24010, 3/2 Direct solenoid actuated poppet valvecdn.norgren.com/pdf/en_5_4_309_24010.pdf4,5 15 13,5...

7
02/18 en 5.4.309.01 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2004 - 5125i) © 2015 Norgren GmbH 24010, 3/2 Direct solenoid actuated poppet valve Technical features > 1/4” (G or NPT) Inline & NAMUR > Main application: Single acting actuators in intrinsically safe circuits > Approval according to IEC 61508, multichannel up to SIL 3 > Solenoid valve with low power consumption > High operational reliability even after long periods of non- operation > Suited for outdoor use under critical environment conditions > Universal flow direction Technical data Housing: Brass, seals: NBR -25 ... +80°C (-13 ... +176°F) Symbol Port size Operating pressure (bar) Manual override Test certificate IEC 61508 Weight (kg) Drawing No. Model 2 13 1/4 NPT 0 ... 10 Not possible X 0,65 1 2401087200400000 G1/4 0 ... 10 Not possible X 0,65 1 2401088200400000 Housing: Stainless steel, seals: NBR -25 ... +80°C (-13 ... +176°F) Symbol Port size Operating pressure (bar) Manual override Test certificate IEC 61508 Weight (kg) Drawing No. Model 2 13 1/4 NPT 0 ... 10 Not possible X 0,65 2 2401012200400000 G1/4 0 ... 10 Not possible X 0,65 2 2401086200400000 Housing: Aluminium anodized, seals: NBR -25 ... +80°C (-13 ... +176°F) Symbol Port size Operating pressure (bar) Manual override Test certificate IEC 61 508 Weight (kg) Drawing No. Model 2 2 1 12 3 3 G1/4 NAMUR 0 ... 10 Retrofittable X 0,55 3 2401091200400000 1/4 NPT NAMUR 0 ... 10 Retrofittable X 0,55 3 2401090200400000 2 2 11 12 3 3 G1/4 NAMUR 0 ... 10 Retrofittable X 0,55 4 2401009200400000 *1) *1) Port 1 in flange according to VDI/VDE 3845 for attachment of positioners or to interlinking plate (see data sheet 5.4.830) Medium: Neutral or aggressive, gaseous fluids which do not damage the product or affect the function (e.g. compressed air, nitrogen). Based on ISO 8573-1-2010 classification 1-2-3. Operation: Direct solenoid operated poppet valve Operating pressure: 0 ... 10 bar (0 ... 145 psi) Orifice: 5 mm Flow: Gaseous fluids: 375 l/min Liquid fluids: Kv 0,34 Port size: G1/4, 1/4 NPT, G1/4 NAMUR or 1/4 NPT NAMUR NAMUR Interface with integrated recirculation from the exhaust air to the acutator spring chamber Flow direction: Universal Mounting position: Any, but preferably with solenoid vertical Ambient/Media temperature: -25 ... +80°C (-13 ... +176°F) Depending on solenoid system. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (35°F). For outdoor installations all con- nections must be protected against the penetration of moisture and a solenoid with IP66 protection must be used! Materials: Body: Aluminium anodized (suitable for high humidity, sulphuric, sodium chloride or ammonia environments), brass 2.0401, stainless steel 1.4404 (316 L) Inner parts: Stainless steel, brass Solenoid housing: Aluminium anodized Seals: NBR Further versions: On request Flow conversion: Cv US Gallon/min (water) = l/min (air) x 0,001 Kv m³/h (water) = l/min (air) x 0,000906

Transcript of 24010, 3/2 Direct solenoid actuated poppet valvecdn.norgren.com/pdf/en_5_4_309_24010.pdf4,5 15 13,5...

Page 1: 24010, 3/2 Direct solenoid actuated poppet valvecdn.norgren.com/pdf/en_5_4_309_24010.pdf4,5 15 13,5 5,5 19 G1/4 4 22 7,5 122 29 M5 26,5 70,5 50 113 108 1 ~ 2 1 ø 15,5 G1/4 ø 19,5

02/18en 5.4.309.01

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2004 - 5125i) © 2015 Norgren GmbH

24010, 3/2 Direct solenoid actuated poppet valve

Technical features

> 1/4” (G or NPT) Inline & NAMUR

> Main application: Single acting actuators in intrinsically safe circuits

> Approval according to IEC 61508, multichannel up to SIL 3

> Solenoid valve with low power consumption

> High operational reliability even after long periods of non- operation

> Suited for outdoor use under critical environment conditions

> Universal flow direction

Technical data Housing: Brass, seals: NBR -25 ... +80°C (-13 ... +176°F)Symbol Port size Operating

pressure (bar)Manual override

Test certificateIEC 61508

Weight(kg)

DrawingNo.

Model

2

1 3

1/4 NPT 0 ... 10 Not possible X 0,65 1 2401087200400000

G1/4 0 ... 10 Not possible X 0,65 1 2401088200400000

Housing: Stainless steel, seals: NBR -25 ... +80°C (-13 ... +176°F)Symbol Port size Operating

pressure (bar)Manual override

Test certificateIEC 61508

Weight(kg)

DrawingNo.

Model

2

1 3

1/4 NPT 0 ... 10 Not possible X 0,65 2 2401012200400000

G1/4 0 ... 10 Not possible X 0,65 2 2401086200400000

Housing: Aluminium anodized, seals: NBR -25 ... +80°C (-13 ... +176°F)Symbol Port size Operating

pressure (bar)Manual override

Test certificateIEC 61 508

Weight(kg)

DrawingNo.

Model

2

21

12

3

3

G1/4 NAMUR 0 ... 10 Retrofittable X 0,55 3 2401091200400000

1/4 NPT NAMUR 0 ... 10 Retrofittable X 0,55 3 2401090200400000

2

21 1

12

3

3

G1/4 NAMUR 0 ... 10 Retrofittable X 0,55 4 2401009200400000 *1)

*1) Port 1 in flange according to VDI/VDE 3845 for attachment of positioners or to interlinking plate (see data sheet 5.4.830)

Medium:Neutral or aggressive, gaseous fluids which do not damage the product or affect the function (e.g. compressed air, nitrogen). Based on ISO 8573-1-2010 classification 1-2-3.Operation:Direct solenoid operated poppet valveOperating pressure:0 ... 10 bar (0 ... 145 psi)Orifice:5 mm

Flow:Gaseous fluids: 375 l/minLiquid fluids: Kv 0,34Port size:G1/4, 1/4 NPT, G1/4 NAMUR or 1/4 NPT NAMURNAMUR Interface with integrated recirculation from the exhaust air to the acutator spring chamberFlow direction:UniversalMounting position:Any, but preferably withsolenoid vertical

Ambient/Media temperature:-25 ... +80°C (-13 ... +176°F) Depending on solenoid system. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (35°F).For outdoor installations all con-nections must be protected against the penetration of moisture and a solenoid with IP66 protection must be used!

Materials:Body: Aluminium anodized(suitable for high humidity, sulphuric, sodium chloride or ammonia environments),brass 2.0401,stainless steel 1.4404 (316 L) Inner parts: Stainless steel, brassSolenoid housing: Aluminium anodizedSeals: NBRFurther versions:On requestFlow conversion:Cv US Gallon/min (water) = l/min (air) x 0,001Kv m³/h (water) =l/min (air) x 0,000906

Page 2: 24010, 3/2 Direct solenoid actuated poppet valvecdn.norgren.com/pdf/en_5_4_309_24010.pdf4,5 15 13,5 5,5 19 G1/4 4 22 7,5 122 29 M5 26,5 70,5 50 113 108 1 ~ 2 1 ø 15,5 G1/4 ø 19,5

24010, 3/2 Direct solenoid actuated poppet valve

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2004 - 5125i) © 2015 Norgren GmbHen 5.4.309.02

02/18

Function of solenoid drive To switch the direct operated valve, a certain energy is required. This energy is stored in a capacitor. The charging voltage is 17 V. The higher the supply voltage, the shorter the charging time. As soon as the charging voltage has been reached, the valve switches. The small current now flowing through the coil is sufficient to hold the valve in the open position. At least 40 mA are required for this.

Current supply units: When selecting an intrinsically safe power supply, it is important to observe the maximum permissible values acc. to the EU-Type-Examination Certificate EPS 16 ATEX 1 001 respectively IECEx EPS 16.0001 Ui 28 V, li 110 mA, Pi 1,5 W. The effective internal capacities Ci; and inductivities li of the solenoid are negligible low.

Operating sequence ApprovalsModel Approvals

ATEX IECEx

2004 EPS 16 ATEX 1 001 IECEx EPS 16.0001

Item numbers for international approvalsCountry/Approvals Solenoid series/

Code2004

Europe/ATEX Standard x

International/IECEx Standard x

China/NEPSI -01 -

Brasil/INMETRO -02 -

Korea/KOSHA -03 -

Russia, Kazakhstan & Belarus/TR-CU 012 -04 x

India/CCOE Standard x

Taiwan/ITRI Standard -

Example: 0000000200400000-04 (Solenoid: 2004; Approval: TR-CU 012)

Solenoid parameters for use in intrinsically safe circuits

Switch-onvoltage

Holdingcurrent

Holdingvoltage

Pick-up delay typical *2)

Protectionclass IP

Ex-Protection(ATEX-Category)

TemperatureAmbient/Fluid

Weight Model

(V) (mA) (V) (s) (°C) (kg)

17 ... 28 > 40 ~ 5 2 ... 5 IP66 with cable gland (cable Ø 5 ... 10 mm) is in scope of delivery

II 2G Ex ia IIC T5/T6 Gb

II 2D Ex ia IIIC T95°C Db

T5: –40 ... +70T6: –40 ... +55–40 ... +70

0,85 2004

*2) Depending on intrinsically current supply

Solenoid parameters for use in non harardous locations

Switch-onvoltage

Current con- sumption

Holdingcurrent

Powerconsumption

Pick-up delaytypical *2)

Protectionclass IP

Ex-Protection(ATEX-Category)

TemperatureAmbient/Fluid

Weight Model

(V) (mA) (mA) (W) (s) (°C) (kg)

18 ... 28 62 > 40 1,5 at 24 V 3 IP66 with cable gland (cable Ø 5 ... 10 mm) is in scope of delivery

– –40 ... +80 0,85 2004

Control signal Valve control module

≥ 40 mA

t

t

t

ON

OFF

tON

Input current magnet

Switch state valve

Circuit diagram

Page 3: 24010, 3/2 Direct solenoid actuated poppet valvecdn.norgren.com/pdf/en_5_4_309_24010.pdf4,5 15 13,5 5,5 19 G1/4 4 22 7,5 122 29 M5 26,5 70,5 50 113 108 1 ~ 2 1 ø 15,5 G1/4 ø 19,5

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2004 - 5125i) © 2015 Norgren GmbH

24010, 3/2 Direct solenoid actuated poppet valve

en 5.4.309.0302/18

Manual OverrideThe manual override is meant to be used for system testing. The valve switches back into normal position when deenergized.

Accessories

Silencer (plastic) *3)

Silencer (stainless steel) *3)

Silencer (brass) *3)

Exhaust guard *4) Add-on manual override (without detent) (with detent)

Page 6 Page 6 Page 6 Page 6 Page 5 Page 5

C/S2 (1/4 NPT) 0014613 (G1/4) T40C2800 (G1/4) 0613422 (G1/4, 1/4 NPT) 0600205 0601765

M/S2 (G1/4) 0613678 (1/4 NPT) MS002A (1/4 NPT)

*3) For indoors use *4) For outdoors use, opening pressure ~ 0,2 bar Using the manual override with detent cancels the SIL-Approval!

NAMUR accessories (only G1/4)

Throttle control plate *5) Flange plate Yoke Mounting plate Quick exhaust module *6)

Page 7 Page 7 Page 7 Page 7 Page 7

4040239 0612790 (NAMUR single connection plate)

0540593 (Pipe mounting use in combination with 0612790)

0613453 (90°) 4050218

0612791 (NAMUR-rip use in combination with 0612790)

*5) The throttle control plate 4040239 has a minimum flow rate for safety reason. *6) Technical details see catalogue page 5.4.820

Page 4: 24010, 3/2 Direct solenoid actuated poppet valvecdn.norgren.com/pdf/en_5_4_309_24010.pdf4,5 15 13,5 5,5 19 G1/4 4 22 7,5 122 29 M5 26,5 70,5 50 113 108 1 ~ 2 1 ø 15,5 G1/4 ø 19,5

1

1212

30,55,5

27

55

12

3

~

12,5

35,551

102

108

70,5

122

29

3

12

70,5

12,5

35,551

102

108

5,5

27

55

1212

301

~

122

29

24010, 3/2 Direct solenoid actuated poppet valve

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2004 - 5125i) © 2015 Norgren GmbHen 5.4.309.04

02/18

DimensionsValves

1

2

1 Port size G1/4 or 1/4 NPT

Dimensions in mm Projection/First angle

Page 5: 24010, 3/2 Direct solenoid actuated poppet valvecdn.norgren.com/pdf/en_5_4_309_24010.pdf4,5 15 13,5 5,5 19 G1/4 4 22 7,5 122 29 M5 26,5 70,5 50 113 108 1 ~ 2 1 ø 15,5 G1/4 ø 19,5

1

ø 1

5,5

19

G 1

/4

G1/

4

ø 19

,5

16

17

50

37,5

33

22

22,5

326,5

6,5

52

12

24

4,5

13,5

5,5

15

19

G1/4

4

22

7,5

122

29

M5

26,5

70,5

50

10811

3

1

~

2

1

ø 1

5,5

G1/

4

ø 19

,516

17

50

37,5

33

212

22,5

326,5

6,5

52

12

24

13,5

5,5

15

19

G1/4

4

22

7,5

122

29

1,5

M5

ø10 M6

26,5

70,5

50

10811

3

1

4,5

~

2

4,5

8,5

ø12

19

9,5

9

36

19

1

ø 1

5,5

G1/

4

ø 19

,516

17

50

37,5

33

212

22,5

326,5

6,5

52

12

24

13,5

5,5

15

19

G1/4

4

22

7,5

122

29

1,5

M5

ø10 M6

26,5

70,5

50

10811

3

1

4,5

~

2

1

ø 1

5,5

19

G 1

/4

G1/

4

ø 19

,5

16

17

50

37,5

33

22

22,5

326,5

6,5

52

12

24

4,5

13,5

5,5

15

19

G1/4

4

22

7,5

122

29

M5

26,5

70,5

50

10811

3

1

~

2

4,5

8,5

ø12

19

9,5

9

36

19

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2004 - 5125i) © 2015 Norgren GmbH

24010, 3/2 Direct solenoid actuated poppet valve

en 5.4.309.0502/18

3

Please note: add-on manual override for NAMUR valves provided only for commissioning and tests

1 Port size G1/4 or 1/4 NPT 2 3 mm deep

Dimensions in mm Projection/First angle

Add-on manual overrideWithout detent Model: 0600205

With detent Model: 0601765

4

Page 6: 24010, 3/2 Direct solenoid actuated poppet valvecdn.norgren.com/pdf/en_5_4_309_24010.pdf4,5 15 13,5 5,5 19 G1/4 4 22 7,5 122 29 M5 26,5 70,5 50 113 108 1 ~ 2 1 ø 15,5 G1/4 ø 19,5

M5

32

2

24

3 (4)

2

1

26,5

10

ø 2

1

1/4”

19

12 12

34,5

104

2127ø 9

ø 14,5

25,5 M5 (4x)

41

25,5

1616

11,5

19

1012

29

35

3019

60

ø 5,5

ø 9,5

G1/4

19

G1/

4

19

3 (4)

2

2 3 (4)

41

60°

11

51

9,5

512

5,5

5,5

ø D

C

G

B

C

G

B

24010, 3/2 Direct solenoid actuated poppet valve

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2004 - 5125i) © 2015 Norgren GmbHen 5.4.309.06

02/18

1 Coding stud threaded 2 8 mm deep

Dimensions in mm Projection/First angle

Accessories

Model: 0613422Exhaust guard

NAMUR quick exhaust module for a better kv-value by exhaust see data sheet 5.4.820

NAMUR interlinking plates in redundancy design for »safety exhausting« and »safety ventilating« see data sheet 5.4.830

Silencer

B G C Ø D Weight (g) Model

G1/4 7 35,5 15,5 2,9 M/S2

1/4 NPT 7 35,5 15,5 2,9 C/S2

B C G Weight (g) Model

G1/4 33 8 17 18 T40C2800

1/4 NPT 35 8 9/16” 18 MS002A

G1/4 36 8 16 23 0014613

1/4 NPT 36 8 17 67 0613678

Silencer Model:plastic: M/S2, C/S2

Model: brass: T40C2800, MS002Astainless steel: 0014613, 0613678

NAMUR hole pattern (actuator side)

Single connection plateModel: 0612790

NAMUR ripModel: 0612791

Page 7: 24010, 3/2 Direct solenoid actuated poppet valvecdn.norgren.com/pdf/en_5_4_309_24010.pdf4,5 15 13,5 5,5 19 G1/4 4 22 7,5 122 29 M5 26,5 70,5 50 113 108 1 ~ 2 1 ø 15,5 G1/4 ø 19,5

205

12

65

2x

50

M5

41

2 2

1 1

32

15,5

4512

12

19,5

76 4

M 5

87,

5

25

15,5

15,5

3

21

12

3 2

1

12

1224

12

9

32

16

20

16

43,555

55

32

2024

12

M5

7

3

21

3

24

G1/8 8

27.5

32

551.3

~ 33

7.5

30

3

21

M5

12

2442

80

ø 5

.5

G1/

4 43

M5

G3/

8

ø 1

5.5

ø 1

9.5

M5

1 2

3

4

5

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2004 - 5125i) © 2015 Norgren GmbH

24010, 3/2 Direct solenoid actuated poppet valve

en 5.4.309.0702/18

Yoke Throttle control plateModel: 0540593 Model: 4040239

Dimensions in mm Projection/First angle

90° Mounting plateModel: 0613453

1 Flanged surface NAMUR or externally mounted valve2 Flanged surface NAMUR actuator3 Push-in threaded piece after plate mounting

(to secure correct position)4 8 mm deep5 Flow regulator retrofittable

Quick exhaust module Typ: 4050218

Warning

These products are intended for use in industrial compressed air and fluid systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult IMI Precision Engineering, Norgren GmbH.

Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.

Functional safety (SIL):

Suitable for certain applications can only be evaluated through examina-tion of each safety-related overall system with regard to the requirements of IEC 61508/61511.

EN - Englisch