5-29-14 Not Active Log RFI

6
PREPARE LOG SHEET OF REQUEST FOR INFORMATION Project WEST SUPER BLOCK Location 3rd cor 5th and 28th Avenue, West Crescent District, Fort Bonifacio !o"a!, #a$ui$ Cit% Date Released TITLE Reply Needed RESPONSE not active Please clarify the division 7 thermal moisture protection traffic coatin! part " clause "#$% & ' EL'STO(ERI) *RET+'NE TR',,I) TOPPIN- Provide at par.in! slots/drive0ays directly a1ove 0ater tan.s at 2asement "# In relative to the 0ater tan.s location at 23# 0hich 0ill !overn 23 or 2"4 Please clarify the division 7 thermal moisture protection traffic coatin! part " clause "#$% & ) EL'STO(ERI) *RET+'NE TR',,I) TOPPIN- Dry (il Thic.ness5 Ramps and turn&around areas5 Provide minimum 6$mils additional 0earin! coat 0ith a!!re!ate over medium duty coatin! for heavy duty usa!e8# 9indly clarify the as per schedule of finishes is "$$mm : "$$mm Non&s.id )oncrete Pavers and the 0ater proofin! as per cold fluid 0aterproofin! is included the ramp ;ehicular Ramps from 2asement % to 2asement "# )larify 0hich material to 1e used4

Transcript of 5-29-14 Not Active Log RFI

RFA log Sheet

LOG SHEET OF REQUEST FOR INFORMATION ProjectWEST SUPER BLOCKArchitecturalLocation3rd cor 5th and 28th Avenue, West Crescent District, Fort Bonifacio Global, Taguig City Date Released TITLEReply NeededRESPONSEACTIONS TO BE TAKENnot activePlease clarify the division 7 thermal moisture protection, traffic coating part 2 clause 2.01 - A ELASTOMERIC URETHANE TRAFFIC TOPPING Provide at parking slots/driveways directly above water tanks at Basement 2. In relative to the water tanks location at B6. which will govern B6 or B2?Please clarify the division 7 thermal moisture protection, traffic coating part 2 clause 2.01 - C ELASTOMERIC URETHANE TRAFFIC TOPPING Dry Mil Thickness: Ramps and turn-around areas: Provide minimum 30mils additional wearing coat with aggregate over medium duty coating (for heavy duty usage). Kindly clarify the as per schedule of finishes is 200mm x 200mm Non-skid Concrete Pavers and the water proofing as per cold fluid waterproofing is included the ramp Vehicular Ramps from Basement 1 to Basement 2. Clarify which material to be used?

LOG SHEET OF REQUEST FOR APPROVAL ProjectWEST SUPER BLOCKArchitecturalLocation3rd cor 5th and 28th Avenue, West Crescent District, Fort Bonifacio Global, Taguig City Date Released TITLEReply NeededRESPONSEACTIONS TO BE TAKEN

LOG SHEET OF REQUEST FOR APPROVAL ProjectWEST SUPER BLOCKArchitecturalLocation3rd cor 5th and 28th Avenue, West Crescent District, Fort Bonifacio Global, Taguig City Date Released TITLEReply NeededRESPONSEACTIONS TO BE TAKEN

PREPARED BY JCE

Sheet5