IntroductionGEA Searle offers an expanded range of CO2 unit

coolers for commercial and retail refrigeration

applications. The coolers have been optimised to

meet the diverse requirements of the developing

CO2 system designs; variables include transcriti-

cal, subcritical and standing pressures. GEA Searle

have designed a “one size fts all” specifcation toapply to our most popular ranges.

GeneralThe cooler ranges detailed within this brochure are

hybrid versions of our tried and tested TG, KEC,

KME and DSR coolers. Whilst the coil technology

employed is different the overall dimensions and

electrical loadings remain as per our standard (non

CO2) ranges.

CoilsMaximum operating pressure 75BarG with

aluminium fns as standard. Other fn materials

and coatings are available upon request. Flow

direction arrows added to connections to reduce

on site confusion with the smaller pipe sizes and

single circuit (non distributor) coils.

CaseworkWhite powder coated pre-galvanised sheet steel.

DefrostOption for electric coil and tray.

 Quality AssuranceSearle is a quality assured under the BSEN ISO

9001 encompassing Performance Testing, Manu-facturing Systems and Inspection Procedures. The

coolers are covered by Searle’s full technical sup-

port and 24 months warranty.

CE Marking and PEDSearle’s coolers are CE marked under the ‘Low

Voltage Directive’. Under the ‘Pressure Equip-

ment Directive’, all are category 1 or ‘SEP’ and

therefore excluded from it.

 

WebsiteKeep up to date with our products and latest news

by visiting the website www.searle.co.uk

 

Check product availability - our unique website

allows visitors to use an interactive product selec-

tor showing the latest stock availability.

Download brochure and technical documents -

visitors can view and download the latest informa-

tion from the website, including installation and

maintenance instructions.

General InformationIntroductionGEA Searle offre une large gamme d’évaporateurs

CO2 pour les applications commerciales et semi

–industrielles.Les évaporateurs ont été optimisés

pour répondre aux exigences des systèmes CO2 ;

les variables comprennent les pressions trans-cri-

tiques, sub-critiques et à l’arrêt. GEA Searle a con-

çu une spécifcation « tout en un »pour s’appliquerà nos gammes les plus courrantes.

GénéralitéLes évaporateurs détaillés dans la présente

brochure sont des versions hybrides de nos évapo-

rateurs testés et approuvés TG,KEC,KMe et DSR.

Bien que la technologie employée pour la batte-

rie soit différente, les dimensions hors tout et les

équipements électriques restent selon pour nos

gammes standards (non CO2)

BatterieLa pression maximale de service est de 75 BarG

avec les ailettes aluminium en standard. Les

autres matériaux et protections sont disponibles

sur demande. Pour réduire les confusions sur site

pour les petites batteries à petits tubes et un seul

circuit sans distributeur le sens de circulation du

uide est marqué par des èches sur les connec-

tions.

CarrosserieTôle d’acier galvanise recouverte de peinture

blanche cuite au four

Dégivrage

Dégivrage électrique bac et batterie en option. Assurance qualitéSearle est certifé BSEN ISO 9001 comprenant les

tests de performance ,les systèmes de fabrication

et les procédures de contrôle .Les évaporateurs

sont couverts d’une assistance technique et d’une

garantie de 24 mois.

Marquage CE et DESPLes évaporateurs Searle sont marqués CE selon la

“directive basse tension”. Répondant à la directive

des équipement sous pression sous la catégorie 1

ou SEP ,ils en sont exclus.

 Site internetRestez informés des produits et nouveautés en

visitant le site internet www.searle.co.uk

 

Contrôler la disponibilité d’un produit-Notre

site internet autorise le visiteur à sélectionner un

produit et vérifer sa disponibilité

Téléchargement de brochures commerciales

et documents techniques. Le visiteurs peut voir et

télécharger les dernières informations sur notre

site comme les guides d’installation et de mainte-

nance

 

EinführungGEA Searle bietet ein umfassendes Sortiment von

CO2-Aggregat-Kühlern für großtechnische und

Einzelhandelsanwendungen an. Die Kühler sind opti-

mal so ausgelegt, dass sie die unterschiedlichen An-

forderungen der neuen CO2-Systemkonstruktionen

erfüllen; zu den Variablen gehören transkritischer,

unterkritischer und Standdruck . GEA Searle hat eine„one-size-fts-all“ Spezifkation entwickelt, die sich

auf alle unserer beliebtesten Baureihen anwenden

lässt.

AllgemeinesBei den in dieser Broschüre beschriebenen Kühlern

handelt es sich um Hybridmodelle unserer erprob-

ten und bewährten KME und DSR Kühler. Während

die eingesetzte Rohrtechnik anders ist, entsprechen

Gesamtabmessungen und Strombelastungen weiter-

hin unseren standardmäßigen (nicht CO2) Baureihen.

Die KuehlschlangenMaximaler Betriebsdruck ist 75BarG mit Alumini-

umlamellen als Standard. Andere Lamellenmaterialien

und Beschichtungen sind auf Anfrage erhaeltlich.

Flussrichtungspfeile sind zu den Verbindungen

hinzugefuegt um Verwechslungen vor Ort mit den

kleineren Rohrgroessen und den einzelgeschalteten

(nicht verteilbaren) Kuehlschlangen auszuschliessen.

GehäuseWeißbeschichtetes verzinktes Stahlblech.

AbtauenOption für Elektrorohr und Tray.

QualitätssicherungSearle ist gemäß der Norm BSEN ISO 9001 qualitäts-

gesichert, einschließlich Eignungsprüfung, Herstel-

lungssystem und Inspektionsverfahren. Die KEC, Kme

und DSR Kühler werden mit Searles kompletten tech-

nischen Kundendienstleistungen und einer einjähri-

gen Garantie geliefert.

CE-Marken und PEDSearles Kühler sind für die „Niederspannungsrichtlinie

„ CE-markiert. Unter der Druckgeräterichtlinie sind

alle in Kategorie 1 oder SEP und daher von dieser Rich-

tlinie ausgeschlossen.

WebsiteDas Neuste über unsere Produkte und andere Neuig-

keiten erfahren Sie auf unserer Website www.searle.

co.uk

 

Verfügbarkeit unserer Produkte – auf unserer

einzigartigen Website können Besucher mit Hilfe eines

interaktiven Produktselektors genau den letzten Ver-

fügbarkeitsstand überprüfen.

Herunterladen von Broschüre und technischen

Unterlagen – Besucher der Website könnenhier die

neuesten Informationen einschließlich Installations-und Wartungsanleiten lesen und herunterladen.

 

Page 3: 4 - 1001 CO2 Cooler Brochure English 273-103-048 (SEARLE)

7/31/2019 4 - 1001 CO2 Cooler Brochure English 273-103-048 (SEARLE)

http://slidepdf.com/reader/full/4-1001-co2-cooler-brochure-english-273-103-048-searle 3/8

5KDT1

6KDT1

7KDT1

8KDT1

9KDT1

10 KDT1

11 KDT1

12K DT1

*

3

General Information

1 10 100

Capacity kW @ 8 kTDOptions

   M  o   d  e   l  s

KEC

KMC

DSC

TGC

   N  o   f  a  n  s

1 - 3

1 - 4

1 - 4

1 - 3

   E   C   F  a  n  s

   S   t  a  n   d  a  r   d

   E   l  e  c   t  r   i  c   D  e   f  r  o  s   t

Kit

   S  u  p  p   l  y

1 ph

1 &

3ph

1 ph

1 ph

       C     o     n       f     g     u     r     a      t       i     o     n

1.2 - 10.7

5.8 - 28

0.8 - 15

0.5- 3.4

General Notes:

1 Capacities shown at SC2 conditions i.e. 8K td, -8ºCevpaoration temperature

2 Air throws based upon terminal velocity of 0.25m/s.

3 Fan power is total fan power for the unit.

4 HS - High speed, LS - Low speed

5 Noise levels quoted @3m 45º directivity within free

feld conditions

6 designates units which have a low circuit loading.

Refer to your supplier for selections below -15°Cevaporating temperature.

Designation

Factors apply to all CO2 Coolers

Evaporating Temperature oC

Correction Factors: 

Multiply capacity by appropriate correction factor to give per-formance at chosen conditions

   C  o  r  r  e  c   t   i  o  n   F  a  c   t  o  r   (  m  u   l   t   i  p   l   i  e  r   )

KE C X 30 L Range KE, KM, DS, TG

CO2 C

Type X = Direct Expansion, P = Pump Circulation

Model Various

Defrost Blank = No Defrost, L = Electric

Page 4: 4 - 1001 CO2 Cooler Brochure English 273-103-048 (SEARLE)

7/31/2019 4 - 1001 CO2 Cooler Brochure English 273-103-048 (SEARLE)

http://slidepdf.com/reader/full/4-1001-co2-cooler-brochure-english-273-103-048-searle 4/8

Page 5: 4 - 1001 CO2 Cooler Brochure English 273-103-048 (SEARLE)

7/31/2019 4 - 1001 CO2 Cooler Brochure English 273-103-048 (SEARLE)

http://slidepdf.com/reader/full/4-1001-co2-cooler-brochure-english-273-103-048-searle 5/85

KMC Evaporator Range

Model

K M C X 5 0

K M C X 6 0

K M C X 1 4 0

K M C X 1 1 5

K M C X 9 5

K M C X 8 0

K M C X 1 7 5

Direct expansion - CX

Pump cirulation - CP

Capacity

kW

Air Vol.

m3 /s

Surface

m2

Int. Vol.

dm3 

Weight

AL - kg inlet outlet

Conn SizeAir Throw

m

6.36

7.6510.08

12.92

15.12

19.53

24.57

0.89

0.961.89

1.78

2.83

2.68

3.45

18.26

27.0524.35

36.52

36.52

54.78

64.92

6

98

11

11

17

19

85

112129

139

170

195

217

1/2”

1/2”1/2”

1/2”

1/2”

5/8”

5/8”

5/8”

5/8”5/8”

5/8”

5/8”

7/8”

7/8”

17

1919

17

19

17

17

Model Length

mm

Height

mm

Width

mm

1007

1332

1682

1682

2357

2357

2732

575

575

575

575

575

575

575

536

536

536

536

536

536

536

Dimensions

Model

K M C P 5 0

K M C P 6 0

K M C P 1 4 0

K M C P 1 1 5

K M C P 9 5

K M C P 8 0

K M C P 1 7 5

Capacity

kW

Air Vol.

m3 /s

Surface

m2

Int. Vol.

dm3 

Weight

AL - kg inlet outlet

Conn SizeAir Throw

m

7.40

8.65

12.02

14.92

18.03

22.49

28.38

0.89

0.96

1.89

1.78

2.83

2.68

3.45

18.26

27.05

24.35

36.52

36.52

54.78

64.92

6

9

8

12

11

17

20

85

112

129

139

170

195

217

5/8”

5/8”

5/8”

7/8”

7/8”

7/8”

7/8”

7/8”

7/8”

7/8”

1 1/8”

1 1/8”

1 1/8”

1 1/8”

17

19

19

17

19

17

17

Model

K M C * 5 0

K M C * 6 0

K M C * 1 4 0

K M C * 1 1 5

K M C * 9 5

K M C * 8 0

K M C * 1 7 5

400V - 3ph - 50Hz

1

1

2

2

3

3

4

400

400

400

400

400

400

400

190

190

380

380

570

570

760

1.05

1.05

1.05

1.05

1.05

1.05

1.05

4.5

4.5

4.5

4.5

4.5

4.5

4.5

0.65

0.65

0.65

0.65

0.65

0.65

0.65

60

60

63

63

65

65

66

QtyDiamm

Speedrpm

PowerW SC

AFLCA

SCA

FLCA

230V - 1ph - 50Hz

Fan Detail

2.75

2.75

2.75

2.75

2.75

2.75

2.75

K M C * 5 0

K M C * 6 0

K M C * 1 4 0

K M C * 1 1 5

K M C * 9 5

K M C * 8 0

K M C * 1 7 5

1410

1410

1410

1410

1410

1410

1410

Noise

dB(A)@3m

Fan & Noise Data

Dimensions Defrost Data

1.59

2.40

3.18

3.18

4.80

4.80

5.64

0.80

1.20

1.59

1.59

2.40

2.40

2.82

Defrost

CoilkW

TraykW

H

LW

Note: See general notes on page 3

Note: Power per unit currents per motor

Page 6: 4 - 1001 CO2 Cooler Brochure English 273-103-048 (SEARLE)

7/31/2019 4 - 1001 CO2 Cooler Brochure English 273-103-048 (SEARLE)

http://slidepdf.com/reader/full/4-1001-co2-cooler-brochure-english-273-103-048-searle 6/8Note: See general notes on page 3

D S C X 1 1 6

6

DSC Evaporator RangeDirect expansion - CX

Model

D S C X 1 2

D S C X 1 9

D S C X 5 1

D S C X 4 2

D S C X 3 6D S C X 2 2

D S C X 6 2

D S C X 8 3

D S C X 6 8

D S C X 1 0 0

Capacity Surface

m2 

Weight

AL - kg inlet outlet

Conn Size Air Throw

0.94

1.92

2.473.60

4.77

5.80

7.62

7.02

11.17

9.61

13.06

0.68

1.21

1.522.31

2.95

3.78

5.16

4.61

7.51

6.00

8.64

0.32

0.31

0.300.61

0.59

0.92

1.22

0.88

1.72

1.18

1.56

2

3

34

6

5

7

8

11

10

16

52

56

5979

85

104

132

113

155

144

172

3/8”

3/8”

3/8”1/2”

1/2”

1/2”

1/2”

1/2”

1/2”

1/2”

1/2”

5/8”

5/8”

5/8”5/8”

5/8”

5/8”

5/8”

5/8”

5/8”

5/8”

5/8”

11

11

1112

11

12

12

11

11

11

11

HS - kW LS - kW

Air Vol

2.98

5.95

8.9310.82

16.23

16.23

21.64

24.35

36.07

32.46

54.10

HS - m3 /s LS - m3 /s

Int. Vol

dm3 HS - m LS - m

0.18

0.17

0.160.34

0.32

0.50

0.67

0.49

0.98

0.65

0.89

7

7

78

7

8

8

7

7

7

7

Pump cirulation - CP

D S C P 1 1 6

Model

D S C P 1 2

D S C P 1 9

D S C P 5 1

D S C P 4 2

D S C P 3 6

D S C P 2 2

D S C P 6 2

D S C P 8 3

D S C P 6 8

D S C P 1 0 0

Capacity Surface

m2 

Weight

AL - kg inlet outlet

Conn Size Air Throw

0.32

0.31

0.30

0.61

0.59

0.92

1.22

0.88

1.72

1.18

1.56

2

3

3

4

6

5

7

8

11

10

16

52

56

59

79

85

104

132

113

155

144

172

3/8”

3/8”

3/8”

5/8”

5/8”

5/8”

5/8”

5/8”

5/8”

5/8”

5/8”

5/8”

5/8”

5/8”

7/8”

7/8”

7/8”

7/8”

7/8”

7/8”

7/8”

7/8”

11

11

11

12

11

12

12

11

11

11

11

HS - kW LS - kW

Air Vol

2.98

5.95

8.93

10.82

16.23

16.23

21.64

24.35

36.07

32.46

54.10

HS - m3 /s LS - m3 /s

Int. Vol

dm3 HS - m LS - m

0.18

0.17

0.16

0.34

0.32

0.50

0.67

0.49

0.98

0.65

0.89

7

7

7

8

7

8

8

7

7

7

7

ModelLS - Low Speed

QtyDiamm

Speedrpm

 HS/LS

PowerW

SCA

FLCA

SCA

FLCA

HS - High Speed

Fan Detail

D S C * 1 1 6

D S C * 1 2

D S C * 1 9

D S C * 5 1

D S C * 4 2

D S C * 3 6

D S C * 2 2

D S C * 6 2

D S C * 8 3

D S C * 6 8

D S C * 1 0 0

Model Length

mm

Height

mm

Width

mm

Dimensions

D S C * 1 1 6

D S C * 1 2D S C * 1 9

D S C * 5 1D S C * 4 2

D S C * 3 6

D S C * 2 2

D S C * 6 2

D S C * 8 3D S C * 6 8

D S C * 1 0 0

PowerW

1

1

1

2

2

3

3

4

4

4

4

305

305

305

305

305

305

305

305

305

305

305

1300/750

1300/750

1300/750

1300/750

1300/750

1300/750

1300/750

1300/750

1300/750

1400/800

1400/800

64

64

64

128

128

192

192

256

256

640

640

0.30

0.30

0.30

0.30

0.30

0.30

0.30

0.30

0.30

0.81

0.81

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.4

1.9

1.9

26

26

26

52

52

78

78

104

104

376

376

0.14

0.14

0.14

0.14

0.14

0.14

0.14

0.14

0.14

0.87

0.87

0.14

0.14

0.14

0.14

0.14

0.14

0.14

0.14

0.14

1.98

1.98

49

49

49

51

51

54

54

55

55

60

60

34

34

34

37

37

39

39

40

40

48

48

870870

870

1320

13201820

2320

1820

23202320

2320

266266

266

266

266266

266

266

266351

351

910910

910

910

910910

910

910

910910

910

1.18

2.26

2.78

4.31

5.38

6.74

8.92

8.02

12.87

10.81

14.74

0.83

1.41

1.66

2.71

3.23

4.25

5.78

5.03

8.41

6.57

9.34

Noise

dB(A)@3m

dB(A)@3m

Fan & Noise Data

Dimensions Defrost Data

0.000.000.00

0.000.002.00

2.00

0.00

0.000.000.00

1.58

5.705.705.67

5.67

1.58

1.582.85

2.854.27

4.27

Defrost

Coil

kW

Tray

kW

H

LW

Note: Power per unit currents per motor

Page 7: 4 - 1001 CO2 Cooler Brochure English 273-103-048 (SEARLE)

7/31/2019 4 - 1001 CO2 Cooler Brochure English 273-103-048 (SEARLE)

http://slidepdf.com/reader/full/4-1001-co2-cooler-brochure-english-273-103-048-searle 7/8Note: See general notes on page 3

7

TGC Evaporator Range

Model

T G C X 1

T G C X 2

T G C X 5

T G C X 4

T G C X 3 . 5T G C X 3

T G C X 6

Direct expansion - CX

T G C X 8

T G C X 7

Capacity

kW

Air Vol.

m3 /s

Surface

m2

Int. Vol.

dm3 

Weight

AL - kg inlet outlet

Conn SizeAir Throw

m

0.34

0.66

0.841.00

1.37

1.81

2.86

2.22

3.30

0.16

0.14

0.160.17

0.28

0.31

0.47

0.34

0.50

1.07

2.13

3.023.99

3.99

5.36

7.57

7.14

10.10

1

1

22

2

2

3

3

4

7

8

1012

14

16

24

19

27

3/8”

3/8”

3/8”3/8”

3/8”

3/8”

3/8”

3/8”

3/8”

5/8”

5/8”

5/8”5/8”

5/8”

5/8”

5/8”

5/8”

5/8”

4

4

44

4

5

5

5

5

Model Length

mm

Height

mm

Width

mm

525

525

690

865865

1120

1530

1120

1530

180

180

180

180180

180

180

230

230

375

375

375

375375

375

375

375

375

Dimensions

H

Model

1

1

1

1

2

2

3

2

3

230

230

230

230

230

230

230

230

230

1400

1400

1400

1400

1400

1400

1400

1400

1400

62

62

62

62

124

124

186

124

186

0.48

0.48

0.48

0.48

0.48

0.48

0.48

0.48

0.48

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

57

55

56

56

59

57

60

55

58

Pump cirulation - CP

Model

T G C P 1

T G C P 2

T G C P 5

T G C P 4

T G C P 3 . 5

T G C P 3

T G C P 6

T G C P 8

T G C P 7

Capacity

kW

Air Vol.

m3 /s

Surface

m2

Int. Vol.

dm3 

Weight

AL - kg inlet outlet

Conn SizeAir Throw

m

0.50

0.84

1.02

1.19

1.75

2.17

3.35

2.56

3.82

0.16

0.14

0.16

0.17

0.28

0.31

0.47

0.34

0.50

1.07

2.13

3.02

3.99

3.99

5.36

7.57

7.14

10.10

1

1

2

2

2

2

3

3

4

7

8

10

12

14

16

24

19

27

3/8”

3/8”

3/8”

3/8”

3/8”

3/8”

3/8”

3/8”

3/8”

5/8”

5/8”

5/8”

5/8”

5/8”

5/8”

5/8”

5/8”

5/8”

4

4

4

4

4

5

5

5

5

T G C * 1

T G C * 2

T G C * 5

T G C * 4

T G C * 3 . 5

T G C * 3

T G C * 6

T G C * 8

T G C * 7

T G C * 1

T G C * 2

T G C * 5

T G C * 4T G C * 3 . 5

T G C * 3

T G C * 6

T G C * 8

T G C * 7

QtyDiamm

Speedrpm

PowerW

NoiseFan Detail

dB(A)@3m

SCA

FLCA

Fan & Noise Data

Dimensions Defrost Data

275

550

700

900900

1000

1400

1000

1400

Defrost

Coil

kW

Tray

kW

2 x 250

2 x 250

2 x 325

2 x 4252 x 425

2 x 575

2 x 1030

2 x 675

2 x 1030

W

L

Note: Power per unit currents per motor

Page 8: 4 - 1001 CO2 Cooler Brochure English 273-103-048 (SEARLE)

7/31/2019 4 - 1001 CO2 Cooler Brochure English 273-103-048 (SEARLE)

http://slidepdf.com/reader/full/4-1001-co2-cooler-brochure-english-273-103-048-searle 8/8

We reserve the right to change in whole or part, the specifcation detailed in this brochure without prior notice and, when necessary to achieve continuous production, to use alternative

competitive designs of sub contract components made by various manufacturers.

  Issue No. CO2 Coolers Jan 010 Part No. 273-103-048

GEA Heat Exchangers

GEA Searle Ltd20 Davis Way, Newgate Lane, Fareham, PO14 1AR

Tel. +44 (0) 1329 823344, Fax +44 (0) 1329 821242

[email protected], www.searle.co.uk