531-2014-2015 Bioniq Katalog en Bez-cen Mail

24
8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 1/24 Product catalog 2014/2015    E   a   s   y   a  n d  

Transcript of 531-2014-2015 Bioniq Katalog en Bez-cen Mail

Page 1: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 1/24

Product catalog 2014/2015

   E  a

  s  y 

 a nd 

e f  f  e c  t  i   v   e   

Page 2: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 2/24

Page 3: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 3/24

3

Implants 11

Soft tissue management 12

Cemented restorations 13

Screw-retained restorations 16

 Attachment-retained restorations 17

Individual prosthetic solutions 18

Instruments 20

     E   a   s   y

 

  a  n d

 

 e f fec t i v  e  

   C  o  n   t  e  n   t  s

Page 4: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 4/24

SCIENTIFIC DOCUMENTATION

 We will be glad to send you a 74-page summa-

ry of selected clinical and experimental studiesdocumenting the long-term clinical perfor-

mance and scientific background of LASAKproducts.

4

 WHY BIONIQ® FROM LASAK?

•  Long-term scientific documentation•  Unique hydrophilic, nanostructured, bioactive titanium surface

•  Exceptionally universal application•  Unique strong and stable Q-Lock connection, see page 7

•  Dual connection – easy fixation of prosthetic frameworks•  Build-in platform shifting – tissue volume and stability 

•  Option of reduced treatment time – safe early and immediate loading•  Instruments for tapered and straight implants for both soft and dense bone in one organizer 

•  One universal prosthetic platform yielding maximum flexibility •  Wide range of prosthetic components ensuring perfect esthetic results

MEDICAL MANUFACTURER WITH A LONG TRADITION

Since 1992, LASAK Ltd., as a research-oriented medical techno-

logy company, has been focusing on the systematic research anddevelopment of bone regeneration materials and implants used indental implantology, neurosurgery, orthopaedics and traumatology.

LASAK offers its clients modern, safe and clinical verified solutionsat the highest technological level.

More than 20 years of experience

Page 5: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 5/24

BioniQ® implant system

5

Esthetics – stability – flexibility 

Q-Lock connection

Prosthetic flexibility 

Color coding

Excellent osseointegration

Hydrophilic BIO-surface

Gentle and fast implant insertion

Conical apex, optimum self-cutting thread

Tissue volume and stability 

Built-in platform shifting

Dual-function connection

Page 6: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 6/24

6

NEW BONE

BIOACTIVE Ti

HYDROPHILIC, BIOACTIVE SURFACE

 As a result of long-term, continuous research into biomaterial – body environment in-

 teractions, LASAK was the first manufacturer of implant system on the market that hasbeen able to offer unique hydrophilic, nanostructured, bioactive surface treatment. The

invention of the BIO-surface has given LASAK a leading global position in the develop-ment of implant surface modifications. LASAK's unique BIO-surface modification speeds up

 the formation of a functional bone-implant interface, thus improving the implant’s secondary

stability in the early healing phase. Thanks to the BIO-surface, the stability dip (often observed innonbioactive surfaces) is eliminated. The outstanding performance of LASAK BIO-surface implants has been

documented for even the most demanding indications.

THE BIONIQ® DENTAL IMPLANT SYSTEM

The BioniQ® implant system includes tapered implants offering easy insertion and

high primary stability in soft bone as well as straight implants for easy positioningin dense bone. The horizontal and vertical set-off of the implant-abutment con-

nection from the bone level, together with the implant mini-threads, contribute to the stability of the marginal bone and soft tissues surrounding the abutment and

provide improved restoration esthetics. The state-of-the-art implant constructionenables safe and precise insertion and optimized load distribution in the bone tis-

sue. Implants are available with a unique hydrophilic, nanostructured, bioactivesurface (BIO). A single system organizer provides instruments for the insertion of

implants with both tapered and straight design.

LASAK´S QUALITY MANAGEMENT SYSTEM

LASAK's manufacturing process is subject to a quality manage-ment system which is in accordance with ISO 9001:2008 and

ISO 13485:2012. All LASAK products bear the CE marking.

15 years of BIO-surface

Page 7: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 7/24

Q-LOCK, THE IMPLANT-ABUTMENT

CONNECTION

 A unique combination of 4 stabilizing components:

• Deep cone ensures stability and tight seal of the connection• Solid hexagon as anti-rotation element

• Reinforcing cylinder – tube in tube• Cone under the screw head

Dual-function connection:

• Internal conical connection for single tooth restorations• External platform for BioCam bridge restorations

Q-Lock connection

The stress of implant and the abutment is examined through the use of strength test with kinematics of chewing. The test consists

of 5 million cycles, where strength of the connection implant-abutment-screw is checked. This amount of cycles corresponds toabout 20 years of the implant lifetime. The given force is likely the maximum of stress force providing the infinite lifetime of the

implant.

Sources: M. Wieland, H. Hornberger, Mechanical testing of fatigue strength, Bone level implant scientific overview, Star- get 2010–1, experimental data of LASAK, Report – Accredited testing laboratory for mechanical tests of ČVUT Praha.

FATIGUE STRENGTH OF THE IMPLANT-ABUTMENT CONNECTION (ISO 14801)

100

120

140

160

180

200

220

240

260

80

  A   s  t  r  a

 

  O  s  s  e

  o   S  p  e  e  d

   T   M

   3.   0   S

  A   s  t  r  a

 

  O  s  s  e

  o   S  p  e  e  d

   T   M

   3.   5   S

  A   s  t  r  a

 

  O  s  s  e

  o   S  p  e  e  d

   T   M

   E   V    3.  6   S

   S  t  r  a  u  m  a

  n  n  ®

    B   L 

   3.   3    N  C

   N  o   b  e   l  A 

  c  t   i  v  e

   T   M 

   3.   5

   N  o   b  e   l   R   e

  p   l  a  c  e

   T   M 

   3.   5   B   i  o  n   i  Q

  ®     S   3.   5

   L   i  m   i   t  o   f   f  a   t   i  g  u  e  s   t  r  e  n

  g   t   h  –   5  m   i   l .  c  y  c   l  e  s   (   N   )

   S  t  r  a  u  m  a  n  n  ®

    B   L 

   3.   3    N  C    R   o

  x  o   l   i  d

   T   M

7

Page 8: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 8/24

Product overview

8

BLUE

PROSTHETIC PLATFORM – QR 

CEMENTED RESTORATIONS

IMPLANTS

ESTHETIC ABUTMENTS

GINGIVA

FORMERS

Indexed components d3.9 d5.2

0.7 mm 2143.071.5 mm 2143.15

3.0 mm 2143.30

Non-indexed components

Bridge components withexternal platformB

0.7 mm 2137.071.5 mm 2137.153.0 mm 2137.30

0.7 mm 2140.071.5 mm 2140.153.0 mm 2140.30

 Angled

Straight

0.7 mm 2139.071.5 mm 2139.15

3.0 mm 2139.30

d3.9/25°

0.7 mm 2138.071.5 mm 2138.15

3.0 mm 2138.30

0.7 mm 2141.071.5 mm 2141.15

3.0 mm 2141.30

d3.9/15° d5.2/15° d5.2/25°

S3.5

T4.0

S4.0

T5.0

S5.0

Narrow

 Wide

Bridge

8 mm 2006.0810 mm 2006.1012 mm 2006.1214 mm 2006.1416 mm 2006.16 2.0 mm 2109.02

4.0 mm 2109.046.0 mm 2109.06

2.0 mm 2110.024.0 mm 2110.046.0 mm 2110.06

2.0 mm 2116.024.0 mm 2116.046.0 mm 2116.06

8 mm 2012.0810 mm 2012.1012 mm 2012.1214 mm 2012.1416 mm 2012.16

6.5 mm 2009.068 mm 2009.08

10 mm 2009.1012 mm 2009.1214 mm 2009.1416 mm 2009.16

8 mm 2020.0810 mm 2020.1012 mm 2020.1214 mm 2020.14

6.5 mm 2017.068 mm 2017.08

10 mm 2017.10

12 mm 2017.1214 mm 2017.14

B

d4.2

d4.2

d3.9

d5.2

d4.9

 ATTACHMENT-RETAINED RESTORATIONS

INDIVIDUAL PROSTHETIC SOLUTIONS

 ATTACHMENTS LOCATOR 

BIOCAM BRIDGES AND

 ABUTMENTS

CAST-ON ABUTMENT

0.5 mm 012841.0 mm 012852.0 mm 012863.0 mm 012874.0 mm 012885.0 mm 01289

6.0 mm 01290

LOCATOR PROCESSING

PACKAGE

08519-2

SCREW-RETAINED RESTORATIONS

SCREW-ON ABUTMENTS

1.0 mm 2148.01

2.0 mm 2148.023.0 mm 2148.034.0 mm 2148.04

2154.00

Straight

2120.00

HEALING CAP

Page 9: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 9/24

Product overview

9

TEMPORARY ABUTMENTS

CERAMIC ABUTMENTS

STANDARDABUTMENTS

d5.0d5.0 d4.0

d4.0

1.0 mm 2127.013.0 mm 2127.03

B

0.7 mm 2146.072.5 mm 2146.25

1.0 mm 2133.012.0 mm 2133.023.0 mm 2133.034.0 mm 2133.04

0.7 mm 2147.072.5 mm 2147.25

 Angled

StraightStraight

1.0 mm 2128.013.0 mm 2128.03

d5.0/15°

IMPRESSION COPING ABUTMENT ANALOG

TEMPORARY ABUTMENTS

08505 08530

LOCATOR REPLACEMENT

INSERTS

blue08529

pink 08527

clear 08524

red08548

orange08915

 green08547

1.0 mm 2127.013.0 mm 2127.03

B

1.0 mm 2128.013.0 mm 2128.03

2710.00 2811.00 2816.00

IMPRESSION COPING BURN-OUT COPING ABUTMENT ANALOG

d4.0 d4.0

OPEN TRAYIMPRESSION POSTS

IMPLANT ANALOG

LAB PIN

2803.00 2833.002704.00

B

2705.00

OPEN TRAY

IMPRESSION POSTS IMPLANT ANALOG LAB PIN

2803.00

2833.00

2704.00

B

2705.00

Page 10: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 10/24

Packaging

10

Shape: S – Straight self-tapping implants  T – Tapered self-tapping implants

h2009.10

          H        0        2    -        2        0        1        8

g0000999999

BioniQ Implant – straight

BioniQ Implantát – straight

BIO S4.0/L10 – straight

BIO S4.0/L10

   B   I   O    S

   4 .   0

   /   L   1   0

 –  s   t  r  a   i  g   h   t

Implant name

Batch number 

Reference number 

Expiration date

Implant specification: Surface Diameter Length Shape

LABEL ON THE OUTSIDE PACKAGING OF THE IMPLANT

g0000000000           H        1        0    -        2        0        1        7

Temporary abutment – bridge

BioniQ

Provizorní pilíř – mostový

h2128.01

QR/B/d4.0/L1

QR/B/d4.0/L1

Y   D

LASAK s.r.o., Českobrodská 1047/46,190 01 Praha 9 – Hloubětín, CZECH REPUBLICM

Q

TC1014

B

B

Prosthetic component name

Implant system name

Component silhouette

Batch number 

Reference number 

Expiration date

Specification: Prosthetic platform

 Anti-rotation/bridgecomponent

Marking of bridge component Width Height

LABEL ON THE OUTSIDE PACKAGING OF THE PROSTHETIC COMPONENT

Marking and packaging of the products

The implants are supplied in two blisters and an outer paper box. The transparent blister allows the visual checking of the product beforeits use. There is a label on the back of the blister with implant information and labels which should be fixed onto the patient documentation.

The paper box has a label, too (see the picture below).The instruments and prosthetic components are supplied decontaminated but not sterile. For an example of the label, see the picture below.

Page 11: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 11/24

Implants

   I  m  p   l  a  n   t  s

11

  Unique hydrophilic, nanostructured bioactive titanium surface

  Built-in platform shifting for tissue volume and stability 

  Conical apex and optimum self-cutting thread enable gentle and fast implant insertion

L8 L10 L12 L14 L16

BIO S3.5 2006.08 2006.10 2006.12 2006.14 2006.16

L8 L10 L12 L14 L16

BIO T4.0 2012.08 2012.10 2012.12 2012.14 2012.16

L6.5 L8 L10 L12 L14 L16

BIO S4.0 2009.06 2009.08 2009.10 2009.12 2009.14 2009.16

L6.5 L8 L10 L12 L14

BIO S5.0 2017.06 2017.08 2017.10 2017.12 2017.14

L8 L10 L12 L14BIO T5.0 2020.08 2020.10 2020.12 2020.14

 A sterile cover screw is supplied with the implant.

S3.5

S5.0

T4.0

T5.0

S4.0

S – Straight self-tapping titanium implants with bioactive surfaceT – Tapered self-tapping titanium implants with bioactive surface

Implants Ø 5.0 mm

Implants Ø 4.0 mm

Implants Ø 3.5 mm

L

Page 12: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 12/24

Gingiva formers

12

QR prosthetic platform

One ultimate prosthetic platform – QR, blue colored – for five types of

implants (S3.5, T4.0, S4.0, T5.0, S5.0).

• Logistic ease• Ease of use and efficiency 

Throughout the catalog the abbreviations d and L are used as follows:d – relates to the actual diameter,L – relates to the actual marked dimension (usually marks length or height).

The gingiva former should extend over the edge of the adapted soft tissue by 1.0 to 2.0 mm, thus preventing the gingiva former becomingcovered by edematous tissue during the post-operative period. The gingiva former's diameter must match the diameter of the abutment to be used in the prosthetic work.

Gingiva formers – narrow 

L2 L4 L6

QR/d4.2 2109.02 2109.04 2109.06

Gingiva formers – wide

L2 L4 L6

QR/d5.2 2110.02 2110.04 2110.06

Gingiva formers – bridge

L2 L4 L6

QR/B/d4.9 2116.02 2116.04 2116.06

  QR platform, non-indexed components B   QR platform, bridge components

L

d

B

Indexed components

Non-indexed components

Bridge components with external platformB

L

d

 S o f t t i s s u e m a n a

 g e m e n t

Page 13: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 13/24

Esthetic abutments for cemented restorations

   C  e  m  e  n   t  e   d  r  e  s   t  o  r  a   t   i  o  n  s

13  QR platform, indexed components QR platform, indexed components B   QR platform, bridge components

L

7.0 mm7.0 mm

L

dd

B

B

  Emergence profile similar to a natural tooth

  Extra robust design

  The height of the abutment shoulder is from 0.7 mm

Esthetic abutments – straight

L0.7 L1.5 L3.0

QR/d3.9 – narrow 2137.07 2137.15 2137.30

QR/d5.2 – wide 2140.07 2140.15 2140.30

Esthetic abutments – angled

L0.7 L1.5 L3.0

QR/d3.9/15o – narrow 2138.07 2138.15 2138.30

QR/d3.9/25o – narrow 2139.07 2139.15 2139.30

QR/d5.2/15o – wide 2141.07 2141.15 2141.30

QR/d5.2/25o – wide 2143.07 2143.15 2143.30

Temporary abutments

L1 L3

QR/d4.0 2127.01 2127.03

QR/B/d4.0 – bridge 2128.01 2128.03

Open tray impression posts

QR 2704.00

QR/B – bridge 2705.00

B

B

Use a new abutment screw for the final abutment tightening.

Tightening torque of abutment screw is 25 Ncm.

Spare abutment screws may be ordered separately under Ref. No. 2103.00.

Spare abutment screws may be ordered separately under Ref. No. 2103.00.

Laboratory components

Implant analog, QR 2803.00

Implant analog, QR, set of 5 pcs. 2803.05

Lab pin, QR 2833.00

Lab pin, QR, set of 5 pcs. 2833.05

Page 14: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 14/24

 C e m e n t e d r e s t o r a t i o n s

14

L

d

  QR platform, indexed components QR platform, non-indexed components

  Allows chair-side selection of the best suitable abutment

  Easy and straightforward impression

  Suitable for single and bridge restorations

STANDARD abutments – straight

L1 L2 L3 L4

QR/d5.0 – wide 2133.01 2133.02 2133.03 2133.04

Healing cap STANDARD

QR/d5.0 – wide, set of 2 pcs. 2118.00

Impression coping STANDARD

QR/d5.0 – wide, set of 2 pcs. 2702.00

Burn-out coping STANDARD

QR/d5.0 – wide, set of 2 pcs. 2809.00

STANDARD abutment analog

QR/d5.0 – wide 2806.00

Spare abutment screws may be ordered separately under Ref. No. 2103.00.

Use a new abutment screw for the final abutment tightening.

Tightening torque of abutment screw is 25 Ncm.

5.0 mm

STANDARD abutmentsfor cemented restorations

Page 15: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 15/24

L

d

B

15

Ceramic abutments for cemented restorations

   C  e  m  e  n   t  e   d  r  e  s   t  o  r  a   t   i  o  n  s

B

  High esthetics

  Easy guidance during cementation

  Restorative versatility 

Ceramic abutments – straight

L0.7 L2.5

QR/d5.0/ZrO2 – wide 2146.07 2146.25

Ceramic abutments – angled

L0.7 L2.5

QR/d5.0/ZrO2/15° – wide 2147.07 2147.25

Open tray impression posts

QR 2704.00

QR/B – bridge 2705.00B

Spare screws for ceramic abutments may be ordered separately under Ref. No. 2105.00. Other than dedicated screws for cera-mic abutments can not be used for their fixation.

Spare screws for ceramic abutments may be ordered separately under Ref. No. 2105.00. Other than dedicated screws for cera-mic abutments can not be used for their fixation.

Temporary abutments

L1 L3

QR/d4.0 2127.01 2127.03

QR/B/d4.0 – bridge 2128.01 2128.03B

Ceramic abutments available in 1Q 2015.

Use a new screw for the final abutment tightening.

Tightening torque of screw for ceramic abutment is 25 Ncm.

  QR platform, indexed components QR platform, non-indexed components B   QR platform, bridge components

7.0 mm

Laboratory components

Implant analog, QR 2803.00

Implant analog, QR, set of 5 pcs. 2803.05

Lab pin, QR 2833.00

Lab pin, QR, set of 5 pcs. 2833.05

Page 16: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 16/24

Screw-On abutments – straight

L1 L2 L3 L4

QR/d4.2 2148.01 2148.02 2148.03 2148.04

Screw-On abutment is not suitable for single tooth restoration.

 Abutment tightening torque is 25 Ncm.

Tightening torque of bridge screw is 15 Ncm.

Bridge screw is delivered with the abutment.* Spare bridge screws may be ordered separately under Ref. No. 2106.00.

Bridge screw is delivered with the healing cap.* Spare bridge screws may be ordered separately under Ref. No. 2106.00.

 Abutment analog for Screw-On abutment – straight

QR/d4.2 2816.00

Impression coping for Screw-On abutment – straight

QR/d4.2 2710.00

  QR platform, non-indexed components

*

Burn-out coping for Screw-On abutment – straight

QR/d4.2 2811.00

Bridge screw is delivered with the burn-out coping.

* Spare bridge screws may be ordered separately under Ref. No. 2106.00.

*

 S c r e w - r e t a i n e d r e s t o r a t i o n s

 Abutments for screw-retainedrestorations

16

Healing cap for Screw-On abutment – straight

QR/d4.2 2120.00

*

  Easily revisable restoration

  One screwdriver fits all – bridge screws as well as all other BioniQ® screws

  Realiable treatment of disparallel implants

L

1.9 mm

Page 17: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 17/24

   A   t   t  a  c   h  m  e  n   t  -  r  e   t  a   i  n  e

   d  r  e  s   t  o  r  a   t   i  o  n  s

LOCATOR attachments

17

  Dual retention

  Self-aligning feature

  Minimal vertical height

LOCATOR attachments

L0.5 L1.0 L2.0 L3.0 L4.0 L5.0 L6.0QR 01284 01285 01286 01287 01288 01289 01290

LOCATOR processing package

LOCATOR processing package, 2 pcs. 08519-2

LOCATOR replacement inserts

blue 680 g, 4 pcs. 08529

pink 1 361 g, 4 pcs 08527

clear 2 268 g, 4 pcs 08524

red 680 g, extended range, 4 pcs. 08548

orange 907 g, extended range, 4 pcs. 08915

 green 1 814 g, extended range, 4 pcs. 08547

Instruments

LOCATOR driver 08913

LOCATOR core tool 08393

The diameter of the LOCATOR abutment is 3.85 mm. In the case of even minimal override of marginal bone to the implant platform makesure to remove it. 1.5 mm of the bronze-colored LOCATOR part should remain supragingival to be able to retain the over-denture.

For implant disparallelity over 10° (max. 20°) use an extended range insert.

1.5 mmL

  QR platform, non-indexed components

Tightening torque of LOCATOR attachment is 25 Ncm.

Impression and laboratory components

LOCATOR impression coping, 4 pcs. 08505

LOCATOR abutment analog, 4 pcs. 08530

Page 18: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 18/24

BioCam bridges and abutments

BioCam technology represents a unique production system of precise superstructures which allows direct fixation in dental implants

 without the use of abutments or other connecting elements. This reduces the number of gaps, between the implant and the superstructure,

 which can be a potential source of bacterial contamination.

* It is delivered with Ti abutment.Custom abutments always contain compatible screws.BioCam bridges and abutments are available for these implant systems: LASAK Impladent ® and BioniQ®, NobelActiveTM, Nobel-Replace®, Straumann® Bone Level and SynOcta® and Astra Tech®.

BioCam custom abutments

Ti/Cr-Co D03

ZrO2* D04

SCAN/CAD D10

Temporary abutments

L1 L3

QR/d4.0 2127.01 2127.03

QR/B/d4.0 – bridge 2128.01 2128.03B

B

  QR platform, indexed components QR platform, non-indexed components B   QR platform, bridge components

Open tray impression posts

QR 2704.00

QR/B – bridge 2705.00B

B

BioCam bridges

Pontic Implant-supported unit

Bridge – Ti, Cr-Co* D01 D02

Bridge – ZrO2** D07 D08

Fixing screw

SCAN/CAD D10

* Fixing screws are not included in the price of superstructure.** Fixing screws are delivered with the Ti abutments and are included in price.

Tightening torque of fixing screw is 25 Ncm.

BioCam abutments LASAK BioniQ®

QR 2159.00QR/B – bridge 2158.00B

B

 I n d i v i d u a l p r o s t h e

 t i c s o l u t i o n s

BioCam

18

Laboratory components

Implant analog, QR 2803.00

Implant analog, QR, set of 5 pcs. 2803.05

Lab pin, QR 2833.00Lab pin, QR, set of 5 pcs. 2833.05

Scanbody, QR 2815.00

Page 19: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 19/24

  QR platform, indexed components

Cast-On

   I  n   d   i  v   i   d  u  a   l  p  r  o  s   t   h  e

   t   i  c  s  o   l  u   t   i  o  n  s

*Available in 4Q 2014.

19

Cast-On abutment, compatible with NobelReplaceTM

NBR RP, indexed 9300.00

NBR WP, indexed 9301.00

NBR NP, indexed 9306.00

Cast-On abutment, compatible with NobelActiveTM

NBA NP, indexed 9312.00NBA RP, indexed 9313.00

Cast-On abutment, compatible with Straumann® SynOcta®

SSO RN, indexed 9302.00

SSO WN, indexed 9303.00

Cast-On abutment, compatible with Straumann® Bone Level

SBL NC, indexed 9310.00

SBL RC, indexed 9311.00

Cast-On abutment, compatible with AstraTech®

 ATS 3.5/4.0, indexed 9304.00

 ATS 4.5/5.0, indexed 9305.00

Customizable prosthetic solutions

The customizable LASAK Cast-On abutment is a universal easy-to-process solution for implant-supported restorations. It consists of

a prefabricated, cobalt-chrome, nickel-free alloy base, a plastic modeling sleeve and a fixing screw. The Cast-On abutment enables

prosthetic restorations even in cases where usual system abutments cannot be used.

Cast-On abutment for LASAK BioniQ®

QR/d3.9* 2154.00

Page 20: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 20/24

Instruments

 I n s t r u m e n t s

20

Drills – standard length

Roundburr 2443.00

Pilot drill d1.5 2446.00

Final drill S2.9 2420.00

Final drill S3.5 2425.00

Final drill S4.0 2430.00

Final drill S5.0 2437.00Final drill T4.0 2435.00

Final drill T5.0 2441.00

Drills – short

Final drill S2.9 – short* 2447.00

Final drill S3.5 – short* 2448.00

Final drill S4.0 – short* 2449.00

Final drill S5.0 – short* 2451.00

Counterbores

Counterbore S3.5 2427.00

Counterbore S4.0/T4.0 2433.00

Counterbore S5.0/T5.0 2439.00

Threadformers

Threadformer S3.5 2426.00

Threadformer S4.0/T4.0 2431.00

Threadformer S5.0/T5.0 2438.00

Paralleling pin

d1.5/d2.3 2417.00

Depth gauges

Depth gauge S2.9 2423.00

Depth gauge S3.5 2428.00

Depth gauge S4.0/T4.0 2434.00Depth gauge S5.0/T5.0 2440.00

  Minimized number of instruments

  Instruments optimized for soft and dense bone preparation

  Instruments for both straight and tapered implants in one cassette

* Short drills available in 1Q 2015.

Page 21: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 21/24

Instruments

   I  n  s   t  r  u  m  e  n   t  s

21

Screwdrivers

Screwdriver – extra short, hex 1.25/L17 2404.00

Screwdriver – short, hex 1.25/L23 2405.00

Screwdriver – long, hex 1.25/L32 2406.00

Screwdriver – mechanical, short, hex 1.25/ISO/L11 2413.11

Screwdriver – mechanical, long, hex 1.25/ISO/L21 2413.21

Trephines

d4.5 2414.3d6.0 5214.3

Drill extension

Drill extension, ISO 2445.00

Insertion wrenches

Unigrip, hex 2.5/ISO/L16 2401.00

Insertion wrench – extra short, hex 2.5/L11 2402.00

Insertion wrench – long, hex 2.5/L24 2403.00

Insertion wrench – mechanical, hex 2.5/ISO 0524.3

Extend driver 

Extend driver 4214.3

Unigrip

The multi-purpose insertion wrench, Unigrip, allows gentle and fast implant insertion into the prepared bone bed, as do the other

BioniQ® insertion wrenches. Beside this Unigrip allows all conventional instruments designed to fit handpiece to be used with the BioniQ® 

ratchet. The apparent hexagon on the Unigrip allows the following up of the position of the anti-rotation element of the implant during the implant insertion.

Page 22: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 22/24

Instruments

 N á s t r o j e

22

 I n s t r u m e n t s

Ratchet

Ratchet 2408.00

Guide wrench

Guide wrench 2410.00

Instrument organizer and cassette

Cassette with organizer for all implant lines 2902.00

Instrument organizer insert for cassette 2903.00

Logically organized instrument cassette

The BioniQ® cassette and instrument organizer helps to intuitively arrange the instruments in the correct sequence. The single organizer

contains instruments for both straight and tapered implants.

Furthermore, it contains all the instruments for prosthetic restoration as well.

Prosthetic set

Prosthetic set(Ratchet, Unigrip, insertion wrenches – extra short andlong, screwdrivers – short and long)

2904.00

Dimension of cassette (including cover) is 295 x 175 x 57 mm.

Radiograph template

Radiograph template for straight and tapered implants 2906.00

Patient demonstration model set

Patient demonstration model set (scale 2.5:1) 1902.00

Page 23: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 23/24

Terms and conditions

23

LASAK Ltd. offers a twenty-year guarantee on all BioniQ® system implants. In the case of implant loss or failure within twenty years of the implantation date, LASAK Ltd. will replace the implant, including cover screw, free of charge, on condition that: the implant was

inserted with the use of original BioniQ® system components, and in accordance with the manufacturer's recommendations, instruc- tions and manuals.

GUARANTEE TERMS AND CONDITIONS

Entitlement to guarantee:

Claims on the guarantee will be honoredproviding original surgical and prostheticcomponents of the BioniQ®  system wereused and the implantation performed in ac-cordance with commonly accepted medicalpractice and adhering to the manufacturer'sinstructions and recommendations as pub-

lished in the manuals and leaflets of LASAKLtd. Implantations with contraindications,as described in the instructions and manu-als of LASAK Ltd., are not covered by the guarantee. The guarantee can be claimedsolely by the medical entity that undertook the implantation, it cannot be claimed by the patient or by any other person. Anymedical entity that is financially in debt toLASAK Ltd. for delivered goods or servicesis, however, excluded from this guarantee.

Exclusions:

This guarantee does not cover implants that are lost:• due to a patient's insufficient oral hygieneand/or due to infections,• as a result of a personal accident or a pa- tient's inappropriate behavior,• due to overloading.

This guarantee does not cover any provi-sional implants.

Changes to and termination of this

guarantee:

LASAK Ltd. reserves the right to makechanges to, or to terminate, this guarantee, without prior notice.

How to make a claim under this guar-

antee:

To make a claim under this guarantee, acompleted form "Record of Failed Implant"should be sent, along with the sterilizedimplant and other components used, to the business address of LASAK Ltd. within30 days of the implant failure.

The conditions stated above are generaland may vary slightly in different countries.The valid conditions of the guarantee for a given country will be provided by the rep-resentative of LASAK Ltd. in each country.

LASAK Ltd. maintains the right to modify, terminate, change specifications or prices without prior notice.

 Astra Tech® and OsseoSpeed® are registered trademarks of Astra Tech AB, Sweden. Straumann® and synOcta® are registered trademarks and RoxolidTM is trademark of Strau-mann Holding AG, Switzerland. NobelActiveTM is a trademark and NobelReplace® is a registered trademark of Nobel Biocare AB, Sweden.

GENERAL BUSINESS TERMS

PRICING – All the above prices are ex-works(EXW) Prague, Czech Republic, Incoterms2000, and do not include any commission, VATor other duties, nor transport or packing costs.The seller reserves the right to change theprices without prior notice.

ORDERING –  Orders may be receivedby writing, Internet, telephone or fax. Anorder is deemed accepted upon confirma- tion by the seller, or upon delivery of the

products, whichever is earlier. In every or-der must be clearly stated the full statutoryname of the buyer, delivery address, speci-fication required, delivery date, the pre-ferred mode of transportation and contactperson with their phone number.

DELIVERY TIME – The delivery time de-pends upon the ordered quantity and has to be agreed individually in advance. Gener-

ally, orders are dispatched by the first avail-able carrier within three working days afterreceipt of the order or payment.

PACKAGING –  Implants are supplied insterile packing. Other components of theimplant system are not supplied sterile, butdecontaminated in sealed transparent flatbags.

PAYMENT TERMS – All listed prices are

net at the account of the seller. Payment terms are payment in advance or confirmed,irrevocable, documentary L/C. If paymentis late the maximum statutory interest rate will be applied to the late amount. Furtherdeliveries may be suspended until fullpayment for any previous unpaid shipmenthas been received. All products remain in the ownership of the seller until the fullinvoiced price is settled.

TRANSPORTATION –  An individuallyagreed mode of transportation is used, usu-ally standard mail to the specified addressof the customer. The transportation costsare charged separately and are not includedin the listed prices.

DELIVERY TERMS AND INSURANCE

The listed prices are ex-works (EXW)Prague, Czech Republic, Incoterms 2000delivery terms. We are prepared to ship

 the requested material to the specified ad-dress based on DDU, CIP or other agreeddelivery terms upon request. All costs thusincurred are charged over and above thelist price of the goods.

Page 24: 531-2014-2015 Bioniq Katalog en Bez-cen Mail

8/10/2019 531-2014-2015 Bioniq Katalog en Bez-cen Mail

http://slidepdf.com/reader/full/531-2014-2015-bioniq-katalog-en-bez-cen-mail 24/24

   E  a

  s  y 

 a nd 

e f  f  e c  t  i   v   e   

LASAK Ltd • Č k b d ká 1047/46 • 190 01 P 9 Hl bě í C h R bl