5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

54
HUAWEI TECHNOLOGIES Co., Ltd. www.huawei.com HUAWEI Confidential Internal Use (Only) Dec. 31 2006 GSM BSS Training Team CNE040613040006 HUAWEI BSC6000 Software Commissioning ISSUE 1.0

Transcript of 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

Page 1: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd.

www.huawei.com

HUAWEI Confidential

Internal Use (Only) Dec. 31 2006

GSM BSS Training Team

CNE040613040006 HUAWEI BSC6000

Software Commissioning

ISSUE 1.0

Page 2: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 2HUAWEI Confidential

This presentation describes the preparations

and process for commissioning of the

HUAWEI BSC6000. It also describes the

verification of data services for the Abis

interface, Ater interface, A interface, and Pb

interface.

Page 3: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 3HUAWEI Confidential

Reference

HUAWEI BSC6000 Base Station

Controller Software Installation Guide

HUAWEI BSC6000 Base Station

Controller Commissioning Guide

Page 4: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 4HUAWEI Confidential

After learning the course, you can familiarize

yourself with BSC6000 commissioning preparations BSC6000 commissioning process Data verification methods for BSC interfaces BSC6000 service verification

Page 5: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 5HUAWEI Confidential

Chapter 1 Overview of Commissioning

Chapter 2 Commissioning of Interface

Chapter 3 Service Verification

Page 6: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 6HUAWEI Confidential

Typical Networking

The following figure shows a typical networking structure for the BSC6000:

Alarm box

LMT

MS BTS

GBAM

BSC6000

LAN Switch

MSC

PCU

LMT

Um Abis A

M2000

Page 7: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 7HUAWEI Confidential

Overview of Commissioning for BSC6000

Keep the following installation disks ready before the commissioning OMU software installation disk of the correct version LMT software installation disk of the correct version

Keep the following License file ready The License file that matches the office configuration has been requested

by Huawei technical support engineers

Keep configuration data ready

According to the HUAWEI BSC6000 Base Station Controller Data

Configuration Guide, keep the following data ready and correct: Board data Abis/Ater/A/Pb interface data Other related commissioning data

Page 8: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 8HUAWEI Confidential

Overview of Commissioning for BSC6000

Preparations for equipment

A minimum of one BTS is connected to the BSC6000. The

commissioning of the BTS is completed and the BTS can provide the

basic functions.

A minimum of one MSC is connected to the BSC6000. The

commissioning of the MSC is completed and the MSC can provide the

basic functions.

A minimum of one PCU is connected to the BSC6000. The

commissioning of the PCU is completed and the PCU can provide

basic PS functions.

Three single-mode MSs and one dual-mode MS used for testing are

ready and subscribed in the HLR.

Page 9: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 9HUAWEI Confidential

Chapter 1 Overview of Commissioning

Chapter 2 Commissioning of Interface

Chapter 3 Service Verification

Page 10: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 10HUAWEI Confidential

Process of System Commissioning

The commissioning process for the BSC6000 is as follows according

to priority:

Load the BSC host software

Load the BTS software

Verify the Abis interface

Verify the Ater interface

Verify the A interface

Verify the Pb interface

Connect the BSC6000 to the M2000

Refer to the presentation “HUAWEI BSC6000 Software Management”

for steps of loading BSC host software and BTS software.

Page 11: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Loading BSC Host Software

Ensure the following condition before

loading the BSC host software:

The BSC host software (all files in \

BSC6000\bscswm\area1\software)

exists under the directory of LMT

Installation Directory\Common\SWM\

Software.

The process of loading the BSC host

software is shown on the right.

Download software

Check GBAM version area

Load software

Activate software

Query board software

Query board information

Page 12: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Loading BTS Software

Ensure the following conditions before

loading the BTS software:

The BTS software exists in the related

directory of the LMT.

The BSC and the BTS are correctly

connected and the operation and

maintenance unit (OMU) of the BTS is

operational.

The process of loading the BTS software

is shown on the right.

Download BTS software

Configure BTS software

Load BTS software

Query BTS properties

Activate BTS software

Query board information

Page 13: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 13HUAWEI Confidential

Commissioning for BSC

The commissioning for the BSC comprises the following operations

without precedence:

Perform active/standby switchover

Query the License

Process alarms

Page 14: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 14HUAWEI Confidential

Purpose

To check whether the switchover function of active and standby boards is operational.

Procedure

Choose the menu BSC Maintenance > Maintain Device > Switch Over BSC Board .

Perform active/standby switchover tests for all boards that work in active/standby mode.

Perform active/standby switchover once again to restore the status of the active and

standby boards.

Performing Active/Standby Switchover

Page 15: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 15HUAWEI Confidential

Querying License

Purpose

To check whether the feature services based on the License file are valid.

Procedure

Choose the menu BSC Maintenance > Maintain License > Query License and

click Query in the Query License window.

The query results are displayed in the list.

Page 16: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 16HUAWEI Confidential

Purpose

To complete the processing of real-time alarms before the interface commissioning.

Procedure

Choose Alarm Maintenance> Browse Alarm to query real-time alarms.

Process each alarm according to the alarm processing steps in Online Help.

Processing Alarms

Page 17: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 17HUAWEI Confidential

Verifying Abis Interface

Ensure the following conditions before

verifying the Abis interface:

The BSC commissioning is passed.

The physical transmission between the

BSC and the BTS is connected.

The commissioning for the BTS used for

testing the Abis interface is completed

and the BTS is in “cell to be set up”

state.

The process of verifying the Abis

interface is shown on the right.

Verify physical link

Verify management plane link

Verify user plane channel

Process alarms

Page 18: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 18HUAWEI Confidential

Purpose

To check whether the physical link of the Abis interface is operational when E1/T1

bears the Abis interface.

Procedure

Choose the menu BSC Maintenance > Maintain Transmission and Signaling >

Query Interface Board Port State .

The link information is displayed in the following figure:

Verifying Physical Link

Page 19: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 19HUAWEI Confidential

Purpose

To check whether the management plane link (OML) between the BSC and the BTS

is operational.

Procedure: Choose the menu BSC Maintenance > Maintain Transmission and Signaling

> Maintain LAPD Link.

Query the OML of the related BTS.

Verifying Management Plane Link

Page 20: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 20HUAWEI Confidential

Purpose

To check whether the control plane link (RSL) between the BSC and the BTS is

operational.

Procedure

Choose the menu BSC Maintenance > Maintain Transmission and Signaling

> Maintain LAPD Link..

Query the RSL of the related BTS.

Verifying Control Plane Link

Page 21: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 21HUAWEI Confidential

Purpose

To check whether the user plane

channel between the BSC and the BTS

is operational.

Procedure

Choose the menu BSC Maintenance

> Maintain User Resource > Query

Abis Interface Timeslot State. to view

the following information.

Verifying User Plane Channel

Page 22: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 22HUAWEI Confidential

Verifying Ater Interface

Ensure the following conditions

before verifying the Ater interface for

the remote GTCS:

The BSC commissioning is passed.

The physical transmission between

the GMPS/GEPS and the GTCS is

connected.

The process of verifying the Ater

interface is shown on the right.

Verify managementplane link

Verify controlplane link

Verify userplane channel

Process alarms

Verify physical link

Verify user planechannel

Process alarms

GTCS remote configuration

GTCS localconfiguration

Page 23: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 23HUAWEI Confidential

Purpose

To check whether the physical link of the Ater interface is operational when E1/T1

bears the Ater interface (GTCS is locally configured).

Procedure

Search the subrack, slot, and port information for the Ater link to be verified.

For example, Ater connection channel 0 corresponds to BM subrack 0, BM slot

16, BM port 0, TC subrack 3, TC slot 16, and TC port 0.

Verifying Physical Link

Page 24: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 24HUAWEI Confidential

Verifying Physical Link

Procedure

Choose the menu BSC

Maintenance > Maintain

Transmission and

Signaling > Query Interface

Board Port State .

If the status of port 1 in slot

14 of subrack 0 and the

status of port 1 in slot 14 of

subrack 5 are normal, the

Ater connection channel 0 is

operational.

Page 25: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 25HUAWEI Confidential

Purpose

To check whether the user plane channel of the Ater interface is operational when

E1/T1 bears the Ater interface (GTCS is locally configured).

Procedure

Choose the menu BSC Maintenance > Maintain User Resource > Query Ater

Interface Timeslot State .

Type parameters in the query interface to query the timeslot status.

Verifying User Plane Channel

Page 26: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 26HUAWEI Confidential

Verifying Management Plane Link

Purpose

To check whether the

management plane link of the Ater

interface is operational when the

GTCS is locally configured.

Procedure

Choose the menu BSC

Maintenance > Maintain

Transmission and Signaling >

Query Ater OML State .

Page 27: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 27HUAWEI Confidential

Verifying A Interface

Ensure the following conditions before verifying

the A interface:

The BSC commissioning is passed.

The physical transmission between the BSC and

the MSC is connected.

The MSC is operational.

The process of verifying the A interface is shown

on the right.

Verify physical link

Verify control plane link

Verify user plane channel

Process alarms

Page 28: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 28HUAWEI Confidential

Verifying Physical Link

Purpose

To check whether the physical

link of the A interface is

operational when E1/T1 bears

the A interface.

Procedure

Step 1: In the main

interface, select the tab

BSC Information.

Page 29: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 29HUAWEI Confidential

Verifying Physical Link

Procedure

Step 2: Click the button E1 Interface in the previous window.

The subrack NO., slot NO., and port NO. of the A interface E1 are displayed in

the following interface.

Page 30: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 30HUAWEI Confidential

Verifying Physical Link

Procedure

Step 3: Choose the menu BSC Maintenance > Maintain Transmission and

Signaling > Query Interface Board Port State .

In the displayed interface, type the obtained subrack NO., slot NO., and port NO.

of the A interface E1.

Page 31: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 31HUAWEI Confidential

Verifying Control Plane Link

Purpose

To check whether the control plane link of the A interface is operational.

The control plane link indicates NO.7 transmission link. It can be categorized into

MTP2 link, MTP3 link, and SCCP link.

The MTP2 is processed by the GEIUT board in the GEPS subrack. The MTP3

and SCCP are processed by the GXPUM board in the GEPS subrack.

The link status is queried in the sequence of MTP2 link, MTP3 link, and SCCP

link.

Page 32: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 32HUAWEI Confidential

Verifying Control Plane Link

Procedure

Step 1: In the main interface, select the tab BSC information.

Page 33: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 33HUAWEI Confidential

Verifying Control Plane Link

Procedure

Step 2: Click the button SS7 Signaling Link in the previous window.

The obtained Ater Connection Channel Index NO. is 0. The related

MTP2 is processed by CPU 0 of the GXPUM in slot 0.

Page 34: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 34HUAWEI Confidential

Verifying Control Plane Link

Procedure

Step 3: In the main interface, select the tab BSC Information and click the button

Ater Connection Channel.

The Ater connection channel 0 is configured in the GEIUT board in slot 14 of the

GEPS subrack 0.

Page 35: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 35HUAWEI Confidential

Verifying Control Plane Link

Procedure

Step 4: Choose the menu BSC Maintenance > Maintain Transmission and

Signaling > Query MTP2 Link State.

Type 0 in Subrack NO., 14 in Slot NO., and 0 in Link NO. and then click the

button Query.

If Link Status is Service Subscribed, the MTP2 link is operational.

Page 36: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 36HUAWEI Confidential

Verifying Control Plane Link

Procedure

Step 5: Choose the menu BSC Maintenance > Maintain Transmission and

Signaling > Query MTP3 Link State .

Select subrack 0, slot 14, link 0, GXPUM 0, and CPU 0 and then click the button

Query.

If the link status is available, the MTP3 link is operational.

Page 37: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 37HUAWEI Confidential

Verifying Control Plane Link

Procedure

Step 6: Choose the menu BSC Maintenance > Maintain Transmission and

Signaling > Maintain SCCP .

Type 0 in DSP Index, select Query in Operation, and click the button Query.

If both DSP Status and SCCP Status are Allowed and Congestion Status is

Normal, the DSP status of the SCCP link is normal.

Page 38: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 38HUAWEI Confidential

Verifying Control Plane Link

Procedure

Step 7: In the tab page Subsystem Operation, type the subsystem index NO.,

select Query in Operation, and click the button Query. Query the status of

subsystems 0 to 3.

If Subsystem Status is all Normal, the SCCP link subsystem is operational. If

the MTP2, MTP3, and SCCP link status are all normal, the control plane link of

the A interface is operational.

Page 39: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 39HUAWEI Confidential

Verifying User Plane Channel

Purpose

To check whether the user plane

channel of the A interface is operational

when E1/T1 bears the A interface.

Procedure

Choose the menu BSC

Maintenance > Maintain User

Resource > Maintain A Interface

Circuit.

Select the GTCS subrack NO., type

the CIC number range, and click

Query.

If CIC status is Idle or Busy, the A

interface circuit channel is

operational.

Page 40: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 40HUAWEI Confidential

Verifying Pb Interface

Ensure the following conditions before

verifying the Pb interface:

The BSC commissioning is passed.

The transmission between the BSC and the

PCU is connected.

The PCU is operational.

The process of verifying the Pb interface is

shown on the right.

Verify physical link

Verify control plane link

Verify user plane link

Process alarms

Page 41: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 41HUAWEI Confidential

Verifying Physical Link

Purpose

To check whether the physical channel of the Pb interface is operational when E1/T1

bears the Pb interface.

Page 42: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 42HUAWEI Confidential

Verifying Physical Link

Procedure

Choose the menu BSC Maintenance > Maintain Transmission and Signaling >

Query Interface Board Port State .

In the displayed interface, select the subrack NO., slot NO., and port NO. for the

GEIUP board connected to the PCU.

If Port Status is Normal, the Pb interface physical link is operational.

Page 43: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 43HUAWEI Confidential

Verifying Control Plane Link

Purpose

To check whether the control plane link of the Pb interface is operational.

Procedure

Choose the menu BSC Maintenance > Maintain Transmission and Signaling >

Maintain LAPD Link .

Select PBSL under LAPD Link Range, select PCU from Candidate NE, and click

the Query button.

If PBSL link status is normal, the control plane link of the Pb interface is operational.

Page 44: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 44HUAWEI Confidential

Verifying User Plane Channel

Purpose

To check whether the user plane channel of the Pb interface is operational when

E1/T1 bears the Pb interface.

Page 45: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 45HUAWEI Confidential

Verifying User Plane Channel

Procedure

Choose the menuBSC Maintenance > Maintain User Resource > Maintain Pb

Interface Circuit .

In the displayed interface, select Pb interface position, and select the subrack NO.,

PCU NO., and CIC number range.

If CIC status is Not Installed, Idle, or Busy, the user plane channel of the Pb

interface is operational.

Page 46: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 46HUAWEI Confidential

Chapter 1 Overview of Commissioning

Chapter 2 Commissioning of Interface

Chapter 3 Service Verification

Page 47: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 47HUAWEI Confidential

Verifying Services

Ensure the following conditions before verifying services:

The BSC commissioning is passed.

The commissioning for the Abis, Ater, A, and Pb interfaces is passed.

The test MS is functional and already subscribed in the HLR.

Verification services comprise

Dialing test for basic services

Dialing test for feature services

Page 48: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Dialing Test for Basic Services

Purpose

To check whether the BSC6000 can provide basic services.

The basic services can be categorized into speech services, packet

services, and O&M management services.

Before verifying the basic services, start the related interface message

tracking on the LMT.

Page 49: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 49HUAWEI Confidential

Dialing Test for Basic Services

Basic Service

Procedure of Dialing Test Expected Result

Speech service

Use a test MS to dial a fixed-line phone for 50 times, and use the fixed-line phone to dial the test MS for 50 times.

The call proceeding success ratio is more than 90%.Speech is clear and no evident noise exists.

Use a test MS to dial another MS for 50 times.

The call proceeding success ratio is more than 90%.Speech is clear and no evident noise exists.

Data service

Use a test MS to send fax to the fax machine, and use the fax machine to send a fax to the MS.

The fax file is sent and received correctly.

Use a test MS to test GPRS or EDGE service functions.

The data rate is consistent with the test data rate obtained in the lab.

O&M management

While services are running, perform active/standby switchover 5 times for the boards GXPU, GSCU, GTNU, GPUC, GEIU, and GGCU.

The switchover success ratio is more than 90%. The running services are not affected.

Page 50: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Dialing Test for Feature Service

Purpose

To check whether the BSC6000 can provide License feature services.

Feature services vary according to offices. This presentation describes

inter-system handover service, location service, and AMR service.

Before verifying the feature services, start the related interface message

tracking on the LMT.

Page 51: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 51HUAWEI Confidential

Dialing Test for Feature Service

Feature Service

Procedure of Dialing Test Requirement

Inter-system handover service

Handover a dual-mode MS from the GSM network to the UMTS network for 50 times. Handover the dual-mode MS from the UMTS network to the GSM network for 50 times.

The call proceeding success ratio is more than 90%.Speech is clear and no evident noise exists.

Location service

Use a test MS to initiate a call. Locate the MS while the connection is in hold.

The MS position meets the precision requirements.

AMR service

Use a test MS to dial a fixed-line phone for 50 times. Select the speech version at AMR.

The call proceeding success ratio is more than 90%.Speech is clear and no evident noise exists.

Page 52: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 52HUAWEI Confidential

Connecting BSC6000 to M2000

Perform the following operations on the Telnet terminal of the

BSC6000:

Run the route command to query the configured route information.

The information about the route to the M2000 is displayed. The route

information is configured on the GBAM server.

If route information exists, the operation is completed.

If route information does not exist, run the route command.

Set Destination Network Address to M2000 Server IP Address, set

Destination Address Mask to M2000 Server IP Address Mask, and set

Forward Routing Address to Router IP Address.

Page 53: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd. Page 53HUAWEI Confidential

This presentation describes the following

information about the HUAWEI BSC6000: Commissioning preparations and

precautions System commissioning process Verification methods of interface data Service verification methods and steps

Page 54: 5. ene040613040006 huawei bsc6000 software commissioning 20061231-a-1.0

HUAWEI TECHNOLOGIES Co., Ltd.

www.huawei.com

HUAWEI Confidential

Internal Use (Only) Dec. 31 2006

GSM BSS Training Team

Thank You

www.huawei.com