Page 1: 4. Do not scale drawings. · 4. Do not scale drawings. 5. Subject to change without notice. 6. For patent information, visit ourPatent Page. 4 3/16" 106.76mm 1 11/16" 42.25mm 3 1/2"

Document Date: 7.14.2020

Page 2: 4. Do not scale drawings. · 4. Do not scale drawings. 5. Subject to change without notice. 6. For patent information, visit ourPatent Page. 4 3/16" 106.76mm 1 11/16" 42.25mm 3 1/2"

Installation to be completed in accordance with manufacturer's written specifications and installation instructions.1.See spec sheet or contact manufacturer for detailed material, finishes, and configuration options.2.Contact manufacturer for detailed layout.3.Do not scale drawings.4.Subject to change without notice.5.For patent information, visit our6. Patent Page.

4 3/16"106.76mm

1 11/16"42.25mm

3 1/2"88.90mm

2 3/8"60.96mm

1:5

Cut Sheet - ASG MEMBRANE-E65

4/24/2018Scale:

289 Harrel StreetMorrisville, VT 05661

Phone: 1.888.766.4273Fax: 1.888.766.9994

Email: [email protected]

Alpine SafeGuard

Page 3: 4. Do not scale drawings. · 4. Do not scale drawings. 5. Subject to change without notice. 6. For patent information, visit ourPatent Page. 4 3/16" 106.76mm 1 11/16" 42.25mm 3 1/2"

Installation to be completed in accordance with manufacturer's written specifications and installation instructions.1.See spec sheet or contact manufacturer for detailed material, finishes, and configuration options.2.Contact manufacturer for detailed layout.3.Do not scale drawings.4.Subject to change without notice.5.For patent information, visit our6. Patent Page.

1

3

8 7

5

6

2

4

9

ITEM NO. PART CODE DESCRIPTION QTY

1 ASG UNIVERSAL-BRKT ALPINE SAFEGUARD BRACKET-BLK 1

2 BASE SS 6X5.5 SS 6X5.5 BASE PLATE 1

3 W-NEO SS-.313 SS NEO WASHER .313 ID (INCLUDED IN POLY KIT 6X5.5 BASE) 2

4 N-HX SS-.3125-18 NUT SS HEX FINISHED .3125-18 (INCLUDED IN POLY KIT 6X5.5 BASE) 2

5 ASG UNIVERSAL-CLIP ALPINE SAFEGUARD CLIP-.375 1

6 B-HX SS-.375-16X1.25 SS HEX BOLT .375-16X1.25 (INCLUDED IN POLY KIT PP202) 1

7 N-FL SS-.375-16 SS FLANGE NUT .375-16 (INCLUDED IN POLY KIT PP202) 1

8 ALPINE SIMGUARD-BAR ALPINE SIMPLEGUARD BAR-AL AS NEEDED

9 TARGET PATCH FLASHING TARGET PATCH FLASHING (CUSTOMER SUPPLIED) 1

1:6

289 Harrel StreetMorrisville, VT 05661

Phone: 1.888.766.4273Fax: 1.888.766.9994

Email: [email protected]

Alpine SafeGuard

4/08/2019Scale:

Assembly Sheet - ASG MEMBRANE-E65

Lorna.Gaylor
Highlight
Lorna.Gaylor
Highlight
Lorna.Gaylor
Highlight
Lorna.Gaylor
Highlight
Page 4: 4. Do not scale drawings. · 4. Do not scale drawings. 5. Subject to change without notice. 6. For patent information, visit ourPatent Page. 4 3/16" 106.76mm 1 11/16" 42.25mm 3 1/2"

289 Harrel Street, Morrisville, VT 05661 • Toll Free Phone 1.888.766.4273 • Toll Free Fax 1.888.766.9994 [email protected] A Division of Vermont Slate & Copper Services, Inc.

Alpine SafeGuard ASG MEMBRANE-E65 Specification Sheet

PART 1 – GENERAL

1.1 SUMMARY

A. WORK INCLUDES1. ASG MEMBRANE-E65 snow guard that attaches directly to the roof deck.2. Coordinate with the installation of the roof to assure proper placement of the

snow guards.3. Provide appropriate fasteners for the roof system.

B. RELATED SECTIONS1. Section 076000: Flashing and Sheet Metal MasterFormat 2016 07 60 002. Section 075000: Membrane Roofing MasterFormat 2016 07 50 00 3. Section 077253: Snow Guards MasterFormat 2016 07 72 53

1.2 SYSTEM DESCRIPTION

A. COMPONENTS:

Bracket: A black anodized aluminum bracket with two countersunk holes to accept the 5/16” base plate studs and a T-Slot to accept the 5/16” stainless steel hex bolt and flange nut. 1. ASG UNIVERSAL-BRKT

Base: A stainless steel base plate with two 5/16”-18 x ¾” stainless steel flat head bolts welded into countersinks. 2. BASE SS 6X5.53. W-NEO SS-.3134. N-HX SS-.3125-18

Clip: An aluminum clip that attaches to the top of the clamp and hooks onto the back of the bar. 5. ASG UNIVERSAL-CLIP6. B-HX SS-.375-16X1.257. N-FL SS-.375-16

Bar: An aluminum bar (includes splice) that attaches to the mounting clamp. Color insert strip and ice flags are optional. 8. ALPINE SIMGUARD-BAR

Page 5: 4. Do not scale drawings. · 4. Do not scale drawings. 5. Subject to change without notice. 6. For patent information, visit ourPatent Page. 4 3/16" 106.76mm 1 11/16" 42.25mm 3 1/2"

289 Harrel Street, Morrisville, VT 05661 • Toll Free Phone 1.888.766.4273 • Toll Free Fax 1.888.766.9994 [email protected] A Division of Vermont Slate & Copper Services, Inc.

Flashing: An appropriate size, material, and method of installation to meet roof manufacturer’s requirements. 9. TARGET PATCH FLASHING (CUSTOMER SUPPLIED)

B. DESIGN REQUIREMENTS:1. Spacing to be recommended by manufacturer or building engineer.2. Install a minimum of 8 fasteners per snow guard.3. It is important to design new structures or assess existing structures to make

sure that they can withstand retained snow loads.

1.3 SUBMITTAL

A. Submit manufacturer's specifications, standard detail drawings, installationinstructions, and recommended layout.

1.4 QUALITY ASSURANCE

A. Installer to be experienced in the installation of specified roofing material and snowguards for not less than 5 years in the area of the project.

1.5 DELIVERY / STORAGE / HANDLING

A. Inspect material upon delivery and order replacements for any missing or defectiveitems. Keep material dry, covered and off the ground until installed.

PART 2 – PRODUCTS

2.1 MANUFACTURER

A. Alpine SnowGuards. A division of Vermont Slate & Copper Services Inc.289 Harrel St. Morrisville, VT 05661, (888) 766-4273www.alpinesnowguards.com.

2.2 MATERIALS

1. ASG UNIVERSAL-BRKT – 6000 Series Aluminum

2. BASE SS 6X5.5 – 11 Gauge 304 Stainless Steel

Page 6: 4. Do not scale drawings. · 4. Do not scale drawings. 5. Subject to change without notice. 6. For patent information, visit ourPatent Page. 4 3/16" 106.76mm 1 11/16" 42.25mm 3 1/2"

289 Harrel Street, Morrisville, VT 05661 • Toll Free Phone 1.888.766.4273 • Toll Free Fax 1.888.766.9994 [email protected] A Division of Vermont Slate & Copper Services, Inc.

3. W-NEO SS-.313 – 304 Stainless Steel and EPDM

4. N-HX SS-.3125-18 – 304 Stainless Steel

5. ASG UNIVERSAL-CLIP – 6000 Series Aluminum

6. B-HX SS-.375-16X1.25 – 304 Stainless Steel

7. N-FL SS-.375-16 – 304 Stainless Steel

8. ALPINE SIMGUARD-BAR – 6000 Series Aluminum

9. TARGET PATCH FLASHING (CUSTOMER SUPPLIED)

2.3 FINISH (choose one):

A. Mill Finish – standard (ASG UNIVERSAL-BRKT Only - Black Anodized)B. Powder Coated – Available at additional cost

PART 3 – EXECUTION

3.1 EXAMINATION

A. Substrate1. Inspect structure on which the brackets are to be installed and verify that it

will withstand any additional loading that it may incur. Notify generalcontractor of any deficiencies before installing Alpine SnowGuards.

2. Verify that roofing material has been installed correctly prior to installing snowguards.

3.2 INSTALLATION

A. Comply with architectural drawings and snow guard manufacturer’srecommendations for location of system. Comply with manufacturer's writteninstallation instructions for installation and layout.

Document Version 04.08.2019 07 72 53 Snow Guards

Page 7: 4. Do not scale drawings. · 4. Do not scale drawings. 5. Subject to change without notice. 6. For patent information, visit ourPatent Page. 4 3/16" 106.76mm 1 11/16" 42.25mm 3 1/2"

289 Harrel Street, Morrisville, VT 05661 • Toll Free Phone 1.888.766.4273 • Toll Free Fax 1.888.766.9994 • [email protected] A Division of Vermont Slate & Copper Services, Inc.

ASG MEMBRANE-E65 Snow Guard Installation Instructions

New or existing membrane (EPDM, TPO, PVC)

Installation:

5.

6.

Hook the clip onto the bar, slide the bolt forward and tighten the flange nut (fig. D).Join sections of bar by sliding the splice into the ends of the abutting bars. Note: Do not installruns of bar more than 100 feet long without a break to allow for thermal expansion. Bar cannotextend past the last bracket more than 6"-8".Optional: Install Ice Flags by hooking them onto the bar and securing with a TEK screw.NOTE: Once the point of the TEK screw is through the metal, only tighten enough to engagethe TEK screw. Do not over-tighten or over-torque with a drill. Tighten by hand only to securelyengage the flag. A color insert strip is also available, to match the color of the roofing, and is slidinto the front groove on the bar.

Document Version 04.02.2019 07 72 53 Snow Guards

1. Beginning 12"-18" above the exterior load bearing wall, install 8appropriate fasteners through the base plateand into the roof decking (fig. A).

2. Once the base plates have been installed, apply an appropriatecustomer-supplied target patch flashing.

3. Using the supplied nuts and washers, install the bracket on top of the 2base plate studs (fig. B).

4. Slide the bolt, clip and flange nut into the T-slot on top of the bracket,and place the bar on the bracket (fig. C)

7.

Alpine SafeGuard

Typical Roof Types:

Page 8: 4. Do not scale drawings. · 4. Do not scale drawings. 5. Subject to change without notice. 6. For patent information, visit ourPatent Page. 4 3/16" 106.76mm 1 11/16" 42.25mm 3 1/2"

289 Harrel Street Morrisville, VT 05661

Toll Free Phone 1.888.766.4273 Toll Free Fax 1.888.766.9994 [email protected]

Snow Guard Maintenance

© Copyright 2020, Alpine SnowGuards®A division of Vermont Slate & Copper Services, Inc.

Document version 06.24.2020

Snow Guard Maintenance

All snow guards should be checked as part of a yearly roof inspection by an experienced roofing and snow guard inspector. Any defects in materials and workmanship should be reported to the manufacturer immediately.

Refer to the categories below for additional inspection information. Alpine SnowGuards will not be responsible for any snow guard system that has not been properly maintained.

Pad Style SnowGuards – fastened using mechanical fasteners • Inspect each unit to ensure snow guard assembly is intact.• Inspect fasteners into the roof deck wherever possible.

Pad Style SnowGuards – adhesive mounted • Inspect each unit to ensure snow guard assembly is intact.• Inspect sealant around the perimeter. Remove and reapply any areas that are no longer watertight.• Inspect units for slippage or peeling of the tape.• Remove and reinstall these units.

Pipe Style – fastened to roof deck • Inspect each unit to ensure snow guard assembly is intact.• Inspect all fasteners in to the roof deck wherever possible. Inspect any snow guard related

waterproofing and replace or repair where necessary to ensure roof integrity.• If any tubing has bent or shows any other evidence of failure or damage, contact the manufacturer

immediately.

Pipe Style – clamped to standing seam • Inspect each unit to ensure snow guard assembly is intact.• Inspect and check each set screw with a torque wrench to ensure proper fastening has been maintained.• If any tubing has bent or shows any other evidence of failure or damage, contact the manufacturer

immediately.