Climate Control Products
Cooling Products
General Information .................................. 344General Selection Considerations ........... 345
Air Conditioner Design Features .............. 346
Sizing an Air Conditioner .......................... 347
General Specifications for Air Conditioners ... 348
Side Mounting DTS Series Air Conditioners1200 BTU/H ............................................... 349
Side Mounting DTS Series Air Conditioners2000 BTU/H ............................................... 350
Side Mounting DTS Series Air Conditioners3500 BTU/H ............................................... 351
Side Mounting DTS Series Air Conditioners6000, 8000, 12000 BTU/H ........................ 352
Top Mounting DTT Series Air Conditioners4500 BTU/H ............................................... 354
Side Mounting DTS Series Air Conditioners2000 BTU/H, Stainless Steel -NEMA 3R, 4, 4X ........................................ 355
Air Conditioner Accessories ..................... 356
Blowers and Fans
General Selection Considerations ........... 358
Packaged Twin Blowers,160 to 470 CFM ......................................... 359
Filter FansPF Filter Fans ............................................. 360
Fan Accessories ........................................ 362
Top Mount Fan ........................................... 363
Fan Kits,Fan Grills, AC Fans & Guards, Fan Panels........................................................... 364-365
Filter Fans,Filtered Fan Boxes and Filter Grills .......... 366
Fan Trays,300, 600 and 900 CFM ............................. 368
Heating Products
General Information and Sizing ............... 369
Heaters ...................................................... 370
Fan Heaters ............................................... 370
Control Panel Heater ................................ 371
High Wattage Fan Heater ......................... 372
Electrical Humidity andTemperature Control ................................. 373
Thermostat ................................................ 374
Breather Kit ................................................ 374
Quality Enclosures. Service Excellence. © Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
344
Clim
ate Con
trol P
rod
ucts
Air C
on
ditio
ners
Cooling ProductsGeneral Information
The Need for Environment ControlWith wide spread use of micro-electronics in today’s control systems, temperature management takes on a new priority inorder to ensure steady and reliable performance. The maintenance of a correct operating temperature may combine bothcooling and or heating inside an enclosure which can protect against costly down time and system failures.
The Purpose of CoolingElectrical/electronic control systems together generate heat as a by-product of their operation. When equipment is located inareas where clean dry air for ventilation is either not available or high external temperatures exist, active methods such as airconditioning must be applied.
The Purpose of HeatingHeaters protect electronic and electrical components from temperature problems that are below tolerances. Obviously, thereare circumstances when extremely low ambient (outside cabinet) temperatures would require a heater, but there are also lessapparent times when a heater should be considered. For example, a system may run all day having its components generateheat, but once the system shuts down for the night, the quick drop in temperature could cause condensation and possiblycorrosion - a heater could maintain a safe, constant temperature.
Combined Cooling and HeatingSome components today require both cooling and heating in the same enclosure. When designing your system, be aware ofthe need to maintain a relatively constant temperature inside the enclosure as ambient temperatures swing from cool to veryhot.
Information Needed for Environment Control SelectionThe following information should be on hand to properly size cooling products:(1) Heat to be dissipated (Watts).(2) Maximum temperature expected outside enclosure (°F) or (°C).(3) Maximum allowable internal enclosure temperature (°F) or (°C).(4) Surface area of enclosure (ft2) or (m2).
The following information should be on hand to properly size heating products:(1) Heat being generated by electrical/electronic components (in Watts)(2) Minimum temperature expected outside enclosure (°F) or (°C).(3) Minimum allowable internal enclosure temperature (°F) or (°C).(4) Surface area of enclosure (ft2) or (m2).
Quality Enclosures. Service Excellence.© Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
345
Clim
ate Con
trol Pro
du
cts
Heating and Cooling ProductsGeneral Selection Considerations
ambient.
Cooling
Conditions Solution Advantages Disadvantages
Maximum desired enclosure Oversize the enclosure. Easy to implement, no maintenance. Dissipates small amount of heat.temperature is 10°F or 5°C Maintains NEMA rating of the Larger enclosure size takes upabove maximum outside enclosure. more space.
Install ventilation louvers. Economical solution, very little Dissipates limited amount of heat.maintenance, easy to implement. Dirt, oil or fluids could enter the
enclosure.NEMA rating is affected.
Install filter fans. Less expensive than air/refrigeration Must maintain filters.systems. Relatively high amount of NEMA rating can be affected.heat removed, some termperature Limited use in hostile environmentscontrol by using thermostats. such as chemical applications.
Use an air/air heat exchanger. Easy to install, small power Must maintain filters.consumption, temperature controlvia thermostat. Maintains NEMArating of the enclosure.
Maximum desired enclosure Use an air conditioner. Easy to install. Temperature control Must maintain filter. Cannot betemperature lower than via factory installed thermostat. used when outside temperaturemaximum outside ambient. Removes large amounts of heat. is below 59°F (15°) or above
Maintains NEMA rating of enclosure, 130°F (52°C).dehumidifies enclosure air.
Circulation
Conditions Solution Advantages Disadvantages
Localized heat or 'hot spots'. Install circulation fans in the Economical solution, no maintenance, Dissipates small amount of heat.enclosure. easy to install. Maintains NEMA
rating of the enclosure.
Heating
Conditions Solution Advantages Disadvantages
Outside temperature is below Heat with radiant heater. Economical power consumption. Consumes energy, takes upminimum allowable equipment Reliable, can be temperature internal panel space.operation range. controlled.
Condensation occurs. Heat with radiant heater to Economical power consumption. Consumes energy, takes upmaintain temperature above Reliable, humidity can be controlled. internal panel space.the dewpoint.
Air C
on
ditio
ners
Quality Enclosures. Service Excellence. © Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
346
Clim
ate Con
trol P
rod
ucts
Air C
on
ditio
ners
Side Mounting
Q MountQ Mount allows installation of the airconditioner to be performed by asingle person, saving valuable time and money. Thread-in-Studs hold the unit in place while it is fastened to the enclosure.This also allows for the air conditioner to be easily removedfor safe transportation separate from control equipment.
Lifting top mount units intoplace can be safelyaccommodated with optionallifting lugs which attach to theframe assembly.
Top Mounting
ServiceabilityOne Template Mounting
One singlet e m p l a t eaccommodatescooling rangesfrom 6,000 BTU/H to 12,000
BTU/H. This allowssize upgrades without
making modifications to theexisting cutouts. The additional
height of these units, combined with theirintegrated air ducting ensures maximum air circulation withinthe enclosure, reducing the chance of heat pockets. Smallcapacity units, 1,200 BTU/H and 2,000 BTU/H, areretrofitable to leading North American cutouts allowing easyupgrading or replacement.
The optional recessedmounting frame will reducethe external enclosuredimensions.
Improved serviceabilitybegins with the unique PFfilter grill. This grill providessuperior protection of the
filter mat compared to units with a metal mat and is easilyremoved for cleaning. Quarter turn screws allow the externalcover of the air conditioner to be completely removed forease of inspection and serviceability.
Cooling ProductsAir Conditioner Design Features
Quality Enclosures. Service Excellence.© Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
347
Clim
ate Con
trol Pro
du
cts
Cooling ProductsSizing an Air Conditioner
Sizing an Air ConditionerThe proper selection of an air conditioner is determined by the following steps:
Step 1) Internal heat load quoted as Watts that must be dissipated.Step 2) The exposed surface area of the enclosure.Step 3) Temperature differential required between maximum inside temperature and maximum outside ambient.Step 4) Final calculation of the above.
1 m2 = 10.76 ft2
Calculate the exposed surface area of theenclosure:
1 Watt = 3.413 BTU/H
Determine the internal heat load (in Watts)that must be dissipated.
Step TwoStep One
Step Four(Watts x 3.413) + [1.25 x Area ft2 x DT (°F)] = BTU/H
Step Three
1°C or 1°K∆∆∆∆∆ T=1.8°F∆∆∆∆∆ T
Determine the temperature differential bysubtracting the maximum allowable tem-perature inside the enclosure (Ti) from themaximum ambient temperature outside theenclosure (To).
To-Ti = DT
Capacity RequiredBTU/H. Capacity Rating.
=Area (ft2)144
(Example for freestanding enclosure)
2(h" x w") + 2(h" x d") + (w" x d")
Air C
on
ditio
ners
Quality Enclosures. Service Excellence. © Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
348
Clim
ate Con
trol P
rod
ucts
Air C
on
ditio
ners
Cooling ProductsGeneral Specifications for All Air Conditioners
The DTS/DTT offering is available in the most popular selection of cooling capacities, sizes, voltages and mountingconfigurations. Available capacities range from 1,200 to 12,000 BTU/H in both side mounting and top mounting models. Allmodels use powerful radial fans for maximum air circulation inside the enclosure in ambient temperatures of 125°F (+52°C).Models from 2,000 BTU/H capacity are equipped with thermal expansion valves for optimal use of the evaporator heatexchange surface under all operating conditions. For additional protection of the compressor motor, these valves are suppliedas standard with Maximum Operating Pressure control devices (MOP). For energy conservation, the use of hot gas bypassvalves is limited to the unloaded starting and control of large compressors from 8,000 BTU/H upwards.All air conditioners were developed, designed and subject to final inspections in accordance with international standards.
Construction: Outer shell of sheet steel.
Finish: Durable electrostatic powder coat in RAL7032 beige. Contact Hammond for special colorquotations.
Closed Loop Cooling: Maintains NEMA 12/IP 54 rating of the enclosure. Ambient outside air is never mixed with clean dryenclosure air.
Gasketing: Is provided and/or installed on all units to maintain NEMA 12/IP 54 ratings.
Templates: Provided on all units for easy layout of cutouts and mounting.
Power: Available in 115 V 60 Hz, 110 V 50 Hz and 230 V 50/60Hz.
Cord: Included on all units - 3 wire type SJT 1813 AWG, 115 V 60 Hz units below 14 amps are terminatedwith a plug.
Filter: Removable filter mat made from synthetic fibers are reusable and can be rinsed clean.
Refrigerants: All models use environmentally friendly R134a.
Fans: All blower motors are thermal protected and sealed with permanent lubricants.
Condensate Disposal: Built in condensate evaporators are standard on all but the 1200 BTU model. All units feature acondensate drain fitting complete with hose attachment.
Insulation: Cold components, lines and evaporator compartment insulated for maximum efficiency andprotection against condensation.
Quality Assurance: Prior to charging, the refrigeration system is hermetically sealed with all joints brazed underprotection gas atmosphere to exclude any internal scale. After a thorough leak test every unitundergoes safety and function checks, then is serialized and packed into sturdy boxes prior toshipment.
Installation Manuals: Included with all models are detail drawings, mounting, schematic and wiring diagrams, a troubleshooting checklist and warranty information.
Side Mount Air Conditioners
Rating RatedPart No. BTU/H Voltage Hz Height Width Depth
DTS1200A115 1,200 115 60 13.00 14.76 7.48
DTS1200A230 1,200 230 50/60 13.00 14.76 7.48DTS2000A115 2,000 115 60 17.52 12.40 10.04
DTS2000A230 2,000 230 50/60 17.52 12.40 10.04DTS3500A115 3,500 115 60 36.00 15.35 7.87
DTS3500A230 3,500 230 50/60 36.00 15.35 7.87DTS6000A115 6,000 115 60 53.15 15.35 7.87
DTS6000A230 6,000 230 50/60 53.15 15.35 7.87DTS8000A115 8,000 115 60 53.15 15.63 10.63
DTS8000A230 8,000 230 50/60 53.15 15.63 10.63DTS12000A115 12,000 115 60 53.15 15.63 10.63
DTS12000A230 12,000 230 50/60 53.15 15.63 10.63DTS2000A115N4SS 2,000 115 60 19.04 16.09 15.08
DTS2000A230N4SS 2,000 230 60 19.04 16.09 15.08
A115 units can be operated 50 Hz at 110 V
Top Mount Air Conditioners
Rating RatedPart No. BTU/H Voltage Hz Height Width Depth
DTT4500A115 4,500 115 60 15.94 23.62 15.35DTT4500A230 4,500 230 50/60 15.94 23.62 15.35
A115 units can be operated 50 Hz at 110 V
Product Summary
Quality Enclosures. Service Excellence.© Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
349
Clim
ate Con
trol Pro
du
cts
Part Number Ship Wt. lbs
DTS1200A115 42
DTS1200A230 42
Refrigeration Data
Rated Capacity 1,200 BTU/H (350 Watts)
Type of Refrigerant R134aRefrigerant Charge 280 g
Adjustable Thermostat Factory setting +95°F (+35°C)Max. Ambient Air Temp. +125°F (+52°C)
Min. Ambient Air Temp. +46°F (+8°C)Air Capacity (unrestricted) Internal Circulation 106 CFM
External Circulation 230 CFM
Condensate Discharge Direct via tubeFilter Mat 150 g/m²
Db Noise Level < 62 dB(A)Unit Weight 40 lbs (18 kg)
Exterior Case Galvanized sheet steelFinish RAL7032 beige powder finish
NEMA Rating Enclosures IP 54/NEMA 12
Technical Data
Electrical Data DTS1200A115 DTS1200A230
Rated Voltage 115 V 60 Hz 230 V 50/60 Hz110 V 50 Hz
Range of Operation 103-127 V 207-253 VPower Consumption 200 W 200 W
Running Amps 2.2 A 1.3/2.5 AStarting Current 15.7 A 9.5/13.0 A
Line Cord With plug Without plug
Drilling TemplateRight Side View Front View
Side Mounting DTS Series1200 BTU/H
DescriptionDesigned for side mounting on anyenclosure surface where hot spotcooling or low capacity cooling isrequired.Compact design uses minimalsurface area.
Closed loop cooling ensures cleanenclosure air is recirculated withoutever mixing with contaminatedambient air.
StandardsMaintains enclosure's NEMA 12ratingIP 54UR, cUR and CE
FeaturesR134a refrigerant.Thermostat control.Continuous air circulation from highcapacity fans.EMI/RFI suppression meets CE.Line cord with plug (115 V).
Washable filter mat protected withinan easily removable grill.Gasket, mounting kit and templatefor enclosure cutout and drilling areincluded.Condensate drain hose and clampprovided.Exterior case easily removable forfield service.Q Mount allows unit to hang in placefor easy installation.
AccessoriesGaskets...see page 356Replacement filters...see page 356Replacement grill...see page 356
Air C
on
ditio
ners
Quality Enclosures. Service Excellence. © Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
350
Clim
ate Con
trol P
rod
ucts
Air C
on
ditio
ners
Refrigeration Data
Rated Capacity 2,000 BTU/H (580 Watts)
Type of Refrigerant R134aRefrigerant Charge 300 g
Adjustable Thermostat Factory setting +95°F (+35°C)Max. Ambient Air Temp. +125°F (+52°C)
Min. Ambient Air Temp. +46°F (+8°C)Air Capacity (unrestricted) Internal Circulation 230 CFM
External Circulation 230 CFM
Condensate Discharge Condensate evaporatorFilter Mat 150 g/m²
Db Noise Level < 62 dB(A)Unit Weight 51 lbs (23 kg)
Exterior Case Galvanized sheet steelFinish RAL7032 beige powder finish
NEMA Rating Enclosures IP 54/NEMA 12
Part Number Ship Wt. lbs.
DTS2000A115 54
DTS2000A230 54
Technical Data
Electrical Data DTS2000A115 DTS2000A230
Rated Voltage 115 V 60 Hz 230 V 50/60 Hz110 V 50 Hz
Range of Operation 103-127 V 207-253 VPower Consumption 270 W 230 W
Running Amps 2.9 A 1.3 AStarting Current 13.8 A 7.4 A
Line Cord With plug Without plug
Side Mounting DTS Series2000 BTU/H
DescriptionCompact design for side mountingon any enclosure surface where hotspot cooling or low capacity coolingis required.Closed loop cooling ensures cleanenclosure air is recirculated withoutever mixing with contaminatedambient air.
StandardsMaintains enclosure's NEMA 12 ratingIP 54UR, cUR and CE
FeaturesR134a refrigerant.Thermostat control.Line cord with plug (115 V).Washable filter mat protected withinan easily removable grill.
Expansion valve permits increasedefficiency through improvedevaporator heat transfer and lessfrequent compressor operation.Built in condensate evaporator.Continuous air circulation from highcapacity fans.EMI/RFI suppression meets CE.Gasket, mounting kit and templatefor cutout and drilling are included.Condensate drain hose and clamp.Exterior case easily removable forfield service.Q Mount allows unit to hang in placefor easy installation.
AccessoriesGaskets...see page 356Replacement filters...see page 356Replacement grill...see page 356
Drilling Template Left Side View Front View
Quality Enclosures. Service Excellence.© Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
351
Clim
ate Con
trol Pro
du
cts
Part Number Ship Wt. lbs.
DTS3500A115 99
DTS3500A230 99
Refrigeration Data
Rated Capacity 3500 BTU/H (1,014 Watts)Type of Refrigerant R134aRefrigerant Charge 480 gAdjustable Thermostat Factory setting +95°F (+35°C)Max. Ambient Air Temp. +125°F (+52°C)Min. Ambient Air Temp. +46°F (+8°C)Air Capacity (unrestricted) Internal Circulation 247 CFM
External Circulation 341 CFMCondensate Discharge Condensate evaporatorFilter Mat 150 gDb Noise Level < 64 dB(A)Unit Weight 94 lbs (43 kg)Exterior Case Galvanized sheet steelColor RAL7032 beige powder finishNEMA Rating Enclosures IP 54/NEMA 12
Technical Data
Electrical Data DTS3500A115 DTS3500A230
Rated Voltage 115 V 60 Hz 230V 50/60 Hz100 V 50 Hz
Range of Operation 103-127 V 207-253VPower Consumption 590 W 420WRunning Amps 6.7 A 2.9 AStarting Current 17.5 A 8.3 ALine Cord With plug Without plug
Drilling TemplateNote: Any unmarked radius is ø 0.79"R
SideView
Front View
DescriptionCompact design for side mountingon any enclosure surface where hotspot or low capacity cooling isrequired.Closed loop cooling ensures cleanenclosure air is recirculated without evermixing with contaminated ambient air.
StandardsMaintains enclosure's NEMA 12 ratingIP 54UR, cUR and CE
FeaturesR134a refrigerant.Thermostat control.Expansion valve increases efficiencywith improved evaporator heattransfer and less frequent compressoroperation.Built in condensate evaporator.Continuous air circulation from highcapacity fans.
Side Mounting DTS Series3500 BTU/H
EMI/RFI suppression meets CE.Line cord with plug (230 V).Volt free N/O (normally open) contactfor high pressure failure indication.Door contact for power down whenenclosure door is opened.Washable filter mat protected withinan easily removable grill.Gasket, mounting kit and templatefor cutout and drilling are included.Condensate drain hose and clamp.Exterior case easily removable forresetting thermostat and field service.Q Mount allows unit to hang in placefor easy installation.
AccessoriesGaskets...see page 356Lifting lugs...see page 356Remote door switch...see page 356Replacement filters...see page 356Replacement grill...see page 356
Air C
on
ditio
ners
Quality Enclosures. Service Excellence. © Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
352
Clim
ate Con
trol P
rod
ucts
Air C
on
ditio
ners
Part Number Ship Wt. lbs.
DTS6000A115 106
DTS6000A230 106DTS8000A115 189
DTS8000A230 189DTS12000A115 189
DTS12000A230 189
Side Mounting DTS Series6000, 8000 & 12000 BTU/H
DescriptionDesigned for side mounting on anyenclosure surface where highcapacity system cooling is required.Closed loop cooling ensures cleanenclosure air is recirculated withoutever mixing with contaminatedambient air.Optimum air circulation withmaximum clearance distancebetween warm inlet and cold outletfor reduced hot spot locations.
StandardsMaintains enclosure's NEMA 12 ratingIP 54UR, cUR and CE
FeaturesR134a refrigerant.Thermostat control.Hot gas bypass valve preventsevaporator freeze up whileminimizing heavy inrush currents onlarge BTU/H units.Built in condensate evaporator.Continuous air circulation from highcapacity fans.EMI/RFI suppression meets CE.Line cord included - see chart fordetail.Volt free N/O (normally open)contact for high pressure failureindication.Provision for door contact allowingpower down when enclosure door isopened.Gasket, mounting kit and templatefor enclosure cutout and drilling areincluded.
Washable filter mat protected withinan easily removable grill.Condensate drain hose and clampprovided.Exterior case easily removable forresetting of thermostat and otherfield service.Versatile design maintains foot printfor larger capacity units if required.Q Mount allows unit to hang in placefor easy installation.
AccessoriesGaskets...see page 356Lifting lugs...see page 356Recessed mounting frame...see page 356Remote door switch...see page 356Replacement filters...see page 356Replacement grill...see page 356
Technical Data
Electrical Data DTS6000A115/ DTS8000A115/DTS12000A115/DTS6000A230 DTS8000A230/DTS12000A230
Rated Voltage 115 V 60 Hz/ 115 V 60 Hz/230 V 50/60 Hz 230 V 50/60 Hz
Range of Operation 103-127 V/187-253 V 103-127 V/187-253 VPower Consumption 1,100 W/810 W 2,100 W/1,800 W
Running Amps 13.4 A/4.3 A 21.0 A/12.5 AStarting Current 26.8 A/16.5 A 52.0 A/46.2 A
Line Cord Terminal Block Terminal Block
6000 BTU/H unit shown
Quality Enclosures. Service Excellence.© Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
353
Clim
ate Con
trol Pro
du
cts
Side Mounting DTS Series6000, 8000 & 12000 BTU/H
Drilling TemplateDTS6000, DTS8000 &
DTS12000Note: Any unmarked radius is ø 0.79"R
Side ViewDTS8000 &DTS12000
Front ViewDTS8000 &DTS12000
Refrigeration Data DTS6000A115/DTS6000A230 DTS8000A115/DTS8000A230 DTS12000A115/DTS12000A230
Rated Capacity 6,000 BTU/H (1,740 Watts) 8,000 BTU/H (2,320 Watts) 12,000 BTU/H (3,500 Watts)
Type of Refrigeration R134a R134a R134aRefrigerant Charge 530 g 790 g 790 g
Adjustable Thermostat Factory setting +95°F (+35°C) Factory setting +95°F (+35°C) Factory setting +95°F (+35°C)Max. Ambient Air Temp. +125°F (+52°C) +125°F (+52°C) +125°F (+52°C)
Min. Ambient Air Temp. +46°F (+8°C) +46°F (+8°C) +46°F (+8°C)Air Capacity (unrestricted) Internal Circulation 247 CFM Internal Circulation 506 CFM Internal Circulation 542 CFM
External Circulation 565 CFM External Circulation 542 CFM External Circulation 542 CFM
Condensate Discharge Condensate evaporator Condensate evaporator Condensate evaporatorFilter Mat 150 g/m² 150 g/m² 150 g/m2
Db Noise Level < 64 dB(A) < 65 dB(A) < 65 dB(A)Unit Weight 101 lbs (46 kg) 180 lbs (82 kg) 180 lbs (82 kg)
Exterior Case Galvanized sheet steel Galvanized sheet steel Galvanized sheet steelColor RAL7032 beige powder finish RAL7032 beige powder finish RAL 7032 beige powder finish
NEMA Rating Enclosures IP 54/NEMA 12 Enclosures IP 54/NEMA 12 Enclosures IP 54/NEMA 12
Side ViewDTS6000
Front ViewDTS6000 A
ir Co
nd
ition
ers
Quality Enclosures. Service Excellence. © Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
354
Clim
ate Con
trol P
rod
ucts
Drilling Template
Top View Side View
Drilling for cabinets with 15.75" depth only.
Part Number Ship Wt. lbs.
DTT4500A115 95
DTT4500A230 95
Top Mounting DTT Series4500 BTU/H
DescriptionDesigned for top mounting wherespace limitations do not allow sidemounting on the enclosure surface.Closed loop cooling ensures cleanenclosure air is recirculated without evermixing with contaminated ambient air.
Gasket, mounting kit and templatefor cutout and drilling are included.Condensate drain hose and clamp.Volt free contact for high pressurefailure.Exterior case easily removable forresetting thermostat and fieldservice.Can accommodate crane hooks toassist installation.Versatile design maintains foot printthrough the series.
AccessoriesGaskets...see page 356Lifting lugs...see page 356Remote door switch...see page 356Replacement filters...see page 356Replacement grill...see page 356
Refrigeration Data
Rated Capacity 4,500 BTU/H (1,300 Watts)
Type of Refrigerant R134aRefrigerant Charge 480 g
Adjustable Thermostat Factory setting +95°F (+35°C)Max. Ambient Air Temp. +125°F (+52°C)
Min. Ambient Air Temp. +46°F (+8°C)Air Capacity (unrestricted) Internal Circulation 547 CFM
External Circulation 547 CFM
Condensate Discharge Condensate evaporatorFilter Mat 150 g/m²
Db Noise Level < 66 dB(A)Unit Weight 90 lbs (41 kg)
Exterior Case Galvanized sheet steelColor RAL7032 beige powder finish
NEMA Rating Enclosures IP 54/NEMA 12
Technical Data
Electrical Data DTT4500A115 DTT4500A230
Rated Voltage 115 V 60 Hz 230V 50/60 Hz100 V 50 Hz
Range of Operation 103-127 V 207-253 VPower Consumption 630 W 840 W
Running Amps 7.7 A 5.2 AStarting Current 24.9 A 18.5 A
Line Cord With plug Without plug
StandardsMaintains enclosure's NEMA 12ratingIP 54UR, cUR, CE
FeaturesR134a refrigerant.Thermostat control.Expansion valve increases efficiencywith improved evaporator heattransfer and less frequentcompressor operation.Built in condensate evaporator.Continuous air circulation from highcapacity fans.EMI/RFI suppression meets CE.Line cord with plug (115 V).Washable filter mat protected withinan easily removable grill.
Air C
on
ditio
ners
Quality Enclosures. Service Excellence.© Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
355
Clim
ate Con
trol Pro
du
cts
Side Mounting DTS Series - NEMA 3R, 4, 4X2000 BTU/H
DescriptionCompact design for side mountingon any enclosure surface where spotcooling or low capacity cooling isrequired.Closed loop cooling ensures cleanenclosure air is recirculated withoutever mixing with contaminatedambient air.Ideal for outdoor or very wet conditions.
StandardsUR, cUR, and CEComplies with
NEMA 3R, 4, 4X
FeaturesStainless steel body.R134a refrigerant.Thermostat control.
Line cord with plug (115 V).Aluminum filter provides easyaccess cleaning.Expansion valve permits increasedefficiency through improvedevaporator heat transfer and lessfrequent compressor operation.Built in condensate evaporator.Continuous air circulation from highcapacity fans.EMI/RFI suppression meets CEstandard.Gasket, mounting kit, and templatefor cutout and drilling are included.Condensate drain hose and clamp.Q Mount allows unit to hang in placefor easy installation.
Drilling Template Side View Top View
Refrigeration Data
Rated Capacity 2,000 BTU/H (580 Watts)
Type of Refrigerant R134aRefrigerant Charge 300 g
Adjustable Thermostat Factory setting +95°F (+35°C)Max. Ambient Air Temp. +125°F (+52°C)
Min. Ambient Air Temp. +46°F (+8°C)Air Capacity (unrestricted) Internal Circulation 230 CFM
External Circulation 230 CFM
Condensate Discharge Condensate evaporatorFilter Mat Aluminum metal mesh
Db Noise Level < 62 dB(A)Unit Weight 72 lbs (33 kg)
Exterior Case 304 Stainless steelFinish Polish #3
NEMA Rating 3R, 4, 4X
Part Number Ship Wt. lbs.
DTS2000A115N4SS 75
DTS2000A230N4SS 75
Technical Data
Electrical Data DTS2000A115N4SS DTS2000A230N4SS
Rated Voltage 115 V 60 Hz 230 V 50/60 Hz110 V 50 Hz
Range of Operation 103-127 V 198-253 VPower Consumption 230 W 170 W
Running Amps 2.9 A 1.3 AStarting Current 13.8 A 7.4 A
Line Cord With plug Without plug
Air C
on
ditio
ners
Quality Enclosures. Service Excellence. © Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
356
Clim
ate Con
trol P
rod
ucts
Part No. 1481DJ10
Neoprene Gasket KitReplacement for standard supplied gasket.Self-adhesive cellular neoprene gasket.Supplied in 10 foot rolls, 0.19"x0.75".For side mount units greater than 3500 BTU/H,two gasket kits are required.
Recessed Mounting FrameRecessed mounting frame assemblyaccepts 3 different capacity side mountunits from 6,000 to 12,000 BTU/H.Allows units to be recessed by 5.5"(140 mm) into the cabinet.Gasket , mounting kit and templatecutout included.Finished in beige.
Air Conditioner Accessories
Part No. DTSRF61
Replacement FiltersPackaged in quantities of 5.Made of synthetic fibers.Re-usable up to 20 times.100% resistant to humidity.Filters have a mass filtering level of67%.
Dimensions Use With Filter DensityPart No. A B Air Conditioner (g/m2)
DTSF3150 inch 8.30 8.30 DTS1200 - DTS6000 150mm 210 210
DTSF5150 inch 11.00 11.00 DTS8000 - DTS12000 150mm 280 280
DTTF5150 inch 11.81 11.81 DTT4500 150mm 300 300
Remote Door SwitchPermits convenient door activated on-off function of airconditioners. Mounts to flange of any Hammondenclosure.Can be wired normally open or normally closed.115/230 V AC
Part No. FLKDS
Replacement GrillReplacement grill for air conditioners.Packaged individually.
Black RAL7032 Beige Use WithPart No. Part No. Air Conditioner
PG3BK PG3RAL DTS1200 - DTS6000
PG5BK PG5RAL DTS8000 - DTS12000n/a AFF1 DTT4500
Lifting LugsPackaged in quantities of 2.Used for lifting, transporting and installation of airconditioners.8 mm diameter.For use with DTS3500 - DTS12000 and DTT4500.
Part No. LL8A
ir Co
nd
ition
ers
Quality Enclosures. Service Excellence.© Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
357
Clim
ate Con
trol Pro
du
ctsA
ir Co
nd
ition
ers
Quality Enclosures. Service Excellence. © Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
358
Clim
ate Con
trol P
rod
ucts
Blowers and FansGeneral Selection Considerations
General SpecificationsAll Hammond blowers and filter fans are engineered for performance and built for reliability. This versatile line includes ablower, fan tray and filter fans.Blowers and fans use forced convection cooling, which means ambient air flows through a filter into the enclosure to coolheated components. Both blowers and fans are sized in CFM (cubic feet per minute).It is recommended that an exhaust filter be used in combination with the blower or filter fan to act both as an exhaust point forthe hot internal air plus aid in the pressurization of the enclosure, reducing the chance of unfiltered air entering theenclosure. Whenever possible, the blower or filter fan should be located in the bottom third of the enclosure and the filteredexhaust grill placed as high as possible on the opposing side. Performance levels can be further increased by adding asecond exhaust filter.
Sizing Blowers and FansTo determine the CFM (cubic feet per minute) required in any standard situation, use the following calculation,(non-standard situations would consist of high air density - significantly more than 0.075 lbs per cubic foot.)
CFM =
CFM x (0.075)
Non-standard Air Density (lbs per cubic foot)
Note - The calculation above is exact, but adding an additional 25% to the CFM level is a standard safety factor.
If the air density is high (significantly more than 0.075 lbs per cubic foot), use the number calculated above in the followingformula:
Power to be dissipated (Watts) x 3.17
Maximum Allowable Internal Temperature (°F) - Maximum Ambient Temperature (°F)
Note: Ambient Temperature must be lower than maximum internal temperature for fan/blower to be effective.
Blo
wers
Quality Enclosures. Service Excellence.© Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
359
Clim
ate Con
trol Pro
du
cts
Packaged Twin Blowers160 to 470 CFM
DescriptionEach contains a quadruplexcentrifugal blower powered by asingle precision ball-bearing motor.These widely-used Packaged TwinBlowers deliver air from more than50% of their 17" width.Internal neoprene isolation mountsreduce transmission of vibration tothe enclosure.Can be mounted on panel rails orinto a cutout in an enclosure.
FeaturesCapacities: 160 to 470 CFM.Heavy-gauge steel enclosures withEIA-notched flanges for railmounting.Attractive 19 inch stainless steelgrills.UR/CSA approved ball-bearingmotors.Inlet air cools motor for longer life.Permanent filters.Exhaust guards included.Six foot (minimum) SJTW 3-wirecord.
AccessoriesReplacement filters...see page 362Filter coat...see page 367
Free Flow Air RPM Ambient Temp. Panel Ht. ShipPart No. Delivery(CFM)Nominal Min. F Max. F Units E F G H J K L M N Wt.lbs
KP350A 160 1500 -20 250 2 3.50 8.75 10.50 - 7.50 - 2.25 2.25 - 10
KP529A 300 3000 -20 250 3 5.25 6.25 7.69 4.50 4.50 0.63 1.88 3.00 1.19 18KP729A 470 3250 -20 250 4 7.00 8.25 10.25 4.63 4.75 1.00 2.50 4.00 1.44 23
KP729A
50 Hz60 Hz
KP350A
Air Flow C.F.M.
Sta
tic P
ress
ure
Air Flow C.F.M.
Sta
tic P
ress
ure
KP529A
Air Flow C.F.M.
Sta
tic P
ress
ure
KP529A& KP729AKP350A
Blow
ers
Quality Enclosures. Service Excellence. © Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
360
Clim
ate Con
trol P
rod
ucts
PF Filter Fans
DescriptionThis line of fans provides innovativetechnology for fan cooling andpressurizing of industrial cabinets. Ahigh quality filter fan provides aneconomical method of ensuring yourenclosure does not overheat.Filtered passive ventilation can beprovided by an exhaust filter foreither convection cooling or incombination with a fan in forced aircooling.The slim-line design of this fan lineis unique, when installed, the frontlouvered grill protrudes less thanone quarter inch. The attractive grillmaintains the sleek aesthetics of anenclosure system.
StandardsUR, CUR and CE.Built to IP54 standards (exceptPF1000/PFA1000 - IP43 standards).Maintains NEMA 12 integrity ofenclosure
FeaturesAvailable in 115V and 230VversionsHigh performance fan motors withfinger guards.ABS-FR grills (except PF1000Series which is polystyrene FR).Durable, reusable filter mat.Grills are black allowing for acomplementary match to all cabinetcolors.Integral gasket to seal againstenclosure. (except PF1000 - usePFG1000)
Free Flow Air Delivery Max. Static Filter Sound AmbientAir Delivery w/Exhaust Pressure Density Filtering Level Connector Temp. °F Comparable Ship
Part No. Voltage (CFM) (CFM) (Pa) (g/m2) Level (dB) Type Max/Min IP Standard Wt. lbs
PF1000 115 16 10 29 150 73% 39 2 - 12" wires 140/14 IP43 3
PF2000 115 38 28 69 150 73% 49 terminal strip 122/14 IP54 5PF2500 115 89 62 57 150 73% 55 terminal strip 122/14 IP54 7
PF3000 115 169 142 89 150 73% 55 terminal strip 122/14 IP54 10PF5000 115 324 249 205 150 73% 69 terminal strip 122/14 IP54 15
PF6000 115 410 295 225 150 73% 71 terminal strip 122/14 IP54 15PF1000230 230 16 10 29 150 73% 39 2 - 12" wires 140/14 IP43 3PF2000230 230 38 28 69 150 73% 49 terminal strip 122/14 IP54 5PF2500230 230 89 62 57 150 73% 55 terminal strip 122/14 IP54 7PF3000230 230 169 142 89 150 73% 55 terminal strip 122/14 IP54 10PF5000230 230 324 249 205 150 73% 69 terminal strip 122/14 IP54 15PF6000230 230 410 295 225 150 73% 71 terminal strip 122/14 IP54 15
Easy InstallationThe patented "Click and Fit" systemallows for rapid filter fan and exhaustfilter installation without screws.After using the convenient cutouttemplate (provided with every unit),the fan and/or exhaust filter justsnaps into the opening.
AccessoriesExhaust filters...see page 362Replacement grills...see page 362Replacement filters...see page 362
PF3000 and PF2000
Filter Fans
Quality Enclosures. Service Excellence.© Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
361
Clim
ate Con
trol Pro
du
cts
PF Filter Fans
PF1000 PF2000
PF3000PF2500
PF5000 PF6000
PFA3000 PFA5000
PFA1000 PFA2000
Filter Fans
Note: All cutout tolerances +1/- 0 mm
Quality Enclosures. Service Excellence. © Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
362
Clim
ate Con
trol P
rod
ucts
Filters/Fans
Replacement FiltersPackaged in quantities of 5.Made of self-extinguishing syntheticfibers.
Dimensions Use With Filter DensityPart No. A B Filter Fan (g/m2)
PFF1000 inch 3.40 3.40 PF1000 150mm 85 85
PFF2000 inch 4.50 4.50 PF2000 350mm 115 115
PFF3000 inch 8.30 8.30 PF2500/PF3000 350mm 210 210
PFF5000 inch 11.00 11.00 PF5000/PF6000 350mm 280 280
Fan Accessories
Filter Density FilteringComparablePart No. (g/m2) Level IP Standard
PFA1000 150 73% IP43
PFA2000 150 73% IP54PFA3000 150 73% IP54
PFA5000 150 73% IP54
Exhaust FiltersBuilt to IP54 standards (exceptPFA1000 - IP43 standards).ABS-FR grills (except PF1000Series which is polystyrene FR).Self-extinguishing, re-usable filtermat.Grills are black to complement allcabinet colors.Grills also available (see below)Integral gasket seals againstenclosure.
Replacement GrillPackaged individually.Consists of replacement grill only.
Black RAL7032 Beige Use With Use WithPart No. Part No. Filter Fan Exhaust Filter
PG1BK PG1RAL PF1000 PFA1000
PG2BK PG2RAL PF2000 PFA2000PG3BK PG3RAL PF2500/PF3000 PFA3000
PG5BK PG5RAL PF5000/PF6000 PFA5000
Quality Enclosures. Service Excellence.© Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
363
Clim
ate Con
trol Pro
du
ctsTo
p M
ou
nt Fan
Top Mount FanMounts to top of enclosure.Ideal for use with IME Series (notcompatible with 400mm deep IMETcabinets).470 CFM free flow, 375 CFM usingPFA6000 as inlet.115V 50/60HzTerminal block connection.20.9" x 13.8" x 4.3"HUL/cUL Approved.Gasket seal- IP33 ingress protectionlevel.Finished in RAL7032 beige.
Part No. PTF8000
Top Mount Fan
Cutout Template(dimensions in mm)
Intergral Door Air ConditionersAir/Water Heat ExchangersCustom Air/Air Heat ExchangersEMC Filter Fansother customer cooling solutionsthrough our knowlegeablePfannenberg experts
Call Hammond for other Cooling Solutions....
Quality Enclosures. Service Excellence. © Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
364
Clim
ate Con
trol P
rod
ucts
Fan Kits
Part No. Size(mm) Size (In.) CFM AC Voltage Use Fan Guard Use Filter Fan Grill
FAN80AC115 80 3.15 32 115 FAN80FG XPFA80...1
FAN80AC230 80 3.15 32 230 FAN80FG XPFA80...1
DNMF100AC115 120 4.70 100 115 DNFG XPFA120...1
DNMF100AC230 120 4.70 100 230 DNFG XPFA120...1
FAN150AC115 150 6.00 210 115 FAN150FG n/aFAN150AC230 150 6.00 210 230 FAN150FG n/aFAN10A115 255 10.00 550 115 FAN10FG n/aFAN10A220 255 10.00 550 230 FAN10FG n/a1"..." specify color - BK (black), CG (RAL 7032) or GY (ASA61 gray)
Fan Cords and Daisy Chains (10 amp, 115V)
Lead Fan EndPart No. Description Length (In) Connector Termination
DNMFC Fan Cord 24" Straight noneDNFC48P Fan Cord 48" 45° 2 pin 115V plugDNFC72P Fan Cord 72" 45° 2 pin 115V plugDNFCDC2P Daisy Chain 24" 2x45°, 24" apart 2 pin 115V plugDNFCDC3P Daisy Chain 24" 3x45°, 24" apart 2 pin 115V plug
AC Fans and Guards
Filter Fan GrillsMounts easily with 4 screws usingthe template provided.All mounting hardware included.Standard 80mm/3.15" and 120mm/4.00" fans can be attached withhardware provided to make a filter fan.Can be used alone as an enclosureexhaust.Moulded in flame retardant ABS.Flame retardant synthetic filtersupplied.Integral gasket on reverse of grillseals against enclosure surface.Available in black, RAL7032 beigeand ASA61/RAL7011 gray to matchenclosures.
Black Beige Gray Optional Compatible Fan Repl.Part No. Part No. Part No. H W Part No. Size CFM Filter (pkg. 5)
XPFA80BK XPFA80CG XPFA80GY 4.13 4.13 FAN80AC115 80mm/3.15" 32 PFF1000XPFA120BK XPFA120CG XPFA120GY 5.91 5.91 DNMF100AC115 120mm/4.70" 102 PFF2000
AccessoriesSpare hardware kit, Part No. 1421F4
Filterfs/Fans
Quality Enclosures. Service Excellence.© Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
365
Clim
ate Con
trol Pro
du
cts
Fan PanelsCreate your own rack mountfan or filter fan from these panels.Black powder coated steel.Also available in 24" and otherwidths or custom configurations.Fans sold separately...see page364.
Punched 19" Fan Panels
Optional Optional Optional OptionalCutouts for Fan Fan Guard Filter Grill Replacement
Part No. Panel Size Stnd. Fans # Holes Part No. (115V) Grill (Black) Filter (pkg. 5)
PPFP190802BK1 3U 80mm/3.15" 2 FAN80AC115 FAN80FG XPFA80BK PFF1000
PPFP190803BK1 3U 80mm/3.15" 3 FAN80AC115 FAN80FG XPFA80BK PFF1000PPFP191202BK1 4U 120mm/4.70" 2 DNMF100AC115 DNFG XPFA120BK PFF2000
Punched 19" Grill Panels (with integral front finger guard)
PPGP191202BK1 3U 120mm/4.70" 2 DNMF100AC115 DNFG - -
19" Fan Panel
19" Grill Panel
Fan Kits
Filterfs/Fans
Quality Enclosures. Service Excellence. © Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
366
Clim
ate Con
trol P
rod
ucts
Filter FansFiltered Fan Boxes and Filter Grills
Features115 VAC or 230 VAC, 50/60 Hz.6 foot lead wires.Exceptionally quiet operation.Versatile mounting and adaptability.Heavy-gauge steel construction.Attractive stainless steel grills.Shipped with air flow to pressurize.Can be user modified to exhaust.Aluminum filter is coated withadhesive baffle surfaces for dust anddirt collection. Can be recoated aftercleaning for optimum performance.Drilling template included.NOTE: One grill and filter areincluded with each fan package.Normally, an additional exhaust grilland filter are required for eachinstallation and must be orderedseparately.
AccessoriesFilter coat...see page 367Replacement Filter...see page 367
DescriptionIn a typical cooling arrangement, thefiltered fan box pulls air into theenclosures and the filter grill is usedas an air outlet.The washable aluminum filter grilland the air filter are easily accessibleand can be removed for cleaning.The filtered fan boxes are available ineither 115 VAC or 230 VAC, 50/60 Hz.Filtered passive ventilation can beprovided by an exhaust filter foreither convection cooling or incombination with a fan in forced aircooling.
StandardsUR/CUR/CE approved fan motors.
Filter GrillFiltered Fan Box
Filter Fans
Quality Enclosures. Service Excellence.© Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
367
Clim
ate Con
trol Pro
du
cts
Cutout Detail
Filtered Fan BoxesFree Flow
Air Delivery RPM Running ShipPart No. CFM Volts Nominal Amps Watts A B C D D1 E F G H Wt. lbs
XF4115 105 115 3000 0.18 15 6.13 7.38 2.38 5.63 5.75 6.38 4.13 0.78 7.0 5
XF4230 105 230 3000 0.09 15 6.13 7.38 2.38 5.63 5.75 6.38 4.13 0.78 7.0 5XF6115 220 115 3300 0.29 33 7.63 8.88 3.00 7.13 7.25 7.88 4.50 1.34 8.5 6
XF6230 220 230 3300 0.15 33 7.63 8.88 3.00 7.13 7.25 7.88 4.50 1.34 8.5 6XF10115 560 115 1600 0.87 60 11.63 13.00 4.56 11.13 11.25 11.88 6.88 2.16 12.5 12
XF10230 560 230 1600 0.45 60 11.63 13.00 4.56 11.13 11.25 11.88 6.88 2.16 12.5 12
Exhaust Grill and FiltersPart No A B D E1 F1 H1
XFG4 6.13 7.38 5.63 6.38 4.13 7.00
XFG6 7.63 8.88 7.13 7.88 4.50 8.50XFG10 11.63 13.00 11.13 11.88 6.88 12.501 Dimension for mounting and cabinet cutout. Secure sheet metal with #8 hardware.
Part No. 1475Q
Filter CoatProvides a filter adhesive with agrease-like consistency whichabsorbs and traps dust particles.10 oz. bottle with environmentallyfriendly trigger spray.
Filter FansFiltered Fan Boxes and Filter Grills
Filter Fans
Part No Pkg. Qty.
XFF4 3
XFF6 3XFF10 3
Replacement Filters
Quality Enclosures. Service Excellence. © Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
368
Clim
ate Con
trol P
rod
ucts
Heatin
g P
rod
ucts
Fan Tray300, 600 and 900 CFM
Without With LightedSwitch Switch Running Panel Case Case Rear Bracket DepthPart No. Part No. CFM Amps Watts Width Width Depth Min. Max.
FT300TA1BK FT300HA1BK 300 0.5 40 19 17.00 7.50 n/a n/a
FT600TA1BK FT600HA1BK 600 1.0 80 19 17.00 13.00 2.40 19.20FT900TA1BK FT900HA1BK 900 1.5 120 19 17.00 18.50 7.90 24.70
ApplicationRack mount fan trays provide acompact, economical solution forcooling in electronic cabinets.Fan trays can be positioned at thebottom of an enclosure to force airthrough the cabinet, at the top toexhaust air out of the cabinet orbelow specific pieces of equipmentfor spot cooling.
StandardsUR/CUR listed
Features300, 600 and 900 CFM sizes.115VAC, 50/60Hz.19" panel width mounting.Low profile 1.75" (1U) height.600 and 900 CFM units includeremovable rear support brackets.Circuit breaker protected.6 foot 14/3 SJTW cord with molded3 prong plug.
Thermally protected, ball bearingfans.Integral finger guards above andbelow fans.Shipped fully assembled.Available with or without ON/OFFswitch.
FinishStocked in textured, black bodyfinish.Textured black face panel.
OptionsContact Hammond for informationon:
24" panel width mounting.230 V version (without plug).15 foot cordOptional colors
FT600HA1BK
FT300HA1BK
FT900HA1BK
Note: All cad drawings are shown withoptional lighted switch. All units are also
available without switch - see chart below.
Quality Enclosures. Service Excellence.© Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
369
Clim
ate Con
trol Pro
du
ctsH
eating
Pro
du
cts
Heating ProductsGeneral Information and Sizing
General InformationHeating products protect electronic and electrical components from temperature problems that are below acceptabletolerances. There are obvious circumstances when extremely low ambient (outside cabinet) temperatures would require aheater, but there are also less apparent times that a heater should be considered. For example, a system may run all dayhaving its components generate heat, but once the system shuts down for the night, the quick drop in temperature couldcause condensation and possibly corrosion - a heater could maintain a safe, constant temperature.
Combined Cooling and HeatingSome components today are sensitive enough that both cooling and heating could be required in the same enclosure. Whendesigning your system, be aware of the need to maintain a relatively constant temperature inside the enclosure as ambienttemperatures swing from cool to very hot. Hammond thermostats (one for heaters and one for cooling products) can controlboth systems automatically.
Heater Sizing Information
PH = Total power required for this application (W)PV = Existing power from components (W)DT = Temperature differential (Kelvin) ambient to
cabinet interior (1°Kelvin = 1°C = 1.8°F)A = Free-standing cabinet surface area (ft2)k = Heat transmission coefficient (W/ft2 K) convection
in quiet air:Painted steel approx. 0.51 W/ft2 KAluminum approx. 1.115 W/ft2 KPlastic approx. 0.325 W/ft2
Stainless Steel approx. .344 W/ft2 K
FormulaPH = (DT x k x A) - PV
If enclosure located outside, use x2 (DT x k x A)
Sample with solution:DT = 5Kk = Painted steel = 0.51 W/ft2
A = 50 ft2
PV = 50 WPH = (5 x 0.51 x 50) - 50
= 127.5 - 50= 77.5 W
Recommend: SHP045039, 80WHeater
Quality Enclosures. Service Excellence. © Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
370
Clim
ate Con
trol P
rod
ucts
Heatin
g P
rod
ucts
HeatersDesigned to provide enclosed electronic, pneumatic,hydraulic and mechanical equipment with protection fromlow temperatures, condensation and corrosion.The PTC (Positive Temperature Coefficient) heater unitmaintains a stable temperature environment withinenclosures, allowing critical components to perform withconsistent reliability for longer periods.Thermostats are also available...see page 374.
Surface Starting Dimensions ShipPart No. Watts Temperature Current Length x Width x Depth Wt. lbs
SHP045009 15 W 149°F 0.6 A 2.6 x 2.8 x 2.0 1
SHP045019 30 W 167°F 1.2 A 2.6 x 2.8 x 2.0 1SHP045029 50 W 194°F 1.5 A 5.5 x 2.8 x 2.0 1
SHP045039 80 W 203°F 2.0 A 8.7 x 2.8 x 2.0 2SHP045049 100 W 212°F 3.0 A 8.7 x 2.8 x 2.0 2
Operating Voltage: AC 110-120 V, 50/60 Hz
Heating Element: PTCHeating Body: Extruded aluminum, black anodized
Connection: SJT 3X18 AWG, 20" lengthMounting: Easily installed by clip mounting on 35 mm DIN rails (included)
Protection Class: 1 (tested for grounding at 1250 V)Protection: IP54
Approval: UL Recognized Component, cUL Recognized Component, CE
Fan HeatersFor use when larger heating capacities or internal forcedair circulation is required.Designed to prevent condensation or maintain minimumtemperature in enclosures.Thermostats are also available...see page 374.
Surface Starting Dimensions ShipPart No. Watts Temperature Current Length x Width x Depth Wt. lbs
SHGL04600 250 W 167°F 2.2 A 7.00 x 3.15 x 3.15 2SHGL04601 400 W 167°F 3.5 A 9.76 x 3.15 x 3.15 3
Operating Voltage: AC 110-120 V, 50/60 Hz
Circulation Power: 20 CFM Free BlowingAxial Fan: Ball bearing
Durability: 30,000 hrs. at 68°F ambient temperatureHeating Element: Resistance heating element with termperature limiter
Heating Body: Extruded aluminum, black anodizedConnection: 3 pole terminal for 12 AWG
Mounting: Easily installed by clip mounting on 35 mm DIN rails (included)Protection Class: 1 (tested for grounding at 1250 V)
Protection: IP20Approval: UL Recognized Component, cUL Recognized Component, CE
Heating Products
Quality Enclosures. Service Excellence.© Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
371
Clim
ate Con
trol Pro
du
cts
Control Panel HeaterWhen larger heating capacities or internal forced aircirculation is required and space is limited.Compact design to prevent condensation or maintainminimum temperature in enclosures.Fan is included.Thermostats available...see page 374.
Operating Temperature Maximum ShipPart No. Watts Current (Amps) Volts with Fan Wt. lbs
SHV031029 100 W 0.89 AC 120 250°F/120°C 1
SHV031039 150 W 1.30 AC 120 320°F/160°C 1SHV031139 200 W 1.79 AC 120 250°F/120°C 1
SHV031149 300 W 2.62 AC 120 320°F/160°C 1SHV031159 400 W 3.45 AC 120 360°F/180°C 1
Operating Voltage: AC 110 -120 V 50/60 Hz
Air Flow: 20 CFM (100W, 150W heaters), 63 CFM (200W, 300W, 400W heaters)Axial Fan: Ball bearing
Durability: 30,000 hrs. at 68°F ambient temperatureHeating Element: Cartridge heater
Heating Body: Die cast aluminumConnection: 5 pole terminal for 14 AWG (maximum)
G/L1/N1: HeaterL2/N2: FanMounting: Easily installed by clip mounting on 35 mm DIN rails (included)
Protection class: 1 (tested for grounding at 1250 V)Protection: IP44Approval: UL Recognized Component, cUL Recognized Component,CE
200 W, 300 W, 400 W Heaters
100 W, 150 W Heaters
Heating Products
Heatin
g P
rod
ucts
Quality Enclosures. Service Excellence. © Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
372
Clim
ate Con
trol P
rod
ucts
Heatin
g P
rod
ucts
High Wattage Fan HeaterFor large heating capacity requirements.Maintains minimum operating temperatures inenclosures.Helps prevent failures to components caused bycondensation and corrosion.Built-in thermostat and control light.Heating power adjusts to ambient temperature.Heat exits top of fan heater. (add 2" clearance for heatsensitive parts)
Inrush Temperature Maximum ShipPart No. Watts Current (Amps) Volts with Fan Wt. lbs
SCR027009 550 W 11 A AC 120 250°F/120°C 2
SCR027019 650 W 12 A AC 120 320°F/160°C 2.4
Air Flow: 20 CFM (550W), 26 CFM (650W)Thermostat Range: 32 - 140 degrees Fahrenheit
Heating Element: PTC - Semiconductor/resistorHousing: Plastic, rated UL94-VO
Connection: 3 pole terminal, AWG 14 max (2.5 mm2)Mounting: Clip for 35mm DIN rail
Protection Class: II (Double Insulated)Protection Type: IP20
Approval: UL Recognized Component, cUL Recognized Component, CE
Heating Products
Quality Enclosures. Service Excellence.© Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
373
Clim
ate Con
trol Pro
du
cts
DimensionsPart No. Height x Width x Depth Switching Capacity
SKTH012009 2.64 x 1.97 x 1.54 AC 8 A @ 115 VDC 0.5 A @ 100 VDC 8 A @ 12 VDC 5 A @ 35 V
Temperature Range: 32°F to 140°F (0°C to 60°C)
Switching difference (hysteresis): Approximately 3.6°F (2°K)Humidity range: 50% to 90% relative humidity
Response time : Approximately 160 secondsFunction Indication: LED
Life expectancy: 100,000 cyclesMounting : Easily installed by clip mounting on 35mm DIN rail
Housing : Flame retardant plastic UL94VOColor: Gray
Protection: IP20Approval: UL Recognized Component, cUL Recognized Component, CE
Electronic Humidity and Temperature ControlDesigned to provide both air temperature and humiditycontrol as well as monitoring in electrical and electronicenclosures.Independently senses the relative humidity andtemperature. Resistive and inductive loads (heaters orfilter fans) can be switched.Highly effective in ATMs, parking control gates, ticketdispensers and traffic control systems where equipment isexposed to wide ranging outdoor elements.
Heating Products
Front View Side View
Bottom View
Co
ntro
l Devices
Quality Enclosures. Service Excellence. © Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
374
Clim
ate Con
trol P
rod
ucts
ThermostatDesigned to provide air temperaturecontrol and monitoring in cabinets.Thermostat NC (Normally Closed) forthe control of heaters and heater fans.Thermostat NO (Normally Open) forthe control of cooling units, or forswitching signal transmitters in case ofoverheating.Available in Fahrenheit or Celsius.
Contact Dimensions Switching ShipPart No. Scale Type Height x Width x Depth Capacity Wt. lbs
SKT011409NC °F Normally Closed 2.4 x 1.3 x 1.4 15 A (1) AC 120 V, 10 A (1) AC 250 V 1SKT011409NC-C °C Normally Closed 2.4 x 1.3 x 1.4 15 A (1) AC 120 V, 10 A (1) AC 250 V 1
SKT011419NO °F Normally Open 2.4 x 1.3 x 1.4 15 A (1) AC 120 V, 10 A (1) AC 250 V 1SKT011419NO-C °C Normally Open 2.4 x 1.3 x 1.4 15 A (1) AC 120 V, 10 A (1) AC 250 V 1
Heating Products
Sensor Element: Thermostatic bi-metal
Switching difference (hysteresis): ±4°F (±3°K)Adjustment Range: 30-140°F
Noise Suppression: "N" (according to VDE 0875)Connection: 2 pole terminal for AWG 14 (2.5mm2)
Mounting: Easily installed by clip mounting on 35 mm or 38 mm DINrails (included)
Housing: Flame retardant plastic UL94VO
Color: Gray (SB)Protection: IP30
Approval: UL Recognized Component , cUL Recognized Component, CE
Breather Kit (Pressure Compensation Plug)
Mounting: PG 29 (1.14") thread with union nut, minimum cutout diameter
Material: Polycarbonate UL94VOProtection: IP45
Color: RAL 7032 beige
Dimensions ShipPart No. (Diameter x Depth) Wt. lbs
SDA412 2.6" x 1.2" 1
Packaged individually.Provides for controlled pressurecompensation due to temperaturevariations (i.e. night/day operation).Recommend two plugs per cabinetin opposite locations.Minimum cutout diameter 1.46"
NC - Normally Closed (Red)Used in conjunction with heaters.
Contact opens when risingtemperatures reach the set pointtemperature shutting heater off.
NO - Normally Open (Blue)Used in conjunction with fans.
Contact closes when risingtemperatures reach the set point
temperature turning fan on.
Co
ntro
l Devices
Quality Enclosures. Service Excellence.© Hammond Manufacturing Distributed By Gross Automation 877.268.3700 Data Subject to change without notice
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
375
Clim
ate Con
trol Pro
du
cts