3508/3504
-
Upload
hamish-potter -
Category
Documents
-
view
16 -
download
0
description
Transcript of 3508/3504
3508/3504
What is the 3500 Range?
• Not a 2400 replacement!
• 818/902 performance controller/programmer
• 2408/2404 compatible terminals assignment
• 2400 simplicity with 2604 flexibility
• Flexible configuration tools for creative solutions
Where should we sell it?
• Aerospace & Defence– Heat Treatment, composite curing, environmental test
• Semiconductor– Crystal growing, MBE, CVD, environmental test
• Automotive– Heat treatment, paint drying, environmental test
• Bricks & Ceramics– Drying, firing, glazing
• Glass– , Forehearth heating, annealing lears
• Pharmaceutical– Fermentation, culture growth, freeze dryers, reactors
• Process Applications– Flow dosing
• Precision 1uV main PV input
• Single PID loop
• 50 programs, 200 segments
• Maths, logic & timer functions
• 3508 supports up to 3 I/O modules
• 3504 supports up to 6 I/O module
3500 Range Summary
3504 - 96x 96mm
3508 - 96x 48mm
• Graphical configuration tools
• Front panel IR communication interface
• Built in- logic I/O & relay
• 24Vdc transmitter PSU
• Uses digital I/O Expander
3500 Range Summary
41/2 Digit PV Display
Programmer HomeScreen
•Setpoint•Time Remaining•Program Number•Segment Number
Alarm Beacon
PV Units
Output/ Status Beacons
Infrared Communication Port
10 x 4 Character, Graphic/ Text display Large SP
Display
3508 Display Concept
Display Units
5 digit PV
Output/ Status Beacons
Alarm Beacon
Infrared Communication Port
Programmer HomeScreen
•Setpoint•Time Remaining•Program Number•Segment Number
20 x 4 Character, Graphic/ Text display
Large SP Display
51 point Bar Graphwith alarm indication
3504 Display Concept
3500 Terminations
L
N
LA
LB
LC
AA
AB
AC
VI
V+
V-
HA
HB
HC
HD
HE
HF
JA
JB
JC
JD
JE
JF
1A
1B
1C
1D
2A
2B
2C
2D
3A
3B
3C
3DmV/V
mA
Logic IO A
Logic IO B
Logic IOCommon
Live
Neutral
Earth
IO m
od
ule
3
Co
mm
s ch
an
ne
l 2
IO m
od
ule
1
Co
mm
s ch
an
ne
l 1
IO m
od
ule
2
3508
NO
NC
C
L
N
LA
LB
LC
AA
AB
AC
VI
V+
V-
HA
HB
HC
HD
HE
HF
JA
JB
JC
JD
JE
JF
1A
1B
1C
1D
2A
2B
2C
2D
3A
3B
3C
3D
4A
4B
4C
4D
5A
5B
5C
5D
6A
6B
6C
6DmV/V
mA
Logic IO A
Logic IO B
Logic IOCommon
Live
Neutral
Earth
IO m
od
ule
3
Co
mm
s ch
an
ne
l 2
IO m
od
ule
1
IO m
od
ule
4IO
mo
du
le 5
IO m
od
ule
6
Co
mm
s ch
an
ne
l 1
IO m
od
ule
2
1
3
2
6
5
4
3504
NO
NC
C
Logic out - 24V/15mAlogic input
24Vdc transmitter supply
Note: RTD terminals as 26/27
3508/04 Modular I/O
• Output modules– Change over relay– 2 Pin relay– Dual relay– Single triac– Dual triac– Analog DC control– Analog DC
retransmission– Isolated single logic– Triple logic
• Power supply modules– 24Vdc transmitter supply– 5/10Vdc transducer supply
• Communication modules– 232 Modbus RTU– 2 wire 485 Modbus RTU– 4 wire 485 Modbus RTU– IO Expander
• Input modules– Analog input(26/27(AM) module)
» Not Slots 2 or 5– Triple logic input– Triple contact input– Potentiometer input
Control Options
• Single PID loop– PID, ON/OFF– VP Heat/VP Cool– PID Heat/VP Cool etc
• Advanced control features– Flexible wiring of function blocks– Similar functionality to single loop 2604– Configured using iTools Graphical Editor
Setpoint Programmer
• 50 Programs, 200 Segments– Various ordering options
• Single SP profile• 8 Digital event outputs• Segment types
– Rate, Dwell, Step, Target, Call, End• Digital inputs
Toolkit Functions
• Maths functions– 2 input x 24 – 8 input switch x 4– User value x 16
• Logic functions– 2 input x 24– 8 input x 2
• Timer functions– Real time clock– Timer x 4– Counter x 2– Totaliser x 2
• Other functions include– Transducer Scaling x 2– Custom Linearisation x 2– Switchover– Load simulation
User Pages
• 8 Pages• 64 Parameters• Various display formats
Recipes
• 8 Sets, each set can a given meaningful name• 24 Tags(parameters) per set• Typical example of Tags; Control SPs, Alarm SPs,
PID values etc• Sets can be selected by HMI or communications
Modbus RTU
SCADA/DCS
Communications
• Modbus RTU slave• Master Modbus RTU
– Broadcast of single parameter
• More options coming soon
Infra Red Clip
• In-Situ Communications• No loss of sealing• Commissioning• Cloning• Diagnostics
Order Code - Hardware & Functions
20
Order Code - IO Modules
Quick Start HMI
• Quick Start HMI provides an intuitive series of questions to allow a user to configure a simple 3500 application without itools
• Enables all blocks in 3500 and makes wires
Future Development
• Phase 1A - April 04– More communication options
» Profibus DP, DeviceNet, EI-Bisync– Supports IO Expander– Zirconia block– Quick start HMI
• Phase 2 – Late Summer 04– 2 PID loops– 2 Setpoint profiles– Programmer PV events– Ethernet Modbus TCP/IP
• What we are doing next– Cascade, override, ratio– Master Modbus
Why Buy 3500?
• Flexible and competitive controller» Single loop 2604 at lower cost
• Easy and fast configuration» Saves time, money and easier to be right first time
• 0.1% Measurement accuracy» High performance control at 2400 costs
• Wide selection of IO modules» Reduces spares holding
» Caters for more applications
• Configurable and intuitive display » Provides clear view of current process state
» Recipes simplify process changes
» Available in languages other than English