26868 KIN .ps, page 1-2 @ Normalize - Delan AP A4.pdf · 2020. 9. 3. · AirSupply...

3
AP Pneumatic Positioner

Transcript of 26868 KIN .ps, page 1-2 @ Normalize - Delan AP A4.pdf · 2020. 9. 3. · AirSupply...

Page 1: 26868 KIN .ps, page 1-2 @ Normalize - Delan AP A4.pdf · 2020. 9. 3. · AirSupply instrumentquality(dry,clean,oilfree)3.5to 7.0bar,50psito100psistandardconsult Kinetrolforlowpressureapplication

Air Supply instrument quality (dry, clean, oil free) 3.5 to7.0 bar, 50psi to 100psi standard consultKinetrol for low pressure application

Signal 3 – 15psi (0.2 – 1.0 bar) standard consultKinetrol for split range, 6-30psi etc

Control Response 0 – 90° linear output standard consultKinetrol for other characteristic cam options

Sensitivity better than 0.7% of span

Hysteresis better than 0.7% of span

Deviation from linearity less than 1.0% of span

Flowrates AP: 3.3 scfm ( 93 nl/min) @5.5 barMP: 10.0 scfm (283 nl/min) @5.5 barHP: 27.0 scfm (764 nl/min) @5.5 bar

Operating temperature -20° to 80°C standardrange -20° to 100°C High Temperature

Weight 2.8 kg / 6.2 lb

Hazardous area use: Without A/R switchesATEX Cat 1 mechanical approval1G g 90°C

With A/R switchesATEX Cat 11G EExia IIC T4

Key Features• FAST, SMOOTH AND ACCURATE

RESPONSEFrom stepless cam drive and proportionalspool valve.

• UNIVERSAL APPLICATIONMount on any quarter - turn or linearactuator, single or double acting, in anyorientation. Adjustable span may be setanywhere within the 100° range.

• HIGH FLOW / GAIN VERSIONS93 nl/min (3.3 scfm), 283 nl/min (10 scfm)and 764 nl/min(27 scfm) models areavailable.

• INTEGRAL OPTIONS – EASILYRETROFITTED MODULES– two wire 4–20mA angle retransmit insideenclosure– mechanical or inductive position indicationswitches (for general and hazardous areas)in IP65 box– general and hazardous area 4–20mA I/Pconverter modules (intrinsically safe andNEMA 7 explosion proof options available)– high visibility Clear Cone angle monitor onpositioner and switch box versions– DIN plug for external retransmitconnection.– High Temperature seals for 100°Cambient applications.

• SIMPLE, TIME SAVING FIELD SETUPEasy calibration and quick reversal ofrotational sense without special tools oradditional parts. Fast change of responsecharacteristic cams.

• COMPACT AND ROBUST METALHOUSINGWeatherproof sealed and epoxy painted forharsh industrial environments.

• ATEX CATEGORY 1 APPROVALUpto Category 1 approval on most versions,Category 2 approval on some others(Actuators also approved).

• PROVEN FORCE BALANCE SYSTEMEmploying unique straight - linemechanism–minimising wear, backlashand friction. Positioning is unaffected bysupply pressure flutuations.

• VISUAL POSITION INDICATIONExternal pointer / scale or high visibilityClear Cone angle monitor plus internalangle scale for field setup.

• INSTALLATION FLEXIBILITYMount on any actuator using VDI / VDE3845 NAMUR drive, or Kinetrol malesquare,with mounting brackets, or directmount ( with integral porting) to Kinetrolactuators.

• VIBRATION AND SHOCK RESISTANTLow mass spool and robust mechanismprovide 4G / 1OOHz industrial vibrationtolerance in any attitude.

• ADAPTATIONS AND ACCESSORIESConsult Kinetrol for:– split range or customized cams– special failure modes eg fail-freeze– filters, regulators and gauges– mounting kits for rotary / linear drives.

AP Pneumatic PositionerDIMENSIONS

SPECIFICATION

AP Positioner shown direct mounted on a Kinetrol 07 Actuator

NAMUR Discrete Version

Kinetrol Discrete High Flow Version

Kinetrol Non-Hazardous I/P

Materials case and cover - zinc alloyspool and liner - stainless steeldiaphragm - polyester reinforced-polyurethane or High Temperaturefeedback spring - steel

Finish epoxy stove enamel

Enclosure rating IP54

Output torque same as double acting or spring returnactuator when controlling fast movement ofinertia loads consult Kinetrol

Vibration tolerance 4G, 100Hz

I/P converter options Non - hazardousSupply pressure 4 – 5.5 bar (60 – 80 psi)

ATEX EEx d IIC T6EEX ia IIC T4/T5/T6

FM Class I Division 1explosion proof Groups B,C,Dintrinsically safe Groups A,B,C,D,E.F,G

CSA Class I Division 1explosion proof Groups B,C,Gintrinsically safe Groups A,B,C,D

AP Pneumatic PositionerThe policy of KINETROL is one of continuous improvement. We reserve the right to alter the product as described and illustrated without notice.

Kinetrol Ltd, Trading Estate, Farnham, Surrey GU9 9NU, EnglandTelephone: 01252 733838 Fax: 01252 713042

e-mail: [email protected] 391 07/04

Note: When drawing information is not given - it is the same as basic version.

Explosion Proof I/P Version Switch Box Version

Page 2: 26868 KIN .ps, page 1-2 @ Normalize - Delan AP A4.pdf · 2020. 9. 3. · AirSupply instrumentquality(dry,clean,oilfree)3.5to 7.0bar,50psito100psistandardconsult Kinetrolforlowpressureapplication

The

AP

pneu

mat

icpo

sitio

ner

com

bine

sth

esm

ooth

ness

and

accu

racy

ofK

inet

rol’s

prov

enm

echa

nica

lpos

tione

rte

chno

logy

(usi

nga

prop

ortio

nals

pool

valv

edr

iven

bya

sim

ple,

accu

rate

and

robu

stfo

rce

bala

nce

mec

hani

sm)

with

new

adva

nces

inco

nven

ienc

ean

dsi

mpl

icity

ofus

e,de

rived

from

the

uniq

uein

nova

tive

desi

gnbo

thof

the

inte

rnal

mec

hani

sman

dof

the

over

allp

acka

ge.

The

resu

ltis

apo

sitio

ner

with

unpa

ralle

led

perf

orm

ance

and

real

indu

stria

lro

bust

ness

,sw

eet

and

easy

toca

libra

tean

dch

arac

teriz

e,an

dad

apta

ble

toth

ew

hole

rang

eof

appl

icat

ions

with

itsun

beat

able

list

ofop

tions

–hi

ghflo

wva

lves

,di

rect

mou

ntor

indu

stry

stan

dard

disc

rete

mou

ntho

usin

gs,

4-20

mA

angl

ere

tran

smit,

limit

switc

hes,

Cle

arC

one

posi

tion

mon

itor

and

I/Pco

nver

tors

(eith

ersi

mpl

eor

with

vario

usex

plos

ion

proo

fop

tions

).

AIR

FLO

WC

HA

NG

EO

VE

RB

LOC

K–

allo

ws

sele

ctio

nof

dire

ctio

nin

whi

chpo

sitio

ner

mov

es(f

ordi

rect

mou

ntm

odel

s).

APPneumaticPositioner

LID

–sh

own

with

optio

nalC

lear

Con

ese

aled

angl

em

onito

r.E

poxy

coat

eddi

e–ca

stm

etal

held

onby

four

capt

ive

scre

ws

give

squ

ick

acce

ssto

the

inte

rior.

SP

OO

LV

ALV

E–

high

lyre

liabl

e,al

lmet

al,

5po

rtpr

opor

tiona

lva

lve

cont

rols

the

air

flow

.T

hree

vers

ions

,w

ithdi

ffere

ntflo

wra

tes,

are

easi

lyin

terc

hang

able

.

INT

ER

CH

AN

GE

AB

LEP

OR

TP

LAT

ES

–ea

sily

conv

ertib

lefo

rdi

ffere

ntflo

wra

teop

tions

.

3–T

ER

MIN

AL

DIN

PLU

G–

retr

ofita

ble

optio

nav

aila

ble

for

4-20

mA

angl

ere

tran

smit.

Allo

ws

fully

exte

rnal

conn

ectio

nw

ithra

pid

conn

ect/d

isco

nnec

tca

pabi

lity.

GA

UG

EP

OR

T–

asst

anda

rd.

EX

HA

US

TS

NU

BB

ER

SC

RE

WS

–al

low

trav

elsp

eed

redu

ctio

ndo

wn

to1 /

3x

full

spee

d,in

depe

nden

tlyin

each

dire

ctio

n,by

scre

win

gin

tore

stric

tex

haus

tai

rflo

w.

INT

ER

NA

LA

NG

LES

CA

LE–

with

adju

stab

lein

dica

tor

for

easy

field

calib

ratio

n.

SPA

NA

DJU

ST

ME

NT

–qu

ick

and

easy

thum

bwhe

else

tting

with

slot

ted

lock

ing

scre

w.

UN

ITID

EN

TIF

ICAT

ION

–ea

chpo

sitio

ner

carr

ies

aun

ique

seria

lnu

mbe

ran

dis

CE

mar

ked.

ZE

RO

AD

JUS

TM

EN

T–

quic

kan

dea

syth

umbw

heel

setti

ngw

ithsl

otte

dlo

ckin

gsc

rew

.

ST

RA

IGH

T–L

INE

ME

CH

AN

ISM

–un

ique

geom

etry

allo

ws

cw/c

cwch

ange

over

bysi

mpl

eca

min

vers

ion.

FE

ED

BA

CK

PO

TD

RIV

E–

zero

back

lash

,pr

oven

trou

ble

free

for

life.

OP

TIO

NA

LA

NG

LER

ET

RA

NS

MIT

CIR

CU

IT–

exte

rnal

lypo

wer

ed(8

–30v

DC

)lin

ear

4-20

mA

feed

back

,ra

ngab

ledo

wn

to30

ºfo

rfu

ll4-

20m

Asp

an.E

asily

acce

ssib

leze

roan

dsp

anad

just

men

t.

RE

TR

AN

SM

ITP

OT

–hi

ghqu

ality

cond

uctiv

epl

astic

serv

o–ty

pew

ithba

llbe

arin

gs.P

rove

nlo

nglif

ean

dhi

ghpr

ecis

ion.

FE

ED

BA

CK

SH

AF

T–

inno

vativ

eco

llet

conn

ectio

npe

rmits

quic

k–fit

/rel

ease

ofth

eac

tuat

orin

terf

ace

and

elim

inat

esba

ckla

sh.

FE

ED

BA

CK

CA

M–

quic

kan

dea

syre

vers

al(

for

rota

tiona

lse

nse

hand

ing)

orre

plac

emen

t(t

och

ange

the

resp

onse

char

acte

ristic

)of

the

cam

isfa

cilit

ated

bya

sprin

glo

aded

rete

ntio

nde

vice

.

AC

TU

ATO

RIN

TE

RFA

CE

–op

tions

incl

ude

NA

MU

Rst

anda

rd(s

how

n),

Kin

etro

lm

ale

squa

reor

Kin

etro

ldi

rect

mou

ntfe

mal

esq

uare

.Qui

ckex

tern

alco

nver

sion

allo

ws

brac

ket

mou

ntin

gto

any

rota

ryor

linea

rac

tuat

or.

SE

ALI

NG

CA

P

OPERATING

PRINCIPLES

•T

heA

Ppo

sitio

ner

isde

sign

edto

driv

ea

rota

ryor

linea

rac

tuat

orto

apo

sitio

nse

tby

a3-

15ps

i(0.

2-

1.0

bar)

sign

alan

dho

ldit

ther

eun

tilth

esi

gnal

chan

ges.

•W

hen

asi

gnal

pres

sure

isap

plie

dto

the

diap

hrag

mit

mov

esth

efo

rce

bala

nce

leve

rcl

ockw

ise

agai

nst

the

tens

ion

ofth

efe

edba

cksp

ring.

Thi

sm

oves

the

spoo

lval

ve,

supp

lyin

gai

rpr

essu

reto

one

side

ofth

eac

tuat

orw

hile

exha

ustin

gtr

appe

dai

rfr

omth

eot

her

side

.The

feed

back

shaf

tfo

llow

sth

em

ovem

ent

ofth

eac

tuat

oran

dtu

rns

the

cam

coun

ter

cloc

kwis

e,pu

shin

gth

eca

mfo

llow

eran

din

crea

sing

the

tens

ion

onth

efe

edba

cksp

ring

until

itba

lanc

esth

efo

rce

onth

edi

aphr

agm

and

mov

esth

esp

oolv

alve

toits

cent

ral‘

hold

’pos

ition

.

•T

here

latio

nshi

pbe

twee

nth

ein

put

sign

alan

dde

sire

dpo

sitio

n(t

he‘c

hara

cter

istic

’)is

dete

rmin

edby

the

cam

prof

ile.A

linea

r3-

15ps

i(0.

2-

1.0

bar)

sign

al/

0-90

°ou

tput

mov

emen

tca

mis

stan

dard

.Spl

itra

nge,

fast

open

ing,

equa

lper

cent

age

orcu

stom

ized

char

acte

ristic

cam

sar

eav

aila

ble.

CA

RR

IER

PLA

TE

AS

SE

MB

LIE

S–

inte

grat

edas

sem

blie

sca

rryi

ngth

efe

edba

cksh

aft

and

cam

plus

angl

ere

tran

smit

driv

ean

dpo

t(w

hen

spec

ified

).E

asily

rem

oved

for

conv

ersi

onor

mai

nten

ance

.

EN

CLO

SU

RE

–ro

bust

die-

cast

met

alw

ithto

ugh

corr

osio

n-re

sist

ant

epox

yco

atin

gan

dO

-rin

gse

alin

g.La

yout

give

sea

syac

cess

toal

ladj

ustm

ents

onre

mov

alof

lid.

ORDERINGCO

DES

SCHEMATICFUNCTIONAL

DIAG

RAM

Page 3: 26868 KIN .ps, page 1-2 @ Normalize - Delan AP A4.pdf · 2020. 9. 3. · AirSupply instrumentquality(dry,clean,oilfree)3.5to 7.0bar,50psito100psistandardconsult Kinetrolforlowpressureapplication

Air Supply instrument quality (dry, clean, oil free) 3.5 to7.0 bar, 50psi to 100psi standard consultKinetrol for low pressure application

Signal 3 – 15psi (0.2 – 1.0 bar) standard consultKinetrol for split range, 6-30psi etc

Control Response 0 – 90° linear output standard consultKinetrol for other characteristic cam options

Sensitivity better than 0.7% of span

Hysteresis better than 0.7% of span

Deviation from linearity less than 1.0% of span

Flowrates AP: 3.3 scfm ( 93 nl/min) @5.5 barMP: 10.0 scfm (283 nl/min) @5.5 barHP: 27.0 scfm (764 nl/min) @5.5 bar

Operating temperature -20° to 80°C standardrange -20° to 100°C High Temperature

Weight 2.8 kg / 6.2 lb

Hazardous area use: Without A/R switchesATEX Cat 1 mechanical approval1G g 90°C

With A/R switchesATEX Cat 11G EExia IIC T4

Key Features• FAST, SMOOTH AND ACCURATE

RESPONSEFrom stepless cam drive and proportionalspool valve.

• UNIVERSAL APPLICATIONMount on any quarter - turn or linearactuator, single or double acting, in anyorientation. Adjustable span may be setanywhere within the 100° range.

• HIGH FLOW / GAIN VERSIONS93 nl/min (3.3 scfm), 283 nl/min (10 scfm)and 764 nl/min(27 scfm) models areavailable.

• INTEGRAL OPTIONS – EASILYRETROFITTED MODULES– two wire 4–20mA angle retransmit insideenclosure– mechanical or inductive position indicationswitches (for general and hazardous areas)in IP65 box– general and hazardous area 4–20mA I/Pconverter modules (intrinsically safe andNEMA 7 explosion proof options available)– high visibility Clear Cone angle monitor onpositioner and switch box versions– DIN plug for external retransmitconnection.– High Temperature seals for 100°Cambient applications.

• SIMPLE, TIME SAVING FIELD SETUPEasy calibration and quick reversal ofrotational sense without special tools oradditional parts. Fast change of responsecharacteristic cams.

• COMPACT AND ROBUST METALHOUSINGWeatherproof sealed and epoxy painted forharsh industrial environments.

• ATEX CATEGORY 1 APPROVALUpto Category 1 approval on most versions,Category 2 approval on some others(Actuators also approved).

• PROVEN FORCE BALANCE SYSTEMEmploying unique straight - linemechanism–minimising wear, backlashand friction. Positioning is unaffected bysupply pressure flutuations.

• VISUAL POSITION INDICATIONExternal pointer / scale or high visibilityClear Cone angle monitor plus internalangle scale for field setup.

• INSTALLATION FLEXIBILITYMount on any actuator using VDI / VDE3845 NAMUR drive, or Kinetrol malesquare,with mounting brackets, or directmount ( with integral porting) to Kinetrolactuators.

• VIBRATION AND SHOCK RESISTANTLow mass spool and robust mechanismprovide 4G / 1OOHz industrial vibrationtolerance in any attitude.

• ADAPTATIONS AND ACCESSORIESConsult Kinetrol for:– split range or customized cams– special failure modes eg fail-freeze– filters, regulators and gauges– mounting kits for rotary / linear drives.

AP Pneumatic PositionerDIMENSIONS

SPECIFICATION

AP Positioner shown direct mounted on a Kinetrol 07 Actuator

NAMUR Discrete Version

Kinetrol Discrete High Flow Version

Kinetrol Non-Hazardous I/P

Materials case and cover - zinc alloyspool and liner - stainless steeldiaphragm - polyester reinforced-polyurethane or High Temperaturefeedback spring - steel

Finish epoxy stove enamel

Enclosure rating IP54

Output torque same as double acting or spring returnactuator when controlling fast movement ofinertia loads consult Kinetrol

Vibration tolerance 4G, 100Hz

I/P converter options Non - hazardousSupply pressure 4 – 5.5 bar (60 – 80 psi)

ATEX EEx d IIC T6EEX ia IIC T4/T5/T6

FM Class I Division 1explosion proof Groups B,C,Dintrinsically safe Groups A,B,C,D,E.F,G

CSA Class I Division 1explosion proof Groups B,C,Gintrinsically safe Groups A,B,C,D

AP Pneumatic PositionerThe policy of KINETROL is one of continuous improvement. We reserve the right to alter the product as described and illustrated without notice.

Kinetrol Ltd, Trading Estate, Farnham, Surrey GU9 9NU, EnglandTelephone: 01252 733838 Fax: 01252 713042

e-mail: [email protected] 391 07/04

Note: When drawing information is not given - it is the same as basic version.

Explosion Proof I/P Version Switch Box Version