2C-18 EDS Factory Sealed Manual ?!•!;??'• I ^ Motor ... · 1.14 G11 1.25 G12 1.37 G13 1.49 G14...

3
2C-18 EDS Factory Sealed Manual ?!•!;??'• I & r 2 ' G T?r*' c ' D _^ Motor Starting Switches rl !!; & J; ffif >^ DS f and Enclosures ci HI ^•P^ n- n on 4? NEMA 3,7B*CD,9EFG ^^^^ Dimensions Pg. 2C-1 7 With General Electric Switches Maximum HP Ratings 115-230 115 230 Poles Volts AC Volts DC Volts DC Cat. # 1 1 hp 1 hp 1 /4hp CR101-Y 2 1 hp 1 hp 1 hp CR101-H Single Gang Dead Through Hub End Feed Poles Size Cat. # Cat. # 1 3/ 4 EDS21093t EDSC21093t 1 EDS31093t EDSC31093t I 2 3/ 4 EDS21094t EDSC21094t 1 EDS31094f EDSC31094f TWO Gang % EDS22093t EDSC22093t 1 EDS32093t EDSC32093t 3 /4 EDS22094f EDSC22094f 1 EDS32094t EDSC32094f 1With Westinghouse Switches Maximum HP Ratings 120-240 32 120 240 Poles Volts AC Volts DC Volts DC Volts DC Cat. # 1 1 hp 1 /4 hp 1 /4 hp MST01 2 1 hp 1 /4 hp 1 hp 1 hp MST02 Single Gang Dead Through Hub End Feed Poles Size Cat. # Cat. # 1 % EDS21101t EDSC21101t 1 EDS31101t EDSC31101f 2 3/ 4 EDS21102t EDSC21102f 1 EDS31102f EDSC31102t TWO Gang 1 3 /4 EDS22101t EDSC22101t 1 EDS32101t EDSC32101t 3 /4 EDS22102t EDSC22102f 1 EDS32102t EDSC32102f With Alien-Bradley Bulletin 600 Switches Maximum HP Ratings 115-230 115-230 Poles Volts AC Volts DC Cat. # 1 1 hp A-B BUL 600 TOX4 2 1 hp 3/ 4 hp A-B BUL 600 TOX5 Single Gang Dead Through Hub End Feed Poles Size Cat. # Cat. # 1 3/4 EDS2199t EDSC2199t 1 EDS3199t EDSC3199t 2 3/ 4 EDS21100t EDSC21100t 1 EDS31100I EDSC31100t TWO Gang % EDS2299t EDSC2299t Raintight Wet Locations Heater Table (General Electric) Max. Grouse- Motor Hinds Full-Load Symbol Amps Number .48 G2 .53 G3 .58 G4 .65 G5 .71 G6 .78 G7 .86 G8 .95 G9 1.04 G10 1.14 G11 1.25 G12 1.37 G13 1.49 G14 1.63 G15 Max. Grouse- Motor Hinds Full-Load Symbol Amps Number 1.78 G16 1.95 G17 2.13 G18 2.32 G19 2.53 G20 2.76 G21 3.01 G22 3.27 G23 3.56 G24 3.88 G25 4.22 G26 4.60 G27 5.00 G28 5.43 G29 Max. Motor Full-Load Amps 5.90 6.41 6.98 7.60 8.25 8.95 9.75 10.60 11.40 12.50 13.60 14.80 16.00 Grouse- Hinds Symbol Number G30 G31 G32 G33 G34 G35 G36 G37 G38 G39 G40 G41 G42 Heater Table (Westinghouse) Max. Grouse- Motor Hinds Full-Load Symbol Amps Number .43 W1 .48 W2 .53 W3 .58 W4 .64 W5 .71 W6 .78 W7 .87 W8 .95 W9 1.03 W10 1.15 W11 1.27 W12 1.35 W13 Max. Grouse- Motor Hinds Full-Load Symbol Amps Number 1.51 W14 1.67 W15 1.83 W16 1.99 W17 2.23 W18 2.47 W19 2.71 W20 2.95 W21 3.27 W22 3.59 W23 3.99 W24 4.39 W25 4.79 W26 Max. Motor Full-Load Amps 5.26 5.83 6.39 7.03 7.74 8.46 9.35 10.30 11.35 12.47 13.67 15.12 16.00 Grouse- Hinds Symbol Number W27 W28 W29 W30 W31 W32 W33 W34 . W35 W36 W37 W38 W39 Heater Table (Alien Bradley) Max. Grouse- Motor Hinds Full-Load Symbol Amps Number 0.17 P1 0.21 P2 0.25 P3 0.32 P4 0.39 P5 0.46 P6 0.57 P7 0.71 P8 0.79 P9 0.87 P10 0.98 P11 1.08 P12 1.19 P13 Max. Grouse- Motor Hinds Full-Load Symbol Amps Number 1.30 P14 1.43 P15 1.58 P16 1.75 P17 1.88 P18 2.13 P19 2.40 P20 2.58 P21 2.92 P22 3.09 P23 3.32 P24 3.77 P25 4.16 P26 Max. Motor Full-Load Amps 4.51 4.93 5.43 6.03 6.83 7.72 8.24 8.90 9.60 10.80 12.00 13.50 15.20 Grouse- Hinds Symbol Number P27 P28 P29 P30 P31 P32 P33 P34 P35 P36 P37 P38 P39 1 EDS3299t EDSC3299t 3 /4 EDS22100t EDSC22100f 1 EDS32100t EDSC32100t t Includes one interchangeable heater. Select heater from the table below individual listings and use symbol number as second section of the Cat. No. Example: EDS21101-W5. Insert symbol 0 (zero) to omit heater. These heaters are for motors rated 40°C continuously. For motors rated 50°C or 55°C, multiply full load motor current by 0.9 and use this value to select heaters. Symbol 0 (zero) must be used to indicate heater omitted. * Class I, Group B: All units on this page can be modified for Class I, Group B usage. Add suffix GB to the Cat. No. Seals must be installed within 1 1 /fc" of each conduit opening in Division 1. In Canada, for Group B applications consult factory. Copyright" 2000 Cooper Industries, Inc.

Transcript of 2C-18 EDS Factory Sealed Manual ?!•!;??'• I ^ Motor ... · 1.14 G11 1.25 G12 1.37 G13 1.49 G14...

2C-18 EDS Factory Sealed Manual ?!•!;??'• I &r2'GT?r*'c'D_^ Motor Starting Switches rl !!; & J; ffif>^DSf and Enclosures ci HI•̂P^ n- n on 4? NEMA 3,7B*CD,9EFG^^^^ Dimensions Pg. 2C-1 7

With General Electric SwitchesMaximum HP Ratings

115-230 115 230Poles Volts AC Volts DC Volts DC Cat. #1 1 hp 1 hp 1/4hp CR101-Y2 1 hp 1 hp 1 hp CR101-H

Single Gang Dead ThroughHub End Feed

Poles Size Cat. # Cat. #1 3/4 EDS21093t EDSC21093t

• 1 EDS31093t EDSC31093tI 2 3/4 EDS21094t EDSC21094t

1 EDS31094f EDSC31094f

TWO Gang % EDS22093t EDSC22093t1 EDS32093t EDSC32093t

„ 3/4 EDS22094f EDSC22094f1 EDS32094t EDSC32094f

1 With Westinghouse SwitchesMaximum HP Ratings

120-240 32 120 240Poles Volts AC Volts DC Volts DC Volts DC Cat. #1 1 hp 1/4 hp 1/4 hp MST012 1 hp 1/4 hp 1 hp 1 hp MST02

Single Gang Dead ThroughHub End Feed

Poles Size Cat. # Cat. #1 % EDS21101t EDSC21101t

1 EDS31101t EDSC31101f2 3/4 EDS21102t EDSC21102f

1 EDS31102f EDSC31102t

TWO Gang 1 3/4 EDS22101t EDSC22101t

1 EDS32101t EDSC32101t3/4 EDS22102t EDSC22102f1 EDS32102t EDSC32102f

With Alien-Bradley Bulletin 600 SwitchesMaximum HP Ratings

115-230 115-230Poles Volts AC Volts DC Cat. #1 1 hp A-B BUL 600 TOX42 1 hp 3/4 hp A-B BUL 600 TOX5

Single Gang Dead ThroughHub End Feed

Poles Size Cat. # Cat. #1 3/4 EDS2199t EDSC2199t

1 EDS3199t EDSC3199t

2 3/4 EDS21100t EDSC21100t1 EDS31100I EDSC31100t

TWO Gang % EDS2299t EDSC2299t

RaintightWet Locations

Heater Table (General Electric)Max. Grouse-Motor HindsFull-Load SymbolAmps Number

.48 G2

.53 G3

.58 G4

.65 G5

.71 G6

.78 G7

.86 G8

.95 G91.04 G101.14 G111.25 G121.37 G131.49 G141.63 G15

Max. Grouse-Motor HindsFull-Load SymbolAmps Number1.78 G161.95 G172.13 G182.32 G192.53 G202.76 G213.01 G223.27 G233.56 G243.88 G254.22 G264.60 G275.00 G285.43 G29

Max.MotorFull-LoadAmps

5.906.416.987.608.258.959.75

10.6011.4012.5013.6014.8016.00

Grouse-HindsSymbolNumberG30G31G32G33G34G35G36G37G38G39G40G41G42

Heater Table (Westinghouse)Max. Grouse-Motor HindsFull-Load SymbolAmps Number

.43 W1

.48 W2

.53 W3

.58 W4

.64 W5

.71 W6

.78 W7

.87 W8

.95 W91.03 W101.15 W111.27 W121.35 W13

Max. Grouse-Motor HindsFull-Load SymbolAmps Number1.51 W141.67 W151.83 W161.99 W172.23 W182.47 W192.71 W202.95 W213.27 W223.59 W233.99 W244.39 W254.79 W26

Max.MotorFull-LoadAmps

5.265.836.397.037.748.469.35

10.3011.3512.4713.6715.1216.00

Grouse-HindsSymbolNumberW27W28W29W30W31W32W33W34 .W35W36W37W38W39

Heater Table (Alien Bradley)Max. Grouse-Motor HindsFull-Load SymbolAmps Number0.17 P10.21 P20.25 P30.32 P40.39 P50.46 P60.57 P70.71 P80.79 P90.87 P100.98 P111.08 P121.19 P13

Max. Grouse-Motor HindsFull-Load SymbolAmps Number1.30 P141.43 P151.58 P161.75 P171.88 P182.13 P192.40 P202.58 P212.92 P223.09 P233.32 P243.77 P254.16 P26

Max.MotorFull-LoadAmps4.514.935.436.036.837.728.248.909.60

10.8012.0013.5015.20

Grouse-HindsSymbolNumberP27P28P29P30P31P32P33P34P35P36P37P38P39

1 EDS3299t EDSC3299t3/4 EDS22100t EDSC22100f1 EDS32100t EDSC32100t

t Includes one interchangeable heater. Select heater from the table below individual listingsand use symbol number as second section of the Cat. No. Example: EDS21101-W5. Insertsymbol 0 (zero) to omit heater.

These heaters are for motors rated 40°C continuously. For motorsrated 50°C or 55°C, multiply full load motor current by 0.9 and use thisvalue to select heaters. Symbol 0 (zero) must be used to indicateheater omitted.* Class I, Group B: All units on this page can be modified for Class I, Group B usage. Addsuffix GB to the Cat. No. Seals must be installed within 11/fc" of each conduit opening in Division1. In Canada, for Group B applications consult factory.

Copyright" 2000 Cooper Industries, Inc.

EDS Factory Sealed ManualMotor Starting Switches andEnclosures

Cl. I, Div. 1 & 2, Groups B*,C,D ExplosionproofCl. II, Div. 1, Groups E,F,G Dust-lgnitionproofCl. II, Div. 2, Groups F,G RaintightCl. Ill Wet LocationsNEMA3,7B*CD,9EFG

2C-17

EDSC2199 EDS2299

Application: /Factory sealed enclosures are installed in arigid metallic conduit system for^aurfacemounting adjacent to or remote fromequipment being controlled and are used:• to prevent arcing of enclosed device fromcausing ignition of a specific hazardousatmosphere or atmospheres external to theenclosure• in industrial areas such as chemical plants,oil and gas refineries, paint and varnishmanufacturing plants, gasoline bulk loadingterminals, grain elevators, grain processingindustries, coal processing or handling areas,or metal handling or finishing areas whereatmosphere may contain hazardous gasesand/or dust• in non-hazardous areas where sturdy,durable enclosures are required• in conjunction with magnetic starters orcontactors for remote control of motorsManual motor starting switch enclosures areused:• for manual starting of small ac or dc motors• to provide manual starting and stoppingand, in the case of units with heaters, motorrunning protection

Features:Factory sealed devices have many distinctadvantages:• reduce installation problems• eliminate external seals• lower installation costs• improve safety• mounting lugs and taper tapped hubs withintegral bushings• large machine screws for fastening coversto bodies• lockout hole for padlock having W hasp isprovided• close tolerances in machining of wide,mating flanges and journalled shafts andbearings produce flametightness ofenclosure joints• dead end (EDS) or through feed (EDSC)hubs -%" or 1" sizes

Standard Materials:• Bodies - Fera/oy" iron alloy (U.S.); copper-free aluminum (Canada).• Shafts & bushings - stainless steel• Sealing enclosures - copper-free aluminum

Standard Finishes:Feraloy iron alloy - electrogalvanized andaluminum acrylic paint• Copper-free aluminum - natural• Type 6/6 nylon - black• Stainless steel - natural

Certifications andCompliances:• NEC/CEC:

Class I, Division 1 & 2, Groups B*,C,DClass II, Division 1, Groups E,F,GClass II, Division 2, Groups F.GClass III

• NEMA/EEMAC: 3,7B*CD,9EFG• UL Standard: 894, 698• CSA Standard: C22.2 No. 30

Options:Suffix to be

Added toDescription Cat. #For use in Group B hazardous areas. Seals must be installed within 1!£" of each conduitopening in Division 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GB*Bodies and covers (single and two gang units) - copper-free aluminum................... SA

Dimensions (inches) Dimensions are approximate, not for construction purposes.

Side HubView Size% %1 1

-

Dim. Dim. ""h" "i"13/16 ~"1^16

|

h —

k-^r 32 I[TH —— i

InsideDepth2U^I6

S !u — __J

L*iH

T

-.

Front ViewSingle gang jj_ _^ ̂

ii — j |S ^_ 32\ '»S\O^L, r̂15

l ——

32

^ —— tr

\ \pJ

3$~,^J~<L

5

—— i

"

i

*

IV. _

Two gang p — 2 — •

1

._,yi^k'l6^

—— 2 Gang 7-J ——

15

• ̂

•41332

' -1

^-\

k}

Surface covers havesame length and widthas single & 2 gangbodies.

' See Options: suffix GB

Copyright" 2000 Cooper Industries, Inc.

2C-0 Motor StartersApplication and SelectionQuick Selector Chart

Application:Line starters are housed in enclosuressuitable for specific environments, and areused for:• across-the-line starting of motors• motor running protection• undervoltage protection• remote or manual starting and stopping

Selection:Considerations for selection of properenclosure:• The environment of the enclosure locationin accordance with NEC/CEC and NEMA/EEMAC requirements• The characteristics of the starter to beenclosed• See "Quick-Selector" below for guidance

Options:Many options are available on:• material and finishes where specialatmospheric conditions prevail• special features for specific applications.See individual listings for available options,many of which are available in kit form forfield addition to existing units.

Quick Selector ChartEnclosures for Starters

Enclo- NEC/CEC - Hazardoussures Area Compliance

NEMA/EEMACNEMA/ SizeEEMAC StartersEnclosure Starter Single Speed Motor PhaseType Type Non-reversing and Type

ManufacturersEquipmentEnclosed- Starter Cover Type

MC

EPC

EBMS

EMN

EDS,EDSC4

EFD

None

Cl. 1, Div. 1 &2, Groups C,DCl. II, Div. 1, Groups E,F,GCl. II, Div. 2, Groups F,GCl. Ill

Cl. I, Div. 1 & 2, Groups B,C,DCl. II, Div. 1, Groups E,F,GCl. II, Div. 2, Groups F,GCl. Ill

Cl. I, Div. 1 &2, Groups C,DCl. II, Div. 1, Groups E,F,GCl. II, Div. 2, Groups F,GCl. Ill

Cl. I, Div. 1 & 2, Groups B*,C,DCl. II, Div. 1, Groups E,F,GCl. II, Div. 2, Groups F,GCl. Ill

Cl. I, Div. 1 & 2, Groups B,C,DCl. II, Div. 1, Groups E,F,GCl. II, Div. 2, Groups F,GCl. Ill

3,4,12

3,4,7CD,9EFG.12

3,4,7BCD,9EFG.12

3, 7CD,9EFG.12

3.7CD,9EFG.12

3.7BCD,9EFG.12

Manual

Magnetic

Magnetic

Manual

Manual

Manual

0-2

0-5

0-1 P

Single-AC

Poly-AC

Poly-AC

Single andPoly-AC

DC andSingle AC

DC andSingle andPoly-AC

Westinghouse

Alien-BradleyCutler-HammerG.E.Square DWestinghouse

Alien-BradleyG.E.Square DWestinghouse

Alien-BradleyWestinghouseG.E.Square D

Alien-BradleyG.E.Westinghouse

G.E.Square D

Gasketed

Threaded

Bolted/Ground Joint/Gasketed

Bolted/Ground Joint

Bolted/Ground Joint

Bolted/Ground Joint

t Factory sealed units listed on pages 5C-10 and 11.* Check listings for Group B suitability.

Copyright0 2000 Cooper Industries, Inc.