50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete...

27
STUD WALL HEIGHT CORNER ZONE TYPICAL ZONE 600 600 NOGGINGS AS REQUIRED LAYOUT ELEVATION SCALE 1:20 STUD STUD SPACING VERTICAL BATTENS FIXED TO STUD FRAME AAC ADHESIVE JOINT EXTERNAL FRAME WALL BACK BLOCK 600 BACK BLOCK 50mm LITECRETE VERTICAL BATTENS FIXED TO STUD FRAME 50mm LITECRETE CONNECTION DETAILS A3 ZK 05.10.18 1 of 2 NG F 50mm LITECRETE CONNECTION DETAILS PLAN FIXING DETAIL SCALE 1:20 BACK BLOCK DETAIL SCALE 1:20 50mm LITECRETE COATING SYSTEM AS PER PROJECT SPECIFICATION 250mm OR 2400mm LONG CONTINUOUS BATTENS CONCRETE SLAB BACK BLOCK 16mm - 40mm CAVITY LP-001 PANELS MAY BE SUSPENDED OR MAY SIT ON THE CONCRETE EDGE REBATE AAC ADHESIVE AT VERTICAL AND HORIZONTAL PANEL JOINTS 14-10 x 100mm MP BUGLE HEAD TYPE 17 SCREW FOR STEEL FRAME WITH 20mm AND 40mm BATTEN AND TIMBER FRAME WITH 20mm BATTEN OR 14-10 x150mm HEX HEAD TYPE 17 OR 14-10 x 125mm MP BUGLE HEAD TYPE 17 SCREW FOR TIMBER FRAME WITH 40mm BATTEN 1.1 NOTE: THE BUILDING DESIGNER MUST ALLOW FOR INTERNAL PRESSURES RESULTING FROM DOMINANT OPENINGS WHEN THE BUILDING IS DESIGNED TO AS1170.2 FOR REGIONS C AND D.

Transcript of 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete...

Page 1: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

ST

UD

W

ALL H

EIG

HT

CORNER ZONETYPICAL ZONE

600

600

NOGGINGS AS

REQUIRED

LAYOUT ELEVATION

SCALE 1:20

STUD

STUD SPACING

VERTICAL BATTENS FIXED TO

STUD FRAME

AAC ADHESIVE JOINT

EXTERNAL FRAME WALL

BACK BLOCK

600

BACK BLOCK

50mm LITECRETE

VERTICAL BATTENS

FIXED TO STUD FRAME

50mm LITECRETE CONNECTION DETAILS

A3ZK 05.10.18

1 of 2 NGF

50mm LITECRETE CONNECTION DETAILS

PLAN FIXING DETAIL

SCALE 1:20

BACK BLOCK DETAIL

SCALE 1:20

50mm LITECRETE

COATING SYSTEM AS PER

PROJECT SPECIFICATION

250mm OR 2400mm LONG

CONTINUOUS BATTENS

CONCRETE SLAB

BACK BLOCK

16mm - 40mm CAVITY

LP-001

PANELS MAY BE

SUSPENDED OR MAY

SIT ON THE CONCRETE

EDGE REBATE

AAC ADHESIVE AT VERTICAL AND

HORIZONTAL PANEL JOINTS

14-10 x 100mm MP BUGLE HEAD

TYPE 17 SCREW FOR STEEL

FRAME WITH 20mm AND 40mm

BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10

x150mm HEX HEAD TYPE 17 OR

14-10 x 125mm MP BUGLE HEAD

TYPE 17 SCREW FOR TIMBER

FRAME WITH 40mm BATTEN

1.1

NOTE: THE BUILDING DESIGNER MUST ALLOW FOR INTERNAL PRESSURES RESULTING FROM

DOMINANT OPENINGS WHEN THE BUILDING IS DESIGNED TO AS1170.2 FOR REGIONS C AND D.

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DRAWING REFERENCE
AutoCAD SHX Text
SCALE
Page 2: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

TYPICAL FIXING DETAIL - PLAN VIEW

SCALE: 1:5

50mm LITECRETE COMPONENTS AND FIXING DETAILS

50mm LITECRETE

WALL WRAP (OPTIONAL)

STUD

INTERNAL LINING

INTERNAL LINING

50 20-40

COATING SYSTEM AS PER

PROJECT SPECIFICATION

AAC ADHESIVE JOINT

50mm LITECRETE

TYPICAL FIXING DETAIL - SIDE VIEW

SCALE: 1:5

250mm OR 2400mm LONG

CONTINUOUS BATTENS

250mm OR 2400mm LONG

CONTINUOUS BATTENS

50mm LITECRETE FIXING DETAILS

A3ZK

24.10.18

NGF

16mm - 40mm CAVITY

16mm - 40mm CAVITY

REFER TO TABLE 1 FOR SCREW

FIXING DETAILS

SYSTEMCOMPONENT COMPONENT DETAILS NOTES

LITECRETE 2000mm x 600mm x 50mm

BATTENS/ BACK

BLOCKS

20mm TIMBER CAVITY BATTEN

H3 TREATED TIMBER. 35x20x(250mm OR

CONTINUOUS) OR 35x40x(250MM OR

CONTINUOUS)40mm TIMBER CAVITY BATTEN

20mm STEEL CAVITY BATTEN

0.42 THICK GALVANISED STEEL. 35x20x(250mm

OR CONTINUOUS) OR 35x40x(250mm OR

CONTINUOUS)

40mm STEEL CAVITY BATTEN

RONDO 301

0.42 THICK GALVANISED STEEL. F

Y

=550MPa.

COATING CLASS AZ150.

RONDO 303

RONDO 310

0.55 THICK GALVANISED STEEL. F

Y

=270MPa.

COATING CLASS Z275.

24mm PERFORATED STEEL TOP HAT

0.42 THICK GALVANISED STEEL. F

Y

=550MPa.

COATING CLASS AZ150.

35mm PERFORATED STEEL TOP HAT

0.55 THICK GALVANISED STEEL. F

Y

=270MPa.

COATING CLASS Z275.

20mm EXPANDED POLYSTYRENE (EPS) BATTEN

VERY HIGH DENSITY (CLASS VH) - 28kg/m3

DENSITY. 35x20x(250mm OR CONTINUOUS) OR

35x40x(250mm OR CONTINUOUS).

40mm EXPANDED POLYSTYRENE (EPS) BATTEN

NAILS TO FIX

TIMBER BATTENS

TO TIMBER

FRAME

2.87mm x 50mm GALVANISED NAILS – 20mm TIMBER BATTENS

TO TIMBER FRAME

2 NAILS PER 250mm LONG BATTEN OR 2 NAILS

PER 600mm HEIGHT FOR CONTINUOUS BATTENS

3.05mm x 75mm GALVANISED FRAMING NAILS – 40mm TIMBER

BATTENS TO TIMBER FRAME

2 NAILS PER 250mm LONG BATTEN OR 2 NAILS

PER 600mm HEIGHT FOR CONTINUOUS BATTENS

SCREWS TO FIX

TIMBER BATTENS

TO STEEL FRAME

12x40mm GALVANISED DRILL POINT COUNTERSUNK

SCREWS – 20mm TIMBER BATTENS TO STEEL FRAME

2 SCREWS PER BATTEN OR 2 SCREWS PER

600mm HEIGHT FOR CONTINUOUS BATTENS

12x60mm GALVANISED DRILL POINT COUNTERSUNK

SCREWS – 40mm TIMBER BATTENS TO STEEL FRAME

TEMPORARY

FIXINGS TO FIX

BATTENS TO

FRAME

LIQUID NAILS OR MAXBOND ADHESIVE TO TEMPORARILY FIX

EPS BATTENS TO FRAME OR BUILDING WRAP

12-11x35mm HEX HEAD TYPE 17 SCREWS – TEMPORARILY FIX

STEEL BATTENS TO TIMBER FRAMES

10-16x16mm HEX HEAD TEK SCREWS – TEMPORARILY FIX

STEEL BATTENS TO STEEL FRAMES

SCREWS TO FIX

50mm LITECRETE

TO BATTENS

14-10x100mm MP BUGLE HEAD TYPE 17 SCREWS – FIX PANELS

THROUGH 20mm BATTENS INTO THE TIMBER FRAME OR TO

STEEL FRAME WITH 20mm OR 40mm BATTENS

14-10x150mm HEX HEAD TYPE 17 SCREWS OR 14-10x125mm MP

BUGLE HEAD TYPE 17 SCREWS – FIX PANELS THROUGH 40mm

BATTENS INTO THE TIMBER FRAME

TABLE 1

REFER TO TABLE 1 FOR SCREW

FIXING DETAILS

REFER TO TABLE 1 FOR SCREW

FIXING DETAILS

ULS WIND PRESSURE (KPA) STUD SPACING (MM) NUMBER OF SCREWS PER 600MM WIDEPANEL PER STUD

WIND ZONE AWAY FROMCORNERS

WITHIN 1200MM OFCORNERS

AWAY FROMCORNERS

WITHIN 1200MM OFCORNERS

AWAY FROMCORNERS

WITHIN 1200MM OFCORNERS

N2, N3, C1 1.05 / -0.98 -1.95 900 600 2 2

N4, C2 1.56 / -1.45 -2.9 600 600 2 3

N5, C3 2.3 / -2.14 -4.27 450 450 3 3

TABLE 2

1.2 2 of 2

*MINIMUM SCREW EMBEDMENT OF 25mm FOR SCREWS FIXING PANELS INTO TIMBER FRAME

LP-002

NOTE: THE BUILDING DESIGNER MUST ALLOW FOR INTERNAL PRESSURES RESULTING FROM

DOMINANT OPENINGS WHEN THE BUILDING IS DESIGNED TO AS1170.2 FOR REGIONS C AND D.

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 3: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

50mm LITECRETE TOTAL SYSTEM R-VALUES

50mm LITECRETE TOTAL SYSTEM R-VALUES

A3ZK

NG

C1.3

LP-003

3 of 27

STUD SPACING

CROSS SECTION DETAIL

SCALE 1:5

50mm LITECRETES

COATING SYSTEM

AS PER PROJECT

SPECIFICATION

16mm - 40mm CAVITY

DESCRIPTION

TOTAL R-VALUE

m

2

.K/W

INTERNAL LINING

STUD

FRAME

INSULATION BATTS WALL WRAP

BATTEN

CAVITY

LITECRETE SUMMER WINTER

10mm GYPROCK

PLASTERBOARD

PLUS (5.7 kg/m

2

density)

64mm

STUD

FRAME

NONE NONE

20mm

50mm

LITECRETE

0.76 0.74

NONE POLYAIR PERFORMA 4.0 XHD 2.10 1.92

70mm BRADFORD SOUNDSCREEN BATTS R2.0 THERMOSEAL WALL WRAP XP 3.30 3.05

70mm BRADFORD SOUNDSCREEN BATTS R2.0 ENVIROSEAL PROCTORWRAP RW 2.83 2.63

NONE NONE

40mm

0.77 0.74

NONE POLYAIR PERFORMA 4.0 XHD 2.22 1.99

70mm BRADFORD SOUNDSCREEN BATTS R2.0 THERMOSEAL WALL WRAP XP 3.35 3.09

70mm BRADFORD SOUNDSCREEN BATTS R2.0 ENVIROSEAL PROCTORWRAP RW 2.84 2.64

70mm

STUD

FRAME

NONE NONE

20mm

0.77 0.74

NONE POLYAIR PERFORMA 4.0 XHD 2.10 1.92

70mm BRADFORD SOUNDSCREEN BATTS R2.0 THERMOSEAL WALL WRAP XP 3.45 3.19

70mm BRADFORD SOUNDSCREEN BATTS R2.0 ENVIROSEAL PROCTORWRAP RW 2.98 2.76

NONE NONE

40mm

0.77 0.74

NONE POLYAIR PERFORMA 4.0 XHD 2.22 1.99

70mm BRADFORD SOUNDSCREEN BATTS R2.0 THERMOSEAL WALL WRAP XP 3.50 3.22

70mm BRADFORD SOUNDSCREEN BATTS R2.0 ENVIROSEAL PROCTORWRAP RW 2.98 2.77

90mm

OR

92mm

STUD

FRAME

NONE NONE

20mm

0.77 0.74

NONE POLYAIR PERFORMA 4.0 XHD 2.15 1.94

90mm BRADFORD GOLD WALL BATTS R2.0 THERMOSEAL WALL WRAP XP 3.45 3.19

90mm BRADFORD GOLD WALL BATTS R2.5 ENVIROSEAL PROCTORWRAP RW 3.51 3.24

90mm BRADFORD POLYMAX WALL BATT R2.5 ENVIROSEAL PROCTORWRAP RW 3.51 3.24

90mm BRADFORD GOLD WALL BATTS R2.7 ENVIROSEAL PROCTORWRAP RW 3.72 3.43

NONE NONE

40mm

0.77 0.74

NONE POLYAIR PERFORMA 4.0 XHD 2.27 2.01

90mm BRADFORD GOLD WALL BATTS R2.0 THERMOSEAL WALL WRAP XP 3.50 3.22

90mm BRADFORD GOLD WALL BATTS R2.5 ENVIROSEAL PROCTORWRAP RW 3.51 3.25

90mm BRADFORD POLYMAX WALL BATT R2.5 ENVIROSEAL PROCTORWRAP RW 3.51 3.25

90mm BRADFORD GOLD WALL BATTS R2.7 ENVIROSEAL PROCTORWRAP RW 3.72 3.44

TABLE 3

NOTE:

6mm SKIM RENDER HAS BEEN INCLUDED IN TOTAL R-VALUE OF THE WALL SYSTEMS PROVIDED IN TABLE 3.

INSULATION BATTS

AS PER TABLE 3

WALL WRAP AS

PER TABLE 3

10mm PLASTERBOARD PLUS

PERFORMANCE CRITERIA RECOMMENDED WALL WRAP REFLECTIVE OR NON-REFLECTIVE

VAPOUR BARRIER*

POLAIR PERFORMA4.0 XHD REFLECTIVE DOUBLE-SIDED

THERMOSEAL WALL WRAP XP REFLECTIVE SINGLE-SIDED

VAPOUR PERMEABLE** ENVIROSEAL PROCTORWRAP RW NON-REFLECTIVE

TABLE 4

NOTE:

*VAPOUR BARRIER PRODUCTS ARE NOT RECOMMNEDED FOR CONDENSATION CONTROL IN COLDER CLIMATE ZONE IN CONJUCTION WITH HIGH INSULATION R-VALUES.

**VAPOUR PERMEABLE PRODUCTS ARE NOT RECOMMENDED FOR USE IN TROPICAL CLIMATE ZONES.

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
DRAWING REFERENCE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
Page 4: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

50mm LITECRETE BASE OF WALL DETAIL (OPTION 1)

NOTE: FOR RETROFIT SCENARIOS, EXISTING FRAME AND FOOTINGS MUST BE

INSPECTED AND APPROVED FOR 50mm LITECRETE APPLICATION BY PROJECT

ENGINEER. ALL FRAMES SHALL BE APPROVED BY PROJECT ENGINEER FOR

SUSPENDED 50mm LITECRETE APPLICATION.

20-40

FOOTING JUNCTION - SUPPORTED ON A BASE

SCALE: 1:5

COATING SYSTEM AS PER

PROJECT SPECIFICATION

AAC ADHESIVE JOINT

BASE OF PANEL TO GROUND LEVEL

DISTANCE AS PER BCA REQUIREMENTS

MAX. 25mm

OVERHANG PANEL

DPC

250mm OR 2400mm LONG

CONTINUOUS BATTENS

EXTERNAL FRAME

50mm LITECRETE

OPTIONAL WALL WRAP TO LAP

OVER FLASHING

REINFORCED

CONCRETE SLAB

THIS SLAB EDGE DETAIL DOES NOT COMPLY

WITH THE TERMITE VISIBLE INSPECTION ZONE

REQUIREMENTS ALTERNATE TERMITE

MANAGEMENT SYSTEMS MUST BE USED WHEN

SELECTING THIS DETAIL. IT IS THE

RESPONSIBILITY OF THE BUILDER TO PROVIDE

A SUITABLE PHYSICAL OR CHEMICAL BARRIER

IN ACCORDANCE WITH AS3660.

50

FGL

250mm OR 2400mm LONG

CONTINUOUS BATTENS

50mm LITECRETE BASE OF WALL DETAIL (OPTION 1)

A3ZK

NGB

16mm - 40mm CAVITY

14-10 x 100mm MP BUGLE HEAD

TYPE 17 SCREW FOR STEEL

FRAME WITH 20mm AND 40mm

BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10

x150mm HEX HEAD TYPE 17 OR

14-10 x 125mm MP BUGLE HEAD

TYPE 17 SCREW FOR TIMBER

FRAME WITH 40mm BATTEN

2.1

LP-004

4 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 5: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

FGL

50-90mm SOLID

MASONRY COURSE

DPC

50mm LITECRETE BASE OF WALL DETAIL (OPTION 2)

FOOTING JUNCTION - SUPPORTED ON A BASE (WITH BRICK COURSE)

SCALE: 1:5

REINFORCED

CONCRETE SLAB

250mm OR 2400mm LONG

CONTINUOUS BATTENS

EXTERNAL FRAME

50mm LITECRETE

OPTIONAL WALL WRAP TO

LAP OVER FLASHING

COATING SYSTEM AS PER

PROJECT SPECIFICATION

50mm LITECRETE BASE OF WALL DETAIL (OPTION 2)

A3ZK

NG

16mm - 40mm CAVITY

14-10 x 100mm MP BUGLE HEAD

TYPE 17 SCREW FOR STEEL

FRAME WITH 20mm AND 40mm

BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10

x150mm HEX HEAD TYPE 17 OR

14-10 x 125mm MP BUGLE HEAD

TYPE 17 SCREW FOR TIMBER

FRAME WITH 40mm BATTEN

2.2 B

LP-005

5 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 6: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

50mm LITECRETE BASE OF WALL DETAIL (OPTION 3)

NOTE: FOR RETROFIT SCENARIOS, EXISTING FRAME AND FOOTINGS MUST BE

INSPECTED AND APPROVED FOR 50mm LITECRETE APPLICATION BY PROJECT

ENGINEER. ALL FRAMES SHALL BE APPROVED BY PROJECT ENGINEER FOR

SUSPENDED 50mm LITECRETE APPLICATION.

20-40

FOOTING JUNCTION - SUSPENDED FROM FRAME

SCALE: 1:5

CAVITY CLOSER

REINFORCED

CONCRETE SLAB

THIS SLAB EDGE DETAIL DOES NOT COMPLY

WITH THE TERMITE VISIBLE INSPECTION ZONE

REQUIREMENTS ALTERNATE TERMITE

MANAGEMENT SYSTEMS MUST BE USED WHEN

SELECTING THIS DETAIL. IT IS THE

RESPONSIBILITY OF THE BUILDER TO PROVIDE

A SUITABLE PHYSICAL OR CHEMICAL BARRIER

IN ACCORDANCE WITH AS3660.

50

FGL

COATING SYSTEM AS PER

PROJECT SPECIFICATION

AAC ADHESIVE JOINT

250mm OR 2400mm LONG

CONTINUOUS BATTENS

EXTERNAL FRAME

50mm LITECRETE

OPTIONAL WALL WRAP TO

LAP OVER FLASHING

250mm OR 2400mm LONG

CONTINUOUS BATTENS

50mm LITECRETE BASE OF WALL DETAIL (OPTION 3)

A3ZK

NG

16mm - 40mm CAVITY

14-10 x 100mm MP BUGLE HEAD

TYPE 17 SCREW FOR STEEL

FRAME WITH 20mm AND 40mm

BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10

x150mm HEX HEAD TYPE 17 OR

14-10 x 125mm MP BUGLE HEAD

TYPE 17 SCREW FOR TIMBER

FRAME WITH 40mm BATTEN

BASE OF PANEL TO GROUND LEVEL

DISTANCE AS PER BCA REQUIREMENTS

2.3 B

LP-006

6 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 7: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

50mm LITECRETE BASE DETAIL - SUSPENDED

BASE DETAIL - SUSPENDED FLOOR (EXPOSED SUBFLOOR)

SCALE: 1:5

50mm LITECRETE MAKEOVER EXISTING STRUCTURE

EXISTING CLAD TIMBER

FRAMED EXTERNAL WALLS

EXISTING FLOORING SYSTEM

COATING SYSTEM AS PER

PROJECT SPECIFICATION

EXISTING CLADDING

50mm LITECRETE

VERMIN BARRIER/ CAVITY CLOSER

EXISTING PIERS/STUMPS

NOTE: FOR RETROFIT SCENARIOS, EXISTING FRAME AND FOOTINGS MUST BE

INSPECTED AND APPROVED FOR 50mm LITECRETE APPLICATION BY PROJECT

ENGINEER. ALL FRAMES SHALL BE APPROVED BY PROJECT ENGINEER FOR

SUSPENDED 50mm LITECRETE APPLICATION.

250mm OR 2400mm LONG

CONTINUOUS BATTENS

50mm LITECRETE BASE DETAIL - SUSPENDED

A3ZK

NG

16mm - 40mm CAVITY

14-10 x 100mm MP BUGLE HEAD

TYPE 17 SCREW FOR STEEL

FRAME WITH 20mm AND 40mm

BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10

x150mm HEX HEAD TYPE 17 OR

14-10 x 125mm MP BUGLE HEAD

TYPE 17 SCREW FOR TIMBER

FRAME WITH 40mm BATTEN

2.4 B

LP-007

7 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 8: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

50mm LITECRETE BASE DETAIL - SUSPENDED

BASE DETAIL - SUSPENDED FLOOR (HIDDEN SUBFLOOR)

SCALE: 1:5

EXISTING CLAD TIMBER

FRAMED EXTERNAL WALLS

BRACKETS FIXED TO STUDS

EXISTING FLOORING SYSTEM

COATING SYSTEM AS PER

PROJECT SPECIFICATION

AAC ADHESIVE JOINT

EXISTING CLADDING

50mm LITECRETE

100m

m

EXISTING PIERS/STUMPS

20m

m

CLE

AR

10mm MIN. GAP REFER

TO ENGINEERS ADVICE

ANT CAPPING OR EQUIVALENT

TERMITE SYSTEM

10mm SOLID PACKER

CONTROL JOINT

ANGLE STRUCTURE TO SUIT

ENGINEERS REQUIREMENTS

NEW LOAD BEARING BEAM OR

FRAME SUPPORTED OFF EXISTING

PIERS BY STRUCTURAL ENGINEER

(FACE TO FACE ALIGN WITH

EXISTING FACADE)

NOTE: FOR RETROFIT SCENARIOS, EXISTING FRAME AND FOOTINGS MUST BE

INSPECTED AND APPROVED FOR 50mm LITECRETE APPLICATION BY PROJECT

ENGINEER. ALL FRAMES SHALL BE APPROVED BY PROJECT ENGINEER FOR

SUSPENDED 50mm LITECRETE APPLICATION.

50mm LITECRETE MAKEOVER EXISTING STRUCTURE

BASE DETAIL - SUSPENDED FLOOR - PIER CONNECTION

SCALE: 1:5

120m

m M

IN

.

EXISTING

PIERS/STUMPS

GALVANISED ANGLE TO

ENGINEERS DETAIL

AAC ADHESIVE

JOINT

50mm LITECRETE BASE DETAIL (SUSPENDED)

A3ZK

NG

16mm - 40mm CAVITY

14-10 x 100mm MP BUGLE HEAD

TYPE 17 SCREW FOR STEEL FRAME

WITH 20mm AND 40mm BATTEN AND

TIMBER FRAME WITH 20mm BATTEN

OR 14-10 x150mm HEX HEAD TYPE

17 OR 14-10 x 125mm MP BUGLE

HEAD TYPE 17 SCREW FOR TIMBER

FRAME WITH 40mm BATTEN

14-10 x 100mm MP BUGLE HEAD

TYPE 17 SCREW FOR STEEL FRAME

WITH 20mm AND 40mm BATTEN AND

TIMBER FRAME WITH 20mm BATTEN

OR 14-10 x150mm HEX HEAD TYPE

17 OR 14-10 x 125mm MP BUGLE

HEAD TYPE 17 SCREW FOR TIMBER

FRAME WITH 40mm BATTEN

VERMIN BARRIER/ CAVITY CLOSER

2.5 B

LP-008

8 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 9: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

50mm LITECRETE VERTICAL CONTROL JOINTS

STUD SPACING

50mm LITECRETE

EXTERNAL STUD FRAME

10mm NOM.

300mm MAX.

PAINTABLE EXTERNAL

GRADE POLYURETHANE

SEALANT AND BACKING ROD

300mm MAX.

TYPICAL VERTICAL CONTROL JOINTS

SCALE: 1:5

50mm LITECRETE

EXTERNAL STUD FRAME

PAINTABLE EXTERNAL

GRADE POLYURETHANE

SEALANT AND BACKING ROD

10mm NOM.

50mm LITECRETE VERTICAL JOINTS

A3ZK

NG

16mm - 40mm CAVITY

16mm - 40mm CAVITY

14-10 x 100mm MP BUGLE HEAD TYPE 17

SCREW FOR STEEL FRAME WITH 20mm

AND 40mm BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10 x150mm HEX

HEAD TYPE 17 OR 14-10 x 125mm MP

BUGLE HEAD TYPE 17 SCREW FOR

TIMBER FRAME WITH 40mm BATTEN

14-10 x 100mm MP BUGLE HEAD TYPE 17

SCREW FOR STEEL FRAME WITH 20mm

AND 40mm BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10 x150mm HEX

HEAD TYPE 17 OR 14-10 x 125mm MP

BUGLE HEAD TYPE 17 SCREW FOR

TIMBER FRAME WITH 40mm BATTEN

250mm OR 2400mm LONG

CONTINUOUS BATTENS

250mm OR 2400mm LONG

CONTINUOUS BATTENS

3.1 B

LP-009

9 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 10: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

50mm LITECRETE EXTERNAL CORNER JOINTS

EXTERNAL CORNER

SCALE: 1:5

50mm LITECRETE

EXTERNAL FRAME

NOM.10mm

COATING SYSTEM AS PER

PROJECT SPECIFICATION

PAINTABLE EXTERNAL GRADE

POLYURETHANE SEALANT AND

BACKING ROD

COATING SYSTEM AS PER

PROJECT SPECIFICATION

250mm OR 2400mm LONG

CONTINUOUS BATTENS

250mm OR 2400mm LONG

CONTINUOUS BATTENS

50mm LITECRETE EXTERNAL CORNER JOINTS

A3ZK

NG

16mm - 40mm CAVITY

16mm - 40mm CAVITY

14-10 x 100mm MP BUGLE HEAD

TYPE 17 SCREW FOR STEEL FRAME

WITH 20mm AND 40mm BATTEN AND

TIMBER FRAME WITH 20mm BATTEN

OR 14-10 x150mm HEX HEAD TYPE 17

OR 14-10 x 125mm MP BUGLE HEAD

TYPE 17 SCREW FOR TIMBER

FRAME WITH 40mm BATTEN

14-10 x 100mm MP BUGLE HEAD

TYPE 17 SCREW FOR STEEL

FRAME WITH 20mm AND 40mm

BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10

x150mm HEX HEAD TYPE 17 OR

14-10 x 125mm MP BUGLE HEAD

TYPE 17 SCREW FOR TIMBER

FRAME WITH 40mm BATTEN

3.2 B

LP-010

10 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 11: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

50mm LITECRETE INTERNAL CORNER JOINTS

INTERNAL CORNER

SCALE: 1:5

50mm LITECRETE

EXTERNAL FRAME

SCALE: 1:10

EXTERNAL FRAME

COATING SYSTEM AS PER

PROJECT SPECIFICATION

PAINTABLE EXTERNAL GRADE

POLYURETHANE SEALANT AND

BACKING ROD

PAINTABLE EXTERNAL GRADE

POLYURETHANE SEALANT AND

BACKING ROD

75 x 50 x 1.2mm BMT INTERNAL

CORNER ANGLE

75 x 50 x 1.2mm BMT

INTERNAL CORNER ANGLE

50mm LITECRETE

EXTERNAL FRAME

250mm OR 2400mm LONG

CONTINUOUS BATTENS

250mm OR 2400mm LONG

CONTINUOUS BATTENS

50mm LITECRETE INTERNAL CORNER JOINTS

A3ZK

NG

16mm - 40mm CAVITY

16mm - 40mm CAVITY

14-10 x 100mm MP BUGLE HEAD

TYPE 17 SCREW FOR STEEL FRAME

WITH 20mm AND 40mm BATTEN AND

TIMBER FRAME WITH 20mm BATTEN

OR 14-10 x150mm HEX HEAD TYPE

17 OR 14-10 x 125mm MP BUGLE

HEAD TYPE 17 SCREW FOR TIMBER

FRAME WITH 40mm BATTEN

250mm OR 2400mm LONG

CONTINUOUS BATTENS

14-10 x 100mm MP BUGLE HEAD

TYPE 17 SCREW FOR STEEL FRAME

WITH 20mm AND 40mm BATTEN AND

TIMBER FRAME WITH 20mm BATTEN

OR 14-10 x150mm HEX HEAD TYPE

17 OR 14-10 x 125mm MP BUGLE

HEAD TYPE 17 SCREW FOR TIMBER

FRAME WITH 40mm BATTEN

14-10 x 100mm MP BUGLE

HEAD TYPE 17 SCREW FOR

STEEL FRAME WITH 20mm

AND 40mm BATTEN AND

TIMBER FRAME WITH 20mm

BATTEN OR 14-10 x150mm

HEX HEAD TYPE 17 OR 14-10

x 125mm MP BUGLE HEAD

TYPE 17 SCREW FOR

TIMBER FRAME WITH 40mm

BATTEN

3.3 B

LP-011

11 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 12: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

50mm LITECRETE HORIZONTAL CONTROL JOINT DETAILS

TYPICAL HORIZONTAL CONTROL JOINT -

ENGINEERED TIMBER OR STEEL STUD FRAME

SCALE 1:5

COATING SYSTEM AS PER

PROJECT SPECIFICATION

CONTINUOUS PACKER

ALONG THE WALL

50mm LITECRETE

50mm LITECRETE

SUITABLE ACOUSTIC AND/ OR

FIRE RATED SEALANT OVER

BACKING ROD

ENGINEERED TIMBER OR

STEEL JOIST

NOMINAL 10mm

ABLEFLEX OR BACKING ROD

TYPICAL HORIZONTAL CONTROL JOINT -

ENGINEERED TIMBER OR STEEL STUD FRAME

SCALE 1:5

CONTINUOUS PACKER

ALONG THE WALL

50mm LITECRETE

50mm LITECRETE

SUITABLE ACOUSTIC AND/ OR

FIRE RATED SEALANT OVER

BACKING ROD

ENGINEERED TIMBER

OR STEEL JOIST

NOMINAL 10mm

ABLEFLEX OR BACKING ROD

DEFLECTION GAP AS PER

PROJECT SPECIFICATION

DRIP GROOVE IN

COATING

50 x 50mm POLYURETHANE

AIR SEAL OPEN CELL FOAM

FEATURE MOULDING FIXED

TO TOP PANEL

TEMPORARY TIMBER PACKER DURING

CONSTRUCTION ONLY REMOVE ON

COMPLETION (TYPICALLY 35mm)

PAINTABLE EXTERNAL

GRADE POLYURETHANE

SEALANT AND BACKING ROD

10mm SOLID PACKER

50mm LITECRETE HORIZONTAL CONTROL JOINT DETAIL

A3ZK

NG

16mm - 40mm CAVITY

COATING SYSTEM AS PER

PROJECT SPECIFICATION

16mm - 40mm CAVITY

14-10 x 100mm MP BUGLE HEAD

TYPE 17 SCREW FOR STEEL

FRAME WITH 20mm AND 40mm

BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10

x150mm HEX HEAD TYPE 17 OR

14-10 x 125mm MP BUGLE HEAD

TYPE 17 SCREW FOR TIMBER

FRAME WITH 40mm BATTEN

14-10 x 100mm MP BUGLE

HEAD TYPE 17 SCREW

FOR STEEL FRAME WITH

20mm AND 40mm BATTEN

AND TIMBER FRAME WITH

20mm BATTEN OR 14-10

x150mm HEX HEAD TYPE

17 OR 14-10 x 125mm MP

BUGLE HEAD TYPE 17

SCREW FOR TIMBER

FRAME WITH 40mm

BATTEN

3.4 B

LP-012

12 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 13: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

CONTROL JOINTS AT DOOR OPENINGS

SCALE: 1:20

50mm LITECRETE CONTROL JOINTS AT DOOR OPENINGS

CONTROL JOINT EITHER

SIDE OF DOOR

MIN. 270mm

≤ PANEL LENGTH

50mm LITECRETE CONTROL JOINTS

A3ZK

NGA

DOOR OPENING

NOTE:

1. VERTICAL CONTROL JOINTS ARE REQUIRED AT MAXIMUM 6m CENTRES.

2. VERTICAL CONTROL JOINTS ARE REQUIRED AT ABOVE AND BELOW ALL DOORS.

3. VERTICAL CONTROL JOINTS ARE REQUIRED ABOVE AND BELOW WINDOW OPENINGS WHEN EXCEEDS 6m.

4. VERTICAL CONTROL JOINTS ARE REQUIRED AT EXTERNAL AND INTERNAL CORNERS.

3.5

LP-013

13 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 14: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

50mm LITECRETE CONTROL JOINT AT WINDOWS

CONTROL JOINT

CUT ROW OF PANELS TO SUIT

WINDOW HEIGHT (MIN. 270mm)

MIN. 200mm

NOTCH OR JOINT

CONTROL JOINT AT WINDOW

SCALE: 1:20

50mm LITECRETE CONTROL JOINT AT WINDOWS

A3ZK

NGA

NOTE:

1. VERTICAL CONTROL JOINTS ARE REQUIRED AT MAXIMUM 6m CENTRES.

2. VERTICAL CONTROL JOINTS ARE REQUIRED AT ABOVE AND BELOW ALL DOORS.

3. VERTICAL CONTROL JOINTS ARE REQUIRED ABOVE AND BELOW WINDOW OPENINGS WHEN EXCEEDS 6m.

4. VERTICAL CONTROL JOINTS ARE REQUIRED AT EXTERNAL AND INTERNAL CORNERS.

3.6

LP-014

14 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 15: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

PANEL OVER WINDOW (OPTION 1)

SCALE: 1:20

50mm LITECRETE OVER OPENINGS (OPTION 1)

PANEL OVER OPENING

CUT ROW OF PANELS TO SUIT

WINDOW HEIGHT (MIN. 270mm)

NOTCH OR JOINT

NOTCH OR JOINT

MIN. 270 mm

50mm LITECRETE OVER OPENINGS (OPTION 1)

A3ZK

NGA

MIN. 270mm

NOTE:

1. VERTICAL CONTROL JOINTS ARE REQUIRED AT MAXIMUM 6m CENTRES.

2. VERTICAL CONTROL JOINTS ARE REQUIRED AT ABOVE AND BELOW ALL DOORS.

3. VERTICAL CONTROL JOINTS ARE REQUIRED ABOVE AND BELOW WINDOW OPENINGS WHEN EXCEEDS 6m.

4. VERTICAL CONTROL JOINTS ARE REQUIRED AT EXTERNAL AND INTERNAL CORNERS.

3.7

LP-015

15 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 16: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

50mm LITECRETE OVER OPENINGS (OPTION 2)

PANEL OVER WINDOW (OPTION 2)

SCALE: 1:20

PANEL OVER OPENING

MIN.

200mm

MIN.

200mm

NOTCH OR JOINTNOTCH OR JOINT

50mm LITECRETE OVER OPENINGS (OPTION 2)

A3ZK

NGA

MIN. 270mm

NOTE:

1. VERTICAL CONTROL JOINTS ARE REQUIRED AT MAXIMUM 6m CENTRES.

2. VERTICAL CONTROL JOINTS ARE REQUIRED AT ABOVE AND BELOW ALL DOORS.

3. VERTICAL CONTROL JOINTS ARE REQUIRED ABOVE AND BELOW WINDOW OPENINGS WHEN EXCEEDS 6m.

4. VERTICAL CONTROL JOINTS ARE REQUIRED AT EXTERNAL AND INTERNAL CORNERS.

3.8

MIN. 270 mm

LP-016

16 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 17: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

50mm LITECRETE WALL LAYOUT

SCALE 1:20

50mm LITECRETE LAYOUT

PANEL LENGTH*

50mm LITECRETE LAYOUT

A3ZK

NGD

600

*PANEL LENGTH IS 2000mm.

4.1

LP-017

17 of 27

24.10.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 18: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

CONTROL JOINT

1

2

SINGLE STOREY CONSTRUCTION

SCALE 1:20

50mm LITECRETE GABLE END DETAILS

50mm LITECRETE GABLE END DETAILS

A3ZK

NGB

NOTE:

1. HORIZONTAL CONTROL JOINTS ARE REQUIRED AT EVERY FLOOR JUNCTION.

2. HORIZONTAL CONTROL JOINTS ARE REQUIRED WHEN WALL HEIGHT EXCEEDS 8m.

5.1

LP-018

18 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 19: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

EXTERNAL FRAME

FRAMED WINDOWS AND REVEALS

SEALED TO MANUFACTURER'S DETAILS

2mm GAP SEALED USING

EXTERNAL GRADE SEALANT

COATING SYSTEM AS PER

PROJECT SPECIFICATION

6-10mm NOM.

CONTROL JOINT

6-10mm SOLID PACKER

SECTION 1

SCALE: 1:5

EXTERNAL FRAME

6-10mm NOM.

CONTROL JOINT

6-10mm SOLID PACKER

SECTION 2

SCALE: 1:5

50mm LITECRETE GABLE END DETAILS

250mm OR 2400mm LONG

CONTINUOUS BATTENS

250mm OR 2400mm LONG

CONTINUOUS BATTENS

50mm LITECRETE GABLE END DETAIL

A3ZK

NG

16mm - 40mm CAVITY

16mm - 40mm CAVITY

5.2

14-10 x 100mm MP BUGLE HEAD

TYPE 17 SCREW FOR STEEL

FRAME WITH 20mm AND 40mm

BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10

x150mm HEX HEAD TYPE 17 OR

14-10 x 125mm MP BUGLE HEAD

TYPE 17 SCREW FOR TIMBER

FRAME WITH 40mm BATTEN

14-10 x 100mm MP BUGLE HEAD

TYPE 17 SCREW FOR STEEL

FRAME WITH 20mm AND 40mm

BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10

x150mm HEX HEAD TYPE 17 OR

14-10 x 125mm MP BUGLE HEAD

TYPE 17 SCREW FOR TIMBER

FRAME WITH 40mm BATTEN

B

LP-019

19 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 20: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

50mm LITECRETE WINDOWS

WINDOW SILL - SECTION

SCALE: 1:5

WINDOW HEAD - SECTION

SCALE: 1:5

WINDOW JAMB - SECTION

SCALE: 1:5

5-10mm GAP SEALED USING

EXTERNAL GRADE SEALANT

(REMOVE RUBBER WEATHER STRIP)

CUT PANEL TO HEIGHT

(270mm MIN.)

EXTERNAL FRAME

EXTERNAL FRAME

FRAMED WINDOWS AND REVEALS SEALED

TO MANUFACTURER'S DETAILS

EXTERNAL FRAME

FRAMED WINDOWS AND

REVEALS SEALED TO

MANUFACTURER'S DETAILS

COATING SYSTEM AS PER

PROJECT SPECIFICATION

COATING SYSTEM AS PER

PROJECT SPECIFICATION

2mm GAP SEALED USING

EXTERNAL GRADE SEALANT

250mm OR 2400mm LONG

CONTINUOUS BATTENS

250mm OR 2400mm LONG

CONTINUOUS BATTENS

250mm OR 2400mm LONG

CONTINUOUS BATTENS

50mm LITECRETE

50mm LITECRETE

50mm LITECRETE

50mm LITECRETE WINDOWS

A3ZK

NG

16mm - 40mm CAVITY

16mm - 40mm CAVITY

16mm - 40mm CAVITY

14-10 x 100mm MP BUGLE HEAD TYPE 17

SCREW FOR STEEL FRAME WITH 20mm

AND 40mm BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10 x150mm HEX

HEAD TYPE 17 OR 14-10 x 125mm MP

BUGLE HEAD TYPE 17 SCREW FOR

TIMBER FRAME WITH 40mm BATTEN

14-10 x 100mm MP BUGLE

HEAD TYPE 17 SCREW FOR

STEEL FRAME WITH 20mm

AND 40mm BATTEN AND

TIMBER FRAME WITH 20mm

BATTEN OR 14-10 x150mm

HEX HEAD TYPE 17 OR 14-10 x

125mm MP BUGLE HEAD TYPE

17 SCREW FOR TIMBER

FRAME WITH 40mm BATTEN

14-10 x 100mm MP BUGLE HEAD

TYPE 17 SCREW FOR STEEL FRAME

WITH 20mm AND 40mm BATTEN AND

TIMBER FRAME WITH 20mm BATTEN

OR 14-10 x150mm HEX HEAD TYPE

17 OR 14-10 x 125mm MP BUGLE

HEAD TYPE 17 SCREW FOR TIMBER

FRAME WITH 40mm BATTEN

6.1B

LP-020

20 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 21: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

HEADER DETAIL

SCALE 1:5

2mm GAP

SEALANT

GARAGE HEAD DETAIL

SCALE 1:5

50mm LITECRETE

COATING SYSTEM AS PER

PROJECT SPECIFICATION

CONSTRUCTION ADHESIVE,

ie. MAX BOND OR SIMILAR

EXTERNAL CORNER RENDER BEAD

NAIL FIBRE CEMENT TO TIMBER AND SCREW

AND GLUE TO HEBEL 50mm LITECRETE USING

LIQUID NAILS OR EQUIVALENT

EXTERNAL CORNER

RENDER BEAD

SEALANT

LINTEL OVER

GARAGE

FIBRE CEMENT

SHEET

50mm LITECRETE DOOR AND WINDOW DETAILS

50mm LITECRETE

TIMBER FRAME

FIBRE CEMENT

SHEET

250mm OR 2400mm LONG

CONTINUOUS BATTENS

250mm OR 2400mm

LONG CONTINUOUS

BATTENS

50mm LITECRETE DOOR AND WINDOW DETAILS

A3ZK

NG

16mm - 40mm CAVITY

16mm - 40mm CAVITY

14-10 x 100mm MP BUGLE HEAD TYPE 17

SCREW FOR STEEL FRAME WITH 20mm

AND 40mm BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10 x150mm HEX

HEAD TYPE 17 OR 14-10 x 125mm MP

BUGLE HEAD TYPE 17 SCREW FOR

TIMBER FRAME WITH 40mm BATTEN

14-10 x 100mm MP BUGLE HEAD TYPE 17

SCREW FOR STEEL FRAME WITH 20mm

AND 40mm BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10 x150mm HEX

HEAD TYPE 17 OR 14-10 x 125mm MP

BUGLE HEAD TYPE 17 SCREW FOR

TIMBER FRAME WITH 40mm BATTEN

6.2 B

LP-021

21 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 22: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

GARAGE DOOR - JAMB DETAIL -

OPTION 2

SCALE 1:5

50mm LITECRETE

EXTERNAL CORNER RENDER BEAD

COATING SYSTEM AS PER

PROJECT SPECIFICATION

FIBRE CEMENT SHEET

(OPTIONAL)

DOOR

COATING SYSTEM AS PER

PROJECT SPECIFICATION

EXTERNAL STUD FRAME

JAMB

TIMBER STORM MOULD OR QUAD

50mm LITECRETE GARAGE DOOR DETAILS

GARAGE DOOR - JAMB DETAIL -

OPTION 1

SCALE 1:5

DOOR

INSTALL WALL WRAP AROUND

FIRST STUD IN DIRECT CONTACT

WITH THE FIBRE CEMENT

WALL WRAP OVER STUD

FRAME (OPTIONAL)

50mm LITECRETE

EXTERNAL STUD FRAME

50mm LITECRETE GARAGE DOOR DETAILS

A3ZK

NG

16mm - 40mm CAVITY

16mm - 40mm CAVITY

14-10 x 100mm MP BUGLE HEAD TYPE 17

SCREW FOR STEEL FRAME WITH 20mm

AND 40mm BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10 x150mm HEX

HEAD TYPE 17 OR 14-10 x 125mm MP

BUGLE HEAD TYPE 17 SCREW FOR

TIMBER FRAME WITH 40mm BATTEN

14-10 x 100mm MP BUGLE HEAD TYPE 17

SCREW FOR STEEL FRAME WITH 20mm

AND 40mm BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10 x150mm HEX

HEAD TYPE 17 OR 14-10 x 125mm MP

BUGLE HEAD TYPE 17 SCREW FOR

TIMBER FRAME WITH 40mm BATTEN

6.3B

LP-022

22 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 23: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

PAINTABLE EXTERNAL

GRADE SEALANT OVER

BACKINF ROD

WALL WRAP (OPTIONAL)

COATING SYSTEM AS PER

PROJECT SPECIFICATION

EXTERNAL FRAME

RO

OF

A

ND

C

EILIN

G S

TR

UC

TU

RE

QUAD OR SIMILAR

WALL WRAP (OPTIONAL)

NOMINAL 30mm

TYPICAL ROOF EAVES DETAILS -

PANELS AT EAVE HEIGHT

SCALE 1:5

50mm LITECRETE WALL EAVE DETAILS

RO

OF

A

ND

C

EILIN

G S

TR

UC

TU

RE

TYPICAL ROOF EAVES DETAILS -

PANELS EXTENDED PAST EAVE

SCALE 1:5

PANEL CUT TO HEIGHT 270mm MIN.

20-40 20-40

AAC ADHESIVE JOINT

COATING SYSTEM AS PER

PROJECT SPECIFICATION

EXTERNAL FRAME

PANEL CUT TO HEIGHT 270mm MIN.

AAC ADHESIVE JOINT

50mm LITECRETE

50mm LITECRETE

50mm LITECRETE WALL EAVE DETAIL

A3ZK

NG

16mm - 40mm CAVITY 16mm - 40mm CAVITY

14-10 x 100mm MP BUGLE HEAD

TYPE 17 SCREW FOR STEEL FRAME

WITH 20mm AND 40mm BATTEN AND

TIMBER FRAME WITH 20mm BATTEN

OR 14-10 x150mm HEX HEAD TYPE

17 OR 14-10 x 125mm MP BUGLE

HEAD TYPE 17 SCREW FOR TIMBER

FRAME WITH 40mm BATTEN

14-10 x 100mm MP BUGLE HEAD

TYPE 17 SCREW FOR STEEL FRAME

WITH 20mm AND 40mm BATTEN AND

TIMBER FRAME WITH 20mm BATTEN

OR 14-10 x150mm HEX HEAD TYPE

17 OR 14-10 x 125mm MP BUGLE

HEAD TYPE 17 SCREW FOR TIMBER

FRAME WITH 40mm BATTEN

7.1 B

LP-023

23 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 24: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

50mm LITECRETE TWO STOREY ROOF JUNCTION DETAILS

50mm LITECRETE TWO STOREY ROOF JUNCTION DETAILS

A3ZK

NG

RO

OF

A

ND

C

EIL

IN

G S

TR

UC

TU

RE

ROOF FLASHING

SYSTEM BY OTHERS

POLYURETHANE SEALANT

EXTERNAL FRAME

ROOF AND CEILING

STRUCTURE

WALL WRAP

(OPTIONAL)

250mm OR 2400mm LONG

CONTINUOUS BATTENS

COATING SYSTEM AS PER

PROJECT SPECIFICATION

16mm - 40mm CAVITY

14-10 x 100mm MP BUGLE HEAD TYPE 17

SCREW FOR STEEL FRAME WITH 20mm

AND 40mm BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10 x150mm HEX

HEAD TYPE 17 OR 14-10 x 125mm MP

BUGLE HEAD TYPE 17 SCREW FOR

TIMBER FRAME WITH 40mm BATTEN

ROOF AND CEILING

STRUCTURE

ROOF FLASHING

SYSTEM BY OTHERS

RO

OF

A

ND

C

EIL

IN

G S

TR

UC

TU

RE

EXTERNAL FRAME

WALL WRAP

(OPTIONAL)

250mm OR 2400mm

LONG CONTINUOUS

BATTENS

COATING SYSTEM AS PER

PROJECT SPECIFICATION

16mm - 40mm CAVITY

14-10 x 100mm MP BUGLE HEAD TYPE 17

SCREW FOR STEEL FRAME WITH 20mm

AND 40mm BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10 x150mm HEX

HEAD TYPE 17 OR 14-10 x 125mm MP

BUGLE HEAD TYPE 17 SCREW FOR

TIMBER FRAME WITH 40mm BATTEN

8.1

POLYURETHANE

SEALANT

10-15mm

3-6mm

B

LP-024

24 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 25: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

50mm LITECRETE

WALL FRAME

FLASHING BY OTHERS

50mm LITECRETE

WALL FRAME

FLASHING BY OTHERS

10mm MIN.

DEFLECTION GAP

10mm MIN. DEFLECTION GAP

30mm NOMINAL OFFSET

FROM TOP HAT

DPC

ROOF TO WALL JUNCTION DETAIL - OPTION 1

SCALE 1:5

ROOF TO WALL JUNCTION DETAIL - OPTION 2

SCALE 1:5

50mm LITECRETE WALL TO ROOF JUNCTIONS

POLYURETHANE

SEALANT

10-15mm

3-6mm

50mm LITECRETE WALL TO ROOF JUNCTIONS

A3ZK

NG

16mm - 40mm CAVITY

16mm - 40mm CAVITY

14-10 x 100mm MP BUGLE HEAD TYPE 17

SCREW FOR STEEL FRAME WITH 20mm

AND 40mm BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10 x150mm HEX

HEAD TYPE 17 OR 14-10 x 125mm MP

BUGLE HEAD TYPE 17 SCREW FOR

TIMBER FRAME WITH 40mm BATTEN

14-10 x 100mm MP BUGLE HEAD

TYPE 17 SCREW FOR STEEL

FRAME WITH 20mm AND 40mm

BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10

x150mm HEX HEAD TYPE 17 OR

14-10 x 125mm MP BUGLE HEAD

TYPE 17 SCREW FOR TIMBER

FRAME WITH 40mm BATTEN

8.2 B

LP-025

25 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 26: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

FALL

FIBRE CEMENT SHEET

TIMBER SUPPORT

STRUCTURAL WALL FRAMING

CLIP AND SCREW TO

SUIT CAPPING

CLEARANCE TO ALLOW FOR

TIMBER FRAME SHRINKAGE

CA

PP

IN

G O

VE

RLA

P

100m

m M

IN

.

WALL WRAP TO BE INSTALLED TO

50mm LITECRETE SIDE OF STUD

FRAME (OPTIONAL) TO

MANUFACTURERS DETAILS

50mm LITECRETE

30mm

MIN

PARAPET CAPPING

SCALE 1:5

NOTE:

PARAPET CAPPING SHALL BE DESIGNED AND FASTENED IN

ACCORDANCE WITH SAA - HB39 1997 - INSTALLATION CODE FOR METAL

ROOFING AND WALL CLADDING. STOP ENDS SHALL BE INCORPORATED

TO ALL FLASHINGS.

50mm LITECRETE PARAPET CAPPING

WALL WRAP TO BE INSTALLED BETWEEN

TIMBER FRAME AND FIBRE CEMENT SHEET TO

MANUFACTURERS DETAILS

250mm OR 2400mm LONG

CONTINUOUS BATTENS

50mm LITECRETE PARAPET CAPPING

A3ZK

NG

16mm - 40mm CAVITY

14-10 x 100mm MP BUGLE HEAD TYPE 17

SCREW FOR STEEL FRAME WITH 20mm

AND 40mm BATTEN AND TIMBER FRAME

WITH 20mm BATTEN OR 14-10 x150mm HEX

HEAD TYPE 17 OR 14-10 x 125mm MP

BUGLE HEAD TYPE 17 SCREW FOR

TIMBER FRAME WITH 40mm BATTEN

9.1 B

LP-026

26 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE
Page 27: 50mm LITECRETE CONNECTION DETAILS · batten and timber frame with 20mm batten or 14-10 ... concrete slab this slab edge detail does not comply with the termite visible inspection

50mm

50mm

600mm MAX.

COLUMN DETAIL (GLUED AND SCREWED)

SCALE 1:5

50mm LITECRETE

(HORIZONTALLY INSTALLED)

SCREW FIXED AT 600mm CTR

USING 14 - 10x100mm BUGLE

HEAD TYPE 17 SCREWS

50mm LITECRETE COLUMN DETAIL

AAC ADHESIVE JOINT

650mm MAX.

50mm LITECRETE COLUMN DETAIL

A3ZK

NGA

CONTINUOUS TIMBER OR

STEEL SUPPORT

SCREW FIXED AT 600mm CTR

USING 14 - 10x100mm BUGLE

HEAD TYPE 17 SCREWS

SCREW FIX 50mm LITECRETE TO

POST AT 600mm CTR USING 14 -

10x100mm BUGLE HEAD TYPE 17

SCREWS

SCREW FIX BATTEN TO POST AT

600mm CTR USING 14 - 10x100mm

BUGLE HEAD TYPE 17 SCREWS

CONTINUOUS HORIZONTAL

BATTENS AT 600mm CTR

10.1

LP-027

27 of 27

24.09.18

AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING REFERENCE