3733 N WILLIAMS - portlandoregon.gov
Transcript of 3733 N WILLIAMS - portlandoregon.gov
HW
M OCCUPANCY FILED UNDER SEPARATE PERMIT
709 SF
12
M
RETAIL
1 / 60 GROSS
394 SF
2
R-2
APARTMENT
1 / 200 GROSS
42 SF
1
S-1
WATER RISER
1 / 300 GROSS
383 SF
2
R-2
APARTMENT
1 / 200 GROSS
20 SF
1
S-1
MECH
1 / 300 GROSS
54 SF
4
R-2
LOBBY
1 / 15 NET
89 SF
1
S-1
ELECTRICAL
1 / 300 GROSS
278 SF
1
S-1
TRASH
1 / 300 GROSS
310 SF
2
R-2
APARTMENT
1 / 200 GROSS
49 SF
1
S-1
STORAGE
1 / 300 GROSS
DIA
GO
NAL
DIS
TANCE =
63' -
0"
MIN
IMUM
EXIT
SEPERATI
ON D
ISTA
NCE =
21' -
0"
DIAG
ONAL D
ISTANCE = 58' - 0"
MIN
IMUM
EXIT SEPERATIO
N D
ISTANCE = 19' - 4"
EXIT ACCESS
EX
IT A
CC
ES
S
STEEL ACCESS GATE WITH PANIC HARDWARE
1 HR RATED EXTERIOR WALL, RATED FOR EXPOSURE FROM BOTH SIDES, PER TABLE 602 AND SECTION 705.5. TYP AT WALLS WITHIN 10' OF PROPERTY LINE
G0.21
2
3
G0.22
4
G0.22
5
G0.22
G0.21
4
G0.21
5
EAST BUILDINGWEST BUILDING
11 418 SF
28
R-2
COURTYARD
1 / 15 NET
1
83 SF
1
S-1
STORAGE
1 / 300 GROSS
1
1
1
1
NO FURNITURE OR STORAGE OF MATERIALS AT ALCOVE
NO FURNITURE ALLOWED
TYP
3' -8"CLR
EMERGENCY ESCAPE / RESCUE OPENING TO COMPLY WITH OSSC SECTION 10301
IN ACCORDANCE WITH OSSC 1028.4
EGRESS COURT BUILDING OVERHANG ABOVE
TY
P
3' -
8"
CLR
CLR
6' -
7 7
/8"
CLR
7' -
6 3
/4"
TYCO MODEL WS SPECIFIC APPLICATION PENDENT VERTICAL SIDEWALL WINDOW SPRINKLER AT 2-HR FIRE BARRIER ASSEMBLY
SS
SSS
S S S
S S
S
W
W
W
TYCO MODEL WS SPECIFIC APPLICATION PENDENT VERTICAL SIDEWALL WINDOW SPRINKLER 2-HR FIRE BARRIER ASSEMBLY
2HR RATED BARRIRE ALONG EGRESS COURT AND EXIT DISCHARGE, OFFERED AS ADDED MEASURE OF PROTECTION
2 HR RATED HORIZONTAL ASSEMBLY ABOVE OFFERED AS ADDED MEASURE OF PROTECTION
W
W
W
S
S
S
S
S
S
W
STAIR 2
STAIR 1
STAIR 3
STAIR 4EXIT PASSAGEWAY EXIT
PASSAGEWAY
EG
RE
SS
CO
UR
T
2
2
2
45 MINUTE RATED OPENING PROTECTIVE
TERMINATION OF EXIT ACCESS FOR GROUND LEVEL UNITS. EXIT DISCHARGE BEGINS
TERMINATION OF EXIT ACCESS FOR GROUND LEVEL UNIT. EXIT DISCHARGE BEGINS
EXIT DISCHARGE
2
TERMINATION OF EXIT AT THE PUBLIC WAY
2
NO FURNITURE
2
52' -
0"
81' - 0"
3
3
3
W
INDIVIDUALLY ENCASED GLULAM BEAM ABOVE WALL
3
INDIVIDUALLY ENCASED GLULAM BEAM ABOVE WALL3
3
436 SF
3
R-2
APARTMENT
1 / 200 GROSS
407 SF
3
R-2
APARTMENT
1 / 200 GROSS
304 SF
2
R-2
APARTMENT
1 / 200 GROSS
399 SF
2
R-2
APARTMENT
1 / 200 GROSS
301 SF
2
R-2
APARTMENT
1 / 200 GROSS
306 SF
2
R-2
APARTMENT
1 / 200 GROSS
301 SF
2
R-2
APARTMENT
1 / 200 GROSS
375 SF
2
R-2
APARTMENT
1 / 200 GROSS
378 SF
2
R-2
APARTMENT
1 / 200 GROSS
DIA
GONAL
DIS
TANCE =
66' -
8"
MIN
IMUM
EXIT
SEPER
ATION D
ISTAN
CE =
22' -
2"
DIAG
ONAL D
ISTANCE = 67' - 2"
MIN
IMUM
EXIT SEPERATIO
N D
ISTANCE = 22' - 4"
52' -
0"
1 HR RATED EXTERIOR WALL, RATED FOR EXPOSURE FROM BOTH SIDES, PER TABLE 602 AND SECTION 705.5. TYP AT WALLS WITHIN 10' OF PROPERTY LINE
G0.21
2
3
G0.22
4
G0.22
5
G0.22
52' -
0"
6' -
11"
G0.21
4
G0.21
5
EAST BUILDINGWEST BUILDING
11
1
1
1
1
1 HR RATED EXTERIOR WALL, RATED FOR EXPOSURE FROM BOTH SIDES, PER TABLE 602 AND SECTIONS 705.3 & 705.5.
1
NUMBER
25
5" 32"
2
150 SF
B
USE
1 / 100 GROSS
OCCUPANT LOAD SERVED
CLEAR WIDTH PROVIDED
CLEAR WIDTH CALCULATED PER OSSC 1005.3
USE
OCCUPANCY CLASSIFICATION
FLOOR AREA
OCCUPANT LOAD FACTOR (OCCUPANTS PER SQUARE FOOT)
OCCUPANT LOAD
PATH OF TRAVELX'-X"
FIRE-RESISTANCE RATING
EGRESS PATH
ROOM / SPACE OCCUPANCY TAG
EGRESS COMPONENT TAG
EGRESS PATH - PROVIDE ILLUMINATION LEVEL NOT LESS THAN 1 FOOTCANDLE MEASURED AT THE WALKING SURFACE. PROVIDE EMERGENCY POWER PER OSSC 1008.3.5
EXIT SIGN
SYMBOLS
2-HOUR FIRE RESISTANCE RATING
1-HOUR FIRE RESISTANCE RATING
1-HOUR FIRE PROTECTED STEEL COLUMN, SEE 1/A8.06S
1-HOUR FIRE PROTECTED WOOD COLUMN, SEE 3/A8.06W
2-HOUR INDIVIDUAL ENCASED BEAM ABOVE, SEE 4/A8.06
2-HOUR FIRE PROTECTED STEEL COLUMN, SEE 2/A8.06S
2-HOUR HORIZONTAL CEILING ASSEMBLY ABOVE. SEE 8/A8.01
FECFIRE EXTINGUISHER CABINET
1-HOUR INDIVIDUAL ENCASED BEAM ABOVE, SEE 4/A8.06 (STEEL) & 8/A8.06 (WOOD)
NOTE: WHERE FIRE RESISTANCE RATING IS INDICATED AT EXTERIOR WALLS, WALL IS TO BE CONSTRUCTED PER OSSC 705. SEE CODE PLANS FOR LOCATIONS WHERE RATING IS REQUIRED AT BOTH SIDES OF WALL
2
FIRE PARTITION (WHERE RESITANCE RATING IS INDICATED)
FIRE BARRIER
NOTE: WHERE INDIVIDUAL ENCASEMENT IS NOT REQUIRED FOR BEAMS AND COLUMNS PER OSSC 704.4.1 & 704.4.2, FIRE RESISTANCE RATING IS TO BE PROVIDED BY THE MEMBRANE RATING OF THE HORIZONTAL ASSEMBLY OR WALL ASSEMBLY, RESPECTIVELY
2
3
LEVEL 1 - LOBBY(WEST)1' - 10"
LEVEL 214' - 4"
LEVEL 324' - 6"
LEVEL 434' - 8"
ROOF45' - 0"
LEVEL 1 - RETAIL0' - 0"
A B.1 C D E.1 F.1 G H
TO PARAPET48' - 6"
[R-2] - APARTMENT
[R-2] - APARTMENT
[R-2] - APARTMENT
[R-2] - APARTMENT
[R-2] - APARTMENT
[R-2] - APARTMENT
[R-2] - APARTMENT
[R-2] - APARTMENT [M] - RETAIL
[R-2] - APARTMENT
[R-2] - APARTMENT
[R-2] - APARTMENT
[S-1] - ELEC
[R-2] - APARTMENT
[R-2] - APARTMENT
[R-2] - APARTMENT
B.2 E.3 F.2E.2
LEVEL 1 - LOBBY(EAST)
1' - 3"
EAST BUILDINGWEST BUILDING
11
1 1
[R-2] CORR
[R-2] CORR
[R-2] CORR
[R-2] CORR
[R-2] CORR
[R-2] CORR
LEVEL 214' - 4"
LEVEL 324' - 6"
LEVEL 434' - 8"
ROOF45' - 0"
LEVEL 1 - RETAIL0' - 0"
13.55 2.5 1.523
TO PARAPET48' - 6"
[M] - RETAIL
[R-2] - APARTMENT
[R-2] - APARTMENT
[R-2] - APARTMENT
[R-2] -APARTMENT
[R-2] -APARTMENT
[R-2] -APARTMENT
4 1.1
CLR
7' - 9 3/4"
PER 1028.4.2, WALL ALONG EGRESS COURT TO BE 1-HOUR FIRE RESISTANCE RATED MINIMUM. 2HR RATED ASSEMBLY OFFERED AS ADDED MEASURE OF PROTECTION
CLR
12' -
6"
1
1
LEVEL 1 - LOBBY(WEST)1' - 10"
LEVEL 214' - 4"
LEVEL 324' - 6"
LEVEL 434' - 8"
ROOF45' - 0"
13.55 2.5 1.5
TO PARAPET48' - 6"
[R-2] - APARTMENT
[R-2] - APARTMENT
[R-2] - APARTMENT
[R-2] APARTMENT
[R-2] - APARTMENT[R-2]
LOBBY
1
[R-2] APARTMENT
[R-2] APARTMENT
1. SEE MECHANICAL AND PLUMBING DRAWINGS FOR LOCATIONS OF PENETRATIONS AT FIRE RATED ASSEMBLIES AND APPLICABLE PROTECTION.
2. SEE A/8.02 FOR TYPICAL PENETRATION DETAILS
3. ALL BATHROOM FANS TO BE TESTED AND LISTED FOR USE IN FIRE-RESISTANCE RATED CEILINGS AND INSTALLED IN ACCORDANCE WITH THE LISTING INSTRUCTIONS.
4. ALL LIGHTING AT FIRE-RESISTANCE RATED CEILINGS TO BE SURFACE MOUNTED.
5. ANULAR AREAS OF ALL MEMBRANE PENETRATIONS TO BE 1/8" MAX UNLESS LISTED OTHERWISE
REVISIONS
This document is an instrument of service prepared by William Kaven Architecture, which owns all common
law, statutory and other rights with regard to it, including copyright. This document may be used only
for permitted purposes in connection with the indicated project. Other uses are prohibited without the express
written consent of William Kaven Architecture.
JOB NO.
© MMXIX WILLIAM KAVEN ARCHITECTURE
DRAWING NO.
DATE
DRAWING TITLE
WILLIAM KAVEN ARCHITECTURE4075 N. WILLIAMS AVE, STUDIO 440
PORTLAND, OR 97227
www.williamkaven.com
CITY STAMP
PROJECT
3755-3763 N WILLIAMS AVE
PORTLAND, OR 97227
G0.22
19.02
3733 N
WIL
LIA
MS
PERMITSUBMITTAL
NOVEMBER 13, 2020
LIFE SAFETY
PLANS LEVELS 1
AND 2
1/8" = 1'-0"01LEVEL 1 LIFE SAFETY PLAN
1/8" = 1'-0"02LEVEL 2 LIFE SAFETY PLAN
OCCUPANT LOAD - LEVEL 1
ROOM NAME OCCUPANCY AREAAREA PEROCCUPANT
OCCUPANTLOAD
RETAIL M 709 SF 60 SF 12
APARTMENT R-2 310 SF 200 SF 2
APARTMENT R-2 383 SF 200 SF 2
APARTMENT R-2 394 SF 200 SF 2
COURTYARD R-2 418 SF 15 SF 28
LOBBY R-2 54 SF 15 SF 4
ELECTRICAL S-1 89 SF 300 SF 1
MECH S-1 20 SF 300 SF 1
STORAGE S-1 49 SF 300 SF 1
STORAGE S-1 83 SF 300 SF 1
TRASH S-1 278 SF 300 SF 1
WATER RISER S-1 42 SF 300 SF 1
2829 SF 56
OCCUPANT LOAD - LEVEL 2
ROOM NAME OCCUPANCY AREAAREA PEROCCUPANT
OCCUPANTLOAD
APARTMENT R-2 378 SF 200 SF 2
APARTMENT R-2 375 SF 200 SF 2
APARTMENT R-2 301 SF 200 SF 2
APARTMENT R-2 306 SF 200 SF 2
APARTMENT R-2 301 SF 200 SF 2
APARTMENT R-2 407 SF 200 SF 3
APARTMENT R-2 304 SF 200 SF 2
APARTMENT R-2 399 SF 200 SF 2
APARTMENT R-2 436 SF 200 SF 3
3206 SF 20
LIFE SAFETY PLAN LEGEND
1" = 10'-0"03CODE BUILDING SECTION
1" = 10'-0"04CODE BUILDING SECTION - EAST BUILDING
1" = 10'-0"05CODE BUILDING SECTION - WEST BUILDING
1 PERMIT REV 1 4/2/21
2 PERMIT REV2 7/14/21
3 PERMIT REV 3 Date 3
1
1
1
1
1FIRE RATED PENETRATIONS GENERAL NOTES
1
2