5000 Series - arcadiainc.com

14
INTERLOCKERS B-JAMB 4 1 4 " 2" 4 3 4 " EXT. INT. 4 3 4 " 4 3 4 " 2" 4 3 4 " STACK TRANSOM SILL over HEAD FIXED JAMB LEFT FIXED RIGHT FIXED TRANSOM JAMB 3 4 " 4 3 4 " 1 1 2 " EXTERIOR INTERIOR FIXED JAMB TRANSOM HEAD O O Over OLXO CONFIGURATION EXTERIOR ELEVATION (INSIDE SLIDER SHOWN OUTSIDE SLIDER-AVAILABLE) X O O X O O OLXO OXRO NOT SHOWN X O O 1 2 3 4 5 6 7 8 9 4 1 2 5 6 3 7 8 9 Recessed Nail Fin Option INTERIOR 2 1 2 " 4 3 4 " 3 4 " 2" 6 1 8 " 4 3 4 " 2 1 4 " 2" 4 3 4 " EXTERIOR Flush Flange Option EXTERIOR EXTERIOR TRANSOM JAMB EXT. INT. 2" B/L SILL As of: 09/24/21 ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf Scale: Function: Description: Detail: OF SHEET 5000 Series Sliding Doors Entrances Varies 3" = 1'-0" 1 14 40 1/2" A.F.F. TO CENTER OF PULL/PUSH 49 7/8" TO CENTER OF LOCKSET

Transcript of 5000 Series - arcadiainc.com

Page 1: 5000 Series - arcadiainc.com

INTERLOCKERSB-JAMB

414"

2"

434"

EXT. INT.

434"

434"

2"

434"

STACKTRANSOMSILL over

HEAD

FIXED JAMB

LEFTFIXED

RIGHTFIXED

TRANSOMJAMB

34"

434"

112"

EXTERIOR

INTERIOR

FIXED JAMB

TRANSOMHEAD O

O Over OLXO CONFIGURATIONEXTERIOR ELEVATION

(INSIDE SLIDER SHOWNOUTSIDE SLIDER-AVAILABLE)

XO

O X

O

O

OLXO

OXRONOT SHOWNX

O

O

1

2

3

4 5

6 7 8 9

41

2

5

6

3

7 8 9

RecessedNail FinOption

INTERIOR21

2"

434"

34"

2"618"

434"

214"

2"

434"

EXTERIORFlush FlangeOption

EXTERIOR

EXTERIOR

TRANSOMJAMB

EXT. INT.

2" B/LSILL

As of: 09/24/21ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01 ULT 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 1 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 2: 5000 Series - arcadiainc.com

EXT. INT.

HEAD

EXTERIOR

INTERIOR

LATCH JAMBINTERLOCKERSFIXED JAMB MULLION

414"

2"

434"

EXTERIOR

OOX CONFIGURATIONEXTERIOR ELEVATION

(INSIDE SLIDER SHOWNOUTSIDE SLIDER-AVAILABLE)

XO

XO

O

O

434"

34"

334"

1

2

3 4 5 6

1

3

2

4 5 6

118" 2"

418"

RecessedNail FinOption

FlushFlangeOption

212"

158"

Nail Fin11

2"

X O

X O

O

O

XOO CONFIGURATION

EXTERIOR

2" B/LSILL

As of: 09/24/21ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01 ULT 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 2 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 3: 5000 Series - arcadiainc.com

EXTERIOR

INTERIOR

LATCH JAMB

HEAD

INTERLOCKERS

INT.EXT.

INT.EXT.

FIXED JAMB

OX CONFIGURATIONEXTERIOR ELEVATION

(OUTSIDE SLIDER SHOWNINSIDE SLIDER-AVAILABLE)

(INTERIOR SCREEN)

XO

XO

278"

118"

512"

51316"

212"

158"

318"

512"

434"

414"

2"1"

118"

434"

212"

118"

2 116"

2"

512"

418"

234"

1

2

3 4 5

1

3

2

4 5

RecessedNail FinOption

FlushFlangeOption

X O

X O

XO CONFIGURATION

EXTERIOR

EXTERIOR

2" B/LSILL

As of: 09/24/21ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01 ULT 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 3 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 4: 5000 Series - arcadiainc.com

HEAD

B-JAMBINTERLOCKERS FIXED JAMB

414"

2"

434"

EXT. INT.

EXTERIOR

INTERIOR

434"

34"

2"

5 116"

618"

FIXED JAMB

OXRO CONFIGURATIONEXTERIOR ELEVATION

(INSIDE SLIDER SHOWNOUTSIDE SLIDER-AVAILABLE)

XO

O X

O

O

1

2

3 4 5 6

1

3

2

4 5 6

FlushFlangeOption

RecessedNail FinOption

2"

434"

212"

158"

OUTSIDE

INSIDE

Nail Fin11

2"

Head Filler

XO

OX

O

O

OLXO CONFIGURATION

EXTERIOR EXTERIOR

2" B/LSILL

As of: 09/24/21ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01 ULT 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 4 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 5: 5000 Series - arcadiainc.com

2" B/LSILL

HEAD

B-JAMB

EXT. INT.

FIXED JAMB

212"

158"

434"3

4"

414"

2"

434"

INTERLOCKERS FIXED JAMB

EXTERIOR

OXRO CONFIGURATIONEXTERIOR ELEVATION

(OUTSIDE SLIDER SHOWNINSIDE SLIDER-AVAILABLE)

O X O

XO O

1

2

3 4 5 6

1

3

2

4 5 6

EXTERIOR

Nail Fin

Head Filler

INTERIOR

618"

RecessedNail FinOption

2"

434"

OXO

X OO

OLXO CONFIGURATION

EXTERIOR

FlushFlangeOption

As of: 09/24/21ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01 ULT 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 5 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 6: 5000 Series - arcadiainc.com

2" B/LSILL

HEAD

MEETING STILES

414"

2"

434"

EXT. INT.

EXTERIOR

INTERIOR2" 21

2"

434"

34"

EXTERIOR

OXXO CONFIGURATIONEXTERIOR ELEVATION

(INSIDE SLIDER SHOWNOUTSIDE SLIDER-AVAILABLE)

XO

O X

X

X

O

O

INTERLOCKERSFIXED JAMB

434"

34"

2"

EXT.

INTERLOCKERS FIXED JAMB

1

2

3 4 5 6 7

1

3

2

4 5 6 7

RecessedNail FinOption

614"

212"

158"

Nail Fin11

2"

INT.

(ACTIVE)

Head Filler

FlushFlangeOption

As of: 09/24/21ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01 ULT 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 6 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 7: 5000 Series - arcadiainc.com

HEAD

EXT. INT.

EXTERIOR

318"

512"

434"

414"

2"1"

EXT. INT.

OXXO CONFIGURATIONEXTERIOR ELEVATION

(OUTSIDE SLIDER SHOWNINSIDE SLIDER-AVAILABLE)

- HI LOAD MEETING STILE & HI LOAD INTERLOCKERS

XO

O X

X

X

O

O

WITH INTERIOR SCREEN PANELS

2

1

3

2

4 5 6 7

HI-LOADINTERLOCKERS HI-LOAD

MEETING STILES

EXTERIOR

INTERIOR

FIXED JAMB FIXED JAMB

118"

434"

212"

HI-LOADINTERLOCKERS

3

4

5

6

7

RecessedNail Fin71

8"

278"

118"

512"

51316"

212"

158" Head Filler

(ACTIVE)

1

8"

312"

FlushFlangeOption

2" B/LSILL

As of: 09/24/21ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01 ULT 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 7 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 8: 5000 Series - arcadiainc.com

EXT. INT.

HEAD

INTERLOCKERSLATCH JAMB FIXED JAMB

EXTERIOR

INTERIOR

EXTERIOR

XO CONFIGURATIONEXTERIOR ELEVATION

(INSIDE SLIDER SHOWNOUTSIDE SLIDER-AVAILABLE)

(1/4" GLAZING)

X

X O

O

1

2

3 4 5

1

3

2

4 5

434"

34"

212"

158"

414"

2"

434"

434"

34"

118"

212"

2"418"

5 116"

FlushFlangeOption

RecessedNail FinOption

X

XO

O

OX CONFIGURATION

EXTERIOR

5 916"

2"

INT.

434"

EXT.

OPTIONAL5000 JUMBO

BOTTOM RAILSw/ 2" B/L SILL

2

Head Filler

2" B/LSILL

HEAD

434"

34"

212"

158"1

2

EXT. INT.

414"

2"

434"

1/4" Aluminum Glass Reducer Insert for 1" Panels Extrusion 1/4" Reducing Vinyl for 1" Panels Extrusion

2" B/LSILL

1/4" Reducing Vinyl for 1" Panels Extrusion

As of: 09/24/21ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01 ULT 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 8 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 9: 5000 Series - arcadiainc.com

EXT. INT.

HEAD

INTERIOR

LATCH JAMB INTERLOCKERS FIXED JAMB

414"

2"

434"

418"

434"

34"

212"

434"

34"

2"

EXTERIOR

XO CONFIGURATIONEXTERIOR ELEVATION

(INSIDE SLIDER SHOWNOUTSIDE SLIDER-AVAILABLE)

X O

X O

1

2

3 4 5

1

3

2

4 5

RecessedNail FinOption

FlushFlangeOption

212"

158"

OUTSIDE

INSIDE

Nail Fin11

2"

EXTERIOR

Head Filler

XO

EXTERIOR

XO

OX CONFIGURATION

6

2" MUNTIN (5000952)

6

2"

(OPTIONAL)

2" B/LSILL

As of: 09/24/21ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01 ULT 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 9 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 10: 5000 Series - arcadiainc.com

EXT. INT.

HEAD

EXTERIOR

INTERIOR

LATCH JAMB INTERLOCKERS FIXED JAMBMULLION

414"

2"

434"

2"

358"

334"

418"

434"

34"

212"

434"

34"

2"

EXTERIOR

XOO CONFIGURATIONEXTERIOR ELEVATION

(INSIDE SLIDER SHOWNOUTSIDE SLIDER-AVAILABLE)

X O

X O

O

O

1

2

3 4 5 6

1

3

2

4 5 6

RecessedNail FinOption

FlushFlangeOption

212"

158"

OUTSIDE

INSIDE

Nail Fin11

2"

XO O

XOO

EXTERIOR

OOX CONFIGURATION

Head Filler

2" B/LSILL

As of: 09/24/21ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01 ULT 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 10 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 11: 5000 Series - arcadiainc.com

EXTERIOR

INTERIOR

LATCH JAMB

HEAD

INTERLOCKERS

EXTERIOR

XOO CONFIGURATIONEXTERIOR ELEVATION

(OUTSIDE SLIDER SHOWNINSIDE SLIDER-AVAILABLE)

X O

X O

O

O

212"

158"

434"

34"

414"

2"

434"

INT.EXT.

MULLION FIXED JAMB

434"

418"

5 116"

2"

334"

2"

31116"

212"

1

2

3 4 5 6

1

3

2

4 5 6

RecessedNail FinOption

FlushFlangeOption

Head Filler

XO

XO

O

O

EXTERIOR

OOX CONFIGURATION

2" B/LSILL

As of: 09/24/21ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01 ULT 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 11 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 12: 5000 Series - arcadiainc.com

EXTERIOR

INTERIOR

HEAD

EXTERIOR

O UNIT CONFIGURATIONEXTERIOR ELEVATION

O

O

414"

2"

434"

INT.EXT.

FIXED "O"UNIT JAMB

434"

2" 118"

1

2

3 4

1

3

2

4

FIXED "O"UNIT JAMB

RecessedNail FinOption

FlushFlangeOption

212"

158"

OUTSIDE

INSIDE

Nail Fin11

2"

Head Filler

4"

EXTERIOR

INTERIOR

FIXED "O"UNIT JAMB

FIXED "O"UNIT JAMB(4" FRAME) (4" FRAME)

HEAD

414"

238"

INT.EXT.

1

2

2 3/8" B/L4" FRAME

SILL

212"

158"

OUTSIDE

INSIDE

Head Filler

4"

4"

2" 118"

4" FRAME

2" B/LSILL

As of: 09/24/21ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01 ULT 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 12 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 13: 5000 Series - arcadiainc.com

2"

434"

2" B/L SILL

238"

434"

2 3/8" B/L SILL

3"

434"

118"

434"

1 1/8" B/L SILL

58"

434"

5/8" FLUSH SILL

3" B/L SILL

SERIES 5000 ACCESSSORIES - OPTIONAL

HEAD withFLUSH FLANGE

312"

434"

4 716"

212"

INT.EXT.212"

158"

434"

INT.EXT.

12"

5 316"

HEAD with 2 PcHEAD COMP

EXTERIOR

INTERIOR

518"

434"

2"

5 316"

LATCH JAMB with2 Pc JAMB COMP

6"

1"34"

"Z" TRACKEXTENDED SUB SILL

212"

6 316"

518"43

4"11

8"

3 Pc PRESSURE PLATETO MULL TWO (2)

5000 DOOR TOGETHER

EXTERIOR

INTERIOR

5"

1"

"L" SHAPEEXTENDED SUB SILL

HI-LOADINTERLOCKERS

MODERN

Head Filler

Head Filler 4" HEAD

2 3/8" B/L SILL - 4" FRAME

4"

238"

4"

4" JAMB

158"

4"

118"

534"

2"

INT.EXT.

EXTERIOR

INTERIOR

118"

4"1 1/8" B/L SILL - 4" FRAME

58"

4"5/8" FLUSH SILL - 4" FRAME

5 916"

2"

INT.

434"

EXT.

5000 JUMBOBOTTOM RAILSw/ 2" B/L SILL

HI-LOADINTERLOCKERS

DESIGNER

1038"

2"

434"

DOUBLE STACKED JUMBOBOTTOM RAIL(10")

w/ 2" B/L SILL

4" JAMB COMP(OPTIONAL)

4" (2 PC.) HEAD COMP(OPTIONAL)41

2"

(OPTIONAL)

SNAP TRIMINSIDE/OUTSIDE BASE

418"

118"

OUTSIDE

INSIDE

FLUSH PULLS (OPTIONAL)

As of: 09/24/21ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01 ULT 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 13 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 14: 5000 Series - arcadiainc.com

Inte

rior

Inte

rior

9500095Turnlever w/ Escutcheon

(Use Only withMS+1847 Lock)

9500120 MS+1847

Stainless SteelMortise Lock

9500111 Stainless Steel

Magnum PrecisionTandem Rollers

(Optional 9500111PWPolymer Wheel)

9500040MS+1850 Mortise Lock/w SS Hook

(Optional 9500041 MS+1950 AllStainless SteelMortise Lock)

9500063/A Adams Rite Locking

Flush PullHandle Set(2 Pieces)

Exterior/Interior

* Also availableas Dummy FlushPull Handle Set

(No Locking Mechanism)

9500054/5MS+1850 Mortise

LockFaceplate

950920/30/40I - 5/16 Plastic Push Plug

9500106/73/8" Extruded Cylinder

Trim Ring

9500090S S Track Cap

9501118 InterlockerNotch Pile Dust Pad

0.270 Ht. x 3/4" W. x 2" L.

9501114 LM StileBottom Pile Dust Pad

0.500 Ht. x 5/8" W x 1 1/16" L

Exte

rior

950895/6/7I - 3/8 Plastic Push Plug

9500100R/1R BrassLock Thumbturn

9500103R/4R BrassLock Keyed Cylinder

5000533Head Bumper-

1 1/4" or 1 1/2" Wide

Exte

rior

Exte

rior

Door Hardware Components

9500045 (OXXO Only)

Fixed InterlockerRubber Block

950900/10/15I - 7/16 Plastic

Push Plug

9500043Rubber Bumper-1/8"

for Latch Stile

9500017Fixed Panel

Isolator

9500992/4/6Nylon LatchHole Cover

(For Latch Jamb)

9500044EPDM Bottom Rail

Water Flap (Flocked)

95002101 1/8" Marine Glazing Gasket

Weatherstrip & Marine Glazing Gasket

95011090.270 x 0.275

Q-Lon Foam Weatherstrip

9501108AME0.187 x 0.250

Fin-Pile Weatherstrip

95011130.270 x 0.220

Fin-Pile Weatherstrip

9500200A1" Marine Glazing Gasket

9523333/16" or 1/4" Marine

Glazing Gasket9500260

3/16" or 1/4" ReducingGlazing Gasket

9501582/5Screen Door

Flush PullHandle Set

(D250Screens)

9500063D/EKeyed Exterior

Single FlushPull Handle

9501577Roller Spacer

(D250 Screens)

9501573Screen Roller

9500075/6Edge Finger Pull

Interior

9500125/63/4" Dia.Wire Pull

Handle Set

9500080PSC-Sill Neoprene Pad

5/16" Ht. x 7/16" W. x 2" L.

95011250.270 x 0.190

Fin-Pile Weatherstrip

4"

9500112 Heavy Duty

Precision S STandem Rollers

(Optional95000112PW

Polymer Wheel)

95011232" Sill Backleg Pad

.270" Ht. x .835" W. x 2" L.

95011222 3/8" Sill Backleg Pad

.270" Ht. x 1 1/4" W. x 2" L.

95011243" Sill Backleg Pad

.270" Ht. x 1.925" W. x 2" L.

9500204-1 1/32"9500205-1 1/16"

Marine Glazing Gasket

9505503-3/8"9505502-1/2"

Reducing Glazing Gasket

Inte

rior

9500135/B/C/SS Single Flush

Handle

FUTURA SERIES

9500140/B/C/SSExterior / InteriorRecessed Flush

Handles

950998OX950998XOS S Flush

Slide & Lock

Exte

rior

1 13/16" Wheels

3" Wheels

9500032Interlockers

Isolator

9501127Sliding Interlocker

Bottom Pile Dust Pad0.270" Ht. x 1 1/4" W x 1 1/2" L

9501128 - Sliding InterlockerAlum. Plate

1/16" Ht. x 1 1/4" W x 1 1/2" LN/A - Sliding Interlocker

2 Face Tape1/32" Ht. x 1 1/4" W x 1 1/2" L

9500996S.S. Strike

Plate

9500038Rubber Bumper-3/16"

for Latch Stile9500026

Rubber Bumper-1/4"for Latch Stile

9500127/83/4" Dia.

Single Wire Pull

As of: 09/24/21ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01 ULT 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 14 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

AutoCAD SHX Text
OPEN
AutoCAD SHX Text
ON
AutoCAD SHX Text
arcadia
AutoCAD SHX Text
arcadia