50091593-Manuale-BISAR

47
BISAR 3.0 User Manual This document is CONFIDENTIAL. Neither the whole nor any part of this document may be disclosed to any third party without the prior written consent of Shell International Oil Products B.V., The Hague. The copyright of this document is vested in Shell International Oil Products B.V., The Hague. All rights reserved. Neither the whole nor any part of this document may be reproduced, stored in any retrieval system or transmitted in any form or by any means (electronic, mechanical, reprographic, recording or otherwise) without the prior written consent of the copyright owner. Bitumen Business Group May 1998

Transcript of 50091593-Manuale-BISAR

Page 1: 50091593-Manuale-BISAR

BISAR 3.0

User Manual

This document is CONFIDENTIAL. Neither the whole nor any part of this document may bedisclosed to any third party without the prior written consent of Shell International Oil Products B.V.,The Hague.

The copyright of this document is vested in Shell International Oil Products B.V., The Hague. Allrights reserved. Neither the whole nor any part of this document may be reproduced, stored in anyretrieval system or transmitted in any form or by any means (electronic, mechanical, reprographic,recording or otherwise) without the prior written consent of the copyright owner.

Bitumen Business GroupMay 1998

Page 2: 50091593-Manuale-BISAR

Contents

1. Introduction 3

2. Main Principles of the BISAR Program 4

3. System Requirements 6

4. Installing BISAR 3.0 7

4.1 Installation from CD-ROM 7

4.2 Installation from diskettes 8

5. Use of BISAR 3.0 11

6. Starting BISAR 3.0 12

7. File and Database Management 14

Editing existing Projects input data 14

Deleting Input Data 16

Accessing and Deleting Previous Calculations 17

Database Maintenance 17

Saving Project Input and Calculations 18

8. Working with Tables 19

9. Printing in BISAR 3.0 20

Print Preview 21

Printing to the printer 21

10.Performing BISAR Calculations 22

10.1 Outline of Input and Output 22

10.2 Input Arrangements for the Standard Dual Wheel 30

10.3 Calculations with Shear Spring Compliance 33

11.BISAR 3.0 Reports 35

11.1 The Block Report 35

11.2 Detailed Report 38

12.Error Messages 41

Appendix 1 42

BISAR Calculations with Slip between Layers 42

A1.1 Theoretical Background 42

Appendix 2 44

The radial direction within fixed and local co-ordinate systems 44

Appendix 3 46

Overview of Units and Prefixes 46

References 47

Page 2

Page 3: 50091593-Manuale-BISAR

1. Introduction

The Windows computer program BISAR 3.0 replaces the DOS version BISAR-PC 2.0. Theprogram is suitable for Windows 3.1, Windows 95 and Windows NT.

In the early 1970s, Shell Research developed the BISAR mainframe computer program1, whichwas used in drawing the design charts of the Shell Pavement Design Manual issued in 1978. Anabbreviated version of the BISAR program for use on a personal computer2 was issued in 1987as BISAR-PC (Release R 1.0). A PC version comprising all extensive mainframe options wasnot feasible, because of the lengthy calculations at that time, The PC version was issued tofacilitate the use of the design charts and to avoid laborious interpolations. To avoid theselimitations, the DOS program BISAR-PC 2.0, issued in 1995, offered all the possibilities of theformer mainframe program.

With the release of BISAR 3.0 the full possibilities of the original mainframe BISAR computerprogram are now available for use in the Windows environment. In addition to the calculation ofstresses and strains BISAR 3.0 is capable of calculating deflections and is able to deal withhorizontal forces and slip between the pavement layers. This offers the opportunity to calculatecomprehensive stress and strain profiles throughout the structure for a variety of loadingpatterns, including air-crafts. In this way, BISAR 3.0 package is a valuable calculation tool,which can be used for refining the SPDM 3.0* designs, to carry out more complicated designs(e.g. for cement-bounded base layers or airport designs) and as a stand-alone program fortheoretical calculations on elastic multi-layer systems.

To facilitate SPDM related calculations the present BISAR 3.0 version contains options toaccess with ease the Standard Dual Wheel Configuration and to automatically select importantpositions in the layer structure under consideration.

The BISAR 3.0 package provides two types of output. The so-called ‘Detailed Report’ containsthe same information as the original BISAR mainframe program. The ‘Block Report’ provides anoverview of the main results, which in general meets the needs for less complex studies.

BISAR 3.0 comprises advanced report layout, improved file and database management. Itfurther includes automatic calculation of the layer number and facilitates selection of positionsat a layer interface.

Page 3

* SPDM 3.0 is the Windows version of the computerised Shell Pavement Design Method.

Page 4: 50091593-Manuale-BISAR

2. Main Principles of the BISAR Program

With the BISAR program, stresses, strains and displacements can be calculated in an elasticmulti-layer system which is defined by the following configuration and material behaviour:1. The system consists of horizontal layers of uniform thickness resting on a semi-infinite base

or half space.2. The layers extend infinitely in horizontal directions.3. The material of each layer is homogeneous and isotropic.4. The materials are elastic and have a linear stress-strain relationship.

The system is loaded on top of the structure by one or more circular loads, with a uniform stressdistribution over the loaded area. The program offers the possibility to calculate the effect ofvertical and horizontal stresses (shear forces at the surface**) and includes an option to accountfor the effect of (partial) slip between the layers, via a shear spring compliance at the interface.

BISAR calculations require the following input:- the number of layers- the Young’s moduli of the layers- the Poison’s ratios of the layers- the thickness of the layers (except for the semi-infinite base layer)- the interface shear spring compliance at each interface- the number of loads- the co-ordinates of the position of the centre of the loads- one of the following combinations to indicate the vertical normal component of the load

- stress and load- load and radius- stress and radius

- (optional) the horizontal tangential component of the load and the direction of this shear load- the co-ordinates of the positions for which output is required.

The centre of the loads and the positions at which stresses, strains and displacements have tobe calculated are given as co-ordinates in a fixed Cartesian co-ordinate system. The actualcalculations to determine the response of a particular load in terms of stresses, strains anddisplacements are, however, carried out within a local cylindrical co-ordinate system having thecentre of the load as origin. The effect of the simultaneous action of various loads is the sum ofthe effects due to the action of each separate load. This summation is carried out aftertransformation of the results with respect to the underlying Cartesian co-ordinate system.

The program calculates the eigen values and eigen vectors of the stress and strain tensors, theprincipal stresses and strains and the corresponding principal directions. The maximum andminimum principal values represent the maximum and minimum normal stresses and strains.The principal directions denote the normals of the planes through the point under considerationthat are free of shear stresses and strains. The maximum shear stresses and strains, acting inplanes bisecting the principal directions are equal to half the difference between these principalvalues. Since these maximum shear stresses can also be considered in failure studies, they arecalculated too, together with the midpoints of the Mohr’s stress circles and the total energydensity and strain energy density of distortion at the considered position.

BISAR may account for slip between layers. This is incorporated through a shear springcompliance. The standard calculations within BISAR-PC are done with full friction between allthe layers. The method to make calculations assuming full or partial slip between all or some ofthe layers is explained in Appendix 1.

Page 4

** In calculations dealing with shear forces acting at the loaded surface, no response should be asked for positions atthe surface. BISAR does not properly account for that boundary condition and calculated results may be erroneous.In such cases it is recommended to select a position just below the surface of the structure.

Page 5: 50091593-Manuale-BISAR

The detailed output comprises the following information for each selected position in thestructure under consideration:• for each load separately (all expressed in terms of the cylindrical co-ordinate system for the

loading):- the components of the stress tensor (normal and shear)- the components of the strain tensor (normal and shear)- the components of the displacement vector

• for the combined action of all loads (all expressed in terms of the fixed Cartesian co-ordinatesystem:- the components of the stress tensor (normal and shear)- the components of the strain tensor (normal and shear)- the components of the displacement vector- the principal values and directions of the stress tensor- the principal values and directions of the strain tensor- the maximum shear stresses and strains- the midpoint of the Mohr’s stress circles- the strain energy of distortion- the total strain energy.

A full description of the fundamentals behind the BISAR program is given in the user guide ofthe first program (External Report AMSR.0006.73). Essential parts of this document remainavailable to interested parties for reference to the theoretical basis of the elastic multi-layermodel.

Page 5

Page 6: 50091593-Manuale-BISAR

3. System Requirements

The minimum requirements for the computer system to run BISAR 3.0 are as follows:

Part Description

Computer IBM (or compatible) PC with a 486DX2-50 MHz or higher processor

Operating system Windows 3.1, Windows 95, Windows NT 3.51, Windows NT 4.0

Memory 4 MB of memory (8 MB recommended for Windows 95, 16 MB recommended for Windows NT)

Disk-drive The program is supplied on CD-ROM. On request it is available on two high density diskettes of 1.44 MB

Hard disk 6 MB of available disk space

Screen VGA display or better

Mouse Microsoft Mouse or compatible pointing device

Printer Any Windows compatible printer

Page 6

Page 7: 50091593-Manuale-BISAR

4. Installing BISAR 3.0

4.1 Installation from CD-ROM

In Windows 3.x

• Start Windows (or close all running programs if Windows is already started)

• Place the CD-ROM in your CD-ROM drive

• Select File/Run from the Program Manager

• Type: D:\BISAR3\SETUP (where D: is the drive letter assigned to your CD-ROM drive)

• Press the [Enter] key

• Follow the instructions in the section “Installation Screens (CD-ROM)” below

In Windows 95/NT

• Start Windows 95/NT (or close all running programs if Windows 95/NT is already started)

• Place the CD-ROM in your CD-ROM drive

• Select Run from the Start menu

• Type: D:\BISAR3\SETUP (where D: is the drive letter assigned to your CD-ROM drive)

• Press the [Enter] key

• Follow the instructions in the section “Installation Screens (CD-ROM)” below

Installation Screens (CD-ROM)Once the installation of BISAR 3.0 has started, the following screen will be displayed:

It is recommended that BISAR 3.0 is installed in a directory called BISAR3, however, a differentdirectory may be specified. Pressing the OK button starts the process of installing theBISAR 3.0 files into the specified directory.

As files are installed, a progress meter is updated as shown below:

Page 7

Page 8: 50091593-Manuale-BISAR

Installation is complete when the following window is displayed:

4.2 Installation from diskettes

In Windows 3.x

• Start Windows (or close all running programs if Windows is already started)

• Place the disk labelled “BISAR 3.0 Disk 1 of 2” in Drive A:\

• Select File/Run from the Program Manager

• Type: A:\SETUP

• Press the [Enter] key

• Follow the instructions in the section “Installation Screens” below

In Windows 95/NT

• Start Windows 95/NT (or close all running programs if Windows 95/NT is already started)

• Place the disk labelled “BISAR 3.0 Disk 1 of 2” in Drive A:

• Select Run from the Start menu

• Type: A:\SETUP

• Press the [Enter] key

• Follow the instructions in the section “Installation Screens” below

Page 8

Page 9: 50091593-Manuale-BISAR

Installation Screens (diskettes)Once the installation of BISAR 3.0 has started, the following screen will be displayed:

It is recommended that BISAR 3.0 is installed in a directory called BISAR3, however, a differentdirectory may be specified. Pressing the OK button starts the process of installing theBISAR 3.0 files into the specified directory.

As files are installed, a progress meter is updated as shown below:

When the following screen is displayed, remove DISK 1 and replace it with DISK 2 beforepressing the OK button.

Page 9

Page 10: 50091593-Manuale-BISAR

Installation is complete when the following window is displayed:

Installation TroubleshootingIf installation appears to be extremely slow, or if problems are encountered as installationprogresses, files may be manually copied to your hard disk and installed from there. To do this,follow the instructions below.

• Using File Manager (in Windows 3.x) or Windows Explorer (in Windows 95) to create atemporary directory on your hard disk.

• Copy all of the files from both BISAR 3.0 installation disks to this temporary directory.

• Run the BISAR 3.0 SETUP program from this temporary directory.

Once installation has completed, the temporary directory may be removed.

Network InstallationAlthough BISAR 3.0 may be installed on and run from a network, it is not recommended sincethe internal database is not designed for multi-user access.

Page 10

Page 11: 50091593-Manuale-BISAR

5. Use of BISAR 3.0

Each BISAR 3.0 project (run) can deal with ten separate sets of input. A single set of input isdefined as a system. Within each system the program can deal with ten layers and ten circularloads. The use of more systems in one BISAR project facilitates studies into the effect of certainparameters e.g. variation of modulus or thickness by extending the number of positions.

The way to indicate the positions (the co-ordinates in the layer structure where calculationresults are asked) has been improved. It is no longer necessary to provide the layer number,which is now calculated automatically from the Z-co-ordinate. For positions at the interfacebetween two layers, the program offers the opportunity to select a specific layer or to choose forcalculating the results at the same position in both layers. Stresses, strains and displacementscan usually be calculated at ten positions per system. This number is extended when interfacepositions are selected for both layers.

The original BISAR mainframe program contained an option to select between the a ‘rough’ andthe ‘smooth’ calculation method. The ‘rough’ method was introduced to speed-up mainframecomputer calculations. With the present fast PC’s, the ‘rough’ calculation method has becomeobsolete and the ‘smooth’ method is standard for all the calculations within BISAR 3.0.

To facilitate SPDM related calculations the present BISAR 3.0 version contains options to easyaccess the Standard Dual Wheel Configuration and to automatically select important positionsin the layer structure under consideration.

The output of BISAR 3.0 comprise two types of reports. The ‘Detailed Report’ contains thesame information as the output of the original mainframe program, but in an improved lay-out. Ashortened report, the so-called ‘Block Report’ comprises normal stresses, normal strains anduniaxial displacements at each selected position in the structure. The results in the ‘DetailedReport’ and the ‘Block Report’ can be copied to the Windows clipboard for importing the resultsof the calculation into commercial Windows programs for preparing graphics etc.

The BISAR 3.0 package is based on SI-Units. The units with their prefixes are displayed in thecolumns of the input screens. In contrast to previous versions (BISAR Mainframe and BISAR-PC 2.0) the ‘Detailed Report’ also includes display of units, be it without the prefixes used ininput windows and Block Report. The actual units and their prefixes for input and output inBISAR 3.0 are listed in Appendix III.

BISAR 3.0 comprises modules for input, calculations and reporting / displaying results. Theprogram does not contain a module for interpretation of results and comparisons with specificmaterial properties (e.g. fatigue relations) or specific design criteria. Such interpretation ispossible with the SPDM 3.0 program, the computerised Shell Pavement Design Manual,although SPDM is more limited in the number of layers and positions to be considered.

To analyse stress and strain profiles for user defined structures and loading patterns it isrecommended to use the BISAR 3.0 facility to copy and paste output to other Windowsprograms. Copy and paste to a graphics program can be used to find e.g. the maximum asphaltstresses and strains (not necessarily at the bottom of the asphalt). The facility is alsorecommended for importing data to programs with user’s own specific design criteria.

Page 11

Page 12: 50091593-Manuale-BISAR

6. Starting BISAR 3.0

The program is started by double-clicking the BISAR icon: and the main windowappears with the following pull-down menus• Project• Help

The options for the Project pull-down menu are:• New• Open• Previous Calculations• Delete• Compact Database• Repair Database• Exit

New and Open are used for the actual calculations. New is used to set-up a new project whileOpen is used to edit input of already existing projects. These options are explained insection 10 of this manual.

Previous Calculations is used to access the reports (output) of previous projects. Delete isused to for deleting input with the following options:• Project Input• Loads• Layers• Positions

Details for Previous Calculations and Delete are given in section 7.

Compact database and Repair Database are used to maintain the internal BISAR databases(see section 7)

Exit closes the application.

When opening a New or existing project (Open) following additional pull-down menus becomeavailable:• Edit• Copy From• Results• Window• Help

Edit is used to undo all changes within project input data. Copy From is used to copy inputdata from system to system. Results is used to start the calculations.

The Window pull-down menu offers the possibility to use the well-known general Windowsoptions:• Cascade• Windows

for arranging and selecting the various windows.

The Help menu offers the general Windows Help options

• Contents• Search For Help On• About BISAR 3.0

Page 12

Page 13: 50091593-Manuale-BISAR

Help is also always available when pressing F1, except within Block Report and DetailedReport. For details using Help, refer to your Windows Manual on Help.

Page 13

Page 14: 50091593-Manuale-BISAR

7. File and Database Management

Input and output (reports) are stored in an internal BISAR 3.0 database. In this way, the user isnot troubled with the management of separate input and output files on his computer via theFile Manager or the Windows Explorer. This set-up implies that all file management has to bedone within the BISAR program. It allows the use of narrative descriptions (long names) for thevarious database parts.

The structure of the internal database is as follows:

Project Contains input data (Loads, Layers and Positions) for a certainProject (maximum 10 Systems).

Previous Calculations Contains input and output for a certain Project (Block Report,Detailed Report, Block Table, Detailed Table).

Loads Contains user defined Load configurations, which can be savedand retrieved when preparing input for a certain Project.

Layers Contains user defined Layer / structure configurations, which canbe saved and retrieved when preparing input for a certain Project.

Positions Contains user defined Positions, which can be saved and retrievedwhen preparing input for a certain Project.

Editing existing Projects input dataTo edit existing input data in order to define a new Project is done via Project, Open from themain BISAR window:

Page 14

Page 15: 50091593-Manuale-BISAR

resulting in display of a window like

to select a certain project for editing e.g.

which allows all options for Systems, Loads, Layers and Positions as explained for starting aNew Project (see section 10.1)

Page 15

Page 16: 50091593-Manuale-BISAR

Deleting Input DataThe option to delete specific Project input, Load configurations, Layer structures and series ofpositions can be approached via Delete.

Note that this option is only available when all projects are closed.

After selecting Project Input, Loads, Layers or Positions a following window (or similar) isdisplayed to delete a certain item

Page 16

Page 17: 50091593-Manuale-BISAR

Accessing and Deleting Previous CalculationsThe content of Previous Calculations can be assessed via Project, Previous Calculationsresulting in display of a window like

Via this way it is possible to select project output • for browsing and printing by choosing Block Report or Detailed Report (see Section 9)• for copy to clipboard and pasting to any Windows application by clicking Block Table or

Detailed Table• to Delete specific output.

Database Maintenance Under certain circumstances (e.g. loss of power in the middle of a calculation) it is possible thatthe BISAR 3.0 database is corrupted. If this occurs then the following message will be displayedwhen attempting to open or save projects:

Selecting the Repair Database option will remove any corruption of data which might haveoccurred and BISAR 3.0 operation will continue normally.

When projects and results are deleted from the BISAR 3.0 database, the space that they onceoccupied is not automatically reclaimed. The Compact Database option manually reclaims thisspace. Please note that if used infrequently, database compaction can take one or two minutesto complete.

Page 17

Page 18: 50091593-Manuale-BISAR

Saving Project Input and CalculationsProject Input can be saved at any time through use of the Project menu options:

either via Save or via Save as.

Page 18

Page 19: 50091593-Manuale-BISAR

8. Working with Tables

Whenever the Block Table or Detailed Table button is selected from the Calculated Datawindow is selected, a table of calculated results is displayed. The following example shows aBlock Table:

The Block (or Detailed) Table provides a convenient way to view a large number of results (upto 2000). Horizontal and vertical scroll bars will appear, if necessary, to allow navigation whenmore results have been calculated than can be displayed in the Table window.

The Table is initially displayed with all results selected (highlighted). Pressing the Copy toClipboard button will copy the selected results to the clipboard so that they may be pasted intoanother application. For example, copying the results and pasting them into a spreadsheetapplication would allow the graphing of results etc.

If too many results are selected for copying, the following message will be displayed:

If the above error message appears, it is still possible to copy all results to another applicationby copying the results in a number of smaller selections. To copy a smaller selection, use themouse to point to the first required cell and drag to the last required cell (the cells will appearhighlighted). Now use the Copy to Clipboard option to copy the selected cells. It is possible toselect whole columns of results by clicking on the heading for the desired column.

The Block Table and Detailed Table options are also available from Previous Calculations.

Page 19

Page 20: 50091593-Manuale-BISAR

9. Printing in BISAR 3.0

Whenever a report is created in BISAR 3.0 (by pressing the Block Report or Detailed Reportbutton) a preview window similar to the following is displayed:

The arrow buttons at the top of the preview window enable you to move backwards andforwards in your report. The action of those buttons is as follows:

Moves you to the first page of the report

Moves you to the previous page

Moves you to the next page

Moves you to the last page of the report

Cancels page formatting. For long reports, page formatting may take a fewmoments. If you want to stop the page formatting, press this button.

Previews the page to be printed

Sends your report to the printer

NOTE:You can also use the keyboard to move around in the print window. [Ctrl]+[Home] movesyou to the first page, [Pg Up] moves you to the previous page, [Pg Dn] moves you to the nextpage, [Ctrl]+[End] moves you to the last page, and [Esc] closes the print window.

NOTE:You can use the scroll bars to move around individual pages of the report.

Page 20

Page 21: 50091593-Manuale-BISAR

Print PreviewThe magnifying glass button is the print preview button. This button lets you see each page inits entirety, as it will print. When you Click this button, the program displays the page that’scurrently in the preview window, reduced in size so the entire page fits in the window at onetime.

Printing to the printerTo send the displayed report to the printer, click the printer button. A screen similar to thefollowing will be displayed. Note that BISAR 3.0 will print the report on your default printer. Toselect a different printer in Windows 3.x use the printers option in the control panel. To select adifferent printer in Windows 95, use the printers option in My Computer.

The print range option allows you to print all or just part of your report. Select ALL to print theentire report or specify a page range for a partial report.

The default number of copies printed is 1, however this may be changed by specifying adifferent number in the copies box.

The Collate Copies option determines how multiple copies of a report are printed. To printmultiple copies of a multiple page report in the order 1,1,1,2,2,2,3,3,3, etc. leave this optionempty. To print multiple copies of a multiple page report in the order 1,2,3...,1,2,3…, etc. thenselect this option. Note that certain printers do not respond to this collating option and willalways print a report in the order 1,2,3…,1,2,3…, etc.

Page 21

Page 22: 50091593-Manuale-BISAR

10. Performing BISAR Calculations

10.1 Outline of Input and OutputWhen starting a new project (run) via Project and New the following input window appears:

A new project is ’untitled’ and a project name can be given after completing the input andstarting the calculations. The default number of Systems (maximum 10) is set at 1. The inputpanels for a certain system are made active via Tabs. The System Description box offers thepossibility to give narrative details. Per system the input panels for Loads, Layers andPositions can be made active.

The load characteristics can be given in three modes:• Stress and Load • Load and Radius (default)• Stress and Radius.

The example below shows typical input data for a Super Single Wheel in the Load and Radiusmode (next page).

Page 22

Page 23: 50091593-Manuale-BISAR

It is possible to Save and Retrieve user defined load configurations in the internal database* .By pressing Save in the Loads panel a following window appears

Page 23

* By clicking the Use Standard Dual Wheel checkbox, it is possible to directly include the standard dual wheelcharacteristics as used within the Shell Pavement Design Method (see section 10.2).

Page 24: 50091593-Manuale-BISAR

Corresponding structure data have to be given in the Layer panel e.g.

The number of layers can be varied between 1 and 10. The checkbox Full Friction BetweenLayers is active as default.

BISAR offers the opportunity to study the effect of full andpartial slip between certain layers in the structure via the socalled Shear Spring Compliance parameter.The use of thisoption is explained in section 10.3 and Appendix 1.

The next step is to provide the co-ordinates of Positions in the structure where output is desired.It is not possible to select positions without defining the structure first.

The Position panel below shows (by way of example) the co-ordinates below the centre of theload at the top of the surface, in the middle of the top layer, the interface between layer 1 and 2,a position in layer 2 and the interface between layer 2 and 3. With this new version of BISAR itis no longer required to input the layer number. This number is now automatically calculated anddisplayed when typing the Z - co-ordinate of the position.

A proper choice of the layer number is very important because atthe interface discontinuities may occur. Discontinuities may forinstance occur in

• vertical strains and horizontal stresses when the modulus onboth side of the interface is different

• horizontal strains when slip between the layers occurs.

Page 24

Page 25: 50091593-Manuale-BISAR

When a Z- co-ordinate is positioned at an interface the layer number is indicated in the format1/2. The panel offers the possibility to select the desired layer number or to choose both byclicking the Select Layer button

e.g. as follows

Page 25

Page 26: 50091593-Manuale-BISAR

By clicking the Number of Systems indicator in top of the input panel, the number of systemsfor a certain project can be extended up to 10. In that case more system indicators becomeavailable e.g. system 2, starting with empty data fields:

Page 26

Page 27: 50091593-Manuale-BISAR

Via Copy From and (in this case) selecting System 1, the already provided content ofSystem 1 is copied to System 2, and can be adjusted where required. In many cases, the userwould define new positions in order to obtain extended stress and strain profiles for a given loadconfiguration and a certain layer structure.

Calculations are started by selecting Results and Calculate or by pressing F5

and the following message is displayed:

Here the user has the opportunity to save the input data and to give a description (name) to theproject input by pressing Yes:

Page 27

Page 28: 50091593-Manuale-BISAR

After pressing OK, the calculations are performed and the following window is displayed:

The output of the calculations can be accessed as (see also sections 8 and 9)

• Block Report• Detailed Report• Block Table• Detailed Table

The Detailed output contains the same extended information as produced by the originalBISAR mainframe computer program. The Block output compiles the main results. The Reportfunction prepares for browsing and printing.

When using the Table option a following window is displayed, in which the data is selected andready for Copy to Clipboard. This option gives the opportunity to copy and paste data to anyother Windows application.

Page 28

Page 29: 50091593-Manuale-BISAR

Closing the Table and the Calculated Data window results in the display of

After confirmation via Yes the calculation results are saved under the same name as the projectinput and may be reassessed through use of the Previous Calculations options in the Projectmenu.

Undo All Changes on the Edit menu will cancel all changes since the last time Project Inputwas saved.

Details on file management items as Saving are described in section 7.

Page 29

Page 30: 50091593-Manuale-BISAR

10.2 Input Arrangements for the Standard Dual WheelBISAR 3.0 includes the possibility to perform extensive calculations the Standard Dual WheelConfiguration (80kN standard axle) as used in the Shell Pavement Design Manual and theSPDM 3.0 computer program.

Within the SPDM package the use of BISAR is limited with respect to the number of layers andthe number of positions. Use of the new BISAR Standard Dual Wheel Arrangements offers thepossibility to analyse stress and strain profiles in much more detail and to study more complexstructures (up to ten layers, including e.g. high modulus cement-bound base-layers).

The Standard Dual Wheel load configuration can be directly chosen by clicking the UseStandard Dual Wheel checkbox

and confirming

Page 30

Page 31: 50091593-Manuale-BISAR

After defining a certain layer structure e.g.

the program gives the possibility to directly select relevant positions for the combination ofStandard Dual Wheel and the given layer structure by clicking Select Positions for StandardDual Wheel in the Positions panel of the System, resulting in (after confirmation)

Page 31

Page 32: 50091593-Manuale-BISAR

This implies that the following positions are automatically selected:

• all positions underneath the load position between the wheels and load position under awheel for– the top of the undermost (infinite thick) layer– the bottom of all the other layers.

Because all these positions are by definition at an interface, it is possible to select both interfacepositions and/or the same position in the layer above the interface.

This facility accommodates structures up to five layers. For structures withmore layers, the automatic section of positions will apply to the top of theundermost layer and the bottom of the four top layers. It is of course possibleto extend the number of positions when the load configuration and the layerstructure is copied to a new system within the project.

Page 32

Page 33: 50091593-Manuale-BISAR

10.3 Calculations with Shear Spring ComplianceThe BISAR calculations outlined in Section 10.1 assume full friction (perfect adhesion) betweenall layers of the structure under consideration. One of the possibilities of BISAR is the capabilityto account for (full or partial) slip. This type of calculation is made with aid of the shear springcompliance. Detailed information on the theoretical background and the use of the shear springcompliance parameter is given in Appendix 1.

Shear spring compliance values are provided in the input panel for Layers:

In this case a reduced spring compliance value of 15 m (for the interface of layers 2/3 and 3/4 ischosen as 100 times the radius of the load. As explained in Appendix 1 this value approximatesfull slip. The corresponding load itself is defined in the Loads input screen:

Page 33

Page 34: 50091593-Manuale-BISAR

The user can choose between input of the standard and reduced shear spring compliance inthe Layers input screen. There is an automatic link between the two compliance modes. Byclicking Standard Spring Compliance the value corresponding to the provided reduced springcompliance value (via modulus and Poisson’s ratios) is directly displayed

Page 34

Page 35: 50091593-Manuale-BISAR

11. BISAR 3.0 Reports

11.1 The Block ReportAn example of the content and layout of the Block Report is presented on the next pages.

In this Block Report, the input and output for one system is compiled on one page. The outputcomprises the normal stresses and strains and uniaxial displacements at each selected positionin the structure. These normal stresses and strains are denoted by XX, YY, ZZ according to thedirections in the fixed Cartesian co-ordinate system. The uniaxial displacements arerespectively denoted as UX, UY and UZ.

Page 35

Page 36: 50091593-Manuale-BISAR

BISAR 3.0 – Block Report

Example Project

System: 1: Positions Between the Wheels and Under a Wheel

Structure LoadsModulus of Vertical Horizontal (Shear) Shear

Layer Thickness Elasticity Poisson’s Load Load Stress Load Stress Radius X-Coord Y-Coord AngleNumber (m) (MPa) Ratio Number (kN) (MPa) (kN) (MPa) (m) (m) (m) (Degrees)

1 0.300 5.000E+03 0.35 1 2.000E+01 5.774E-01 0.000E+00 0.000E+00 1.050E-01 0.000E+00 -1.575E-01 0.000E+002 0.200 1.000E+03 0.35 2 2.000E+01 5.774E-01 0.000E+00 0.000E+00 1.050E-01 0.000E+00 1.575E-01 0.000E+003 0.150 8.000E+02 0.354 2.000E+02 0.35

Stresses Strains DisplacementsPosition Layer X-Coord Y-Coord Depth XX YY ZZ XX YY ZZ UX UY UZNumber Number (m) (m) (m) (MPa) (MPa) (MPa) µstrain µstrain µstrain (µm) (µm) (µm)

1 1 0.000E+00 0.000E+00 1.500E-01 -1.475E-02 -9.446E-02 -1.290E-01 1.269E+01 -8.831E+00 -1.815E+01 0.000E+00 0.000E+00 9.900E+012 1 0.000E+00 0.000E+00 3.000E-01 1.919E-01 1.409E-01 -5.623E-02 3.246E+01 1.868E+01 -3.454E+01 0.000E+00 0.000E+00 9.516E+013 2 0.000E+00 0.000E+00 3.000E-01 1.416E-02 3.954E-03 -5.623E-02 3.246E+01 1.868E+01 -6.257E+01 0.000E+00 0.000E+00 9.516E+014 3 0.000E+00 0.000E+00 6.500E-01 2.704E-02 2.539E-02 -1.327E-02 2.849E+01 2.572E+01 -3.953E+01 0.000E+00 0.000E+00 7.978E+015 4 0.000E+00 0.000E+00 6.500E-01 1.399E-03 9.881E-04 -1.327E-02 2.849E+01 2.572E+01 -7.054E+01 0.000E+00 0.000E+00 7.978E+016 1 0.000E+00 -1.575E-01 1.500E-01 -2.084E-02 -3.776E-02 -2.388E-01 1.519E+01 1.062E+01 -4.366E+01 0.000E+00 -1.366E-01 9.778E+017 1 0.000E+00 -1.575E-01 3.000E-01 1.834E-01 1.450E-01 -5.453E-02 3.034E+01 1.999E+01 -3.389E+01 0.000E+00 -3.101E+00 9.284E+018 2 0.000E+00 -1.575E-01 3.000E-01 1.319E-02 5.514E-03 -5.453E-02 3.035E+01 1.998E+01 -6.108E+01 0.000E+00 -3.101E+00 9.284E+019 3 0.000E+00 -1.575E-01 6.500E-01 2.563E-02 2.317E-02 -1.262E-02 2.743E+01 2.327E+01 -3.712E+01 0.000E+00 -3.920E+00 7.845E+0110 4 0.000E+00 -1.575E-01 6.500E-01 1.314E-03 6.976E-04 -1.262E-02 2.743E+01 2.327E+01 -6.660E+01 0.000E+00 -3.920E+00 7.845E+01

Page 36

Calculated: 02-Dec-1997 13:18:52 Print Date: 02-Dec-1997 Page: 1

10

Page 37: 50091593-Manuale-BISAR

BISAR 3.0 – Block Report

Example Project

System: 2: Position Outside the Loads

Structure Loads

Modulus of Vertical Horizontal (Shear) Shear Layer Thickness Elasticity Poisson’s Load Load Stress Load Stress Radius X-Coord Y-Coord Angle

Number (m) (MPa) Ratio Number (kN) (MPa) (kN) (MPa) (m) (m) (m) (Degrees)

1 0.300 5.000E+03 0.35 1 2.000E+01 5.774E-01 0.000E+00 0.000E+00 1.050E-01 0.000E+00 -1.575E-01 0.000E+002 0.200 1.000E+03 0.35 2 2.000E+01 5.774E-01 0.000E+00 0.000E+00 1.050E-01 0.000E+00 1.575E-01 0.000E+003 0.150 8.000E+02 0.354 2.000E+02 0.35

Stresses Strains DisplacementsPosition Layer X-Coord Y-Coord Depth XX YY ZZ XX YY ZZ UX UY UZNumber Number (m) (m) (m) (MPa) (MPa) (MPa) µstrain µstrain µstrain (µm) (µm) (µm)

1 1 0.000E+00 -3.150E-01 1.500E-01 -1.583E-02 -6.004E-02 -6.675E-02 5.710E+00 -6.227E+00 -8.040E+00 0.000E+00 -6.995E-01 8.742E+012 1 0.000E+00 -3.150E-01 3.000E-01 1.222E-01 6.552E-02 -3.354E-02 2.219E+01 6.901E+00 -1.985E+01 0.000E+00 -5.374E+00 8.537E+013 2 0.000E+00 -3.150E-01 3.000E-01 9.982E-03 -1.345E-03 -3.354E-02 2.219E+01 6.901E+00 -3.657E+01 0.000E+00 -5.374E+00 8.537E+014 3 0.000E+00 -3.150E-01 6.500E-01 2.192E-02 1.736E-02 -1.087E-02 2.456E+01 1.687E+01 -3.078E+01 0.000E+00 -7.118E+00 7.478E+015 4 0.000E+00 -3.150E-01 6.500E-01 1.088E-03 -5.138E-05 -1.087E-02 2.456E+01 1.687E+01 -5.619E+01 0.000E+00 -7.118E+00 7.478E+01

Page 37

Calculated: 02-Dec-1997 13:18:52 Print Date: 02-Dec-1997 Page: 2

Page 38: 50091593-Manuale-BISAR

11.2 Detailed ReportExamples of the layout of ‘Detailed Report’ pages are presented on the next pages.

The first page of a System contains the input (layer structure and load configuration). The nextpages contain the detailed output per selected position (one position per page).

In contrast to previous versions (BISAR Mainframe and BISAR-PC 2.0) the ‘Detailed Report’includes display of units, be it without the prefixes used in input windows and Block Report.

The actual BISAR calculations to calculate the response of a load in terms of resulting stresses,strains and displacements at a certain position are carried out within a local cylindrical co-ordinate system (see section 2 and Appendix 2).

The following characteristics are given for each position

- the X, Y and Z - co-ordinates in the fixed Cartesian co-ordinate system- the distance between load-axis and position- the angle θ (theta) as an (indirect) measure for the radial direction of the position for the

individual combination of load and position (see Appendix 2) - for each load the displacements, normal and shear stresses and strains expressed in

directions of the local cylindrical co-ordinate system with the centre of the load as origin- the combined action of all the loads is expressed in terms of the (fixed) Cartesian co-

ordinate system

- total stresses, strains and displacements- principal values and directions of total stresses and strains.

The local cylindrical co-ordinate system is chosen such that

- the origin is at the centre of the load at the surface of the layered structure- the vertical direction is parallel to the Z-axis of the fixed Cartesian system- the radial direction and the tangential direction are in a horizontal plane perpendicular to the

vertical direction

The meaning of various notations for stresses (and similar for strains) is illustrated in Figure 1,which contains examples of the notation for type and direction of normal and shear stress withinthe fixed Cartesian co-ordinate system and a local cylindrical co-ordinate system. The origin forthe latter system is indicated as O’ (the X’-, Y’- and Z’- axes in Figure 1 are respectively parallelto the X-, Y- and Z-axes of the fixed Cartesian system).

Page 38

X

XX

rr

r

Z

XYshear

normal

Fixed XYZ-system Local cylindrical system

normalY

OX'

Z'

Y'

O'

σ

rηshear

η

σ σ

σ

Figure 1: Outline of directions of normal and shear stresses within both coordinate systems.

Page 39: 50091593-Manuale-BISAR

BISAR 3.0 – Detailed Report

Example Project

System: 1: Positions Between the Wheels and Under a Wheel

Page 39

Calculated: 02-Dec-1997 13:18:52 Print Date: 02-Dec-1997 Page: 1

Layer Young’s Poisson’s Shear SpringNumber Thickness (m) Modulus (Pa) Ratio Compliance (m3/N)

1 0.300 5.000E+09 0.35 0.000E+002 0.200 1.000E+09 0.35 0.000E+003 0.150 8.000E+08 0.35 0.000E+004 2.000E+08 0.35

Load Normal Shear Radius of Load Position Load Position ShearNumber Stress (Pa) Stress (Pa) Loaded Area (m) X (m) Y (m) Direction (°)

1 5.774E+05 0.000E+00 1.050E-01 0.000E+00 -1.575E-01 0.000E+002 5.774E+05 0.000E+00 1.050E-01 0.000E+00 1.575E-01 0.000E+00

Page 40: 50091593-Manuale-BISAR

BISAR 3.0 – Detailed Report

Example Project

System: 1: Positions Between the Wheels and Under a Wheel

Position Number: 1 Layer Number: 1 X Coord (m): 0.000E+00 Y Coord (m): 0.000E+00 Z Coord (m): 1.500E-01

Load Distance to Displacements (m) Stresses (Pa) StrainsNo. Load Axis (m) Theta (°) Radial Tangential Vertical Radial Tangential Vertical Rad./Tang. Rad./Vert. Tang./Vert. Radial Tangential Vertical Rad./Tang. Rad./Vert.Tang./Vert.

1 1.575E-01 9.001E+01 9.993E-07 0.000E+00 4.950E-05 -4.723E+04 -7.377E+03 -6.449E+04 0.000E+00 -7.877E+04 0.000E+00 -4.415E-06 6.345E-06 -9.075E-06 0.000E+00 -2.127E-05 0.000E+00

2 1.575E-01 -9.001E+01 9.993E-07 0.000E+00 4.950E-05 -4.723E+04 -7.377E+03 -6.449E+04 0.000E+00 -7.877E+04 0.000E+00 -4.415E-06 6.345E-06 -9.075E-06 0.000E+00 -2.127E-05 0.000E+00

Total Stresses (Pa) XX: -1.475E+04 YY: -9.446E+04 ZZ: -1.290E+05 YZ: 0.000E+00 XZ: 0.000E+00 XY: 0.000E+00Total Strains XX: 1.269E-05 YY: -8.831E-06 ZZ: -1.815E-05 YZ: 0.000E+00 XZ: 0.000E+00 XY: 0.000E+00Total Displacements (m) UX: 0.000E+00 UY: 0.000E+00 UZ: 9.900E-05

Principal Values and Directions of Total Stresses and Strains

Normal Normal Shear Shear X Y ZStress (Pa) Strain Stress (Pa) Strain Comp. Comp. Comp.

Maximum: -1.475E+04 1.269E-05 1.0000 0.0000 0.0000Minimax: -9.446E+04 -8.831E-06 0.0000 1.0000 0.0000Minimum: -1.290E+05 -1.815E-05 0.0000 0.0000 1.0000Maximum: 5.711E+04 1.542E-05 0.7071 0.0000 -0.7071

-7.186E+04 0.7071 0.0000 0.7071MiniMax: 3.985E+04 1.076E-05 0.7071 -0.7071 0.0000

-5.461E+04 0.7071 0.7071 0.0000Minimum: 1.726E+04 4.660E-06 0.0000 0.7071 -0.7071

-1.117E+05 0.0000 0.7071 0.7071

Strain Energy (J): 1.494E+00 Strain Energy of Distortion (J): 9.266E-01

Page 40

Calculated: 02-Dec-1997 13:18:52 Print Date: 02-Dec-1997 Page: 2

Page 41: 50091593-Manuale-BISAR

12. Error Messages

The following error messages apply:

Entry of Loads in Stress and Load Mode

Field Actual Error MessageVertical Stress The Vertical Stress Value must be greater than 0 and less than 10000Vertical Load The Vertical Load Value must be greater than 0 and less than 10000X Coordinate The X Coordinate Value should be between -99.9999 and 999.9999Y Coordinate The Y Coordinate Value should be between -99.9999 and 999.9999Horizontal Stress The Horizontal Stress Value should be between 0 and 9999.999Shear Direction The Shear Direction Value should be between 0 and 999.9

Entry of Loads in Load and Radius Mode

Field Actual Error MessageVertical Load The Vertical Load Value must be greater than 0 and less than 10000Radius The Radius Value must be greater than 0 and less than 1000X Coordinate The X Coordinate Value should be between -99.9999 and 999.9999Y Coordinate The Y Coordinate Value should be between -99.9999 and 999.9999Horizontal Load The Horizontal Load Value should be between 0 and 9999.999Shear Direction The Shear Direction Value should be between 0 and 999.9

Entry of Loads in Stress and Radius Mode

Field Actual Error MessageVertical Stress The Vertical Stress Value must be greater than 0 and less than 10000Radius The Radius Value must be greater than 0 and less than 1000X Coordinate The X Coordinate Value should be between -99.9999 and 999.9999Y Coordinate The Y Coordinate Value should be between -99.9999 and 999.9999Horizontal Stress The Horizontal Stress Value should be between 0 and 9999.999Shear Direction The Shear Direction Value should be between 0 and 999.9

Validation of Layers

Field Actual Error MessageThickness The Thickness Value should be greater than 0 and less than 100Modulus of Elasticity The Modulus of Elasticity Value should be greater than 0 and less than

1E20Poisson’s Ratio The Poisson’s Ratio Value should be greater than 0 and less than 1Spring Compliance The Spring Compliance Value should be between 0 and 1E+10

Validation of Positions

Field Actual Error MessageX Coordinate The X Coordinate Value should be between -99.9999 and 999.9999Y Coordinate The Y Coordinate Value should be between -99.9999 and 999.9999Z Coordinate The Z Coordinate Value should be between -99.9999 and 999.9999

Page 41

Page 42: 50091593-Manuale-BISAR

Appendix 1

BISAR Calculations with Slip between Layers(Shear Spring Compliance Concept)

A1.1 Theoretical Background

One of the possibilities of BISAR is the capability to account for (full or partial) slip. This type ofcalculation is made with aid of the shear spring compliance, a parameter which should not beconfused with the well-known friction coefficient.

Within BISAR, it is not possible to use the ‘classic’ friction coefficient, because its value differsfor static and dynamic conditions. Use of this parameters would require BISAR to be able tocope with discontinuities (step functions). The mathematics behind the BISAR model, however,assumes continuous relations for all its parameters.

To solve this problem, the designers of BISAR have developed the concept of shear springcompliance. In this approach the interface between two (horizontal) pavement layers isrepresented by an infinite thin inter-layer of which the strength is described by means of aspring compliance. Physically it assumes that the shear stresses at the interface cause arelative horizontal displacement of the two layers, which is proportional to the stresses acting atthe interface.

The physical definition of the standard shear spring compliance, AK, is given by

relative horizontal displacement of layersAK = [m3/N]

stresses acting at the interface

which relation is treated mathematically through the parameter α, defined as

in whicha = radius of the load, m E = modulus of the layer above the interface, Paν = Poisson’s Ratio of that layerα = friction parameter, with 0 ≤ α ≤ 1

(α = 0 means full friction, α = 1 means complete slip).

The reduced shear spring compliance, ALK expressed in m, is defined as

One of the values of AK and ALK is input for the BISAR program. The value of α, calledinterface friction, used in all computations is derived from the input (either AK or ALK).

The friction parameter α should not be considered as a classic friction coefficient. The interfacefriction parameter depends on the diameter of the applied load and is therefore not a purematerial property. Within calculations with loads of different diameters, different values for αapply for one ALK or AK value as physical characteristic for a specific layer interface. It is

Page 42

AKα =

1 + νAK + . a

E

αALK = .a

1 – α

Page 43: 50091593-Manuale-BISAR

therefore formally not correct to express a percentage of slip as a proportion of the springcompliance for full slip.

On the other hand, it remains difficult to assign or justify a specific value for AK (ALK).Therefore, it is recommended to always perform a series of calculations with different values forALK as a kind of sensitivity analysis. A numerical variation in ALK from zero to, say, 100 timesthe radius of the loaded area covers the range from full friction to (practically) full slip (α = 0.99).The physical meaning (see above definition of AK) of such input values should be considered inconnection with the moduli of the layers in the structure and the corresponding shear springcompliance (AK) values, with aid of the relation

Page 43

1 + νAK = ALK .

E

Page 44: 50091593-Manuale-BISAR

Appendix 2

The radial direction within fixed and local co-ordinate systems

The input for BISAR is expressed in terms of a fixed Cartesian co-ordinate system (X,Y,Z). Theactual BISAR calculations, however, to determine the response of a load at a certain position interms of resulting stresses, strains and displacements are carried out in a local cylindrical co-ordinate system (r,θ,z) for each load. An outline of both systems is given in Figure 2-1. L is thecentre of a load in the X-Y plane at the top of the structure and is the origin of the localcylindrical system. P corresponds to an arbitrary position in the structure, with P’ as projectionof P on the surface plane.

Page 44

Fixed XYZ-system Local cylindrical system

P

P'

X

Z Z'L (xL,yL,0)P' (xP,yP,0)P (xP,yP,zP)

L (0,0,0)P' (r,Θ,0)P (r,Θ,zP)

Y

OO'

P'

P

LL

r

Θ

Figure 2-1 Outline of coordinate systems within BISAR.

O

Y

X

Lr

P'

η

Θ

Tangential direction Radial direction

xPxL

yP

yL

(xP,yP,0)(r,Θ,0)

Figure 2-2 Outline of the directions in the cylindrical coordinate system for a specificcombination of load and position (loading without shear force).

Page 45: 50091593-Manuale-BISAR

The so-called ‘Detailed Report’ contains a value for the angle θ (theta), which is internally usedby BISAR. This appendix explains the relation between the radial direction with respect to thefixed Cartesian Co-ordinate system (defined by the user) and the radial direction used andreported by BISAR.

The situation in case of vertical loading, without applying any shear force, is outlined inFigure 2-2.

The radial direction for a load and position combination with respect to the fixed Cartesian Co-ordinate system is given by the (internal BISAR) value η, the angle between the intersectionline of position and the centre of the load with the positive X-axis.

In case of vertical loading

θ = η

so the BISAR output θ (theta) is equal to the direction with the (fixed) positive X-axis of the userdefined Cartesian co-ordinate system.

When applying a horizontal shear force on the loading, the situation is more complex, becausethe value of θ in the output now also depends on the direction of the horizontal loading. Thesituation is illustrated in Figure 2-3.

The radial direction (angle θ in the Detailed Report) used to perform the calculations within thelocal cylindrical co-ordinate system is now taken with respect to the direction of the shear force.This direction is indicated by ψ, the angle between the shear direction and the positive X-axis(input in the load screen). In other words, the value for θ varies with varying shear direction,while from a designers point of view the radial direction for a specific combination of load andposition does not change.

As illustrated in Figure 2-3, the latter direction (with respect to the fixed Cartesian Co-ordinatesystem) and indicated by η, can be found from

η = θ = ψ

Page 45

0

Y

X

L

r P'

η

η

Θ

Tangential direction Radial direction

Shear direction

xPxL

yP

yLΨ

(xP,y

P,0)

(r,Θ,0)

Figure 2-3 Outline of the directions in the cylindrical coordinate system for a specificcombination of load and position (loading with shear force).

Page 46: 50091593-Manuale-BISAR

Appendix 3

Overview of Units and Prefixes

Parameter Units

Input Screens Block Report Detailed Report

Load kN kN -Radius m m mStress MPa MPa PaCo-ordinates m m mShear Direction degrees degrees degreesThickness m m mModulus MPa MPa PaPoisson’s Ratio - - -Spring Compliance m3/N m3/N m3/N - (reduced) m m mStrains - µm/m m/mDisplacements - µm mDistance to load - - mTheta - - degreesStrain Energy - - J - of Distortion - - J

Page 46

Page 47: 50091593-Manuale-BISAR

References

1. D.L. de Jong, M.F.G. Peutz and A.R. Korswagen, Computer Program BISAR, Layeredsystems under nornal and tangential surface loads, AMSR.0006.73.

2. R.C. Koole, C.P. Valkering and F.D.R. Stapel, Development of Pavement Design Program forUse on Personal Computer, Paper presented at the 5th Conference of Asphalt Pavements forSouthern Africa, Swaziland, 5th-9th June 1989.

Page 47