5.0 Ton Split System Heat Pump - 1 Phase
Transcript of 5.0 Ton Split System Heat Pump - 1 Phase
Product Specifications OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZR.L. AMPS - L.R. AMPSFACTORY INSTALLED
START COMPONENTS INSULATION/SOUND BLANKETCOMPRESSOR HEAT
OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS
OUTDOOR COIL — TYPE
ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ. CHARGING SPECIFICATIONSUBCOOLING
DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.)
J4HP6061A1000AA
TAG: _________________________________
5.0 Ton Split System Heat Pump - 1 Phase J4HP6061A1000AA
S UBMIT TAL
J4HP6061A1000AA
208/230/1/603245
SCROLL1 - 2
208/230/1/6023-118
PROPELLER23-1/16 - 1DIRECT - 1
33001 - 1/31050
208/230/1/602.6
PLATE FIN2.8 - 19
18.49/32
ORIFICE
10 LBS. - 14 OZ. YES1-1/83/8
8º FH X W X D
38-63/64x30-1/5x30-1/5
240227
NONO
AIR DISCHARGE: ALLOW 60” MINIMUM CLEARANCE.
CONTROL WIRING7/8” (22.2mm)
KNOCKOUT1-11/32”(34.5mm)
LIQUID LINECONNECTION
SERVICEFITTINGSERVICE
FITTING
POWER WIRINGSEE DETAIL A
DETAIL A
HOLE1-3/32”(27.8mm)
SERVICE ACCESSALLOW 24” CLEARANCE
AIR INLETSLOUVERED PANELSALLOW 12”MINIMUMCLEARANCE
NOTE: GRILL APPEARANCE MAY VARY.
W
VAPOR LINE CONNECTION
J4HP6061A1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
843 (33-3/16) 740 (29-1/8) 3/8 7/8
NOTE: All dimensions are in mm/inches.
740 (29-1/8)
YES
A
Literature Order Number SS-PRC007-EN
File Number —
Supersedes SS-PRC007-EN 2/02
Stocking Location PI Louisville & Webb/Mason Houston
has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
MechanicalSpecification Options
Optional accessoriesLiquid line drier —
GeneralThe J4HP60 is fully charged from the factory. This unit is designed to operateat outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is certified to ETL. Exterior is designed for outdoor application.
CasingUnit casing is constructed of heavy gauge, Galvanized steel and painted with a weather-resistant powder paint on all grilles, panels, pre-paint on all other panels. And had 500-hours salt spray tested.
Refrigerant ControlsRefrigeration system controls include condenserfan, compressor contactor, high pressure switch and low pressure switch. The factory installed crankcase heat can protect compress when it stands by.
Two-stage CompressorFeatures include low vibration and noise.
Condenser CoilThe outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grille panels.
It is used to filter out impurities and water in the system, ensures system clean and dry.
OXBOX