3443-SZ-RT-101_04 Attachment 9-3 HAZOP Worksheet Close Out Session
Transcript of 3443-SZ-RT-101_04 Attachment 9-3 HAZOP Worksheet Close Out Session
HDPE SPEEDBIRD PLANT SAFETY REPORT
ATTACHMENT 9.3 - HAZOP WORKSHEET CLOSE OUT SESSION
3443-SZ-RT-101 Attachment 9
Plant: 320 KT/Y HDPE Client: Basell Polyolefins Location: Münchsmünster Sheet 7 of 20 Issue 04
Node: 1. Updating of piping and instrumentation on pellet deodorizing unit Drawings: 3443-XZ-DM- 581, 582; 3443-T-MF-0081 & 0100
Items: 2D-5801 Pellet Deodorizer
2D-5802 Feding Hopper
2RF-5801 Deodorizer Rotary Feeder
2RF-5803 Deodorizer Inlet Rotary Feeder
2E-5801 Deodorizer Condenser
Deviation Causes Consequences Safeguards Recommendations By
1 No/ Less Flow 1.1 No new issue
2 More Flow 2.1 No new issue
3 Reverse Flow 3.1 No new issue
4 High Pressure 4.1 4.1.1 4.1.1.1
5 Low Pressure 5.1 No new issue
6 High Temperature 6.1 No new issue
7 Low Temperature 7.1 No new issue
8 Low Level 8.1 No new issue
9 High Level 9.1 No new issue
Opening of nitrogen line when slide valve 2HY58104 below 2D5802 is kept closed
Possible overpressurization of rotary feeder 2RF5801 and 2RF5803
Slide valve 2HY58104 is kept locked open.
HDPE SPEEDBIRD PLANT SAFETY REPORT
ATTACHMENT 9.3 - HAZOP WORKSHEET CLOSE OUT SESSION
3443-SZ-RT-101 Attachment 9
Plant: 320 KT/Y HDPE Client: Basell Polyolefins Location: Münchsmünster Sheet 8 of 20 Issue 04
Node: 2. Drawings: 3443-XZ-DM-582; 3443-T-MF-0081 & 0100
Items: 2D-5804 Pellet Conveying Pick-up Vessel
2D-5805 Conveying Water Buffer Vessel
2D-5806 Pellet Receiver
2RF-5802 Deodorizer Outlet Rotary Feeder
2P-5802 A/B Conveying Water Pump
2C-5802 Pellet Dryer Fan
2S-5801 Pellet Dryer
2E-5802 Conveying Water Cooler
Deviation Causes Consequences Safeguards Recommendations By
1 No/ Less Flow 1.1 1.1.1 1.1.1.1 2FAL58201 1
2 More Flow 2.1 No new issue
3 Reverse Flow 3.1 No new issue
4 High Pressure 4.1 No new issue
5 Low Pressure 5.1 No new issue
6 High Temperature 6.1 6.1.1 6.1.1.1
Updating of piping and instrumentation on deodorized pellet dryer system
No flow of Nitrogen to 2D5804 due to malfunction 2FIC58201.
Loss of Blanketing in 2D5804 leading to possible carryover of Oxygen in deodorizer and Off-Gas system. Actually the blanketing seems to be prevented by a vent line from 2D5804 to safe location
Check with Coperion if it is correct to vent directly from 2D5804 or if the vent shall be relocated to the seal pot, in order to maintain the blanketing function.
TCM / Coperion
Malfunction of 2TIC58202, loss of cooling
Troubles in palletizing section due to too hot pellets
2TAH58202 in case of loss of cooling
HDPE SPEEDBIRD PLANT SAFETY REPORT
ATTACHMENT 9.3 - HAZOP WORKSHEET CLOSE OUT SESSION
3443-SZ-RT-101 Attachment 9
Plant: 320 KT/Y HDPE Client: Basell Polyolefins Location: Münchsmünster Sheet 9 of 20 Issue 04
Node: 2. Drawings: 3443-XZ-DM-582; 3443-T-MF-0081 & 0100
Items: 2D-5804 Pellet Conveying Pick-up Vessel
2D-5805 Conveying Water Buffer Vessel
2D-5806 Pellet Receiver
2RF-5802 Deodorizer Outlet Rotary Feeder
2P-5802 A/B Conveying Water Pump
2C-5802 Pellet Dryer Fan
2S-5801 Pellet Dryer
2E-5802 Conveying Water Cooler
Deviation Causes Consequences Safeguards Recommendations By
7 Low Temperature 7.1 Malfunction of 2TIC58202 7.1.1 7.1.1.1 None 2 TCM
8 Low Level 8.1 8.1.1 8.1.1.1 2LAL58210.1
9 High Level 9.1 No new issue
Updating of piping and instrumentation on deodorized pellet dryer system
Wet pellets in the deodorizer pellet receiver and in downstream section
Install an independent low temperature alarm on 2D5804
Low level in water seal due to drain valve left inadvertently open
Loss of Blanketing in 2D5804 leading to possible carryover of Oxygen in deodorizer and Off-Gas system. Actually the blanketing seems to be prevented by a vent line from 2D5804 to safe location
HDPE SPEEDBIRD PLANT SAFETY REPORT
ATTACHMENT 9.3 - HAZOP WORKSHEET CLOSE OUT SESSION
3443-SZ-RT-101 Attachment 9
Plant: 320 KT/Y HDPE Client: Basell Polyolefins Location: Münchsmünster Sheet 10 of 20 Issue 04
Node: 3. Addition of knife valve and modification of logic downstream 2D 5102 Drawings: 3443-XZ-DM-511C; 3443-T-MF-0088
Items: 2D 5102 Intermediate HDPE and Polybutene Pellet Bin
Deviation Causes Consequences Safeguards Recommendations By
1 No/ Less Flow 1.1 1.1.1 Offspec product
1.1.1.1
1.1.1.2
1.1.1.3
2 More Flow 2.1 No new issue
3 Reverse Flow 3.1 No new issue
4 High Pressure 4.1 No new issue
5 Low Pressure 5.1 No new issue
6 High Temperature 6.1 No new issue
7 Low Temperature 7.1 No new issue
8 Low Level 8.1 No new issue
9 High Level 9.1 No new issue
10 Hazard requirements
10.1 10.1.1 Spillage of pellets10.1.1.1
TCM10.1.1.2
10.2 10.1.2 Static discharge 10.1.2.1
No flow of polybutene / recycle pellets due to 2XV51101 malfunction / close
2FAL-51112 provided on the weighing stationLimit Switch 2HZLL-51101 provided on DCSDownstream product quality checking provided
Inadvertent opening of 2HV-51101 when loading truck is not in position
Operating procedure to open first 2HV-51101 and then slide valve 2H/Y51101C Consider to provide
Grounding on the bottom of discharge pipe to be connected to the truck.
Limit Switch 2HZLH-51101 provided on DCS
Inadvertent opening of 2HV-51101 when loading truck is not connected to earth
Limit Switch 2HZLH-51101 provided on DCS
HDPE SPEEDBIRD PLANT SAFETY REPORT
ATTACHMENT 9.3 - HAZOP WORKSHEET CLOSE OUT SESSION
3443-SZ-RT-101 Attachment 9
Plant: 320 KT/Y HDPE Client: Basell Polyolefins Location: Münchsmünster Sheet 11 of 20 Issue 04
Node: 4. Addition of pressure transmitter and interlock on waste gas line of D4103 Drawings: 3443-XZ-DM-413; 3443-T-MF-0108
Items: 2D-4103 Al-Alkyl Storage Tank
Deviation Causes Consequences Safeguards Recommendations By
1 No/ Less Flow 1.1 No new issue
2 More Flow 2.1 No new issue
3 Reverse Flow 3.1 No new issue
4 High Pressure 4.1 4.1.1 4.1.1.1
5 Low Pressure 5.1 No new issue
6 High Temperature 6.1 No new issue
7 Low Temperature 7.1 No new issue
8 Low Level 8.1 No new issue
9 High Level 9.1 No new issue
Malfunction of the blanketing system
Possible increase of pressure in 2D4103 exceeding the design pressure of TEAL Container
2PAH 41303 activating 2S410301 closing TEAL and Hexane from TEAL Container
HDPE SPEEDBIRD PLANT SAFETY REPORT
ATTACHMENT 9.3 - HAZOP WORKSHEET CLOSE OUT SESSION
3443-SZ-RT-101 Attachment 9
Plant: 320 KT/Y HDPE Client: Basell Polyolefins Location: Münchsmünster Sheet 12 of 20 Issue 04
Node: 5. Addition of flare dip pot discharge 5D 6802 and pumps 5P 6801 A/B Drawings:
Items: 5D 6802 Flare Dip Pot Discharge
5P 6801A/B Flare Discharge Pumps
Deviation Causes Consequences Safeguards Recommendations By
1 No/ Less Flow 1.1 Low level in flare water seal 1.1.1 1.1.1.1
1.2 1.1.2 1.1.1.2 5LAL68102 tripping the pump
2 More Flow 2.1 No new issue
3 Reverse Flow 3.1 No new issue
4 High Pressure 4.1 No new issue
5 Low Pressure 5.1 No new issue
6 High Temperature 6.1 6.1.26.1.2.1 5TAH68136
6.1.2.2
7 Low Temperature
7.1 Failure of heat tracing
7.1.2
7.1.2.1 5TAL68136
7.2 7.1.2.2
3443-XZ-DM-333B,681,681A; 3443-T-MF-0122
Connection between flare water seal and waste water tank D3304
Deep pipe connection in waste water and goose neck provision on the line to waste water tank
Manual valve on 2D56802 left inadvertently close
Pump running dry. No major issue
High flow of steam to flare water seal
Low level in case temperature reaches 100degC Safeguards against low level in
5D6802
Increase of level in 5D6802 with possible overfilling leading to level and backpressure increase in flare system
Extreme low ambient temperature
Safeguards against high level in 5D6802
HDPE SPEEDBIRD PLANT SAFETY REPORT
ATTACHMENT 9.3 - HAZOP WORKSHEET CLOSE OUT SESSION
3443-SZ-RT-101 Attachment 9
Plant: 320 KT/Y HDPE Client: Basell Polyolefins Location: Münchsmünster Sheet 13 of 20 Issue 04
Node: 5. Addition of flare dip pot discharge 5D 6802 and pumps 5P 6801 A/B Drawings:
Items: 5D 6802 Flare Dip Pot Discharge
5P 6801A/B Flare Discharge Pumps
Deviation Causes Consequences Safeguards Recommendations By
8 Low Level in 5D68028.1 Low level in flare water seal 8.1.1 8.1.1.1
8.2 8.1.2 8.1.1.2 5LAL68102 tripping the pump
9 High Level in 5D6802
9.1
9.1.1
9.1.1.1
9.2 Malfunction of 5LT68102 9.1.1.2
9.3 Failure of heat tracing 9.1.1.3
9.1.1.4 Spare pump provided
10 Contamination 10.1 10.1.110.1.1.1 Spare pump provided
10.1.1.2
11 Instrument air failure 11.1 11.1.1 11.1.1.1
3443-XZ-DM-333B,681,681A; 3443-T-MF-0122
Connection between flare water seal and waste water tank D3304
Deep pipe connection in waste water and goose neck provision on the line to waste water tank
Manual valve on 2D56802 left inadvertently close
Pump running dry. No major issue
Failure of the pump 5P6801A/B
Overfilling of 5D6802 leading to level and backpressure increase in flare system
5LAH68102 if the failure is not in the transmitter
5LAHH68101 independent high high level alarm
5LAH68177 and 5LAHH68176 in flare water seal
Failure of pumps 5P6801A/B in case of hydrocarbon presence in flare water seal
Accumulation of hydrocarbon in 5D6802 leading to possible accumulation of hydrocarbons in flare system
Safeguard against high level in 5D6802
Steam and water valve failing open
Continuous flow discharging in the water seal leading to high level and high temperature
Safeguard against high level and high temperature in 5D6802
HDPE SPEEDBIRD PLANT SAFETY REPORT
ATTACHMENT 9.3 - HAZOP WORKSHEET CLOSE OUT SESSION
3443-SZ-RT-101 Attachment 9
Plant: 320 KT/Y HDPE Client: Basell Polyolefins Location: Münchsmünster Sheet 14 of 20 Issue 04
Node: 6. Drawings: 3443-XZ-DM-611, 612, 612A, 614
Items: 2E-6101B 2nd Chiller Evaporator
2P-6101C 3rd Cold Hexane Pump
2Z-6101C 3rd Cold Hexane Pump Seal Pot
Deviation Causes Consequences Safeguards Recommendations By
1
1.1 2P6101A/B/C Failure
1.1.1
1.1.1.1
1.2 1.1.1.2
2 More Flow 2.1 No new issue
3 Reverse Flow 3.1 No new issue
4 High Pressure 4.1 No new issue
5 Low Pressure 5.1 No new issue
6
6.1 2LV61262 fails open
6.1.1
6.1.1.1
6.2 6.1.1.2
7 Low Temperature 7.1 No new issue
Refrigeration Unit - Addition of 2nd Evaporator and 3rd Pump on cold hexane distribution system
No/ Less Flow to 2E6101B
No chilled hexane supplied to the plant leading to upset in downstream section
2 pumps are running and one spare. Flow will be interrupted only in case of contemporarily double failure of the pump
See causes of no flow in Cold Hexane Distribution Main HAZOP
Safeguards in the downstream section
High Temperature in 2E6101B
Chilled Hexane supply temperature higher leading to upset in the downstream section
TAH 61101 in cold hexane circuit
See causes of high temperature in Cold Hexane Distribution Main HAZOP
Safeguards in the downstream section
HDPE SPEEDBIRD PLANT SAFETY REPORT
ATTACHMENT 9.3 - HAZOP WORKSHEET CLOSE OUT SESSION
3443-SZ-RT-101 Attachment 9
Plant: 320 KT/Y HDPE Client: Basell Polyolefins Location: Münchsmünster Sheet 15 of 20 Issue 04
Node: 6. Drawings: 3443-XZ-DM-611, 612, 612A, 614
Items: 2E-6101B 2nd Chiller Evaporator
2P-6101C 3rd Cold Hexane Pump
2Z-6101C 3rd Cold Hexane Pump Seal Pot
Deviation Causes Consequences Safeguards Recommendations By
8 Low Level 8.1 No new issue
9 High Level 9.1 9.1.1 9.1.1.1
10 Composition 10.1 Tube rupture in E6101B 10.1.110.1.1.1 LAH61261
10.1.1.2
Refrigeration Unit - Addition of 2nd Evaporator and 3rd Pump on cold hexane distribution system
High level in the liquid trap due to liquid propylene carryover in case of propylene condensation (long pipe between cooler and compressor suction)
Liquid propylene to the compressor suction leading to possible damage of C6101
2LAH61229 tripping the compressor
Hexane enters in propylene shell side and possible transfer to compressor C6101 LAHH 61260 tripping the
compressor