Ingressedthroughreservoiropenings

Transfer cart filter

Ingressed from new oil

Generated by cylinder

Ingressed from cylinder rod

BA

P TGenerated by valve

MM M

Sources of Contamination

Page 9: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

Contaminant particles come in allshapes and sizes and are made up of awide variety of materials. The majorityare abrasive, so when they interact withsurfaces they plough and cut fragmentsfrom critical surfaces in the components.This abrasive wear and surface fatigueaccounts for almost 90% of degradationfailures.

Types of Failures

Failures arising from contamination fallinto three categories:

1. CATASTROPHIC FAILURE occurswhen a large particle enters a pump orvalve. For instance, if a particle causesa vane to jam in a rotor slot, the resultmay well be complete seizure of thepump or motor. In a spool type valve, alarge particle trapped at the wrong placecan stop a spool from closing completely.Another example of catastrophic failureoccurs when the pilot orifice of a valve is blocked by a large particle. Fine particles can also cause catastrophicfailure; a valve, for example, can fail tooperate due to silting.

2. INTERMITTENT FAILURE can becaused by contamination on the seat ofa poppet valve which prevents it fromreseating properly. If the seat is too hardto allow the particle to be embeddedinto it, the particle may be washed awaywhen the valve is opened again. Later,another particle may again prevent complete reclosure and be washedaway. Thus, a very annoying type ofintermittent failure occurs.

3. DEGRADATION FAILURE can be the result of abrasive wear, corrosion,cavitation, aeration, erosion or surfacefatigue. Each one causes increasedinternal leakage in the system compo-nents which reduces its efficiency oraccuracy, but these changes are initiallydifficult to detect. The eventual result,particularly with pumps, is likely to becatastrophic failure. The particles mostlikely to cause wear are clearance-sizeparticles which just bridge the criticalclearances between moving surfaces in the component. Oil also suffersdegradation due to the presence ofexcessive contamination.

Sizes of Critical Clearances

Manufacturing clearances withinhydraulic components can be dividedinto two principal zones, i.e. up to 5 micrometers for high pressure components and up to 20 micrometersfor lower pressure components. Theactual operating clearances for a component are set by the type of component and operating conditions itsees. These clearances help to definethe cleanliness of the fluid required by that component.

8

Damage Caused by Contamination

Particles of similar size to the clearance betweenmoving parts cause the most abrasive wear.Larger particles cannot enter clearance, smallerparticles pass through without contact.

Clearance-size particles interact with both facessimultaneously. Extra contamination is generated by the disintegration of the moving surface. Largerparticles are “ground up” by the interaction in the clearances.

Motion

Interaction of Moving Parts

Types of Failures• Catastrophic Failure• Intermittent Failure• Degradation Failure

Page 10: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

9

Pumps

All hydraulic pumps have componentparts which move relative to one another,separated by a small oil filled clearance.Generally these components are loadedtoward each other by forces related toarea and system pressure.

Since the life of most pumps is determined by a very small quantity of material being removed from a few surfaces, it follows that rapid degradationand eventual seizure will occur if the fluidwithin the clearance is heavily contami-nated. The design of low pressure unitspermits relatively large clearances andtypically only larger (10µm and larger)contamination has a significant damagingeffect. Also at the lower pressure, thereis less force available to drive particlesinto critical clearances. Increasing orpulsating the pump pressure is of majorsignificance in determining the effect ofcontamination on a pump.

1. First, stresses at componentsurface develop and lead to elasticdeformation and plastic flow of material.

2. Then, small surface micro cracks develop at or just beneath the solid surface during component use.

3. The faults then join to form largervoids undermining component surface.

4. Surface material then breaks away.

Stress risers Crack forms

Cracks and faults coalesce Particles released

Force

Repeated stress

Particle

Mechanism of Fatigue

Fluid flow

Pressure port

Spool

Metering edge

Metering edge

Erosive Wear

The metering edge of the spool and valve land has been eroded away by theparticles in the high velocity fluid flowingthrough the valve.

Page 11: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

10

Another factor affecting clearances is the oil film thickness, which is also related to fluid viscosity (film strength).An optimum viscosity value is used during design. The oil should providegood film thickness to support loadshydrodynamically, and also be thinenough to allow adequate filling of thepump without cavitation. It is generallyfound in practice that critical clearancesare larger where higher viscosities areused, and for this reason the maximumviscosity which is compatible with theinlet conditions should be chosen.Similarly, good fluid temperature controlis beneficial in this respect.

The areas in pumps particularly subjectto critical clearance wear problems are:

Vane pump – Vane tip to cam ring,rotor to side plate, vane to vane slot.

Gear pump – Tooth to housing, gear to side plate, tooth to tooth.

Axial piston pump – Shoe to swashplate, cylinder block to valve plate, piston to cylinder block.

In many of these cases, the clearancesare effectively self-adjusting under operating conditions, i.e. with increasingpressure clearances becoming smaller.Under adverse conditions, and particu-larly where there is shock loading, thereis an increased vulnerability to smallersized contamination particles. Evenwhere clearances are nominally fixed,components under high loads may takeup eccentric positions which again makethem vulnerable to smaller particles.

From engineering data and field experi-ence, Vickers has set recommended contamination levels which, if achieved,will result in an increased life for mostsystems and components. These arepresented in the next section, which dealswith setting target cleanliness levels.

The useful life of a pump ends when it no longer delivers the required output at a given shaft speed. All too often,degradation goes undetected until finallycatastrophic failure occurs, with vastquantities of contamination being releasedinto the system. Following such a failure,the life of the replacement pump will be greatly reduced if the system is notproperly cleaned or protected.

To the end user, total cost is the mostimportant issue; the failure of a low-costpump may well result in expensive downtime and maintenance. If, by theinclusion of the proper contaminationcontrol devices, such a failure can beavoided, the initial investment in suchdevices is fully recovered.

Inlet(low pressure)

Outlet (high pressure)

Wear area: tip of vane to ring

Outlet (high pressure)

Inlet (low pressure)

Wear area: vane to vane slot

Wear area: rotor to side plate

Critical Clearances in a Vane Pump

Inlet (low pressure)

Outlet (high pressure)

Minimum clearance Maximum clearance

Clearance between teeth and housing variable according to position in rotation allowing backflow of fluid with pressure.

Wear area: tooth to case

Wear area: tooth to tooth

Critical Clearances in a Gear Pump

Page 12: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

11

Motors

What has been written about pumpsapplies generally to motors because oftheir similar design. It must be remem-bered that a majority of the contaminantpassing through the pump will alsoreach the motor where it will cause asimilar performance degradation. If, for example, due to wear, the volumetricefficiency of the pump falls to 85% of its original value and the volumetric efficiency of the motor falls to 90% oforiginal, then the overall volumetric efficiency of the pump and motor willdrop to 0.85 x 0.9 = 76.5% of the original value.

Hydrostatic Transmission

Hydrostatic transmissions most oftenconsist of a servo controlled pump and a fixed volume motor. Wear to a critical

surface in any component will degradethe overall performance of the transmis-sion. Failure of a component can spreaddebris throughout the system causingextensive and expensive secondarydamage. High efficiency filtration is akey factor in achieving long, reliable service from a closed loop hydrostatictransmission.

Directional Valves

In most directional valves, the radialclearance specified between bore andspool is between 4 to 13 micrometers.As is well known, the production of perfectly round and straight bores isexceptionally difficult, so it is unlikelythat any spool will lie exactly central inthe clearance band. In a CETOP 3valve, a spool is likely to have less than2.5 micrometers clearance.

������

����������������������������������������

Swashplate

Wear area:shoe toswashplate

Wear area:piston to cylinder block

Cylinder block

Piston

Valve plate

Wear area:cylinder blockto valve plate

��������

Wear area:piston to shoe

CylinderBlock

Critical Clearances in an Axial Piston Pump

Page 13: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

12

In an electrically operated valve, theforces acting on the solenoid are: flowforces, spring forces, friction forces andinertia forces.

Flow, spring and inertia forces are inherent factors, but friction forces are to a great extent dependent on systemcleanliness. If the system is heavily contaminated with particles similar in sizeto the radial and diametrical clearances,higher forces will be needed to move the spool.

An even worse situation results from silting, where contaminant is forced into

the clearances under pressure, eventuallyleading to breakdown of the oil film andspool binding.

This situation occurs when valves subjected to continuous pressure areoperated infrequently. Such valvesshould preferably have local filtration of a high efficiency in the pressure line, but due account should be taken of possible pressure surges generated during component operation. The use offilters as a special protection for singleunits or groups of units can result in theneed for a large filter element of highcapacity, if the general cleanliness levelin the system is poor.

Some idea of the forces needed to breakthis spool binding, compared with theforce available from the solenoid, can begained from the example of a CETOP 3valve operating at 3000 psi (210 bar). If a valve of this type remains in thespring offset or energized position for alengthy period of time, silting takes placebetween spool and bore and can causetotal immobility. The force needed toovercome this state has been foundthrough experiments to be approximately30 pounds, but both spring and solenoidare designed to exert only 10 pounds.The effect of the excessive silting can betotal system failure.

To Actuator From Pump From Actuator To Tank

Solenoid Force

Silt collects in tight clearance leak paths causing increased resistance to shifting*

*

*

*

*�

��

��

Valve Spool Clearances (with flows and forces)

One large particle can bridge gap

Working pressure

Break in oil film due todirt concentration

Silt build-up

Valve Spool Critical Clearance

Page 14: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

13

Pressure Controls

Abrasive particles in high velocity streamsof oil erode internal surfaces. This situation is common to pressure controls,particularly relief valves which are subjected to maximum system pressuredrop. Pilot control stages generally seelow volumes at high velocities, andheavy contamination affects both theirstability and repeatability.

Flow Controls

The contamination tolerance of flow control valves will depend very much onthe orifice configuration. Two differentorifices which are of entirely differentshape can have equal areas. The groovetype will tolerate a high contaminationlevel, except when used at low setting,whereas a flat cut orifice is much moreprone to silting at all settings.

With all types of pressure compensatedflow controls, the performance of thepressure reducing element can be considerably affected by contamination,irrespective of valve setting. Damage tothe metering orifice can also occur,which will become particularly apparentat lower settings.

Generally speaking, all spool-type controlvalves are affected by contamination inthe system, especially at high pressures.The effects are likely to be magnified ifprecise axial positioning of the spool isnecessary as, for example, in pressurereducing valves where limited forces areavailable to operate the spool. On theother hand, poppet valves, though affected by large particles of contamina-tion, tend to be far more tolerant of siltdue to the self-cleaning action of theseat. However, erosion of critical seatsurfaces must be avoided.

Bearings

In both rolling and siding contact bearings, a thin oil film separates the ball from the race or the journal surfacesfrom the shaft. As long as there is nodirect contact between the moving parts,the expected fatigue life of the bearingapproaches infinity. The most commonway for direct contact to happen is tohave a particle bridge the oil film andcontact a moving and stationary surfaceat the same time. The resulting damageis often a scratch or surface crack thatinitiates the spalling process. In mostbearings, particles as small as 3µm canhave a negative impact on the life of thebearing or system.

Outer race(Stationary)

Rolling elements

Typical clearance betweenthe rolling elements of a bearingand the outer and inner race can be less than 2µm.Particles in the lubrication fluid are rolled into this critical clearance causing a surface micro crack,initiating the spalling process.

Inner race(Shaft rotation)

Bearing Wear

Note: Throttle profile gives orifice segments of equal area

(a) (b)

Flow Control Valve Throttle Sections

Page 15: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

FPO

FPO FPO

14

Piston head contamination damage — Shoes can also become loose on the piston head as aresult of severe scoring and pitting from contamination.

Telltale effects of contamination and seizing on the piston diameter can be seen in these photos. Pistons in this condition cannot be reworked.

Piston/shoe Subassembly

Ruined Pistons

Page 16: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

FPO

15

contaminants, wear will occur, therebygenerating further particles which may beground into many more smaller particles.Fine particles, individually or in smallquantities, may not cause damage. But ifpresent in slightly higher concentrations,they can lead to failure through silting.

Examples of Wear on Actual VickersComponents

Vickers guide to Pump Failure Analysiscontains many examples of failurescaused by contamination. Typical contamination damage to a piston/shoe,piston and cylinder block is shown here.

Summary

As explained above, an individual largeparticle arriving at the wrong place at the wrong time can cause catastrophicfailure. A small quantity of silt-sized particles can also cause problems byeroding a surface or by building up in acritical area.

Surfaces within components aredesigned to be separated by an oil film,the thickness of which may be continuallychanging. When this gap is bridged by

The individual cylinder bores within a cylinder block are prone to excessive wear and tear.This can be due to dry run, lack of lubricity in the fluid or contaminants. Cylinder blocks withworn or scored bores should never be reused.

The top surface of a cylinder block that contacts the valve plate can also become scored orpitted due to improper operating conditions such as aeration, cavitation, contamination andhigh system temperature.

Piston Pump Failures—Cylinder Block

Page 17: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

16

Setting a Target Cleanliness Level

As stated previously, all hydraulic andlubrication systems should have a targetcleanliness level for that specific systemclearly stated in their engineering docu-mentation. This target should be set afterconsidering the components in the sys-tem (including the fluid), the typical oper-ation and start-up temperatures, the dutycycle, the systems’ required useful lifeand safety issues. As the actual cleanli-ness level of the fluid varies by samplingpoint within the system (i.e. reservoir,pressure line, return line, etc.), the targetcleanliness level is assumed to be set forthe return line upstream of the return linefilter, unless stated otherwise.

In 1976, Vickers first issued a chart giving suggested minimum cleanlinesslevels for acceptable component life.This graph has been the basis for muchthat has been written and learned sinceits publication.

The following chart and procedure have been prepared to help design andmaintenance engineers set a targetcleanliness level. The cleanliness levelrecommendations are based on engi-neering evaluations (including materials,critical clearances and machining toler-ances) and practical field experienceswith Vickers and other brands ofhydraulic or load bearing components.

Pre

ssur

e in

PS

I (ba

r)

Contamination level

Average hydraulic components including most pumps

Very sensitive components

Very tolerant components

4500(306)

3000(204)

1500(102)

Note: This graph assumes viscosity to be within recommended range.

Note: Graph modified to show 3 code cleanliness levelscorresponding to the earlier ISO cleanliness codes.

17/15/11 18/16/12 19/17/13 20/18/14 21/19/15 22/20/16 23/21/1716/14/1015/13/9

Suggested Cleanliness Level for Good Component Life (circa 1976)

Setting a Target Cleanliness Level• Determine the cleanliness recom-

mended for the most sensitivecomponent in system

• Adjust code for fluid type• Adjust code for external factors

that increase the stress on the system components

Note: Vickers components are

designed and manufactured to high

standards that maximize their dirt

tolerance. Special materials, surface

preparations, and flow paths are

utilized to ensure reliable operation.

However, Vickers and all other brands

of components operate best on

properly cleaned fluids. Vickers has

prepared these recommendations

to help users of hydraulic and oil

lubricated machines maximize the

in-service life of their individual

components and the total system.

These recommendations are

more valuable than traditional

recommendations that focus on the

maximum allowable dirt rather than

the cleanliness needed for long,

trouble free operation.

Page 18: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

17

How to Set a Target Cleanliness Level

STEP ONE

Using Vickers Recommended Cleanliness

Code Chart, determine the cleanest fluid

(lowest code) required by any component

in the system. All components that draw

fluid from a common reservoir should be

considered to be part of the same system

even if their operations are independent or

sequential (i.e. a central power unit running

several different machines). The pressure

rating for the system is the maximum

system pressure achieved by the machine

during a complete cycle of operation.

STEP TWO

For any system where the fluid is not 100%

petroleum oil, set the target one Range

Code cleaner for each particle size.

Example: If the cleanest code required

was 17/15/13 and water glycol is the

system fluid, the target becomes 16/14/12.

STEP THREE

If any two or more of the following

conditions are experienced by the machine

or system, set the target cleanliness one

level lower for each particle size.

• Frequent cold starts at less than

–18°C (0°F)

• Intermittent operation with fluid

temperatures over 70°C (160°F)

• High vibration or high shock operation

• Critical dependence on the system as

part of a process operation

Looking at the example above, if this

system was expected to cold start and a

failure could stop all production, the target

cleanliness would become 15/13/11.

Using this three-step procedure the

system target cleanliness code for the

system is now set.

*Requires precise sampling practices to verify cleanliness levels.

PUMPS< 2000 PSI < 3000 PSI < 3000 PSI

Pressure < 140 Bar ≤ 210 Bar > 210 BarFixed Gear 20/18/15 19/17/15 18/16/13Fixed Vane 20/18/15 19/17/14 18/16/13Fixed Piston 19/17/15 18/16/14 17/15/13Variable Vane 19/17/15 18/16/14 17/15/13Variable Piston 18/16/14 17/15/13 16/14/12

VALVES≤ 3000 PSI > 3000 PSI

Pressure ≤ 210 Bar > 210 BarDirectional (solenoid) 20/18/15 19/17/14Pressure (modulating) 19/17/14 19/17/14Flow Controls (standard) 19/17/14 19/17/14Check Valves 20/18/15 20/18/15Cartridge Valves 20/18/15 19/17/14Screw-in Valves 18/16/13 17/15/12Prefill Valves 20/18/15 19/17/14Load-sensing Directional Valves 18/16/14 17/15/13Hydraulic Remote Controls 18/16/13 17/15/12Proportional Directional (throttle) Valves 18/16/13 17/15/12*Proportional Pressure Controls 18/16/13 17/15/12*Proportional Cartridge Valves 18/16/13 17/15/12*Proportional Screw-in Valves 18/16/13 17/15/12Servo Valves 16/14/11* 15/13/10*

ACTUATORS< 2000 PSI ≤ 3000 PSI > 3000 PSI

Pressure < 140 Bar ≤ 210 Bar > 210 BarCylinders 20/18/15 20/18/15 20/18/15Vane Motors 20/18/15 19/17/14 18/16/13Axial Piston Motors 19/17/14 18/16/13 17/15/12Gear Motors 21/19/17 20/18/15 19/17/14Radial Piston Motors 20/18/14 19/17/15 18/16/13Swashplate Design Motors 18/16/14 17/15/13 16/14/12

HYDROSTATIC TRANSMISSIONS< 2000 PSI ≤ 3000 PSI > 3000 PSI

Pressure < 140 Bar ≤ 210 Bar > 210 BarHydrostatic Transmissions 17/15/13 16/14/12* 16/14/11*

(in-loop fluid)

BEARINGSBall Bearing Systems 15/13/11*Roller Bearing Systems 16/14/12*Journal Bearings (high speed) 17/15/13 >400 RPMJournal Bearings (low speed) 18/16/14 <400 RPMGeneral Industrial Gearboxes 17/15/13

Vickers Recommended Cleanliness Code Chart

Page 19: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

18

There are four major factors in positioningcontamination control devices in ahydraulic or lubrication system to achievea target cleanliness level. They are:

• Initial filter element efficiency

• Filter element efficiency under system stress

• Location and sizing of contaminationcontrol devices in the system

• Filter element service life of the system

Filter Element Initial Efficiency

The international standard for rating theefficiency of a hydraulic or lubrication filter is the Multipass Filter PerformanceBeta Test (ISO 4572). The results of thistest are reported as a ratio of number of particles greater than a designatedsize upstream of the test filter comparedwith the number of same size particlesdownstream of the test filter. These resultsare then expressed as a Beta ratio.

Multipass testing has greatly aided engineers in the development of betterand more efficient filter elements, and it has helped the design engineer whoneeded to specify a filter element’s performance. But, there’s little correla-tion between multipass efficiencies and system cleanliness needs. In thefinal performance analysis, the goal isproperly cleaned fluid and not just veryhigh Beta ratios and dirt capacity. Themost important information needed by adesigner or user of a hydraulic system is

Achieving Target Cleanliness

Recirculating test stand fluidFresh contaminant

Test Filter

Upstream particle counter

Downstreamparticle counter

slurry

The Multipass Filter Performance Test

Beta Ratios Efficiency

1 0%2 50.00%5 80.00%

10 90.00%20 95.00%75 98.70%

100 99.00%200 99.50%

1000 99.90%5000 99.98%

Beta ratios and dirt capacity are only aguide to system cleanliness needs.

Beta Ratios andCorresponding Efficiencies

Nominal Filtration Rating

Absolute Filtration Rating

Filtration Ratio (Beta)

Nominal Rating—An arbitrary micrometer value indicated by the filter manufacturer. Due to lack of reproductivity, this rating is deprecated.

Absolute Rating—The diameter of the largest hard spherical particle that willpass through a filter under specified test conditions. It is an indication of thelargest opening in the filter element.

Filtration Ratio (ßn) — The ratio of the number of particles greater than a given size upstream of the test filter divided by the number of particles of thesame size downstream of the test filter.

Filter Ratings

Achieving System Cleanliness• Select a filter with Bx = > 100

performance• Select a filter with high strength

under system stress• Locate the filters so that they see

sufficient system flow to capturethe contamination

• Select a filter which will providelong in-service life

Page 20: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

19

the system cleanliness they can expectwhen that filter and media are properlyinstalled in the system.

Each grade of Vickers high efficiency filter media construction is thoroughlymultipass tested and then rated with thesystem cleanliness level expected to beachieved with the use of that product.The assumptions behind these cleanli-ness ratings are: 1) the filter sees full

system flow, 2) the filter is the primaryfilter in the system, and 3) air breathersalong with recognized maintenancepractices will limit dirt ingression fromthe atmosphere.

Coated Steel Mesh

Non woven synthetic diffuser layer

Non woven synthetic diffuser (drainage) layer

Proprietary Vickers glass micro fiber media with special resin binder

Coated Steel Mesh

Vickers Media Construction

Laboratory Procedure Real World

Pressure Rise One gradual rise Thousands of changes

Fatigue Cycles One Millions

Element Aging Minutes Months

Element Life One hour 800+ hours

Contaminant AC fine test dust Debris, water, gas

Challenge Rate Constant Always changing

Fluid Used MIL 5606 Wide variety

Temperature 100°F (38°C) -20°F to 200°F (-7° to 93°C)

Flow Steady Thousands of changes

Limits on Correlation Between “Beta” and System Cleanliness and “Dirt Capacity” and Service Life

Page 21: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

20

Filter Efficiency Under Stress

A major problem in correlating multipasstest claims to real world fluid cleanlinesslevels is that real systems operationgreatly stresses the element. In activesystems, flow rate changes (often severala minute), pressure pulses (hundreds aminute), decompression shock waves,cold starts, and other variables all workto degrade a filter’s performance. In multipass testing the element is subjectto one gradual rise in differential pressureas the element loads!

Flow fatigue test protocol (ISO 3724)leaves many important questions unan-swered. Again the element is tested in laboratory conditions that cannotduplicate the interaction of the manyforces working to stress and degradethe element. This laboratory test mayfail to answer the question of how anaged element will perform during the latter part of its service life.

The best way to deal with this issue is to look at the construction and feel theelement pleats. Are the pleats well supported? Do they flex under handpressure? Any element that fails thesesimple tests will fail to maintain efficiencyand integrity, and will not maintain thetargeted cleanliness level.

Additionally, look at the pack construc-tion. Steel wire mesh is very important in element construction. Wire keeps thepleats from flexing, and gives the filtermedium the support it needs to keep fromfailing due to fatigue. The downstreamwire mesh also serves as a last chanceprotection in case of unexpectedly severestress that causes element media rupture.

Code Number of times flow from pump passes Typical ISO 4406 cleanlinessthrough the system filters (See Note 1) level achieved (See Note 2)

03 2.0 14/12/101.5 15/13/111.0 16/14/12.5 17/15/13

05 2.0 16/14/121.5 17/15/131.0 18/16/14.5 19/17/15

10 2.0 18/16/141.5 19/17/141.0 20/18/15.5 21/19/16

For target cleanliness level selection assistance and proper filter placement guidelines, consult your local Vickers Distributor.

System Cleanliness Ratings

In poorly supported elements, changes in flow and pressure drop cause the sides of element corrugations to flex and the root to stretch, giving rise to fatigue

stresses. Dirt capacity is also lost as areas of the medium have no flow.

No flow

Deflection underhigh flow

High stress underhigh flow conditionscauses pleat to deform.

Filter medium

Flow directions

Flow fatigue failure iscommonly at root of pleat.

Changes in Flow

Systems Flow Passes thru Filters Typical Filter Placements

2.0 Full flow pressure and return

1.5 Full flow pressure or returnand recirculation loop

1.0 Full flow pressure or return line

0.5 Recirculation loop sized to 15% of system volume per minute

Note 2

Cleanliness level achieved is affected by

percentage of system flow that passed thru

the filters, filter housing integrity, element

performance and contamination ingression

and generation rates. For more detailed

assistance, please contact your local

Vickers Distributor.

Note 1

Page 22: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

03

03

03

03

03

03

03

05

05

05 or 10

05

05

10

10

05

05

05 or 10

10

05

05 or 10

10

10

03

03

05

05 or 10

03

03

05

14/12/10

15/13/11

16/14/12

17/15/13

18/16/14

19/17/15

Full flow pressure line or return line

Full flow pressure line and return line

Recommended filterplacements for highingression systemswith fixed volume

pumps

Pressure or return and recirculating loop at20% of system volume

per minute

Recommended filter placements for

systems with variablevolume pumps

Pressure line plusreturn line plus

recirculating loop

Recommended filter placements for highingression systems

with variablevolume pumps

Recirculating loopat 20% of systemvolume per minute

Recirculating loopat 10% of systemvolume per minute

21

Filter Placements

Note: All systems need a sealed reservoir with 3 micron air filtration.

Targ

et C

lean

lines

s

This chart helps the engineers select the grade of media and the filter placement(s) that will achieve the required target cleanliness. It assumes the system will experience “average” ingression and that maintenance of the system will be consistent with current technology. If in operation the system is running dirtier than expected, corrective actions should be initiated. Suggestedcorrective actions are:

1. Consider using a finer grade of media.2. Add a filter to the system.

Without proper support, the fibers forming the bonded media layer can deform, allowing contamination to pass through the filter.

Supported fiber matrix after repeated stress Inadequately supported matrix after repeated stress

Filter Matrix BreakingElements without downstream wiremesh are not recommended for use inhydraulic or lubrication systems witheven mild stress. This rule is importantas the relatively higher cost of wiremesh has lured some filter manufactur-ers to take the wire mesh out and usecheaper substitutes without dealing withthe real world issues of stress and lastchance protection.

Page 23: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

22

Locating Contamination Control Devices

Hydraulic Systems — Open Loop

Filter placements in hydraulic systemscan be categorized by the three majorfunctions they can perform. These are: ingression prevention, systemcleanliness maintenance, and compo-nent isolation.

Ingression prevention

All air entering the reservoir needs to be filtered. Removing dirt from air ismany times easier than removing it fromoil. The first step is to make sure thereservoir is sealed and to ensure thatthe exchange air enters the reservoironly across sufficiently-sized air filters

that are able to extract particles of a sizeof 3 µm or more from the air. The port(s)needs to be fitted with a Vent Filterdesigned to remove particles 3 µm andlarger from the air (grade “10”).

All fluids entering the system shouldpass through a high efficiency filter(grade “03”) before they are added to asystem. This is often accomplished byfitting a Transfer Cart with a filter directlydownstream of the pump and then usinga quick connect coupling (half mountedto the reservoir, half on the dischargehose) requiring the fluid to be pressurepumped into the reservoir. An alternateplan is to have a procedure that requiresthe fill fluid to pass through the returnline filter to enter the system. A thirdalternative is to use the recirculatingpump as a fill pump with the filter in thekidney loop to clean the new oil.

Maintaining System Cleanliness

There are three main places in a circuitwhere contamination control filtersshould be located: Pressure line(s),Return line(s), or Recirculating loop.

A pressure line filter should be fitteddirectly downstream of any fixed volumepump operating over 2250 psi (155 bar) and any variable volume pumpoperating over 1500 psi (103 bar). Therotating group of a pump has a mixtureof sliding and rolling contact surfaceswhich are stressed by high pressure orchanging pressure operation. As such,an operating pump is always producingsome wear debris. For systems withservo or proportional valves, a highpressure filter should always be usedregardless of pump type or pressure.The pressure line filter should be con-sidered the total system contaminationcontrol device only if it sees maximumpump flow during more than 60% of themachine duty cycle. If no additionalreturn filter is used, this layout allowsthe dirt returned from the system to

Filter bypass setting: ∆p = (50 psi) 3,5 bar

Filter bypass setting: ∆p = (50 psi) 3,5 bar

Duty cycle.System continuously on-load with frequent actuator operation.

Pumpoutlet:30 L/min

M

BA

P T

BA

P T

BA

P T

BA

P T

Pressure and Return Line Filtration

Pump

Pressure line filter

(to system)

Check valve

Relief valve

Tank

Pressure Line Filter

Locating Contamination ControlDevices in Open Loop ApplicationsMain System Contamination Control• Pressure Line• Return Line• Recirculating LoopComponent Isolation• Sensitive Components• Safety Issues

Pressure Line Filters• Fixed Volume over 2250 psi

(155 bar)• Variable Volumes over 1500 psi

(103 bar)• System with Servo or Proportional

valves

Page 24: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

23

pass the pump, therefore causingincreased wear in the pump before it isfiltered out.

The return line is an excellent locationfor the main system contamination con-trol filter, as long as it sees at least 20%of system volume each minute. In caseswhere return line flow is less than the20% minimum (periods of operation withthe pump in compensation), a supple-

mentary recirculating pump and filtershould be designed into the system.Often systems that need recirculating filters also need off-line cooling loops;both these needs can be met by a sin-gle pump/motor with the filter upstreamof the cooler.

Flow amplification can cause problemsfor return line filters. Cylinders with a 2:1 or greater differential area between

the piston area and rod side piston areamean that during part of the machineduty cycle flow rates can be 2 timespump flow or more. In systems with very high or severely pulsating flows,recirculating loop filters are often thebest choice.

Basic arrangement of return line filtration.

Linear actuator

Directional valve

Relief valve

Tank

Return linefilter

BA

P T

M

Return Line Filtration

M M

Filter setting: ∆p = 2,5 bar(35 psi);Bypass:∆p = 3,5 bar(50 psi);

Duty cycle. Pump on load continously meeting the flow demands with pressurecompensated control.

Off-line pump:56 L/min (15 gpm)

Reservoir capacity: 220L (60 gal.)

BA

P T

BA

P T

BA

P T

BA

P T

Off Line Filtration System

Page 25: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

24

Component Isolation

Filters to isolate components should beconsidered for systems or machines toprotect downstream components in theevent of a pump or other major compo-nent failure. Additionally, certain classesof components need dedicated protec-tion based on their design clearance orfine metering edges.

Whenever a primary failure can cause a secondary failure with unacceptableconsequences, an isolation filter orstrainer should be placed upstream ofthat component. Since pumps havefinite life and as they fail the debris travels downstream to the valves, careshould be taken to place a strainer in-lineahead of any valve that has a safetyconsideration or critical function to the system.

Servo and proportional valves have finetolerance spools that modulate in reac-tion to small changes in pilot flow or proportional solenoid forces. Even small quantities of fine silt can causedegraded operation. Individual valves orbanks of valves should be isolated witha non-bypass filter that protects thesecomponents from silt and chips thatcould enter a system during maintenanceof other components. For large servo orproportional valves with external pilotflow, a smaller, less expensive non-bypassfilter 1 can be placed in the pilot linewhile the main valve is protected by thesystem filter 2 . Filter 3 is an optionallocation. A common mistake that shouldbe avoided is selecting a component

isolation filter that is finer than the system filter. This forces the isolation filter to perform the general systemclean-up function, and results in veryshort element life.

A location not recommended for filterplacement is in the case drain flow from open or closed loop pumps. Theshaft seal on all pumps must maintain a zero leak seal under very low differen-tial pressure conditions. These sealsexperience accelerated wear wheneveradditional back pressure is added to thepump case. If a filter is being consideredin a case drain application it should bereviewed with consideration of the effect it will have to the shaft seal life.

(to system)

Relief valve

PumpTank

Tank

Pressure line filtrationwith a fixed pump anda non-bypass filter.

Pressure Line Filtration

Component IsolationProtects:• High Cost Components• Safety Functions• Against High Cost DowntimeProtects Sensitive Components:• Servo Valves (all brands)• Proportional Valves (all brands)

Page 26: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

25

Hydraulic Systems–Closed Loop

The fluid cleanliness level that is signifi-cant to a closed loop hydraulic system’slong-term dependability is the “in-loop”fluid cleanliness. Normally a high effi-ciency filter in the charge pump line willmaintain the required cleanliness. But,for hydrostatic transmissions running ator near their maximum pressure, in-loopfilters with reverse flow valving are rec-ommended. These filters will also protectthe motor in case of a pump failure.Remember to consider the percentageof time the transmission runs in eachdirection when locating the filter. For bi-directional operation with approximately50% of the duty cycle in each direction,two filter housings should be used.

M

M

Motor valve

package

1. Off line filtration as main operating filtration

2. High efficiency filter on charge flow (preferred location)

2

1

Closed Loop Hydrostatic Transmission

BA

P T

M

From otherfunctions

To otherfunctionsRelief

valve

Pump

Non-bypass filterin the pressure lineof a servo valve

Non-bypass filter in the pillot line of a servo valve

Return line filter forsystem containment control

Note: Return line filter gradeshould be as fine or finer thanthe non-bypass filters

3

2

1

BA

P TX Y X Y

T

P

Non Bypass Filter Ahead of a Servo Valve

Page 27: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

26

Lubrication Systems

There are two locations for filters in alubrication system: pressure line andrecirculating loop. For pressure line operation, the filter should be “duplexed”allowing for on line element change whilethe system is in operation. Recirculatingloop filters are excellent (applicationlocation) as long as the loop flow is atleast 50% of the main pump flow.

Filter Condition Indicators

After the filters are placed within the system, the next consideration is how theuser is going to know when to changethe element. The answer recommendedin DIN 24550 standard is to have all filters fitted with a differential pressureindicator that gives an easy-to-read indication that the element needs to bechanged. Vickers indicators are designedto indicate at a pressure drop 20%below the bypass setting which equatesto 95% of the element’s service life. Thisindication before bypass feature wasincorporated to allow safe operation ofthe machine until the next shift change orconvenient maintenance opportunity.

MCooler

Central lubrication system with Duplex filtersand a recirculation cooling and filtration loop.

Pump

Filter

Relief valve

to bearings

M

Central Lubrication System

Diff

eren

tial p

ress

ure

acro

ss e

lem

ent

Time in service (increasing dirt loading) 5% of element service life

Bypass valve cracking pressure

Setting

Pressure drop

{

Initial element

Indicator

Element Differential Pressure Build-up with Dirt LoadingFilter Condition Indicator• All filters should be fitted with a

condition indicator

Page 28: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

27

Flushing New or Rebuilt Systems

The most critical time in the life of ahydraulic or lubrication system is the initial run-in period. During this timemuch of the manufacturing debris inthe components and any debris addedduring the assembly process are washedthrough the system. It is critical that thiscontamination be captured quickly andremoved from the system while it is inoff-load operation.

New System Flushing

There are three steps to a flushingprocess. First, the machine must feedsystem fluid through all lines and com-ponents. Second, this process must dislodge the dirt from all componentsand lines, and third, the contaminationsmust be captured with a high-efficiencyfilter. Dislodging and transporting dirt is best accomplished by using a low vis-cosity fluid traveling at high line velocity.Special flushing fluid can be used or the actual system hydraulic fluid can beused at an elevated temperature. To get flow through all the lines, all thevalves should be operated severaltimes. In some cases, lines need to beconnected around a component to allowhigh flow fluid to travel through the line.Capture of the debris to flush to a clean-liness level of 16/14/11 reasonablyquickly is best accomplished with aVickers filter using “05” media. Thisproduct has the combination of high efficiency and high capacity needed toachieve a successful flush.

Flushing target cleanliness levels shouldbe two ISO codes below the targetcleanliness level for system operation.When the new oil is introduced into theproperly flushed system, less time andfilter element life will be consumedreaching system equilibrium.

Element Service Life

As in any aspect of machine design ormaintenance, cost of installation andoperation is a very important concern.For filters, the length of time an elementlasts in service, and the initial cost of that element, combine to determine the economics of using that product.

The most important aspect of gaininglong element service life is to minimizethe ingression! Reservoirs need to be fitted with vent filters (=< 3µm) that removethe dirt before it enters the system.Access port and doors need to be keptsealed so that dirt cannot be drawn intothe system. Cylinder rods that extendinto contamination laden environmentsshould be shielded to minimize the dirtbeing drawn into the system.

The second important aspect to longelement service life is to keep the clean-liness level of the fluid at or below target.Periods of machine operation with dirtyfluid cause accelerated internal wear thatloads a filter element. (It’s important thedebris is caught as it saves the system,but it does cost the element part of itsservice life.) Always change an elementon indication and always use genuineVickers elements because of their consistent performance and superiorstrength under stress.

New System Flushing• Dislodge the dirt and transport

it to the filter• Flow fluid through all lines and

components• Capture the dirt with a high

efficiency filter

Element Service Life• Minimize ingression• Maintain a constant cleanliness• Use an element with high dirt

capacity• Use elements with greater

media area

Page 29: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

28

The third issue in long element servicelife is the “dirt capacity” of the element.This value is calculated as part of themultipass efficiency test. Because of themany differences between the test con-ditions (Fine Test Dust [ACFTD] contam-ination, single pressure rise, etc.) andreal system operation, different dirtcapacity values do not correlate well tochanges in element service life. Dirtcapacity can only be used to compareelements under very specific laboratorysituations, and as a result published dirtcapacity values should be used as gen-eral information rather than specificcomparable data.

Vickers elements are designed to givelong life and reliable service in hydraulicor lubrication applications. This isachieved with our multi-layer construc-tion. Each layer provides additionalstrength or capacity leading to overallsuperior performance. Some elementsfocus heavily on media structure only,which can give increased “dirt capacity”under laboratory conditions, but noincrease in service life is experienced in real systems.

An often overlooked aspect of dirtcapacity and service life is the effect of element area. When comparing anelement of “x” area with an element of“2x” area, one would expect twice thelife for the larger element. But, in realsystems, the life extension is most oftenbetween 2.5 and 3.5 times as long. Thisis because the reduced flow densitythrough a unit area of media allows formore effective contaminant capture.Larger elements are the most cost effec-tive approach to contamination controlfrom the perspective of operating costs.

Rat

io o

f ser

vice

life

incr

ease

Ratio of filter area increase

11

10

9

8

7

6

5

4

3

2

11 2 3 4 5 6 7 8

Element Service Life versus Element Area

Page 30: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

FPO

29

Confirming and Monitoring Achievement of Target Cleanliness

Once the target cleanliness level hasbeen set, and the filters have beenselected and located in the system, thelast and ongoing step is to confirm andmonitor that the target cleanliness isbeing achieved. The best way to confirmthe target is being reached is to take arepresentative sample from the returnline, ahead of the filter and send it to aqualified laboratory that reports particlecounting per ISO 4406 (modified toinclude 2µm counts).

Quality laboratories, like the VickersFluid Analysis Service, report the cleanli-ness level with three ranges codes corresponding to 2µm, 5µm, 15µm. From this information, it is possible todetermine that the hydraulic or lubrica-tion system has the clean fluid it needsfor long dependable operation.

New developments in the environmentalsciences have resulted in passage oflaws concerning the disposal of usedhydraulic or lubrication fluids. Cost conscious users of petroleum productshave discovered that it is far more costeffective to extend useful oil life by asmuch as 4-6 times through better contamination control and Systemic

Contamination Control practices, therebyavoiding the high costs of frequentreplacement and disposal of aged fluids.For more detailed information on howyou can realize these savings contact aVickers distributor trained in systemiccontamination control.

Taking A Representative Sample

Taking a representative sample is a veryexact science. Generally, the right placeto sample a system is in the return linedirectly ahead of the return line filter. It is good system design to install a per-manent sampling valve in that location.Alternate locations for sampling are totake a reservoir sample using a vacuumpump and clean tubing, or sampling fromthe pressure line directly downstream ofthe pump. An important factor with reser-voir sampling is to be sure the end of thesampling tube is about half way downinto the fluid, otherwise “stratification”within the reservoir can cause the sampleto be non-representative. Reservoir sampling is the least recommendedalternative because of the potentiallyinconsistent sampling and the need toopen the system, inviting contamination,to obtain the sample.

Vickers Fluid Analysis service provides: Ultra clean sample bottle • Sampling instructions • Submittal form • Protective bag • Mailing box

Monitoring System Cleanliness• Sample from the return line ahead

of the return line filter• Sample from an active system• Obtain particle counts for 2µm,

5µm and 15µm

Fluid Sampling KitNew Oil versus Filters• The high financial and environ-

mental cost of oil disposal makesfiltering the better option

Page 31: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

In all sampling situations it is criticalthat the system be in operation or justshut down when the sample is taken.This assures that the fluid is turbulentand that the contamination in the system is circulating and available to be captured in the sample bottle.

Once the cleanliness level has beenachieved and confirmed, normal main-tenance practices dictate that a systembe resampled at regular intervals toreconfirm that the proper cleanlinesslevel is being maintained.

If the cleanliness level code value rises,meaning the system is running dirtierthan it should, the first thing to check isif new ingression is entering the system.Check to be sure that all access doorsare closed and that the vent filters arefitted and operational. Next, check to seeif the filters are on bypass; if so, replacethem with the appropriate genuineVickers filter elements. Lastly, it may benecessary to add a filter to the system.The most common solution is to add a recirculating loop, (pump, motor andfilter) to the reservoir.

After any maintenance activities whichmay introduce contamination, such ashose replacement or pump repair, anew sample should be taken to confirmthat the target cleanliness level is stillbeing maintained.

30

Systems with target cleanliness 17/15/12 or lower

System Pressure < 2000 psi 2000 - 3000 psi > 3000 psi

(140 bar) (140 - 210 bar) (210 bar)

8 hours of operationper day 4 months 3 months 3 months

Over 8 hours of operationper day 3 months 2 months 2 months

Systems with target cleanliness 18/16/13 or higher

System Pressure < 2000 psi 2000 - 3000 psi > 3000 psi

(140 bar) (140 - 210 bar) (210 bar)

8 hours of operationper day 6 months 4 months 4 months

Over 8 hours of operationper day 4 months 3 months 2 months

Note: Initial commissioning or major rebuild

Large system (2000 liters (530 USgal) or more) and systems with servo valves

• Sample fluid before start-up• Sample fluid during first day running• Sample fluid after one week• Sample after one month operation

Other systems

• Sample during first day running• Sample after one month operation

Systems in distress or immediately after a maintenance event

(i.e. increased heat, erratic operation, unusual sound, etc.)

• Immediate

Recommended System Sampling Frequency Chart

Page 32: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

31

ProActive Maintenance

Vickers is committed to the practice of systemic contamination control

and superior performance of our filter products.

Vickers will extend by one year, the standard warranty on all Vickers products used in a system

that is protected by Vickers filters (and elements) applied consistently with the principles

presented in this document.

VICKERS WARRANTY EXTENSIONAn important new technology currentlybeing developed for hydraulics and lubrication systems is ProActiveMaintenance. The concept, a significantpart of systemic contamination control, is to place sensors in the fluid flow andallow their outputs to be combined andcomputer analyzed to make diagnosticstatements about the operational health ofthe machine. This emerging technologyholds great promise for increasing thereliability of fluid power and oil lubricatedmachines. Vickers is the leader in thedevelopment of both SystemicContamination Control and ProActiveMaintenance technology.

Vickers Support

Vickers is committed to assisting users of hydraulic and lubrication systems toachieve the long reliable service lifedesigned into these systems. Our factoryand distributor personnel are well trainedin systemic contamination control andcan help both design and maintenanceengineers. If you have any questions, orneed additional assistance, please feelfree to call Vickers or our local distributor.

Page 33: 561  MANUAL DE CONTROL DE LA CONTAMINACIÓN

All Rights Reserved.561 7/98© Vickers, Incorporated 1998

Printed in U.S.A.

Contact us for more information or to locate a Eaton distributor:

888-258-0222 or www.Eatonhydraulics.com.

Eaton Fluid Power14615 Lone Oak RoadEden Prairie, MN 55344-2287Phone: 888 258 0222Fax: 952 974 7722U.S.A. +44 1705 487 612

46 New Lane, HavantHampshire P09 2NBEnglandTelephone: (44) 23 92 486 451Fax: (44) 23 92 487 110

+55 11 6465-8822 +81 3 5462 0647 248 853 1000

Vickers is a leading manufacturer and distributor of engineered power and motioncontrol products and systems for industrial,off-highway, agriculture, aerospace, marineand defense applications worldwide. Nomatter what industry you work in, chances are Vickers does, too.

We meet industries’ demanding fluid power needs with a complete line of products including hydraulic pumps, motors, valves and cylinders; electronic and hydraulic controls; electric motors and drives; filters; and fluid-evaluation products and services.

Vickers innovation is at work all over the world with manufacturing and assembly facilities located across five continents, and more than

300 sales and service centers in 60 countries. Our products and systems aredesigned and manufactured to meet orexceed all global standards. And with the

support of our global network of distributors,we provide complete system design assistance, aftermarket service and genuineVickers parts on a worldwide basis.

VICKERS SYSTEM SOLUTIONS

PRODUCTS

Motor Pumps

Servo and Proportional Valves and Systems

Cartridge Valves, Manifold Systems

Directional, Flow, Relief and Pressure Control Valves

Hydraulic Remote Controls

Filters, Reservoirs and Accessories

Hydraulic Power Packages

Marine Central Control Hydraulic Systems

Piston and Vane Motors–Fixed and Variable

Piston and Vane Pumps–Fixed and Variable

High-Pressure Hydraulic Systems

Hydrostatic Transmissions

High Water-Based Fluid Systems and Components

Hydraulic and Pneumatic Electronic Controls

Servo Motors and Drives

DC Drives

DC Motors

Motion Control Products

Debris Monitoring and Collection Systems

Level Sensing Devices

Electrohydraulic, Hydraulic and Pneumatic Cylinders

MARKETS

Automotive (Car, Truck and Bus)

Construction

Plant Maintenance (All Industries)

Mining AggregatesFarm

Railroads

Materials Handling

Marine (Ships, Boats and Docks)

Logging

Processing Industries

Industrial Plant Equipment

Lift Trucks

Machine Tools

Petroleum Products and Marketing

Entertainment

Special Industrial, Medical, Textile

Monty L Logan